| 1 | 1 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :\r\nAll kinds of soil\r\n | 1 | 54 | cum |
|---|
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.\r\nOrdinary rock\r\n | 2 | 54 | cum |
|---|
| 3 | 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.\r\nAll kinds of soil.\r\n | 3 | 15.8 | cum |
|---|
| 4 | 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :\r\n1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)\r\n | 4 | 0.98 | cum |
|---|
| 5 | 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :\r\n1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)\r\n | 5 | 3.62 | cum |
|---|
| 6 | 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :\r\n1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)\r\n | 6 | 9 | cum |
|---|
| 7 | 7 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :\r\nCement mortar 1:6 (1 cement : 6 coarse sand)\r\n | 7 | 25.92 | cum |
|---|
| 8 | 8 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).\r\nSal wood\r\n | 8 | 1.54 | cum |
|---|
| 9 | 9 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).\r\nKiln seasoned and chemically treated hollock wood\r\n | 9 | 0.56 | cum |
|---|
| 10 | 10 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.\r\nKiln seasoned selected planks of sheesham wood\r\n35 mm thick\r\n | 10 | 6.48 | sqm |
|---|
| 11 | 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :\r\n250x16 mm\r\n | 11 | 4 | each |
|---|
| 12 | 12 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :\r\n150x10 mm\r\n | 12 | 24 | each |
|---|
| 13 | 13 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :\r\n100 mm\r\n | 13 | 24 | each |
|---|
| 14 | 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.\r\nElectric resistance or induction butt welded tubes\r\n | 14 | 1599.6 | kg |
|---|
| 15 | 15 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.\r\n0.63 mm thick with zinc coating not less than 275 gm/m²\r\n | 15 | 18 | metre |
|---|
| 16 | 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.\r\n | 16 | 186.72 | sqm |
|---|
| 17 | 17 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :\r\nRidges plain (500 - 600mm)\r\n | 17 | 15.8 | metre |
|---|
| 18 | 18 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :\r\n1:4 (1 cement: 4 fine sand)\r\n | 18 | 14.04 | sqm |
|---|
| 19 | 19 | Finishing walls with water proofing cement paint of required shade :\r\nNew work (Two or more coats applied @ 3.84 kg/10 sqm)\r\n | 19 | 14.04 | sqm |
|---|
| 20 | 20 | Applying priming coat:\r\nWith ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)\r\n | 20 | 19.44 | sqm |
|---|
| 21 | 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :\r\nTwo or more coats on new work\r\n | 21 | 19.44 | sqm |
|---|
| 22 | 22 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :\r\nFor fixed portion\r\nPowder coated aluminium (minimum thickness of powder coating 50 micron)\r\n | 22 | 458.54 | kg |
|---|
| 23 | 23 | P/F wooden plank 20 mm thick in wall panells i/c all complete\r\n | 23 | 157.297 | sqm |
|---|
| 24 | 24 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.\r\nGroup C\r\n | 24 | 12 | Point |
|---|
| 25 | 25 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.\r\n | 25 | 24 | Metre |
|---|
| 26 | 26 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required\r\n2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire\r\n | 26 | 50 | Metre |
|---|
| 27 | 27 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.\r\n3 pin 5/6 amp socket outlet\r\n | 27 | 6 | Each |
|---|
| 28 | 28 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).\r\n | 28 | 4 | Each |
|---|
| 29 | 29 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\r\n2 + 8 way/ 10 way , Double door\r\n | 29 | 2 | Each |
|---|
| 30 | 30 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\r\nSingle pole\r\n | 30 | 2 | Each |
|---|
| 31 | 31 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.\r\n40 amps\r\n | 31 | 2 | Each |
|---|
| 32 | 32 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.\r\n | 32 | 24 | Metre |
|---|
| 33 | 33 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.\r\n | 33 | 2 | Each |
|---|
| 34 | 34 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)\r\n | 34 | 18.02 | Metre |
|---|
| 35 | 35 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.\r\nUpto 35 sq. mm\r\n | 35 | 29.04 | Metre |
|---|
| 36 | 36 | SITC of prewired florocent lamp with tube and fitting 40 watt philips etc.\r\n | 36 | 6 | Each |
|---|
| 37 | 37 | Supplying and fixing and Installation PL lamp 11 watts philips all approved and direction of Engineer-in-Charge | | 4 | each |
|---|
| 38 | 38 | Cost Index @61.9% | 37 | 908483 | Nos |
|---|