Uttar Pradesh Projects Corporation Limited has published Establishment Of Psa ( Pressure Swing Adsorption ) Technology To Produce Oxygen With Preventive And Corrective Maintenance Of Oxygen Plant For A Period Of 5 Years At 100 Beded Joint Hospital/Covid-19 L-2 , Hospital , Tarawan , District-Azamgarh. Submission Date for this Tender is 13-05-2021. Pure Elemental Gases Tenders in TARAWAN AZAMGARH Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: Establishment of PSA (Pressure Swing Adsorption) Technology to produce Oxygen 93% ± 3 from Ambient air having production capacity 35-50 Nm3/hr, 200 Oxygen Cylinder per day with Preventive & Corrective maintenance of oxygen plant for a period of 5 years at 100 Beded Joint Hospital/Covid-19 L-2 Hospital Tarawan, District-Azamgarh | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1.01 | Supplying, fixing & Commissioning of PSA type oxygen generator to produce Minimum 60M Cube/Hr at 93% Purity. To fill 200 cylinders of 7M Cube in 24 Hours. \n»Product flow: 60M cube/Hr at 93% Purity\n»Product Pressure: 160-155 Kg/Cmg\n»Filling Capacity: 200 Cylinder/day \n»Product Concentration (nominal) 93%\n»Product Dew Point-40 Centigrate | BI01010001010000000000000515BI0100001159 | 1 | Set |
2 | 1.02 | Supplying, fixing & commissioning of compressed air system (Air compressor) oil injected Screw Air type compressor \n»Motor KW-90\n»Rated power supply-400V AC,3 Phase, 50Hz\n»Pressure-8 Bar. \n»Air discharge capacity: 560 CFM\n»Discharge Pressure 7 BARG\n | BI01010001010000000000000515BI0100001160 | 1 | No. |
3 | 1.03 | Air receiver of 5000 litres capacity-The air receiver tank of 5000 ltrs capacity (pressure tested to two times its normal working pressure) along with auto drain valve. It should be ASME certified. | BI01010001010000000000000515BI0100001161 | 1 | No. |
4 | 1.04 | Oxygen receiveer of 5000 liters capacity The oxygen receiver tank of 5000 ltrs capacity (pressure tested to two times of its normal pressure) It should be ASME certified. | BI01010001010000000000000515BI0100001162 | 1 | No. |
5 | 1.05 | Refrigerant Air Dryer. \nCapacity-600CFM\nRating:2KW\nInlet Temperature:40degC\n | BI01010001010000000000000515BI0100001163 | 1 | No. |
6 | 1.06 | Filtration system for compressed air.\nPre filter-105 CFM@7.0 Bar Pressure. Cap-1 Micron Oil Filter-105 CFM @ 7.0 Bar Pressure. Cap-0.01 Micron.\n After filter: (0.1 Micron) working pressure max 10.0 Bar & oil Vapour filter, Dust filter, Odour Filter, Bacterial Filter | BI01010001010000000000000515BI0100001164 | 1 | No. |
7 | 1.07 | Oxygen Analyser \nOxygen measure standard: 02:0-100%\nOption: 95-100% 02 (MOQ of 100 pieces is required)\n Oxygen accuracy ± 2% FS\nFlow accuracy ±0.2Lmin\nFlow direction No limitation \nResponse time 10 sec\nMaximum inlet pressure 150kPa \nOperating termperature 0-50 Centigrate \nSpan lifetime = 1 years\nFlow sensitivity: 1-4 SCFH\n | BI01010001010000000000000515BI0100001166 | 1 | No. |
8 | 1.08 | Supplying, fixing & commissiong of Oil free Oxygen Booster system:22KW, 150 Bar g for 60M cube/Hr capacity to fill 200 cylinders of 7 M cube in 24 Hourss. | BI01010001010000000000000515BI0100001167 | 1 | Set |
9 | 1.09 | Medical Gas Alarm system. | BI01010001010000000000000515BI0100001168 | 1 | No. |
10 | 1.1 | Main Electrical Panel. | BI01010001010000000000000515BI0100001169 | 1 | No. |
11 | 1.11 | Automatic change over system. | BI01010001010000000000000515BI0100001170 | 1 | No. |
12 | 1.12 | GST Extra as applicable | BI01010001010000000000000515BI0100001171 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail