Rail India Technical And Econimics Services Ltd-RITES has published Supply , Installation , Testing An Commissioning Of Indoor A Outdoor Gears Of Signalling A Telecommunication System Including Electronic Interlocking System In Connection With Construction Of Railway Siding For Transportation At Of Coal From South East . Submission Date for this Tender is 19-04-2021. Railway Signaling Systems Tenders in Gurgaon Haryana. Bidders can get complete Tender details and download the document.
Name of Work:“Supply, Installation, Testing & Commissioning of Indoor & Outdoor gears of Signalling & Telecommunication system including Electronic Interlocking system in connection with Construction of Railway siding for transportation at of Coal from South eastern Coal fields up to STPP, Khurja, Bulandshahar District (UP). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Schedule-A (Supply Signalling) | ITEM 1 | ||
2 | 2 | Supply of Distributed Electronic Interlocking (Hot Standby) with dual VDU of 55" with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan of In Plant Yard & Dispatch Yard and to suit the signalling plan of stations.\nScope of supply against this item includes all the indoor equipments necessary for successful functioning of distributed EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications .\n1. Microprocessor equipment.\n2. I/O cards with card cage and motherboard.\n3. Power supply cards.\n4. All types of connectors and couplers as required.\n5. Industrial grade Dual VDU of 55" .\n6. Industrial grade PC & monitor of 40"\n7. maintenance VDU of 40" console with Laser printer at panel building.\n8. All types of relays required for interfacing.\n9. ECRs suitable for LED signal lamps.\n10. DC-DC convertors (input voltage 110 V DC and output voltage as required)\n11. All types of indoor wires as required.\n12. All types of indoor terminals and fuses as required except \n terminals for main CTR.\n | ITEM 2 | 1 | System |
3 | 3 | 13. Racks for mounting EI equipments and interfacing relays.\n14. Termination rack for indoor cables.\n15. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.\n16. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. \n17. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. \n18. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three sets. \n19. Ring Earthing and EMI shielding of EI room.\n20. Any other item contractor feels neccessary as per their sysyem.\n21.Completion plan of stations.\n22. Class 'A' type surge protection device protection at each SSI room/goomty, mounting arrangements and accessories necessary to make the EI system functional. \n23. Work place for EI is also provided by the contactor\n | ITEM 3 | ||
4 | 4 | Note:\n1. Supply of Optic Fibre Cable, 60Cx1mm indoor cable, IPS, 24 V point operating relays(QBCA1), KLCR, Main Cable Termination Rack & terminals for Outdoor cables and relay rack for mounting point relays are not included in this item. 2. All the materials, for successful commissioning of system, shall be supplied by the contractor without any extra cost. Variation in Bits and variation in number of routes upto (+) 10% shall have no cost bearing.\n3. For further variation (above 10%) of routes, cost will be recovered on prorata basis for % of routes increased. | ITEM4 | ||
5 | 5 | Spares of O&M | ITEM5 | ||
6 | 6 | Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system at In Plant Yard & Dispatached yard Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. | ITEM6 | 1 | Lot |
7 | 7 | Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded. | ITEM7 | 1 | Nos |
8 | 8 | Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI. \n\n* Above items includes suitable cabinet for storing tools to ensure longer life. | ITEM8 | 1 | Set |
9 | 9 | Supply of Hard & soft copy (6 copies as built ) of following indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: this includes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .The also includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testing copy & 2 copies as costruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIP's and other Misc Drgs as per concerened Rly practice and get its approval from railways,if requiered- \n(i) Signalling Interlocking Plan (as per Rly practice)\n(ii) Selection table, \n(iii) Vital & non-vital I/O Bit Chart, \n(iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. \n(v) Front plate diagram of control/indication panel. \n(vi) Application logic \n(vii) Interface circuit with contact analysis. \n(viii) Equivalent circuit of application logic. \n(ix) Prepration & supply of SWRD (station Working Rule Diagram). \n(x) Prepration & supply of station working Rule. | ITEM9 | 1 | Job |
10 | 10 | Key lock relay with 1 No. K 50 (N) relay to operate on 24V/60V DC, 4F/4B contacts confirming to IRS:S-46, IRS:S 34 & IRS:S 23 (as applicable) and firm's specification. Crank handle keys to be provided with different ward combination for each crank handle group and matching sockets on the point machines. | ITEM10 | 15 | No |
11 | 11 | Relay Rack assembly complete with fixtures for mounting point group relays/'Q' style relays in Relay or EI Hut with all accessories like scaffolding, ladder, runway for indoor cables/wires alongwith mounting arrangement as per drg. No. RITES/SIG/GEN/006A-07. | ITEM11 | 8 | Nos |
12 | 12 | Main cable termination rack complete assembly with hylam sheet , screws, nuts & bolts, scaffolding ladders for cable wires alongwith mounting arrangements etc. as per Drg No.RITES/SIG/GEN/052A-09. | ITEM12 | 5 | Nos |
13 | 13 | Fuse block made of PBT as per Specn.No. IRS-S-75/2006(Rev.2) and Drg.No. SA-23748 (Alt. 4) | ITEM13 | 1800 | Nos |
14 | 14 | Non deteriorating type fuses as per IRS-S-78/92 with latest amendment. Rating 2Amps-65%, 4Amps-25%, 16Amps-10%. | ITEM14 | 1800 | No |
15 | 15 | ARA terminal 6 way, made of PBT as per drawing No. 23756 Alt3 confirming to RDSO specn. No.IRS-S-75/2006 (Rev.2 or latest) with latest amendment | ITEM15 | 1200 | Nos |
16 | 16 | ARA terminal (1 way) made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5). | ITEM16 | 3000 | No |
17 | 17 | Supply & fixing of 2-conductor disconnect terminal block for test & measurem ent front entry suitable upto 2.5 sq mm conductor similar to model No. 280-870 of W AGO make. | ITEM17 | 3000 | No. |
18 | 18 | Supply & fixing of End plate similar to model No 280-371 of W AGO make . | ITEM18 | 500 | No. |
19 | 19 | Supply & fixing of Din 35 Rail of dim ension 35mm x 7.5 mm 1mm thickness unslotted similar to model No 210-229 of WAGO make. | ITEM19 | 400 | No. |
20 | 20 | Supply & fixing of End stop for Din 35 Rail 10mm wide similar to model No 249-117W AGO make. | ITEM20 | 200 | No. |
21 | 21 | Cable unarmoured PVC insulated multi core unseathed with plain annealed copper conductor as per colour coding scheme of Raliways in accordance with Specification No: IRS-S-76/89 with Amendement -2 or latest- 60 C x 1 mm dia. | ITEM21 | 3 | Km |
22 | 22 | SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012, (Ver. 3.0) with latest ammendment alongwith LMLA Battery Bank of 300AH & Battery rack (Configuration based on RDSO dwg. no. SDO/IPS/PI-6L/RE/004 and site specific load requirement, shall be put up to RITES with load calulation sheet and approved by employer/consultant before supply) | ITEM22 | 3 | No. |
23 | 23 | SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012, (Ver 3.0) with latest ammendment alongwith LMLA Battery Bank of 200AH & Battery rack (Configuration based on RDSO dwg. no. SDO/IPS/PI-4L/RE/002 and site specific load requirement, shall be put up to RITES with load calulation sheet shall be approved by employer/consultant before supply) | ITEM23 | 1 | No. |
24 | 24 | DG set 15 KVA, 230 V AC single phase with only Mahindra or Kirlosker or Cummins or crompton or similar quality alternator make , two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 15KVA to IRS-S-69/86 along with sound proof enclosure for DG set as per latest guidelines of Central pollution control board of india. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set for self starting and Iron clad siemens or sony single phase (2 way ON-OFF-ON) changeover switch 63 Apms). Suitable Battery cahrger for charging this battery c) 60 liter diesel tank | ITEM24 | 2 | No. |
25 | 25 | Supply of Automatic change-over unit for change-over between three power supply sources of 63 A/230 volts, single phase with provision of manual bypass arrangement. Drawing shall be got approved by Engineer Incharge. | ITEM25 | 4 | No. |
26 | 26 | Supply & installation of maintenance free single earthing for IPS/DAC Equipment. All the materials required shall be supplied by the contractor including cadmium bronze wire rope for connection between earth electrode and equipment box). | ITEM26 | 20 | Set |
27 | 27 | Supply of Universal Earth leakage detector of 8 channels (AC/DC) as per RDSO/SPN/256/2002 or latest. | ITEM27 | 8 | Each |
28 | 28 | Supply & installation of Data logger with interfacing capability with SSI's to moniter Analog & digital inputs(Minimum 12 analog & 512 digital inputs) & enable for networking for a central place as per speci.no. IRS:S-99/2006 with latest amendments. Required type of modem and SSI protocol converter is also to be supplied. | ITEM28 | 4 | No |
29 | 29 | Supply of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. | ITEM29 | 15 | No. |
30 | 30 | Wooden block counter of size 700 mm x 700 mm W x 900 mm H made of teakwood frame & 10 mm /20 mm thick water proof ply with formica finish on top and all four sides having two compartment inside & two doors on opposite sides. | ITEM30 | 5 | No. |
31 | 31 | Office Chair of continuous arms having cushened seats and rest T.W. Arm rest size 36" x 21" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled "Indian Make". Godrej/Jalaram Make. | ITEM31 | 8 | Nos. |
32 | 32 | Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys. Olive green colour Godrej Make. | ITEM32 | 4 | Nos. |
33 | 33 | Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, Godrej Make. | ITEM33 | 4 | Nos. |
34 | 34 | Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black.The chair has plastic caned seat and back on 25 mmround tubular frame. The base is of pressedsheet metal. Godrej/ Allwyn/ Chandan/ Khira make.Width 700 mm,Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, Colour Grey. | ITEM34 | 4 | Nos. |
35 | 35 | 4 door book case of size 1675x840x308mm Godrej make | ITEM35 | 4 | Nos. |
36 | 36 | Desk type electronic Magento phones as per Spec. No. IRS(S)TC-79/2000 with latest amendments. | ITEM36 | 40 | Nos. |
37 | 37 | Supply & fixing of Fire Extinguisher CO2 Type (capacity 5 Kg) | ITEM37 | 16 | No. |
38 | 38 | Outdoor Supply | ITEM38 | ||
39 | 39 | Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDFH. | ITEM39 | 280 | Nos. |
40 | 40 | PVC Insulated Armoured un-screened, under- ground Railway Signaling copper conductor cable confirming to RDSO Specification no. IRSS- 63/2014 with amendment -4 or latest | ITEM40 | ||
41 | 41 | (a) 2 core x 2.5 sq.mm. | ITEM41 | 6 | Km |
42 | 42 | (b) 6 core x 1.5 sq.mm. | ITEM42 | 15 | Km |
43 | 43 | (c)12 core x 1.5 sq.mm. | ITEM43 | 180 | Km |
44 | 44 | Supply of XLPE Insulated,Single later of Galvanised Steel Strips Armoured un-screened, under- ground Railway power cable having Aluminium conductor confirming to RDSO Specification no. IRS-S-63/2014 with amendment -4 or latest and IS-7098(P-1) latest of size 2c x 70 sq.mm in drum length of 1000 mtrs with +-5% tolerance. | ITEM44 | 3 | Km |
45 | 45 | Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/2005 (Ver. 1) Amndt 1 to 5 or latest amendment having 0.9mm dia. | ITEM45 | 50 | Km. |
46 | 46 | Armoured Optical Fibre cable 24 Fibers as per RDSO specification No. IRS:TC:55-2006 rev. 1 with Amdt. 1.1 | ITEM46 | 35 | Km |
47 | 47 | Cable unarmoured PVC insulated, unseathed with plain annealed high conductivity 650V grade copper conductor as per colour coding scheme of Raliways in 100 meter coils, confirming to RDSO Specification No: IRS-S-76/89 with latest amendment- | ITEM47 | ||
48 | 48 | (i) 16 x 0.2 mm.(Grey) | ITEM48 | 1000 | 100 mtr. Coil |
49 | 49 | (ii) 3 x 0.75 mm. (Red, Green & Black) | ITEM49 | 80 | 100 mtr. Coil |
50 | 50 | (iii) 1x6 sq mm. (multistrand flexible wire) | ITEM50 | 80 | 100 mtr. Coil |
51 | 51 | (iv) 1x10 sq mm. (multistrand flexible wire) | ITEM51 | 100 | 100 mtr. Coil |
52 | 52 | Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight through as RDSO specn. No.IRS: TC 77/2012 (Rev.3.0) with (Amdt.-1 to 3) or latest. | ITEM52 | 50 | Nos. |
53 | 53 | Supply of HDPE telecom duct with outer diameter of 40 and inner diameter of 33 mm permanently lubricated as per Specification no. RDSO/SPN/TC/45/2013, Rev.-2.0 Amdt.-1.0 & 2.0 or TEC GR No.G/CDS 08/02 Nov.2004 with latest amendment as available or latest. HDPE pipe shall be supplied For each Km. of HDPE duct following items are to be supplied alongwith 4 mm dia polypropylene rope of approved quality inside whether required. For each Km. of HDPE duct following items are to be supplied a) End plugs-2 No.b) Cable sealing plugs - 2 Nos.C) Plastic couplers slip fit/push fit type-2 No.d) End plugs to be provided along with drum - 2 No. | ITEM53 | 35 | Km. |
54 | 54 | Supply of Half split double wall corrugated (DWC) pipe of HDPE in 2/3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement. | ITEM54 | ||
55 | 55 | (a) Size : 120 mm outer dia. and 103 mm inner dia. | ITEM55 | 1000 | Mtrs. |
56 | 56 | (b) Size : 200 mm outer dia. and 175 mm inner dia. | ITEM56 | 1200 | Mtrs. |
57 | 57 | Non-Split HDPE DWC pipe Confirming to IS:14930 part-II, with threaded coupler, of following sizes: | ITEM57 | ||
58 | 58 | (a) Size 120mm outer dia and 103 mm inner dia | ITEM58 | 1000 | Mtrs. |
59 | 59 | (b) Size 200mm outer dia and 175 mm inner dia | ITEM59 | 1000 | Mtrs. |
60 | 60 | Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm after laying of cable & refilling the trench by loose soil of 100mm to over cable. | ITEM60 | 250000 | No. |
61 | 61 | Galvanised Iron pipe 100 mm dia `B' class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes) | ITEM61 | 400 | Mtrs. |
62 | 62 | Supply and fixing of FRP cable route marker as per drg. No. RITES/SIG/GEN/048-08. | ITEM62 | 500 | No |
63 | 63 | Colour light signal (2 aspect) complete set as per drg.No.SA - 23003 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :\n(a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81. \n(b) Signal base Cast Iron 140 mm dia. to drg. No. S-2011/M.\n(c) CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.\n(d) Colour Light Signal Unit 2 Aspect complete with out signal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.\n(e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78\n\n | ITEM63 | 28 | Set |
64 | 64 | Colour light signal (3 aspect) complete set as per drg.No.SA23002 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :\n(a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.\n(b) Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M.\n(c) CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.\n(d) Colour Light Signal Unit 3 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23002 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.\n(e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment. | ITEM64 | 4 | set |
65 | 65 | Junction type route indicator 2 way complete without lenses, lamp holders and lamps. to IRS-S-66/84 , amdt.1 ot latest with RDSO drg.No.SA-23402 (Adv.) or latest. | ITEM65 | 1 | No |
66 | 66 | Supply & installation of universal AC/ DC numeric route indicator for 1-19 routes with left & right arm complete with optical sensor, housing w/o mounting pole for use with LED ECR. | ITEM66 | 1 | No |
67 | 67 | OFF set bracket for Colour light signal 140mm outside dia. post with 'U' bolt and nuts as per drg No: SA-23080 (adv.) alt. 1. | ITEM67 | 25 | No |
68 | 68 | Independent Shunt Signal Complete hjaving following items :\n(a) Shunt signal post 90 mm dia 1m long to IRS-S-6/81.\n(b) Shunt signal surface base 90 mm dia drg.No. S-2011.\n(c) Position light shunt signal unit without lamp holder unit, lenses & lamps to RDSO drg.No.SA-23840(adv.) ALT-2. \n(d) 04 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M. | ITEM68 | 39 | set |
69 | 69 | Shunt signal dependent type drg No. SA-23840 (adv.) Alt.-1 and S-23845 (adv.) with offset bracket 3½'' dia. to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders. | ITEM69 | 22 | set |
70 | 70 | Calling on signal unit position light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64. | ITEM70 | 2 | No |
71 | 71 | LED signal lighting unit for Junction Type route indicator conforming to Indian Raiway chromaticallity standards & RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM71 | 9 | No |
72 | 72 | LED signal lighting unit for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM72 | 2 | No |
73 | 73 | Supply of LED Signal Lighting Unit for Main Signals as per RDSO specification No. RDSO/SPN/199/2010 (Rev 1.1) ) or latest | ITEM73 | ||
74 | 74 | (a) For Red aspect | ITEM74 | 31 | No |
75 | 75 | (b) For Yellow aspect | ITEM75 | 26 | No |
76 | 76 | (c) For Green aspect | ITEM76 | 6 | No |
77 | 77 | LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) | ITEM77 | 161 | No |
78 | 78 | Track Circuit | ITEM78 | ||
79 | 79 | Track feed battery charger 110 V AC / 2 - 6 V DC - 5 amp charging rate suitable to charge 1, 2 or 3 cells of 80 AH, to IRS-S-89/93 Amendment-2 or latest. | ITEM79 | 70 | No |
80 | 80 | Track feed variable resistance (with phenolic moulded base) 30ohms to suit RDSO drawing number SA20166/M/adv Alt-1, IRS: S-23. | ITEM80 | 70 | No |
81 | 81 | `B' type choke as per specification No.IRS-S-65/83 Amndt -1 or latest. | ITEM81 | 140 | No. |
82 | 82 | Fibre glass Track Lead Junction Boxes as per Drg. No. RITES/SIG/GEN/42-2008 complete with one way terminal block and 450 mm long, 25mm dia plastic HDPE pipe. termination of signalling cable for the use of track circuit. | ITEM82 | 210 | No. |
83 | 83 | Low Maintenance secondary cell of 80AH. Confirming to RDSO Spec. No. IRS:S88/2004 (A) Amndt.-1 or latest. | ITEM83 | 210 | No |
84 | 84 | Channel Bond pin single groove. Tnned or Zinc coated 7mm dia. As per RDSO specn. No. IRS:S-17/75 with Ammendment 1 for bonding track ckt. Wires. | ITEM84 | 4000 | No. |
85 | 85 | G.I.Bond wire soft 8 SWG for bonding resistance -132 ohm/Km. at 27 deg.C. to IS-279 | ITEM85 | 400 | Kg. |
86 | 86 | Nylon Insulated rail joint complete as per specn.IRS-S-40/84 and RDSO's Drg.No SA-22101 (alt-6) for 52 kg rails /SA-22171 (alt-2) for 60 Kg rails/ SA-22191 (alt-2) for 90R rails comprising of :\na) Channel side plate LH -2 No.\nb) Channel side plate RH -2 No.\nc) End post - 1 No.\nd) Insulating plate. - 4 No.\ne) Bushes - 8 No.\nf) Long fish bolts. - 4 No. | ITEM86 | 40 | No. |
87 | 87 | Relay, AC immune, plug-in type, style ‘QTA2’, neutral track, 9 ohms, 2F.1B contacts, front and back contact metal to carbon, complete with plug board, retaining clips and connectors confirming to BRS-939A, BRS-966 (Appendix F2), IRS-S-34 & IRS-S-23 (as applicable). | ITEM87 | 70 | No. |
88 | 88 | Supply and installation of KLCR box (one box to accommodate 2-6 Nos. of key lock relays) | ITEM88 | 4 | No. |
89 | 89 | Supply and fixing of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. | ITEM89 | 12 | No. |
90 | 90 | Relay AC immune , Plug in type Style QSPA1 Neutral Line Slow to pickup, 24V DC 8F,4B contacts Front and back contactsMetal to Carbon complete with plug board retaining clips and connectors conforming to BRS:933A,IRS-S60 &IRS S23 (as applicable). The interlocking code for this unit shall be ABDEJ | ITEM90 | 70 | No. |
91 | 91 | Relay AC immune, plug in type style QBCA1, DC based point contactor, 24V DC, 2F (HD) 4B contacts, front contacts heavy duty and back contacts metal to carbon complete with plug board, retaning clip and connectors confirming to BRS943, IRS S-34 & IRS S-23 interlocking code BCESK. | ITEM91 | 68 | No. |
92 | 92 | Relay, AC Immune, plug-in type, Style "QNA1K" 24 V/1000 Ohm | ITEM92 | 20 | No. |
93 | 93 | Axle Counter | ITEM93 | ||
94 | 94 | Designing as per SIP & Supply of Multi Section Digital Axle Counter System (MSDAC)\ncomplete system as per RDSO Specification No .RDSO/SPN/176/2013 (Version 3 ) or latest consisting of:-\n1) Central evaluator Unit\n2) SM’s Reset Panel\n3) Field unit along with web detector\n4) Centralised High Voltage DC-DC convertors\n5) Final track clearance relay for each section along with accessories equipped for detection points and track section. | ITEM94 | 55 | DP |
95 | 95 | Tool Kit of MSDAC consisting of the following:-\n1) Portable Data Analyser with Data Analysis software for report\ngeneration & Analysis-1 No.\n2) Pure Sine wave Digital Multimeter Kusam – MECO Make Model\nNo.859CF or equivalent – 1 No.\n3) Dummy Wheel CEL makes – 1No.\n4) Ring Spanner 17-19, 24-26 – 1 No. each\n5) Open end Spanner 17-19, 24-26- 1 No. each\n6) Socket Spanner with handle – 1 no.\n7) Screw Driver No.902 – 1 No.\n8) Screw Drive No.935 – 1 No.\n9) Torque Wrench – 1 No.\n10) Marking jig for drilling – 1 No.\n11) Monitoring Unit- 1No | ITEM95 | 2 | No |
96 | 96 | Block Instrument - Block proving with digital axle counter (BPAC) conforming to Specn. No. IRS: S-105/2012 (Ver.0 or latest) using Universal Fail Safe Block Interface (UFSBI) for Single Line and Double line operation consisting of the following: \na) Universal Fail Safe Block Interface (UFSBI) conforming to Specn. No. IRS: S-104/2012 (Ver.0 or latest) - 2 Nos,\nb) SM Panel (RDSO Drg. No. RDSO/S/32019) with accessories -\nc) Relay rack with double locking & sealing arrangement. Wiring diagram as per RDSO Drg. No. - RDSO/S/32020 - 2 Nos. Relays to be supplied with prewired relay rack QN1 = 44 nos., QL1=4 nos., QNA1=12\nd) Block Telephone RDSO Spn. No. RDSO/SPN/191/2005 = 2 Nos.\n \n | ITEM96 | 2 | Set |
97 | 97 | Electrical point machine, IRS heavy duty non-trailable rotary locking type 143mm throw to operate on 110V DC complete with lock & detector slides and cable termination box as per IRS:S-24/2002 (Amd 1) & IRS-S-37/82 (Amd 3 or latest), Drg. No. S-10910 for motor Assembly Drg. No. S-10800. (One No. tool kit will be supplied for installaton for a group of 08 Nos of point machine) including ground connection | ITEM97 | 68 | No |
98 | 98 | Insulation for gauge tie plate for BG as per IRS-S-40/84 and drg.No.T-10372, T-10368, T-10371 each set comprising of :\na) Insulating plate - 2 No.\nb) Bushes - 6 No.\nc) Washers - 12 No. | ITEM98 | 68 | set |
99 | 99 | Insulation for following & leading P-way stretcher bar for BG as per IRS-S-40/84 & drg.no.10367 10368 & 10371 each set comprising of :\na) Insulating plate - 2 No.\nb) Bushes - 2 No.\nc) Washers - 4 Nos.\n | ITEM99 | 204 | set |
100 | 100 | Insulation for 'P' bracket for point machine as per Rly. design each set comprising of :\na) Channel side plate LH -2 No.\nb) Channel side plate RH -2 No.\nc) Bushes - 4 No.\nd) Washers - 4 No. | ITEM100 | 136 | set |
101 | 101 | Steel Appratus case Full, complete with `E' type lock & keys to drg. No.RITES/SIG/GEN/043-08. The E type lock shall have ward No. 32. | ITEM101 | 90 | No. |
102 | 102 | Key Lock 'E' type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different wards. Inspection by Owner's reprsentative | ITEM102 | 90 | No. |
103 | 103 | MISCELLANEOUS | ITEM103 | ||
104 | 104 | Design, prepearation & supply of Six (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5 microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES) \ni) Cable route plan \nii) Location box details with location wiring diagram \niii) Cable termination details\niv)Cable corage plan \nv) C.T. Rack details\nvi) Track bonding plan \nvii) Cable jointing details\nviii) Signal lighting circuit \nix) Circuit diagram for LC Gate No. \nx) Gate Working Rule with Gate Signal Diagram | ITEM104 | 1 | Station |
105 | 105 | Supply of Goods Warning board/Stop Board: Rectangular board of size 600mmx1000mm with angle iron for fixing. Yellow retroreflective tape on black background. | ITEM105 | 6 | No |
106 | 106 | Various types of markers as | ITEM106 | ||
107 | 107 | (a) P markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'P' shall be written in black. | ITEM107 | 5 | No. |
108 | 108 | (b) C markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'C' shall be written in black. | ITEM108 | 2 | No. |
109 | 109 | (c) Signal number plate as per drawing no. RITES/SIG/GEN46-08 3mm. thick white laminated MS sheet shall be used. Letter shall be written in black on yellow background. | ITEM109 | 97 | No. |
110 | 110 | Supply of hand cuff (universal) locks with key (one key for every 4 locks). | ITEM110 | 60 | No |
111 | 111 | Supply of Jumper PVC unsulated Jumper (Lead wire) 7 strand\n | ITEM111 | 1000 | MTRS |
112 | 112 | Supply, Installation, Testing, Commissioning and Integration of the complete System of Microprocessor Based Networkble Analogue Addressable up to 64 nodes 1 Loop Fire Alaram control Panel With Minimum 320 Character LCD Display the panel should be equipped with sufficient nos. of loop. (As per RDSO Specification No. RDSO SPN217/2016 ver 1.0 or latest). Supply of 06 multi detector, 01 Hooter & Strobe, 01 Analogue Addressable Manual Call Point With infegal short circult isolator, analogue addressable protocol having status LED for alarming & standby mode. Electronically addressed, 01 FRLS armoured cables & power with all accessories for connection of all Fire alarm devices. | ITEM112 | 7 | NOS |
113 | 113 | Supply & installation of Media converter, Media converter 10/100 base Tx to 100 base FX SM following feature AUTO MDI-I/MDI-X copper Ethernet port. Supports single mode fiber Option available at 15 Km to 40 Km. 1310 wavelength supports. SCLC connector. RJ-45 Connector for 10/100 Base-T port LFP allows the fiber failure to be propogated to the copper port. | ITEM113 | 1 | Pair |
114 | 114 | Supply & installation, testing & commissioning of switch (SFP-4 port/Fethernet 24 port) , Switch should have 20 10/100/1000BASE-T port and 4 Combo 10/100/1000 Base-T/SFP ports. Switch should support Internal/ External redundant power supply. 1 SD cardslot/USB allowing the user to store boot image and upload configuration files directly from an SD card/USB. Further more,syslog files can also be conveniently saved toa card.\nSwitch should have minimum 88Gbps Switching capacity and 65 mpps packet forwarding rate. \nSwitch should support true stacking minimum 6 units per stack making all the switches as part of a virtual chassis having two dedicated stacking ports with 40 Gbps stacking bandwidth.\nSwitch should support IEEE802.3az standard whic can reduce the energy consumption of link when no packets are being sent. Should support 16k MAC address entries.\nSwitch should support ARP(RFC 826) and Gratuitois ARP and Proxy ARP(RFC1027).\nShould have support IEEE 802 1Q Vlans, IEEE 802.1v Vlans.\nShould support MAC based Vlans.\nShould support GVRP, Private Vlan, Subnet Vlan, Voice Vlan and QinQ.\nSwitch should have support for below spanning Tree protocol\nStandard:\n802.1D STP.\n802.1w RSTP\n802.1s MSTP\nSwitch should support 802.3ad Link Aggregation control protocol. | ITEM114 | 1 | Nos |
115 | 115 | Provision and establishment of site office (of 220 to 270 Sqm) for use of employer with AC, lights, fans, cubicles, tables/workstations, furniture, desktops/laptops with application software and UPS, printers, network photocopier, land line connection with wi-fi, fridge, stove for making tea etc, water dispenser for dispensing hot and cold water, 3 water kettles of each (5L and 2L), cups and saucers (20 sets), silent DG set of minimum 15 KVA and other facilities for making the office functional and making the office fully functional for use of employer(See special conditions about details, operation and stage payment of this item) - All these facilities and equipment will be property of the contractor at the end of project completion. | ITEM115 | 1 | No |
116 | 116 | Running and maintenance of site office by providing watch and ward (3 persons), paying electricity bills, water bills, providing consumables for making tea, providing internet of at least 10 MBPS, providing / replacing drum and catridges for photo copier, providing stationary, providing canned RO water supply, diesel for genset, operation of genset, AMC of all the gadgets and facilities and other required activities for successful and efficient functioning of office (stationary not included) (See special conditions about details, operation and payment of this item) | ITEM116 | 12 | Months |
117 | 117 | Providing AC Road Vehicle mentioned below for the use of Engineer/Employer as directed by engineer-in-charge. Note: Agency should provide / withdraw vehicle / vehicles on advise of engineer-in-charge. Engineer-in-charge shall advise the requirement (for providing or for withdrawal of vehicle or vehicles 7 days in advance). Vehicles will be required to work upto 4000 Km in a month. (Average Kms of all vehicles in all months shall be upto 4000 Km). Vehicles shall be available on all days for 12 hours a day (except one weekly off) | ITEM117 | ||
118 | 118 | (a) Tavera , Innova or similar (Upto a maximum of 5 vehicles at any time) | ITEM118 | 12 | Vehicle Month |
119 | 119 | (b) Extra for running every additional km over and above 4000 Kms (for Tavera, Innova or Similar) | ITEM119 | 10000 | Per Km |
120 | 120 | Telecom Supply | ITEM120 | ||
121 | 121 | Supply,installation,testing and commisioning of 512 Ports Digital/ISDN and IP ready EPABX System with Attendent Console as per RDSO Spec No SPN/TC/27/2007 Revision 1.0 or Latest, with fully equipped for \n(a) 208 Analog DTMF Extension Ports\n(b) 96 Digital Extension Ports\n(c) 24 Co lines Ports\n(d) 4-Wire E&M Cards for 16 Ports\n(e) 32 Ports SIP IP Gatway that can be used as SIP Trunk or Subscriber.\n(f) 6 Nos PRI Cards | ITEM121 | 1 | System |
122 | 122 | Supply of managed SDH STM-1 ADM conferming to TEC specification no\nGR/SDH-04/03 MAR 2005, with (L1.1) aggregate optical interface, order wire, fully wire and equipped for 21E1 & minimum 4/8 port 10/100Base Telectrical interface (with LCAS and GFP) and upgradeable to full 63E1s with all common cards, DDF and all other accessories, manuals etc., with required software. It shall be equipped with redundant power supply card. It shall support a minimum of 3 Nos. of E3/DS3 in a single card and the selection shall be software configurable. | ITEM122 | 1 | No. |
123 | 123 | Supply & installation of Fibre Distribution Management System, 19" rack mountable for 2x24 fibre OFC with connector, patch cord & pigtails as per specn. No. RDSO/SPN/TC/ 37/2000 (Ver. 3) with latest amendment suitable for termination of 2x24 fibre OFC. | ITEM123 | 1 | No |
124 | 124 | Supply of hardware for NMS as per required specification including one no. Monitor 19" TFT and six nos. flash RAM type pen drive as per the specifications enclosed. NMS for SDH/STM and 2 Mb Mux shall be loaded in this equipment. | ITEM124 | 1 | No. |
125 | 125 | Supply of 2MB programmable primary digital drop insert multiplexer as per RDSO spec. IRS-TC 68/2004 or latest with conference facility and other stipulations of tender documents fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation materials, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support card needed for video conferencing and ISDN. It shall also support NMS operations from local/remote locations.\n\nThe above MUX should be equipped with following circuits.\ni) 2 wire/ 4 wire E & M VF circuits (Minimum 24 nos.)\nii) Subscriber loop circuits (Minimum 2 nos.)\niii) Exchange loop circuits (Minimum 2 nos.)\niv) Minimum 2 x 64Kbps co directional data circuits-3 nos or 64 kbps co directional data circuits - 6 nos.\n | ITEM125 | 1 | No. |
126 | 126 | Supply of 19" covered rack (2.2m height min), vero president/Rittel make or similar with Glass front door complete with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with intergrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. | ITEM126 | 1 | No. |
127 | 127 | Supply maintenance free VRLA secondery cells duly charged of 48V 200 AH and each 2.0 V when fully charged 200 AH capacity alongwith accessories i.e. intersell connectivity links/float, 4 nos. insulators for each cell 24 nos. of cell per set as per RDSO Spcn.IRS/S/88/2004 amendment - 1 revision with latest amendments with cuitble steel/ hylam tray battery rack to install/house batteries. | ITEM127 | 1 | set |
128 | 128 | Suppy of 48V, 50 amps battery charger for telecom use as per No.RDSO/SPCN/TL/23/99 (ver.4) or latest in N+1 configuration i.e. using 3 modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery. It shall be equipped with surge and lightening protection of class `B' and `C' the configuration shall be decided as per site requirement. | ITEM128 | 1 | No. |
129 | 129 | Supply of Optical power meter (Wavelength 1310nm & 1550 nm) user)\nselectable, measuring range: +3dbm to 60dbm. Suitable for measure the optical power meter of all types optical equipment & aplicable for monomode & multimode OFC | ITEM129 | 1 | Nos |
130 | 130 | supply of 50 pair PIJF cable- 63 mm cable | ITEM130 | 2 | Km |
131 | 131 | Supply of CAT-6 cable 10/100/1000Mbps. | ITEM131 | 1 | Km |
132 | 132 | Supply, Installation & commissioning of PVC type Casing -Capping 32mm 2 mtrs each piece , Thickness 1.2 mm | ITEM132 | 1 | Km |
133 | 133 | Supply of Laptop of NMS with configuration of Dell inspiron7560 (Z5615035IN9G) Notebook,(15.6 inch, Core 17/8 GB, Win 10 Home 1TB or higher version). (If model is not available then higher model will be accepted). | ITEM133 | 1 | Nos |
134 | 134 | Supply of lightening and surge arrestors of class B&C suitable for single phase supply in TT network as per amendment 5 of RDSO spec.No . RDSO/SPN/ 165/2004 or Latest and as recommended by RDSO letter No.STS/E / IPS/GENL dated 27.01.06(Amendment 5) | ITEM134 | 4 | Set |
135 | 135 | Supply and installation of 600 pairs MDF along with IPM including wiring from Exchange to MDF | ITEM135 | 1 | Set |
136 | 136 | Supply and installation of Digital Phone as per specification given in Para No 1.1.1 of Cheptor IV | ITEM136 | 6 | No |
137 | 137 | Supply and installation of CLI Push button Telephone Betal or LG or Sony or Panasonic Make as per specification given in Para No 1.1.2 of Cheptor IV | ITEM137 | 10 | No |
138 | 138 | Supply of PSU (Wall mounted 12V, 7AH fully charged, maintenance free valve regulated sealed lead acid stationery battery along with B + charger as per RDSO spec. No. 72/97 (Amd-1) or latest for driving 4W DTMF way station cto equipment complete along with copy of maintenance manual. | ITEM138 | 1 | No. |
139 | 139 | Supply & installationof DP Boxes for 10 Pair. | ITEM139 | 20 | No. |
140 | 140 | Splicing of 24 fibers OFC Cable, measuring of jointing loss, setting of fiber in joint enclousre box and fitting in pre-fabricated Plastocrate OFC jointing pits size 1 x 1 x 0.6 meter and burried in the ground as per Drawing No RDSO/TCDO/COP-21. | ITEM140 | 20 | No. |
141 | 141 | Supply and installation of Electronic Rat Repellant of reputed make working on sonic and ultra sonic frequencies as per instructions of site Engineer. | ITEM141 | 4 | No. |
142 | 142 | COMPLETE Circuit Diagram indoor and outdoor as per raqilway standard | ITEM142 | 4 | JOB |
143 | 143 | Hydrometer, exide make or similar for measuring specific gravity of battery graded acid with mounting stand in location boxes. Consignee inspection under manufacture certificate. | ITEM143 | 4 | No. |
144 | 144 | Battery Tester | ITEM144 | 4 | No. |
145 | 145 | Supply of maintainer's tool kit consisting of items as per list below:-\ni) Insulated Screw Driver 12" (Gedore or Taparia make)-2 No.\nii) Plier electric 8" - 2 Nos\niii) Plier cutting 8" - 2 Nos\niv) Stripper - 1 No.\nv) Nose Plier - 1 No.\nvi) Spanner Set-1 No\nvii) Spanner double ended -1 No \nviii) Hammer Ball piece (medium) - 1 No\nix)Soldering Iron 125 watt-1 No\nx) Soldering Iron 65 watt - 1 No\nxi) Multimeter digital - 1 No.\nxii)Tool Box of 18" size similar to VIP or Alfa make\nxiii) Earth Resistance metwr- 1 No.\n | ITEM145 | 1 | Set |
146 | 146 | Pocket fault locater of OFC to indicate cable point of loss (3-4 Kms. on multi mode & 5-6 Kms. on single mode) of FIS-INC, USA make or equivqlent. | ITEM146 | 1 | No |
147 | 147 | Supply of Automatic fusion splicing machine fully automatic RTC microprocessor controlled (Arc fusion type) with automatic selection of fusion current and warm image processing with video display, heat oven, fibre cleaver, stripping tool, battery backup, sufficient no. of splice protection sleeves and isopropy alcohol to be used for splicing. Make-Fital of latest Model. | ITEM147 | 1 | No |
148 | 148 | Supply of 2 x 24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories of make TVSE R&M model No.1500- L 183- XX or Raychem make model.No.BPEO - Type 1-24F or 2179CS - 24F. | ITEM148 | 7 | No. |
149 | 149 | Supply of Plastocrate pre-fabricated OFC jointing pits size 1 x 1 x 0.6 meter as per technical specification. | ITEM149 | 10 | No. |
150 | 150 | Supply of Fibre Distribution Management System, 19" rack mountable for 2x24 fibre OFC with connector, patch cord & pigtails as per specn. No. RDSO/SPN/TC/ 37/2000 (Ver. 3) with latest amendment suitable for termination of 2x24 fibre OFC. | ITEM150 | 1 | No. |
151 | 151 | Supply of of Optical domain reflectometer (OTDR) | ITEM151 | 1 | No. |
152 | 152 | Supply of Optical fibre tool kit with box of FIS INC USA make Part no. F1-0053 | ITEM152 | 1 | Set |
153 | 153 | Supply of one Quad VF 2T transformer joint assembly of VF transformers 470:470/1120:470 as per IRS TC/76/2000 with ammendment - 1 or latest | ITEM153 | 10 | No. |
154 | 154 | Supply of EC socket box as per RDSO spc. No.IRS: TC-42-87, amendment-1 or latest. | ITEM154 | 20 | No. |
155 | 155 | Supply of 6-pin emergency plug & socket flat type as per RDSO spc.no. IRS:TC-42-87. | ITEM155 | 20 | No. |
156 | 156 | Supply of DTMF 4 wire based Headquarters Equipment for Control circuits as per RDSO spec No.IRS.TC..60/93 (or latest) with power supply unit to suit RDSO Spec No.IRS.TC.72.97 (or latest) | ITEM156 | 1 | No. |
157 | 157 | Supply, installation & commissioning of 4 wire DTMF way station Equipment as per RDSO specification No. IRS:TC:60/93 with Amnd. 4 or latest alongwith compatible way station telephone as per RDSO Spec. No. IRS:TC:38:97 with Amnd. No. 1. Item includes their, installation, testing & commissioning with contractor's all materials required for installation. | ITEM157 | 1 | No. |
158 | 158 | Supply of 4 wire DTMF Control Telephone spec.IRS-TC-38/97 with Amendment-1 or latest Tummala make or similar) | ITEM158 | 2 | No. |
159 | 159 | Desk type electronic Magento phones as per Spec. No. IRS(S)TC-79/2000 with latest amendments.. | ITEM159 | 10 | No |
160 | 160 | Supply, installation & commissioning of Power supply for DTMF equipment/Selective calling telephone to RDO spec. IRS:TC:72:97(or latest) with 12v 7AH battery | ITEM160 | 1 | No. |
161 | 161 | Desk type 2 wire DTMF, 12 way selective calling calling group telephone as per RDSO specification no IRS:TC:80:2000 (Set of 12 telehones) | ITEM161 | 2 | Set |
162 | 162 | 2 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 | ITEM162 | 1 | km |
163 | 163 | 5 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 | ITEM163 | 1 | km |
164 | 164 | 10 pair 0.63 mm Jelly filled Armoured Telephone cable annealed bare copper conductor, solid polyethylene insulated and sheathed as per technical specification GR/CUG-01/03 August- 2003 | ITEM164 | 1 | km |
165 | 165 | Supply of 10 Pair copper conductor size 0.63MM PIJF UG Cable as per RDSO Spec No.IRS TC 41/97 or latest | ITEM165 | 1 | km |
166 | 166 | Supply of Thermo Shrink Jointing Kit For Jointing Underground PIJF Cable as per spec. RDSO/SPN/TC/57/2015 (Rev.1) | ITEM166 | 5 | No. |
167 | 167 | Supply of VHF transreceiver set simplex, 25 watt similar to Motorola model no. GM 338 with suitable antenna attached to 12 feet support pipe and 30M RF cable. This shall also include the Power supply for 25W radio (12V/15Amp) with Sealed maint. Free battery (65AH) and one BNC to VHF adapter. This item shall comply to technical specification para.-16.0. | ITEM167 | 1 | set |
168 | 168 | Supply of VHF mobile transreceiver simplex, 5 watt similar to Motorola model no. GP 328 with rechargeable battery. This will include battery charger, one rechargeable spare battery and two spot frequencies for 5W and 25W radios. (supplier shall obtain spot frequencies from WPC for NTPC). This item shall comply to technical specification para.-16.0. | ITEM168 | 6 | set |
169 | 169 | Supply of true RMS Digital Multimeter (Fluke Make Model -289 or similar) | ITEM169 | 1 | No. |
170 | 170 | Supply of Track hand- Drilling machine with all fixtures and 6 nos. 9/32'' drill bit for track bonding for installation. | ITEM170 | 1 | No |
171 | 171 | Megger (Insulation Tester) with effective measurement range of 0.02 - 20 M ohms, Digital, Motwani make Model D-266. | ITEM171 | 1 | No. |
172 | 172 | Cable Route Locator Kit of C-Scope International UK comprising of cable avoidance tool SVG, Digital Signal generator, Signal Clamp. Accessory, Carry Bag it will comprise of following: (i) ST-CAT 33 XD cable avoidance tool CAT 33 XD: Digital underground cable & pipe location reciever & cable avoidance tool that provide location of metallic cables such as signalling cables, armoured OFC, power cable etc. when used in conjuction with the SGV signal generator, the cable avoidance tool converts to a cable route tracer that route traces metallic U/G pipes & cables. pipe etc, in generator mode. Provides depth of cable being traced. (ii) SGV Digital signal generator for conductivity or inductively injection signal into U/G metallic utility pipe or cable to the traced. | ITEM172 | 1 | No. |
173 | 173 | EXECUTION SIGNALLING | ITEM173 | ||
174 | 174 | Installation, wiring, programming, Bell test,Site acceptance test (SAT), commissioning, Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etc as per Railways practice and All Pre-commissioning tests of EI and other equipments supplied against New Ore Load YArd, as per technical specifications of RDSO and OEM . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor. | ITEM174 | 1 | System |
175 | 175 | Training for O&M Staff | ITEM175 | ||
176 | 176 | Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. 1 of this schedule including provision of hard copies of course modules for each trainee. | ITEM176 | 1 | Man month |
177 | 177 | Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs supplied against item no. - 1 of this schedule including provision of hard copies of course modules for each trainee. | ITEM177 | 1 | Man month |
178 | 178 | Testing and commissioning of complete signalling system integration with outdoor gears ,slotting, etc at the staion as a whole. All artisan staff and labours required for testing and with MACLS work shall be provided by contractorfor for indoor and outdoor work. Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter,etc. shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.It also includes provision of temporaty tents/Huts,arranging lights,Chairs & tables, provision of temorary telphones,snacks/drinking water for NI staff round the clock at site etc as reqired duing the NI period in Railways. | ITEM178 | 1 | LS |
179 | 179 | Termination of all cores of all types of Indoor/outdoor cables (Excluding termination in location boxes and terminations on items coming under item No.1 of Schedule A (Supply )after its laying, on both ends and providing number ferrule on each core. This also includes fixing of ARA terminals/disconnecting type terminal block/ 8 way strip, meggering and preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor. | ITEM179 | 4000 | Core |
180 | 180 | EXECUTION SIGNALLING (RELAY ROOM) | ITEM180 | ||
181 | 181 | Erection of cable termination rack. Clamping of cables, Numbering of cables with engraved aluminium strips, Supply of nuts & bolts, MS clamps & cement for massonary works.This will also include paintng of Cable/core particulars for each trminationwith contractors own paint.The place for erection of Termination Rack shall placed as decided by Site Engineer | ITEM181 | 5 | No |
182 | 182 | Installation of relay rack assembly complete alongwith wall supports, sccaffolding, ladders/runway for cables, relay base plates etc. This includes Fixing of Relays with retaining clips, Fixing of disconnecting type terminals/ARA Terminals, PBT Fuse bases( supplied under Schedle A,) , termination of cable cores/wires, Supply of nuts & bolts, MS clamps & cement for massonary works.:This will also include Painting of Relay description on the front side and back side of the Relays as per instruction of site engineer. | ITEM182 | 8 | No |
183 | 183 | Installation, wiring, testing and commissioning of multi channel earth leakage detector including supply of mounting arrangement. | ITEM183 | 8 | No. |
184 | 184 | Necessary arrangement for manufacture, transportation & installation of station masters console for fixing telephones & other equipments as per instruction of Engineer incharge. This includes : All materials like 25mm thick hylum sheet etc. required for the above including sundry items like bolts & nuts, screws, MS angle / flat shall be supplied by the contractor. | ITEM184 | 1 | Job |
185 | 185 | EXECUTION SIGNALLING (POWER SUPPLY/BATTERIES) | ITEM185 | ||
186 | 186 | Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system, at cabin as per technical specification and instructions given in Installation manual of OEM. Approval for installation drawings shall be obtained from project consultant before installation. This includes supply of all materials required for installation and initial charging of low maintenance Lead-Acid batteries (3 cycles). | ITEM186 | 4 | System |
187 | 187 | Installation of DG set, testing and commissioning. This includes casting of vibration free foundation, installation of ASM panel, outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of ASM panel, laying of cables/wires should be carried out in HD PVC channel/ conduit pipe. This includes cost of all mateials required for installation except DG set and perASM panel. Wires/cables as extant practice on Railways and instruction of Engineer at site. | ITEM187 | 30 | Per KVA |
188 | 188 | Installation,wiring,testing & commissioning of LT power panel with auto change-over at Central Cabin. This includes fixing of power panel.termination of LT cables & fixing of Auto-change-over management and its wiring and supply of MS angle,nuts & bolts etc. | ITEM188 | 4 | Nos. |
189 | 189 | Installation, testing and commissioning of battery charger & maintenance free VRLA cells at station. Note: The rate quoted shall be including the cost of DC bus bar of 48 VDC/ Power wire suitable stand etc., connection of power supply to the equipments. All the wiring shall be done with the suitable gauge of power wires through suitable casing/caping as per the instructions of railway engineers. All the materials required for this item shall be supplied by the contractor. | ITEM189 | 1 | No. |
190 | 190 | Installation, wiring and commissioning of 48 volt battery set fully charged, battery chargers and surge supressor. This includes supply of 51 strand of 0.75 mm each strand paramite battery wires in two colours of appropriate length, connection of power supply to the equipments through suitable casing caping as per the instructions of Engineer incharge of Railway at site. This also includes supply & installation of necessary fuses, provision of teak wood planks stands (to be approved by railway before supply) of suitable size for resting of batteries, battery chargers & ultra isolation transformers. All the material required for installation of this item shall be supplied by the contractor. NOTE- Before installation of Batteries contractor has to ensure that batteries are fully charged. | ITEM190 | 1 | No. |
191 | 191 | EXECUTION SIGNALLING (CABLE LAYING) | ITEM191 | ||
192 | 192 | Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. Wherever several cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. | ITEM192 | 32 | Km |
193 | 193 | Excavation of cable trench of 1.0 m. depth & 300 mm. wide across the track width at level / track/Road crossing platform & refilling after laying DWC/RCC pipe (laying of DWC/RCC pipe shall be paid under separate item of schedule) as per cable route chart & technical specification as per Drg.NO.RITES/SIG/GEN/028-98. This include repairing and plastering of platform/pucca road after cable laying. NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe. | ITEM193 | 1500 | Mtr. |
194 | 194 | NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe. | ITEM194 | ||
195 | 195 | Cutting smoothening of inside surface of chase in concrete or hard rocks having size 80mm depth & 70mm width. This work includes laying & covering of cable laid in the chase with brick (225 x 100x 75 mm) i.e. 9 bricks per meter second class bricks placed & embedded longitudinally & plastered on the top of the bricks as per drg No. RITES/SIG/GEN/025-98. This item includes the cost of bricks, cement & sand etc. | ITEM195 | 600 | Mtr. |
196 | 196 | Filling of cable duct by sieved silver/fine sand after laying of cable in relay rooms. Supply of sand shall be made by the contractor. | ITEM196 | 50 | Cum. |
197 | 197 | Fixing/ laying of DWC/RCC pipes for laying of cables (including under-neath the track, Road crossing or other platform cutting etc.) as per drg.No. RITES/SIG/GEN/028-98 & RITES/SIG/GEN/031-98. | ITEM197 | 4200 | Mtr. |
198 | 198 | Fixing of Galvanised iron pipe 100 mm dia. on panel buildings. This includes supply of clamps, support, nuts, bolts etc. & concreting of ends with brick masonary work including supply of cement, sand an aggregate. | ITEM198 | 400 | Mtr. |
199 | 199 | Laying of 40/33 mm dia HDPE pipe as per approved cable route plan in the excavation trench at 1 mtr depth. | ITEM199 | 35 | Km |
200 | 200 | Transportation of cables in roll with or without wooden drums to work site and meggering before loading and after laying, and recording the values in cable insulation register along with representative. | ITEM200 | 300 | Drums/Rolls |
201 | 201 | Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid . | ITEM201 | 289 | Km. |
202 | 202 | Providing Heat Shrinkable joint for all type of S&T cable with contractor's all materials. | ITEM202 | 30 | No. |
203 | 203 | All the materials required for the work are to be arranged by the contradtor himself at his own cost except Thermoshrinkable jointing kit which is already covered in Supply portion of the tender.After jointing the cable through test such as insulation test,Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should redo the joint free of cost. | ITEM203 | ||
204 | 204 | EXECUTION SIGNALLING (POINT MACHINE) | ITEM204 | ||
205 | 205 | Installation, wiring, testing and commissioning of 110 V, DC point machine as per specifications and approved wiring diagrams. This includes:\n(i) Fixing of point machines on MS plate fixed on sleepers complete with fixing of anti theft covers, cable terminal box, ground connection.\n(ii) Fixing of insulation for gauge tie plate and crossing plate for 52 / 60 Kg. points and crossings.\n(iii)Fixing of insulation for switch extention pieces (D brackets) and leading & following stretcher bars.\n(iv) Wiring from the cable termination box to the point machine as per specifications.\n(v) All smithy works.\n(vi) Supply of MS plates, flat, angle, bolts, nuts, pins as required.This item also includess supply & fixing of GI pipe bend for the protection of cable from cable termination box to piont machine.\n(vii) Testing the point machines from point of operation including testing with 5 mm test piece. | ITEM205 | 68 | No |
206 | 206 | P-way works required before provision of point machines such as .squaring of switches, packing and leveling/alignment of track,easing or rails on either side of points to be interlocked,making proper spacing of sleepers etc | ITEM206 | 68 | Job |
207 | 207 | Fabrication, supply and erection of name plate for point machine as per Drg. No. RITES/S&T/ROU/PMNP-01 and as per instruction of Site Engineer. This includes supply of MS Plate (Size: 350mm x 250mm, 3mm thick), MS Angle (Size: 25mm x 25mm, 3mm thick), Cement, Sand, Aggregate, Paint and all other material required for this work. All the smithy mechanical and electrical work/arrangement shall be done by the contractor at his own cost. Point Number shall be written in black on yellow background in 150mm height on both side of the plate. | ITEM207 | 68 | No. |
208 | 208 | EXECUTION SIGNALLING (TRACK CIRCUIT) | ITEM208 | ||
209 | 209 | Fixing & wiring of track circuit equipment such as battery chargers, track feed resistance, `B' type choke, relays batteries etc. as per approved wiring diagram in location box. This includes :- \n(i)Supply, fabrication & fixing of duly varnish teakwood planks of 25 mm thick. \n(ii)Supply of fixing material. | ITEM209 | 70 | No. |
210 | 210 | Installation, wiring, testing & commissioning of DC track circuits as per approved standard practice. This includes :\na) Installation of all types of lead wires, jumpers and rail head continuity bonds ,insulation joints using contractors own consumables & pin brazing machine \nb) Fixing of track lead junction boxes as per drg. No. RITES/SIG/GEN/039-2007. This also includes painting of TLJB.\nc) Charging of track Batteries, Energising the track circuit and testing with 0.5 ohms train shunt resistance. | ITEM210 | ||
211 | 211 | (i) On straight portion of track | ITEM211 | 14 | No. |
212 | 212 | (ii)On point and crossing portion of track | ITEM212 | 54 | No. |
213 | 213 | EXECUTION SIGNALLING (AXLE COUNTER) | ITEM213 | ||
214 | 214 | Intallation, programming, Testing along Commissioning of Central Evaluators of MSDAC (includes & OEM certification), wiring from CT rack to the Central Evaluator, Installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories, with their own material. Note: 1. Variation in detection points and/or track sections upto (+) 10% shall have no cost bearing. 2. Installation of detection points and line side electronics box is not included in this item. | ITEM214 | 55 | DP |
215 | 215 | Installation, Testing & Commissioning of track device (double rail contact) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to track side housing and making its terminations. Termination of 4Quad cable in track side electronic box. Fixing of deflector plates. (Double walled antirodent corrugated pipe made up of high density polyethylene of required diameter and all other accessories as per site requirement to be supplied by the firm & installation of EJB/ Track side electronic box inside the track side housing, including supply of wires and other accessories. | ITEM215 | 55 | No |
216 | 216 | P-way work required for provision of Axle counter track detection devices to be fixed on rails including work involving re-spacing of sleepers, packing of sleepers etc | ITEM216 | 55 | DP |
217 | 217 | Installation, wiring, testing and commissioning of Block Instrument - Block proving by Axle Counter (BPAC) along with Universal Fail Safe Block Interface (UFSBI). This includes supply of all the materials (which are not covered in supply schedule) required for the job . | ITEM217 | 2 | Pair |
218 | 218 | EXECUTION SIGNALLING (COLOUR LIGHT SIGNALS) | ITEM218 | ||
219 | 219 | Excavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per drg.No.RITES/SIG/GEN/001 -98. This includes : Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM219 | 32 | No. |
220 | 220 | Erection of 2 aspect colour light signals.This includes :\n(i) Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity. \n(ii)Wiring & testing of signal unit as per the specifications and directives of engineer at site. | ITEM220 | 28 | No. |
221 | 221 | Erection of 3 aspect colour light signals.This includes :\n(i) Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity. \n(ii) Wiring & testing of signal unit as per the specifications and directives of engineer at site. | ITEM221 | 4 | No |
222 | 222 | Testing & commissioning of 2 /3/4aspect colour light signals. | ITEM222 | 32 | No |
223 | 223 | Excavation of pit, casting & plastering of concrete foundation for shunt signal. As per Drg. No.RITES/SIG/ GEN/002-98. This includes : Supply of foundation nuts & Bolts, cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM223 | 39 | No |
224 | 224 | Erection of shunt signal. This includes :\na). Erection of surface base, shunt signal post, shunt signal unit.\nb). Fixing of hoods and LED lamps with regulating transformer.\nc). Termination of the tail cable in the signal unit.\nd). Wiring of shunt signal unit with wiring material.\ne) Necessary arrangement of material to be used by bidder own arrangement. | ITEM224 | 39 | No. |
225 | 225 | Installation of shunting limits boards/Goods warning board/stop board as per standard practice at site. The necessary materials like cement, concrete and sand etc., for the installation of these boards shall be supplied by contractor. | ITEM225 | 6 | No |
226 | 226 | EXECUTION SIGNALLING (APPARATUS CASE) | ITEM226 | ||
227 | 227 | Excavation of pit, casting of concrete foundations for full location box as per Drg.No.RITES/SIG/GEN /003-09 This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6. | ITEM227 | 90 | No. |
228 | 228 | Erection of full location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This includes - \n(i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc.\n(ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of ables with contractors own material\n(iii). Filling up pit inside the location box by sand and plastering on the top of the sand.\n(iv). Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams. | ITEM228 | 90 | No |
229 | 229 | Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signal unit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98, RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes:\n(i) Diging of pit in earth 3 m deep.\n(ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98.\n(iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal.\n(iv) Connecting the equipment through earth lead wire & soldering.\n(v) Supply of cement, wiring material & soldering material.\n | ITEM229 | 240 | No. |
230 | 230 | EXECUTION SIGNALLING (PAINTING) | ITEM230 | ||
231 | 231 | Painting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint. | ITEM231 | ||
232 | 232 | (i) Full case | ITEM232 | 90 | No |
233 | 233 | Painting of Main signal post with signal unit, surface base complete with route indicator, dependent shunt, calling On unit, ladder fittings as per Indian.Rlys. standard practice. | ITEM233 | 32 | No |
234 | 234 | Painting of two coats of enamel paint black Asian and Aiuminium white as approved by Site engineer over one coat of primer on Shunt signal unit , base and post | ITEM234 | 61 | No |
235 | 235 | Painting of two coats of enamel paint black Asian and red oxide as approved by Site engineer over one coat of primer on point machine and ground connection respectively | ITEM235 | 68 | No |
236 | 236 | Installation and commissioning of 25W radio at station building. This includes erection of power supply unit and antenna with support pipe. | ITEM236 | 1 | Set |
237 | 237 | Necessary arrangement of material, installation & commissionig of Pre-wired Crank Handle cum key lock relay box along with LEDs, TEKNIC make push buttons, 8-way terminal strips, string rod etc. as per instructions of Engineer at site. | ITEM237 | 15 | No. |
238 | 238 | Cement concrete work for miscellaneous items with supply of cement, sand, stone chips and mixing in the ratio 1:3:6. This item includes excavation, raming, curing and plastering with cement & sand mixture (stone chips size not exceeding 40mm). | ITEM238 | 50 | Cu.Mtr |
239 | 239 | Providing brick massonary in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor's own IInd nd class bricks including excavation curing, grouting,bolting etc. Whereever required bricks sand and cement to be supplied by the contractor. | ITEM239 | 50 | Cu.Mtr |
240 | 240 | Foundation & fixing all types of cranks & A type foundation | ITEM240 | 15 | No. |
241 | 241 | Fabrication of EC socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer-in-charge. | ITEM241 | 20 | Nos |
242 | 242 | Excavation of jointing pit and provision of joint chamber of 1.2 mter dia. Of 60 cm height with 2 piece cover on top and bottom cover with holes for drainage (reinforcement drawing will be as per technical specification). This includes water cooling of chamber, backfilling and ramming of the trench after cable laying and consolidation of soil as well as disposal of soil as per plan advised by site engineer. | ITEM242 | 20 | Nos. |
243 | 243 | Painting of emergency socket assembly and rail post by applying one coat of red oxide as base colour and then painting the assembly as per zebra painting in white and block colours. The width of each of the black and white colours shall be 100mm. All paints used shall be with ISI mark. | ITEM243 | 20 | Nos |
244 | 244 | Manual horizontal auger boring/drilling of 100mm dia Horizontal Bore across the Railway Track/Across Road at LC gates by boring method at a depth of 1.65 mm from the ground level/ground level to be considered ignoring the bank height of the bank/load and insertion of GI pipes etc. as per the instructions engineer in charge at site as per drg. no. RAIL TEL/SR. OFC/2008/10. | ITEM244 | 800 | Mtr. |
245 | 245 | Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn/laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of item no. (6h) of this schedule. OFC and HDPE pipe shall be supplied by the railway. | ITEM245 | 35 | KM |
246 | 246 | Installation of fiber distribution management system with contractor's own installation material, splicing and termination of 2x24 fiber OFC, routing dressing fibers as per instructions of Engineer incharge. | ITEM246 | 1 | No |
247 | 247 | Installation, testing and commisioning of NMS including uploading of STM/PD MUX.All the required fixing hardware material will be arrenged by contractor free of cost. | ITEM247 | 1 | No |
248 | 248 | Installation and wiring of SDH / STMs and PD Mux supplied with all accessories, DDF with miniature ‘U’ link type for 63 E1s, runway ladder etc in already installed 42-U Euro rack. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH with all interface cards to the 48V Bus including supply of wires and connectors, termination of all E1s on DDF. This includes all the sundry material required for installation. | ITEM248 | 1 | No |
249 | 249 | Supply and installation of Optical Fiber termination box as per spec No. DPG/G/FIB-01/02 Mar 99 or DOT/G/FTB-01, Jan 93 or with latest amendment and splicing of all the fibers inside the termination box with provision of taking out OFC as required. This includes supply of all installation acccessories required to complete th installation as per spec No. G/OFJ-01/03 June 99 with latest amendment 10 mtr long patch cord as per spec. No. G/OJF-01/01 with connector as per code of practice for installation and commissioning of OFC. | ITEM249 | 1 | No |
250 | 250 | Installation, of 19" 42 U Rack with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with intergrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack.configuration shall be decided as per site requirement.All required fixing hardware material will be arrenged by contractor free of cost. | ITEM250 | 1 | No |