| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | item1 | 17.719 | cum |
|---|
| 2 | 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) excluding cost of cement. | item2 | 5.568 | cum |
|---|
| 3 | 3 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) excluding the cost of cement. | item3 | 8.356 | cum |
|---|
| 4 | 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of cement, reinforcements, centering, shuttering and finishing- All work up to plinth level; 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | item4 | 4.772 | cum |
|---|
| 5 | 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing, cement and reinforcement; 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) | item5 | 1.126 | cum |
|---|
| 6 | 6 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Thermo - Mechanically Treated bars of grade Fe-500D or more, excluding cost of steel reinforcements. | item6 | 589 | kg |
|---|
| 7 | 7 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | item7 | 11.761 | sqm |
|---|
| 8 | 8 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | item8 | 16.92 | sqm |
|---|
| 9 | 9 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | item9 | 12.712 | sqm |
|---|
| 10 | 10 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete excluding cost of cement. | item10 | 7.086 | cum |
|---|
| 11 | 11 | 12 mm cement plaster finished with a floating coat of neat cement of mix including all tools and tackles,labour charges,necessary scaffolding,curing etc completed all heights,except cost of cement.; 1:4 ( 1 cement : 4 fine sand) | item11 | 97.751 | sqm |
|---|
| 12 | 12 | Providing and laying vitrified/digital floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with tile joint fillers of matching shades etc., complete. Size of Tile 1200 x 600 mm or nearest. The required cement for base preparation shall be supplied by the company. | item12 | 24.36 | sqm |
|---|
| 13 | 13 | Providing and laying Polished Granite 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with granite fillers of matching shade including rubbing, curing, polishing,edge moulding/nosing etc. all complete as specified and as directed by the Engineer-in-Charge.Cement shall be supplied by the company | item13 | 9.65 | sqm |
|---|
| 14 | 14 | Supplying and filling with red earth in plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering. | item14 | 11.88 | cum |
|---|
| 15 | 15 | Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand): Flush/ Ruled pointing excluding cost of cement | item15 | 10.261 | sqm |
|---|
| 16 | 16 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | item16 | 97.751 | sqm |
|---|
| 17 | 17 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses,post of Tata structura YST 210 or like as approved including cutting, hoisting,fixing in position including welding and bolted with special shaped washers etc. complete | item17 | 589.908 | kg |
|---|
| 18 | 18 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | item18 | 40.118 | sqm |
|---|
| 19 | 19 | Providing and fixing Cement board (High Pressure steam cured) as per IS : 14862, with suitable screws etc. complete (frame work to be paid separately) :<br>8 mm thick cement board | item19 | 53.641 | sqm |
|---|
| 20 | 20 | Providing and fixing Shingles of approved colour on the top of cement board roofing including ridges with suitable screws etc. complete as per the direction of Engineer-in-charge. Use St.gobain/Gaff etc | item20 | 53.641 | sqm |
|---|
| 21 | 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | item21 | 82.312 | kg |
|---|
| 22 | 22 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | item22 | 84.181 | kg |
|---|
| 23 | 23 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):; With toughened glass 12 mm thickness | item23 | 7.14 | sqm |
|---|
| 24 | 24 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes | item24 | 2.25 | sqm |
|---|
| 25 | 25 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm | item25 | 8 | no |
|---|
| 26 | 26 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | item26 | 4 | no |
|---|
| 27 | 27 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | item27 | 4 | no |
|---|
| 28 | 28 | Providing and fixing false ceiling at all height including providing; fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with 9 mm thick TKT PVC ceiling panel sheet | item28 | 34.32 | sqm |
|---|