| Name of Work: CONSTRUCTION OF DRUG WARE HOUSE AT MOHAMDABAD DISTT. FARRUKHABAD. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earth work in excavation in trenches for foundations pipes cable etc in ordinary soil (Loam clay or sand ) including lift upto 1.5m lead upto 50m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i/c (up to 1.50 m) | 1640 | CUM | |
| 2 | 2 | Earth work in excavation in trenches for foundations pipes cable etc in ordinary soil (Loam clay or sand ) including lift upto 1.5m lead upto 50m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i/c (1.50-3.00 m) | 170.7 | CUM | |
| 3 | 3 | Earth work in excavation in trenches for foundations pipes cable etc in ordinary soil (Loam clay or sand ) including lift upto 1.5m lead upto 50m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i/c (3.00-4.50 m) | 99.2 | CUM | |
| 4 | 4 | Filling BY CARTED earth in trenches, plinth, sides of foundation etc. inlayers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering including lead upto 50m & lift upto 1.50m. | 1240 | CUM | |
| 5 | 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distsnce of 50m out side the periphery of area cleared. under floor Local sand. | 255 | CUM | |
| 6 | 6 | Providing and laying Cement concrete 1:4:8 (1cement : 4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. | 331.914 | CUM | |
| 7 | 7 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor or Chlordane will be used.The rate of application of chemical emulsion shall be as follows:- (1) Treatment for masonary & foundation @ 5 litres per sqm (2) Back fill in immediate contact with foundation @ 7.5 litres per sqm (3) Treatment of top surface of plinth filling @ 5 liters per sqm (4) Treatment of soil along external parameter of building @ 7.50 litres per sqm. (5) Treatment of soil under apron along external perimeter @ 5 litres per sqm. | 1745.5 | SQM | |
| 8 | 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All works upto plinth level | 610.2 | CUM | |
| 9 | 9 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level | 741 | CUM | |
| 10 | 10 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors,roofs,landing,beams and balconies (Plan area to be measured). | 5332 | SQM | |
| 11 | 11 | Add for using extra cement in the items of design mix over and above the specified cement content therein. | 950.64 | QTL | |
| 12 | 12 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).\nNote:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. | 337 | CUM | |
| 13 | 13 | Class-150 brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour tools and plants etc, required for proper completion of the work. | 52.8 | CUM | |
| 14 | 14 | Class-150 brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour tools and plants etc, required for proper completion of the work. | 350 | CUM | |
| 15 | 15 | Class-150 brick work in 1:6 cement and coarse sand mortar in super structure including supply of all materials, labour tools and plants etc, required for proper completion of the work | 353.25 | CUM | |
| 16 | 16 | Class-150 brick work in Half brick masonry in super structure above plinth level including necessary cutting and moulding of brick work as required with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure with Cement mortar 1:4 (1 cement :4 coarse sand) | 200 | CUM | |
| 17 | 17 | Providing and laying damp-proof course 25 mm thick with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size). | 39.6 | SQM | |
| 18 | 18 | Mild steel or iron in plain work such as reinforced concrete wrought to required shape as necessary including supply of all steel and wastage and over lapping and hooks | 2744.02 | QTL | |
| 19 | 19 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. | 14 | NOS | |
| 20 | 20 | Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. | 9 | NOS | |
| 21 | 21 | Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. | 112 | NOS | |
| 22 | 22 | Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. | 194 | NOS | |
| 23 | 23 | Indian sal wood wrought framed and fixed including simple mouldings straight work as in chaukhats including supply of all material and labour for proper completion of work. | 0.98 | CUM | |
| 24 | 24 | Supplying and fixing of flush doors commercial quality conforming to is 2202 Part I(1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fittings with necessary screws complete including ISI marked Stainless Steel butt hinges with necessary screws (35 mm thick) | 44.95 | SQM | |
| 25 | 25 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). | 44.95 | SQM | |
| 26 | 26 | P/F steel / wooden chaukhats in position including supply of material labour T&P etc. required for proper completion of work. | 152.21 | SQM. | |
| 27 | 27 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:2nd class teak wood 50x12mm | 107.1 | RM | |
| 28 | 28 | M.S. or iron works of small sizes and sections such as holding down bolts, hold fast, tie rods gradings etc. wrought to required form including supply to steel bolt, nuts wastage etc and their fixing required for proper completion of the work. | 192.14 | KG | |
| 29 | 29 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | 18 | NOS | |
| 30 | 30 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | 18 | NOS | |
| 31 | 31 | M.S. or iron work in angle iron door and window frame including cutting welding and wastage including supply of all material, labour T&P etc required for proper completion of work | 23.4 | KG | |
| 32 | 32 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window single panel with S.S. friction hinges (300x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension.(Area of window upto 0.75 sqm.) | 30 | SQM | |
| 33 | 33 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (300x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). | 4.5 | SQM | |
| 34 | 34 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (350x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). | 63.36 | SQM | |
| 35 | 35 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.300 x 19 x 1.9 mm | 66 | NOS | |
| 36 | 36 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. | 150 | NOS | |
| 37 | 37 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per Requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). | 579.65 | KG | |
| 38 | 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness | 105.39 | SQM | |
| 39 | 39 | Providing and fixing fly proof wire gauge, to windows and clerestory windows & doors with M.S. flat 16x3 mm nd nuts and bolts complete. stainless steel (grade 304) wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. | 98 | SQM | |
| 40 | 40 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ Masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions,to seal the gap between the building structure and all its interfaces with curtain glazing to make it Watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making Necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a | 42.88 | SQM | |
| 41 | 41 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, Comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No. 25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | 43 | SQM | |
| 42 | 42 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame. | 30 | RMT | |
| 43 | 43 | Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. | 9.5 | SQM | |
| 44 | 44 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3.15 mm thick M.S. gusset plates at the junctions and corners, all necessary fittings lock rail of 15\" length of oxidised iron and, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces | 2.1 | SQM | |
| 45 | 45 | M.S or iron work of small sizes and section as holding down bolts, hold fast, tieds grading etc. wrought to required fram including supply to steel bolt, nuts wastage etc. and their fixing required for proper completion of the work M.S Grill & Railling | 577 | KG | |
| 46 | 46 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | 1325 | KG | |
| 47 | 47 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm (3/4\"x3/8x1½\") and braced with flat iron diagonals 20x5 mm (3/4\"x3/16\")size, with top and bottom rail of T-iron dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. | 7.2 | SQM | |
| 48 | 48 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3\"x1/8 gauge) cold rolled M.S. lath inter locked through out their entire length and joined together at the end by and locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top covers and spring. | 63.75 | SQM | |
| 49 | 49 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3\"x1/8 gauge) cold rolled M.S. lath inter locked through out their entire length and joined together at the end by and locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete Providing and fixing 27 cm long wire spring grade II for rolling shutter | 14 | NOS | |
| 50 | 50 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3\"x1/8 gauge) cold rolled M.S. lath inter locked through out their entire length and joined together at the end by and locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete Providing and fixing top cover for rolling shutters | 25 | RMT | |
| 51 | 51 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3\"x1/8 gauge) cold rolled M.S. lath inter locked through out their entire length and joined together at the end by and locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete Providing and fixing ball bearing for rolling shutters | 14 | NOS | |
| 52 | 52 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3\"x1/8 gauge) cold rolled M.S. lath inter locked through out their entire length and joined together at the end by and locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete Extra for providing mechanical device, chain and crank operation for rolling shutters. Shutter above11.2Sq.M.(120sft) but upto16.8Sq.M. (180 sft) area. | 63.75 | SQM | |
| 53 | 53 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. | 12 | NOS | |
| 54 | 54 | Providing and laying integral cement based treatment (Brick Coba) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by engineer in charge and and consisting of : (i) 1st layer of 22 mm to 25mm thick base of cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound conforming to IS:2644 in the recommended proportion over the levelling course. joints sealed and grounted with cement slurry mixed with waterproofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportions . iii finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @8cudm/sqm thoroughly embeded in the 2nd layer | 1864.4 | SQM | |
| 55 | 55 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in\nACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm | 62.37 | SQM | |
| 56 | 56 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in\nACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage For horizontal surface one coat @1.10 kg per sqm. | 33.2 | SQM | |
| 57 | 57 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 186 | SQM | |
| 58 | 58 | 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering including arises, interior rounded angles chamfers and of rounded angles not exceeding 80 mm in girth and finished even and smooth. 1:6 cement and coarse sand | 3147.52 | sqm | |
| 59 | 59 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering including arises, interior rounded angles chamfers and of rounded angles not exceeding 80 mm in girth and finished even and smooth. 1:6 cement and coarse sand | 2773.96 | SQM | |
| 60 | 60 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering including arises, interior rounded angles chamfers and of rounded angles not exceeding 80 mm in girth and finished even and smooth. 1:4 (1 cement: 4 coarse sand) In Plinth | 203.41 | SQM | |
| 61 | 61 | 12 mm thick plastering on ceilings and soffits of stair upto floor two level instead of plastering in walls. 1 cement : 3 coarse sand | 3064.34 | SQM | |
| 62 | 62 | 12 mm 1:4 (1 cement: 4 coarse sand) cement plaster in single coat of rough side of single or half brick wall for interior plastering upto floor two level including arises internal rounded angles chamfers, and of rounded angles not exceeding 80 mm. in girth and finished even and smooth. | 415.422 | SQM | |
| 63 | 63 | Making Groove plastered surface or moulding to R.C.C. projections. | 3005.04 | RMT | |
| 64 | 64 | Making drip course in plastered surface or moulding to R.C.C. projections. | 129.2 | RMT | |
| 65 | 65 | R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in Foundation & raft, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item. | 28.3 | CUM | |
| 66 | 66 | R.C.C. work with cement approved coarse sand and 2cm Gauge approved stone ballast in the proportion of 1:1.5:3 , excluding its fixing and binding wire and including necessary centering and shuttering etc and also including S/o all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. But in plinth beams in 1:1.5:3 i.e. having spans upto 6 metres. & Lintel of door, window, ventilators, sunshade etc. | 20.3 | CUM | |
| 67 | 67 | R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in Columns, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item. | 23 | CUM | |
| 68 | 68 | R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in Slab, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item. | 38.49 | CUM | |
| 69 | 69 | Providing and laying of 8 to 10 mm thick ivory or light shade vitrified tiles of specified size in flooring or skirting laid with 1:3 cement mortar (1 cement:3coarse) finishing with cement slury & with pigment grouting & piloshing complete i/e supply of all material, labour T&P required for proper completion of work Vitrified Tile Matt/ Antiskid finish of size 300 x 300 mm & in flooring 600X600 mm. | 184.68 | SQM | |
| 70 | 70 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete | 285 | SQM | |
| 71 | 71 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. | 70 | SQM | |
| 72 | 72 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.20 mm thick | 4.88 | SQM | |
| 73 | 73 | Granite stone slab 18 mm thick mirror polished quarter rounded with anti skid lines in treads of stair case full length flooring over 20 mm (average) thick base laid over and jointed with cement slurry mixed with pigment to match the shade of including rubbing and polishing complet with base of cement mortar 1:4 (1cement : 4 coarse sand ) etc. complete. | 422.44 | SQM | |
| 74 | 74 | 62 mm thick Ironite cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement iron chips mix : 2 graded stone aggregate, 6mm nominal size) by volume, iron chips mixed @ 4 kg per 1 sqm of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. | 1562 | SQM | |
| 75 | 75 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. | 7.2 | SQM | |
| 76 | 76 | Providing and fixing glass strips of 5.5mm thick in joints of floors and skirtings at the time of laying floors flush with floor lavel including all materials labour tools and plants etc. complete of 3.7cm (1½\") depth | 404 | RMT | |
| 77 | 77 | Distempering with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N Shalimar, Asian Paints after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth including cost of all material. | 6005 | SQM | |
| 78 | 78 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) | 2574.69 | SQM | |
| 79 | 79 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 8604.86 | SQM | |
| 80 | 80 | Painting two coats over priming coat on steel & other metal surface upto 10 cm width or grith or small articles not exceeding 0.10 sqmt. In areas with superior synthetic enamel such as Luxol 3Hi gloss aqcolite superlac. Dulux specified finishing and wooden work | 288.6 | SQM | |
| 81 | 81 | Providing /laying of light cinder fillingbrick ballast under floor of toilet /sunken roofs | 3.14 | CUM | |
| 82 | 82 | Cement Concreate flooring 1:2:4 (1 Cement: 2 C.sand: 4 Stone aggreagates of Sizes 20mm nominal Size laid in one layer finished with floating cost of neat cement (40mm thick floor) as desired by E/I/ | 161.6 | SQM | |
| 83 | 83 | Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 150 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) | 180 | RMT | |
| 84 | 84 | Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. | 70 | SQM | |
| 85 | 85 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. | 238 | SQM | |
| 86 | 86 | 25 mm cement concrete flooring (1 cement :2 coarse sand:4 stone aggregates of sizes 12.5 mm and below ) by laying over base concrete finished with floating coat of neat cement | 27 | SQM | |
| 87 | 87 | Wiring point for light with 1.5 sq.mm FRLSH P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash | 371 | Nos | |
| 88 | 88 | Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash | 30 | Each | |
| 89 | 89 | Wiring point for fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash | 141 | Each | |
| 90 | 90 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & socket etc, complete in all respect including matching colour wash. | 98 | Each | |
| 91 | 91 | Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage PVC conduit partly laid in slab alongwith reinforcemet before concreting and partly concealed in wall one no 14 SWG copper earth continuity wire etc, complete in all respects including matchning colour wash. | 666 | Rmt | |
| 92 | 92 | Supply and wiring of submiain with two number 4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SWG copper earth continuity wiere including matching colour wash etc. complete in all respect. | 448 | Metre | |
| 93 | 93 | Supply and wiring of submiain with 4 number 10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 10 SWG copper earth continuity wiere including matching colour wash etc. complete in all respect. | 301 | Metre | |
| 94 | 94 | Supply and fixing and concealing of 20mm dia. 16 SWG (1.5 mm) thick PVC conduit pipe in the wall including cutting of brick work, laying of conduit and fixing it with M.S. hooks and then plastering with cement, sand mortar finished to the level, with matching colour wash including cost of proper threading of the conduit & providing necessary socket, bends and chuck nuts and as directed by the Engineer in charge with the supply of all material labour and T&P required for proper completion of work. | 850 | Metre | |
| 95 | 95 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. | 140 | Each | |
| 96 | 96 | Erection and testing exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc. complete in all respects. | 15 | Each | |
| 97 | 97 | Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. | 140 | Each | |
| 98 | 98 | Supply fixing of electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. | 140 | Each | |
| 99 | 99 | Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system BEE 5 star rated-1200 mm sweep | 140 | Each | |
| 100 | 100 | Supply & fixing of recess mounting round 16 to 18 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) | 537 | Each | |
| 101 | 101 | Supply & fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA) | 10 | Each | |
| 102 | 102 | Supply & fixing of LED Square Light with batten suitable for up to 2 x 36 watt LED tube light complete including tube etc on surface complete in all respects | 155 | Each | |
| 103 | 103 | S/F of single Wall light with wall bracket on matching M.D.F.E.G..board base or wall etc. complete in all respects. | 37 | Each | |
| 104 | 104 | Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.4 Way TPN | 2 | Each | |
| 105 | 105 | Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.6 Way TPN | 4 | Each | |
| 106 | 106 | Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.8 Way TPN | 2 | Each | |
| 107 | 107 | Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.12 Way TPN | 2 | Each | |
| 108 | 108 | Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. | 125 | Each | |
| 109 | 109 | Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp. 4 Pole MCB | 26 | Each | |
| 110 | 110 | Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. 4 Pole MCB | 14 | Each | |
| 111 | 111 | Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 100 Amp. 4 Pole MCB | 24 | Each | |
| 112 | 112 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. | 8 | Each | |
| 113 | 113 | Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. | 27 | Each | |
| 114 | 114 | Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. | 9 | Each | |
| 115 | 115 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. | 7 | Nos. | |
| 116 | 116 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. | 75 | Metre | |
| 117 | 117 | Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. | 323 | Metre | |
| 118 | 118 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.95 sqmm 3.5 core | 201 | Rmt. | |
| 119 | 119 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 25 sqmm 4 core | 201 | Rmt. | |
| 120 | 120 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.16 sqmm 4 core | 65 | Rmt. | |
| 121 | 121 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.10 sqmm 4 core | 85 | Rmt. | |
| 122 | 122 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.10 sqmm 2 core | 279 | Rmt. | |
| 123 | 123 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 6 sqmm 2 core | 178 | Rmt. | |
| 124 | 124 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 95 sqmm 3.5 core | 4 | Each | |
| 125 | 125 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 25 sqmm 4 core | 4 | Each | |
| 126 | 126 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 16 sqmm 4 core | 4 | Each | |
| 127 | 127 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 10 sqmm 4 core | 4 | Each | |
| 128 | 128 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 10 sqmm 2 core | 15 | Rmt. | |
| 129 | 129 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 6 sqmm 2 core | 7 | Rmt. | |
| 130 | 130 | Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 95 Sq.mm | 10 | Each | |
| 131 | 131 | Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 25 Sq.mm | 12 | Each | |
| 132 | 132 | Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 16 Sq.mm | 12 | Each | |
| 133 | 133 | Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 10 Sq.mm | 58 | Each | |
| 134 | 134 | Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 6 Sq.mm | 22 | Each | |
| 135 | 135 | S & F of surface/flush mounting 4 ways V TPN distribution board with additional door cithout MCB complete in all respect, as directed at site by Engineer in charge. | 3 | Each | |
| 136 | 136 | S & F of 63 Amp TP MCB (10KA) C Curve. | 3 | Each | |
| 137 | 137 | S & F of 40 Amp TP MCB (10KA) C Curve. | 7 | Each | |
| 138 | 138 | MAIN L.T. PANEL Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel Incoming :One (1) No 315 Amp. 4P MCCB of 35 KA Breaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-315A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No. 400 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.160Amps FP MCCB of 25 KA (Ics=Icu) Breaking Capacity-2 Nos.100Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity-2 Nos.63Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity-2 Nos.40Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity-5 Nos.40Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity- 2No. Spare 63Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 2No. Spare | 1 | Set | |
| 139 | 139 | Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.6 sqmm 2 core | 175 | M | |
| 140 | 140 | Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 2 core | 125 | M | |
| 141 | 141 | Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 sqmm 2 core | 115 | M | |
| 142 | 142 | Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm 4 core | 115 | M | |
| 143 | 143 | Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 sqmm 3 -1/2 core | 75 | M | |
| 144 | 144 | VIDEO SURVEILLANCE SYSTEM (CCTV)\n'Supply, Installation and Testing of Video Surveillance Camera and all required accessories as 'per below and detail tender specifications. 'Outdoor, IP, PTZ camera\n'Focal Length: 4 mm 84 mm 'Optical Zoom: 26X or better 'Resolution: 1920 x 1080 'Illumination: 1 Lux (Colour)\n'IR Cut filter: Yes with IR distance 100m 'Onvif S profile: Yes\n'Auto Iris: Yes (PIris)\n'Frame Rate: 25 fps (1080p) and 50 fps (720p) 'Interface: RJ45 (network) Honexwell/HDZ302LIK or equivelant make. | 2 | each | |
| 145 | 145 | Outdoor, IP67, Bullet Camera 'Focal Length: 3 mm 10 mm\n'Verx Focal: Yes 'Resolution: 1920 x 1080\n'Illumination: 0.5 Lux (Colour)\n'IR Cut filter: Yes with IR distance 30m 'Onvif S profile: Yes\n'Auto Iris: Yes (PIris) 'Frame Rate: 25 fps (1080p) 'Interface: RJ45 (network) 'POE enabled\nHoneywell/HICC2600TVI or equivelant make. | 12 | each | |
| 146 | 146 | Indoor, IP, Dome Camera, Recessed/Surface/Pendent/Wall mounted 'Focal Length: 3 mm 9 mm\n'Verx Focal: Yes 'Resolution: 1920 x 1080\n'Angle of Vision 360 Degree with Fish Exe lens 'Illumination: 0.5 Lux (Colour)\n'IR Cut filter: Yes with IR distance 15m 'Onvif S profile: Yes\n'Auto Iris: Yes (PIris) 'Frame Rate: 25 fps (1080p) 'Interface: RJ45 (network) 'POE enabled\nHoneywell/HIDC2600TVI or equivalent make. | 46 | each | |
| 147 | 147 | Supply Installation testing of RJ45 Jacks (Outdoor Type) for Data/Voice outlet with 'Modular/Surface Metallic box for \nCamera/Security system Connectivity, TYCO/13755055x or equivalent make. | 2 | each | |
| 148 | 148 | Supply, installation, testing and commissioning of IP digital video management software complete with compatible server grade PC for the software, complete with licenses equal to the number of cameras ( Not less than 64 Cameras ), client licenses, and all other licenses required to integrate kexboards with PTZ controllers, monitors, etc. The set shall come with RAID backup device sufficient to store all cameras at 3 MP resolution for minimum 30 Daxs Backups & Should be enable client to monitor & Control completelx from remote location.\n'Processor: Intel Xeon Dual Processor 3.4 GHz, 800FSB, 6 MB Cache or better 'Motherboard: Latest Intel Original Mother Board\n'RAM: 8 GB\n'Video Card: In built for 2 nos 4Kmonitors 'Monitors: (2) 27\" LED Monitor\n'Operating System: MS Windows or equivalent make. | 1 | each | |
| 149 | 149 | Supply and Installation of 42\" Colour LED Full HD Flat Screen Monitor | 2 | each | |
| 150 | 150 | TIME ATTENDANCE AND ACCESS CONTROL SYSTEM\n'Supply, Installation and testing of All in one Biometric (finger Print) Reader, and Proximity\n'Card reader (13.56 MHz), 1500 Users capacity, 50000 or more transaction storage, Ethernet 'connectivity. Honeywell/HONFIN4000HID10K or equivalent make. | 3 | each | |
| 151 | 151 | Supply, Installation and testing of time attendance software (PC based) Honeywell/Eon\nTime or equivalent make. | 1 | each | |
| 152 | 152 | Supply, Installation and testing of Access Control sxstem software (PC based) Honeywell/WPS4 or equivalent make. | 1 | each | |
| 153 | 153 | Supply Smart Cards (13.56Hz) for Access control and Time attendance sxstem Honeywell/PX4H or equivalent make. | 150 | each | |
| 154 | 154 | 2Reader/Door Controller, Ethernet or Rs485 interface. Inbuilt Battery backup, Minimum 4 'Input/Output contacts/relay per reader. 32 bit processor, 10,000 card holders, 1,00,000 'transaction Logs with Enclosure & Power Supply\nHoneywell/PRO3000 or equivalent make. | 3 | each | |
| 155 | 155 | Surface laying of 8 core 0.75sq. mm ATC PVC insulated & sheathed, twisted pair, Al Mxlar 'shielded and overall FRLS \nPVC sheathed cable in 25 mm PVC medium duty ISI Marked 'Conduit (rates of conduit is exclusive) | 100 | each | |
| 156 | 156 | Supply, Installation, Testing and Commissioning of Electro Magnetic Lock (600 Lbs) with 'magnetic contact Single \nLeaf and power Supply, Algatec/UL275LSL or equivelant make. | 3 | each | |
| 157 | 157 | INTELLIGENT PARKING MANAGEMENT CUM BOOM BARRIER\n'Supply, Installation, Testing and Commissioning of Boom barrier 620 Rapid up to 3 MTR length , pair of photo cell , and push button and accessories.\nFACC/620SR or equivalent make. | 2 | each | |
| 158 | 158 | Supply, Installation, Testing and Commissioning of 2 core 1.5 flexible FRLS Armoured cable. | 2100 | each | |
| 159 | 159 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75 mm) | 11 | Each | |
| 160 | 160 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket outlet | 11 | Each | |
| 161 | 161 | Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.2 Pair | 402 | Metre | |
| 162 | 162 | S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same | 3 | Each | |
| 163 | 163 | Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cutting and making good the walls & floors as per requirement.150mm | 32 | Metre | |
| 164 | 164 | Water Cooler with RO\nSITC of water cooler with RO having storage capacity 80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the water should drop bx 150 C within a hour, The water cooler should be comprising of hermeticallx sealed compressor, fan motor, condensing unit, water tank surrounded bx evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The bodx of water cooler will be made from Stainless Steel. with all accesories | 2 | Each | |
| 165 | 165 | FIRE PUMPS - ELECTRICAL Supply, installation, testing and commissioning of horizontal single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.\nCost Should be Inclusive the Pressure Switch,Required Control Panel,Cables of Suitables size,Earthing & Its Accessories etc. or other electrical item as Required.Capacity 450 LPM at 3.5 Kg/cm2 (Terrace Pump). | 1 | Set | |
| 166 | 166 | Fire Hose Cabinet Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). | 2 | Each | |
| 167 | 167 | 63mm dia single outlet Pressure type GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make. | 2 | Each | |
| 168 | 168 | First aid hose reel with 25 mm dia, 36 m long rubber hose, ball valve, piping and GM nozzle | 2 | Each | |
| 169 | 169 | 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long | 4 | Each | |
| 170 | 170 | Standard short size GM branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved. | 2 | Each | |
| 171 | 171 | Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mounted box of M.S. construction with glass door to house the above mentioned components. | 1 | Set | |
| 172 | 172 | Constructing masonary chamber 90 x 90 x100 cm. inside with 150 class designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine sand) for sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete | 17 | Each | |
| 173 | 173 | Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately) 50 mm dia. | 1 | Each | |
| 174 | 174 | Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately) 100 mm dia.pipe | 1 | Each | |
| 175 | 175 | Class II Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 100 mm dia. | 1 | Each | |
| 176 | 176 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.100 mm dia | 1 | Each | |
| 177 | 177 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 100 mm dia | 2 | Each | |
| 178 | 178 | Providing and fixing in position the industrial type Pressure Gauges with gun metal / brass valves complete as required | 2 | Each | |
| 179 | 179 | Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipe . (Specification for Underground Fire Hydrant Make: Jindal Hissar/ Surya/ Tata/ SAIL. (Under ground) 100 nominal bore (class C) | 75 | M | |
| 180 | 180 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe.100 mm nominal bore (class C) | 32 | Rm | |
| 181 | 181 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 80 mm nominal bore (class C) | 16 | Rm | |
| 182 | 182 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 65 mm nominal bore (class C) | 15 | Rm | |
| 183 | 183 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. (Above Ground) Threaded joint upto 50mm diameter pipe.Welded joint above 50mm diameter pipe. 25 mm nominal bore (class C) | 9 | Rm | |
| 184 | 184 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 4.5 kg | 20 | Nos. | |
| 185 | 185 | Providing and fixing Dry Chemical Powder type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 5 Kg. | 20 | Nos. | |
| 186 | 186 | Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required. \n | 25 | Rm | |
| 187 | 187 | Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. \n | 25 | Rm | |
| 188 | 188 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required. \n | 18 | Rm | |
| 189 | 189 | Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness | 22 | Rm | |
| 190 | 190 | Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness | 22 | Rm | |
| 191 | 191 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required. | 25 | Rm | |
| 192 | 192 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required. \n 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam) | 25 | Rm | |
| 193 | 193 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge Using rough Kota stone | 4.6 | Sqm | |
| 194 | 194 | Supplying and fixing C.I. cover without frame for manholes 455x610 mm rectangular C.I. cover (light duty) the weight\nof the cover to be not less than 23 kg | 18 | Nos. | |
| 195 | 195 | Supply,Installation,Testing & Commissioning of Microprocessor based 2 Loops analogue addressable type fire alarm control panel with 640 character LCD display, QWERTY keypad for programming having capacity to integrate 159detector &159 modules.ThePanel shall have BACKNETCARD | 1 | Nos. | |
| 196 | 196 | Supply, Installation, Testing And Commissioning of UL Listed Analog addressable Self Acclimatising Multi Sensor smoke detector with\nmounting based LED, Address Switch from 01159, to programme the detectors, complete as per all requirements of technical\nspecifications & contracts works. | 135 | Nos. | |
| 197 | 197 | Supply, Installation, Testing And Commissioning of UL Listed, Fixed temperature cum rate of rate of rise heat detector as per all\nrequirements of technical specifications & contracts works.\n | 2 | Nos. | |
| 198 | 198 | Supply, Installation, Testing And Commissioning of Response Indicator to show the status of above false ceiling detector | 12 | Nos. | |
| 199 | 199 | Supply, Installation, Testing And Commissioning of UL listed, Flush or surface mounted Manual Call Point in manufacturers prescribed\nmatching red enamel outlet box complete with key operated testreset lock. The word FIRE shall appear in front of station as per all\nrequirements of technical specifications & contracts works. | 2 | Nos. | |
| 200 | 200 | Supply, Installation, Testing And Commissioning of Ul Listed Surface mounted addressable type fully solid state circuitory dual tone Electronic speaker cum hooters with strobe lights of 110 Cd intensity including Addressable Control/Relay module as per all requirements of technical specifications & contracts works. | 2 | Nos. | |
| 201 | 201 | Supply, Installation, Testing and Comissioning of Isolator Module for fault isolator. | 3 | Nos. | |
| 202 | 202 | Supply, Installation, Testing and Comissioning of 2 Core X 1.5 Sq.mm FRLS twisted pair shielded, PVC insulated armoured copper conductor\ncable. | 1400 | RM | |
| 203 | 203 | Supply, Installation, Testing and Comissioning of 4 Core X 1.5 Sq.mm FRLS twisted pair shielded, PVC insulated armoured copper conducto\ncable. | 45 | RM | |
| 204 | 204 | Supply, Installation, Testing and Commissioning of 8 zone IP based, digital Voice Alarm controller expandable upto 128 zones. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring , log recording, volume control and amplifier switchover. The Voice alarm controller should also have the following functions :\n . 255 Priorities \n . Time schedule broadcasts \n . Its own PTT microphone\n . Capable of amplifier redundancy \n . 8 trigger inputs/outputs\n | 1 | Nos. | |
| 205 | 205 | Supply, Installation, Testing and Commissioining of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions:\n Builtin monitoring loudspeaker Detachable gooseneck microphone\n LCD touchscreen display\n Audio input | 1 | Nos. | |
| 206 | 206 | Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz20KHz\nwith a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W | 37 | Nos. | |
| 207 | 207 | Supply, Installation, Testing and Commissioning of 10W Ceiling Speaker with max SPL1M/1W 92dB . Frequency response of 150 Hz17 kHz\nwith a dispersion angle of 170 deg. The speaker should have tappings at 10W/5W/2.5W | 20 | Nos. | |
| 208 | 208 | Supply, Installation, Testing and Commissioning of 480W Power Amplifier | 2 | Nos. | |
| 209 | 209 | Supply, Installation, Testing and Commissioning of Music Source – CD / DVD / FM Player | 1 | Nos. | |
| 210 | 210 | Supply, Installation, Testing and Commissioning of Speaker cables – 2C X 1.5 Sq.mm Armoured cable with required accessories | 1245 | Meter | |
| 211 | 211 | Supply, Installation, Testing and Commissioning of Rack for mounting the equipements | 1 | Nos. | |
| 212 | 212 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 99 | KG | |
| 213 | 213 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes | 4.95 | SQM | |
| 214 | 214 | French spirit polishing : Two or more coats on new works including a coat of wood filler | 1.9 | SQM. | |
| 215 | 215 | Making expansion joint (vertical) by providing & filling 12 mm thick bitumin bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound & then covering by 200 mm Aluminium fluted strips 3.15mm thick for proper completion of the work. | 15.75 | RMT | |
| 216 | 216 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | 2391.2 | SQM | |
| 217 | 217 | Granular Sub-Base with Close Graded Material (Table: 400-1): Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. For Grading-I Material (By Mix in Place Method). | 359 | CUM | |
| 218 | 218 | Providing and fixing in position pre-moulded joint filler in expansion joints. | 12830.4 | RM | |
| 219 | 219 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. | 12830.4 | RM | |
| 220 | 220 | Providing and laying Non pressure NP 3 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes | 84 | RM | |
| 221 | 221 | Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design. | 180 | RM | |
| 222 | 222 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 50mm nominal bore.Supplying and fixing of specials for pressure pipe. | 105 | Rm. | |
| 223 | 223 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.50mm nominal bore. | 1 | Nos. | |
| 224 | 224 | Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design \n | 1 | Each | |
| 225 | 225 | Constructing brick masonry chamber 600 x 600 x 900 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design | 8 | Each | |
| 226 | 226 | Providing and admixing water proofing compound (impermo or equivalent) @ 1 kg per 50 kg of cement in all RCC elements of water retaining structures (including RCC elements of staging foundation) required quantities as per the approved structural drawings.Reinfocement with TMT steel bars for RCC work including straightning, cutting, bending, placing in position and binding all complete.Centering & shuttering including strutting, propping etc and removal of form for all types/ categories/ classes of RCC and PCC upto all leads and lifts Providing embedding and fixing in position Aluminium sheet 200 mm wide and 1.90 mm thick at the horizontal joints between two successive lifts of walls of tanks as well as between uppermost lifts of walls and beam/slab of roof dome in required lengths, out of which 100 mm width shall be embedded in the lower layer of RCC and remaining 100 mm width in the successive layer of RCC Brick work with FPS bricks of class designation 75 in cement mortar 1:6 (1cement : 6 coarse sand) in retaining, to wall for CC pavement.Cement concrete flooring 50mm thick with 20mm nominal size stone aggregate in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with floating coat of neat cement including cement slurry on the treades and landing of the staircase, on the steps from the finished ground level to the plinth, on terrace balcony and on top external surface (terrace of tank roof)18 mm thick cement plaster in skirting and risers of steps with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a neat of floating cement.Soil testing & verification of SBC of soil (Refer particular specifications also) Structural design & drawing including necessary submission of design/details, approval etc. all complete (Refer particular specifications also) Testing of tank (Refer particular specifications also) including making all necessary arrangements for filling of tank etc. all complete. Disinfection and commissioning of tank Underground Tank 100 KL (50KL for Fire + 50 KL for Drinking Water ). | 100000 | Liter | |
| 227 | 227 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered & Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered | 100 | sqm | |
| 228 | 228 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20mm square bar | 158 | Nos. | |
| 229 | 229 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter | 36 | No. | |
| 230 | 230 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. | 450 | M | |
| 231 | 231 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia | 450 | M | |
| 232 | 232 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 444.08 | cum | |
| 233 | 233 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. | 9 | Cum | |
| 234 | 234 | Transportation Charges of drilling equipment including assembly and other material as required. | 1 | Each | |
| 235 | 235 | Drilling of 675 mm. dia by rotary machine | 80 | Meter | |
| 236 | 236 | Supply & laying of 350 mm. dia housing pipe (8 mm. thick) | 30 | Meter | |
| 237 | 237 | Supply & laying of 200 mm. dia blind pipe (8 mm. thick) | 25 | Meter | |
| 238 | 238 | Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) | 25 | Meter | |
| 239 | 239 | Supply & fixing of 350 mm. dia Socket | 6 | Each | |
| 240 | 240 | Supply & fixing of 200 mm. dia Socket | 8 | Each | |
| 241 | 241 | Supply & fixing of 200 mm. dia Bail plug | 1 | Each | |
| 242 | 242 | Supply & fixing of 350 mm. dia well cap | 1 | Each | |
| 243 | 243 | Supply & fixing of 350x200 mm. dia reducer. | 1 | Each | |
| 244 | 244 | Supply & fixing of 350 mm. dia housing clamp | 1 | Each | |
| 245 | 245 | Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. | 25 | Cum. | |
| 246 | 246 | Development by air compressor including Transportation. | 30 | Hours | |
| 247 | 247 | Development by O.P. Unit including Transportation. | 40 | Hours | |
| 248 | 248 | Supply of 7.5 HP KSB make submersible pump set model BPD 302/4+UAMI 150/6/22-203 (S/D) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition 7.5 HP 6 stage pipe.A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm.B - Total Head of pump set 45 m. | 2 | Each | |
| 249 | 249 | Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. | 60 | Meter | |
| 250 | 250 | Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. | 1 | Each | |
| 251 | 251 | Supply of 80mm dia M.S. column pipe of class 'C' both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. | 60 | Meter | |
| 252 | 252 | Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. | 2 | Each | |
| 253 | 253 | Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. | 1 | Each | |
| 254 | 254 | Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. | 2 | Each | |
| 255 | 255 | Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. | 1 | Each | |
| 256 | 256 | Supply of 80mm dia C.I. tee heavy quality i/c cost of material. | 1 | Each | |
| 257 | 257 | Supply of Guru/Fibing or equivalent make pressure gauge. | 1 | Each | |
| 258 | 258 | Erection & commissioning of pumping plants complete along with electric wiring. | 1 | Each | |
| 259 | 259 | Supply of steel wire rope of 1/2\" size | 60 | Meter | |
| 260 | 260 | Proving and Fixing of Exhaust Fan (450mm Size) of Havells/Crompton Greeves/Bajaj Make Complete as required for proper completion of the work. | 16 | Each | |
| 261 | 261 | Proving and Fixing of 600mm wall mounted air circulator of Havells/Crompton Greeves/Bajaj Make Complete as required for proper completion of the work. | 16 | Meter | |
| 262 | 262 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests | 1 | each | |
| 263 | 263 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid | 6 | each | |
| 264 | 264 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | 6 | each | |
| 265 | 265 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia | 6 | each | |
| 266 | 266 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia | 4 | each | |
| 267 | 267 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | 5 | each | |
| 268 | 268 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :610x510 mm bowl depth 200 mm | 1 | each | |
| 269 | 269 | Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern. | 3 | each | |
| 270 | 270 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade | 36 | Sqm. | |
| 271 | 271 | CP Brass fittings Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore | 65 | each | |
| 272 | 272 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore | 20 | each | |
| 273 | 273 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore | 6 | each | |
| 274 | 274 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore | 36 | each | |
| 275 | 275 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms | 7 | each | |
| 276 | 276 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | 8 | each | |
| 277 | 277 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms | 6 | each | |
| 278 | 278 | Providing and fixing unplasticised-PVC pipe approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm | 170 | Rmt | |
| 279 | 279 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 90mm | 90 | Rmt | |
| 280 | 280 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm dia | 170 | metre | |
| 281 | 281 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm | 168 | Metre | |
| 282 | 282 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend | 30 | Each | |
| 283 | 283 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Shoe (Plain) | 30 | Each | |
| 284 | 284 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. | 30 | Each | |
| 285 | 285 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm | 175 | Each | |
| 286 | 286 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes | 238.5 | Rm. | |
| 287 | 287 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 25 mm dia nominal outer dia pipes | 58.5 | Rm. | |
| 288 | 288 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 32 mm dia nominal outer dia pipes | 112 | Rm. | |
| 289 | 289 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Internal work-Exposed on wall 40mm dia nominal bore | 46 | Metre | |
| 290 | 290 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Internal work-Exposed on wall 50mm dia nominal bore | 215 | Metre | |
| 291 | 291 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore | 10 | Each | |
| 292 | 292 | Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore | 4 | Each | |
| 293 | 293 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore | 2 | Nos. | |
| 294 | 294 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].Capcity in Per Liters | 10000 | Ltr. | |
| 295 | 295 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 110mm dia U.P.V.C. SWR pipe | 447 | Rm | |
| 296 | 296 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 90mm dia U.P.V.C. SWR pipe. | 315 | Rm | |
| 297 | 297 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90 mm | 24 | Nos. | |
| 298 | 298 | Providing and fixing terminal guard.110mm | 12 | Nos. | |
| 299 | 299 | Providing and fixing terminal guard. 90mm | 8 | Nos. | |
| 300 | 300 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 110mm bend | 32 | Each | |
| 301 | 301 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 90 mm bend | 35 | Each | |
| 302 | 302 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler110mm | 75 | Each | |
| 303 | 303 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 90mm | 60 | Each | |
| 304 | 304 | Single tee with door 110x110x110 mm | 35 | Each | |
| 305 | 305 | Single tee with door 90x90x90 mm | 25 | Each | |
| 306 | 306 | Providing and fixing clean out plug 110 mm dia. | 32 | Each | |
| 307 | 307 | Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 160mm dia Under floor | 65 | Metre | |
| 308 | 308 | Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete. | 15 | Each |