Power Development Department has published Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2021-22. Submission Date for this Tender is 10-04-2021. Bolts Tenders in SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: Rate Contract of Supply of different materials for upkeep and maintenance of distribution system for the year 2021-22 | |||||
---|---|---|---|---|---|
Sl.No | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply of : | |||
2 | 1.01 | 11 KV link Set (Post type) Heavy duty. Suitable for 400-630 Amp current capacity. (IS: 9920 (Part-I to IV)) | item1 | 1 | Set |
3 | 1.02 | 11 KV Air break switch with pipe & handle complete (3 phase, 600 Amp) (IS: 9920 (Part-I to IV)) | item2 | 1 | Set |
4 | 1.03 | 11 KV Drop Out Fuse Set 3 Phase 400A (IS:9385 (Part-I to III) as amended upto date) | item3 | 1 | Set |
5 | 1.04 | Gapless Surge Arrestor, 9 KV, 10 KV, LA with (polymer/porcelain) housing, Stn. Type (IS: 3070 Part-3) | item4 | 1 | Set |
6 | 1.05 | 11 KV Pin insulator with pins 12 KN. (IS:731 and IS:3188) | item5 | 1 | No |
7 | 1.06 | LT Shackle Insulators with Mukki Clamps (16 KN) of Standard Make | item6 | 1 | No |
8 | 1.07 | Galvanised Nuts and Bolts of sizes. 6”,7”,8”,9”,11”,12”x1/2” dia half thread. | item7 | 1 | Kg |
9 | 1.08 | G.I wire 8 SWG. | item8 | 1 | Kg |
10 | 1.09 | Guy wire 7/14 SWG. | item9 | 1 | Kg |
11 | 1.1 | Guy rods with turn buckle 5’ long complete | item10 | 1 | Set |
12 | 1.11 | 11 KV tension disc/suspension Disc (IS:731 and IS:3188) | item11 | 1 | Set |
13 | 1.12 | Fabricated GI channel, X-arms of sizes (75x40x6) mm (50x50x6)mm and (100x50x6) mm. | item12 | 1 | Kg |
14 | 1.13 | Fabricated GI Angle, (50x50x6mm) | item13 | 1 | Kg |
15 | 1.14 | Al. Solderless clamps suitable for transformer1000 KVA as per relevant IS | item14 | 1 | No |
16 | 1.15 | Al. Solderless clamps suitable for transformer630 KVA as per relevant IS | item15 | 1 | No |
17 | 1.16 | Al. Solderless clamps suitable for transformer400/500 KVA as per relevant IS | item16 | 1 | No |
18 | 1.17 | Al. Solderless clamps suitable for transformer250 KVA as per relevant IS | item17 | 1 | No |
19 | 1.18 | Al. Solderless clamps suitable for transformer100 KVA as per relevant IS | item18 | 1 | No |
20 | 1.19 | Al. Solderless clamps suitable for transformer63 KVA as per relevant IS | item19 | 1 | No |
21 | 1.2 | Aluminium Thimbles 630 mm2 as per relevant IS | item20 | 1 | No |
22 | 1.21 | Aluminium Thimbles 500 mm2 as per relevant IS | item21 | 1 | No |
23 | 1.22 | Aluminium Thimbles 400 mm2 as per relevant IS | item22 | 1 | No |
24 | 1.23 | Aluminium Thimbles 300 mm2 as per relevant IS | item23 | 1 | No |
25 | 1.24 | Aluminium Thimbles 240 mm2 as per relevant IS | item24 | 1 | No |
26 | 1.25 | Aluminium Thimbles 185 mm2 as per relevant IS | item25 | 1 | No |
27 | 1.26 | Aluminium Thimbles 120 mm2 as per relevant IS | item26 | 1 | No |
28 | 1.27 | Aluminium Thimbles 95 mm2 as per relevant IS | item27 | 1 | No |
29 | 1.28 | Aluminium Thimbles 70 mm2 as per relevant IS | item28 | 1 | No |
30 | 1.29 | Aluminium Thimbles 35 mm2 as per relevant IS | item29 | 1 | No |
31 | 1.3 | Aluminium Thimbles 25 mm2 as per relevant IS | item30 | 1 | No |
32 | 1.31 | Aluminium Thimbles 16 mm2 as per relevant IS | item31 | 1 | No |
33 | 1.32 | 35 mm sq, 11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster | item32 | 1 | Mtr |
34 | 1.33 | 50 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster | item33 | 1 | Mtr |
35 | 1.34 | 70 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster | item34 | 1 | Mtr |
36 | 1.35 | 95 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster | item35 | 1 | Mtr |
37 | 1.36 | 120 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster | item36 | 1 | Mtr |
38 | 1.37 | 16 mm2 Single Phase Cable 1.1 KV Grade, XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item37 | 1 | Mtr |
39 | 1.38 | 25 mm2 Single Phase Cable 1.1 KV Grade, XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item38 | 1 | Mtr |
40 | 1.39 | 50 mm2 Single Phase Cable 1.1 KV Grade, XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item39 | 1 | Mtr |
41 | 1.4 | 185 mm2 Single Phase Cable 1.1 KV Grade, XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item40 | 1 | Mtr |
42 | 1.41 | 240 mm2 Single Phase Cable 1.1 KV Grade, XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item41 | 1 | Mtr |
43 | 1.42 | 300 mm2 Single Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item42 | 1 | Mtr |
44 | 1.43 | 400 mm2 Single Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item43 | 1 | Mtr |
45 | 1.44 | 630 mm2 Single Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item44 | 1 | Mtr |
46 | 1.45 | 25 mm2 3.5 Core armoured Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item45 | 1 | Mtr |
47 | 1.46 | 35 mm2 3.5 Core armoured Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item46 | 1 | Mtr |
48 | 1.47 | 50 mm2 3.5 Core armoured Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item47 | 1 | Mtr |
49 | 1.48 | 185 mm2 3.5 Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item48 | 1 | Mtr |
50 | 1.49 | 240 mm2 3.5 Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item49 | 1 | Mtr |
51 | 1.5 | 300 mm2 3.5 Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item50 | 1 | Mtr |
52 | 1.51 | 400 mm2 3.5 Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item51 | 1 | Mtr |
53 | 1.52 | 630 mm2 3.5 Core Cable 1.1 KV Grade,XLPE Insulated Stranded Conductor FRLS type (IS 7098 ammended upto date) Polycab/Havells/Paramount/Gloster | item52 | 1 | Mtr |
54 | 1.53 | Galvanized earthing strips 50mm x3mm. | item53 | 1 | Kg |
55 | 1.54 | Bobin Insulators clamps/cliffs. | item54 | 1 | No |
56 | 1.55 | Back Clamp Collars/Pole Collars G.I. | item55 | 1 | No |
57 | 1.56 | Galvanized ABC Cable Hooks | item56 | 1 | No |
58 | 1.57 | Aluminum paint (Asian/Nerolac/Berger) make. | item57 | 1 | Ltr |
59 | 1.58 | Red oxide paint (Asian/Nerolac/Berger) make. | item58 | 1 | Ltr |
60 | 1.59 | 11 KV Heat Shrinkable Outdoor Cable Termination Kit | item59 | 1 | Set |
61 | 1.6 | 11 KV Heat Shrinkable Outdoor Cable Jointing Kit | item60 | 1 | Set |
62 | 1.61 | 11 Mtr. (IS 2713 540 SP 56)Steel Tubular Poles | item61 | 1 | No |
63 | 1.62 | 9 Mtr. (IS 2713 540 SP 33)Steel Tubular Poles | item62 | 1 | No |
64 | 1.63 | 8 Mtr. (IS 2713 540 SP 15)Steel Tubular Poles | item63 | 1 | No |
65 | 1.64 | 30mm2 ACSR Conductor IS: 398(Part-II) ammended upto date | item64 | 1 | Km |
66 | 1.65 | 50mm2 ACSR Conductor IS: 398(Part-II) ammended upto date | item65 | 1 | Km |
67 | 1.66 | 100mm2 ACSR Conductor IS: 398(Part-II) ammended upto date | item66 | 1 | Km |
68 | 1.67 | 630 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item67 | 1 | No |
69 | 1.68 | 400 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item68 | 1 | No |
70 | 1.69 | 200 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item69 | 1 | No |
71 | 1.7 | 160 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item70 | 1 | Kg |
72 | 1.71 | 100 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item71 | 1 | Kg |
73 | 1.72 | 40 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.\n(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) | item72 | 1 | No |
74 | 1.73 | Rubber gloves Passed as per Standard IS 4770 ammended upto date and working potential of 11 kV | item73 | 1 | Pair |
75 | 1.74 | Rubber shoes sole insulation IS 4770 ammended upto date and working potential of 11 kV | item74 | 1 | Pair |
76 | 1.75 | 20 feet long , 11 kV Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , manufactured from Fibre Reinforced Plastic material , having HV test of 110 kV, push button locking sytem, crocodile grounding clamp , rubber clading to hold, Die cast Alu. Earthing instrument for 30mm diameter (with 4 sq mm copper cable 8 mtrs; top section diameter > 25 mm and bottom section diameter >45 mm) with earthing spike of Standard Make | item75 | 1 | Set |
77 | 1.76 | Battery operated 11-33 kV Voltage Detector (CPRI Tested) complete kit including HV detector probe, 20 feet FRP insulation stick, carrying bag. The detector should have audio as well as visual anunciation, sensing distance of 1 meter for 11kV and 3 meters for 33kV. Bright high intensity Red LED's for visual annunciation even in unfavourable daylight conditions and a buzzer to produce loud beep audible even in noisy backgrounds | item76 | 1 | Kit |
78 | 1.77 | Natural Latex 11kV Rubber Gloves (Type-2 IS 4770; ISI Mark) with test voltage >=17000 V and Working Voltage of 11000 with maximum leakage current at tets voltage of 14mA (rms) [ ISI Mark and IS Conformation on Each glove] | item77 | 1 | Pair |
79 | 1.78 | White Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] | item78 | 1 | No |
80 | 1.79 | Yellow Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] | item79 | 1 | No |
81 | 1.8 | Safety Belt with static and dynamic loading completely as per IS 3521 [ ISI Mark and IS Conformation on Each Belt] | item80 | 1 | No |
82 | 1.81 | UK SIZE 6 and below Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] | item81 | 1 | Pair |
83 | 1.82 | UK SIZE 7 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] | item82 | 1 | Pair |
84 | 1.83 | UK SIZE 8 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] | item83 | 1 | Pair |
85 | 1.84 | UK SIZE 9 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] | item84 | 1 | Pair |
86 | 1.85 | UK SIZE 10 and above Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] | item85 | 1 | Pair |
87 | 1.86 | 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(adjustib and 1-Piece Measuring Tape) BOSCH/DEWALT/TAPARIA | item86 | 1 | No |
88 | 1.87 | Clamp Meter, Conforms to IEC 61010, CAT II 600V safety rated, 600A AC current measurement, AC/DC voltage, resistance, continuity & data hold function, 2 years manufacturer warranty [FLUKE/DIGI SENSE/ MOTWANE/EXTECH] | item87 | 1 | No |
89 | 1.88 | 18 feet Fiber Link Rod | item88 | 1 | No |
90 | 1.89 | 18 feet Bamboo Link Rod | item89 | 1 | No |
91 | 1.9 | Wooden Ladder A Class Budloo [Finished Length of 17' (3" by 1.5") ; Finished Step (2" by 1.5 ") ; Bottom Width 18"; Step to step distance 13"] alongwith MS Straps on both side of each step | item90 | 1 | No |
92 | 1.91 | 16 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type (IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent | item91 | 1 | Mtr |
93 | 1.92 | 25 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type (IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent | item92 | 1 | Mtr |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail