Procurement Of Soft Starter, Meters & Earth Leakage Relay-Karnataka

Karnataka Power Corporation Limited has published Procurement Of Soft Starter, Meters & Earth Leakage Relay. Submission Date for this Tender is 13-05-2021. Screws Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

27776304
Procurement Of Soft Starter, Meters & Earth Leakage Relay
Tender
Indian
Karnataka
13-05-2021

Tender Details

Procurement Of Soft Starter, Meters & Earth Leakage Relay 1. 18W Led Hl Lamp Energy Efficient 18W Led Pl Lamp As Per Is: 16102 & Iec 60598-1 Technical Specifications: Main Housing / Heat Sink Material: Aluminium Extrusion Front Cover: Opal Glare Free Pc Diffuser Base: 2G11 (4 Pin) Led: Lm80 Certified Led Led Lumen Maintanance: 50,000 Hours @ L70 Control Gear: Inbuilt Cc Driver Internal Wiring: Insulated Cu Wire Hardwareâ¿S: Ss & Ms Zinc Plated And Passivated Ingress Protection: Ip20 Operating Voltage: 140V~270V Operating Temperature: -10?C~ 50?C Approx. Length: 423.6Mm(Tolerance: ±3Mm) System Current: <92Ma System Lumen Efficacy: >90Lum/W Make:Bajaj/Cgl/Philips/Havells/Halonix/Wipro, 2. Multi Data Meter Lg+ 5310 Multi Data Meter Model: Lg+ 5310 Rs485 Class:1.0 Size: 96X96/96X48 Parameters: Vll, Vln, Amp, Hz, W, Pf, Va,Wh, Lh&Oh, Old Energy Sl.No: Hbg 1237418 Make: Elmeasure/Prok Dvs, 3. Pse72-600-70 Soft Starter Softstarter Pse72-600-70 Of Abb Make For 37Kw Motor For Max 600V Main Voltage And 100 - 250V 50/60Hz Control Supply Voltage. Width X Height X Depth Or Length:90Mm X 245Mm X 184Mm Rated Operational Voltage:208 To600v Ac Rated Control Supply Voltage (Us):100-250V Ac Rated Control Circuit Voltage (Uc):Dc Operation 24 V Rated Frequency (F):50/60 Hz, Main Circuit 50/60 Hz Rated Operational Power - In-Line Connection (Pe):(230 V) 18.5 Kw, (400 V) 37 Kw, (500 V) 45 Kw Rated Operational Current - In-Line Connection (Ie):72 A Service Factor Percentage:100 Precent Overload Protection:Build-In Electronic Overload Protection Integrated Electronic Overload:Yes Adjustable Rated Motor Current Ie:30 To 100 Percent Starting Capacity At Maximum Rated Current Ie:4Xie For 10S Ramp Time:0 ... 30 Second [Unit Of Time] 1 ... 30 Second [Unit Of Time] Initial Voltage During Start:30 ... 70 Percent Step Down Voltage Special Ramp:No Percent Current Limit Function:1.5 ... 7Xie Switch For Inside Delta Connection:No Run Signal Relay:Yes By-Pass Signal Relay:Yes Fault Signal Relay:Yes Overload Signal Relay:Yes Analog Outputs:4 To 20 Ma Signal Indication Completed Start Ramp (Led):Green Signal Indication Ready To Start/Standby On (Led):Green Signal Indication Running R (Led):Green Signal Indication Ramping Up/Down (Led):Green Signal Indication Protection (Led):Yellow Signal Indication Fault (Led):Red Number Of Starts Per Hour At 3.5 X Ie For 7 Sec. 50 Percent On Time 50 Percent Off Time:10 Communication:Filedbusplug(Optional) Degree Of Protection:Ip00 Terminal Type:Screw Terminals Connecting Capacity Main Circuit:Rigid 1/2 X 2.5 ... 70 Sq Mm Connecting Capacity Control Circuit:Rigid 1 X 2.5Sq Mm Rigid 2 X 1.5 Sqmm Connecting Capacity Supply Circuit:Rigid 1 X 2.5Sq Mm Tightening Torque:Control Circuit 0.5 Nm, Main Circuit 9 Nm, Supply Circuit 0.5 Nm Ambient Air Temperature:Operation -25 ... +60 Deg Storage -40 ... +70 Deg, 4. Pse60-600-70 Soft Starter Abb Make Pse60-600-70 Soft Starter For 30Kw Motor. Technical Specifications Are As Follows,Width X Height X Depth Or Length = 90Mm X 245Mm X 184Mm Rated Operational Voltage:208 To 600V Ac Rated Control Supply Voltage (Us):100 To 250 V Ac Rated Control Circuit Voltage (Uc): Dc Operation 24 V Rated Frequency (F):50/60 Hz Rated Operational Power - In-Line Connection (Pe):(230 V) 15 Kw, (400 V) 30 Kw, (500 V) 37 Kw Rated Operational Current - In-Line Connection (Ie):60 A Service Factor Percentage:100 % Overload Protection:Build-In Electronic Overload Protection Integrated Electronic Overload:Yes Adjustable Rated Motor Current Ie:30 ... 100 % Starting Capacity At Maximum Rated Current Ie:4Xie For 10S Ramp Time:0 ... 30 Second [Unit Of Time], 1 ... 30 Second [Unit Of Time] Initial Voltage During Start:30 ... 70 Percent Step Down Voltage Special Ramp:No Percentage Current Limit Function:1.5 ... 7Xie Switch For Inside Delta Connection:No Run Signal Relay:Yes By-Pass Signal Relay:Yes Fault Signal Relay:Yes Overload Signal Relay:Yes Analog Outputs:4 20 Ma Signal Indication Completed Start Ramp (Led):Green Signal Indication Ready To Start/Standby On (Led):Green Signal Indication Running R (Led):Green Signal Indication Ramping Up/Down (Led):Green Signal Indication Protection (Led):Yellow Signal Indication Fault (Led):Red Number Of Starts Per Hour At 3.5 Ie For 7 Sec. 50 Percent On Time 50 Percent Off Time:10 Communication:Filedbusplug(Optional) Degree Of Protection:Ip00 Terminal Type:Screw Terminals Connecting Capacity Main Circuit:Rigid 1/2 X 2.5 ... 70 Sqmm Connecting Capacity Control Circuit:Rigid 1 X 2.5 Sqmm, Rigid 2 X 1.5 Sqmm Connecting Capacity Supply Circuit:Rigid 1 X 2.5 Mm Sq Tightening Torque: Control Circuit 0.5Nm Main Circuit 9 Nm. Supply Circuit 0.5Nm Ambient Air Temperature: Operation -25 To +60 Storage -40 To +70, 5. Iearth Leakage Relay With Cbct Intelligent Earth Leakage Relay Model No: Ielr-Cbct -Id200mm Operating Temperture: -10 To 55 Deg C Protection Grade: Ip51 Input Range: 300Ma To 12A Round Diameter: 40 To 300Mm Rectangular Diameter: 150X50, 250X100 Mm Sl.No.Hbg1232102 Make: Elmeasure/Prok Dvs,

Key Value

Document Fees
INR 550 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail