Military Engineer Services-MES has published Repair Maintenance External Elect , Amc Of Fire Fighting , Fire Alarm , Amr Elect Energy Meter And Other Misc Items At 13 Brd And 16 Brd Under Under Ge ( P ) Af Gurgaon. Submission Date for this Tender is 21-04-2021. Fire Alarm Systems Tenders in GE (P) AF GURGAON Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-04-2021 |
Name of Work: Repair maintenance external elect, AMC of fire fighting, fire alarm, AMR elect energy meter and other misc items at 13 BRD & 16 BRD under under GE (P) AF Gurgaon | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed. | 123 | Cum | |
2 | 2 | Demolition of PCC of any description and in any position not otherwise specifically provided complete all as specified and as directed. | 2 | Cum | |
3 | 3 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid & tested complete all as specified and directed. | 64 | Cum | |
4 | 4 | Removal of excavated surplus soil to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. | 59 | Cum | |
5 | 5 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable i.e total 23 cm complete all as specified and as directed. | 49 | Cum | |
6 | 6 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed. | 3500 | Each | |
7 | 7 | M&L for precast concrete cover class HV type 1, flat size 300mmx180mmx40mm laid in trenches for cable protection complete all as specified and directed . | 450 | Each | |
8 | 8 | Laying only old but serviceable precast concrete cover class HV type, flat size 300 mm X 180 mm X 40 mm in trenches for cable protection with cable cover retrieved from srl No 1 here in before complete all as specified and directed. | 50 | Each | |
9 | 9 | M&L for drilling hole under hard standing /road for laying of pipe for protection of cable etc by means of mannual bookie and without disturbing the top surface and making good the disturbed surface if any complete all as specified and directed. | 48 | RM | |
10 | 10 | Taking out unserviceable underground GI pipe laid for LT cable protection of following sizes | |||
11 | 10.01 | 50mm bore | 24 | RM | |
12 | 10.02 | 80mm bore | 24 | RM | |
13 | 11 | S&F GI Tubing light grade of size 80mm bore for LT cable protection complete all as specified and directed. | Each time cleaning shall be counted as one Job. | 24 | RM |
14 | 12 | S&F GI Tubing light grade of size 50mm bore for LT cable protection complete all as specified and directed. | 24 | RM | |
15 | 13 | Laying old serviceable bricks (retrieved under item 01 of Sch ‘A’.com complete all as specified and directed. | 500 | Each | |
16 | 14 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area of 50 Sqmm 3.5 Core complete all as specified and directed.\n | 150 | RM | |
17 | 15 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 95 Sqmm 3.5 Core complete all as specified and directed.\n | 100 | RM | |
18 | 16 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 120 Sqmm 3.5 Core complete all as specified and directed.\n | 80 | RM | |
19 | 17 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 185 Sqmm 3.5 Core complete all as specified and directed.\n | 50 | RM | |
20 | 18 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 240 Sqmm 3.5 Core complete all as specified and directed.\n | 40 | RM | |
21 | 19 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 300 Sqmm 3.5 Core complete all as specified and directed.\n | 35 | RM | |
22 | 20 | Supply and laying or fixing or passing through pipe cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area of 400 Sqmm 3.5 Core complete all as specified and directed.\n | 20 | RM | |
23 | 21 | Supply and laying or fixing or passing through pipe cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross-sectional area of 120 Sqmm 3 Core complete all as specified and directed.\n\n | 35 | RM | |
24 | 22 | Supply and laying or fixing or passing through pipe cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross-sectional area of 185 Sqmm 3 Core complete all as specified and directed.\n\n | 30 | RM | |
25 | 23 | Supply and laying or fixing or passing through pipe cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross-sectional area of 240 Sqmm 3 Core complete all as specified and directed.\n\n | 25 | RM | |
26 | 24 | Taking out old serviceable /unserviceable underground cable of following sizes from excavated trenches /pipes (Earth work, segregating cable cover measured and paid separately under respective item of this). | |||
27 | 24.01 | 50 Sqmm 3.5 core. | 150 | RM | |
28 | 24.02 | 95 Sqmm 3.5 core. | 100 | RM | |
29 | 24.03 | 120 Sqmm 3.5 core. | 80 | RM | |
30 | 24.04 | 185 Sqmm 3.5 core. | 50 | RM | |
31 | 24.05 | 240 Sqmm 3.5 core. | 40 | RM | |
32 | 24.06 | 300 Sqmm 3.5 core. | 35 | RM | |
33 | 24.07 | 400 Sqmm 3.5 core. | 20 | RM | |
34 | 24.08 | 120 Sqmm 3 core. | 35 | RM | |
35 | 24.09 | 185 Sqmm 3 core. | 30 | RM | |
36 | 24.1 | 240 Sqmm 3 core. | 25 | RM | |
37 | 25 | S&F aluminium lugs after disconnecting from panel and taking down burnt cable from panel of different location and cutting out the burnt portion of cable and extended the cable from cable loop, preparation of cable including necessary connection and testing complete of following sizes :- | |||
38 | 25.01 | 10 Sqmm 2/4 core 1100 volt grade | 10 | Each Job | |
39 | 25.02 | 16 Sqmm 2/4 core 1100 volt grade | 70 | Each Job | |
40 | 25.03 | 25 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
41 | 25.04 | 35 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
42 | 25.05 | 50 Sqmm 3.5 core 1100 volt grade | 60 | Each Job | |
43 | 25.06 | 95 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
44 | 25.07 | 120 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
45 | 25.08 | 240 Sqmm 3.5 core 1100 volt grade | 30 | Each Job | |
46 | 25.09 | 300 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
47 | 25.1 | 400 Sqmm 3.5 core 1100 volt grade | 50 | Each Job | |
48 | 25.11 | 185 Sqmm 3 core 11000 volt grade | 30 | Each Job | |
49 | 25.12 | 240 Sqmm 3 core 11000 volt grade | 15 | Each Job | |
50 | 25.13 | 300 Sqmm 3 core 11000 volt grade | 10 | Each Job | |
51 | 26 | Dismantling of mechanism system of defective 11 KV VCBs, repair/replace the unserviceable items such as closing/triping coil, vaccum interrupter tube,moving contact and spring charging motor etc including overhauling the same by the service engineer after necessary cleaning with CTC, and providing silicon grease to the all moving parts including adjustment of all springs etc and made 100% serviceability and testing complete all as specified and directed.\nNote:- Closing/triping coil,vaccum interruptertube,moving contact and spring charging motor shall be measured and paid separately. | 14 | Each Job | |
52 | 27 | Supply only closing/triping coil suitable for 11 KV VCB's complete all as specified and directed. \n Make:- Crompton Greaves/Areva/ABB/Schneider. | 6 | Each | |
53 | 28 | Supply only spring charging motor of 230 volts 0.25 HP, 8000 RPM suitable for 11 KV VCB's complete all as specified and directed. \nMake:- Crompton Greaves/Areva/ABB/Schneider. | 5 | Each | |
54 | 29 | Supply only vacuum interrupter tube suitable for 11 KV VCB's complete all as specified and directed. \n Make:- Crompton Greaves/Areva/ABB/Schneider. | 1 | Set of 3 | |
55 | 30 | Supply only moving contact top/bottom suitable for 11 KV VCB's complete all as specified and directed. \n Make:- Crompton Greaves/Areva/ABB/Schneider. | 7 | Each | |
56 | 31 | Taking out of defective /unserviceable /obsolete model indicator lamp from 11 KV VCB's, supply and fixing indicator lamp LED type of different colour of existing, 60 mm dia 30 volts complete all as specified and directed. \nMake - Siemens/L&T/ABB/CG/Schneider) | 25 | Each | |
57 | 32 | Supply & fixing busbar insulators suitable for 11 KV VCB's Make -As per sample | 12 | Each | |
58 | 33 | S&F DC power pack 230 VCA +- 10%, 50Hz 24 V DC/26AHDC complete all as specified and directed.\n | 3 | Each | |
59 | 34 | Taking out of old unserviceable/defective/old vintage/ obsolete model of relays from 11 KV VCB's and Supply and fixing over current and earth fault electronic relay.\nMake - L&T Cat No- MC61A-nX2200 suitable for 11 KV VCB like as CG/ABB/Areva including necessary addition/ alternation of VCB front panel including cutting/welding of front side of panel board to match & fixed the new relays to the existing panel board/position including necessary touch up to the panel board complee all as completed testing of over load and earth fault protection all as directed. | 8 | Each Job | |
60 | 35 | Supply and installation of 11 KV single phase in door resin cast PT of ratio 11 KV/rt3/110v/rt3,class 0.5-3,burden 50 VA-50VA all as specified and directed. | 1 | Set of 3 | |
61 | 36 | Supply and installation of 11 KV single phase in door resin cast CT of ratio 100/50/5 amps (dual core - one for metering and other for protection) having 16 VA burdon and class 5P-10 protection complete all as specified and directed.\n | 3 | Set of 3 | |
62 | 37 | Taking out of Air Circuit Breaker LT 415 volts up to 800 amps from existing position, dismantling the same, overhauling/maintenance/repair the same including replacement of minor spares and assembling the same refixing to the existing position including adjustment of load and testing complete all as specified and directed.\n | 2 | Each Job | |
63 | 38 | Supply and laying of 2.5 mm thick insulated synthetic mat of confirming to IS 15652:2006 and meeting the requirements of IS 5216 (Part 1.2 & 3) IS 8437, IFC-479 Pub-1, alongwith suitable adhesive/chemibound, PU resin, waterproofing compound and sealing material as per in service recommendation of IS : 15652 class – B suitable for working voltage up to 11 KV with trolley movement complete all as specified and directed.\n | 10 | Sqm | |
64 | 39 | S&F in replacement of mild steel chequered plates 5 mm thick or over in thickness avilable size duly painted with two coat of black bituminous paint over one coat of red oxide primer and cut to shape for cable duct complete all as specified and directed. | 165 | Kg | |
65 | 40 | S&F Volt meter (0-500) digital square flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable one complete all as specified and directed. Make: L&T/AE/Schneider | 4 | Each | |
66 | 41 | S&F Ammeter (0 - 200 A) digital square flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable one complete all as specified and directed.\nMake: L&T/AE/Schneider | 3 | Each | |
67 | 42 | All as per srl item No. 41 but 0-100 A . | 3 | Each | |
68 | 43 | All as per srl item No. 41 but 0-75 A . | 3 | Each | |
69 | 44 | M&L for complete overhauling RMU unit of make AREVA by opening the front and rear cabinate of the RMU 4 way 630 Amps 11 KV de-carbonizing moving and fixed contacts if required, lubricating, checking/charging the SF-6 gas, calibration of micro processor EF/OC relay, tripping coil electrical and checking serviceability of all manual/auto tripping system complete and placing the SF-6 VCB and isolating unit in its original position complete all as specified and as directed.\nNote:- (i) Any spares or consumables required other than item No. 43 to 44 for serviceability of RMU with SF-6 shall be provided by the contractor. The rate for the same is included in rate quoted by the contractor. (ii) After excecution of item No. 42 above contracor shall provide assurance certificate for serviceabilty of the entire RMU unit till completion of the work. | 1 | Each Job | |
70 | 45 | Supply only current transformer as per existing type & make for SF-6 Ring Main unit by opening the cable compartment cover of fixed the CT on cable elbow plug/T plug complete all as specified and directed. | 1 | Each | |
71 | 46 | Supply only SF-6 gas in safe ring/safe plus by SF-6 gas bottle by removing front cover and on screw manometer and reduction valve and maintained the pressure 14 bar obslute complete all as specified and directed. | 1 | Kg | |
72 | 47 | M&L for painting to electrical equipments steel sections, rolling shutters etc with one coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces complete all as specified and directed. | 45 | Sqm | |
73 | 48 | M&L for spray painting outside for 11 KV VCB's panel/bus copler with one coat of synthetic enamel paint Ist grade (moisture proof) after preparation/cleaning of steel surfaces as specified and directed. \nMake - Asian paints/Berger Paints/Neroac Paints | 9 | Each Job | |
74 | 49 | M&L for painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove iol stains dust etc. and applyinbg one coat of synthetic enamel paint by spray paint including writing SM No / MES No capacity of transformer for transformer of 100 KVA to 150KVA capacity complete all as specified and directed. Make - Asian paints /Berger Paints/Neroac Paints | 4 | Each Job | |
75 | 50 | M&L for spray painting to LT panel board with one coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces and welding work as required complete all as specified and directed. (approximate 8 sq mtr of each panel board ) Make - Asian paints /Berger Paints/Neroac Paints | 17 | Each | |
76 | 51 | Supply and laying of round boulders of gauge 63 mm graded as in bedding layer around electrical equipment or installation , transformer etc complete all as specified and directed. | 12 | CUM | |
77 | 52 | M&L for defect rectification of electric LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable, treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge. | 8 | Each Fault | |
78 | 53 | Supply and jointing indoor/outdoor LT cable end terminal joints/straight through heat shrinklabe type complete suitable for aluminium conductor cable of size 2/4 Core upto 16 Sqmm complete all as specified and as directed.\nMake: Denson/Cabseal/M-Seal | 3 | Each | |
79 | 54 | All as per item No 53 but for cable of size 25 Sqmm 3½ Core to 95 Sqmm 3½ Core. | 13 | Each | |
80 | 55 | All as per item No 53 but for cable of size 120 Sqmm 3½ Core to 240 Sqmm 3½ Core. | 9 | Each | |
81 | 56 | All as per item No 53 but for cable of size upto 400 Sqmm 3½ Core. | 5 | Each | |
82 | 57 | M&L for defect rectification of electric HT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 300 Sq mm 3 core. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge. | 7 | Each Fault | |
83 | 58 | Supply & fixing cable jointing kit and testing complete for 11 KV grade HT cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 300 sqmm complete all as specified and directed. Make: Denson/Cabseal/M-Seal | 4 | Each | |
84 | 59 | All as per item No 58 but indoor type | 10 | Each | |
85 | 60 | All as per item No 58 but straight through | 8 | Each | |
86 | 61 | Supply only Internal wiring for panel with copper conductor insulated, (FRLSH) 10 Sqmm single core complete all as specified and as directed by Engr-in-charge. | 100 | RM | |
87 | 62 | Disconnecting of both HT and LT connection from cable end box and taking down the disconnected transformer (Out door type/ indoor type) from platform with the help of HOT crane, chain pulley and other T&P relevent to site, and transportation of complete unserviceable transformer to workshop in a vehicle capable of carrying upto 5 Tons and a distance of workshop not more then 15 Kms from the existing site including loading unloading of transformer unit of capacity 150 KVA to 1500 KVA and brought back to same or other location as directed by Engr-in-chgarge, placed in position, connection and testing including manpower and machineries/T&P complete all as specified and as directed by Engr-In-Charge. | 2 | Each Job | |
88 | 63 | M&L for rewinding of HT/LT coils of transformer of capacity 150 KVA to 1500 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish, heating/drying etc complete all as specified and directed. Note :- (i) Transformer rewinding will be done at workshop of approved manufacturer available in CE zone list. (ii) Transformer will be inspected by ref of CWE TKD before and after repair. | 495 | Kg | |
89 | 64 | Supply only breather assembly of existing make filled with silica gel suitable for transformer upto 150 KVA capacity complete all as specified and as directed. | 1 | Each | |
90 | 65 | All as per item No.64 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 1 | Each | |
91 | 66 | All as per item No. 64 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 2 | Each | |
92 | 67 | Supply only brass terminal on HT side threaded complete with nut washers etc of suitable dia for transformer upto 150 KVA capacity complete all as specified and as directed by Engr-in-charge. | 3 | Each | |
93 | 68 | All as per item No. 67 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 5 | Each | |
94 | 69 | All as per item No. 67 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 3 | Each | |
95 | 70 | Supply only brass terminal on LT side threaded complete with nut washers etc of suitable dia for transformer upto 150 KVA capacity complete all as specified and as directed by Engr-in-charge. | 1 | Each | |
96 | 71 | All as per item No. 70 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 3 | Each | |
97 | 72 | All as per item No. 70 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 2 | Each | |
98 | 73 | Supply only ceramic bushing on HT side transformer upto 150 KVA capacity complete all as specified and as directed by Engr-in-charge. | 3 | Each | |
99 | 74 | All as per item No. 73 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 4 | Each | |
100 | 75 | All as per item No. 73 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 2 | Each | |
101 | 76 | Supply only arc horn surge arrestor complete with mounting ring nut transformer upto 150 KVA capacity complete all as specified and as directed. | 6 | Each | |
102 | 77 | All as per item No. 76 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 8 | Each | |
103 | 78 | All as per item No. 76 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 4 | Each | |
104 | 79 | Supply only gasket set for top lid cover LT and HT terminal bushing suitable for transformer upto 150 KVA capacity complete all as specified and as directed. | 2 | Each Set | |
105 | 80 | All as per item No. 79 hereinbefore but for transformer capacity 200 KVA to 400 KVA . | 3 | Each Set | |
106 | 81 | All as per item No. 79 hereinbefore but for transformer capacity 500 KVA to 1500 KVA . | 4 | Each Set | |
107 | 82 | Supply and fixing in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enammaled white letters figures and conventional skulls and bones in signal red colour fixed with mild steel clamps, bolts, nuts of approved size for HT 25X 20 cm size complete all as specified and as directed. | 15 | Each | |
108 | 83 | Supply and fixing in replacement danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed. | 25 | Each | |
109 | 84 | Supply and fixing in replacement of outdoor waterproof LED glow sign board of dimension 8x4 ft for outdoor installation having aluminium composite panel of 3 mm thickness base with box type frame having complete LED letters fixed on the base of the board with complete heavy duty driver set for LED letters including angle iron of size 40x40x5 mm of suitable length for holding the whole assembly complete all as specified and as directed.\n Note:- The content of the board will be finalised by Engr in charge. | 2 | Each Job | |
110 | 85 | S&F in replacement of MCCB 3 pole, capacity 100 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand | 2 | Each | |
111 | 86 | S&F in replacement of MCCB 3 pole, capacity 125 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand | 2 | Each | |
112 | 87 | S&F in replacement of MCCB 3 pole, capacity 160 Amps with breaking capacity 36 KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand. | 3 | Each | |
113 | 88 | S&F in replacement of MCCB 3 pole,capacity 250 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand. | 3 | Each | |
114 | 89 | S&F in replacement of MCCB 3 pole, capacity 350 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixe complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand. | 2 | Each | |
115 | 90 | S&F in replacement of MCCB 3 pole, capacity 400 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixe complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand. | 1 | Each | |
116 | 91 | Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed. | 2 | Each Job | |
117 | 92 | S&F out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3.15mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Copper Bus -bar three phase 4 wire system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- .Make:- Conelec Systems/Tricolite/Mc Layer/universal | 1 | Each Job | |
118 | 92.01 | INCOMING\n(i) MCCB 315A, 4 pole, 36KA, Overload setting adjustable and short circuit setting fixed -01 No \n(ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor- 1 No \n(iii) Phase indicator lamp (LED type) 1 ste (set of three) OUT GOING\n(i) MCCB 125A, 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 01 Nos (ii) MCCB 100A, 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 02 Nos (iii) MCCB 63A, 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 03 Nos | |||
119 | 93 | S&F out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3.15mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Copper Bus -bar three phase 4 wire system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- .Make:- Conelec Systems/Tricolite/Mc Layer/universal | 1 | Each Job | |
120 | 93.01 | INCOMING\n(i) MCCB 315A, 4 pole, 36KA, Overload setting adjustable and short circuit setting fixed -01 No \n(ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor- 1 No \n(iii) Phase indicator lamp (LED type) 1 ste (set of three) OUT GOING\n(i) MCCB 125A 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 01 Nos (ii) MCCB 100 A 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 02 Nos (iii) MCCB 63A 4 pole, 16 KA Overload setting adjustable and short circuit setting fixed - 03 Nos | |||
121 | 94 | S&F On /off load Change over switch with sheet enclosure type 200 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed. | 1 | Each | |
122 | 95 | S&F On /off load Change over switch with sheet enclosure type 400 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed. | 1 | Each | |
123 | 96 | S&F On /off load Change over switch with sheet enclosure type 630 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed. | 1 | Each | |
124 | 97 | S&F On /off load Change over switch with sheet enclosure type 1000 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed. | 1 | Each | |
125 | 98 | Labour only for trimming of overgrown branches by the use of hand held mechanical saw or machete whichever suitable upto a girth not less than 10mm in dia and not more than 40mm in dia complete without felling of trunk to render free the disturbance created by the outgrouth in power distribution network comparising of transformer/panels outdoor, poles, cables, high mast light and illumination hindrance of security lights complete all as specified and directed by Engr-in-Chagre. | 185 | Each Job |