}

Work Against Sanctioned Package No. 76/2020-21 (Under Deposit Scheme) Under Electricity Urban Distribution Division-Iv, Gorakhpur, Area of EUDD-IV GKP-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Work Against Sanctioned Package No. 76/2020-21 (Under Deposit Scheme) Under Electricity Urban Distribution Division-Iv, Gorakhpur. Submission Date for this Tender is 20-05-2021. Bolts Tenders in Area of EUDD-IV GKP Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27815620
Corrigendum : Work Against Sanctioned Package No. 76/2020-21 (Under Deposit Scheme) Under Electricity Urban Distribution Division-Iv, Gorakhpur
Open Tender
Indian
Uttar Pradesh
Area Of Eudd-Iv Gkp
20-05-2021

Tender Details

Work Against Sanctioned Package No. 76 / 2020-21 ( Under Deposit Scheme ) Under Electricity Urban Distribution Division-Iv, Gorakhpur-2 Supply Of Following Material / Fitting Complete In All Respect As Per Respo Norms- 3 11 Kv Xlpe 3*185 Mm2 4 St Pole 11Mtr. Long 5 Stp 9 Mtrs Long 6 11 / .4 400 Kva Tf 7 11 Kv Top Channel 8 11 Kv Dropper Angle 9 T-Off Channel 10 11 Kv Pin Insulator With Pin 11 11Kv Cable Jointing Kit 3*185 12 11 Kv Disc Insulator With Fitting 13 Dd Wire ( Drop Down ) Compatible To Use At Ht Side Of 400 Kva Distribution T / F 14 Earthing Complete With Ms Earthing Rod Of 20X2500 Mm Amd 6 Swg Earthing Wire 15 11 Kv Straight Through Jointing Kit 16 G.I Earthing Strip 50X6 Mm 17 Stay Complete ( Stay Rod 16X1800 Mm, Stay Wire 5 Kg, Stay Clamp, Nuts & Bolts ) 18 Lt. Al. Cable 1X400 Sq Mm 19 Lt. Al. Cable 3.5*240 Sq Mm 20 Lt. Al. Cable 3.5*120 / 150 Sq Mm 21 Holding Clamp For Stps, Dropper, Top Etc 22 Lt Clamp For Existing Lt Lines 23 Nut & Bolt 24 Hdpe Pipe 160 Mm Dia Pn 6 Pe 8 Rating With Elbow And Socket 25 Shackle Insulator 26 G.I Pipe 6 Inch Dia 27 Lt Feeder Pillar A Type ( 800 Amp ) ( For Outdoor Installation Near 400 Kva T / F ) Confirming To Is: 5039-1983 / Is: 375-1963 / Is: 4217-1982 / Is: 8623-1977 With 7 Ways ( 1 No. Incomer 800Amp 35Ka Tp Mccb With Ol / Sc Protection And 6 No. Outgoing 250 Amp 25Ka Tp Mccb With Ol / Sc Protection & Metering ) 28 Lt Feeder Pillar B Type ( 250 Amp ) ( For Outdoor Installation ) Confirming To Is: 5039-1983 / Is: 375-1963 / Is: 4217-1982 / Is: 8623-1977 With 7 Ways ( 1 No. Incomer 250Amp 25Ka Tp Mccb With Ol / Sc Protection And 6 No. Outgoing 63 Amp 10Ka Tp Mccb With Ol / Sc Protection ) 29 Lt Feeder Pillar C Type ( 100 Amp ) ( For Outdoor Installation ) Confirming To Is: 5039-1983 / Is: 375-1963 / Is: 4217-1982 / Is: 8623-1977 With 16 Ways ( 4 No. Incomer 32Amp And 12 No. Outgoing 16 Amp ) 30 Al Cable 10 Sq Mm ( 2 Core ) ( Armoured ) 31 Al Cable 16 Sq Mm ( 4 Core ) ( Armoured ) 32 Al Cable 25 Sq Mm ( 4 Core ) ( Armoured ) 33 Al Cable 50 Sq Mm ( 4 Core ) ( Armoured ) 34 Hdpe Pipe 32 Mm With Elbow And Socket 35 Cable Gland For Al. Cable 3.5*120 Sq Mm ( Brass Made ) Confirming To Bs: 6121. The Cable Glands Shall Also Be Duly Tested For Dust Proof And Weather Proof Termination. 36 Cable Gland For Al. Cable 3.5*240 Sq Mm ( Brass Made ) Confirming To Bs: 6121. The Cable Glands Shall Also Be Duly Tested For Dust Proof And Weather Proof Termination. 37 Cable Gland For Al. Cable 1*400 Sq Mm ( Brass Made ) Confirming To Bs: 6121. The Cable Glands Shall Also Be Duly Tested For Dust Proof And Weather Proof Termination. 38 Al. Lugs 400 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 39 Al. Lugs 240 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 40 Al. Lugs 120 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 41 Almunium Lugs 75 Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 42 Al. Lugs 50 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 43 Al. Lugs 25 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 44 Al. Lugs 16 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 45 Al. Lugs 10 Sq Mm, Cable Lugs Shall Betinned Copper Solder Less Crimping Type Conforming To Is: 8309 And Is: 8394 Suitable For Aluminium Or Copper Conductor ( As Applicable ) . The Cable Lugs Shall Suit The Type Of Terminal Provided. The Cable Lugs Shall Be Of Dowell Make Or Equivalent. 46 Copper Z Clamp 47 Stone Pad 48 Danger Notice Plate Of Mild Steel ( 250Mmx200mmx1.6Mm ) Confirming To Is 5:1978 & Is 13410 49 Acsr Dog Conductor 50 11 Kv V Type Cross Arm 51 Lt Xlpe 3.5X400 Sq.Mm. 52 F-Bracket 53 Dressing, Marking, Tagging And Safe Laying Of 11 Kv 3X185 Sq.Mm. Xlpe Cable Under Concrete Roadside Trench With Necessary Material. Also Fabrication And Erection Of Cable Marker Of Rcc Of Dimension 1200 Mmx200 Mmx80 Mm ( Complete Work ) Around Both The Cable ( All Necessary Materials Provided By Contractor ) 54 Laying Of Hdpe Pipe 160 Mm Diameter For Laying Of 11 Kv 3X185 Sq Mm Xlpe Cable By Horizontal Drilling Method After Digging Of Kachcha / Pakka Road For Pit Including Cost Of Bricks, Sand Etc Required As Per Norms. The Hdpe Pipe Shall Be Of Pe 80 Grade With Pressure Rating Pn6 Conforming To Is 4984 / 1995 And Shall Have Wall Thickness Of 11.20 To 12.60 Mm ( All Necessary Material Will Be Supplied By Contractor ) 55 Dressing, Marking, Tagging And Safe Laying Of Under Ground 11 Kv 3X185 Sq Mm Xlpe Cable Into Hdpe Pipe By Horizontal Drilling Method As Per Respo Norms. The Depth Of Horizontal Drilling Shall Be Between 2 To 3 Meters Or As Per Site Required. 56 Dressing, Marking, Tagging And Safe Laying Of Parellel 11 Kv 3X185 Sq.Mm. Xlpe Cable ( 900 Mtr. X 2= 1800 Mtr. ) By Digging Of Trench Of Size 800 Mm Wide 1250 Mm Deep And Boxing With Brick, Sand, Stone Slab 600X450x50 Mm, Width Between 11 Kv Cable 600 Mm. ( All Necessary Materials Provided By Contractor ) . Work Will Be Done As Per Provision Of Is 1255:1983 57 Dressing, Marking, Tagging And Hoisting Of Cable On Double Pole Using G.I. Pipe 6Dia 3 Mtr. Long With Complete Work. 58 Fabrication & Erection Of Substation Double Pole Structure On 11 Mtr. Long St Pole With Fixing Of Necessary Clamps & Accessories Required Such As Top Channel, Pin Insulator Etc Including Digging Of Pit 2 Mtr. As Well As Grouting And Plinthing Of St Pole ( Size Of The Pole Plinth Is Kept As 450X450 Mm X Depth And Height 300 Mm Above Ground Level With Top 100 Mm Is Kept Tapered So That No Rainwater Gets Accumulated On The Top ) With 1:4:8 Cc Ratio Of Cement, Sand & Brick Ballast, Backfilling Of Pits With Mud Completely ( As Per Respo Norms ) . All Required Materials Will Be Provided By The Contractor. 59 Fabrication & Erection Of Single 9 Mtr. / 11 Mtr. Long St Pole With Fixing Of Necessary Clamps & Accessories Required Including Digging Of Pit Depth 1 / 6 Of The Length Of Pole As Well As Grouting And Plinthing Of St Pole ( Size Of The Pole Plinth Is Kept As 450X450 Mm X Depth And Height 300 Mm Above Ground Level With Top 100 Mm Is Kept Tapered So That No Rainwater Gets Accumulated On The Top ) With 1:4:8 Cc Ratio Of Cement, Sand & Brick Ballast, Backfilling Of Pits With Mud Completely ( As Per Respo Norms ) . All Required Materials Shall Be Provided By The Contractor. 60 Painting Of Pole By Double Coating Aluminium & Red Oxide Paint. Paint Will Be Provided By Contractor 61 Earthing Of St Pole By Ms Earthing Rod & 6 Swg Earthing Wire As Per Respo Norms. 62 Erection And Grouting Of Stay In Cc Ratio 1:4:8 Of Cement, Sand And Stone Ballast Including Cost Of Grouting Material With Nozelling And Binding Of Stay Wire ( Complete Work ) 63 Construction Of T / F Plinth Of Size 2X2x1.2 Mtr With The Help Of First Class Brick & 9 Masonary In The Ratio 1:4 Cement & Sand Coarse. Filling The Structure Completely And Plastering Outer Surface As Per Respo Norms. Top Of The Plinth Covered With 4 Rcc Slab Of Ratio 1:1.5:3 ( Cement, Sand & Concrete ) Grouting With 2 Nos. Ismc Size 125X65x6 Mm ( Confirming To Is 808:1989 ) Of 2000 Mm Long For Resting. All Required Materials Will Be Provided By The Contractor. 64 Grill Fencing Of 11 / 0.4 Kv S / S Shall Be Made Of Rectangular Of Size & Height Approx 2 Meter As Per Site Requirement With Fabrication 50X50x5 Mm Angel The Frame Is Also Have 1 No. Horizontal Runner Of Ms Flat 40X5 Welded In Middle To Support Of Grill, Having A Gate On Road Side Must Have Provision Of Locking Arrangement. The Work Is Including Painting Of Fencing As Per Norms. Work Will Be Done As Per Respo Specification. 65 Fabrication, Errection, Commissioning & Testing Of 400 Kva T / F On Double Pole With All Accessories Including Make Its Lt And Ht Connection. All Neessary Materials Will Be Supplied By The Contractor. 66 Chemical Earthing Of Transformer ( Body+Neutral ) As Per Is Code 3043 - 1987 Specification 67 Errection Of 11 Kv 3X185 Mm² Xlpe Cable Jointing Kit Indoor / Outdoor With Complete Work 68 Errection Of 11 Kv Straight Through With Complete Work 69 Supply & Erection Foundation & Support Structure Of Lt Feeder Pillar A Type Along With Grouting And Muffing As Per Site Requirement ( All Required Material Will Be Provided By Contractor ) 70 Supply & Erection Foundation & Support Structure Of Lt Feeder Pillar B Type Along With Grouting And Muffing As Per Site Requirement ( All Required Material Will Be Provided By Contractor ) 71 Supply & Erection Foundation & Support Structure Of Lt Feeder Pillar C Type Along With Grouting And Muffing As Per Site Requirement ( All Required Material Will Be Provided By Contractor ) 72 Chemical Earthing Of Lt Feeder Pillar Type A As Per Is Code 3043 - 1987 Specification 73 Pipe Earthing For Lt Feeder Pillar B Type ( 250 Amp ) 74 Earthing Of Type C Panel By Ms Earthing Rod And G.I Earthing Strip 50X6 Mm As Per Respo Norms. 75 Preparing The Single / Three Phase Electronic Meter By Fixing Plastic / Hologram Seals And Entering Meter Data On Meter Register And Then Marking The Lab Meter No. On Meter Cover With Permanent Marker Pen And Then Cartaging The Meter From The Test Lab To Site Of Work As Per Direction Of Supervising Engineer Including The Work Of Loading, Unloading & Stacking The Meter At The Respective Ends And Also Including The Cost Of Arrangement Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. ( Meter Provided By Department ) 76 Replacement / Installation Of Single Phase Electronic Meters On Connections At The Outside The Main Gate Of Permises Of The Consumer Including The Work Of Sealing The Meter And Filling Of Sealing Certificate Properly And Handing Over Copy Of Sealing Certificate To Consumer And Concerned Division / Subdivision On Same Day. 77 Replacement / Installation Of Three Phase Electronic Meters On Connections At The Outside The Main Gate Of Permises Of The Consumer Including The Work Of Sealing The Meter And Filling Of Sealing Certificate Properly And Handing Over Copy Of Sealing Certificate To Consumer And Concerned Division / Subdivision On Same Day. 78 Disconnection And Re-Connection Of Consumer Cable Of Complete Lt Line ( Single / Three Phase ) 79 Laying Of Hdpe Pipe 32 Mm Diameter Along With Laying Of Al Cable 10 Sq Mm ( 2 Core ) ( Armoured ) / Al Cable 16 Sq Mm ( 4 Core ) ( Armoured ) / Al Cable 25 Sq Mm ( 4 Core ) ( Armoured ) / Al Cable 50 Sq Mm ( 4 Core ) ( Armoured ) As Applicable Through It By Horizontal Drilling Method With All Necessary Fitting. The Hdpe Pipe Shall Be Of Pe 100 Grade With Pressure Rating Pn10 Conforming To Is 4984 / 1995 And Shall Have Wall Thickness Of 3.60 To 4.20 Mm ( All Necessary Material Will Be Supplied By Contractor ) 80 Fabrication, Errection & Commissioning Of Danger Notice Plate With All Accessories 81 Laying Of Hdpe Pipe 160 Mm Diameter Along With Laying Of Lt Al. Cable 1X400 Sq.Mm. And 3.5X240 Sq.Mm. As Applicable Through It By Horizontal Drilling Method With All Necessary Fitting. The Hdpe Pipe Shall Be Of Pe 80 Grade With Pressure Rating Pn6 Conforming To Is 4984 / 1995 And Shall Have Wall Thickness Of 11.20 To 12.60 Mm ( Hdpe Pipe 160Mm Dia With Elbow And Socket For 11 Kv Cable And Other Material Will Be Supplied By Contractor ) 82 Dressing, Marking, Tagging And Safe Laying Of Lt Al. Cable 1X400 Sq.Mm. In Concrete Roadside Trench With Necessary Materials. 83 Dressing, Marking, Tagging And Safe Laying Of Lt Al. Cable 3.5X240 Sq.Mm. In Concrete Roadside Trench With Necessary Materials. 84 Dressing, Marking, Tagging And Safe Laying Of Lt Al. Cable 3.5X120 Sq.Mm. In Concrete Roadside Trench With Necessary Materials. 85 Laying, Stringing, Sagging, Binding And Jumpering Of Acsr Dog Conductor For Lt / Ht Line With Fixing Of Lt Clamps / Other Clamps, Shackle Insulator, Nuts&Bolts Off Sizeand Other Necessary Materials As Per Required. 86 Laying, Stringing And Hanging Of Lt 3.5X400 Sq Mm Xlpe Cable As Per Respo Norms. 87 Earthing Of Angles In Trench By Ms Earthing Rod And G.I Earthing Strip 50X6 Mm As Per Respo Norms. 88 Dismantling Of Following Line Materials And Safe Loading, Unloading And Carraige Of Dismantled Material From Work Site To Departmental Store ( As Per Site Requirement ) 89 Stp Pole 11 / 9 Meter Long 90 Acsr Dog / Weasel Conductor 91 11 / 0.4 250 Kva T / F ( Used ) 92 Old Energy Meter ( Single / Three Phase ) From Consumer Premises ( Old Meter Along With Overhead Service Cable Taken Out From Consumers Premises Shall Be Properly Sealed And Deposited To Electricity Urban Test Lab, Gorakhpur By The Contractor. ) 93

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 13-05-2021 TIME EXTENSION Date 20-05-2021

Key Value

Document Fees
INR 11800 /-
EMD
INR 1012000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail