| 1 | 1 | Civil Work Items 1 to 33\nDemolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. HSR 5.7 \n5.7.4 In cement mortar | BI01010001010000000000000515BI0100001113 | 11.78 | cum |
|---|
| 2 | 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : HSR 5.29 \n5.29.1 Of area 3 sq. metres and below | BI01010001010000000000000515BI0100001114 | 16 | each |
|---|
| 3 | 3 | 5.29.2 Of area beyond 3 sq. metres | BI01010001010000000000000515BI0100001115 | 31 | each |
|---|
| 4 | 4 | Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. HSR 5.42 | BI01010001010000000000000515BI0100001116 | 130.79 | sqm |
|---|
| 5 | 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. HSR 5.43 \n5.43.1 For thickness of tiles 10 mm to 25 mm | BI01010001010000000000000515BI0100001117 | 153.56 | sqm |
|---|
| 6 | 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. HSR 5.45 | BI01010001010000000000000515BI0100001118 | 119.1 | sqm |
|---|
| 7 | 7 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. HSR 5.70 | BI01010001010000000000000515BI0100001119 | 18.97 | cum |
|---|
| 8 | 8 | Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : HSR 7.22\n7.22.2 Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001120 | 1.58 | cum |
|---|
| 9 | 9 | Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. HSR 7.28\n7.28.2 Cement mortar 1:4 (1 cement :4 coarse sand) | BI01010001010000000000000515BI0100001121 | 14.17 | sqm |
|---|
| 10 | 10 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : HSR 9.17\n9.17.1 In 75x75 mm deep chase | BI01010001010000000000000515BI0100001122 | 69.98 | Metre |
|---|
| 11 | 11 | Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 HSR 10.7 | BI01010001010000000000000515BI0100001123 | 10 | sqm |
|---|
| 12 | 12 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 10.50\n10.50.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. | BI01010001010000000000000515BI0100001124 | 65.66 | sqm |
|---|
| 13 | 13 | Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. HSR 10.52\n10.52.1 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. | BI01010001010000000000000515BI0100001125 | 153.56 | sqm |
|---|
| 14 | 14 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 | BI01010001010000000000000515BI0100001126 | 150.13 | sqm |
|---|
| 15 | 15 | Providing and laying 50mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. HSR 10.75 | BI01010001010000000000000515BI0100001127 | 130.79 | sqm |
|---|
| 16 | 16 | 15 mm cement plaster on the rough side of single or half brick wall of mix : HSR 11.6\n11.6.2 1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001128 | 119.1 | sqm |
|---|
| 17 | 17 | Providing & laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. HSR 11.57 | BI01010001010000000000000515BI0100001129 | 354.74 | sqm |
|---|
| 18 | 18 | Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 | BI01010001010000000000000515BI0100001130 | 271.87 | sqm |
|---|
| 19 | 19 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : HSR 11.67\n11.67.1 Water thinnable cement primer | BI01010001010000000000000515BI0100001131 | 871.58 | sqm |
|---|
| 20 | 20 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. HSR 11.75\n11.75.2 Two coats | BI01010001010000000000000515BI0100001132 | 396.11 | sqm |
|---|
| 21 | 21 | Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 | BI01010001010000000000000515BI0100001133 | 396.11 | sqm |
|---|
| 22 | 22 | Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 | BI01010001010000000000000515BI0100001134 | 112.82 | sqm |
|---|
| 23 | 23 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 | BI01010001010000000000000515BI0100001135 | 112.82 | sqm |
|---|
| 24 | 24 | Finishing walls with Acrylic Smooth exterior paint of required shade : HSR 11.95\n11.95.1 New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001136 | 475.47 | sqm |
|---|
| 25 | 25 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. HSR 30.19 +\nFlush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska :HSR 30.20\n30.20.1 With F.P.S. brick tiles | BI01010001010000000000000515BI0100001137 | 191.67 | sqm |
|---|
| 26 | 26 | Providing and fixing best quality P.O.P. false ceiling (12mm to 15mm thick) including wire mesh 24 gauge G.I. Angles 50 x 12 | channels 50mm | 60mm x 12mm | Tees flats 20mm etc including cutting holes for Electrical light points and plus minus profile design complete in all resects as per instructions of Engineer-in-charge at site. N.S | BI01010001010000000000000515BI0100001138 | 76.66 | S qm |
|---|
| 27 | 27 | Providing and fixing best quality WPC chowkhats size 5\" x 2½\" with necessary hold fast / fastener etc. complete in all respects . Complete as directed by Engineering -in-charge. N.S. | BI01010001010000000000000515BI0100001139 | 178.5 | Mtr. |
|---|
| 28 | 28 | Providing & fixing best quality wooden ceiling including wooden frame all around The ceiling and top surface and side is covered with 12mm ply board and top surface covered with veneery ply wood with milian polished completes in all respects as per drawing and design. N.S. | BI01010001010000000000000515BI0100001140 | 6.05 | S qm |
|---|
| 29 | 29 | Providing and fixing best quality WPC door (Fire resident) 32mm thick with required steel fitting for door complete as per design fixed in position. N.S. | BI01010001010000000000000515BI0100001141 | 26.73 | S qm |
|---|
| 30 | 30 | Providing & fixing PVC glazed window shutter 32mm thick including steel fitting and 5mm thick plain glass. Complete in all respects as per drawign and design. N.S. | BI01010001010000000000000515BI0100001142 | 4.34 | S qm |
|---|
| 31 | 31 | Providing and fixing tuffen glass 10mm thick including all beading, corrner gola and fitting at site as per requirement make saint gobian Tata. N.S. | BI01010001010000000000000515BI0100001143 | 13.84 | S qm |
|---|
| 32 | 32 | Providing and fixing tuffen glass 12mm thick openable / fixed including all accessories/fittings of Ozone, TaTa etc. at site as per requirement.N.S. | BI01010001010000000000000515BI0100001144 | 12.15 | S qm |
|---|
| 33 | 33 | Providing and fixing 60 cm deep cupboard consisting of 19mm Board (PVC) Heavy density front opening duly covered with 1mm thick sunmica. In side box with 18mm thick WPC, 18mm thick WPC vertical and Horizental shelves and drawer complete in all respect with necessary fittings, locks etc. (outer front area of cupboard will be measured for payment.) N.S. | BI01010001010000000000000515BI0100001145 | 37.15 | S qm |
|---|
| 34 | 34 | Providing & fixing blinds Zebra make in windows. Complete in all respects and design approved by Engineer-in-charge. (N.S.) | BI01010001010000000000000515BI0100001146 | 240.9 | S qft. |
|---|
| 35 | 35 | Public Health Items 35 to 56\nSupply & fixing of E.W.C. wall Hang (39951) Nest Vitra make). Master Bed Room, Guest Room 2 No. Jaquar (N.S.) | BI01010001010000000000000515BI0100001147 | 3 | Each |
|---|
| 36 | 36 | Supply & fixing of concealed Tank flush complete Jaquar (N.S.) | BI01010001010000000000000515BI0100001148 | 3 | Each |
|---|
| 37 | 37 | Supply & fixing of Thermostate Divertor Jaquar 683 (N.S.) | BI01010001010000000000000515BI0100001149 | 3 | Each |
|---|
| 38 | 38 | Supply & fixing of plain spout Jaquar 37429 + 35683 KPM (N.S.) | BI01010001010000000000000515BI0100001150 | 7 | Each |
|---|
| 39 | 39 | Supply & fixing of overhead shower 16\" jaquar 70051 (N.S.) | BI01010001010000000000000515BI0100001151 | 3 | Each |
|---|
| 40 | 40 | Supply & fixing of wall mounted basin mixer with necessary counter and shutter/drawer complete 233 N Jaquar (N.S.) | BI01010001010000000000000515BI0100001152 | 4 | Each |
|---|
| 41 | 41 | Supply & fixing of Angle valve Jaquar Kitchen 35053 PM (N.S.) | BI01010001010000000000000515BI0100001153 | 23 | Each |
|---|
| 42 | 42 | Supply & fixing of Wash Basin 25909 (N.S.) | BI01010001010000000000000515BI0100001154 | 4 | Each |
|---|
| 43 | 43 | Supply & fixing of Towel Rack Conti Jaquar 11845 (N.S.) | BI01010001010000000000000515BI0100001155 | 4 | Each |
|---|
| 44 | 44 | Supply & fixing of Towel Ring Jaquar 1121BN (N.S.) | BI01010001010000000000000515BI0100001156 | 5 | Each |
|---|
| 45 | 45 | Supply & fixing of tumbler Holder Jaquar 1141 N (N.S.) | BI01010001010000000000000515BI0100001157 | 4 | Each |
|---|
| 46 | 46 | Supply & fixing of liquid soap dispenser Jaquar 1135 N (N.S.) | BI01010001010000000000000515BI0100001158 | 4 | Each |
|---|
| 47 | 47 | Supply & fixing of health faucet 573 (N.S.) | BI01010001010000000000000515BI0100001159 | 4 | Each |
|---|
| 48 | 48 | Supply & fixing of glass corner single shelves 1173 (N.S.) | BI01010001010000000000000515BI0100001160 | 5 | Each |
|---|
| 49 | 49 | Supply & fixing of CP Wall mixer Jaquar (N.S.) | BI01010001010000000000000515BI0100001161 | 3 | Each |
|---|
| 50 | 50 | Supply & fixing of .S.S. Sink (Nirali) 24\" x 18\" x 8\" (N.S.) | BI01010001010000000000000515BI0100001162 | 1 | Each |
|---|
| 51 | 51 | Supply & fixing of C.P. Bib Cock short Jaquar (N.S.) | BI01010001010000000000000515BI0100001163 | 2 | Each |
|---|
| 52 | 52 | Supply & fixing & fixing of looking glass of Sant Gobbin Modi 5mm with spacer, nut bolt with frame complete (N.S.) | BI01010001010000000000000515BI0100001164 | 2.3 | S qm |
|---|
| 53 | 53 | Supply & fixing of PVC & CPVC pipe 3\", 4\", 2\" 1\", 3/4\" and 1/2\" for EWC or any fitting required for completing the toilet if required at site as per actual requirement. (N.S.) | BI01010001010000000000000515BI0100001165 | 6 | Set |
|---|
| 54 | 54 | Supply & fixing U.W.C. with cistern and all say used in fixing and also including necessary CPVC & uPVC fitting. Complete fixed position. (N.S.) | BI01010001010000000000000515BI0100001166 | 1 | Each |
|---|
| 55 | 55 | Supply & fixing of 25 litre capacity Electrical geyser. Complete in all respect. (N.S.) Jaquar Make | BI01010001010000000000000515BI0100001167 | 3 | Each |
|---|
| 56 | 56 | Supply & fixing of paper holder. Complete in all respect. (N.S.) | BI01010001010000000000000515BI0100001168 | 4 | Each |
|---|
| 57 | 57 | Electrical Work Items 57 to 130\nWiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. HSR 23.3.6\n23.3.6.1 1 run of Size 1.50 Sqmm(1/1.40mm) | BI01010001010000000000000515BI0100001169 | 70 | metre |
|---|
| 58 | 58 | 23.3.6.2 1 run of Size 2.50 Sqmm(1.1.80mm) | BI01010001010000000000000515BI0100001170 | 50 | metre |
|---|
| 59 | 59 | 23.3.6.6 2 run of Size 1.50 Sqmm(1/1.40mm) | BI01010001010000000000000515BI0100001171 | 50 | metre |
|---|
| 60 | 60 | 23.3.6.7 2 run of Size 2.50 Sqmm(1.1.80mm) | BI01010001010000000000000515BI0100001172 | 50 | metre |
|---|
| 61 | 61 | 23.3.6.8 2 run of Size 4 Sqmm(1/2.24mm) | BI01010001010000000000000515BI0100001173 | 50 | metre |
|---|
| 62 | 62 | Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. HSR 23.4.1\n23.4.1.3 Group C | BI01010001010000000000000515BI0100001174 | 90 | each |
|---|
| 63 | 63 | Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. HSR 23.4.2\n23.4.2.3 Group C | BI01010001010000000000000515BI0100001175 | 10 | each |
|---|
| 64 | 64 | Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch HSR 23.4.3\n23.4.3.3 Group C | BI01010001010000000000000515BI0100001176 | 5 | each |
|---|
| 65 | 65 | Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required HSR 23.4.4\n23.4.4.3 Group C | BI01010001010000000000000515BI0100001177 | 40 | each |
|---|
| 66 | 66 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required HSR 23.4.5\n23.4.5.3 Group C | BI01010001010000000000000515BI0100001178 | 30 | each |
|---|
| 67 | 67 | Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. HSR 23.5.6\n23.5.6.1 1 run of size 1.50 sqmm (1/1.40mm) | BI01010001010000000000000515BI0100001179 | 30 | metre |
|---|
| 68 | 68 | 23.5.6.2 1 run of size 2.50sqmm (1.1.80mm) | BI01010001010000000000000515BI0100001180 | 40 | metre |
|---|
| 69 | 69 | 23.5.6.3 1 run of size 4 sqmm (1/2.24mm) | BI01010001010000000000000515BI0100001181 | 50 | metre |
|---|
| 70 | 70 | 23.5.6.4 1 run of size 6 sqmm (1/2.80mm) | BI01010001010000000000000515BI0100001182 | 20 | metre |
|---|
| 71 | 71 | Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. HSR 23.7.6\n23.7.6.1 PVC pipe of 20 mm dia. | BI01010001010000000000000515BI0100001183 | 30 | metre |
|---|
| 72 | 72 | 23.7.6.2 PVC pipe of 25 mm dia. | BI01010001010000000000000515BI0100001184 | 70 | metre |
|---|
| 73 | 73 | 23.7.6.3 PVC pipe of 32 mm dia. | BI01010001010000000000000515BI0100001185 | 20 | metre |
|---|
| 74 | 74 | Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. HSR 23.8.2\n23.8.2.2 3mm thick | BI01010001010000000000000515BI0100001186 | 1000 | \nsqcm |
|---|
| 75 | 75 | Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite \t0 sheet as below HSR 23.8.3\n23.8.3.1 75 mm x 75 mm x 60 mm deep M.S. box | BI01010001010000000000000515BI0100001187 | 4 | each |
|---|
| 76 | 76 | 23.8.3.2 100 mm x 100 mm x 60 mm deep M.S. box | BI01010001010000000000000515BI0100001188 | 3 | each |
|---|
| 77 | 77 | 23.8.3.3 180 mm X 100 mm X 60 mm deep M.S. Box | BI01010001010000000000000515BI0100001189 | 2 | each |
|---|
| 78 | 78 | 23.8.3.4 200 mm X 150 mm X 60 mm deep metal box | BI01010001010000000000000515BI0100001190 | 1 | each |
|---|
| 79 | 79 | 23.8.3.5 200 mm X 150 mm X 60 mm deep metal box | BI01010001010000000000000515BI0100001191 | 7 | each |
|---|
| 80 | 80 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. HSR 23.8.10\n23.8.10.1 1 & 2 Modules including combined plate for Telephone and data | BI01010001010000000000000515BI0100001192 | 6 | each |
|---|
| 81 | 81 | 23.8.10.2 3 modules | BI01010001010000000000000515BI0100001193 | 2 | each |
|---|
| 82 | 82 | 23.8.10.4 6 modules | BI01010001010000000000000515BI0100001194 | 1 | each |
|---|
| 83 | 83 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. HSR 23.8.11\n23.8.11.1 5 amp 1 way switch | BI01010001010000000000000515BI0100001195 | 125 | each |
|---|
| 84 | 84 | 23.8.11.2 5 amp 2 way switch | BI01010001010000000000000515BI0100001196 | 10 | each |
|---|
| 85 | 85 | 23.8.11.3 15 amp 1 way switch | BI01010001010000000000000515BI0100001197 | 30 | each |
|---|
| 86 | 86 | 23.8.11.4 5 amp Socket | BI01010001010000000000000515BI0100001198 | 40 | each |
|---|
| 87 | 87 | 23.8.11.5 15 amp 6 pin Socket | BI01010001010000000000000515BI0100001199 | 30 | each |
|---|
| 88 | 88 | 23.8.11.6 Bell Push | BI01010001010000000000000515BI0100001200 | 2 | each |
|---|
| 89 | 89 | 23.8.11.7 step type Fan Regulator 2 modules 300 watt | BI01010001010000000000000515BI0100001201 | 15 | each |
|---|
| 90 | 90 | 23.8.11.8 Telephone Socket outlet modular type | BI01010001010000000000000515BI0100001202 | 6 | each |
|---|
| 91 | 91 | 23.8.11.9 TV Socket outlet modular type | BI01010001010000000000000515BI0100001203 | 6 | each |
|---|
| 92 | 92 | 23.8.11.10 Blanking plate | BI01010001010000000000000515BI0100001204 | 10 | each |
|---|
| 93 | 93 | 23.8.11.11 RJ 45 computer data socket outlet for CAT 6 or CAT 6e cable modular type | BI01010001010000000000000515BI0100001205 | 6 | each |
|---|
| 94 | 94 | 23.8.11.13 32A D.P. Main Switch With Key Ring Tag 2 Module ( For Guest room or similar use only ) | BI01010001010000000000000515BI0100001206 | 6 | each |
|---|
| 95 | 95 | Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. HSR 23.22.1\n23.22.1.3 Triple pole MCCB 16 to 100 amp 25KA | BI01010001010000000000000515BI0100001207 | 1 | each |
|---|
| 96 | 96 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- HSR 23.22.5 \n23.22.5.1 6 amp. to 32 amp Single Pole | BI01010001010000000000000515BI0100001208 | 22 | each |
|---|
| 97 | 97 | Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. HSR 23.23.8\n23.23.8.1 2 pair telephone wire | BI01010001010000000000000515BI0100001209 | 100 | metre |
|---|
| 98 | 98 | 23.23.8.2 4 pair telephone wire | BI01010001010000000000000515BI0100001210 | 50 | metre |
|---|
| 99 | 99 | Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required HSR 23.23.9 | BI01010001010000000000000515BI0100001211 | 100 | metre |
|---|
| 100 | 100 | Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required HSR 23.23.10 | BI01010001010000000000000515BI0100001212 | 100 | metre |
|---|
| 101 | 101 | Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc. HSR 23.25.1\n23.25.1.1 Light, fan or call bell Point including circuit/sub main wiring | BI01010001010000000000000515BI0100001213 | 90 | each |
|---|
| 102 | 102 | 23.25.1.2 Wall socket point including circuit/submain wiring | BI01010001010000000000000515BI0100001214 | 50 | each |
|---|
| 103 | 103 | Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR 24.1.3 | BI01010001010000000000000515BI0100001215 | 1 | each |
|---|
| 104 | 104 | Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR 24.1.5 | BI01010001010000000000000515BI0100001216 | 1 | each |
|---|
| 105 | 105 | Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.HSR 24.1.7 | BI01010001010000000000000515BI0100001217 | 5 | metre |
|---|
| 106 | 106 | Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required HSR 24.1.12 | BI01010001010000000000000515BI0100001218 | 20 | metre |
|---|
| 107 | 107 | Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. HSR 24.2.6\n24.2.6.1 1.5 Sqmm | BI01010001010000000000000515BI0100001219 | 25 | each |
|---|
| 108 | 108 | 24.2.6.2 2.5 Sqmm | BI01010001010000000000000515BI0100001220 | 5 | each |
|---|
| 109 | 109 | 24.2.6.3 4Sqmm | BI01010001010000000000000515BI0100001221 | 10 | each |
|---|
| 110 | 110 | 24.2.6.4 6 Sqmm | BI01010001010000000000000515BI0100001222 | 10 | each |
|---|
| 111 | 111 | S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. HSR 24.5.2\n25.5.2. DWC/HDPE pipe 50/40 mm outer dia/ inner dia | BI01010001010000000000000515BI0100001223 | 100 | metre |
|---|
| 112 | 112 | S/E testing and commissioning of cubical type, dust and verman proof wall mounting LT panel made out of 20G M.S. sheet painted with strong synthetic light gray enamal paint suitable for operation on 3 phase 4 wire 50 cycles 400/440 volts A.C. supply including the cost of the following items \nINCOMING:- space for accomdating 1 no. MCCB of 200amp. Three pole complete with siutable size of cable chamber to receive incoming cable in sheet steel cubical.\nNeutral Link\nA set of LED lamps (3 nos.) phase indicating light\nOUTGOING: L.T. oannel should be having sufficeint spce for accomodating the following switches/ M.S.B.'s including the cost of the MCB and metering system as required.\nThe panel should be completed with all inter wiring with PVC copper wire and testing etc. complete the job in all respect upto the entire satisfaction of Engineer In-charge of the work\n | BI01010001010000000000000515BI0100001224 | 1 | each |
|---|
| 113 | 113 | Supply, installation, testing and commissioning if parking LED light complete in all respect with all fixing accessaries as required. N.S.2 | BI01010001010000000000000515BI0100001225 | 5 | Each |
|---|
| 114 | 114 | S/E/I/T/C of following sizes of energgy saving type ceiling fan complete with double ball bearing. motor, blades, downrod, canopy, capacitor, etc. suitable for operation on 230 volts 50 Hz A.C. supply complete as required. Make, Havells leganza 4 blade required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work N.S. 3\n(i) size 600mm | BI01010001010000000000000515BI0100001226 | 4 | Each |
|---|
| 115 | 115 | Size 900mm | BI01010001010000000000000515BI0100001227 | 3 | Each |
|---|
| 116 | 116 | Size 1200mm | BI01010001010000000000000515BI0100001228 | 7 | Each |
|---|
| 117 | 117 | S/E/I/T/C of following sizes of heavy duty ventilation type exhaust fan suitable for single phase 230 volts, 50 Hz AC supply complete with motor, capacitor, louvers / shutters etc. complete as required. Make- Havells N.S. 4\n200 mm dia | BI01010001010000000000000515BI0100001229 | 6 | Each |
|---|
| 118 | 118 | Supply,installation, Testing commissioning of 1x9 watt LED blub with all accessories as per required N.S.5 | BI01010001010000000000000515BI0100001230 | 3 | Each |
|---|
| 119 | 119 | Suppy,installation testing and commissioning of 0.5HP high speed motor automatic sytem operating complete with all connection and all fixing accessories as per required N.S. 6 | BI01010001010000000000000515BI0100001231 | 1 | Each |
|---|
| 120 | 120 | Supply, installation testing, commissioning of fencing light with 1x9 watt LED blub with all complete connections as per required N.S. 7 | BI01010001010000000000000515BI0100001232 | 4 | Each |
|---|
| 121 | 121 | Supply,installation, Testing commissioning of jhumar type fencing light with 1x9 watt LED blub with all complete connections as per required N.S. 8 | BI01010001010000000000000515BI0100001233 | 1 | Each |
|---|
| 122 | 122 | Installation, Testing commissioning of Split type A.C.1.5 Ton 1 phase 3 Star with suitable stand and all complete connections as per required to complete the job in all respect upto the enter satisfction of Engineer In-charge of the work. Make:- Blue Star/Carrier/Dekon ( N.S. 9) | BI01010001010000000000000515BI0100001234 | 4 | Each |
|---|
| 123 | 123 | S/E/I/T/C of out door light fixture including the cost of 12 watt LED blub and outer iron frame complete with all fixing acceseries as reqiored upto the entire satisfaction of the Engineer In-charge of the work. Make - Bajaj/Philips/Havells (NS 10) | BI01010001010000000000000515BI0100001235 | 6 | each |
|---|
| 124 | 124 | Supply and erection of following light fixture complete with all fixing accesaries as required \nS/E/I/T/C 1x15 W LED fall ceiling panel light 6000K\nMake - Philips/Havells (NS 11) | BI01010001010000000000000515BI0100001236 | 97 | each |
|---|
| 125 | 125 | S/E/I/T/C of following LED COP light fixture complete with all fixing accesaries as required 18 watt 6000K Make - Havells/Philips (NS-12) | BI01010001010000000000000515BI0100001237 | 100 | metre |
|---|
| 126 | 126 | Supply, erection , installation, testing and commissioning of following BUSH and SPIKE LED LIGHT complet with all fixing accessaries as required.\nS/E/I/T/C 1 x 9 Watt BUSH and SPIKE LED light Make -Havells/Philips (NS 13) | BI01010001010000000000000515BI0100001238 | 27 | each |
|---|
| 127 | 127 | Supply, installation, testing and commissioning of split type A.C. 2 ton 1 phase 3 star with suitable stand and all complete connections as per required to complete the job in all respect upto the enter satisfction of Engineer In-charge of the work Make-Blue Star, Carrier , Voltas (NS 14) | BI01010001010000000000000515BI0100001239 | 1 | each |
|---|
| 128 | 128 | Supply and erection of underground cable loose in existing pipe or trenches complete with necessary connections\n10 sqmm 2 core cable Armoured (NS-15) | BI01010001010000000000000515BI0100001240 | 120 | metre |
|---|
| 129 | 129 | 35sqmm 4 core cable Armoured (NS-16) | BI01010001010000000000000515BI0100001241 | 100 | metre |
|---|
| 130 | 130 | Supply, Installation, Testing and commissioning of telephone junction box (DP box) with 10 pair module all complete connections as per required to complete the job in all respect upto the enter satisfction of Engineer In-charge of the work (NS-17) | BI01010001010000000000000515BI0100001242 | 1 | each |
|---|