Addition/ Alteration To Bldg No . P-183 At Ins Karna And Provision Of Compound Wall Around Certain Govt Married Accommodations ( Koq 16 , 28 , 29 , 30 , 31 , 32 And 33 ) In Phase-I Area Under Lbw At Naval Station Bheemunipatnam

Tender Notice

28057960
Corrigendum : Addition/ Alteration To Bldg No . P-183 At Ins Karna And Provision Of Compound Wall Around Certain Govt Married Accommodations ( Koq 16 , 28 , 29 , 30 , 31 , 32 And 33 ) In Phase-I Area Under Lbw At Naval Station Bheemunipatnam
Indian
Andhra Pradesh
22-06-2021
29-06-2021
01-07-2021

Tender Details

Addition/ Alteration To Bldg No . P-183 At Ins Karna And Provision Of Compound Wall Around Certain Govt Married Accommodations ( Koq 16 , 28 , 29 , 30 , 31 , 32 And 33 ) In Phase-I Area Under Lbw At Naval Station Bheemunipatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 85200.00 /-
Tender Value
INR 42.60 Lakhs /-

BOQ Items

Name of Work : ADDITION/ ALTERATION TO BLDG NO. P-183 AT INS KARNA AND PROVISION OF COMPOUND WALL AROUND CERTAIN GOVT MARRIED ACCOMMODATIONS ( KOQ 16, 28, 29, 30, 31, 32 & 33) IN PHASE-I AREA UNDER LBW AT NAVAL STATION BHEEMUNIPATNAM
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for single stanchions, built up of one MS tube conforming to IS 1161-1979 grade Yst 240 with flange plates, caps, bases, splices angle brackets, cleats and other connections complete all as specified and as directed. 264.58 Kg
2 2 M&L mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 W (Gde-E-250) quality A complete all as specified and as directed. 268.3 Kg
3 3 S & F steel work in tubular trusses, purlins including special shaped washer etc. including necessary arrangement to make arch shape complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and as directed. 1594.33 Kg
4 4 M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified. 3.82 Cum
5 5 M&L 6mm thick asbestos cement (corrugated, semi corrugated etc.) sheets in roof, walls etc fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed. 77 Sqm
6 6 S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (i.e. including coating) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. 46 Sq.m.
7 7 S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wires etc; flat iron fillets (for securing wire mesh) complete all as specified and as directed. 77.53 Kg
8 8 S & F 16 to 20mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nut exc 5 cm but n.exc 10cm long complete all as directed 54.78 Kg
9 9 S & F 16 to 20mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts n.exc 30cm long complete all as directed 41.04 Kg
10 10 M&L preparing new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified. 153.97 Sqm
11 11 Taking down cement plaster on brick or stone work wall including racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. 52 Sqm
12 12 M&L for rendering 10 mm thick with CM 1:6 on internal plaster of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 52 Sq.m.
13 13 M&L applying two coats of exterior emulsion paints over a coat of primer including preparation of new external wall surfaces complete all as specified and as directed. 852 Sqm
14 14 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge. 18.38 Cu.m.
15 15 M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in bed concrete, foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. 27.77 Cu.m.
16 16 M&L for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6 complete all as specified and directed by the Engineer-in-Charge. 20.22 Cu.m.
17 17 Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick complete all as specified and as directed. 312.66 Cum
18 18 Removing excavated soil from site to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre from the starting point complete all as specified. 92.96 Cum
19 19 M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 in double layer using WPC in outer layer of 5 mm thick complete all as specified and as directed by the Engineer-in-Charge.\nNote: WPC will be measured and paid separately 15 Sq.m.
20 20 Supply only Integral Water Proofing Compound (ISI marked) of approved make. 1.5 Kg
21 21 M&L for broken stone or boulders in hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 13 Cu.m.
22 22 M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge. 29 Sq.m.
23 23 M&L 50 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in sub base complete all as specified and as directed. 20 Sqm
24 24 S&F glazed ceramic tiles in vertical surface (skirting) 300 x 450 x 7mm thick or 250 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match joint free over rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge. 30 Sq.m.
25 25 S&F PVC (SWR) pipes 75 mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge. 15 Rm
26 26 Rough excavation not exceeding 1.5m deep and getting out in hard/ dense soil complete all as specified and as directed. 90 Cum
27 27 Removing excavated materials (soil) exc 1.5 Km but n. exc 5.0 km and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed 90 Cum
28 28 M&L for forming embankments including raising (or lowering) earth, spreading in layers n.exc 30cm thick, watering, ramming/rolling and finishing to required size, shape etc. n.exc 1.5m high from base complete all as specified and as directed. 90 Cum
29 29 Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as directed. 75 Sqm
30 30 M&L 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed. 75 Sqm
31 31 M & L designer chequered cement concrete tiles rubber moulded 30 cm x 30cm x 25 cm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed or bedding layer of CM (1:4) complete all as specified and as directed 75 Sqm
32 32 Providing precast cement concrete in 1:2:4 type B1 in kerb stone, window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and as directed. 0.33 Cum
33 33 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed by the Engineer-in-Charge. 260 Cu.m.
34 34 M&L for Reinforced Cement Concrete,1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in foundations, including rafts, footings, plinth beams etc and the like complete all as specified and directed. 50 Cu.m.
35 35 M&L for Reinforced Cement Concrete, 1:1.5:3, type A1 (Using 20mm graded granite stone aggregate) in columns, pillars, piers, posts and struts etc and the like complete all as specified and directed. 30 Cu.m.
36 36 M&L for Reinforced Cement Concrete 1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in beams, cantilevers, lintels over 1.5 m span etc and the like complete all as specified and directed. 14.72 Cu.m.
37 37 Use and waste of form work to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces complete all as specified and directed. 382.35 Sq.m.
38 38 Use and waste of form work to sides of columns, pillars, posts, struts, piers and stanchions etc for fair finished surfaces complete all as specified and directed. 492.98 Sq.m.
39 39 Use and waste of form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc, for fair finished surfaces complete all as specified and directed. 128 Sq.m.
40 40 M & L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 4000 Kg
41 41 M & L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 1000 Kg
42 42 M & L Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick wall built in CM(1:4) complete all as specified and as directed 175 Sq.m.
43 43 M&L for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in bed plates, and the like including necessary formwork weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed 17.5 Cum
44 44 M&L for rendering 10mm thick with CM 1:4 on fair faces of brick work or concrete surfaces, finished even and fair complete all as specified and as directed by the Engineer-in-Charge. 800 Sq.m.
45 45 M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railings, framework of water tanks and similar work conforming to Fe 290 Gde-E-165 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc for ornamental and intricate design complete all as specified and as directed by the Engineer-in-Charge. 500 Kg
46 46 S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed 15 Kg
47 47 M&L for providing precast cement concrete type B-0 (using 12.5 mm graded aggregate) as in louvers and jallies, 40mm thick (measured solid), set in CM 1:4 including all mouldings complete all as specified and as directed 185 Sqm
48 48 S&F RGB IP 68 colour changing LED light (18 watt) including clamp and necessary nut and bolts complete all as specified and as directed.\n(Make : Edision lighting Pvt Ltd/ Sunny light (New Delhi) or equivalent as approved by GE) 8 Each
49 49 S&F power converter box with controller box of same OEM as LED complete all as specified and as directed.\n(Make : Edision lighting Pvt Ltd/ Sunny light (New Delhi) or equivalent as approved by GE) 2 Each Job
50 50 Supply and fixing outdoor integral post top lantern luminaries 40 w LED, IP 65 protection , incl three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed.\nMake : CG CAT NO. LPTO-40-CDL or equivalent as approved by GE 2 Each
51 51 Supply and fixing outdoor integral LED Bollard luminaire 9 watt decorative mushroom shaped with IP 65 protection incl PCC 1:2:4 TYPE B2 foundation Of garden light ,copper conductor flexible wire from busbar to connector all as specified and as directed.\nMake : Bajaj cat no. BLBMC 9W WW LED or equivalent as approved by GE 30 Each
52 52 Supply and fixing outdoor integral florence LED post top luminaries 45 watt with circular design with polycarbonate opal diffuser and IP 65 protection incl PCC 1:2:4 TYPE B2 foundation Of garden light ,copper conductor flexible wire from busbar to connector all as specified and as directed.\nMake : Bajaj cat no. BGCP 45W LED WW or equivalent as approved by GE 2 Each
53 53 Supply, fixing and cable junction boxes of size 155mm x 210mm x 92mm IP 66 for cable entry, comprising of SPN aluminium bus bar of capacity 16 Amp 230 Volt fixed , making holes on strips for connecting cables and fixed to garden light pole with and including MS clamp of size 25mmx5mm incl nut ,bolt, washer and including prvn of MCB SP 6 A, C curve 10kA breaking capacity -1 no with mounting rail all as specified and as directed. 10 Each
54 54 Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends with taking down of old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed.\nNOTE: 3 runs of 4.0 Sqmm and one run of PVC concealed conduit 25 mm dia will be measured as one unit i.e. RM 25 Rm
55 55 Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trench /poles/on wall complete all as specified and as directed 60 Rm
56 56 Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trench /poles/on wall complete all as specified and as directed 400 Rm
57 57 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge. 102.6 Cu.m.
58 58 Supply and spread clean river sand as cable cushioning for protection of cable to be laid in trenches all as per SSR part I complete all as directed by Engineer-in-Charge. \nNote: Punned thickness will be measured and paid. 31 Cum
59 59 Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 in cable trenches complete all as directed 3305 Each
60 60 M&L for galvanized iron tubing 25mm bore light grade with all fittings for protection of FRLS cable, laid in trenches/wall/floor including necessary clamps, bolt/nut complete all as specified and as directed. \nNote: Earth work excavation will be measured and paid separately. 20 RM
61 61 M&L for boring of holes under road, pavement hard standing by trenchless technology using ultrasound technology & necessary machine including provision of HDPE pipe of 40 mm dia suitable for 0.4 MPa working pressure complete all as specified and as directed. 20 RM
62 62 M&L for cutting steel tubing of existing GI pipe line 40/ 25 mm bore for alternation and addition and insert new tee for branch connection complete all as specified and as directed. 3 Each Job
63 63 M&L for galvanized iron tubing 25mm bore medium grade with all fittings laid in trenches complete all as specified and as directed. 100 RM
64 64 M&L for galvanized iron tubing 20mm bore medium grade with all fittings laid in trenches complete all as specified and as directed. 54 RM
65 65 M&L for galvanized iron tubing 15mm bore medium grade with all fittings laid in trenches complete all as specified and as directed. 40 RM
66 66 S&F 25mm dia chromium plated stop valves, screwed complete all as specified and as directed. 1 Each
67 67 S&F 25mm dia gun metal globe gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. 2 Each
68 68 S&F 700 Litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) two layered ISI marked hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge. 1 Each
69 69 S&F sprinkler quick / early response type as per IS 15105/ TAC guidelines, 79 degree temperature rating pendant type complete all as specified and as directed. 4 Each
70 70 M&L complete for valve pit chamber of internal size 600x600x600 mm with full bricks wall in CM (1:4) over 100mm PCC 1:4:8 type B2 including MS sheet cover of 3mm thick including locking arrangement with two coat of synthetic enamel paint over a coat of red oxide primer as specified. \nNote- Unit rate is deem to be included for plastering o internal surface of chamber and exposed surface of external wall with CM 1:3. 1 Each
71 71 S&F open horizontal type submersible pump of 2 HP capacity with fitting and control panel box with 2 HP DOL starter with single phase preventer on/ off main switch etc complete all as specified and as directed. 1 Each
72 72 S&F 25mm dia CP brass nozzle with adjustable multi directional ball joint 220 mm long with water jet discharge (minimum weight 475 gms for each nozzle assembly) etc complete all as specified and as directed.\n(Make : Reva/ KMC/ Jolly or equivalent as approved by GE)\n 1 Each
73 73 S&F 15mm dia CP brass nozzle 100 mm long with water foam discharge (minimum weight 205 gms for each nozzle assembly) etc complete all as specified and as directed.\n(Make : Reva/ KMC/ Jolly or equivalent as approved by GE) 4 Each
74 74 S&F 25mm dia CP brass nozzle 290 mm long with water bell (umbrella) discharge (minimum weight 1000 gms for each nozzle assembly) etc complete all as specified and as directed.\n(Make : Reva/ KMC/ Jolly or equivalent as approved by GE) 1 Each
75 75 S&F submersible cable PVC insulated sheathed 1100 volts grade multistranded copper conductor flat 3 core 6 sqmm complete all as specified and as directed. 25 Rm
76 76 Supply,installation,commission and testing including providing all necessary electrical connection, LT feeder pillar box of size 0.8 m x0.8 m x 0.6 m, outdoor type 3 phase 4 wire, made of 3.15mm thick MS sheet with MS angle iron frame slanting roof, including painting necessary earth work, foundation with PCC 1:2:4 for 4 Nos legs , inclusive of under mentioned items incl provn of insulated TPN copper bus bar of appropriate size mounted on porcelain insulator and internal connection with PVC insulated stranded single core copper cable/strip of suitable size \n(a) MCCB 4 pole, 415 volts,100 amps, 25 KA = 01 No (As Incomer) \n(b) MCCB 4 pole, 415 volts, 32 amps, 25 KA = 02 Nos (out going) \n(C) LED indicator lamp (set of three-Red,Yellow,Blue) -01 set \n(d) Volt meter-01 , Amp meter with CT selector switch -01 1 Each
77 77 S&F LED flood light 80 watt luminarie efficiency of 125 lm/ watt IP 66 protection, guard along complete all accessories prewired and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall / ceiling including flexible wire from fitting to terminal point complete all as specified and as directed.\n(Make CG Cat No. LCNP-80-CD60HPM600 or equivalent as approved by GE) 4 Each
78 78 Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and including PVC conduit medium grade 20mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed.\nNOTE: 3 runs of 2.5 Sqmm and one run of PVC conduit 20 mm dia will be measured as one unit i.e. RM 77 Rm
79 79 Material and labour for point wiring for one light point controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, etc including testing on completion complete all as specified and as directed. 4 Per point
80 80 All as per Srl Item No. 79 here-in-above but for One socket outlet point 3 pin 5 A on independent board. 4 Per point
81 81 All as per Srl Item No. 79 here-in-above but for one switch socket out let for 16 Amps 3 & 5 pin on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire. 2 Per point
82 82 Supply and fixing switch socket outlet multipurpose 3 pin 5 Amp and one 3 pin 15 amp controlled by and one 15 Amp switch all as specified and as directed 2 Each
83 83 Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed 11 Each
84 84 Supply and fixing switch socket combination 5 pin, 5 amp flush type all as specified and as directed 4 Each
85 85 Supply and fixing ceiling rose surface bakelite 65 x 30 mm three terminals all as specified and as directed. 10 Each
86 86 Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar , all as specified and as directed. 1 Each
87 87 Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position, all as specified and as directed. 6 Each
88 88 Supply and fixing in proper position MCB double pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity, all as specified and as directed. 1 Each
89 89 Supply and fixing indoor luminaries decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. \n [Make : CG Cat Part no.CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE] 10 Each
90 90 S&F exhaust fan 300 mm sweep PVC body, 230 Volts single phase AC with louver shutter/ grill including 3 core copper cable from ceiling rose to exhaust fan & required hold fast, cutting holes on walls of suitable size complete all as specified and as directed.\n(Make : Havells Cat No. Ventil Air-DX white or equivalent as approved by GE) 1 Each
91 91 M&L for earthing complete with 7.5m long CI pipe 80mm dia. with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 7.5m length buried directly and preferably vertically in ground with top flanged ended 7m below ground level welded/ connected with GI strip 32x6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400mm dia. bore in any strata of soil to lower the CI pipe complete all as specified and as directed by the Engineer-in-Charge.\nNote: The rate deemed to be included the earth pit chamber, CI cover and earth lead 32x6mm GI strip from earth pit to DB upto 7 mtrs. length and testing on completion. 2 Each