}

Out Sourcing Of Services At Water Supply Distribution System At Pump House No 27 31 34 36 29 32 12 28 Fafa Under Ge East Bareilly, BAREILLY-Uttar Pradesh

Military Engineer Services has published Out Sourcing Of Services At Water Supply Distribution System At Pump House No 27 31 34 36 29 32 12 28 Fafa Under Ge East Bareilly. Submission Date for this Tender is 17-07-2021. Couplings Tenders in BAREILLY Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28126367
Corrigendum : Out Sourcing Of Services At Water Supply Distribution System At Pump House No 27 31 34 36 29 32 12 28 Fafa Under Ge East Bareilly
Tender
Indian
Uttar Pradesh
Bareilly
17-07-2021

Tender Details

Out Sourcing Of Services At Water Supply Distribution System At Pump House No 27 31 34 36 29 32 12 28 Fafa Under Ge East Bareilly , Outsourcing Of Services Of Following Pump Houses By Providing Skilled Operator For Opertion , Round The Clock In Three Shifts Of 8 Hrs Each At Pump Houses For Operation Of Submersible Pumping Set And Diesel Generating Set ( Including Operation Of Valves Control Pannel , Starters Etc ) Dosing Plants And Bleaching Dozer , Filing Of Water In Oh Tank /Reservoirs Etc Of Following Capacities And Pump Houses Mentioned In Suceeding Paras Herein Including Maintaining Chlorination 2 Ppm At Source Mentioned Herein After :-Ph No 37 Fafa Map Adf Gate ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 25000 Gallon- 02 No ( V ) Lt Panel -01 Nos , Ph No 37 Fafa Map Adf Gate ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 25000 Gallon- 02 No ( V ) Lt Panel -01 Nos , Ph No 12 ( Fort Road ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 50000 Gallon- 02 No ( V ) Lt Panel -01 Nos , Ph No 28 ( Near Hq Ub Area ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 100000 Gallon- 01 No ( V ) Lt Panel -01 Nos , Ph No 32 ( Station Road ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 25000 Gallon- 01 No ( V ) Lt Panel -01 Nos , Ph No 34 ( Jrc ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 50000 Gallon- 02 No ( V ) Lt Panel -01 Nos , Ph No 36 ( Jrc ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 50000 Gallon- 02 No ( V ) Lt Panel -01 Nos , Ph No 29 ( Badaun Road ) ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Oh Tank 100000 Gallon- 02 & 50000 Gallon 01 No ( V ) Lt Panel -01 Nos , Ph No 27/31 Pb Marg ( I ) Submersible Pumping Set Of 30 To 50 Hp Discharge 2700 Lpm To 5200 Lpm -01 No ( Ii ) Dg Set 63/125 Kva -01 No ( Iii ) Chlorine Dosing Plant . - 01 Set ( Iv ) Lt Panel -01 Nos , Notes: - For All ItemsContractor Shall Keep The Following Aspects In Mind While Quoting Unit Rates And Rates Quoted Shall Be Deemed To Be Including The Following: - ( A ) Operator Should Be Holding Iti Certificate With Experience In Relavent Fields For Operating Pumps , Dg Sets , Chloronome Plants And Bleaching Dozers And Pipe Fitter With Experience In Maintaining All External Water Supply Pipe Lines And Distribution Lines ( B ) Operator Should Not Be Deriving Pension From Any Govt/Semi Govt Or Public Sector Undertaking . Any Disputes Will Be At Discretion Of Ge And Decision Shall Be Binding On Contractor . ( C ) Operator Shall Posses , Police Verification Certificate . ( D ) Contractor Shall Be Responsible For Safety , Security And Upkeep Of Installation As Per Mes Standards For Installation . ( E ) Contractor Shall Provide Operator At The Rate Of Three Shifts A Day I . E . ( I ) 1St Shift - 0600Hrs To 1400 Hrs ( Ii ) 2Nd Shift -1400 Hrs To 2200 Hrs ( Iii ) 3Rd Shift - 2200 Hrs To 0600 Hrs ( F ) Contractor Shall Put Up Every Month Intearaction With Opertor Register To Engr-In-Charge And Ge ( G ) Duty Roster For One Month Will Be Prepared In Advance And Displayed At Prominent Places In Installations And Water Supply Yard To Include Names , Shifts And Residential Address , Contact Number Etc . Operator Reserve For Leave/Sickness Etc Shall Also Be Provided And Dispalyed On Duty Roster / Register . ( H ) Contractor Shall Stop Leakage From Glands Or Coupling Joints Etc In The Pump House Premises , . . ( J ) Contractor Shall Ensure Through Operator For Day To Day Upkeep And Check Of Pumping Set As Per Manufacturers Instructions And Carry Out Minor Repairs Of Following Nature By Own Arrangement To The Satisfaction And Direction Of Engr In Charge :- ( I ) Glands ( Ii ) Greasing ( Iii ) Dusting Of Plant & Machinery . ( Iv ) Weeding/ Rooting Out Grass Roots , Vegetation Etc . ( V ) Contractor Shall Carry Out Pre Monsoon Maintenance Of Pumps To The Satisfication Of Engr-In-Charge . ( Vi ) Dhpp ( N ) Will Be Supplied By The Department ( Vii ) Log Sheet Of Dg Set As Well As Pump Should Be Provided By The Contractor & To Be Employed By The Contractor Maintained By The Operator Employed By Contractor . ( K ) Contractor Shall Ensure Through Operator Running Of Chloronome Plant Or Bleaching Dozer Including Maintaining Chlorination At 2 Ppm By Operation Of Chlorination Valve . Chlorine Testing Kit Shall Be Provided By The Contractor & Rates Are Deemed To Be Included In The Quoted Rate . ( L ) Chlorinated Water Shall Be Supplied To Overhead Tank Through Operation Of Valve Provided At Site . ( M ) Water Supply & Pumping Distribution Timings Are As Under :- ( I ) Water Supply To Oh Tank And Operation Of Pump 0300 Hrs To 0900 Hrs 1100 Hrs To 1500 Hrs 1500 Hrs To 2200 Hrs ( Ii ) Distribution Timing 0600 Hrs To 0800 Hrs 1200 Hrs To 1300 Hrs 1800 Hrs To 2000 Hrs ( Iii ) Any Change Shall Be Notified By Engr-In-Charge And Adhered To By Operator ( Q ) Log Sheet Provided At Pump House Shall Be Maintained And Handing/Taking Between Continuous Operator Shall Be Done Correctly As Per Norm Of Mes . ( R ) Emergencies Shall Be Notified To Engr In Charge/Je/Mcm . Routine Operation Should Be Under Supervison Of Mcm Designated By Engr-In-Charge . ( S ) Contractor Shall Cutting The Roots / Grass Sorrounding Pump House Area Every Month And Is Check Off To Je E/M/ Engr-In Charge ( T ) If Any Opertor Found Absent In Duty Rs 1500/- Will Be Deducting Per Shift

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-07-2021 REVISED DATE Date 17-07-2021
2 16-06-2021 REVISED BOQ BOQ 28-06-2021
3 28-06-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail