| Name of Work: CONSTRUCTION OF NEW BUILDING (BASEMENT+4 STOREY) IN GOVT. SR. SEC. SCHOOL, AT NAWANSHAHAR IN DISTT SHAHEED BHAGAT SINGH NAGAR | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Construction of School Buildings (Basement+4 Storey) Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 1462.38 | Cum. |
| 2 | 2 | Disposal of Malba outside the premises loading / unloading including all leads as desired by Engineer in charge . | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 1322.36 | Cum. |
| 3 | 3 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. | 219.72 | Cum | |
| 4 | 4 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 549.29 | Cum. | |
| 5 | 5 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth\n- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. | 343.12 | ltr | |
| 6 | 6 | Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type | 56.27 | Cum. | |
| 7 | 7 | Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. | 347.17 | Cum | |
| 8 | 8 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 325.13 | sqm | |
| 9 | 9 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. | 14.19 | Cum | |
| 10 | 10 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. Lintels | 10.77 | Cum | |
| 11 | 11 | Extra rate for First Floor | 2.55 | Cum | |
| 12 | 12 | Extra rate for Second Floor | 2.57 | Cum | |
| 13 | 13 | Extra rate for Second Floor | 2.86 | Cum | |
| 14 | 14 | Extra rate for Fourth Floor | 0.17 | Cum | |
| 15 | 15 | Shelves | 2.67 | Cum | |
| 16 | 16 | Total all Floor Extra rate for First Floor | 0.8 | Cum | |
| 17 | 17 | Extra rate for Second Floor | 0.28 | Cum | |
| 18 | 18 | Extra rate for Third Floor | 0.28 | Cum | |
| 19 | 19 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture Beams | 180.55 | cum | |
| 20 | 20 | Extra rate for First Floor | 41.53 | Cum | |
| 21 | 21 | Extra rate for Second Floor | 41.53 | Cum | |
| 22 | 22 | Extra rate for Third Floor | 23.44 | Cum | |
| 23 | 23 | Extra rate for Fourth Floor | 1.82 | Cum | |
| 24 | 24 | Columns (Rectangular & Square) | 89.6 | Cum | |
| 25 | 25 | Total all Floor Extra rate for First Floor | 23.03 | Cum | |
| 26 | 26 | Extra rate for Second Floor | 23.03 | Cum | |
| 27 | 27 | Extra rate for Third Floor | 18.64 | Cum | |
| 28 | 28 | Extra rate for Fourth Floor | 1.87 | Cum | |
| 29 | 29 | Walls | 27.35 | Cum | |
| 30 | 30 | Total all Floor Extra rate for First Floor | 6.96 | Cum | |
| 31 | 31 | Extra rate for Second Floor | 6.96 | Cum | |
| 32 | 32 | Extra rate for Third Floor | 6.47 | Cum | |
| 33 | 33 | Slab | 370.72 | Cum | |
| 34 | 34 | Total qty for all floor Extra rate for First Floor | 80.52 | Cum | |
| 35 | 35 | Extra rate for Second Floor | 80.52 | Cum | |
| 36 | 36 | Extra rate for Third Floor | 34.43 | Cum | |
| 37 | 37 | Fascia | 2.41 | Cum | |
| 38 | 38 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. | 3046.54 | sqm | |
| 39 | 39 | Total qty for all floor Extra rate for First Floor | 652.03 | Sqm | |
| 40 | 40 | Extra rate for Second Floor | 642.41 | Sqm | |
| 41 | 41 | Extra rate for Third Floor | 275.2 | Sqm | |
| 42 | 42 | Extra rate for Fourth Floor | 33.91 | Sqm | |
| 43 | 43 | Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain) | 716.8 | Sqm | |
| 44 | 44 | Total qty for all floor Extra rate for First Floor | 184.24 | Sqm. | |
| 45 | 45 | Extra rate for Second Floor | 184.24 | Sqm. | |
| 46 | 46 | Extra rate for Third Floor | 149.12 | Sqm. | |
| 47 | 47 | Extra rate for Fourth Floor | 14.96 | Sqm. | |
| 48 | 48 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels | 1530.56 | Sqm | |
| 49 | 49 | Total qty for all floor Extra rate for First Floor | 352.64 | Sqm. | |
| 50 | 50 | Extra rate for Second Floor | 352.8 | Sqm. | |
| 51 | 51 | Extra rate for Third Floor | 210.4 | Sqm. | |
| 52 | 52 | Extra rate for Fourth Floor | 15.92 | Sqm. | |
| 53 | 53 | Centring and shuttering for stair cases with sloping with\nsoffits including risers and stringers. | 122.27 | Sqm. | |
| 54 | 54 | Total qty for all floor Extra rate for First Floor | 27.06 | Sqm | |
| 55 | 55 | Extra rate for Second Floor | 27.06 | Sqm | |
| 56 | 56 | Extra rate for Third Floor | 14.03 | Sqm | |
| 57 | 57 | Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc | 1569.1 | Sqm | |
| 58 | 58 | Total qty for all floor Extra rate for First Floor | 90.48 | Sqm | |
| 59 | 59 | Extra rate for Second Floor | 90.48 | Sqm | |
| 60 | 60 | Extra rate for Third Floor | 84.11 | Sqm | |
| 61 | 61 | Centring and shuttering for carbels, parapet, fascias and other similar items including edges. | 48.2 | Sqm | |
| 62 | 62 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. | 578.26 | Cum | |
| 63 | 63 | Total qty for all floor Extra rate for First Floor | 88.53 | Cum. | |
| 64 | 64 | Extra rate for Second Floor | 239.11 | Cum. | |
| 65 | 65 | Extra rate for Third Floor | 99.61 | Cum. | |
| 66 | 66 | Extra rate for Fourth Floor | 37.9 | Cum. | |
| 67 | 67 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. | 168.16 | Sqm | |
| 68 | 68 | Total Qty for all floor Extra rate for First Floor | 53.44 | Sqm | |
| 69 | 69 | Extra rate for Second Floor | 68.64 | Sqm | |
| 70 | 70 | Extra rate for Third Floor | 23.04 | Sqm | |
| 71 | 71 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx\nwith 35mm wide single rebate | 433.56 | Rmt | |
| 72 | 72 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm\nexceeding 0.4 sqm of area Float glass panes of 5.5 mm thickness | 13.94 | sqm | |
| 73 | 73 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. | 28.86 | Qtl | |
| 74 | 74 | Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. | 2886 | kg | |
| 75 | 75 | 12.5mm thick cement plaster 1:5. | 1776.84 | Sqm. | |
| 76 | 76 | Extra rate for Basement | 276.79 | Sqm. | |
| 77 | 77 | Extra rate for First Floor | 384.16 | Sqm. | |
| 78 | 78 | Extra rate for Second Floor | 409.03 | Sqm. | |
| 79 | 79 | Extra rate for Third Floor | 283.51 | Sqm. | |
| 80 | 80 | Extra rate for Fourth Floor | 22.05 | Sqm. | |
| 81 | 81 | 20 mm thick cement plaster 1:5 in two coats work. | 1776.84 | Sqm | |
| 82 | 82 | Extra rate for Basement | 276.79 | Sqm. | |
| 83 | 83 | Extra rate for First Floor | 384.16 | Sqm | |
| 84 | 84 | Extra rate for Second Floor | 409.03 | Sqm | |
| 85 | 85 | Extra rate for Third Floor | 283.51 | Sqm | |
| 86 | 86 | Extra rate for Fourth Floor | 22.05 | Sqm | |
| 87 | 87 | 12.5 mm thick cement plaster 1:4. | 1202.39 | Sqm. | |
| 88 | 88 | Extra rate for Basement | 216.28 | Sqm. | |
| 89 | 89 | Extra rate for First Floor | 187.6 | Sqm. | |
| 90 | 90 | Extra rate for Second Floor | 206.4 | Sqm. | |
| 91 | 91 | Extra rate for Third Floor | 183.01 | Sqm. | |
| 92 | 92 | Extra rate for Fourth Floor | 169.03 | Sqm. | |
| 93 | 93 | 20 mm thick cement plaster 1:4. | 1202.39 | Sqm | |
| 94 | 94 | Extra rate for Basement | 216.28 | Sqm | |
| 95 | 95 | Extra rate for First Floor | 187.6 | Sqm | |
| 96 | 96 | Extra rate for Second Floor | 206.4 | Sqm | |
| 97 | 97 | Extra rate for Third Floor | 183.01 | Sqm | |
| 98 | 98 | Extra rate for Fourth Floor | 169.03 | Sqm | |
| 99 | 99 | Extra rate for Smooth Surface of Ceiling. | 2153.41 | sqm | |
| 100 | 100 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp\nU-PVC pipes (working pressure 4kgf. / sqcm)\npipe 110 mm dia. | 265.7 | Rmt. | |
| 101 | 101 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.\nUPVC 110 mm bend | 21 | Nos. | |
| 102 | 102 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. | 21 | Nos. | |
| 103 | 103 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. | 15 | Nos. | |
| 104 | 104 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. | 21 | Nos. | |
| 105 | 105 | Providing and fixing in position gratings 150mm x 150mm for gully trap.\nPVC grating | 15 | Nos. | |
| 106 | 106 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing Third Floor | 233.53 | Sqm. | |
| 107 | 107 | Total qty for all floor Extra rate for Second Floor | 233.53 | Sqm. | |
| 108 | 108 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. | 90.37 | Rmt | |
| 109 | 109 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. \nUsing Rough Kota Stone Basement | 624.65 | sqm | |
| 110 | 110 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge Using Rough Kota Stone | 503.74 | Sqm. | |
| 111 | 111 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 503.74 | Sqm. | |
| 112 | 112 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material Basement | 551.34 | Sqm. | |
| 113 | 113 | Ground Floor | 31.66 | Sqm. | |
| 114 | 114 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material | 1049.07 | Sqm. | |
| 115 | 115 | Total qty for all floor Extra rate for First Floor | 441.35 | Sqm. | |
| 116 | 116 | Extra rate for Second Floor | 440.42 | Sqm. | |
| 117 | 117 | Extra rate for Third Floor | 145 | Sqm. | |
| 118 | 118 | Extra rate for Fourth Floor | 22.3 | Sqm. | |
| 119 | 119 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. | 54.7 | Sqm. | |
| 120 | 120 | Extra rate for First Floor | 13.64 | Sqm. | |
| 121 | 121 | Extra rate for Second Floor | 6.04 | Sqm. | |
| 122 | 122 | Extra rate for Third Floor | 6.04 | Sqm. | |
| 123 | 123 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. | 1527.05 | Sqm. | |
| 124 | 124 | Total Qty for all Floor Extra rate for First Floor | 383.33 | Sqm. | |
| 125 | 125 | Extra rate for Second Floor | 359.51 | Sqm. | |
| 126 | 126 | Extra rate for Third Floor | 344.39 | Sqm. | |
| 127 | 127 | Extra rate for Fourth Floor | 20.07 | Sqm. | |
| 128 | 128 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing | 248.95 | Sqm. | |
| 129 | 129 | Extra rate for First Floor | 60.22 | Sqm. | |
| 130 | 130 | Extra rate for Second Floor | 60.71 | Sqm. | |
| 131 | 131 | Extra rate for Third Floor | 24.79 | Sqm. | |
| 132 | 132 | Extra rate for Fourth Floor | 1.98 | Sqm. | |
| 133 | 133 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. | 529.04 | Sqm. | |
| 134 | 134 | Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings. | 37.16 | Sqm. | |
| 135 | 135 | Extra labour for projected nosing of stair case of any shape and design | 383.76 | rmt | |
| 136 | 136 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. | 1696.8 | Rmt | |
| 137 | 137 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)\nSize 600x600 mm | 138.12 | sqm | |
| 138 | 138 | Total Qty for all floor Extra rate for First Floor | 23.8 | Sqm. | |
| 139 | 139 | Extra rate for Second Floor | 47.35 | Sqm. | |
| 140 | 140 | Extra rate for Third Floor | 43.41 | Sqm. | |
| 141 | 141 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. | 138.12 | sqm | |
| 142 | 142 | Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.70 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect. | 82.29 | Rmt. | |
| 143 | 143 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. | 30.42 | sqm | |
| 144 | 144 | Total Qty for all floor Extra rate for First Floor | 10.14 | Sqm. | |
| 145 | 145 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. | 164.05 | Kg | |
| 146 | 146 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). | 34.49 | Sqm. | |
| 147 | 147 | Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. Third Floor | 36.18 | sqm | |
| 148 | 148 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. | 283.93 | sqm | |
| 149 | 149 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion & Chaukhat | 1913.11 | kg | |
| 150 | 150 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required | 1914.9 | kg | |
| 151 | 151 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) | 191.49 | sqm | |
| 152 | 152 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider.& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non star bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. | 34.18 | sqm | |
| 153 | 153 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop | 3828.01 | Kg | |
| 154 | 154 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position \n(Code : IS 2202-1) (1999)\nCommercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-\n35mm thick | 106.29 | Sqm | |
| 155 | 155 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)\nFor shutter area above 0.50 sqm | 316.59 | Sqm | |
| 156 | 156 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :\n300mm x 16mm | 51 | Nos | |
| 157 | 157 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 10mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for stiles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the stiles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. | 18.81 | Sqm | |
| 158 | 158 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-\nAbove 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position. | 81.4 | Qtl | |
| 159 | 159 | Corrugated GI Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, GI Limpot and bitumen washers complete excluding the cost of purling rafters and trusses. | 289.6 | Sqm. | |
| 160 | 160 | GI Sheet gutters 0.80mm thick semicircluar 15cm diametre including fixing with clamps and making connections with rain water pipes. | 18.63 | rmt | |
| 161 | 161 | Providing & laying foam concrete cement : coarse sand 1:4 using admixer mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator including reinforcemed with 2\" x 2\"x 2.5mm thick M.S wire mesh duly fixed with | 29.38 | cum | |
| 162 | 162 | Providing and laying an Atatic plypropylene modified bituminous reinforced water proofing membrance system, thickness 3mm (Make: Sika WP Shield 103P) with plain finish laying on priming coat of solvent based bituminous primer (Make: Sika WP Shield primer) @ 0.40kg/sqm including preparation of surface complete as per specification and as desired by Engineer-in-Charge. | 289.6 | Sqm. | |
| 163 | 163 | Providing and Fixing writing Boards made of Ply Board with sunmica finishing partly white partly green, Aluminium frame, Back side PVC water proof sheet duly fixed at site complete as per drawing & entire satisfaction of Engineer-in-Charge. | 14 | nos | |
| 164 | 164 | Providing & Installation of Lab Tabel in Chemistary / Home Scence Size of Table 13.50x3'-0\" complete as per architect drawing | 8 | nos | |
| 165 | 165 | Providing & Installation of lab Tabel in Zoology Lab. / Home Science Lab, / Lab. Size of Table 13'x3 complete as per architect drawing | 4 | nos | |
| 166 | 166 | Providing & Installation of Lab Tabel in Chemistary / Zology / Botony Lab. Size of DomonstiationTable 5.50*2.25 complete as per architect drawing | 3 | nos | |
| 167 | 167 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete | 1040.88 | qtl | |
| 168 | 168 | Total Qty for All Floor Extra rate for First Floor | 168.47 | qtl | |
| 169 | 169 | Extra rate for Second Floor | 168.18 | qtl | |
| 170 | 170 | Extra rate for Third Floor | 97.57 | qtl | |
| 171 | 171 | Extra rate for Fourth Floor | 9 | qtl | |
| 172 | 172 | Extra rate for using steel produced by primary producer complete in all respect as per the directions of Engineer-in-charge. | 1040.88 | Qtl. | |
| 173 | 173 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish | 4972.28 | Sqm | |
| 174 | 174 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade | 5153.5 | Sqm | |
| 175 | 175 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. | 75.25 | Sqm | |
| 176 | 176 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. | 239.15 | Sqm | |
| 177 | 177 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. | 239.15 | Sqm | |
| 178 | 178 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. | 314.4 | Sqm | |
| 179 | 179 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm | 1972.2 | Sqm | |
| 180 | 180 | Construction of Plinth protection complete as per drawing. Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 21.03 | Cum. | |
| 181 | 181 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type | 8.41 | Cum. | |
| 182 | 182 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. | 30.28 | Cum. | |
| 183 | 183 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 66.26 | Sqm. | |
| 184 | 184 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). | 99.39 | Sqm. | |
| 185 | 185 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. | 66.26 | Sqm. | |
| 186 | 186 | B Outer infrastructure Construction of Parking/pavement & Footpath Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications. | 169.8 | Cum. | |
| 187 | 187 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type | 118.68 | Cum. | |
| 188 | 188 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 5.93 | sqm | |
| 189 | 189 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications | 14.15 | cum | |
| 190 | 190 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.\nIS COde : 15658 (2006) | 686.3 | sqm | |
| 191 | 191 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. | 137.26 | sqm | |
| 192 | 192 | Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications | 115.82 | rmt. | |
| 193 | 193 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 79.43 | sqm | |
| 194 | 194 | Providing and laying 50 mm thick factory made cement concrete interlocking paver block of M-30 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge\nIS COde : 15658 (2006) | 79.43 | sqm | |
| 195 | 195 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. | 15.89 | sqm | |
| 196 | 196 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior sufrace | 52.12 | sqm | |
| 197 | 197 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. \n | 52.12 | sqm | |
| 198 | 198 | PUBLIC HEALTH SERVICES Sub Work-1 Internal Water Supply, Sewerage, Sanitation Sub Head-1 Internal Sewerage System Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.\nSingle Socket Type A 110mm o/d single socket SWR UPVC pipe lines laid complete | 106.37 | mtr | |
| 199 | 199 | 75mm o/d single socket SWR UPVC pipe lines laid complete | 156.35 | mtr | |
| 200 | 200 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm i/d pipes Elbow 90 Degree (All side socketed) | 15 | Nos | |
| 201 | 201 | Vent Cowls | 3 | Nos | |
| 202 | 202 | Coupler | 19 | Nos | |
| 203 | 203 | Single Tee With Door | 9 | Nos | |
| 204 | 204 | For 75mm i/d pipes Elbow 90 degree (all side socket)\n | 5 | Nos | |
| 205 | 205 | Vent Cowls | 5 | Nos | |
| 206 | 206 | Coupler | 30 | Nos | |
| 207 | 207 | Single Tee With Door | 16 | Nos | |
| 208 | 208 | Floor Trap 110mm x 75mm | 36 | Nos | |
| 209 | 209 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. M.S. Holder bats clamps for 100mm i/d | 24 | Nos | |
| 210 | 210 | M.S. Holder bats clamps for 75mm i/d | 40 | Nos | |
| 211 | 211 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm | 7 | Nos | |
| 212 | 212 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal | 7 | Nos | |
| 213 | 213 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 6 Kgf/cm250mm i/d | 4.57 | mtr | |
| 214 | 214 | Total Sub Head-1:- Sub Head-2 Internal Water Supply System CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 16mm o/d | 18.29 | mtr | |
| 215 | 215 | SDR 11 CPVC pipes & fittings 20mm o/d | 21.03 | mtr | |
| 216 | 216 | CPVC SDR 11 Pipe & fitting 25mm o/d | 60.96 | mtr | |
| 217 | 217 | CPVC SDR 11 Pipe & fitting 40mm o/d | 39.62 | mtr | |
| 218 | 218 | CPVC SDR 11 Pipe & fitting 50mm o/d | 15.24 | mtr | |
| 219 | 219 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 80mm i/d Vertical in Ducts | 100 | mtr | |
| 220 | 220 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. \nSize 75mm x 75mmqty same as GI P 15mm i/d to 25 mm | 100.28 | mtr | |
| 221 | 221 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through wall 11.43 cm thick | 24 | nos | |
| 222 | 222 | Through wall 22.86 cm thick | 24 | nos | |
| 223 | 223 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.15mm i/d G.I. Union | 8 | Each | |
| 224 | 224 | 20mm i/d G.I. Union | 8 | Each | |
| 225 | 225 | 25mm i/d G.I. Union | 12 | Each | |
| 226 | 226 | 40mm i/d G.I. Union | 6 | Each | |
| 227 | 227 | 50mm i/d G.I. Union | 6 | Each | |
| 228 | 228 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. 25mm i/d Brass Ball valves | 12 | Each | |
| 229 | 229 | 40mm i/d Brass Ball valves | 12 | Each | |
| 230 | 230 | 50mm i/d Brass Ball valves | 12 | Each | |
| 231 | 231 | Sub Head - 3 Sanitary Installation Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. | 12 | Nos | |
| 232 | 232 | Providing and fixing jet spray with 2'-6\" long PVC pipe.With PTMT nut | 12 | Nos | |
| 233 | 233 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. | 12 | Nos | |
| 234 | 234 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. | 8 | Nos | |
| 235 | 235 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 49 cm dia (above counter round) | 24 | Nos | |
| 236 | 236 | Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineer-in-charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. Size 470mmx370mmx180mm\n | 24 | Nos | |
| 237 | 237 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. \nPVC tube connection of size 15 mm x 375 mm with PTMT nut | 96 | nos | |
| 238 | 238 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. | 48 | nos | |
| 239 | 239 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. | 8 | Nos | |
| 240 | 240 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body without flange | 8 | Nos | |
| 241 | 241 | C.P Brass bib cock foam flow without flange | 12 | Nos | |
| 242 | 242 | Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect (instead of Pillar tap in Lavatory Suites). | 24 | Nos | |
| 243 | 243 | Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect.\n Laboratory cock swan neck One Way\n | 24 | Nos | |
| 244 | 244 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange | 72 | Nos | |
| 245 | 245 | C.P.brass 15mm Concealed stop cock with flange | 12 | Nos | |
| 246 | 246 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. | 104 | each | |
| 247 | 247 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.\nC.P. Brass extension piece, 25mm long to 50mm long | 104 | each | |
| 248 | 248 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) | 24 | Nos | |
| 249 | 249 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.\nC.P. Brass khunti with 3 pegs | 12 | Nos | |
| 250 | 250 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. \nDouble Layer Tanks | 10000 | ltr | |
| 251 | 251 | Providing and fixing in position automatic brass Ball Cock in tanks.\nBrass Ball Cock with rod and Plastic Ball \nBrass Ball Cock with rod and Plastic Ball \n32mm i/d | 3 | Nos | |
| 252 | 252 | Brass Ball Cock with rod and Plastic Ball \n25mm i/d | 4 | Nos | |
| 253 | 253 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d | 7 | Nos | |
| 254 | 254 | G.I. tank nipple 40mm i/d | 7 | Nos | |
| 255 | 255 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank | 3 | Nos | |
| 256 | 256 | For 500 & 1000 ltr Water Tank | 4 | Nos | |
| 257 | 257 | Total Sub Head-3:- Sub Head-4 Flooring and Wall Tile Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 14.73 | Sqm. | |
| 258 | 258 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping. | 44.19 | sqm | |
| 259 | 259 | Extra rate for First Floor | 14.73 | sqm | |
| 260 | 260 | Extra rate for Second Floor | 14.73 | sqm | |
| 261 | 261 | Extra rate for Third Floor | 14.73 | sqm | |
| 262 | 262 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . | 44.19 | sqm | |
| 263 | 263 | Extra rate for First Floor | 14.73 | sqm | |
| 264 | 264 | Extra rate for Second Floor | 14.73 | sqm | |
| 265 | 265 | Extra rate for Third Floor | 14.73 | sqm | |
| 266 | 266 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 48.6 | sqm | |
| 267 | 267 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. | 271.65 | sqm | |
| 268 | 268 | Extra Rate for First Floor | 90.55 | sqm | |
| 269 | 269 | Extra rate for Second Floor | 90.55 | sqm | |
| 270 | 270 | Extra rate for Third Floor | 90.55 | sqm | |
| 271 | 271 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. | 10.02 | sqm | |
| 272 | 272 | Extra Rate for First Floor | 3.34 | sqm | |
| 273 | 273 | Extra rate for Second Floor | 3.34 | sqm | |
| 274 | 274 | Extra rate for Third Floor | 3.34 | sqm | |
| 275 | 275 | Extra labour for projected nosing of stair case of any shape and design | 29.26 | rmt | |
| 276 | 276 | Sub Head -5 Water Coller Providing & fixing in position Water Cooler\nwithout Stablizer of approved make (to the\napproval of Engineer-in-charge ) including\ncarriage complete in all respect.\n Water Cooler Semi Steel Body 80/120 ltr\nCapacity without Stablizer | 1 | nos | |
| 277 | 277 | Water Cooler Full Steel Body 40/80 ltr\nCapacity without Stablizer | 3 | Nos | |
| 278 | 278 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-\nAutomatic Voltage Stablizer 2 KVA | 4 | Each | |
| 279 | 279 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. | 4 | Nos | |
| 280 | 280 | D1 INTERNAL ELECTRICAL SERVICES Providing Internal Electrical Installations RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:- \n Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-\nMake :- PVC Pipe = Anchor, Polycab, Norpack, Adarh Plast, Diplast. PVC Copper Wires = Polycab, Bonton, Gemscab, KEI, Grandlay, Ultracab, RR kabel, , Havell's, L&T, Batra Henlay,. .\nAccessories:-North-West (Nova), Havell's (Crab Tree), Hager(Insysta),Anchor (Roma Plus),Polycab(Levana),L&T(Entice),Goldmedal(Nixon)\nWiring fan point with sheet metal fan box | 94 | Each | |
| 281 | 281 | Wiring light point | 254 | Each | |
| 282 | 282 | Wiring call-bell point Wiring 3 pin 6 Amp. wall socket point | 80 | Each | |
| 283 | 283 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point | 4 | Each | |
| 284 | 284 | Wiring 3 pin 16/20 amp. power plug control point | 8 | Each | |
| 285 | 285 | Wiring light point with double control switches. | 20 | Each | |
| 286 | 286 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:\nSupply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- PVC Copper Wires = Polycab, Bonton, Gemscab, KEI, Grandlay, Ultracab, RR kabel, , Havell's, L&T, Batra Henlay,. Overall size 1sq.mm (Un-sheathed) | 1500 | Mtr. | |
| 287 | 287 | Overall size 2.5sq.mm (Un-sheathed) | 250 | Mtr. | |
| 288 | 288 | Overall size 4sq.mm (Un-sheathed) | 500 | Mtr. | |
| 289 | 289 | Overall size 10sq.mm (Un-sheathed) | 850 | Mtr. | |
| 290 | 290 | Overall size 16sq.mm (Un-sheathed) | 100 | Mtr. | |
| 291 | 291 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):-\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Make:-Bonton,Polycab,Gemscab, KEI, Grandlay, Ultracab, RR kabel, Havell's.Overall size 70sq.mm (3½ Core) Un-armoured (Loose)\n | 200 | mtr. | |
| 292 | 292 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):-\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Make:-Bonton,Polycab,Gemscab, KEI, Grandlay, Ultracab, RR kabel, Havell's. Overall size 4sq.mm (3Core) Armoured (On-Surface) (For Flood Lights) | 200 | mtr. | |
| 293 | 293 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-\nMake:- Anchor, Polycab, Norpack, Adarh Plast, Diplast. Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed | 200 | Mtr. | |
| 294 | 294 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed | 230 | Mtr. | |
| 295 | 295 | Supply and erection of PVC flexible pipe complete without compression glands,locking arrangement, check-nuts as required:- PVC flexible pipe 40mm dia. | 50 | Mtr. | |
| 296 | 296 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- PVC compression Socket gland 40mm dia. | 12 | Each | |
| 297 | 297 | HEAVY GUAGE WELDED CONDUIT PIPES:\nSupply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. | 120 | Mtr. | |
| 298 | 298 | COPPER EARTHING :-\n(Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-\n Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) | 2 | Each | |
| 299 | 299 | Additional Length 20mm x 3mm thick Copper Tape . | 20 | mtr | |
| 300 | 300 | MINIATURE CIRCUIT BREAKERS:-\nSupply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- \nGROUP-A: Siemens (Beta Guard), Legrand (Lexic) , Schneider (Acti-9), L&T (Exora),Hager MCB Single Pole 6-32amp. (10kA, Curve-C) | 78 | Each | |
| 301 | 301 | MCB Double Pole 40amp. (10kA, Curve-C) | 1 | Each | |
| 302 | 302 | MCB Four Pole 40amp. (10kA, Curve-C) | 4 | Each | |
| 303 | 303 | MCB Triple Pole 50,63amp. (10kA, Curve-C) | 6 | Each | |
| 304 | 304 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:\nSupply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-\nMake:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER\nSP&N Horizontal Double Door Distribution Board 8 way each. | 1 | Each | |
| 305 | 305 | TP&N Horizontal Double Door Distribution Board 6 way each. | 4 | Each | |
| 306 | 306 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-Make:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGERTP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp) | 1 | Each | |
| 307 | 307 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- Cable End Box for SPN 8 Way | 1 | Each | |
| 308 | 308 | Cable End Box for TPN 6 Way | 4 | Each | |
| 309 | 309 | Cable End Box for TPN Vertical 4/8/12Way | 1 | Each | |
| 310 | 310 | SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):- Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses (Suitable for DIN HRC Fuses) in sheet enclosure on the existing surface Confirms to IS 13947 (Part-III), IEC 60947-3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:- SDF TP&N 32Amp., 415volts (With Sheet Enclosure) | 1 | No | |
| 311 | 311 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):-\nSupply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-Make:- HPL / L&T / C&S On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure) | 1 | Each | |
| 312 | 312 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):-\nDesigning, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).\nFabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. \nThe door should be double folded without edge and the gasket should be ‘S’ type puffed neutraineutraindal proof with a Clear opening of 800/900mm (Wide) x 2000mm (High). * Door operation : Automatic DC Door operation with Adjustale door opening and Closing timings. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . \nBusbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. \nMetering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. \nManufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO certified (Manufacturer workshop ISndal proof with a clear opening 800/900mm (wide)*2000mm (HIgh) * door operation. Automatic DC door operation with Adjustable door opening and closing timing. Manufacutrer panel should be CPRI apporved (Approval not older than 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.\nDetail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- I LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) | 1 | Each | |
| 313 | 313 | MOULDED CASE CIRCUIT BREAKERS:\nSupply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc\n Make: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting | 4 | Each | |
| 314 | 314 | MCCB Four Pole 160amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting | 1 | Each | |
| 315 | 315 | MOULDED CASE CIRCUIT BREAKERS:\nSupply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.\nMake: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting | 1 | Each | |
| 316 | 316 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including\nexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-\nMake :-TeleRex,Gemni,CPE,Dura Line Double walled corrugated (DWC) HDPE pipe 50/38mm (outer/ inner dia.) | 50 | mtr | |
| 317 | 317 | Double walled corrugated (DWC) HDPE pipe90/76mm (outer/ inner dia.) | 150 | mtr | |
| 318 | 318 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make: Jaquar LGLZ01X020XC / Philips BN02IC LED20S PSU CW GR/ Havells ENDURALINEARNEOBS20WLED830SPCWH, Crompton:-LDL-20-CDL, C&S:-LTTB4F20WLED/W | 44 | Each | |
| 319 | 319 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- BAJAJ Cat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILLIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH | 179 | Each | |
| 320 | 320 | Supply and erection of Recessed mounted 36watt LED panel(including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per circular issued by Hon. Tech. Advisor to CM Punjab Letter no ATBP/20/CL Dated 30/09/2017. Make:- PhilipsRC380B LED36S -6500 G4 L60 W60 PSD OD WH OC /jaquar LULTO1SO36XC/CROMPTON :-LCTLRNE-36-FO-CDL (2X2),WIPRO:- LM25-361-XXX-65-G1/ C&S :- LTCRP36WLED2X2 | 25 | Each | |
| 321 | 321 | Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with louver shutter ,double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make:- Crompton EXHD300-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty . | 26 | Each | |
| 322 | 322 | Supply and erection of Ceiling Fan 1200mm , (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton Entrust 50Opel White/ Havell's ES-50/ ANCHOR:-Panta Turbo Star code 13671WH / V-Guard Coolgate 48, Halonix:- Zephyr(ISI ) | 94 | Each | |
| 323 | 323 | Supply and erection of LED Flood Light 120watt (including LED driver),Pressure Die cast aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- Jaquar LFLDO2S0120XC/ Philips BVP122 LED 124 CW HE AK55° FG XTFCL S4 / Crompton :-LFLN-120-CDL/60-M/ WIPRO:- LF20-132-060-57-G2. | 8 | Each | |
| 324 | 324 | D2 Providing Advance Lightning Protection System Supply,Erection,Testing & Commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct LIGHTNING point as well conducting /diverting it to earth completely after tracing the LIGHTNING in advance.As per NF C 17-102:2011 the air terminal should be tested for LIGHTNING impulse current (10/350 micro sec)=100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 107mtr High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast.\nMake:- JMV / LPI / Escoltrix | 1 | Nos | |
| 325 | 325 | Supply and fixing of GI Mast 5 mtr height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector / Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conductor, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required. | 1 | Nos | |
| 326 | 326 | Supply and Installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system.This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures.It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs above the ground level. | 1 | Nos | |
| 327 | 327 | Supply & erection of Test Link of non-corroding,weather proof,water proof polycarbonate IP 65/55 enclosure including providing of 2 nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire.The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor | 1 | Nos | |
| 328 | 328 | Supply, Installation & Testing of Chemical Earthing (Maintenance Free Earthing) System with UL Approved Copper Bonded Rod and exothermically welded Cu Busbar both tested by CPRI at 50kA Fault Current. A Copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper bonding thickness of minimum 250 microns. Along with Earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A Copper clad steel solid ground wire of 8 mm dia. For interconnecting earth pits including earth pit covers is required.Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber.The grounding minerals should not be pollute the ground water.The grounding minerals shall be tested & certified for the resistivity of less than 0.12ohm mtr. \nMake:- JMV / AI- ( Amiable Impex ) / Growth | 3 | Nos | |
| 329 | 329 | Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge. | 4 | Nos | |
| 330 | 330 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:\nSupply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- PVC Copper Wires = TAMRA,KEI,RR KABEL,RALLISON, HAVELLS,L&T, V-GUARD,CMI,GREATWHITE SECUREX,GOLDMEDAL,KUNTHCAB.Overall size 70sq.mm (Un-sheathed) (as down conductor to connect the air terminal and erthing) | 60 | Mtr. | |
| 331 | 331 | D3 Providing LIFT (13Passenger ) *Design, manufacture, supply, installation, testing and commissioning of 1 Nos. Lift of 13 Passengers (Deep) Machine Room Less.\n*Type and Capacity : Approximately 884 Kg , 13 Passengers (deep) \n*Speed:1.00 mps\n*Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. \n*Motor: Geared Machine to be Placed on the Shaft in machine room\n*Travel: Approximately 18 meter________ \n*Serving: 5 Floors _5 Stops 5 Openings 5 Levels (All on the same side) \n*Hoist way Required : 2050mm (Wide) x 2500mm (Deep) Clear dimensions \n*Headroom Height (HR): 5000 mm beyond finished floor level of last landing \n*Pit Depth : 1600mm below the finish floor level of first landing \n*Car Size Area: Minimum 2.06 square meter and Maximum 2.20square meter \n*Car Enclosure : Constructed out of stainless steel Scratch proof Finish (Vandal Proof).\n*Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800/900mm (wide) x 2000mm (high) \n*Door operation : Automatic DC Door operation with adjustable door opening and closing timings \n*Control: Simplex full selective collective control with and without attentdent \n*Operation: Automatic \n*Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current \n*Flooring: PVC/Vinyl Tiels (Floor Skid - Resistant as per standard )\n*Fan: Blower Fan in Car for ventilation with Auto cut off \n*Lighting: LED for Car Lighting \n*Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings \n*Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) \n*Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level \n*Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level \n*Free service Two Year after the S/I/T/C work and all std. Govt. features. \n Other Features : \n1. Battery operated emergency light with rechargeable battery \n2. Battery operated emergency alarm with rechargeable battery \n3. Adjustable Guide shoes \n4. Micro movement LED based buttons \n5. Door Open and Close buttons \n6. Emergency Intercom provided inside the elevator \n7. Emergency Intercom usable without the voice communication \n8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication \n9. Steel items, door frames sill angle's, fascia plates, spring buffers\n10. Automatic phase reversal device and Phase Failure protection\n11. Call registration \n12. Audio & Video System installted in the lift indicating arrival at a floor \n13. Manual break lever \n14. Additional car gate lock \n15. Automatic break testing infrared safety curten \n16. Braille Buttons (Inside and outside) with Braille instructions for the communication system \n17. Kick plate/Skirting \n18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is . either Open or Close \n19. Car Operating Panel \n20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel \n21. Phase two device fire man drive \n22. Fire Man switch at main lobby \n23. Car false ceiling in stainless steel \n24. Pit ladder \n25. Anti Nuisance car call protection \n26. Door Nudging, Mirror an rear will of hall car height \n27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.\nMake:- OTIS/ THYSSEN KRUPP/KONE | 1 | Each | |
| 332 | 332 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-\nMake:-Bonton,Polycab,Gemscab, KEI, Grandlay, Ultracab, RR kabel, Havell's.Overall size 16sq.mm (4Core) Un-armoured (On-Surface) | 10 | mtr. | |
| 333 | 333 | XLPE INSULATED ARMOURED CABLES (LOOSE):\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-\nMake:-Bonton,Polycab,Gemscab, KEI, Grandlay, Ultracab, RR kabel, Havell's. Overall size 16sq.mm (4Core) Armoured (Loose) | 20 | mtr. | |
| 334 | 334 | COPPER EARTHING :-\n(8 SWG COPPER EARTHING :):-Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long | 2 | Each | |
| 335 | 335 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) | 20 | mtr | |
| 336 | 336 | MOULDED CASE CIRCUIT BREAKERS:\nSupply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.\nMake: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,LegrandMCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting | 2 | Each | |
| 337 | 337 | MS SHEET ENCLOSURE FOR MCCB's:\nSupply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- \n\nMS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) | 2 | Each |