Military Engineer Services-MES has published Repair Replacement Of Joinery Rolling Shutters Roof Treatment Galvalume Frp Sheets Including Certain Em Works Of Certain Bldgs Of 28 Ad Regt 707 Tsu 955 Ad Regt Wkshp Lt Ad Bty And Depot Bty At Zone B Area At Gms Under Ge I Gos. Submission Date for this Tender is 18-06-2021. Shed Construction Tenders in GOPALPUR ON SEA Odisha. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR / REPLACEMENT OF JOINERY, ROLLING SHUTTERS, ROOF TREATMENT GALVALUME / FRP SHEETS INCLUDING CERTAIN EM WORKS OF CERTAIN BLDGS OF 28 AD REGT , 707 TSU , 955 AD REGT WKSHP , LT AD BTY AND DEPOT BTY AT ZONE 'B' AREA AT GMS UNDER GE I GOS. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete unreinforced n exc 15cm thick above ground level complete all as specified and directed. | 12 | Cum | |
2 | 2 | Taking down existing water proofing membrane and cleaning roof, plastered surface etc preparing the surface to receive plaster by brushing with wire brush and fanning the surface to remove all loose dirt etc and brushing neat cement slurry @ 3.00 Kg/Sqm complete all as specified and directed. | 300 | Sqm | |
3 | 3 | M&L for rendering 15 mm thick surface as in roof with integral water proofing compound 3% by the weight of cement in cement mortar 1:4 complete all as specified & directed. (Integral WPC will be measured and paid separately). | 300 | Sqm | |
4 | 4 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base flooring 40 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed. | 300 | Sqm | |
5 | 5 | M&L for water proofing treatment to roof surface complete all as specified & directed with the followings :- \n(a) Apply bituminous based primer confirming to IS: 3384-1965 @ 0.30 kg/sqm. (b) APP modified bituminous membrane 3mm thick with non woven polyester core of weight not less than 3.2 to 3.5 Kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (c) Applying bituminous based aluminium paint @ 0.20 Kgs/Sqm in two coats over APP membrane | 300 | Sqm | |
6 | 6 | Supply only integral water proofing compound complete all as specified and directed. | 83 | Kg | |
7 | 7 | Taking down rolling shutters of any size complete all as specified & directed. | 5 | Each | |
8 | 8 | S&F of steel rolling shutters as per IS-6248-1979, made of required size MS laths interlocked together through their entire length and jointed together at the ends by end locks mounted on shafts (50 mm dia) heavy duty, thickness of lathe 1.20mm, grade II springs, guide channel 3.15mm thick, bottom plate 3.15mm thick gear oprated shutter with bevel gear box and crank handle, hood cover 1.20mm and 1 coat of red oxide primer including necessary concrete bed blocks with PCC 1:3:6 of size wall width x 150mm x300 mm and finishing with plaster 15mm thick in CM 1:4 finished even and smooth complete all as specified and directed. | 86 | Sqm | |
9 | 9 | S&F ball bearing suitable for rolling shutter compete all as specifed & directed. | 21 | Each | |
10 | 10 | S&F safety lever locks with four levers for rolling shutters complete all as specified and directed. | 20 | Each | |
11 | 11 | S & F MS pipe 50 to 125 mm dia as shaft including two coats of aluminum paint over a coat of red oxide primer complete all as specifed & directed. | 120 | Kg | |
12 | 12 | Supply only following parts of steel rolling shutters Gear Box Set general. | 15 | Each | |
13 | 13 | Guide channel 3" (3.15 mm) | 50 | RM | |
14 | 14 | Bottom plate 5" (2.25mm) | 21.5 | RM | |
15 | 15 | Greasing and servicing only to existing rolling shutters area of shutter n exc 20 Sqm each complete all as specified and directed. | 10 | Each | |
16 | 16 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | 286 | Sqm | |
17 | 17 | Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed. | 200 | Sqm | |
18 | 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | 3 | Qtl | |
19 | 19 | Excavation in any type of soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good disturbed surface complete all as specified and directed. | 20 | Each | |
20 | 20 | S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed. | 1200 | kg | |
21 | 21 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. | 200 | Sqm | |
22 | 22 | Demolition of cement concrete unreinforced in ground floor and paving exc 15cm thick (below or above ground level) complete all as specified and directed. | 45 | Cum | |
23 | 23 | M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. | 7.5 | Cum | |
24 | 24 | M&L Hardcore of broken stone or boulder of guage n.exc 63 mm, deposited, spreed and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 30 | Cum | |
25 | 25 | M & L 100 mm thick Cement concrete 1:3:6 type C-2, using 40 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed. | 250 | Sqm | |
26 | 26 | M&L for 100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregates as in hard standing laid in panels and finished even and smooth without using extra cement and spike rolling to surfaces or making impression of expanded metal whilst the concrete surface is green complete all as specified and directed. | 50 | Sqm | |
27 | 27 | M & L for 20 mm thick Screed bed or bedding layer of mortar in cement mortar 1:6 for laying floor finishes complete all as specified and directed. | 150 | Sqm | |
28 | 28 | M&L chequered cement concrete tiles 20 cm X 20 cm X 25 mm thick, set , jointed and pointed in neat cement surry in floors with pigments complete all as specified and directed. | 150 | Sqm | |
29 | 29 | M&L 50 mm thick Sand cushning below interlocking paver tile complete all as specified and directed. | 5 | Cum | |
30 | 30 | M&L Machine pressed precast concrete interlocking paver block any shape and size fixing with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. | 100 | Sqm | |
31 | 31 | M&L for preparation of old decorated surfaces of walls and applying one coat of white wash complete all as specified and directed. | 10000 | Sqm | |
32 | 32 | M&L for preparation of old decorated surfaces of ceiling by brooming or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash complete all as specified and directed. | 2000 | Sqm | |
33 | 33 | M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed. | 5000 | Sqm | |
34 | 34 | M&L for preparation of old plastered surfaces on ceiling and applying one coat of oil bound distemper complete all as specified and directed. | 1000 | Sqm | |
35 | 35 | M & L for preparation of old plastered surfaces of wall and applying one coat of cement based paint complete all as specified and directed. | 5000 | Sqm | |
36 | 36 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 1200 | Sqm | |
37 | 37 | M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 1500 | Sqm | |
38 | 38 | M&L for preparation of old plastered surfaces of wall and applying one coat of weather proof exterior emultion (APEX of Asian paint or equivalent) complete all as specified and directed. | 700 | Sqm | |
39 | 39 | M&L for preparation of old treated surfaces of wall by complete removing of existing treatment and applying two coat of oil bound distemper over a coat of wall putty and primer complete all as specified and directed. | 1370 | Sqm | |
40 | 40 | M&L for preparation of old decorated surfaces of wall with complete removal of existing treatment and applying two coat of cement based paint complete all as specified and directed. | 2500 | Sqm | |
41 | 41 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 70 | Sqm | |
42 | 42 | M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement and mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.\n(Note: supply only of WPC shall be measured and paid for seperately ) | 20 | Sqm | |
43 | 43 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in two layers with 10mm thick in CM 1:6 and top 5mm thick in CM 1:4, mixing water proofing compound at 3% by weight of cement (but excluding the cost of WPC) finishing the surface even and smooth without using extra cement complete all as specified and directed. | 50 | Sqm | |
44 | 44 | Supply only integral water proofing compound complete all as specified and directed. | 23 | Kg | |
45 | 45 | Removing / taking out plants roots prtrouding from \nwall / vertical surfaces / horizontal surfaces in including removal of roots cleaning and making good by applying bonding agent algibound fepx algi coal ec 100,filling with cement mortar 1:4 with using water proofing compound complete complete all as specified and directed. (NOTE:- The quoted rate including water proofing compound) | 46 | Each | |
46 | 46 | Taking down of eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. | 38 | RM | |
47 | 47 | M&L for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls etc complete all as specified and directed. | 38 | Rm | |
48 | 48 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. | 6 | Cum | |
49 | 49 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 7 | Cum | |
50 | 50 | M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. | 7 | Cum | |
51 | 51 | M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed. | 18 | Sqm | |
52 | 52 | Mild steel TMT bars 10 mm dia and over, cut to length bend to shape required incl cranking bending and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. | 74 | kg | |
53 | 53 | Precast RCC 1:2:4 type B-1 using 20mm graded stone aggregates in cover slabs set in cement mortar 1:6 including all necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately). | 0.5 | Cum | |
54 | 54 | M&L wire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed. | 35 | Sqm | |
55 | 55 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 4 | Cum | |
56 | 56 | M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound @ 3% by weight of cement content,finished surface even and smooth with using extra cement complete all as specified and directed.\nNote : water proofing compound shall be measured seperatly. | 13 | Sqm | |
57 | 57 | M&L rendering 15mm thick cement plaster as in brick/concrete surface of sunken portion using water proofing compound @3% by the weight of cement content in cement mortar 1:3 complete all as specified and directed.\nNote : water proofing compound shall be measured & paid seperately | 35 | Sqm | |
58 | 58 | Taking down carefully old UNSV aluminium point wiring with wooden batten /concealed and all accessories of(light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturbed surface complete all as specified and directed. | 323 | Per Point | |
59 | 59 | M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC conduit duly concealed continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light/Call bell point controlled by one, one way switch. | 30 | Per Point | |
60 | 60 | One fan point controlled by one, one way switch. | 10 | Per Point | |
61 | 61 | One exhaust fan point controlled by one, one way switch. | 5 | Per Point | |
62 | 62 | One 5 Amp socket point controlled by one switch on independent board | 15 | Per Point | |
63 | 63 | One 5 Amp socket point controlled by one switch on same board | 10 | Per Point | |
64 | 64 | All as per Item No.59 above but with cable PVC insulated 4.0 Sqmm in and including PVC Conduit incl continuous earthing with cable PVC insulated 2.5 Sqmm copper conductor for power socket 15Amps complete all as specified and directed. | 10 | Per Point | |
65 | 65 | M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC casing caping duly fixed on walls continuous earthing with cable PVC insulated 1.5 Sqmm copper conductor cable for earth continuity wire , MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch. | 30 | Per Point | |
66 | 66 | One fan point controlled by one switch. | 20 | Per Point | |
67 | 67 | On 3 pin 5 Amps socket outlet point on independent board | 20 | Per Point | |
68 | 68 | On 3 pin 5 Amps socket point on the same board | 20 | Per Point | |
69 | 69 | One light point controlled by two two way switches | 5 | Per Point | |
70 | 70 | All as per Item No.65 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket complete all as specified and directed. | 20 | Per Point | |
71 | 71 | M&L for point wiring in existing conduit with PVC insulated, unsheathed, single core multistandard copper conductor cable 1.5 Sqmm, stranded copper conductor in and including PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.\n | 40 | Per Point | |
72 | 72 | One fan point controlled by one switch. | 20 | Per Point | |
73 | 73 | On 3 pin 5 Amps socket outlet point on independent board | 20 | Per Point | |
74 | 74 | On 3 pin 5 Amps socket point on the same board | 20 | Per Point | |
75 | 75 | One light point controlled by two two way switches | 8 | Per Point | |
76 | 76 | All as per Item No. 71 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket complete all as specified and directed. | 20 | Per Point | |
77 | 77 | S&F switch socket combination 2-in-1, 5 pin 5 Amp complete all as specified and directed. | 30 | Each | |
78 | 78 | S&F switch socket outlet 5 pin 5 Amp complete all as specified and directed. | 30 | Each | |
79 | 79 | S&F switch socket combination 2-in-1, 5 pin 5 and 15 Amp complete all as specified and directed. | 30 | Each | |
80 | 80 | S & F switch piano (Flush type) 5 amps, 240 Volts, single pole one way complete all as specified and directed. | 60 | Each | |
81 | 81 | S & F switch piano (Flush type) 5 amps, 240 Volts, single pole two way complete all as specified and directed. | 10 | Each | |
82 | 82 | S&F modular socket 6 A , 2/3 pin combined 2 module complete all as specified and directed. | 15 | Each | |
83 | 83 | S&F modular switch 6A complete all as specified and directed. | 20 | Each | |
84 | 84 | S&F modular switch 1 way 16A, 1 module complete all as specified and directed. | 20 | Each | |
85 | 85 | S&F modular socket 6A / 16A , 2/3 pin combined 2 module complete all as specified and directed. | 20 | Each | |
86 | 86 | S&F modular 6A 1 module 2 way switch complete all as specified and directed. | 10 | Each | |
87 | 87 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC complete all as specified and directed. | 10 | Each | |
88 | 88 | S & F for Bell push modular 6 Amps single module complete all as specified and directed. | 10 | Each | |
89 | 89 | S&F modular Ceiling rose 3 termianl complete all as specified and directed. | 10 | Each | |
90 | 90 | S&F modular white cover plate with frame for module 3 incl modular metal flush box complete all as specified and directed. | 10 | Each | |
91 | 91 | All as per Item No. 90 above but for 6 module complete all as specifed and directed. | 6 | Each | |
92 | 92 | All as per Item No. 90 above but for 8 module complete all as specifed and directed. | 4 | Each | |
93 | 93 | All as per Item No. 90 above but for 12 module complete all as specifed and directed. | 4 | Each | |
94 | 94 | All as per Item No. 90 above but for 18 module complete all as specifed and directed. | 2 | Each | |
95 | 95 | S&F Bakelite Sheet cover plate of size (5x5) complete all as specified and directed. | 30 | Each | |
96 | 96 | S&F Bakelite Sheet cover plate of size (8x5) complete all as specified and directed. | 30 | Each | |
97 | 97 | S&F Bakelite Sheet cover plate of size (11x13) complete all as specified and directed. | 30 | Each | |
98 | 98 | S& F in replacement PVC Gang box Square type for fittings complete all as specified and directed. | 50 | Each | |
99 | 99 | S& F in replacement PVC Board box of following Size complete all as specified and directed. (4x4) | 50 | Each | |
100 | 100 | All as per Item No. 99 above but (6x8) | 50 | Each | |
101 | 101 | All as per Item No. 99 above but (8x10) | 50 | Each | |
102 | 102 | S&F ceiling rose, bakelite three terminal complete all as specified and directed. | 20 | Each | |
103 | 103 | S & F bell ding dong electric single phase 240 Volt complete all as specified and directed. | 10 | Each | |
104 | 104 | S & F ceiling fan regulator electronic step type socket mounting type complete all as specified and directed. | 10 | Each | |
105 | 105 | S & F in repair LED light fitting 18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White , internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size complete all as specified and directed. | 100 | Each | |
106 | 106 | S & F in repair of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 9W cap T5(max lenght upto 600mm) complete all as specified and directed. (Note : Contractor shall submit warratny for 03 yrs) | 20 | Each | |
107 | 107 | S&F in repair LED Porch light/surface mounting downlighter type with round surface,PDC Al housing light fittings of 10 W cap 3000K incl taking down the old unsv complete all as specified and directed. (Note : must for warrenty of 3 yrs to 5 yrs) | 5 | Each | |
108 | 108 | S&F in repair recess mounting LED low profile slim fit downlights with high lumin out put of 12 wats cap with celing cutout 160mm oval/round of ht 25mm complete prewired incl necessary electrical connections complete all as specified and directed. | 5 | Each | |
109 | 109 | S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 36W, sIze 2'x2' including taking down the old rusted tube light fitting complete all as specified and directed. | 2 | Each | |
110 | 110 | S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x2' including taking down the old rusted tube light fitting complete all as specified and directed. | 5 | Each | |
111 | 111 | S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x1' including taking down the old rusted tube light fitting complete all as specified and directed. | 5 | Each | |
112 | 112 | S&F in repair Globe Decorative wall light fixture made up of Polycarbonate,suitable for LED incl LED Bulb 10W B-22 Series complete all as specified and directed. | 5 | Each | |
113 | 113 | S&F in replacement of bldg security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. mounting bracket suitable to house the light fittinhg , with its Galvanised Flat Iron clamps conntected nuts bolts etc complete all as specified & directed. (Note : must for warrenty of 3 yrs to 5 yrs) | 5 | Each | |
114 | 114 | M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 2.5 Sq mm, stranded copper conductor complete all as specified and directed. | 20 | RM | |
115 | 115 | M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 1.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.0 Sq mm, stranded copper conductor complete all as specified and directed.\nNote :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. | 20 | RM | |
116 | 116 | M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 2.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.5 Sq mm, stranded copper conductor complete all as specified and directed.\nNote :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. | 20 | RM | |
117 | 117 | M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor complete all as specified and directed.\nNote :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. | 20 | RM | |
118 | 118 | M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductor complete all as specified and directed.\nNote :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre. | 10 | RM | |
119 | 119 | S& F in replacement 3 core 1 Sqmm round Sheathed copper wire complete all as specified and directed. | 90 | RM | |
120 | 120 | S & F in replacement sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KA as incomer 4 way double door made complete all as specified and directed. | 1 | Each | |
121 | 121 | S & F in replacement sheet metal enclosure double door MCB DB, SPN 12 way complete all as specified and directed. | 2 | Each | |
122 | 122 | S & F in replacement sheet metal enclosure double door MCB DB, SPN 8 way complete all as specified and directed. | 2 | Each | |
123 | 123 | S & F in replacement sheet metal enclosure double door MCB DB, TPN 4 way complete all as specified and directed. | 2 | Each | |
124 | 124 | S & F in replacement MCCB 100 Amps 4 Pole 25 KA 415Volts complete all as specified and directed. | 1 | Each | |
125 | 125 | S & F in replacement MCCB 63 Amps 4 Pole 16 KA 415Volts complete all as specified and directed. | 1 | Each | |
126 | 126 | S & F in replacement TPN 40 Amps 415Volts complete all as specified and directed. | 5 | Each | |
127 | 127 | S & F in replacement TPN 63 Amps 415Volts complete all as specified and directed. | 5 | Each | |
128 | 128 | S & F in replacement MCB SPN 16 TO 32 Amp 10 KA 240 Volts complete all as specified and directed. | 20 | Each | |
129 | 129 | S & F in replacement MCB, SP 6 to 30 Amp 240 Volts rating complete all as specified and directed. | 30 | Each | |
130 | 130 | S&F in replacement exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed. | 5 | Each | |
131 | 131 | S & F in minor repairs to FTL fittings by replacing bi-pin holders, connectors , tube rods chokes of any type and capacity etc complete all as specified and directed. Note : Tube rods and chokes are measured separately | 30 | Each | |
132 | 132 | Supply only Electronic Ballast suitable for 36/40 watts FTL conventional light fittings complete all as specified and directed. | 5 | Each | |
133 | 133 | supply only Electronic Ballast suitable for 28 watts FTL conventional light fittings complete all as specified and directed. | 5 | Each | |
134 | 134 | Supply only tube rod 36/40 watt for 4 feet tube light fittings complete all as specified and directed. | 12 | Each | |
135 | 135 | Supply only tube rod 28 watt for 4 feet tube light fittings complete all as specified and directed. | 12 | Each | |
136 | 136 | S&F in replacement of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed. | 2 | Each | |
137 | 137 | M&L in replacement for earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipe necessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed. | 4 | Each |