Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along-Bihar

East Central Railway-ECR has published Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along. Submission Date for this Tender is 28-06-2021. Electrical Products Tenders in Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

27936513
Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along
Open Tender
Indian
Bihar
28-06-2021

Tender Details

Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery.Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery., Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- Rdso / Spn / 165 / 2012 ( Ver 3.0 ) B. Applicable Sketch No. Sdo / Ips / Pi / 4L / Nre / 001 C. Type Of Battery:300Ah Lmla Or Vrla. D. Dc-Dc Converter For Ssi / Data Logger:-Yes , All Optional Items Are Required. E. Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working : [ 12-40V, 1 Amp ] , Or [ 40-100V, 1 Amp ] , Or [ 24- 32V, 5A ] To Be Decided At The Time Of Loa. G. Type Of External & Internal Relays;24 V, Q Series Relays H. Dc-Dc Converter [ 03-6V / .1A ] 04 Nos. For Block Telephone / Mt I. Distance Between Ips Room To Asm Panel [ In Meter ] ; 50-100 Meter J.Distance Between Ips Rack & Battery [ In Meter ] 20-30 Meter. K. Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn Sub System Spares Components Qty. ( 1 ) Smps: Charger Module Module ( As Cold Standby ) 01 Module. ( 2 ) Inverter Module Module ( As Cold Standby ) 01 Module. ( 3 ) Dc-Dc Converter Dc-Dc Converter For Relay Internal Relay External And Block Line Or As Required By The Purchaser 01 Module Each. ( 4 ) Ferro-Resonant Automatic Voltage- Regulator ( Avr ) Ac Capacitor 01 Set. ( 5 ) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. ( 6 ) Transformer Modular ( As Cold Standby ) 02 Module. ( 7 ) Inverter / Smr Dc Fan 02 Nos. ( 8 ) Cells 2V Cells 05 Nos.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item Description
1Supply, installation & Commissioning of SMPS based IPS Confirming to RDSO specification No. RDSO/SPN/165/2012 (Ver.3.0) or latest Amdt. and Sketch No. SDO/IPS/PI-4L/NRE/ 001 for IPS up to 4 lines without AFTC Non-RE area along with 300 AH Low Maint. Lead Acid Battery.
2Supply, installation & Commissioning of SMPS based IPS Confirming to RDSO specification No. RDSO/SPN/165/2012 (Ver.3.0) or latest Amdt. and Sketch No. SDO/IPS/PI-4L/NRE/ 001 for IPS up to 4 lines without AFTC Non-RE area along with 300 AH Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- RDSO/SPN/165/2012 (Ver 3.0) B. Applicable Sketch No. SDO/IPS/PI/4L/NRE/001 C. Type of Battery:300AH LMLA or VRLA. D. DC-DC Converter for SSI/Data Logger:-Yes , All optional items are required. E. DC-DC Converter for Axle Counter-yes, required F. DC-DC Converter for block working :[12-40V, 1 Amp],or [40-100V, 1 Amp], or [24- 32V, 5A] to be decided at the time of LOA. G. Type of external & Internal relays;24 V, Q series relays H. DC-DC Converter [03-6V/.1A] 04 Nos. for Block Telephone /MT I. Distance between IPS Room to ASM Panel [in Meter] ; 50-100 Meter J.Distance between IPS Rack & Battery [in meter] 20-30 meter. K. Whether installation is to be done by OEM-Yes. L. Supply of Spares required as per list given below: SN Sub system Spares components Qty. (1) SMPS: Charger Module Module (as cold standby) 01 Module. (2) Inverter Module Module (as cold standby) 01 Module. (3) DC-DC Converter DC-DC Converter for relay internal relay external and block line or as required by the purchaser 01 Module each. (4) Ferro-resonant Automatic Voltage- Regulator (AVR)AC Capacitor 01 set. (5) Fuses All type of fuses used in IPS sub-system 01 set. (6 )Transformer Modular (as cold standby) 02 Module. (7) Inverter/SMR DC Fan 02 Nos. (8 ) Cells 2V Cells 05 Nos.