Rail India Technical And Econimics Services Ltd-RITES has published Design , Supply , Installation And Commissioning Of All The In-Door And Outdoor Signaling And Telecommunication Works , And Other Allied Works At Delhi Kishanganj Of Delhi Division In Northern Railway. Submission Date for this Tender is 20-04-2021. Railway Signaling Systems Tenders in Gurgaon Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Apr-2021 | Corrigendam1 | Technical Bid | 20-04-2021 |
2 | 16-Apr-2021 | Corrigendum 2 | Technical Bid | 20-04-2021 |
Name of Work:Design, Supply, Installation and commissioning of all the In-door and Outdoor Signaling & Telecommunication works, and other allied works at Delhi Kishanganj of Delhi Division in Northern Railway | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | INDOOR SUPPLY | ITEM 1 | ||
2 | 2 | Supply of Electronic Interlocking (Hot Standby) with dual VDU of 55" with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan and to suit the signalling plan of stations.Scope of supply against this item includes all the indoor equipments necessary for successful functioning of Central EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications .\n1. Microprocessor equipment.\n2. I/O cards with card cage and motherboard.\n3. Power supply cards.\n4. All types of connectors and couplers as required.\n5. Industrial grade Dual VDU of 55" .\n6. Industrial grade PC & monitor of 40"\n7. maintenance VDU of 40" console with Laser printer at panel building.\n8. All types of relays required for interfacing.\n9. ECRs suitable for LED signal lamps.\n10. DC-DC convertors (input voltage 110 V DC and output voltage as required)\n11. All types of indoor wires as required.\n12. All types of indoor terminals and fuses as required except \n terminals for main CTR.\n\n | ITEM 2 | ||
3 | 3 | 13. Racks for mounting EI equipments and interfacing relays.\n14. Termination rack for indoor cables.\n15. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.\n16. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. \n17. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. \n18. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three sets. \n19. Ring Earthing and EMI shielding of EI room.\n20. Any other item contractor feels neccessary as per their sysyem.\n21.Completion plan of stations.\n22. Class 'A' type surge protection device protection at each SSI room/goomty, mounting arrangements and accessories necessary to make the EI system functional. \n23. Work place for EI is also provided by the contactor\n | ITEM 3 | ||
4 | 4 | Note:\n1. Supply of Optic Fibre Cable, 60Cx1mm indoor cable, IPS, 24 V point operating relays(QBCA1), KLCR, Main Cable Termination Rack & terminals for Outdoor cables and relay rack for mounting point relays are not included in this item. 2. All the materials, submitted by the bidder as above and are neccessary for successful commissioning of system, shall be supplied by the contractor without any extra cost. Variation in Bits and variation in number of routes upto (+) 10% shall have no cost bearing.\n3. For further variation (above 10%) of routes, cost will be recovered on prorata basis for % of routes increased. | ITEM 4 | ||
5 | 5 | Delhi Kishan Ganj | ITEM 5 | 1 | System |
6 | 6 | Spares of O&M | ITEM 6 | ||
7 | 7 | Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. | ITEM 7 | 1 | Lot |
8 | 8 | Delhi Kishan Ganj | ITEM 8 | ||
9 | 9 | Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded as per specifications mentioned in TS. | ITEM 9 | 1 | No. |
10 | 10 | Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI. * Above items includes suitable cabinet for storing tools to ensure longer life. | ITEM 10 | 1 | Set |
11 | 11 | Supply of Hard & soft copy (6 copies as built ) of following indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: this includes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .The also includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testing copy & 2 copies as costruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIP's and other Misc Drgs as per concerened Rly practice and get its approval from railways,if requiered- \n(i) Signalling Interlocking Plan (as per Rly practice)\n(ii) Selection table, \n(iii) Vital & non-vital I/O Bit Chart, \n(iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. \n(v) Front plate diagram of control/indication panel. \n(vi) Application logic \n(vii) Interface circuit with contact analysis. \n(viii) Equivalent circuit of application logic. \n(ix) Prepration & supply of SWRD (station Working Rule Diagram). \n(x) Prepration & supply of station working Rule. | ITEM 11 | 1 | Job |
12 | 12 | Relay Rack assembly complete with fixtures for mounting point group relays/'Q' style relays in Relay or EI Hut with all accessories like scaffolding, ladder, runway for indoor cables/wires alongwith mounting arrangement as per drg. No. NR/S&T/project/14/2015. | ITEM 12 | 1 | No |
13 | 13 | Main cable termination rack complete assembly with hylam sheet , screws, nuts & bolts, scaffolding ladders for cable wires alongwith mounting arrangements etc. as per Drg No.NR/S&T/project/13/2015. | ITEM 13 | 1 | No |
14 | 14 | Fuse block made of PBT as per Specn.No. IRS-S-75/2006(Rev.2) and Drg.No. SA-23748 (Alt. 4) or latest amendment. Fuse block shall be suitable for round head type voltage fuses rating:2A/4A/16A. | ITEM 14 | 1 | No |
15 | 15 | Non deteriorating type fuses as per IRS-S-78/92 with latest amendment. Rating 2Amps-65%, 4Amps-25%, 16Amps-10%, round head type voltage fuses rating:2A/4A/16A. | ITEM 15 | 1 | No |
16 | 16 | Design, Fabication, Supply, Installation, wiring, testing & commissioning of fuse alarm system of various type of fuses with automatic change over system along with audio visual indication. Per Module configuration to be decided by Engineer Incharge as per site requirement. To be supplied & installed as per RDSO spec. no.RDSO/SPN/209/2012 Rev.1 or latest (Per unit is Per Module) | ITEM 16 | 1 | No |
17 | 17 | Supply & fixing of PPTC fuses 2/6A. | ITEM 17 | 1 | No |
18 | 18 | ARA terminal (1 way) made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5). | ITEM 18 | 1 | No. |
19 | 19 | Supply of 2conductor disconnect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Ver.2.0 or latest. | ITEM 19 | 1 | No. |
20 | 20 | Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest.\n | ITEM 20 | 1 | No. |
21 | 21 | Supply of Steel carrier Rail 35x7.5mm/0.039in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/ 2004 Ver.2.0 or latest. | ITEM 21 | 1 | No. |
22 | 22 | Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest. | ITEM 22 | 1 | No. |
23 | 23 | SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012, (Ver 3.0) with latest ammendment alongwith LMLA Battery Bank of 200AH & Battery rack (Configuration based on RDSO dwg. no. SDO/IPS/PI-4L/RE/002 and site specific load requirement, shall be put up to RITES with load calulation sheet shall be approved by employer/consultant before supply) | ITEM 23 | 1 | No. |
24 | 24 | DG set 15 KVA, 230 V AC single phase with only Mahindra or Kirlosker or Cummins or crompton or similar quality alternator make , two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 15KVA to IRS-S-69/86 along with sound proof enclosure for DG set as per latest guidelines of Central pollution control board of india. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set for self starting and Iron clad siemens or sony single phase (2 way ON-OFF-ON) changeover switch 63 Apms). Suitable Battery cahrger for charging this battery c) 60 liter diesel tank | ITEM 24 | 1 | No. |
25 | 25 | DG set 35 KVA, 230 V AC single phase with only Mahindra or Kirlosker or Cummins or crompton or similar quality alternator make , two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 20KVA to IRS-S-69/86 along with sound proof enclosure for DG set as per latest guidelines of Central pollution control board of india. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set for self starting and Iron clad siemens or sony single phase (2 way ON-OFF-ON) changeover switch 63 Apms). Suitable Battery cahrger for charging this battery c) 60 liter diesel tank\nSupply of single phase diesel generator set 240V/35KVA diesel engine manual control panel air cool and exciter panel\nand push button assembly as per Spec. No. IRS 69/86 or latest fitted with self start and staff facility as per IS/BS specs.\nAlong with sound proof enclosure for DG set as per latest uidelines and control board of India battery charger & battery of 12V, 120 AH of Standard/exide/UB-Mar/Amco make for self starting and iron clad Siemens or Sony make single phase (2way ON-OFF) change over switch 63Amps. | ITEM 25 | ||
26 | 26 | Supply of Automatic change-over unit for change-over between three power supply sources of 63 A/230 volts, single phase with provision of manual bypass arrangement. Drawing shall be got approved by Engineer Incharge. | ITEM 26 | 1 | No. |
27 | 27 | Supply & installation of maintenance free single earthing for IPS/DAC Equipment. All the materials required shall be supplied by the contractor including cadmium bronze wire rope for connection between earth electrode and equipment box). | ITEM 27 | 1 | Set |
28 | 28 | Supply and installation of Earth leakage Detector for monitoring different AC and DC supplies including all accessories as per Spn RDSO/SPN/256/2002 or latest and stipulations of tender doccuments (ELD having 12 channel type). | ITEM 28 | 1 | NO |
29 | 29 | Supply & installation of Data logger with interfacing capability with SSI's to moniter Analog & digital inputs(Minimum 24 analog & 1024 digital inputs) & enable for networking for a central place as per speci.no. IRS:S-99/2006 ( amd-3) with latest amendments. Required type of modem and SSI protocol converter is also to be supplied. | ITEM 29 | 1 | No |
30 | 30 | Supply of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. | ITEM 30 | 1 | No. |
31 | 31 | Wooden block counter of size 700 mm x 700 mm W x 900 mm H made of teakwood frame & 10 mm /20 mm thick water proof ply with formica finish on top and all four sides having two compartment inside & two doors on opposite sides. | ITEM 31 | 1 | No. |
32 | 32 | Office Chair of continuous arms having cushened seats and rest T.W. Arm rest size 36" x 21" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled "Indian Make". Godrej/Jalaram Make. | ITEM 32 | 1 | Nos. |
33 | 33 | Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys. Olive green colour Godrej Make. | ITEM 33 | 1 | Nos. |
34 | 34 | Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, Godrej Make. | ITEM 34 | 1 | Nos. |
35 | 35 | Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black.The chair has plastic caned seat and back on 25 mmround tubular frame. The base is of pressedsheet metal. Godrej/ Allwyn/ Chandan/ Khira make.Width 700 mm,Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, Colour Grey. | ITEM 35 | 1 | Nos. |
36 | 36 | 4 door book case of size 1675x840x308mm Godrej make | ITEM 36 | 1 | Nos. |
37 | 37 | Desk type electronic Magento phones as per Spec. No. IRS(S)TC-79/2000 with latest amendments. | ITEM 37 | 1 | Nos. |
38 | 38 | Supply & fixing of Fire Extinguisher CO2 Type (capacity 5 Kg) | ITEM 38 | 1 | No. |
39 | 39 | OUTDOOR SUPPLY | ITEM 39 | ||
40 | 40 | Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDGH | ITEM 40 | 1 | Nos. |
41 | 41 | Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDFH. | ITEM 41 | 1 | Nos. |
42 | 42 | Supply of Relay,Non AC immune ,plug in type,style QN1,DC neutral line relay,24 V DC 8F/8B contacts, front & back contacts metal to carbon with plug board retaining clip & connectors confirming to BRS:931A,IRS:S@ 45<47N44@IRS:S-45/47/68 & IRS:S-23/88 as applicable.The interlocking\ncode for this unit shall be ABCDF or latest | ITEM 42 | 1 | Nos. |
43 | 43 | Supply of Key Lock Relay, type TMA 24V DC with 2F/2B contacts cofiguration with different wards combination as per latest RDSO specification. Details of ward combination will be provided during execution of work. \n | ITEM 43 | 1 | No. |
44 | 44 | PVC Insulated Armoured un-screened, under- ground Railway Signaling copper conductor cable confirming to RDSO Specification no. IRSS- 63/2014 with amendment -4 or latest | ITEM 44 | ||
45 | 45 | a) 2 core x 2.5 sq.mm. | ITEM 45 | 1 | Km |
46 | 46 | b) 6 core x 1.5 sq.mm. | ITEM 46 | 1 | Km |
47 | 47 | c) 12 core x 1.5 sq.mm. | ITEM 47 | 1 | Km |
48 | 48 | PVC insulated armoured, Unscreened, Underground Power cable, 2x25 sq. mm. Stranded Aluminium conductor confirming to RDSO specification IRS:S-63/2007 with latest amendment and IS 1554 (part-1) | ITEM 48 | 1 | Km |
49 | 49 | Supply of XLPE Insulated,Single later of Galvanised Steel Strips Armoured un-screened, under- ground Railway power cable having Aluminium conductor confirming to RDSO Specification no. IRS-S-63/2014 with amendment -4 or latest and IS-7098(P-1) latest of size 2c x 70 sq.mm in drum length of 1000 mtrs with +-5% tolerance. | ITEM 49 | 1 | Km |
50 | 50 | Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/2005 (Ver. 1) Amndt 1 to 5 or latest amendment having 0.9mm dia. | ITEM 50 | 1 | Km. |
51 | 51 | Armoured Optical Fibre cable 24 Fibers as per RDSO specification No. IRS:TC:55-2006 rev. 1 with Amdt. 1.1 | ITEM 51 | 1 | Km |
52 | 52 | Cable unarmoured PVC insulated, unseathed with plain annealed high conductivity 650V grade copper conductor as per colour coding scheme of Raliways in 100 meter coils, confirming to RDSO Specification No: IRS-S-76/89 with latest amendment- | ITEM 52 | ||
53 | 53 | i) 16 x 0.2 mm.(Grey) | ITEM 53 | 1 | 100 mtr. Coil |
54 | 54 | ii) 3 x 0.75 mm. (Red, Green & Black) | ITEM 54 | 1 | 100 mtr. Coil |
55 | 55 | iii) 1x6 sq mm. (multistrand flexible wire) | ITEM 55 | 1 | 100 mtr. Coil |
56 | 56 | iv) 1x10 sq mm. (multistrand flexible wire) | ITEM 56 | 1 | 100 mtr. Coil |
57 | 57 | v) Supply of Power wire as per IRS specification No.S-76/89 (Amndt.2) or latest with latest amendments (1x16 sq mm, Red & Black colour) | ITEM 57 | 1 | KM |
58 | 58 | Supply of Wiring materials as per IRS Spec no IRS-76/89 with amendment no 2 or latest duly inspected by RDSO, Copper Wire, PVC sheathed and PVC inulation of size 60 x 1 Sq mm | ITEM 58 | 1 | km |
59 | 59 | Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight through as RDSO specn. No.IRS: TC 77/2012 (Rev.3.0) with (Amdt.-1 to 3) or latest. | ITEM 59 | 1 | Nos. |
60 | 60 | Supply of HDPE telecom duct with outer diameter of 40 and inner diameter of 33 mm permanently lubricated as per Specification no. RDSO/SPN/TC/45/2013, Rev.-2.0 Amdt.-1.0 & 2.0 or TEC GR No.G/CDS 08/02 Nov.2004 with latest amendment as available or latest. HDPE pipe shall be supplied For each Km. of HDPE duct following items are to be supplied alongwith 4 mm dia polypropylene rope of approved quality inside whether required. For each Km. of HDPE duct following items are to be supplied a) End plugs-2 No.b) Cable sealing plugs - 2 Nos.C) Plastic couplers slip fit/push fit type-2 No.d) End plugs to be provided along with drum - 2 No. | ITEM 60 | 1 | Km. |
61 | 61 | Supply of Half split double wall corrugated (DWC) pipe of HDPE in 2/3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement. | ITEM 61 | ||
62 | 62 | a) Size : 120 mm outer dia. and 103 mm inner dia. | ITEM 62 | 1 | Mtrs. |
63 | 63 | b) Size : 200 mm outer dia. and 175 mm inner dia. | ITEM 63 | 1 | Mtrs. |
64 | 64 | Non-Split HDPE DWC pipe Confirming to IS:14930 part-II, with threaded coupler, of following sizes: | ITEM 64 | ||
65 | 65 | a) Size 120mm outer dia and 103 mm inner dia | ITEM 65 | 1 | Mtrs. |
66 | 66 | b) Size 200mm outer dia and 175 mm inner dia | ITEM 66 | 1 | Mtrs. |
67 | 67 | Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm after laying of cable & refilling the trench by loose soil of 100mm to over cable. | ITEM 67 | 1 | No. |
68 | 68 | Galvanised Iron pipe 100 mm dia `B' class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes) | ITEM 68 | 1 | Mtrs. |
69 | 69 | Fabrication, supply and fixing of cable marker of 1:3:6 concrete as per No.NR/S&T/CON/1.5/97A. The marker shall be fixed at various places of cable route as per instructions of Engr. at site | ITEM 69 | 1 | No |
70 | 70 | Colour light signal (2 aspect) complete set as per drg.No.SA - 23003 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items : | ITEM 70 | 1 | Set |
71 | 71 | a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81. | ITEM 71 | ||
72 | 72 | b) Signal base Cast Iron 140 mm dia. to drg. No. S-2011/M. | ITEM 72 | ||
73 | 73 | c) CLS ladder complete with platform and base 4.5 mtrs.long to drg.No.SA-23153(Adv.) Alt 1. | ITEM 73 | ||
74 | 74 | d) Colour Light Signal Unit 2 Aspect complete with out signal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64. | ITEM 74 | ||
75 | 75 | e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 | ITEM 75 | ||
76 | 76 | Colour light signal (3 aspect) complete set as per drg.No.SA23002 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items : | ITEM 76 | 1 | set |
77 | 77 | a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81. | ITEM 77 | ||
78 | 78 | b) Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M. | ITEM 78 | ||
79 | 79 | c) CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1. | ITEM 79 | ||
80 | 80 | d) Colour Light Signal Unit 3 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23002 A/M (Adv.) alt.9 & Specn. IRS-S-26/64. | ITEM 80 | ||
81 | 81 | e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment. | ITEM 81 | ||
82 | 82 | Colour light signal (4 aspect) complete set as per drg.No.SA23001 A/M (adv.) alt.9 & Specn. IRS-S-26/64 consisting of the following items : | ITEM 82 | 1 | Set |
83 | 83 | a) Supply of CLS post 140mm dia. 4.5 M long to specification IRS.S.6.81or latest (as per site requirement). | ITEM 83 | ||
84 | 84 | b) Supply of Surface base 140mm dia.post to suit CLS as per drg.S.2011/M | ITEM 84 | ||
85 | 85 | c) Supply of CLS ladder set complete with staging, supports, signal number plate, cast iron ladder base to suit 4.5 Metre post as per drg.no.SA. 23153.S.2033. | ITEM 85 | ||
86 | 86 | d) Colour Light Signal Unit 4 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23001 A/M (Adv.) alt.9 & Specn. IRS-S-26/64. | ITEM 86 | ||
87 | 87 | e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment. | ITEM 87 | ||
88 | 88 | Supply of Junction type/Directional type route indicator 1 way to drawing no.SA.23401 with IRS - S 66/84 with amendment-1 or latest | ITEM 88 | 1 | Nos. |
89 | 89 | Junction type route indicator 2 way complete without lenses, lamp holders and lamps. to IRS-S-66/84 , amdt.1 ot latest with RDSO drg.No.SA-23402 (Adv.) or latest. | ITEM 89 | 1 | No |
90 | 90 | Supply & installation of universal AC/ DC numeric route indicator for 1-19 routes with left & right arm complete with optical sensor, housing w/o mounting pole for use with LED ECR. | ITEM 90 | 1 | No |
91 | 91 | OFF set bracket for Colour light signal 140mm outside dia. post with 'U' bolt and nuts as per drg No: SA-23080 (adv.) alt. 1. | ITEM 91 | 1 | No |
92 | 92 | Independent shunt signal complete having following items. | ITEM 92 | 1 | set |
93 | 93 | a) Shunt signal post 90 mm dia 1m long to IRS-S-6/81. | ITEM 93 | ||
94 | 94 | b) Shunt signal surface base 90 mm dia drg.No. S-2011. | ITEM 94 | ||
95 | 95 | c) Position light shunt signal unit without lamp holder unit, lenses & lamps to RDSO drg.No.SA-23840(adv.) ALT-2. | ITEM 95 | ||
96 | 96 | d) 04 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M. | ITEM 96 | ||
97 | 97 | Shunt signal dependent type drg No. SA-23840 (adv.) Alt.-1 and S-23845 (adv.) with offset bracket 3½'' dia. to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders. | ITEM 97 | 1 | set |
98 | 98 | Calling on signal unit position light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64. | ITEM 98 | 1 | No |
99 | 99 | LED signal lighting unit for Junction Type route indicator conforming to Indian Raiway chromaticallity standards & RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM 99 | 1 | No |
100 | 100 | LED signal lighting unit for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM 100 | 1 | No |
101 | 101 | Supply of LED Signal Lighting Unit for Main Signals as per RDSO specification No. RDSO/SPN/199/2010 (Rev 1.1) ) or latest | ITEM 101 | ||
102 | 102 | a) For Red aspect | ITEM 102 | 1 | No |
103 | 103 | b) For Yellow aspect | ITEM 103 | 1 | No |
104 | 104 | c) For Green aspect | ITEM 104 | 1 | No |
105 | 105 | LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM 105 | 1 | No |
106 | 106 | TRACK Circuit | ITEM 106 | ||
107 | 107 | Track feed battery charger 110 V AC / 2 - 6 V DC - 10 amp charging rate suitable to charge 1, 2 or 3 cells of 80 AH, to IRS-S-89/93 Amendment-2 or latest. | ITEM 107 | 1 | No |
108 | 108 | Track feed variable resistance (with phenolic moulded base) 30ohms to suit RDSO drawing number SA20166/M/adv Alt-1, IRS: S-23. | ITEM 108 | 1 | No |
109 | 109 | `B' type choke as per specification No.IRS-S-65/83 Amndt -1 or latest. | ITEM 109 | 1 | No. |
110 | 110 | Fibre glass Track Lead Junction Boxes as per IRS(s)Drg. No.SA-20/01/M made of FRP complete with one way terminal block and 450 mm long, 25mm dia plastic HDPE pipe. termination of signalling cable for the use of track circuit. | ITEM 110 | 1 | No. |
111 | 111 | Low Maintenance secondary cell of 80AH. Confirming to RDSO Spec. No. IRS:S88/2004 (A) Amndt.-1 or latest. | ITEM 111 | 1 | No |
112 | 112 | Channel Bond pin single groove.Tnned or Zinc coated 7mm dia. As per RDSO specn. No. IRS:S-17/75 with Ammendment 1 for bonding track ckt. Wires. | ITEM 112 | 1 | No. |
113 | 113 | G.I.Bond wire soft 8 SWG for bonding resistance -132 ohm/Km. at 27 deg.C. to IS-279 | ITEM 113 | 1 | Kg. |
114 | 114 | Nylon Insulated rail joint complete as per specn.IRS-S-40/84 and RDSO's Drg.No SA-22101 (alt-6) for 52 kg rails /SA-22171 (alt-2) for 60 Kg rails/ SA-22191 (alt-2) for 90R rails comprising of :\na) Channel side plate LH -2 No.\nb) Channel side plate RH -2 No.\nc) End post - 1 No.\nd) Insulating plate. - 4 No.\ne) Bushes - 8 No.\nf) Long fish bolts. - 4 No. | ITEM 114 | 1 | No. |
115 | 115 | Relay, AC immune, plug-in type, style ‘QTA2’, neutral track, 9 ohms, 2F.1B contacts, front and back contact metal to carbon, complete with plug board, retaining clips and connectors confirming to BRS-939A, BRS-966 (Appendix F2), IRS-S-34 & IRS-S-23 (as applicable). | ITEM 115 | 1 | No. |
116 | 116 | Supply and fixing of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. | ITEM 116 | 1 | No. |
117 | 117 | Relay AC immune , Plug in type Style QSPA1 Neutral Line Slow to pickup, 24V DC 8F,4B contacts Front and back contactsMetal to Carbon complete with plug board retaining clips and connectors conforming to BRS:933A,IRS-S60 &IRS S23 (as applicable). The interlocking code for this unit shall be ABDEJ | ITEM 117 | 1 | No. |
118 | 118 | Relay AC immune, plug in type style QBCA1, DC based point contactor, 24V DC, 2F (HD) 4B contacts, front contacts heavy duty and back contacts metal to carbon complete with plug board, retaning clip and connectors confirming to BRS943, IRS S-34 & IRS S-23 interlocking code BCESK. | ITEM 118 | 1 | No. |
119 | 119 | Relay, AC Immune, plug-in type, Style "QNA1K" 24 V/1000 Ohm | ITEM 119 | 1 | No. |
120 | 120 | Supply of Electronic Timer Relay, 24 V DC, 60/120 sec. | ITEM 120 | 1 | No. |
121 | 121 | Axle counter | ITEM 121 | ||
122 | 122 | Designing as per SIP & Supply of Multi Section Digital Axle Counter System (MSDAC) complete system as per RDSO Specification No .RDSO/SPN/176/2013 (Version 3 ) or latest consisting of:-\n1) Central evaluator Unit\n2) SM’s Reset Panel\n3) Field unit along with web detector\n4) Centralised High Voltage DC-DC convertors\n5) Final track clearance relay for each section along with accessories equipped for detection points and track section. | ITEM 122 | 1 | DP |
123 | 123 | Tool Kit of MSDAC consisting of the following:-\n1) Portable Data Analyser with Data Analysis software for report\ngeneration & Analysis-1 No.\n2) Pure Sine wave Digital Multimeter Kusam – MECO Make Model\nNo.859CF or equivalent – 1 No.\n3) Dummy Wheel CEL makes – 1No.\n4) Ring Spanner 17-19, 24-26 – 1 No. each\n5) Open end Spanner 17-19, 24-26- 1 No. each\n6) Socket Spanner with handle – 1 no.\n7) Screw Driver No.902 – 1 No.\n8) Screw Drive No.935 – 1 No.\n9) Torque Wrench – 1 No.\n10) Marking jig for drilling – 1 No.\n11) Monitoring Unit- 1No | ITEM 123 | 1 | No |
124 | 124 | Electrical point machine, IRS heavy duty non-trailable rotary locking type 143mm throw to operate on 110V DC complete with lock & detector slides and cable termination box as per IRS:S-24/2002 (Amd 1) & IRS-S-37/82 (Amd 3 or latest), Drg. No. S-10910 for motor Assembly Drg. No. S-10800. (One No. tool kit will be supplied for installaton for a group of 08 Nos of point machine) including ground connection as per latest drg. & IRS specification. | ITEM 124 | 1 | No |
125 | 125 | Insulation for gauge tie plate for BG as per IRS-S-40/84 and drg.No.T-10372, T-10368, T-10371 each set comprising of :\na) Insulating plate - 2 No.\nb) Bushes - 6 No.\nc) Washers - 12 No. | ITEM 125 | 1 | set |
126 | 126 | Insulation for following & leading P-way stretcher bar for BG as per IRS-S-40/84 & drg.no.10367 10368 & 10371 each set comprising of :\na) Insulating plate - 2 No.\nb) Bushes - 2 No.\nc) Washers - 4 Nos.\n | ITEM 126 | 1 | set |
127 | 127 | Insulation for 'P' bracket for point machine as per Rly. design each set comprising of :\na) Channel side plate LH -2 No.\nb) Channel side plate RH -2 No.\nc) Bushes - 4 No.\nd) Washers - 4 No. | ITEM 127 | 1 | set |
128 | 128 | Single apparatus case Full steel RE with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/219/82 & 221/82 with Alt.B. | ITEM 128 | 1 | No. |
129 | 129 | Apparatus case Half steel RE half with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/220/82 & 221/82 with Alt.B. | ITEM 129 | 1 | No. |
130 | 130 | Key Lock 'E' type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different wards. | ITEM 130 | 1 | No. |
131 | 131 | Design, prepearation & supply of Six (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5 microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES) | ITEM 131 | 1 | station |
132 | 132 | i) Cable route plan | ITEM 132 | ||
133 | 133 | ii) Location box details with location wiring diagram | ITEM 133 | ||
134 | 134 | iii) Cable termination details | ITEM 134 | ||
135 | 135 | iv)Cable corage plan | ITEM 135 | ||
136 | 136 | v) C.T. Rack details | ITEM 136 | ||
137 | 137 | vi) Track bonding plan | ITEM 137 | ||
138 | 138 | vii) Cable jointing details | ITEM 138 | ||
139 | 139 | viii) Signal lighting circuit | ITEM 139 | ||
140 | 140 | ix) Circuit diagram for LC Gate No. | ITEM 140 | ||
141 | 141 | x) Gate Working Rule with Gate Signal Diagram | ITEM 141 | ||
142 | 142 | Supply of SLB/BSLB/SB/GWB/C-on Board as per RDSO Drg No SA-2373 with latest amendment, Casting, concreting and curing of foundation & erection SLB/BSLB/SB as per Drg No.NR/S&T/CON/7.4/97 has to be done by contractor. | ITEM 142 | 1 | No |
143 | 143 | Various types of markers as | ITEM 143 | ||
144 | 144 | Supply of hand cuff (universal) locks with key (one key for every 4 locks). | ITEM 144 | 1 | No |
145 | 145 | Supply of Jumper PVC insulated Jumper (Lead wire) 7 strand\n | ITEM 145 | 1 | MTRS |
146 | 146 | Supply, Installation, Testing, Commissioning and Integration of the complete System of Microprocessor Based Networkble Analogue Addressable up to 64 nodes 1 Loop Fire Alaram control Panel With Minimum 320 Character LCD Display the panel should be equipped with sufficient nos. of loop. (As per RDSO Specification No. RDSO SPN217/2016 ver 1.0 or latest). Supply of 06 multi detector, 01 Hooter & Strobe, 01 Analogue Addressable Manual Call Point With infegal short circult isolator, analogue addressable protocol having status LED for alarming & standby mode. Electronically addressed, 01 FRLS armoured cables & power with all accessories for connection of all Fire alarm devices. | ITEM 146 | 1 | NOS |
147 | 147 | Supply and Installation of Demineralizer plant of aquaguard make or similar capacity 65 Litres per hour approx. This includes all thepipe connections from water source to unit and also to collection unit. | ITEM 147 | 1 | NOS |
148 | 148 | Supply & installation of Annunciator (Multiway telephone exchange) 10 lines as per RDSO Drg no. TCA-3352 (Adv.) or latest. | ITEM 148 | 1 | Nos |
149 | 149 | Spare Booms for Electric Lifting Barrier as per RDSO Drg No RDSO/S-11600 or latest & RDSO specification no RDSO/SPN/208/2012 ver.2.0 or latest. | ITEM 149 | ||
150 | 150 | Supply of emergency sliding boom complete with all accessories for L/B gate. | ITEM 150 | ||
151 | 151 | Supply, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1" wooden batton fitted all around onthe rear as per instruction of Engineer at site. All the materials to be supplied by contractor. | ITEM 151 | 1 | Nos |
152 | 152 | Supply & laying of anti-static PVC flooring with adhesive ( 2.00 mm thickness) in Relay room/equipment room/Data logger room/Axle counter room as per instruction of Engineer at site. | ITEM 152 | 1 | sq.mt |
153 | 153 | Provision of screen on signal when they fall with in two meter from live conductor by expanding Metal size 20mm X 60mm (strand 3.25 mm wide and 1.6 mm thick) as per instruction at site by Engineer incharge .This includes supply of all materials including earth electrode and earthing arrangement. | ITEM 153 | ||
154 | 154 | Supply of Hydrometer of reputed make for measuring specific gravity of the battery graded acid with mounting stand in battery room /location boxes.\n | ITEM 154 | 1 | NOS |
155 | 155 | Supply of cable fault locator for underground cable as per model no. Telscout TS-90 (Test signal output1/2 Sine, Pulse width 5nsec to 2500nsec, Max Range:1500m, Filter cut-off Frequency:150kHz(High Pass Filter), Gain:0 to 63dB), Stanley or similar branded make as per specification. | ITEM 155 | ||
156 | 156 | Supply of Digital insulation Tester (Megger) 100 V,Motwani, Philips or equal to make. Inspection. | ITEM 156 | 1 | NOS |
157 | 157 | Supply & installation of 30/40 lines JB with prov. of terminals and board 6mm thick hylum sheet to be supplied by contractor including terminals (to suit RE area) as per sketch no. RE/S&T /ALD/SK/227/82 or Latest. | ITEM 157 | 1 | NOS |
158 | 158 | TELECOM SUPPLY | ITEM 158 | ||
159 | 159 | Supply of managed SDH STM-1 ADM conferming to TEC specification no.GR/SDH-04/03 MAR 2005, with (L1.1) aggregate optical interface, order wire, fully wire and equipped for 21E1 & minimum 4/8 port 10/100Base Telectrical interface (with LCAS and GFP) and upgradeable to full 63E1s with all common cards, DDF and all other accessories, manuals etc., with required software. It shall be equipped with redundant power supply card. It shall support a minimum of 3 Nos. of E3/DS3 in a single card and the selection shall be software configurable. | ITEM 159 | 1 | No. |
160 | 160 | Supply & installation of Fibre Distribution Management System, 19" rack mountable for 2x24 fibre OFC with connector, patch cord & pigtails as per specn. No. RDSO/SPN/TC/ 37/2000 (Ver. 3) with latest amendment suitable for termination of 2x24 fibre OFC.\n | ITEM 160 | 1 | No |
161 | 161 | Supply of hardware for NMS as per required specification including one no. Monitor 19" TFT and six nos. flash RAM type pen drive as per the specifications enclosed. NMS for SDH/STM and 2 Mb Mux shall be loaded in this equipment. | ITEM 161 | 1 | No. |
162 | 162 | Supply of 2MB programmable primary digital drop insert multiplexer as per RDSO spec. IRS-TC 68/2004 or latest with conference facility and other stipulations of tender documents fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation materials, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support card needed for video conferencing and ISDN. It shall also support NMS operations from local/remote locations.\n\nThe above MUX should be equipped with following circuits.\ni) 2 wire/ 4 wire E & M VF circuits (Minimum 24 nos.)\nii) Subscriber loop circuits (Minimum 2 nos.)\niii) Exchange loop circuits (Minimum 2 nos.)\niv) Minimum 2 x 64Kbps co directional data circuits-3 nos or 64 kbps co directional data circuits - 6 nos.\n | ITEM 162 | 1 | No. |
163 | 163 | Supply of 19" covered rack (2.2m height min), vero president/Rittel make or similar with Glass front door complete with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with intergrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. | ITEM 163 | 1 | No. |
164 | 164 | Supply maintenance free VRLA secondery cells duly charged of 48V 200 AH and each 2.0 V when fully charged 200 AH capacity alongwith accessories i.e. intersell connectivity links/float, 4 nos. insulators for each cell 24 nos. of cell per set as per RDSO Spcn.IRS/S/88/2004 amendment - 1 revision with latest amendments with cuitble steel/ hylam tray battery rack to install/house batteries. | ITEM 164 | 1 | set |
165 | 165 | Suppy of 48V, 50 amps battery charger for telecom use as per No.RDSO/SPCN/TL/23/99 (ver.4) or latest in N+1 configuration i.e. using 3 modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery. It shall be equipped with surge and lightening protection of class `B' and `C' the configuration shall be decided as per site requirement. | ITEM 165 | 1 | No. |
166 | 166 | Supply of 50 pair PIJF- .63 mm cable \n | ITEM 166 | 1 | Km |
167 | 167 | Supply of CAT-6 cable 10/100/1000Mbps. | ITEM 167 | 1 | Km |
168 | 168 | Supply, Installation & commissioning of PVC type Casing -Capping 32mm 2 mtrs each piece , Thickness 1.2 mm | ITEM 168 | 1 | Km |
169 | 169 | Supply of lightening and surge arrestors of class B&C suitable for single phase supply in TT network as per amendment 5 of RDSO spec.No . RDSO/SPN/ 165/2004 or Latest and as recommended by RDSO letter No.STS/E / IPS/GENL dated 27.01.06(Amendment 5) | ITEM 169 | 1 | Set |
170 | 170 | Supply of one Quad VF 2T transformer joint assembly of VF transformers 470:470/1120:470 as per IRS TC/76/2000 with ammendment - 1 or latest | ITEM 170 | 1 | No. |
171 | 171 | Supply of DTMF 4 wire based Headquarters Equipment for Control circuits as per RDSO spec No.IRS.TC..60/93 (or latest) with power supply unit to suit RDSO Spec No.IRS.TC.72.97 (or latest) | ITEM 171 | 1 | No. |
172 | 172 | Supply, installation & commissioning of 4 wire DTMF way station Equipment as per RDSO specification No. IRS:TC:60/93 with Amnd. 4 or latest alongwith compatible way station telephone as per RDSO Spec. No. IRS:TC:38:97 with Amnd. No. 1. Item includes their, installation, testing & commissioning with contractor's all materials required for installation. | ITEM 172 | 1 | No. |
173 | 173 | Supply of 4 wire DTMF Control Telephone spec.IRS-TC-38/97 with Amendment-1 or latest Tummala make or similar) | ITEM 173 | 1 | No. |
174 | 174 | Supply, installation & commissioning of Power supply for DTMF equipment/Selective calling telephone to RDO spec. IRS:TC:72:97(or latest) with 12v 7AH battery | ITEM 174 | 1 | No. |
175 | 175 | Desk type 2 wire DTMF, 12 way selective calling calling group telephone as per RDSO specification no IRS:TC:80:2000 (Set of 12 telehones) | ITEM 175 | 1 | Set |
176 | 176 | 2 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 | ITEM 176 | 1 | km |
177 | 177 | 5 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 | ITEM 177 | 1 | km |
178 | 178 | Schedule- B ( Execution Signalling ) | ITEM 178 | ||
179 | 179 | Installation, wiring, programming, Bell test,Site acceptance test (SAT), commissioning, Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etc as per Railways practice and All Pre-commissioning tests of EI and other equipments supplied against each station, as per latest technical specifications of RDSO and OEM . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor. | ITEM 179 | ||
180 | 180 | Delhi Kishan Ganj | ITEM 180 | 1 | System |
181 | 181 | Training for O&M Staff | ITEM 181 | ||
182 | 182 | i) Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. 1 of this schedule including provision of hard copies of course modules for each trainee. | ITEM 182 | 1 | Man month |
183 | 183 | ii) Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs supplied against item no. - 1 of this schedule including provision of hard copies of course modules for each trainee. | ITEM 183 | 1 | Man month |
184 | 184 | Testing and commissioning of complete signalling system integration with outdoor gears ,slotting, etc at the staion as a whole. All artisan staff and labours required for testing and with MACLS work shall be provided by contractorfor for indoor and outdoor work. Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter,etc. shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.It also includes provision of temporaty tents/Huts,arranging lights,Chairs & tables, provision of temorary telphones,snacks/drinking water for NI staff round the clock at site etc as reqired duing the NI period in Railways. | ITEM 184 | 1 | LS |
185 | 185 | Termination of all cores of all types of Indoor/outdoor cables (Excluding termination in location boxes and terminations on items coming under item No.1 of Schedule A (Supply )after its laying, on both ends and providing number ferrule on each core. This also includes fixing of ARA terminals/disconnecting type terminal block/ 8 way strip, meggering and preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor. | ITEM 185 | 1 | Core |
186 | 186 | RELAY ROOM | ITEM 186 | ||
187 | 187 | Erection of cable termination rack. Clamping of cables, Numbering of cables with engraved aluminium strips, Supply of nuts & bolts, MS clamps & cement for massonary works.This will also include paintng of Cable/core particulars for each trminationwith contractors own paint.The place for erection of Termination Rack shall placed as decided by Site Engineer | ITEM 187 | 1 | No |
188 | 188 | Installation of relay rack assembly complete alongwith wall supports, sccaffolding, ladders/runway for cables, relay base plates etc. This includes Fixing of Relays with retaining clips, Fixing of disconnecting type terminals/ARA Terminals, PBT Fuse bases( supplied under Schedle A,) , termination of cable cores/wires, Supply of nuts & bolts, MS clamps & cement for massonary works.:This will also include Painting of Relay description on the front side and back side of the Relays as per instruction of site engineer. | ITEM 188 | 1 | No |
189 | 189 | Installation, wiring, testing and commissioning of multi channel earth leakage detector including supply of mounting arrangement. | ITEM 189 | 1 | No. |
190 | 190 | Necessary arrangement for manufacture, transportation & installation of station masters console for fixing telephones & other equipments as per instruction of Engineer incharge. This includes : All materials like 25mm thick hylum sheet etc. required for the above including sundry items like bolts & nuts, screws, MS angle / flat shall be supplied by the contractor. | ITEM 190 | 1 | Job |
191 | 191 | POWER SUPPLY/BATTERIES | ITEM 191 | ||
192 | 192 | Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system, at station/cabin as per technical specification and instructions given in Installation manual of OEM. Approval for installation drawings shall be obtained from project consultant before installation. This includes supply of all materials required for installation and initial charging of low maintenance Lead-Acid batteries (3 cycles). | ITEM 192 | 1 | System |
193 | 193 | Installation of DG set, testing and commissioning. This includes casting of vibration free foundation, installation of ASM panel, outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of ASM panel, laying of cables/wires should be carried out in HD PVC channel/ conduit pipe. This includes cost of all mateials required for installation except DG set and perASM panel. Wires/cables as extant practice on Railways and instruction of Engineer at site. | ITEM 193 | 1 | Per KVA |
194 | 194 | Installation,wiring,testing & commissioning of LT power panel with auto change-over at Central Cabin. This includes fixing of power panel.termination of LT cables & fixing of Auto-change-over management and its wiring and supply of MS angle,nuts & bolts etc. | ITEM 194 | 1 | Nos. |
195 | 195 | CABLE LAYING | ITEM 195 | ||
196 | 196 | Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. Wherever several cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. | ITEM 196 | 1 | Km |
197 | 197 | Excavation of cable trench of 1.0 m. depth & 300 mm. wide across the track width at level / track/Road crossing platform & refilling after laying DWC/RCC pipe (laying of DWC/RCC pipe shall be paid under separate item of schedule) as per cable route chart & technical specification as per Drg.NO.NR/SIG/CABLE/005. This include repairing and plastering of platform/pucca road after cable laying. | ITEM 197 | 1 | Mtr. |
198 | 198 | NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe. | ITEM 198 | ||
199 | 199 | Cutting smoothening of inside surface of chase in concrete or hard rocks having size 80mm depth & 70mm width. This work includes laying & covering of cable laid in the chase with brick (225 x 100x 75 mm) i.e. 9 bricks per meter second class bricks placed & embedded longitudinally & plastered on the top of the bricks as per drg No. RITES/SIG/GEN/025-98. This item includes the cost of bricks, cement & sand etc. | ITEM 199 | 1 | Mtr. |
200 | 200 | Supply of RCC duct 0.7x0.3X 0.26m with RCC duct cover as per drawing no.TYP/NR/SIG/CABLE/001 TO 004 including Excavation of Trench, Depth 1.2 Mtr. & width 0.3 Mtr. for placing of RCC duct with cover , in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying and placing of duct cover. The contractor has to conduct detailed site survey of the cable route. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. | ITEM 200 | ||
201 | 201 | Filling of cable duct by sieved silver/fine sand after laying of cable in relay rooms. Supply of sand shall be made by the contractor. | ITEM 201 | 1 | Cum. |
202 | 202 | Fixing/ laying of DWC/RCC pipes for laying of cables (including under-neath the track, Road crossing or other platform cutting etc.) as per drg.No.NR/SIG/CABLE/006. | ITEM 202 | 1 | Mtr. |
203 | 203 | Fixing of Galvanised iron pipe 100 mm dia. on panel buildings. This includes supply of clamps, support, nuts, bolts etc. & concreting of ends with brick masonary work including supply of cement, sand an aggregate. | ITEM 203 | 1 | Mtr. |
204 | 204 | Laying of 40/33 mm dia HDPE pipe as per approved cable route plan in the excavation trench at 1 mtr depth. | ITEM 204 | 1 | Km |
205 | 205 | Transportation of cables in roll with or without wooden drums to work site and meggering before loading and after laying, and recording the values in cable insulation register along with representative. | ITEM 205 | ||
206 | 206 | Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid . | ITEM 206 | 1 | Km. |
207 | 207 | Providing Heat Shrinkable joint for all type of S&T cable with contractor's all materials. | ITEM 207 | 1 | No. |
208 | 208 | All the materials required for the work are to be arranged by the contradtor himself at his own cost except Thermoshrinkable jointing kit which is already covered in Supply portion of the tender.After jointing the cable through test such as insulation test,Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should redo the joint free of cost. | ITEM 208 | ||
209 | 209 | POINT MACHINE | ITEM 209 | ||
210 | 210 | Installation, wiring, testing and commissioning of 110 V, DC point machine as per specifications and approved wiring diagrams. This includes: | ITEM 210 | 1 | No |
211 | 211 | i) Fixing of point machines on MS plate fixed on sleepers complete with fixing of anti theft covers, cable terminal box, ground connection. | ITEM 211 | ||
212 | 212 | ii) Fixing of insulation for gauge tie plate and crossing plate for 52 / 60 Kg. points and crossings. | ITEM 212 | ||
213 | 213 | iii) Fixing of insulation for switch extention pieces (D brackets) and leading & following stretcher bars. | ITEM 213 | ||
214 | 214 | iv) Wiring from the cable termination box to the point machine as per specifications. | ITEM 214 | ||
215 | 215 | v) All smithy works. | ITEM 215 | ||
216 | 216 | vi) Supply of MS plates, flat, angle, bolts, nuts, pins as required.This item also includess supply & fixing of GI pipe bend for the protection of cable from cable termination box to piont machine. | ITEM 216 | ||
217 | 217 | vii) Testing the point machines from point of operation including testing with 5 mm test piece. | ITEM 217 | ||
218 | 218 | P-way works required before provision of point machines such as .squaring of switches, packing and leveling/alignment of track,easing or rails on either side of points to be interlocked,making proper spacing of sleepers etc | ITEM 218 | 1 | Job |
219 | 219 | Fabrication, supply and erection of number plate for point machine as per Drg. No. RITES/S&T/ROU/ PMNP-01 and as per instruction of Site Engineer. This includes supply of MS Plate (Size: 350mm x 250mm, 3mm thick), MS Angle (Size: 25mm x 25mm, 3mm thick), Cement, Sand, Aggregate, Paint and all other material required for this work. All the smithy mechanical and electrical work/arrangement shall be done by the contractor at his own cost. Point Number shall be written in black on yellow background in 150mm height on both side of the plate. | ITEM 219 | 1 | No. |
220 | 220 | Track Circuit | ITEM 220 | ||
221 | 221 | Fixing & wiring of track circuit equipment such as battery chargers, track feed resistance, `B' type choke, relays batteries etc. as per approved wiring diagram in location box. This includes :- \n(i)Supply, fabrication & fixing of duly varnish teakwood planks of 25 mm thick. \n(ii)Supply of fixing material. | ITEM 221 | 1 | No. |
222 | 222 | Installation, wiring, testing & commissioning of DC track circuits as per approved standard practice. This includes :\na) Installation of all types of lead wires, jumpers and rail head continuity bonds ,insulation joints using contractors own consumables & pin brazing machine \nb) Fixing of track lead junction boxes as per drg. No. RITES/SIG/GEN/039-2007. This also includes painting of TLJB.\nc) Charging of track Batteries, Energising the track circuit and testing with 0.5 ohms train shunt resistance. | ITEM 222 | ||
223 | 223 | i) On straight portion of track | ITEM 223 | 1 | No. |
224 | 224 | ii) On point and crossing portion of track | ITEM 224 | 1 | No. |
225 | 225 | Axle counter | ITEM 225 | ||
226 | 226 | Intallation, programming, Testing along Commissioning of Central Evaluators of MSDAC (includes & OEM certification), wiring from CT rack to the Central Evaluator, Installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories, with their own material. Note: 1. Variation in detection points and/or track sections upto (+) 10% shall have no cost bearing. 2. Installation of detection points and line side electronics box is not included in this item. | ITEM 226 | 1 | DP |
227 | 227 | Installation, Testing & Commissioning of track device (double rail contact) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to track side housing and making its terminations. Termination of 4Quad cable in track side electronic box. Fixing of deflector plates. (Double walled antirodent corrugated pipe made up of high density polyethylene of required diameter and all other accessories as per site requirement to be supplied by the firm & installation of EJB/ Track side electronic box inside the track side housing, including supply of wires and other accessories. | ITEM 227 | 1 | No |
228 | 228 | P-way work required for provision of Axle counter track detection devices to be fixed on rails including work involving re-spacing of sleepers, packing of sleepers etc | ITEM 228 | 1 | DP |
229 | 229 | Installation, wiring, testing and commissioning of Block Instrument - Block proving by Axle Counter (BPAC) along with Universal Fail Safe Block Interface (UFSBI). This includes supply of all the materials (which are not covered in supply schedule) required for the job . | ITEM 229 | ||
230 | 230 | COLOUR LIGHT SIGNALS | ITEM 230 | ||
231 | 231 | Excavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per drg.No.SK-15/10. This includes : Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM 231 | 1 | No. |
232 | 232 | Erection of 2 aspect colour light signals.This includes : | ITEM 232 | 1 | No. |
233 | 233 | i) Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity. | ITEM 233 | ||
234 | 234 | ii) Wiring & testing of signal unit as per the specifications and directives of engineer at site. | ITEM 234 | ||
235 | 235 | Erection of 3 aspect colour light signals.This includes : | ITEM 235 | 1 | No |
236 | 236 | Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity. | ITEM 236 | ||
237 | 237 | Wiring & testing of signal unit as per the specifications and directives of engineer at site. | ITEM 237 | ||
238 | 238 | Testing & commissioning of 2 /3/4aspect colour light signals. | ITEM 238 | 1 | No |
239 | 239 | Excavation of pit, casting & plastering of concrete foundation for shunt signal. As per Drg. SK-16/10. This includes : Supply of foundation nuts & Bolts, cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM 239 | 1 | No |
240 | 240 | Erection of shunt signal. This includes : | ITEM 240 | 1 | No. |
241 | 241 | a). Erection of surface base, shunt signal post, shunt signal unit. | ITEM 241 | ||
242 | 242 | b). Fixing of hoods and LED lamps with regulating transformer. | ITEM 242 | ||
243 | 243 | c). Termination of the tail cable in the signal unit. | ITEM 243 | ||
244 | 244 | d). Wiring of shunt signal unit with wiring material. | ITEM 244 | ||
245 | 245 | e) Necessary arrangement of material to be used by bidder own arrangement. | ITEM 245 | ||
246 | 246 | APPARATUS CASE | ITEM 246 | ||
247 | 247 | Excavation of pit, casting of concrete foundations for full location box as per Drg.No.NR SK -18/10. This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM 247 | 1 | No. |
248 | 248 | Erection of full location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This includes - | ITEM 248 | 1 | No |
249 | 249 | (i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc. | ITEM 249 | ||
250 | 250 | (ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of cables with contractors own material | ITEM 250 | ||
251 | 251 | (iii). Filling up pit inside the location box by sand and plastering on the top of the sand. | ITEM 251 | ||
252 | 252 | (iv). Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams. | ITEM 252 | ||
253 | 253 | Excavation of pit, casting of concrete foundations for half location box as per as per TS para.-8 &9 and Drg.No.SK- 17/10. This includes: (i) Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers. (ii) Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM 253 | 1 | No. |
254 | 254 | Erection of half location box on foundation including fixing of `E' type lock & locking arrangement wiring, testing & commissioning as per approved\ndisposition plan & wiring diagram. This includes :\n(i) Supply & fixing of hylum sheet, resin bonded 10 mm thick grade P3 for fixing ARA terminal, fuse blocks etc.\n(ii) Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.\n(iii) Filling up pit inside the location box by sand and plastering on the top of the sand.\n(iv) Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays.\n(v) Fixing of terminals, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams and dwg. No. RITES/SIG/GEN/054-09 | ITEM 254 | 1 | No. |
255 | 255 | Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signal unit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98, RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes:\n(i) Diging of pit in earth 3 m deep.\n(ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98.\n(iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal.\n(iv) Connecting the equipment through earth lead wire & soldering.\n(v) Supply of cement, wiring material & soldering material.\n | ITEM 255 | 1 | No. |
256 | 256 | Dismantling of the following: - | ITEM 256 | ||
257 | 257 | i) Signal posts/BSLB/SLB/Stop Board. | ITEM 257 | 1 | No. |
258 | 258 | ii) Steel apparatus case with fittings. | ITEM 258 | ||
259 | 259 | iii) Relay racks with all fittings, battery racks complete, Equipment rack complete, SM`s slide. | ITEM 259 | 1 | No. |
260 | 260 | iv)Battery charger, Battery set etc.TLBI, DLBI and other Misc. equipments. | ITEM 260 | 1 | No. |
261 | 261 | v) Complete lever frames, inside and Outside leads, all ground gears. | ITEM 261 | ||
262 | 262 | vi) Lifting barrier complete. | ITEM 262 | 1 | No. |
263 | 263 | vii) TLJB/Point JB | ITEM 263 | 1 | No. |
264 | 264 | viii) Electric Point Machine | ITEM 264 | 1 | No. |
265 | 265 | ix) Operating cum indication Panel. | ITEM 265 | ||
266 | 266 | x) Location Foundation/ Signal Foundation. | ITEM 266 | 1 | No. |
267 | 267 | PAINTING | ITEM 267 | ||
268 | 268 | Painting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint. | ITEM 268 | ||
269 | 269 | i) Full case | ITEM 269 | 1 | No |
270 | 270 | ii) Half case | ITEM 270 | 1 | No. |
271 | 271 | Painting of Main signal post with signal unit, surface base complete with route indicator, dependent shunt, calling On unit, ladder fittings as per Indian.Rlys. standard practice. | ITEM 271 | 1 | No |
272 | 272 | Painting of two coats of enamel paint black Asian and Aiuminium white as approved by Site engineer over one coat of primer on Shunt signal unit , base and post | ITEM 272 | 1 | No |
273 | 273 | Painting of two coats of enamel paint black Asian and red oxide as approved by Site engineer over one coat of primer on point machine and ground connection respectively | ITEM 273 | 1 | No |
274 | 274 | Necessary arrangement of material, installation & commissionig of Pre-wired Crank Handle cum key lock relay box along with LEDs, TEKNIC make push buttons, 8-way terminal strips, string rod etc. as per instructions of Engineer at site. | ITEM 274 | 1 | No. |
275 | 275 | Cement concrete work for miscellaneous items with supply of cement, sand, stone chips and mixing in the ratio 1:3:6. This item includes excavation, raming, curing and plastering with cement & sand mixture (stone chips size not exceeding 40mm). | ITEM 275 | 1 | Cu.Mtr |
276 | 276 | Providing brick massonary in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor's own IInd nd class bricks including excavation curing, grouting,bolting etc. Whereever required bricks sand and cement to be supplied by the contractor. | ITEM 276 | 1 | Cu.Mtr |
277 | 277 | Foundation & fixing all types of cranks & A type foundation | ITEM 277 | ||
278 | 278 | All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no.RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road by usingpipe of size 120 mm outer dia,103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. (This item will be used for track crossing of running lines). | ITEM 278 | 1 | mt |
279 | 279 | Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn/laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of item no. (6h) of this schedule. OFC and HDPE pipe shall be supplied by the railway. | ITEM 279 | 1 | KM |
280 | 280 | LOADING AND UNLOADING | ITEM 280 | ||
281 | 281 | Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation,\ndismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site.JCB | ITEM 281 | ||
282 | 282 | Hiring of vehicle | ITEM 282 | 1 | MONTH |
283 | 283 | Work site Office | ITEM 283 | 1 | each |
284 | 284 | ( i)Rent , Running and maintenance of site office | ITEM 284 | 1 | MONTH |
285 | 285 | Execution of NI and commissioning works facilating the furniture, tents, light, and all general items necessary during Pre-NI & NI it includes drinking water and food package for staff as per site incharge | ITEM 285 | 1 | LS |
286 | 286 | Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods,leveling and dressing etc. as per instruction of Engineer at site. | ITEM 286 | ||
287 | 287 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signalling system, releasing the cable coils to give access forshifting/ turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. if theexisting earth connection to the location boxes are disturbed the earth wires shall be the properly re-connected. (All materials required for the work shall be supplied by the contractor) (i) Shifting of apparatus case (full).Shifting of location box | ITEM 287 | 1 | No |
288 | 288 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signalling system, releasing the cable coils to give access for shifting/ turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly re-connected. (All materials required for the work shall be supplied by the contractor) (ii) Shifting of apparatus case (Half). | ITEM 288 | 1 | NO |
289 | 289 | Installation testing and comissioning of electrically operated lifting barrier complete with casting of cement concreets foundations for padestals and boom rest post .Electric Lifting barrier shall be commissioned only if the installation is certified fit by theOEM and certificate from OEM is to be arranged by the contractor. | ITEM 289 | ||
290 | 290 | Installation & Commissioning of Sliding Boom Gate as per technical specification attached. | ITEM 290 | ||
291 | 291 | Installation, testing &commissioning of High Availability Single Section Digital Axle Counter Systemcomplete by OEM or itsauthorised dealer. The axle counter will be High Availability Single Section type with two\ndetection points and it ispossible to install it without trolley protection track circuit.The axle counter must consist of following: (a) Mounting of high frequency TX and RX coil-2 sets, each set consist of web mounting type 2 Nos. of TX and 2 Nos. of RX. TX & RX shall be supplied by Rly. (b) Mounting of track side digital axle counter Unit-2 Nos. (c) Fixing of vitalrelays etc. duly wired-2 Nos.(d) Clamping with deflectorplate andhardware formounting of two set of TX & RX\ncoil. (e) Resetting arrangementof each axle counter. (f) All the\nwiring material required forinstallation and commissioning shall be arranged by contractor.\n(g) This also includesintegration with existing\nSGE/Tokenless/Token blockinstruments were required as per instructions of siteengineer. The wire and other wiring material will be arranged by contractor at site. | ITEM 291 | ||
292 | 292 | Installation of desk type magneto telephone with all accessories including standard battery box and 3nos. of 6I cells. All materials for this installation including standard battery box and 6I cells will be supplied by the contractor. Only desk type magneto telephone will be supplied by Railway(included as separate item of this schedule). | ITEM 292 | 1 | nos |
293 | 293 | Shifting of existing SM office telecom equipments to new SM office such as control telephone, PRS equipment etc . | ITEM 293 | 1 | LS |
294 | 294 | TELECOM EXECUTION | ITEM 294 | ||
295 | 295 | Installation of fiber distribution management system with contractor's own installation material, splicing and termination of 2x24 fiber OFC, routing dressing fibers as per instructions of Engineer incharge. | ITEM 295 | 1 | No |
296 | 296 | Installation, testing and commisioning of NMS including uploading of STM/PD MUX.All the required fixing hardware material will be arrenged by contractor free of cost. | ITEM 296 | 1 | No |
297 | 297 | Installation and wiring of SDH / STMs and PD Mux supplied with all accessories, DDF with miniature ‘U’ link type for 63 E1s, runway ladder etc in already installed 42-U Euro rack. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH with all interface cards to the 48V Bus including supply of wires and connectors, termination of all E1s on DDF. This includes all the sundry material required for installation. | ITEM 297 | 1 | No |
298 | 298 | Supply and installation of Optical Fiber termination box as per spec No. DPG/G/FIB-01/02 Mar 99 or DOT/G/FTB-01, Jan 93 or with latest amendment and splicing of all the fibers inside the termination box with provision of taking out OFC as required. This includes supply of all installation acccessories required to complete th installation as per spec No. G/OFJ-01/03 June 99 with latest amendment 10 mtr long patch cord as per spec. No. G/OJF-01/01 with connector as per code of practice for installation and commissioning of OFC. | ITEM 298 | 1 | No |
299 | 299 | Installation, of 19" 42 U Rack with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with intergrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack.configuration shall be decided as per site requirement.All required fixing hardware material will be arrenged by contractor free of cost. | ITEM 299 | 1 | No |
300 | 300 | Schedule C : Supply and execution of Station Building Works ( Delhi Kisanganj) | ITEM 300 | ||
301 | 301 | Foundation | ITEM 301 | ||
302 | 302 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 3 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 3 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | ITEM 302 | 1 | Cum. |
303 | 303 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. In layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. | ITEM 303 | 1 | Cum. |
304 | 304 | Providing and laying in position cement concrete of specified grade excludingbthe cost of centering and shuttering - All work up to plinth level : | ITEM 304 | ||
305 | 305 | a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | ITEM 305 | 1 | Cum |
306 | 306 | b) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | ITEM 306 | 1 | Cum |
307 | 307 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :-Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). | ITEM 307 | ||
308 | 308 | a) All works upto Plinth Level | ITEM 308 | 1 | Cum. |
309 | 309 | b) All works above plinth level upto floor V level | ITEM 309 | 1 | Cum. |
310 | 310 | Supplying and filling in plinth with sand under floors including,watering,ramming, consolidating and dressing complete. | ITEM 310 | 1 | Cum. |
311 | 311 | Brick work with F.P.S bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1Cement : 6 coarse sand) | ITEM 311 | 1 | Cum. |
312 | 312 | Brick work with F.P.S bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 Cement : 6 coarse sand) | ITEM 312 | 1 | Cum. |
313 | 313 | Half brick masonary with F.P.S bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement:4 coarse sand) | ITEM 313 | 1 | Sqm |
314 | 314 | Half brick masonary with F.P.S bricks of class designation 7.5 in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement:4 coarse sand) | ITEM 314 | 1 | Sqm. |
315 | 315 | Brick work with bricks of class designation 7.5 in foundation and plinth in Cement mortar:1:4 (1 cement: 4 coarse sand ), | ITEM 315 | 1 | Cum. |
316 | 316 | a) Extra for brickwork in superstructure above plinth level upto floor V level. - CM : 1:4 (1 cement: 4 coarse sand) | ITEM 316 | 1 | Cum. |
317 | 317 | Applying a coat of residual petroleum bitumen (of grade of VG-10) of penetration 80/100 of approved quality using 1.7 kg per square metre after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil | ITEM 317 | 1 | sqm |
318 | 318 | Supplying and placing in position High Strength Deformed Steel bars reinforcemetn . (confirming to IS 1786 Grade Fe 500) for RCC works including transporting the steel straightening, cleaning, cutting, bending, binding to required shapes and lenghts as per drawing including the cost of binding wire 18 SWG as needed. Steel shall be from main producers such as SAIL,RINL & TISCO. Rates shall include the cost of protective coating of truncated inhibitedcement slurry. | ITEM 318 | 1 | Kg |
319 | 319 | Providing and fixing T iron Frames for Doors, Window and Ventileters of mild steel Tee section, joints mitred and welded, including fixing of necessary butt hinges and screws and applying in prime coat of approved steel primer.\nFixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10 cm of C.C. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | ITEM 319 | 1 | Kg |
320 | 320 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete : | ITEM 320 | ||
321 | 321 | a) 25x64x1.90 mm | ITEM 321 | 1 | Each |
322 | 322 | b) 100X58X1.90 mm | ITEM 322 | 1 | Each |
323 | 323 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. | ITEM 323 | 1 | Kg. |
324 | 324 | a) Fixed to steel windows by welding | ITEM 324 | ||
325 | 325 | b) Fixed to openings /wooden frames with rawl plugs screws etc. | ITEM 325 | 1 | Kg |
326 | 326 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) | ITEM 326 | 1 | Each |
327 | 327 | 12mm cement plaster of mix 1:6 (1cement : 6 coarse sand). | ITEM 327 | 1 | Sqm. |
328 | 328 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1cement : 6 coarse sand). | ITEM 328 | 1 | Sqm. |
329 | 329 | 6mm cement plaster to ceilling of mix 1:3(1cement: 3 fine sand). | ITEM 329 | 1 | Sqm. |
330 | 330 | 12 mm cement plaster finished with a floating coat of neat cement of mix : \n1:4 (1 cement: 4 fine sand) | ITEM 330 | 1 | sqm |
331 | 331 | Providing and fixing 10 mm thick acid and or/ alkali resistance tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS: 4457, complete as per the direction of enfgineer-in-charge. | ITEM 331 | ||
332 | 332 | a) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement:4 coarse sand) - Acid and alkali resistant tile | ITEM 332 | 1 | sqm |
333 | 333 | b) in dado/skirting on 12 mm thick mortar1:4 (1 acid proof cement: 4 coarse sand) - Acid and alkali resistant tile | ITEM 333 | 1 | sqm |
334 | 334 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil | ITEM 334 | 1 | sqm |
335 | 335 | Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge | ITEM 335 | ||
336 | 336 | Providing and fixing 1st quality wall ceramic glazed wall tiles conforming to IS:15622 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colours, shades except begundy, bottle green , black of any size as approved by Enginner -in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement :3 Coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shades complete. | ITEM 336 | 1 | Sqm. |
337 | 337 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality confirming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. | ITEM 337 | 1 | Sqm. |
338 | 338 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement motar 1:4 (1 cement : 4 coarse sand) - 25 mm thick. | ITEM 338 | ||
339 | 339 | Kota stone slab 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement motar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. | ITEM 339 | ||
340 | 340 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating no less than 120 gm/sqm) duly filled with vermuculite based concrete mix suitable for mounting 60 minutes fire rated door shutters. The frame isfitted with intumuscent fire seal strip of size 10x4 mm (minimum) alroundhe frame and fixing with dash fastener of approved size and make,including applying a coat of approved brand fire resistant primer etc.complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately) | ITEM 340 | ||
341 | 341 | Providing and fixing 50 mm thick glazed fire resistant door shutters of60 minutes fire rating conforming to IS:3614 (Part-II), tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mountingon door frame, consisting of vertical styles, lock rail, top rail 100 mmwide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinccoating not less than 120 gm/m2) duly filled FR insulation material andfixing with necessary stainless steel ball bearing hinges of approvedmake, including applying a coat of approved fire resistant primer etc. allcomplete as per direction of Engineer-in-charge (panneling to be paidfor separately). | ITEM 341 | ||
342 | 342 | Cement Plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement of 18 mm thick. | ITEM 342 | 1 | Sqm. |
343 | 343 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with absorption less than 0.08% and confirming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), including grouting the joints with white cement and matching pigments etc ; size of tile 600x6000 mm | ITEM 343 | 1 | Sqm. |
344 | 344 | Providing and laying Antiskid Ceramictiles of approved quality of size30cmx30cm and confirming to IS15622-2006 (Group-BIIA) for anti skid flooring in required position laid on a be of 1:4 cement mortar including cement float, filling joint with cements slurry cieaning curing etc complete.. | ITEM 344 | ||
345 | 345 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. | ITEM 345 | 1 | Sqm. |
346 | 346 | Distempering with oil bound washable distemper of approved brand(Asian,Nerolack) and manufacture to give an even shade new work (two or more coats) over and including priming coat with cement primer. | ITEM 346 | 1 | Sqm. |
347 | 347 | Making plinth protection 50 mm thick of cement concrete 1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | ITEM 347 | 1 | sqm |
348 | 348 | Finishing walls with water proofing cement paint "Snowcem - Plus" of M/s Asian, Berger Ltd. or equivalent of required shade:New work (Two or more coats applied @ 3.84 Kg/10 Sqm.) | ITEM 348 | 1 | Sqm. |
349 | 349 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (External work) | ITEM 349 | ||
350 | 350 | a) 20 mm dia. nominal bore. | ITEM 350 | 1 | Mtr. |
351 | 351 | b) 25mm dia. nominal bore. | ITEM 351 | 1 | Mtr. |
352 | 352 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40mm nominal bore. | ITEM 352 | 1 | Each |
353 | 353 | Providing and Fixing brass stop cock of approved quality. 15mm nominal bore. | ITEM 353 | 1 | Each |
354 | 354 | Providing and Fixing C.P.Brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms. | ITEM 354 | ||
355 | 355 | a) 15mm nominal bore. | ITEM 355 | 1 | Each |
356 | 356 | Providing and Fixing C.P.Brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | ITEM 356 | ||
357 | 357 | a) 15mm nominal bore | ITEM 357 | 1 | Each |
358 | 358 | Providing and Fixing G.I. Pipes complete with GI.Fittings and clamps, including cutting and making good the walls etc. (internal work). | ITEM 358 | ||
359 | 359 | a) 15mm dia. Nominal bore. | ITEM 359 | 1 | Mtr. |
360 | 360 | b) 25mm dia nominal bore. | ITEM 360 | 1 | Mtr. |
361 | 361 | Providing and Fixing gun metal gate value with CI wheel of approved quality (screwed end) 25mm Nominal bore. | ITEM 361 | 1 | Each |
362 | 362 | Providing and fixing water closet squatting pan (Indian type W.C. Pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, Parryware /Hindware / Seabird / Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous chinaOrissa pattern W.C. pan of size 580 x 440mm with integral type foot rests. | ITEM 362 | 1 | Each |
363 | 363 | Providing and Fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms (Prayag or equivalent) | ITEM 363 | 1 | Each |
364 | 364 | Providing and Fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 88gms (Prayag or equivalent) | ITEM 364 | 1 | Each |
365 | 365 | Providing and Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP Brass screws with concealed fitting arrangement of approved quality colour and make (Prayag or equivalent) 450mm long towel rail with total length of 495mm, 78mm wide and effective hight of 88mm, weighin not less than 170gms. | ITEM 365 | 1 | Each |
366 | 366 | Providing and Fixing PTMT shelf 440mm long, 124mm width and 36mm height of approved quality, colour and make, weighing not less than 300gms (Prayag or equivalent) | ITEM 366 | 1 | Each |
367 | 367 | Constructing masonary Chamber 60 x 60 x 75cm inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I.surface box 100mm, Top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement: 5 fine sand : 10 graded stone aggregaten 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. -With F.P.S. bricks. | ITEM 367 | 1 | Each |
368 | 368 | Constructing masonry chamber 90x90x100 cm, inside with 75 class designation brick work in cement morter 1:4 (1 cement:4 fine sand) for sluice valve, with C.I. surface box 100mm. Top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) neccessary excavation foundation concrete 1:5:10(1 cement:5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S bricks. | ITEM 368 | 1 | Each |
369 | 369 | Providing and fixing wash basin with C.I./M.S brackets, 15mm C.P brass pillar taps,Kingston / Gem / Techno / Parko, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: Flat back wash basin size 550 x 400mm with single 15mm C.P. brass pillar tap. | ITEM 369 | 1 | Each |
370 | 370 | Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete. | ITEM 370 | 1 | Each |
371 | 371 | Providing and fixing soil, waste and vent pipes : 100mm dia. sand cast iron S & S pipe. | ITEM 371 | 1 | Mtr. |
372 | 372 | Providing and Fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe,40mm dia. | ITEM 372 | 1 | Each |
373 | 373 | Providing and fixing 100mm sand cast Iron grating for gully trap. | ITEM 373 | 1 | Each |
374 | 374 | Providing & fixing 100mm S.C.I. trap with 100mm inlet and 100mm outlet. | ITEM 374 | 1 | Each |
375 | 375 | Providing and fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (1) Single socketed pipes. 110mm diameter. | ITEM 375 | 1 | Mtr. |
376 | 376 | a) Bend 87.5 degree,110mm bend | ITEM 376 | 1 | Each |
377 | 377 | b) Shoe (plain), 110mm shoe | ITEM 377 | 1 | Each |
378 | 378 | Providing and fixing M.S.holder bat clamps of approved design to C.I. or S.C.I. Rain water pipes embeded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and cost of cutting holes and making good the walls etc. 100mm diameter. | ITEM 378 | 1 | Each |
379 | 379 | Providing and placing on tarrace (at all floor levels) polyethylene water storage tank IS:12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, Star, Lotus or equivalent having valid ISI License). | ITEM 379 | 1 | Ltr. |
380 | 380 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete – 150 mm dia. | ITEM 380 | 1 | each |
381 | 381 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : | ITEM 381 | ||
382 | 382 | a) 150 mm diamete | ITEM 382 | 1 | Mtr. |
383 | 383 | Providing and Fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: | ITEM 383 | ||
384 | 384 | a) 300x10mm | ITEM 384 | 1 | Each |
385 | 385 | b) 250x10 mm | ITEM 385 | 1 | Each |
386 | 386 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required color or shade with necessary screws etc. Complete 125mm. | ITEM 386 | 1 | Each |
387 | 387 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:\n250 x 16 mm | ITEM 387 | 1 | Each |
388 | 388 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side/top/centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc.complete of standard rolled sections, joints mitred and welded and sash bars tenoned and riveted with 15 x 3mm lugs, 10cm long, embedded in cement concrete blocks 15 x 10 x 10cm of 1:3:6 (1cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and apriming coat of approved steel primer excluding the coast of metal beading and other fittings except necessary hinges of pivots complete as per approved design.(sectional weight of only steel members shall be measured for payment). | ITEM 388 | ||
389 | 389 | Providing and fixing hand Rail of approved size by welding etc to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer.(M.S. tube) | ITEM 389 | 1 | Mtr |
390 | 390 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete | ITEM 390 | 1 | Kg |
391 | 391 | a) Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. | ITEM 391 | 1 | Kg |
392 | 392 | 9.118 Providing and fixing to existing door frames. | ITEM 392 | ||
393 | 393 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheet shall be manufactured out of 2400 TEX panel rovigs incorporatingminimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent clear or pigmented, textured or smooth as specified | ITEM 393 | ||
394 | 394 | a) 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified | ITEM 394 | ||
395 | 395 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle\niron and 3 mm M.S. gusset plates at the junctions and corners, all necessary\nfittings complete, including applying a priming coat of approved steel primer.\n10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces | ITEM 395 | 1 | sqm |
396 | 396 | Using flats 30x6mm for diagonal braces and central cross piece | ITEM 396 | 1 | sqm |
397 | 397 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : | ITEM 397 | ||
398 | 398 | a) For fixed portion | ITEM 398 | ||
399 | 399 | b) Anodised aluminium (anodised transparent or dyed to required shade according\nto IS: 1868, Minimum anodic coating of grade AC 15) | ITEM 399 | ||
400 | 400 | i) window,door&partition | ITEM 400 | 1 | kilogram |
401 | 401 | c) For shutters of doors, windows & ventilators including providing and fixing\nhinges/ pivots and making provision for fixing of fittings wherever required\nincluding the cost of EPDM rubber / neoprene gasket required (Fittings shall\nbe paid for separately | ITEM 401 | ||
402 | 402 | d) Anodised aluminium (anodised transparent or dyed to required shade according\nto IS: 1868, Minimum anodic coating of grade AC 15) | ITEM 402 | ||
403 | 403 | i) window,door&partition | ITEM 403 | 1 | kilogram |
404 | 404 | Providing and fixing glazing in aluminium door, window, ventilator shutters\nand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per\nthe architectural drawings and the directions of engineer-in-charge . (Cost of\naluminium snap beading shall be paid in basic item): | ITEM 404 | ||
405 | 405 | a) With float glass panes of 5 mm thickness (weight notless than 12.50 kg/ sqm) | ITEM 405 | 1 | sqm |
406 | 406 | b) Providing and fixing aluminium casement windows fastener of requiredlength for aluminium windows with necessary screws etc. complete | ITEM 406 | ||
407 | 407 | c) Anodized (AC 15) aluminium | ITEM 407 | 1 | each |
408 | 408 | 24 mm thick factory made PVC door shutters made of stylesand rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides.The styles and rails mitred and joint at the corners by meansof M.S. galvanised/ plastic brackets of size 75x220 mm havingwall thickness 1.0 mm and stainless steel screws. The stylesof the shutter reinforced by inserting galvanised M.S. tube ofsize 20x20 mm and 1 mm (± 0.1 mm) wall thickness. Thelock rail made up of 'H' section, a uPVC hollow section of size100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to theshutter styles by means of plastic/galvanised M.S. 'U' cleats.The shutter frame filled with a uPVC multi-chambered singleThe shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness . The panelsfilled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer's specification anddirection of Engineer-in-charge. | ITEM 408 | 1 | sqm |
409 | 409 | Providing and fixing factory made P.V.C. door frame of size 50x47 mmwith awall thickness of 5 mm, made out of extruded 5mm rigid PVCfoam sheet, mitred at corners and joined with 2 Nos of 150 mm longbrackets of 15x15 mm M.S. square tube, the vertical door frame profilesto be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDMrubber gasket weather seal to be provided through out the frame. Thedoor frame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer’s specification and direction of Engineein-Charge. | ITEM 409 | 1 | metre |
410 | 410 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths inter - locked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade no.2 and M.S. top cover of required thickness for rolling shutters. 80 x 1.20 mm M.S. laths with 1.2 mm thick top cover. | ITEM 410 | ||
411 | 411 | a) Providing & fixing ball bearing for rolling shutters. | ITEM 411 | ||
412 | 412 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and\nclerestory windows using wire gauge with average width of aperture 1.4 mm in\nboth directions with wire of dia 0.63 mm all complete | ITEM 412 | ||
413 | 413 | a) With 12 mm mild steel U beading | ITEM 413 | 1 | sqm |
414 | 414 | Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction ofEngineer-in-charge | ITEM 414 | ||
415 | 415 | a) Made of G.I. wire of dia 4 mm | ITEM 415 | ||
416 | 416 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | ITEM 416 | 1 | cum |
417 | 417 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced\nGypsum) false ceiling tiles of Size 595x595 mm of approved texture, design\nand patterns having moisture content less than 2%, humidity resistance of\n99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476\n(part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal\nlevel suspended on inter-locking metal T-Grid of hot dipped galvanised iron\nsection of 0.33mm thick (galvanized @ 120 grams per sqm including both\nsides) comprising of main-T runners of size 15x32 mm of length 3000 mm,\ncross - T of size 15x32 mm of length 1200 mm and secondary intermediate\ncross-T of size 15x32 mm of length 600mm to form grid module of size 600 x\n600 mm, suspended from ceiling using galvanised mild steel items (galvanizing\n@ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners,\n6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level\nadjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size\n24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with\nthe help of plastic rawl plugs at 450 mm center to center and 40 mm long dry\nwall wood screws. The work shall be carried out as per specifications, drawing\nand as per directions of the Engineer-in-Charge.\n26.26.1 With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. | ITEM 417 | 1 | sqm |
418 | 418 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge. | ITEM 418 | ||
419 | 419 | Extra for cutting reinforcement bars manually/ by mechanical meansin R.C.C. or R.B. work (Payment shall be made on the crosssectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge | ITEM 419 | ||
420 | 420 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge | ITEM 420 | ||
421 | 421 | a) In cement mortar | ITEM 421 | ||
422 | 422 | b) Removing mortar from bricks and cleaning bricks including stackingwithin a lead of 50 m (stacks of cleaned bricks shall be measured): | ITEM 422 | ||
423 | 423 | c) From brick work in cement mortar | ITEM 423 | ||
424 | 424 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead : | ITEM 424 | ||
425 | 425 | a) Of area 3 sq. metres and below | ITEM 425 | ||
426 | 426 | b) Of area beyond 3 sq. metres | ITEM 426 | ||
427 | 427 | Centering and shuttering including strutting, propping etc. and removal of form for all heights Foundations, footings, bases of columns, etc. for mass concrete : | ITEM 427 | 1 | sqm |
428 | 428 | a) Lintels, beams, plinth beams, girders, bressumers and\n cantilevers | ITEM 428 | 1 | sqm |
429 | 429 | b) Suspended floors, roofs, landings, balconies and access\n platform | ITEM 429 | 1 | sqm |
430 | 430 | c) Columns, Pillars, Piers, Abutments, Posts and Struts | ITEM 430 | 1 | sqm |
431 | 431 | pvc pipe for electrical work 25mm dia | ITEM 431 | 1 | Rm |
432 | 432 | Schedule D : Supply and execution of Goomty Works( Delhi Kisanganj) | ITEM 432 | ||
433 | 433 | Foundation | ITEM 433 | ||
434 | 434 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 3 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 3 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | ITEM 434 | 1 | Cum. |
435 | 435 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. In layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. | ITEM 435 | 1 | Cum. |
436 | 436 | Providing and laying in position cement concrete of specified grade excludingbthe cost of centering and shuttering - All work up to plinth level : | ITEM 436 | ||
437 | 437 | a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | ITEM 437 | 1 | Cum |
438 | 438 | b) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | ITEM 438 | 1 | Cum |
439 | 439 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :-Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). | ITEM 439 | ||
440 | 440 | a) All works upto Plinth Level | ITEM 440 | 1 | Cum. |
441 | 441 | b) All works above plinth level upto floor V level | ITEM 441 | 1 | Cum. |
442 | 442 | Supplying and filling in plinth with sand under floors including,watering,ramming, consolidating and dressing complete. | ITEM 442 | 1 | Cum. |
443 | 443 | Brick work with F.P.S bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1Cement : 6 coarse sand) | ITEM 443 | 1 | Cum. |
444 | 444 | Brick work with F.P.S bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 Cement : 6 coarse sand) | ITEM 444 | 1 | Cum. |
445 | 445 | Half brick masonary with F.P.S bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement:4 coarse sand) | ITEM 445 | 1 | Sqm |
446 | 446 | Half brick masonary with F.P.S bricks of class designation 7.5 in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement:4 coarse sand) | ITEM 446 | 1 | Sqm. |
447 | 447 | Brick work with bricks of class designation 7.5 in foundation and plinth in Cement mortar:1:4 (1 cement: 4 coarse sand ), | ITEM 447 | 1 | Cum. |
448 | 448 | b) Extra for brickwork in superstructure above plinth level upto floor V level. - CM : 1:4 (1 cement: 4 coarse sand) | ITEM 448 | 1 | Cum. |
449 | 449 | Applying a coat of residual petroleum bitumen (of grade of VG-10) of penetration 80/100 of approved quality using 1.7 kg per square metre after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil | ITEM 449 | 1 | sqm |
450 | 450 | Supplying and placing in position High Strength Deformed Steel bars reinforcemetn . (confirming to IS 1786 Grade Fe 500) for RCC works including transporting the steel straightening, cleaning, cutting, bending, binding to required shapes and lenghts as per drawing including the cost of binding wire 18 SWG as needed. Steel shall be from main producers such as SAIL,RINL & TISCO. Rates shall include the cost of protective coating of truncated inhibitedcement slurry. | ITEM 450 | 1 | Kg |
451 | 451 | Providing and fixing T iron Frames for Doors, Window and Ventileters of mild steel Tee section, joints mitred and welded, including fixing of necessary butt hinges and screws and applying in prime coat of approved steel primer.\nFixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10 cm of C.C. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | ITEM 451 | 1 | Kg |
452 | 452 | Providing and fixing ISI marked flush door shutters confirming to IS 2202 (Part -I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters | ITEM 452 | ||
453 | 453 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete : | ITEM 453 | ||
454 | 454 | a) 25x64x1.90 mm | ITEM 454 | 1 | Each |
455 | 455 | b) 100X58X1.90 mm | ITEM 455 | 1 | Each |
456 | 456 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths inter - locked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade no.2 and M.S. top cover of required thickness for rolling shutters. 80 x 1.20 mm M.S. laths with 1.2 mm thick top cover. | ITEM 456 | ||
457 | 457 | a) Providing & fixing ball bearing for rolling shutters. | ITEM 457 | ||
458 | 458 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. | ITEM 458 | 1 | Kg. |
459 | 459 | Providing and fixing circular/ hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia140m., 73mm height, bottom and top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron/ box by means of 3.3mm dia.round headed screws, one lock at the corners. Clamp shall be made of 12mm dia.M.S. bar bent to shape as per standard drawing. | ITEM 459 | 1 | Each |
460 | 460 | Providing and fixing hand rail by welding etc.to steel ladder railing,balcony railing & staircase railing including applying apriming coatof approved steel primer GI Pipes 40 mm nominal bore (class B). | ITEM 460 | ||
461 | 461 | 12mm cement plaster of mix 1:6 (1cement : 6 coarse sand). | ITEM 461 | 1 | Sqm. |
462 | 462 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1cement : 6 coarse sand). | ITEM 462 | 1 | Sqm. |
463 | 463 | 6mm cement plaster to ceilling of mix 1:3(1cement: 3 fine sand). | ITEM 463 | 1 | Sqm. |
464 | 464 | 12 mm cement plaster finished with a floating coat of neat cement of mix : \n1:4 (1 cement: 4 fine sand) | ITEM 464 | 1 | sqm |
465 | 465 | Providing and fixing 10 mm thick acid and or/ alkali resistance tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS: 4457, complete as per the direction of enfgineer-in-charge. | ITEM 465 | ||
466 | 466 | a) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement:4 coarse sand) - Acid and alkali resistant tile | ITEM 466 | 1 | sqm |
467 | 467 | b) in dado/skirting on 12 mm thick mortar1:4 (1 acid proof cement: 4 coarse sand) - Acid and alkali resistant tile | ITEM 467 | 1 | sqm |
468 | 468 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement motar 1:4 (1 cement : 4 coarse sand) - 25 mm thick. | ITEM 468 | ||
469 | 469 | Kota stone slab 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement motar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. | ITEM 469 | ||
470 | 470 | Providing and fixing 1st quality wall ceramic glazed wall tiles conforming to IS:15622 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colours, shades except begundy, bottle green , black of any size as approved by Enginner -in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement :3 Coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shades complete. | ITEM 470 | ||
471 | 471 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality confirming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. | ITEM 471 | ||
472 | 472 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate, 20 mm nominal size) in and top layer 12 mm thick cement haedener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This include cost of cement slurry. | ITEM 472 | ||
473 | 473 | Cement Plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement of 18 mm thick. | ITEM 473 | 1 | Sqm. |
474 | 474 | Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with absorption less than 0.08% and confirming to IS:15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete ; size of tile 600x600 mm | ITEM 474 | 1 | Sqm. |
475 | 475 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. | ITEM 475 | 1 | Sqm. |
476 | 476 | Distempering with oil bound washable distemper of approved brand(Asian,Nerolack) and manufacture to give an even shade new work (two or more coats) over and including priming coat with cement primer. | ITEM 476 | 1 | Sqm. |
477 | 477 | Making plinth protection 50 mm thick of cement concrete 1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | ITEM 477 | 1 | sqm |
478 | 478 | Finishing walls with water proofing cement paint "Snowcem - Plus" of M/s Asian, Berger Ltd. or equivalent of required shade:New work (Two or more coats applied @ 3.84 Kg/10 Sqm.) | ITEM 478 | 1 | Sqm. |
479 | 479 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatement of roofs, balconies, terraces etc consisting of following operation: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compund conforming to IS: 2645 and approved by Engineer-in-charge. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand ) admixed with water proofing compund conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. | ITEM 479 | ||
480 | 480 | c) After two days of proper curing applying a second coat of cement slurry using 2.7kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.d) finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 admix with water proofing compound conforming to IS:2645 and approved by Engineer incharge.e)the whole terrace so finished shall be flooded with water for minimum period of 2 weeks for curring and final test. All above operations to be done in order and as directed and specified by the Engineer-in-charge. | ITEM 480 | ||
481 | 481 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (External work) | ITEM 481 | ||
482 | 482 | a) 20 mm dia. nominal bore. | ITEM 482 | ||
483 | 483 | b) 25mm dia. nominal bore. | ITEM 483 | ||
484 | 484 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40mm nominal bore. | ITEM 484 | ||
485 | 485 | Providing and Fixing brass stop cock of approved quality. 15mm nominal bore. | ITEM 485 | ||
486 | 486 | Providing and Fixing C.P.Brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms. | ITEM 486 | ||
487 | 487 | a) 15mm nominal bore. | ITEM 487 | ||
488 | 488 | Providing and Fixing C.P.Brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | ITEM 488 | ||
489 | 489 | a) 15mm nominal bore | ITEM 489 | ||
490 | 490 | Providing and Fixing G.I. Pipes complete with GI.Fittings and clamps, including cutting and making good the walls etc. (internal work). | ITEM 490 | ||
491 | 491 | a) 15mm dia. Nominal bore. | ITEM 491 | ||
492 | 492 | b) 25mm dia nominal bore. | ITEM 492 | ||
493 | 493 | Providing and Fixing gun metal gate value with CI wheel of approved quality (screwed end) 25mm Nominal bore. | ITEM 493 | ||
494 | 494 | Providing and fixing water closet squatting pan (Indian type W.C. Pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, Parryware /Hindware / Seabird / Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous chinaOrissa pattern W.C. pan of size 580 x 440mm with integral type foot rests. | ITEM 494 | ||
495 | 495 | Providing and Fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms (Prayag or equivalent) | ITEM 495 | ||
496 | 496 | Providing and Fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 88gms (Prayag or equivalent) | ITEM 496 | ||
497 | 497 | Providing and Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP Brass screws with concealed fitting arrangement of approved quality colour and make (Prayag or equivalent) 450mm long towel rail with total length of 495mm, 78mm wide and effective hight of 88mm, weighin not less than 170gms. | ITEM 497 | ||
498 | 498 | Providing and Fixing PTMT shelf 440mm long, 124mm width and 36mm height of approved quality, colour and make, weighing not less than 300gms (Prayag or equivalent) | ITEM 498 | ||
499 | 499 | Constructing masonary Chamber 60 x 60 x 75cm inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I.surface box 100mm, Top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement: 5 fine sand : 10 graded stone aggregaten 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. -With F.P.S. bricks. | ITEM 499 | ||
500 | 500 | Constructing masonry chamber 90x90x100 cm, inside with 75 class designation brick work in cement morter 1:4 (1 cement:4 fine sand) for sluice valve, with C.I. surface box 100mm. Top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) neccessary excavation foundation concrete 1:5:10(1 cement:5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S bricks. | ITEM 500 | ||
501 | 501 | Providing and fixing wash basin with C.I./M.S brackets, 15mm C.P brass pillar taps,Kingston / Gem / Techno / Parko, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: Flat back wash basin size 550 x 400mm with single 15mm C.P. brass pillar tap. | ITEM 501 | ||
502 | 502 | Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete. | ITEM 502 | ||
503 | 503 | Providing and fixing soil, waste and vent pipes : 100mm dia. sand cast iron S & S pipe. | ITEM 503 | ||
504 | 504 | Providing and Fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe,40mm dia. | ITEM 504 | ||
505 | 505 | Providing and fixing 100mm sand cast Iron grating for gully trap. | ITEM 505 | ||
506 | 506 | Providing & fixing 100mm S.C.I. trap with 100mm inlet and 100mm outlet. | ITEM 506 | ||
507 | 507 | Providing and fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (1) Single socketed pipes. 110mm diameter. | ITEM 507 | 1 | Mtr. |
508 | 508 | Providing and fixing on wall face unplasticised - P.V.C. moulded fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving10mm gap for thermal expansion. | ITEM 508 | ||
509 | 509 | a) Bend 87.5 degree,110mm bend | ITEM 509 | 1 | Each |
510 | 510 | b) Shoe (plain), 110mm shoe | ITEM 510 | 1 | Each |
511 | 511 | Providing and fixing M.S.holder bat clamps of approved design to C.I. or S.C.I. Rain water pipes embeded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and cost of cutting holes and making good the walls etc. 100mm diameter. | ITEM 511 | 1 | Each |
512 | 512 | Providing and placing on tarrace (at all floor levels) polyethylene water storage tank IS:12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, Star, Lotus or equivalent having valid ISI License). | ITEM 512 | ||
513 | 513 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete – 150 mm dia. | ITEM 513 | ||
514 | 514 | Providing and Fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: | ITEM 514 | ||
515 | 515 | a) 300x10mm | ITEM 515 | 1 | Each |
516 | 516 | b) 250x10 mm | ITEM 516 | 1 | Each |
517 | 517 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required color or shade with necessary screws etc. Complete 125mm. | ITEM 517 | 1 | Each |
518 | 518 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:\n250 x 16 mm | ITEM 518 | 1 | Each |
519 | 519 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side/top/centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc.complete of standard rolled sections, joints mitred and welded and sash bars tenoned and riveted with 15 x 3mm lugs, 10cm long, embedded in cement concrete blocks 15 x 10 x 10cm of 1:3:6 (1cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and apriming coat of approved steel primer excluding the coast of metal beading and other fittings except necessary hinges of pivots complete as per approved design.(sectional weight of only steel members shall be measured for payment). | ITEM 519 | ||
520 | 520 | Providing, laying and jointing glazed SW pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc.complete. 150 mm diameter. | ITEM 520 | ||
521 | 521 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete | ITEM 521 | 1 | Kg |
522 | 522 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. | ITEM 522 | 1 | Kg |
523 | 523 | 9.118 Providing and fixing to existing door frames. | ITEM 523 | ||
524 | 524 | 24 mm thick factory made PVC door shutters made of styles and rails of a\nuPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm)\nwith inbuilt edging on both sides. The styles and rails mitred and joint at the\ncorners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having\nwall thickness 1.0 mm and stainless steel screws. The styles of the shutter\nreinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1\nmm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section\nof size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter\nstyles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled\nwith a uPVC multi-chambered single panel of size not less than 620 mm, having\nover all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels\nrod and fastened with nuts and washers, complete as per\nmanufacturer's specification and direction of Engineer-in-charge. (For W.C.\nand bathroom door shutter). | ITEM 524 | ||
525 | 525 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle\niron and 3 mm M.S. gusset plates at the junctions and corners, all necessary\nfittings complete, including applying a priming coat of approved steel primer.\n10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces | ITEM 525 | 1 | sqm |
526 | 526 | a) Using flats 30x6mm for diagonal braces and central cross piece | ITEM 526 | 1 | sqm |
527 | 527 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced\nGypsum) false ceiling tiles of Size 595x595 mm of approved texture, design\nand patterns having moisture content less than 2%, humidity resistance of\n99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476\n(part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal\nlevel suspended on inter-locking metal T-Grid of hot dipped galvanised iron\nsection of 0.33mm thick (galvanized @ 120 grams per sqm including both\nsides) comprising of main-T runners of size 15x32 mm of length 3000 mm,\ncross - T of size 15x32 mm of length 1200 mm and secondary intermediate\ncross-T of size 15x32 mm of length 600mm to form grid module of size 600 x\n600 mm, suspended from ceiling using galvanised mild steel items (galvanizing\n@ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners,\n6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level\nadjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size\n24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with\nthe help of plastic rawl plugs at 450 mm center to center and 40 mm long dry\nwall wood screws. The work shall be carried out as per specifications, drawing\nand as per directions of the Engineer-in-Charge.\n26.26.1 With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. | ITEM 527 | ||
528 | 528 | For shutters of doors, windows & ventilators including providing and fixing\nhinges/ pivots and making provision for fixing of fittings wherever required\nincluding the cost of EPDM rubber / neoprene gasket required (Fittings shall\nbe paid for separately | ITEM 528 | ||
529 | 529 | a) Anodised aluminium (anodised transparent or dyed to required shade according\nto IS: 1868, Minimum anodic coating of grade AC 15) | ITEM 529 | ||
530 | 530 | b) window | ITEM 530 | 1 | kilogram |
531 | 531 | Providing and fixing glazing in aluminium door, window, ventilator shutters\nand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per\nthe architectural drawings and the directions of engineer-in-charge . (Cost of\naluminium snap beading shall be paid in basic item): | ITEM 531 | ||
532 | 532 | a) With float glass panes of 4.0 mm thickness | ITEM 532 | ||
533 | 533 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and\nclerestory windows using wire gauge with average width of aperture 1.4 mm in\nboth directions with wire of dia 0.63 mm all complete | ITEM 533 | ||
534 | 534 | a) With 12 mm mild steel U beading | ITEM 534 | 1 | sqm |
535 | 535 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | ITEM 535 | 1 | cum |
536 | 536 | Centering and shuttering including strutting, propping etc. and removal of form for all heights Foundations, footings, bases of columns, etc. for mass concrete : | ITEM 536 | 1 | sqm |
537 | 537 | a) Lintels, beams, plinth beams, girders, bressumers and\n cantilevers | ITEM 537 | 1 | sqm |
538 | 538 | b) Suspended floors, roofs, landings, balconies and access\n platform | ITEM 538 | 1 | sqm |
539 | 539 | c) Columns, Pillars, Piers, Abutments, Posts and Struts | ITEM 539 | 1 | sqm |
540 | 540 | pvc pipe for electrical work 25mm dia | ITEM 540 | 1 | rm |
541 | 541 | Schedule E: Supply and execution of Electrical Works (Based on DSR) | ITEM 541 | ||
542 | 542 | Schedule a | ITEM 542 | ||
543 | 543 | WIRING AND DISTRIBUTION BOARDS | ITEM 543 | ||
544 | 544 | LIGHT/FAN/EX.FAN/CALL BELL POINTS | ITEM 544 | ||
545 | 545 | Wiring for light point/fan point/exhaust fan point/call bell point with1.5 sq.mm. FRLS PVC insulated, copper conductor single core cable in surface/recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | ITEM 545 | ||
546 | 546 | a) Group C | ITEM 546 | 1 | Each |
547 | 547 | CIRCUIT WIRING : (FOR LIGHT/FAN /EX.FAN /CALL BELL) | ITEM 547 | ||
548 | 548 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cables in surface/recessed steel conduit as required. | ITEM 548 | ||
549 | 549 | a) 2x 2.5 sq.mm + 1x 2.5 sq.mm earth wire | ITEM 549 | 1 | Meter |
550 | 550 | SUB-MAIN WIRING:- | ITEM 550 | ||
551 | 551 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required. | ITEM 551 | ||
552 | 552 | a) 4x 16 sq.mm + 2 x 16 sq.mm earth wire | ITEM 552 | 1 | Meter |
553 | 553 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. | ITEM 553 | ||
554 | 554 | 2 Pair | ITEM 554 | 1 | meter |
555 | 555 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | ITEM 555 | ||
556 | 556 | 25mm | ITEM 556 | 1 | Meter |
557 | 557 | 32mm | ITEM 557 | 1 | Meter |
558 | 558 | 40mm | ITEM 558 | 1 | Meter |
559 | 559 | 15/16A SWITCH SOCKET OUTLET: | ITEM 559 | ||
560 | 560 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | ITEM 560 | 1 | Each |
561 | 561 | Wiring for light/power plug with 2 x 4 sq.mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 no. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | ITEM 561 | 1 | Meter |
562 | 562 | 5/6 SWITCH SOCKET OUTLETS:- | ITEM 562 | ||
563 | 563 | supplying and fixing following modular switch/socket on the existing modular plate & Switch box including connections but excluding modular plate etc. as required. | ITEM 563 | ||
564 | 564 | a) 5/6 amps switch | ITEM 564 | 1 | Each |
565 | 565 | b) 3 Pin 5/6 amp socket outlet | ITEM 565 | 1 | Each |
566 | 566 | c) 15/16 amps switch | ITEM 566 | 1 | Each |
567 | 567 | d) Telephone socket outlet | ITEM 567 | 1 | Each |
568 | 568 | supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. | ITEM 568 | ||
569 | 569 | a) 6 Module (200 mm X 75 mm) | ITEM 569 | 1 | Each |
570 | 570 | 20 A METAL CLAD SOCKET OUTLETS:- | ITEM 570 | ||
571 | 571 | supplying and fixing 20 amps, 240 volts,SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps ''C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | ITEM 571 | 1 | Each |
572 | 572 | Distribution Boards & MCB:- | ITEM 572 | ||
573 | 573 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, inter connections, powder painted including earthing etc. as required (but without MCB/RCCB/Isolotor). | ITEM 573 | ||
574 | 574 | a) 8 way (4 + 24), Double Door. | ITEM 574 | 1 | Each |
575 | 575 | Supplying and fixing following rating four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc.as required. | ITEM 575 | ||
576 | 576 | a) 63 amps | ITEM 576 | 1 | Each |
577 | 577 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissiong etc as required. | ITEM 577 | ||
578 | 578 | a) Single Pole | ITEM 578 | 1 | Each |
579 | 579 | Installation, testing and commissioning of pre-wired, LED fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | ITEM 579 | 1 | Each |
580 | 580 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | ITEM 580 | 1 | Each |
581 | 581 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with. 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required. | ITEM 581 | 1 | Each |
582 | 582 | Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. | ITEM 582 | 1 | Each |
583 | 583 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required | ITEM 583 | 1 | Each |
584 | 584 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required | ITEM 584 | ||
585 | 585 | a) Above 35 sq. mm and up to 95 sq. mm | ITEM 585 | 1 | Meter |
586 | 586 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required | ITEM 586 | ||
587 | 587 | a) Above 35 sq. mm and up to 95 sq. mm | ITEM 587 | 1 | Meter |
588 | 588 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. | ITEM 588 | ||
589 | 589 | a) Above 35 sq. mm and up to 95 sq. mm | ITEM 589 | 1 | Meter |
590 | 590 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required. | ITEM 590 | ||
591 | 591 | a) 100 mm dia | ITEM 591 | 1 | Meter |
592 | 592 | BRASS COMPRESSION GLAND | ITEM 592 | ||
593 | 593 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | ITEM 593 | ||
594 | 594 | a) 3.5 C x 50 sq. mm (35 mm) | ITEM 594 | 1 | Each |
595 | 595 | EARTHING:- | ITEM 595 | ||
596 | 596 | Earthing with G.I. earth pipe 4.5 metere long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. | ITEM 596 | 1 | set |
597 | 597 | Supplying and laying 25 x 5 mm GI strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) | ITEM 597 | 1 | Meter |
598 | 598 | Providing and fixing 25 mmx 5 mm G.I. strip on surface or in recess for connections etc.as required. | ITEM 598 | 1 | Meter |
599 | 599 | Schedule b | ITEM 599 | ||
600 | 600 | SUPPLY & INSTLLATION OF LIGHT FITTING & FANS:- | ITEM 600 | ||
601 | 601 | Supply and erection of LED recessed mounted down light fitting with LED similar to catalogue no. 32W LED LHEWEBP7UL1W032, Havells make including all accessories, connecting wires, cost conveynence and all taxes etc. complete in all respect . (Make: Phillips,bajaj, CG,Havells) | ITEM 601 | 1 | Each |
602 | 602 | b) Supply of surface mounted ceiling light as per bajaj CAT no. BCSC218 CFL W2EB or equivalent approved make approved equivalent make mentioned in the list of approved make of materials. including 2X18 watt CFL complete in all respects. | ITEM 602 | 1 | Each |
603 | 603 | Supply, installation, testing and commissioning of 230V A. C ceiling fan 1200mm with double ball bearing and suitable capacitor complete with wiring with 1.5 sq.mm FR PVC insulated copper conductor, single/ three core cable as instructed etc. as required. | ITEM 603 | 1 | Each |
604 | 604 | Supply of 12" (305 mm) dia (900 rpm) single phase exhaust fan with frame, louvers & bird screen including hardware for fixing complete in all respect including shutter. | ITEM 604 | 1 | Each |
605 | 605 | Supply, erection, testing and commissioning of LED Street light fitting ,pressure di-cast aluminium housing with suitable cover, suitable to work on 220-240V AC supply with system wattage as under : | ITEM 605 | ||
606 | 606 | a) 60W | ITEM 606 | 1 | Each |
607 | 607 | Supplying, erection, Testing and commissioning of 1.5 T capacity, Window type airconditioner complete with remote control, sweeping arrangement in the cool air outlet category of 3 star ( (Make - Voltas,Model No. - 183 DY) and other accessories and 4 KVA wall mounted Copper model stabilizer of voltage range (90 V to 280 V) (Make - Unitech) . | ITEM 607 | ||
608 | 608 | 1.5 Ton | ITEM 608 | 1 | Each |
609 | 609 | Supplying and laying extra copper refrigerent pipe | ITEM 609 | 1 | Metre |
610 | 610 | Supplying and laying of suitable PVC drinage pipe for indoor unit of AC | ITEM 610 | 1 | Metre |
611 | 611 | (Main Distribution Board) | ITEM 611 | ||
612 | 612 | Supply, erection, testing & commissioning of indoor type Main Distribution Board floor mounting type dust and vermin proof by contstruction of 1.6 mm CRCA sheets with bolted construction powder coated panel as specification below :- | ITEM 612 | 1 | Each |
613 | 613 | Incomer | ITEM 613 | ||
614 | 614 | 100 amps, 25 KA, 4P, MCCB - 1 No. (Thermal release, Rotary Handle) | ITEM 614 | ||
615 | 615 | Spreader Link - 1 Set | ITEM 615 | ||
616 | 616 | RYB Indicating lamps with PF - 1 Set | ITEM 616 | ||
617 | 617 | Multi Function Meter - 1 No. | ITEM 617 | ||
618 | 618 | CT 100/ 5 A - 1 Set | ITEM 618 | ||
619 | 619 | 125 amps 4 P Changeover Switch - 1 No. | ITEM 619 | ||
620 | 620 | Outgoing | ITEM 620 | ||
621 | 621 | 63 amps TPN MCB, C Curve - 2 Nos. | ITEM 621 | ||
622 | 622 | 40 amps TPN MCB, C Curve - 2 Nos. | ITEM 622 | ||
623 | 623 | Busbar Rating | ITEM 623 | ||
624 | 624 | One Set 100 amps TPN, 25 KA for 1 Sec. at Copper busbars with colour coated heat shrinkable PVC sleeves and suitable Size. | ITEM 624 | ||
625 | 625 | Note: MCCB, MCB & Changeover Switch - L&T, Legrand, Siemens approved make. | ITEM 625 | ||
626 | 626 | LT Cable | ITEM 626 | ||
627 | 627 | Supply of 1.1 KV grade LT XLPE cable insulated aluminium conductor armoured cable to IS: 7098 (PT-1) including Testing and commissioning of the cables. | ITEM 627 | ||
628 | 628 | 3.5 C x 50 mm2 | ITEM 628 | 1 | Meter |