| Name of Work: Construction of Drug Ware House Dist. Vaccine Store, Attendant Rest Shed, Rest room and stop center (Sakhi) in the campus of DHH, Jajpur for the year 2020-21 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS (PART-I) Dismantling RCC column beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge GF | BI01010001010000000000000515BI0100001112 | 37.38 | cum |
| 2 | 2 | 1st floor | BI01010001010000000000000515BI0100001113 | 22 | cum |
| 3 | 3 | Dismantling brick or stone masonry in lime or cement mortar under 3m height including stacking the useful materials for reuse and removing the debries with 50m lead etc complete as per specification and direction of Engineer in charge. GF | 152.25 | cum | |
| 4 | 4 | 1st floor | 152.25 | cum | |
| 5 | 5 | Dismantling RCC column beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge GF | 26.89 | cum | |
| 6 | 6 | 1st floor | 26.89 | cum | |
| 7 | 7 | Dismantling and removing RCC Chajja, Shelves, fins and parapet including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge GF | 30.9 | sqm | |
| 8 | 8 | 1st floor | 30.9 | sqm | |
| 9 | 9 | Earth wowrk in excavation of foundation trenches in hard soil upto required depth including dressing levelling the bed and deposited the excavated earth away from work site with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge GF | 246.71 | cum | |
| 10 | 10 | Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge | 207.98 | cum | |
| 11 | 11 | Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001114 | 108.24 | cum |
| 12 | 12 | Construction of single under reamed pile foundation of 300mm dia with RCC M-20 using crushed broken hard granite chips of 20mm and down graded with required design with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge 300mm dia 6.0 mtr.long | 172 | each | |
| 13 | 13 | 6.00 mtr. to 8.0 mtr.long (300mm dia pile) | BI01010001010000000000000515BI0100001115 | 172 | each |
| 14 | 14 | RCC work of M-20 Grade with 20mm size crusher broken granite metal mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge. Column base footing | BI01010001010000000000000515BI0100001116 | 165.55 | cum |
| 15 | 15 | Column Superstructure (GF) | BI01010001010000000000000515BI0100001117 | 69.98 | cum |
| 16 | 16 | 1st floor | BI01010001010000000000000515BI0100001118 | 39.38 | cum |
| 17 | 17 | 2nd floor | BI01010001010000000000000515BI0100001119 | 39.38 | cum |
| 18 | 18 | 3rd floor | 39.38 | cum | |
| 19 | 19 | Head room | BI01010001010000000000000515BI0100001120 | 19.19 | cum |
| 20 | 20 | Plinth bend | BI01010001010000000000000515BI0100001121 | 20.39 | cum |
| 21 | 21 | Lintel (GF) | BI01010001010000000000000515BI0100001122 | 7.4 | cum |
| 22 | 22 | 1st floor | BI01010001010000000000000515BI0100001123 | 5.03 | cum |
| 23 | 23 | 2nd floor | BI01010001010000000000000515BI0100001124 | 6.03 | cum |
| 24 | 24 | 3rd floor | 5.03 | cum | |
| 25 | 25 | Floor beam (GF) | BI01010001010000000000000515BI0100001125 | 40.8 | cum |
| 26 | 26 | 1st floor | BI01010001010000000000000515BI0100001126 | 36.49 | cum |
| 27 | 27 | 2nd floor | BI01010001010000000000000515BI0100001127 | 48.32 | cum |
| 28 | 28 | 3rd floor | 36.37 | cum | |
| 29 | 29 | Head room | BI01010001010000000000000515BI0100001128 | 1.55 | cum |
| 30 | 30 | Chajja GF | 20.52 | sqm | |
| 31 | 31 | 1st floor | 19.44 | sqm | |
| 32 | 32 | 2nd floor | 18.36 | sqm | |
| 33 | 33 | 3rd floor | 12.96 | sqm | |
| 34 | 34 | Head room | 3.12 | sqm | |
| 35 | 35 | Staircase (GF) | BI01010001010000000000000515BI0100001132 | 4.54 | cum |
| 36 | 36 | 1st floor | BI01010001010000000000000515BI0100001133 | 3.16 | cum |
| 37 | 37 | 2nd floor | BI01010001010000000000000515BI0100001134 | 3.16 | cum |
| 38 | 38 | 3rd floor | 3.74 | cum | |
| 39 | 39 | Roof slab (GF) | BI01010001010000000000000515BI0100001135 | 59.52 | cum |
| 40 | 40 | 1st floor | BI01010001010000000000000515BI0100001136 | 54.46 | cum |
| 41 | 41 | 2nd floor | BI01010001010000000000000515BI0100001137 | 53.51 | cum |
| 42 | 42 | 3rd floor | 53.06 | cum | |
| 43 | 43 | Head room | BI01010001010000000000000515BI0100001138 | 9.86 | cum |
| 44 | 44 | Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor | BI01010001010000000000000515BI0100001139 | 487.05 | qntl |
| 45 | 45 | 1st floor | BI01010001010000000000000515BI0100001140 | 179.52 | qntl |
| 46 | 46 | 2nd floor | BI01010001010000000000000515BI0100001141 | 197.37 | qntl |
| 47 | 47 | 3rd floor | 178.09 | qntl | |
| 48 | 48 | Head room | BI01010001010000000000000515BI0100001142 | 43.63 | qntl |
| 49 | 49 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. Ground floor in Foundation and Plinth | BI01010001010000000000000515BI0100001143 | 49.56 | cum |
| 50 | 50 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. Ground floor | BI01010001010000000000000515BI0100001144 | 208.13 | cum |
| 51 | 51 | 1st floor | BI01010001010000000000000515BI0100001145 | 92.18 | cum |
| 52 | 52 | 2nd floor | BI01010001010000000000000515BI0100001146 | 106.3 | cum |
| 53 | 53 | 3rd floor | 88.72 | cum | |
| 54 | 54 | Head room | BI01010001010000000000000515BI0100001147 | 19.44 | cum |
| 55 | 55 | Atouter side 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor) | BI01010001010000000000000515BI0100001148 | 606.61 | sqm |
| 56 | 56 | 1st floor | BI01010001010000000000000515BI0100001149 | 298.98 | sqm |
| 57 | 57 | 2nd floor | BI01010001010000000000000515BI0100001150 | 295.88 | sqm |
| 58 | 58 | 3rd floor | 287.57 | sqm | |
| 59 | 59 | Head room | BI01010001010000000000000515BI0100001151 | 66.35 | sqm |
| 60 | 60 | Inner side 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge (GF) | BI01010001010000000000000515BI0100001152 | 1588.38 | sqm |
| 61 | 61 | 1st floor | BI01010001010000000000000515BI0100001153 | 793.02 | sqm |
| 62 | 62 | 2nd floor | BI01010001010000000000000515BI0100001154 | 765.07 | sqm |
| 63 | 63 | 3rd floor | 387.44 | sqm | |
| 64 | 64 | Head room | BI01010001010000000000000515BI0100001155 | 4.46 | sqm |
| 65 | 65 | Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside ceiling surface of brick walls with watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge (GF) | BI01010001010000000000000515BI0100001156 | 461.53 | sqm |
| 66 | 66 | 1st floor | 422.15 | sqm | |
| 67 | 67 | 2nd floor | 414.62 | sqm | |
| 68 | 68 | 3rd floor | 408.33 | sqm | |
| 69 | 69 | Head room | 27 | sqm | |
| 70 | 70 | Providing fitting and fixing of Vitrified tiles in floors of approved make over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge (G,F) | BI01010001010000000000000515BI0100001157 | 442.63 | sqm |
| 71 | 71 | 1st floor | BI01010001010000000000000515BI0100001158 | 408.17 | sqm |
| 72 | 72 | 2nd floor | BI01010001010000000000000515BI0100001159 | 377.19 | sqm |
| 73 | 73 | 3rd floor | 345.09 | sqm | |
| 74 | 74 | Providing fitting and fixing of Chequered tiles in floors of approved make over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge (G,F) | BI01010001010000000000000515BI0100001160 | 61.38 | sqm |
| 75 | 75 | Providing fitting and fixing ofVitrified tiles in dadoos and skirting and risers of approved make over 12mm thick bed of cement mortar(1:3) jointed with neat cement slurry mixed with pigment to match the sades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF | BI01010001010000000000000515BI0100001161 | 82.62 | sqm |
| 76 | 76 | 1st floor | BI01010001010000000000000515BI0100001162 | 67.01 | sqm |
| 77 | 77 | 2nd floor | BI01010001010000000000000515BI0100001163 | 64.13 | sqm |
| 78 | 78 | 3rd floor | 39.16 | sqm | |
| 79 | 79 | Priming one coats with any approved primer to concrete work of approved quality to give an even shade k including sand papering, polishing the surface, cost, conveyances of materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF | BI01010001010000000000000515BI0100001164 | 2673.37 | sqm |
| 80 | 80 | 1st floor Out side | BI01010001010000000000000515BI0100001165 | 298.98 | sqm |
| 81 | 81 | 1st floor Inside | BI01010001010000000000000515BI0100001166 | 1232.02 | sqm |
| 82 | 82 | 2nd floor Out side | BI01010001010000000000000515BI0100001167 | 295.88 | sqm |
| 83 | 83 | 2nd floor Inside | 1179.69 | sqm | |
| 84 | 84 | 3rd floor Out side | 287.57 | sqm | |
| 85 | 85 | 3rd floor Inside | 815.2 | sqm | |
| 86 | 86 | Head room Out side | 66.35 | sqm | |
| 87 | 87 | Head room Inside | 31.46 | sqm | |
| 88 | 88 | Painting two coats over a coat of primer with Plastic Emulsion paint of approved shade and quality with oil bound distemper in interior surface of walls up to any height & in all floors to give an even shade including cost, conveyance, taxes of all materials with labour,T&P etc. complete as per specification and direction of Engineer in charge (GF) | BI01010001010000000000000515BI0100001168 | 2066.76 | sqm |
| 89 | 89 | 1st floor | BI01010001010000000000000515BI0100001169 | 1232.02 | sqm |
| 90 | 90 | 2nd floor | BI01010001010000000000000515BI0100001170 | 1179.69 | sqm |
| 91 | 91 | 3rd floor | 815.2 | sqm | |
| 92 | 92 | Head room | BI01010001010000000000000515BI0100001171 | 31.46 | sqm |
| 93 | 93 | Painting two coats with anti-fungal resistance Weather Seal Coat of approved shade over a coat of (water bound) wall primer upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge GF | BI01010001010000000000000515BI0100001172 | 606.61 | sqm |
| 94 | 94 | 1st floor | BI01010001010000000000000515BI0100001173 | 298.98 | sqm |
| 95 | 95 | 2nd floor | BI01010001010000000000000515BI0100001174 | 295.88 | sqm |
| 96 | 96 | 3rd floor | 287.57 | sqm | |
| 97 | 97 | Head room | BI01010001010000000000000515BI0100001175 | 66.35 | sqm |
| 98 | 98 | Supplying, fitting & fixing in all floors of M.S.grills for door and window and gates, with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials labour, cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost For Door | BI01010001010000000000000515BI0100001176 | 1010.79 | kg |
| 99 | 99 | For Window | BI01010001010000000000000515BI0100001177 | 4162.18 | kg |
| 100 | 100 | Providing, Fitting & Fixing of Stainless steel of 304 grade in hand railing of 50mm outer diameter of 2mm thick of approved Quality & Specification with balustrade of size 32mmX32mmX2mm square pipes in rows including Cost of all Materials, Labour for fabrication, buffing & polishing, cost of all fixtures etc. Complete and as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001182 | 693.77 | kg |
| 101 | 101 | Supplying fitting and fixing of UPVC (FENESTA/ NCL/VEKALTD casement window with top fixed 60 series duly manufactured using UPVC reinforced profile of 60mmx55mmx.25mm for outer frame 74mmx60mmx2.25mm for casement Door sash profile and 74mmx60mmx2.5mm mullian profile capable of mounting single glazing system etc complete as per direction and specification of Engineer in charge | BI01010001010000000000000515BI0100001183 | 98.28 | sqm |
| 102 | 102 | Supplying fitting and fixing of UPVC (FENESTA/ NCL/VEKALTD casement window with top fixed 60 series duly manufactured using UPVC reinforced profile of 60mmx55mmx 25mm for outer frame 75mmx60mmx2.25mm for casement window sash profile and 74mmx60mmx2.5mm mullian profile capable of mounting single glazing system etc complete as per direction and specification of Engineer in charge | 171.92 | sqm | |
| 103 | 103 | Painting two coats over a coat of primer with Synthetiic Enamel paint of approved shade and quality to wood/iron works including sand papering, polishing the surface in all floors to give an even shade including cost, conveyance, taxes of all materials with labour,T&P etc. complete as per specification and direction of Engineer in charge (GF) | 198.76 | sqm | |
| 104 | 104 | 2.5cm thick grading concrete of proportion (1:2:2) over roof slab using 4.7mm size chips of approved quality including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge 3rd flioor | BI01010001010000000000000515BI0100001184 | 484.05 | sqm |
| 105 | 105 | Head room | 46.67 | sqm | |
| 106 | 106 | E.I.Works:-Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 6Amp, 250V Modular switch ISI marked and ceiling rose ISI marked mounted on metal box having front Modular cover of suitable size, metal box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection.(Make of wire-Finolex/Polycab/V-Guard)(Make of Modular Switch- Anchor Roma/ L&T/ Crabtree/Legrand) Group-A -L.P- 206 F.P- C.B.P- | BI01010001010000000000000515BI0100001185 | 110 | Nos |
| 107 | 107 | Group-B L.P- 308 F.P- 74 C.B.P- | BI01010001010000000000000515BI0100001186 | 133 | Nos |
| 108 | 108 | Group-C L.P- 543 F.P- 419 C.B.P- | BI01010001010000000000000515BI0100001187 | 88 | Nos |
| 109 | 109 | Group control of point in Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- RR KABEL/POLYCAB/HAVELLS with 20 mm dia PVC flexible non metallic conduit Make-AKG/KINJAL/POLYCAB with 6A modular type switch ISI marked Make-Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision),and ceiling rose ISI marked Make- Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision), of modular type G.I box with cover Make-Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision), of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit) | BI01010001010000000000000515BI0100001188 | 18 | Nos |
| 110 | 110 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision), | BI01010001010000000000000515BI0100001189 | 35 | Nos |
| 111 | 111 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision), | BI01010001010000000000000515BI0100001190 | 99 | Nos |
| 112 | 112 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision),(For equipement power) | BI01010001010000000000000515BI0100001191 | 35 | Nos |
| 113 | 113 | Supplying,fixing of 2x16A Plug on the separate board with complete fitting by 02 no of 16A switch & socket(modular type),6A modular switch with socket with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision),(For equipement power) | BI01010001010000000000000515BI0100001192 | 7 | Nos |
| 114 | 114 | Recessed wiring to submain in the following sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FRLS PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex//Polycab/Havells/V-Guard//HPL)2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20mm Dia Conduit Extra Lead. In 20 mm dia non metallic heavy duty flexible conduit\n | BI01010001010000000000000515BI0100001193 | 311 | Mtr |
| 115 | 115 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm in 20mm Dia ConduitFrom MCB to Switch Board in 20 mm dia non metallic heavy duty flexible conduit. | BI01010001010000000000000515BI0100001194 | 444 | Mtr |
| 116 | 116 | 4 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallic heavy duty flexible conduit | BI01010001010000000000000515BI0100001195 | 299 | Mtr |
| 117 | 117 | 2 X 4 sq.mm +1 X 2.5 sq.mm in 20mm Dia Conduit to AC Point and Multipurpose Board in 20 mm dia non metallic heavy duty flexible conduit . | BI01010001010000000000000515BI0100001196 | 321 | Mtr |
| 118 | 118 | 4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty flexible conduit | BI01010001010000000000000515BI0100001197 | 188 | Mtr |
| 119 | 119 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit . | BI01010001010000000000000515BI0100001198 | 25 | Mtr |
| 120 | 120 | 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty flexible conduit. | BI01010001010000000000000515BI0100001199 | 48 | Mtr |
| 121 | 121 | 4 X 10 sq.mm + 2 X 4 sq.mm in 32mm Dia Conduit From Panel to TPN Light Distribution Board in 32 mm dia non metallic heavy duty flexible conduit . | BI01010001010000000000000515BI0100001200 | 121 | Mtr |
| 122 | 122 | 4 X 16 sq.mm + 2 X 10 sq mm in 40 mm Dia Conduit From Panel to TPN Power Distribution Board in 40 mm dia non metallic heavy duty flexible conduit. | BI01010001010000000000000515BI0100001201 | 88 | Mtr |
| 123 | 123 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Schneider(Clipsal X)/legrand( Arteor) /Panasonic (Vision), make | BI01010001010000000000000515BI0100001202 | 6 | Nos |
| 124 | 124 | Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Schneider/Hager/Siemens make | BI01010001010000000000000515BI0100001203 | 4 | Nos |
| 125 | 125 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. MAKE-Legrand/Siemens/Schneider 4 moudle(125mmx75mm) | BI01010001010000000000000515BI0100001204 | 15 | Nos |
| 126 | 126 | 1 moudle(75mmx75mm) | BI01010001010000000000000515BI0100001205 | 12 | Nos |
| 127 | 127 | 12 moudle(200mmx150mm) | BI01010001010000000000000515BI0100001206 | 8 | Nos |
| 128 | 128 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE KINJAL/ AKG/Anchor20MM | BI01010001010000000000000515BI0100001207 | 33 | mtrs |
| 129 | 129 | 25 MM | BI01010001010000000000000515BI0100001208 | 25 | mtrs |
| 130 | 130 | Supply and fixing modular type indicator on the existing switch box/cover of Anchor make as required as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001209 | 5 | Nos |
| 131 | 131 | Supplying and installation of AC starter Modular type,Schneider/Siemens make or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge . | BI01010001010000000000000515BI0100001210 | 12 | Nos |
| 132 | 132 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover of Anchor make .as required as per direction of Engg.-in-Charge | BI01010001010000000000000515BI0100001211 | 4 | Nos |
| 133 | 133 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . | BI01010001010000000000000515BI0100001212 | 18 | EACH |
| 134 | 134 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (Make-Havells/almonard/cromptron make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001213 | 12 | Nos |
| 135 | 135 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers (Make-Havells/almonard/cromptron make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge | BI01010001010000000000000515BI0100001214 | 4 | Nos |
| 136 | 136 | Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan of Havells velocity/ CROMPTRON JURA Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) as required as per direction of Engg.-in-Charge | BI01010001010000000000000515BI0100001215 | 18 | Nos |
| 137 | 137 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of Havells velocity/CROMPTRON JURA Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge .(With fan Regulator) | BI01010001010000000000000515BI0100001216 | 66 | Nos |
| 138 | 138 | Supplying and fixing of Energy efficient Recess mounted LED luminaire made up of powder coated CRCA housing having Perforated Center panel of 600 X 600 mm size with sytem power consumption of 31W and system lumens output not less than 3600 lumens @ 210 mA , 50K burning hrs @L70B50 with non yellowing Highly efficient molded PC diffusers for better light transmission and pure effect,with High luminous flux LEDs for better light output,CRI not less than 80 (SDCM<5 & R9>0) , CCT of 4000K/5700K/6500K, THD less than 10%, Ripple <5% for anti-flicker , Inbuilt 4kV Surge Protection , over-voltage protection @320V cut-off with auto-restart , class B serviecability complete with electronic driver and all other accessories suitable for operation on 140V-270V AC , 50 Hz supply , UGR 19 , WELL V2.0 & LEED V4.0 , future provision of controls such as DALI / IA / POE etc. , BIS approved luminaire & BIS approved potted driver of same make . LM79,LM80,TTC & IES files from valid NABL accredited LAB as required as per direction of Engg.-in-Charge (Make: PHILIPS model no: RC480B LED30S/865 W60L60 PSU WH or similar of LT / XAL / Zumtobel make or equivalant make) | BI01010001010000000000000515BI0100001217 | 24 | No |
| 139 | 139 | Supplying and fixing of Energy efficient surface mounted LED downlight with white powder coated , Al / PC housing ,with high transmititivity,non-yellowing PC diffuser, 30K burning hrs with wattage not more than 18 watt and lumen output not less than 2000 lumens ,CRI not less than 80(SDCM<5),CCT of 4000 K/6500 K , THD<30%, with electronic driver and all other accessories suitable for operation , on 140V - 270V AC , 50 Hz supply as required as per direction of Engg.-in-Charge. LM79,LM80 & IES files from Valid NABL accreditied LAB ( Make : PHILIPS Model No:SM251C LED15S- 6500 PSU WH similar make of LT/XAL/Zumtobel) | BI01010001010000000000000515BI0100001218 | 26 | Nos |
| 140 | 140 | Supplying and fixing of Energy efficient recess mounted LED luminaire with white powder coated , CRCA housing ,with high transmititivity,non-yellowing PC diffuser , with wattage not more than 18 watt and system efficacy not less than 2000 lumens/watt @ driving current of max. 75mA, 50K burning hrs @ L70B50 , CRI not less than 80 (SDCM<5 & R9>0),CCT of 4000K/5700K/6500 degree K,THD less than 10%, ripple<5% , electrical insulation class 1 & Servicability of Class B , 120 deg beam angle , with electronic driver having future provision of DALI , IA , POE and all other accessories suitable for operation on 230 V, 50 Hz supply . BIS approved luminaire & BIS approved potted driver of same make . LM79,LM80,IES files & TTC from valid NABL accredited LAB as required as per direction of Engg.-in-Charge. (Similar to PHILIPS Model No:BN308C LED20S-6500 L120 PSU WH or similar make of LT/Zumtobel/XAL) . | BI01010001010000000000000515BI0100001219 | 21 | Nos |
| 141 | 141 | SITC of Sleek LED 22 watt TUBE light fitting with extruded Aluminium housing,High optically efficient PC diffuser with 210gm weight , system efficacy @ 220 lm/W , 2.5 kV Surge Protection , input current range of 88 mA to 98 mA . THD<20% . above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.\n( Make : PHILIPS Model No:BN 021 LED22S- 6500 PSU GR or similar make of LT/Trilux/Zumtobel) . Detailed specs as per annexure | BI01010001010000000000000515BI0100001220 | 120 | Nos |
| 142 | 142 | SITC of Sleek LED 12 watt mirror light fitting with extruded Aluminium housing,High optically efficient PC diffuser with 210gm weight , system efficacy @ 100 lm/W , 2.5 kV Surge Protection , input current range of 88 mA to 98 mA . THD<20% . above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.\n( Make : PHILIPS Model No:BN 021 LED12S- 6500 PSU GR or similar make of LT/Trilux/Zumtobel) . Detailed specs as per annexure | BI01010001010000000000000515BI0100001221 | 12 | Nos |
| 143 | 143 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .\n(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. | BI01010001010000000000000515BI0100001222 | 111 | Nos |
| 144 | 144 | BDBS,DB,AC DB,FLOOR PANELS,MCBS-Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) make-(Make-Legrand Ekinox3 ETPN/Scnider Acti 9). Legrand/SCHNEIDER/Siemens make, or any other equivallent A catagories reputed make ISI marked as approved as per direction of Engg.-in-Charge. 4 Way(8+12) Way TPN MCB DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,,UPS ICU AC INDOOR,3-PH,POWER LOAD) | BI01010001010000000000000515BI0100001223 | 8 | Nos |
| 145 | 145 | Supply and fixing of 12 way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (make-Legrand Ekinox3 ETPN/Scnider Acti 9./L&T)(ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) | BI01010001010000000000000515BI0100001224 | 8 | Nos |
| 146 | 146 | 4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION medical /AC ODU as outdoor type)) | BI01010001010000000000000515BI0100001225 | 4 | Nos |
| 147 | 147 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Legrand/Snheider/Siemens make or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001226 | 220 | Nos |
| 148 | 148 | Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA Legrand/Snheider/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . | BI01010001010000000000000515BI0100001227 | 6 | Nos |
| 149 | 149 | Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Legrand/Snheider/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001228 | 4 | Nos |
| 150 | 150 | Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Legrand/Snheider/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001229 | 4 | Nos |
| 151 | 151 | Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Legrand/Snheider/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections. | BI01010001010000000000000515BI0100001230 | 1 | Nos |
| 152 | 152 | Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Legrand/Snheider/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections.(for power BDB & AC ODU, 8 way TPN BDB IC) | BI01010001010000000000000515BI0100001231 | 2 | Nos |
| 153 | 153 | S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001232 | 2 | Nos |
| 154 | 154 | S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001233 | 2 | Nos |
| 155 | 155 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001234 | 199 | Mtr |
| 156 | 156 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001235 | 21 | Mtr |
| 157 | 157 | Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001236 | 2 | Mtr |
| 158 | 158 | Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB/HAVELLS/KEI of following size cables as per direction of Engg.-in-Charge. 3.5core x 185 sq mm (under ground including excavation & refilling)(Substation to main panel) INCOMMER) | BI01010001010000000000000515BI0100001237 | 51 | Mtr |
| 159 | 159 | 3.5core x 150 sq mm (under ground including excavation & refilling)(MAIN PANEL to floor power panel 2f) | BI01010001010000000000000515BI0100001238 | 15 | Mtr |
| 160 | 160 | Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS of following size cables as per direction of Engg.-in-Charge. 3.5core x 70 sq mm ( FOR FDB P GF) | BI01010001010000000000000515BI0100001239 | 25 | Mtr |
| 161 | 161 | 4core x 16 sq mm (MDB TO FDBL ALL FLOOR) | BI01010001010000000000000515BI0100001240 | 33 | Mtr |
| 162 | 162 | 4 core x 4 sq mm (for small power/freezer) | BI01010001010000000000000515BI0100001241 | 33 | Mtr |
| 163 | 163 | 3.5core x 35 sq mm (To power FDB 2F,3F) | BI01010001010000000000000515BI0100001242 | 33 | Mtr |
| 164 | 164 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001243 | 10 | Mtr |
| 165 | 165 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001244 | 10 | Mtr |
| 166 | 166 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001245 | 45 | Mtr |
| 167 | 167 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001246 | 2 | Mtr |
| 168 | 168 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001247 | 33 | Mtr |
| 169 | 169 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001248 | 29 | Mtr |
| 170 | 170 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001249 | 29 | Mtr |
| 171 | 171 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001250 | 8 | Mtr |
| 172 | 172 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001251 | 12 | Mtr |
| 173 | 173 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. | BI01010001010000000000000515BI0100001252 | 12 | Mtr |
| 174 | 174 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x185 sq mm | BI01010001010000000000000515BI0100001253 | 4 | Nos |
| 175 | 175 | 3.5 core x150 sq mm | BI01010001010000000000000515BI0100001254 | 2 | Nos |
| 176 | 176 | 4 core x16sq mm | BI01010001010000000000000515BI0100001255 | 6 | Nos |
| 177 | 177 | 3.5 core x35 sq mm | BI01010001010000000000000515BI0100001256 | 6 | Nos |
| 178 | 178 | 3.5 core x70 sq mm | BI01010001010000000000000515BI0100001257 | 4 | Nos |
| 179 | 179 | Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50mm DIA | BI01010001010000000000000515BI0100001258 | 5 | mtrs |
| 180 | 180 | 80 mm dia | BI01010001010000000000000515BI0100001259 | 5 | mtrs |
| 181 | 181 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200mm dia | BI01010001010000000000000515BI0100001260 | 40 | mtrs |
| 182 | 182 | MAIN PANEL - S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001261 | 1 | Set |
| 183 | 183 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001262 | 1 | Set |
| 184 | 184 | FLOOR PANEL POWER 2F,3FS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR Each floor power )as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001263 | 2 | Set |
| 185 | 185 | FLOOR PANEL LIGHT 2F,3F,1F-S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR Each floor power )as per direction of Engg.-in-Charge. | BI01010001010000000000000515BI0100001264 | 3 | Set |
| 186 | 186 | 10 PASSENGER LIFT WITH WIRRING-Design Supply, Installation, Testing & Commissioning and putting into operation with compelete inspection by concerned electrical inspector, Director Factory and Boilers, Odisha with proper testing certificate and final testing of Automatic Lift compelte with all standard equipments accessories and control equipments as per Manufacturer's Design and as per CPWD /OPWD specification (Part - III Lifts) 1981 with valid lisence for installation and fulfilling following requirements on turnkey basis as per direction of Engg.-in-Charge. HOSPITAL PASSENGER LIFT ,MAKE-KONE /OTIS/JUNCTION\nType: PASSENGER LIFT \nLoad: 10 PASSENGER(650KG)\nSpeed: 1.0-1.25 Meter Per Second.\nControl: Variable voltage with variable frequency\nOperation: Microsprocessor based simplex collective selective with / without Lift Attendant.\nTotal Rise: About 10 Meters.\nLandings: For All on same side. \nFloors Served: G, 1,2,3,TERRACE\nSignals: Digital Car Position Indicator, Car Travel direction Indicator in Car & at all Landings. \nLift Shaft Size: About as 10 passenger hospital lift standard, finished with Plaster. \nLift Car Size: About hospital lift standard. \nCar Entrance: Clear Opening hospital lift standard high Protected with Car Door.\nLanding Entrance: Clear Opening hospital lift standard high Protected with Landing Door.\nCar Door: Stainless with front glass to transparent Two Panel Center opening flush type.outer visible. \nLanding Door: Mild Steel Two Panel Center opening flush type P. \nDoor Operation: Automatic Electric Power operated Door with in infrared protection. \nCar Interior: Stainless Steel Panel with Hair line finish on all sides.\nCar Ceiling & Lighting: Fluorescent Lighting Concealed by suspended false ceiling with plain acrylic diffiuser. The frame of suspended false ceiling shall be of powder coated Aluminum. \nCar Ventilation: Pressure Fan with anodized Aluminum Grill.\nEmergencing Lighting in Car: Battery operated Emergencing Lighting in the Lift Car. \nIntercom System: Battery operated intercom system in Lift Car, Machine Room and Control Room.\nEmergencing Alarm: Battery operated Alarm Bell System in Lift Car and Control Room.\nPosition of Machine Room: Directly above the Lift Shaft.\nElectric Power Supply: AC 415 Volt 3 Phase 50 Hz terminated in Machine Room.\nOTHER SPECIAL PROVISIONS\n• VVVF CONTROLLER\n• AUTOMATICE RESCUE DEVICE (ARD)\n• EMERGENCY LIGHT AND BATARY OPERATED ALARAM BELL\n• DOT MATRICKX SEVEN SIGMENT DIGITAL POSITION INDICATORS\n• FIRE RATED DOOR FOR 1 HOUR\n• 3 WAY INTER COM/PRESS AND SPEAK BUTTON WITH HAND SET\n• FLOOR ANNUNCIATOR WITH MUSIC\n• INFRA RED SCREEN\n• OVER LOAD WARNING INDICATOR\n• BRAILLE BUTTONS\n• FREE SERVICE FOR 2 YEARS\n• PIT LADER\n• FULL CAR HEIGH CAR FIXTURE ARRIVAL CHIME\n• PROVISION FOR CC CEMARA WITH INSTRUEMENT \nFire Man Switch: Fire Man Switch at Main Landing Terminal. | BI01010001010000000000000515BI0100001266 | 1 | JOB |
| 187 | 187 | Supply, Installation, Testing & Commissioning and putting into operation and final testing of Automatic Lift compelte with all standard equipments accessories and control equipments as per Manufacturer's Design and as per OPWD specification (Part - III Lifts) 1981 and fulfilling following requirements on turnkey basis. \nType: STRETCHER Lift.\nLoad: All types of STRETCHER\nSpeed: 1.0 Meter Per Second.\nControl: AC2.\nOperation: Microsprocessor based simplex collective selective with / without Lift Attendant.\nTotal Rise: About 15 Meters.\nLandings: 4 All on same side.\nFloors Served: G,1,2,3 & TF\nSignals: Digital Car Position Indicator, Car Travel direction Indicator in Car & at all Landings.\nLift Shaft Size: About 3000mm Width X3000mm Depth, finished with Plaster.\nLift Car inside Size: AS PER STANDARD\nEntrance coll. gate: 1300mm width\nLift well: 2400mm widthx2300mm Length\nCar Door: Stainless Two Panel Center opening flush type.\nLanding Door: Mild Steel Two Panel Center opening flush type P.\nDoor Operation: Automatic Electric Power operated Door with in infrared protection.\nCar Interior: Stainless Steel Panel with Hair line finish on all sides.\nCar Floor: Hard Wood covered with PVC / Marblex Tiles.\nCar Ceiling & Lighting: Fluorescent Lighting Concealed by suspended false ceiling with plain acrylic diffiuser. The frame of suspended false ceiling shall be of powder coated Aluminum.\nCar Ventilation: Pressure Fan with anodized Aluminum Grill.\nEmergencing Lighting in Car: Battery operated Emergencing Lighting in the Lift Car.\nIntercom System: Battery operated intercom system in Lift Car, Machine Room and Control Room.\nEmergencing Alarm: Battery operated Alarm Bell System in Lift Car and Control Room.\nPosition of Machine Room: Directly above the Lift Shaft.\nEelctric Power Supply: AC 415 Volt 3 Phase 50 Hz termianted in Machine Room.\nFire Man Switch: Fire Man Switch at Main Landing Terminal. | BI01010001010000000000000515BI0100001267 | 1 | JOB |
| 188 | 188 | 80mm nominal dia | BI01010001010000000000000515BI0100001268 | 88 | Rmt |
| 189 | 189 | 32mm nominal dia | BI01010001010000000000000515BI0100001269 | 88 | Rmt |
| 190 | 190 | 25mm nominal dia | BI01010001010000000000000515BI0100001270 | 88 | Rmt |
| 191 | 191 | Supplying, Installing, testing and commissioning CI butterfly valves ( PN 16) as per BS 5155 slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.\n100mm nominal dia | BI01010001010000000000000515BI0100001271 | 4 | Nos. |
| 192 | 192 | 50mm nominal dia | BI01010001010000000000000515BI0100001273 | 4 | Nos. |
| 193 | 193 | Supplying, installing, testing and commissioning of hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete. Alarm valve shall be UL Listed / FM approved. 100mm dia | BI01010001010000000000000515BI0100001274 | 1 | Nos. |
| 194 | 194 | Supplying, installing, testing and commissioning conventional Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating,K 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed / FM approved with Chrome finished.Upright Sprinkler | BI01010001010000000000000515BI0100001276 | 35 | Nos |
| 195 | 195 | Pendant Sprinkler | BI01010001010000000000000515BI0100001278 | 75 | Nos |
| 196 | 196 | Supplying, installing, testing and commissioning of Gun metal /Brass Forged chrome finished Ball valves with fittings of screwed end type.50mm dia.(Drainage ) | BI01010001010000000000000515BI0100001279 | 12 | Nos. |
| 197 | 197 | Supplying, installing, testing and commissioning of Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. | BI01010001010000000000000515BI0100001280 | 12 | Nos. |
| 198 | 198 | Supplying, installing, testing and commissioning of flow switch (water flow detector) , Flow switch shall have a paddle made of flexible material of the widthto fit within the pipe bore. The terminal box shall be mounted over the paddle/ pipe through a connecting socket.The switch shall be potential free in either NO or NC position as required. The switch shall be able to trip and make/ break contact on the operation of a sprinkler head. The terminal box shall have connections for wiring to the Fire alarm panel. The seat shall be of stainless steel. The flow switch shall have IP: 55 protection.100mm dia | BI01010001010000000000000515BI0100001281 | 1 | Nos. |
| 199 | 199 | CCTV SERVEYLANCE-Network Video Recorder of 32Channels with 4 HDD Support, with maximum resolution support of 12 mp Input with 256 mpbs incoming and 256 mbps outgoing bandwidth | BI01010001010000000000000515BI0100001282 | 1 | Nos. |
| 200 | 200 | 4 MP ColorVu Fixed Turret Network Camera | BI01010001010000000000000515BI0100001283 | 2 | Nos. |
| 201 | 201 | 6 TB Surveillance Hard Disk | BI01010001010000000000000515BI0100001284 | 1 | Nos. |
| 202 | 202 | 32\" LED Monitor with 3 Nos. of HDMI Port. Full HD. Make Samsung/LG | BI01010001010000000000000515BI0100001285 | 1 | Nos. |
| 203 | 203 | Supply and Installation of 26 Port 10/100/1000 Mbps Poe Ethernet Switch | BI01010001010000000000000515BI0100001286 | 1 | Nos. |
| 204 | 204 | Supply and laying of Cat6 STP Cable in ISI marked Medium PVC Pipe using Saddle and Screw with all accessories per running metre of cable used. | BI01010001010000000000000515BI0100001287 | 333 | Nos. |
| 205 | 205 | Supply and laying of 3 Core 1 sq.mm. power Cable in ISI marked Medium PVC Pipe using Saddle and Screw with all accessories per running metre of cable used. | BI01010001010000000000000515BI0100001288 | 321 | Nos. |
| 206 | 206 | Supply and installation of 1x5 Amps Switch & Socket with Surface mount Box | BI01010001010000000000000515BI0100001289 | 3 | Nos. |
| 207 | 207 | Supply and fixing of 6U Val Rack with 2 nos. cooling fan, power manager, cable manager. | BI01010001010000000000000515BI0100001290 | 1 | Nos. |
| 208 | 208 | UPVC Square 4 \" x 4\" Rigid PVC Box | BI01010001010000000000000515BI0100001291 | 20 | Nos. |
| 209 | 209 | 10 Meters Long HDMI Cable make Belkin / MX | BI01010001010000000000000515BI0100001292 | 1 | Nos. |
| 210 | 210 | 1000 VA Sine Wave Inverter | BI01010001010000000000000515BI0100001293 | 1 | Nos. |
| 211 | 211 | 150Ah Tall Tubular Battery | BI01010001010000000000000515BI0100001294 | 1 | Nos. |
| 212 | 212 | UPS PVC Rack Complete | BI01010001010000000000000515BI0100001295 | 1 | Nos. |
| 213 | 213 | System installation, testing and commissioing charges. | BI01010001010000000000000515BI0100001297 | 1 | Nos. |
| 214 | 214 | EPABX System with 2 P&T and 14 Extensions with Power Supply | BI01010001010000000000000515BI0100001298 | 1 | Nos. |
| 215 | 215 | 30 Port Junction Box make Custom | BI01010001010000000000000515BI0100001299 | 1 | Nos. |
| 216 | 216 | Beetel M-51 Caller ID Telephone | BI01010001010000000000000515BI0100001300 | 6 | Nos. |
| 217 | 217 | RJ11 Modular Complete | BI01010001010000000000000515BI0100001301 | 6 | Nos. |
| 218 | 218 | Ligthening Protector | BI01010001010000000000000515BI0100001302 | 6 | Nos. |
| 219 | 219 | Supply and Installation of 4 Core 0.5 mm Telephone Cable in concealed manner using rigid PVC Pipe / Casing Caping per running metre of cable used. | BI01010001010000000000000515BI0100001303 | 188 | Nos. |
| 220 | 220 | System installation, testing and commissioning charges per extension | BI01010001010000000000000515BI0100001304 | 1 | Nos. |
| 221 | 221 | 24 Port Gigabit Ethenet Unmanaged Switch. | BI01010001010000000000000515BI0100001305 | 1 | Nos. |
| 222 | 222 | Cat 6 Patch Panel. | BI01010001010000000000000515BI0100001306 | 1 | Nos. |
| 223 | 223 | Cat 6 Patch Cord 1 Mtr. | BI01010001010000000000000515BI0100001307 | 6 | Nos. |
| 224 | 224 | Supply and Installation of Cat 6 Cable in concealed manner using rigid PVC Pipe / Casing Caping per running metre of cable used. | BI01010001010000000000000515BI0100001308 | 121 | Nos. |
| 225 | 225 | Information Outlet Cat 6 Complete. | BI01010001010000000000000515BI0100001309 | 6 | Nos. |
| 226 | 226 | 6 U Rack with Cooling Fan. | BI01010001010000000000000515BI0100001310 | 1 | Nos. |
| 227 | 227 | System installation, testing and commissioning charges. | BI01010001010000000000000515BI0100001311 | 1 | Nos. |
| 228 | 228 | P.H.Works:-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.20mm dia CPVC pipe \n20mm dia C- PVC pipe In ground floor | BI01010001010000000000000515BI0100001312 | 20 | mtr |
| 229 | 229 | In First floor | BI01010001010000000000000515BI0100001313 | 20 | Mtr |
| 230 | 230 | In 2nd floor | BI01010001010000000000000515BI0100001314 | 30 | Mtrs |
| 231 | 231 | In 3rd floor | BI01010001010000000000000515BI0100001315 | 40 | mtrs |
| 232 | 232 | 25mm dia C-PVC pipe ground floor | BI01010001010000000000000515BI0100001316 | 25 | Mtr |
| 233 | 233 | In First floor | BI01010001010000000000000515BI0100001317 | 25 | Mtr |
| 234 | 234 | In 2nd floor | BI01010001010000000000000515BI0100001318 | 50 | Mtr |
| 235 | 235 | In 3rd floor | BI01010001010000000000000515BI0100001319 | 50 | Mtr |
| 236 | 236 | 32mm dia C-PVC Pipe in ground floor | BI01010001010000000000000515BI0100001320 | 20 | Mtr |
| 237 | 237 | In First floor | BI01010001010000000000000515BI0100001321 | 20 | Mtr |
| 238 | 238 | In 2nd floor | BI01010001010000000000000515BI0100001322 | 30 | Mtr |
| 239 | 239 | In 3rd floor | BI01010001010000000000000515BI0100001323 | 40 | mtr |
| 240 | 240 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.25mm dia PVC ASTM pipe (sch-80) Ground floor\n | BI01010001010000000000000515BI0100001324 | 35 | mtr |
| 241 | 241 | In Ist floor 25mm dia PVC ASTM pipe (sch-80) | BI01010001010000000000000515BI0100001325 | 45 | mtr |
| 242 | 242 | In 2nd floor 25mm dia PVC ASTM pipe (sch-80) | BI01010001010000000000000515BI0100001326 | 25 | mtr |
| 243 | 243 | In Third floor 25mm dia PVC ASTM pipe (sch-80) | BI01010001010000000000000515BI0100001327 | 45 | mtr |
| 244 | 244 | 40mm dia PVC ASTM pipe In G.F | BI01010001010000000000000515BI0100001328 | 120 | mtr |
| 245 | 245 | In first floor | BI01010001010000000000000515BI0100001329 | 35 | mtr |
| 246 | 246 | In 2nd floor | BI01010001010000000000000515BI0100001330 | 45 | mtr |
| 247 | 247 | In 3rd floor | BI01010001010000000000000515BI0100001331 | 95 | mtr |
| 248 | 248 | In fourth floor over roof | BI01010001010000000000000515BI0100001332 | 65 | mtr |
| 249 | 249 | 50 mm dia PVC ASTM pipe (sch-80) over roof 4th floor | BI01010001010000000000000515BI0100001333 | 75 | mtr |
| 250 | 250 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall | BI01010001010000000000000515BI0100001334 | 35 | Each |
| 251 | 251 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.In ground floor | BI01010001010000000000000515BI0100001335 | 15 | Each |
| 252 | 252 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In ground floor to 3rd.floor | BI01010001010000000000000515BI0100001336 | 370 | mtr |
| 253 | 253 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15mm dia CP bib cock CON-CHR-037KN(Jaquar make ) | BI01010001010000000000000515BI0100001337 | 9 | Each |
| 254 | 254 | 15 mm dia CP two way Bib cock CON-CHR-041KN(Jaquar make ) | BI01010001010000000000000515BI0100001338 | 10 | Each |
| 255 | 255 | 15mm dia CP Health foucet (Con-ALD-CHC-573 Jaquar make) | BI01010001010000000000000515BI0100001339 | 10 | Each |
| 256 | 256 | 15 mm dia CP Long body Bib cock( CON-CHR-107KN Jaquar make ) | BI01010001010000000000000515BI0100001340 | 17 | Each |
| 257 | 257 | 15mm dia CP angle stop cock(CON-BCH-053KN Jaquar ) Make | BI01010001010000000000000515BI0100001341 | 36 | Each |
| 258 | 258 | 20mm dia CP concealed stop cock(CON-CHR-069KN Jaquar ) Make | BI01010001010000000000000515BI0100001342 | 13 | Each |
| 259 | 259 | 15mm dia C.P. bottle trap ALD-CHR-769L300X190 Jaquar make | BI01010001010000000000000515BI0100001343 | 14 | Each |
| 260 | 260 | 15 mm dia CP pillar cock auto closing system(Jaquar)-PRS-CHR-031 | BI01010001010000000000000515BI0100001344 | 10 | Each |
| 261 | 261 | 15mm dia pvc connection pipe | BI01010001010000000000000515BI0100001345 | 10 | Each |
| 262 | 262 | 25mm dia Brass full way valve (Shakti Make) | BI01010001010000000000000515BI0100001346 | 4 | Each |
| 263 | 263 | 40mm dia Brass full way Valve (Shakti Make) | BI01010001010000000000000515BI0100001347 | 10 | Each |
| 264 | 264 | 50mm dia Brass full way Valve ( Shakti make ) | BI01010001010000000000000515BI0100001348 | 2 | Each |
| 265 | 265 | 15mm dia CP flange | BI01010001010000000000000515BI0100001349 | 78 | Each |
| 266 | 266 | 15mm dia CP extension piece | BI01010001010000000000000515BI0100001350 | 78 | Each |
| 267 | 267 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge 15mm dia CP revolving shower ( Plaza make ) | BI01010001010000000000000515BI0100001351 | 13 | Each |
| 268 | 268 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white | BI01010001010000000000000515BI0100001352 | 18 | Each |
| 269 | 269 | Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00 X1.50m- In 4th floor.-Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001353 | 16.76 | Cum |
| 270 | 270 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. | BI01010001010000000000000515BI0100001354 | 16.76 | Qtl |
| 271 | 271 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. | BI01010001010000000000000515BI0100001355 | 46.25 | sqm |
| 272 | 272 | RCC Beam, Column, wall etc | BI01010001010000000000000515BI0100001356 | 92.45 | sqm |
| 273 | 273 | Supplying all materials, labour,T&P and providing 12mm thick cement plasster (1:3) over CC work including watering curring and conveyance of all materials to site. | BI01010001010000000000000515BI0100001357 | 52.2 | sqm |
| 274 | 274 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. | BI01010001010000000000000515BI0100001358 | 52.2 | sqm |
| 275 | 275 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.\n | BI01010001010000000000000515BI0100001359 | 60 | Kg |
| 276 | 276 | Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge | BI01010001010000000000000515BI0100001360 | 40 | Kg |
| 277 | 277 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm OPEN well submersible pump(Kirloskar make) | BI01010001010000000000000515BI0100001361 | 2 | Each |
| 278 | 278 | DOL Control panel | BI01010001010000000000000515BI0100001362 | 2 | Each |
| 279 | 279 | 2.50sqmm flat cable | BI01010001010000000000000515BI0100001363 | 120 | Mtr |
| 280 | 280 | 20mm dia rigid UPVC pipes | BI01010001010000000000000515BI0100001364 | 120 | Mtr |
| 281 | 281 | Labour charges for lowering including transportation | BI01010001010000000000000515BI0100001365 | 2 | Each |
| 282 | 282 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe(Ashirbad / Supreeme ) | BI01010001010000000000000515BI0100001366 | 540 | Mtr |
| 283 | 283 | 110mm U-PVC door cross tee | BI01010001010000000000000515BI0100001367 | 12 | Each |
| 284 | 284 | 110mm U-PVC door tee | BI01010001010000000000000515BI0100001368 | 36 | Each |
| 285 | 285 | 110mm U-PVC door bend | BI01010001010000000000000515BI0100001369 | 24 | Each |
| 286 | 286 | 110mm U-PVC plain bend | BI01010001010000000000000515BI0100001370 | 36 | Each |
| 287 | 287 | 110mm U-PVC Plain tee | BI01010001010000000000000515BI0100001371 | 12 | Each |
| 288 | 288 | 110mm dia U-PVC 'P' trap | BI01010001010000000000000515BI0100001372 | 4 | Each |
| 289 | 289 | 110mm dia U-PVC Plain Shoe Bend | BI01010001010000000000000515BI0100001373 | 20 | Each |
| 290 | 290 | 110mm dia U-PVC offset with out ear | BI01010001010000000000000515BI0100001374 | 20 | Each |
| 291 | 291 | 110mm dia U-PVC cowl | BI01010001010000000000000515BI0100001375 | 12 | Each |
| 292 | 292 | 125mm dia CP grating | BI01010001010000000000000515BI0100001376 | 40 | Each |
| 293 | 293 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall | BI01010001010000000000000515BI0100001377 | 50 | Each |
| 294 | 294 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001378 | 16 | Each |
| 295 | 295 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge 580mm size Orissa pan (Parryware / Nycer make ) | BI01010001010000000000000515BI0100001379 | 9 | Each |
| 296 | 296 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware / Nycer make ) | BI01010001010000000000000515BI0100001380 | 9 | Each |
| 297 | 297 | One piece closet (Hindware) No.92084 | BI01010001010000000000000515BI0100001381 | 1 | Each |
| 298 | 298 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Parryware / Hindware make ) | BI01010001010000000000000515BI0100001382 | 3 | Each |
| 299 | 299 | 15mm dia urinal spreader | BI01010001010000000000000515BI0100001383 | 3 | Each |
| 300 | 300 | 32mm dia C.P. dome waste | BI01010001010000000000000515BI0100001384 | 3 | Each |
| 301 | 301 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx400mm size wash hand basin with porcelain pedestal Parryware/ Hind ware /Neyser make ) | BI01010001010000000000000515BI0100001385 | 4 | Each |
| 302 | 302 | (a)W.H.Basin(Under counter-Oval shape)-Jaquar make-Cat. No-CNS-WHT-705(Excluding pillar cock) | BI01010001010000000000000515BI0100001386 | 10 | Each |
| 303 | 303 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thickon 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge . 600mmx450mm size B.E mirror x minimum 5mm thick(Alpina make ) | BI01010001010000000000000515BI0100001387 | 4 | Each |
| 304 | 304 | Big Size Mirror | BI01010001010000000000000515BI0100001388 | 5.94 | Sqm |
| 305 | 305 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge Acrylic glass shelf with CP guard rails | BI01010001010000000000000515BI0100001389 | 4 | Each |
| 306 | 306 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail | BI01010001010000000000000515BI0100001390 | 19 | Each |
| 307 | 307 | C.P. Ring Towel Rail | BI01010001010000000000000515BI0100001391 | 19 | Each |
| 308 | 308 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder | BI01010001010000000000000515BI0100001392 | 19 | Each |
| 309 | 309 | Supplying all materials labour T&P and filling in foundation and plinth with sandwell watered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction of Engineer in charge In ground floor | BI01010001010000000000000515BI0100001393 | 2.43 | Cum |
| 310 | 310 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor | BI01010001010000000000000515BI0100001394 | 0.54 | Cum |
| 311 | 311 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor | BI01010001010000000000000515BI0100001395 | 0.27 | Cum |
| 312 | 312 | In Ist floor | BI01010001010000000000000515BI0100001396 | 0.9 | Cum |
| 313 | 313 | In 2 nd floor | BI01010001010000000000000515BI0100001397 | 2.31 | Cum |
| 314 | 314 | In 3rd floor | BI01010001010000000000000515BI0100001398 | 3.01 | Cum |
| 315 | 315 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor | BI01010001010000000000000515BI0100001399 | 32.46 | Sqm |
| 316 | 316 | In Ist floor | BI01010001010000000000000515BI0100001400 | 53.91 | Sqm |
| 317 | 317 | In 2nd floor | BI01010001010000000000000515BI0100001401 | 181.9 | Sqm |
| 318 | 318 | In 3rd floor | BI01010001010000000000000515BI0100001402 | 256.52 | Sqm |
| 319 | 319 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning for skirting including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ist floor | BI01010001010000000000000515BI0100001403 | 20.6 | Sqm |
| 320 | 320 | In 2 nd floor | BI01010001010000000000000515BI0100001404 | 54.87 | Sqm |
| 321 | 321 | In 3rd floor | BI01010001010000000000000515BI0100001405 | 72.39 | Sqm |
| 322 | 322 | Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001406 | 1.8 | Cum |
| 323 | 323 | In 2nd floor | BI01010001010000000000000515BI0100001407 | 4.62 | Cum |
| 324 | 324 | In 3rd floor | BI01010001010000000000000515BI0100001408 | 6.02 | Cum |
| 325 | 325 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001409 | 20.6 | Sqm |
| 326 | 326 | In 2nd floor | BI01010001010000000000000515BI0100001410 | 54.87 | Sqm |
| 327 | 327 | In 3rd floor | BI01010001010000000000000515BI0100001411 | 72.39 | Sqm |
| 328 | 328 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In first floor | BI01010001010000000000000515BI0100001412 | 0.14 | Cum |
| 329 | 329 | In 2nd floor | BI01010001010000000000000515BI0100001413 | 0.22 | Cum |
| 330 | 330 | In 3rd floor | BI01010001010000000000000515BI0100001414 | 0.26 | Cum |
| 331 | 331 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height | BI01010001010000000000000515BI0100001415 | 0.96 | Sqm |
| 332 | 332 | In 2nd floor | BI01010001010000000000000515BI0100001416 | 1.38 | Sqm |
| 333 | 333 | In 3rd floor | BI01010001010000000000000515BI0100001417 | 1.26 | Sqm |
| 334 | 334 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001418 | 0.08 | Qtl |
| 335 | 335 | In 2nd floor | BI01010001010000000000000515BI0100001419 | 0.11 | Qtl |
| 336 | 336 | In 3rd floor | BI01010001010000000000000515BI0100001420 | 0.1 | Qtl |
| 337 | 337 | Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001421 | 0.1 | Cum |
| 338 | 338 | In 2nd floor | BI01010001010000000000000515BI0100001422 | 0.14 | Cum |
| 339 | 339 | In 3rd floor | BI01010001010000000000000515BI0100001423 | 0.13 | Cum |
| 340 | 340 | Supplying all materials, labour, T&P and providing fixing vetrified tiles with matt finish Kajaria (FOG PERLA ) in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles of 60cm x 60cm including cost conveyance , royalty and taxes etc. all complete as per direction of Engineer - In - Charge | BI01010001010000000000000515BI0100001424 | 6.08 | Sqm |
| 341 | 341 | In Ist floor | BI01010001010000000000000515BI0100001425 | 18.71 | Sqm |
| 342 | 342 | In 2nd floor | BI01010001010000000000000515BI0100001426 | 48.67 | Sqm |
| 343 | 343 | In 3rd floor | BI01010001010000000000000515BI0100001427 | 60.17 | Sqm |
| 344 | 344 | Supplying all materials, labour, T&P and fixing Vetrified tiles of Kajaria (Duren Marfil )to dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles of size 30cm x 60 cm including cost conveyance , royalty and taxes etc. all complete as per direction of Engineer - In - Charge | BI01010001010000000000000515BI0100001428 | 32.46 | Sqm |
| 345 | 345 | In Ist floor | BI01010001010000000000000515BI0100001429 | 53.91 | Sqm |
| 346 | 346 | In 2 nd floor | BI01010001010000000000000515BI0100001430 | 181.9 | Sqm |
| 347 | 347 | In 3rd floor | BI01010001010000000000000515BI0100001431 | 256.52 | Sqm |
| 348 | 348 | Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge | BI01010001010000000000000515BI0100001432 | 1.28 | Sqm |
| 349 | 349 | In 2nd floor | BI01010001010000000000000515BI0100001433 | 2.2 | Sqm |
| 350 | 350 | In 3rd floor | BI01010001010000000000000515BI0100001434 | 1.68 | Sqm |
| 351 | 351 | Supplying all materials, labour, T&P and providing Granite slab urinal partition wall including cutting grooves in wall and making good the damages, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001435 | 0.9 | Sqm |
| 352 | 352 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make) | BI01010001010000000000000515BI0100001436 | 61.43 | Sqm |
| 353 | 353 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 120 PSS RO+UV | BI01010001010000000000000515BI0100001437 | 6 | Each |
| 354 | 354 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia | BI01010001010000000000000515BI0100001438 | 110 | Mtr |
| 355 | 355 | 160mm dia | BI01010001010000000000000515BI0100001439 | 130 | Mtr |
| 356 | 356 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm | BI01010001010000000000000515BI0100001440 | 20 | Each |
| 357 | 357 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm | BI01010001010000000000000515BI0100001441 | 15 | Each |
| 358 | 358 | ---- do --- addl depth of 0.15m upto 0.90m | BI01010001010000000000000515BI0100001442 | 3 | Each |
| 359 | 359 | R.C.P.C.Manhole Cover | BI01010001010000000000000515BI0100001443 | 15 | Each |
| 360 | 360 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm | BI01010001010000000000000515BI0100001444 | 6 | Each |
| 361 | 361 | R.C.P.C.Manhole Cover | BI01010001010000000000000515BI0100001445 | 6 | Each |
| 362 | 362 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.40m dia x 2.00m deep soakway pit | BI01010001010000000000000515BI0100001446 | 2 | Each |
| 363 | 363 | Construction of 100 users RCC Septic tank(2nos) Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. | BI01010001010000000000000515BI0100001447 | 92.4 | Cum |
| 364 | 364 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. | BI01010001010000000000000515BI0100001448 | 55.44 | Cum |
| 365 | 365 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor | BI01010001010000000000000515BI0100001449 | 8.16 | Cum |
| 366 | 366 | Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001450 | 123 | Sqm |
| 367 | 367 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height | BI01010001010000000000000515BI0100001451 | 55.12 | Sqm |
| 368 | 368 | RCC beam,Column, girders and bressmer etc | BI01010001010000000000000515BI0100001452 | 214.08 | Sqm |
| 369 | 369 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor | BI01010001010000000000000515BI0100001453 | 36.35 | Qntl |
| 370 | 370 | Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor | BI01010001010000000000000515BI0100001454 | 48.47 | Cum |
| 371 | 371 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside/outside) | BI01010001010000000000000515BI0100001455 | 167.68 | Sqm |
| 372 | 372 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside) | BI01010001010000000000000515BI0100001456 | 133.92 | Sqm |
| 373 | 373 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001457 | 12 | Each |
| 374 | 374 | Supplying all materials, labour, T&P and providing brick work with fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In foundation and plinth | BI01010001010000000000000515BI0100001458 | 1.7 | Cum |
| 375 | 375 | Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001459 | 2 | Each |
| 376 | 376 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm diameter U-PVC SWR pipe | BI01010001010000000000000515BI0100001460 | 3.6 | Mtr |
| 377 | 377 | 110mm dia U-PVC Plain shoe bend | BI01010001010000000000000515BI0100001461 | 2 | Each |
| 378 | 378 | 110mm dia U-PVC Cowl | BI01010001010000000000000515BI0100001462 | 2 | Each |
| 379 | 379 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 2 x2 x(8.80+2.90) x 0.30 x 2.40 | BI01010001010000000000000515BI0100001463 | 33.7 | Cum |
| 380 | 380 | Construction of 100000 Liters RCC Under ground Reserver of Inside size- 10.00x5.50x2.10m-Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. | BI01010001010000000000000515BI0100001464 | 126.36 | Cum |
| 381 | 381 | -do- with Ist additional depth of 1.50 m over the initial lead and lift | BI01010001010000000000000515BI0100001465 | 101.09 | Cum |
| 382 | 382 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. | BI01010001010000000000000515BI0100001466 | 25.27 | Cum |
| 383 | 383 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001467 | 13.95 | Cum |
| 384 | 384 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001468 | 53.92 | Cum |
| 385 | 385 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. | BI01010001010000000000000515BI0100001469 | 53.92 | Qtl |
| 386 | 386 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC floor roof, chajja etc | BI01010001010000000000000515BI0100001470 | 61.6 | sqm |
| 387 | 387 | RCC Beam, Column, wall etc | BI01010001010000000000000515BI0100001471 | 165.75 | sqm |
| 388 | 388 | RCC Plinth bend/ Raft | BI01010001010000000000000515BI0100001472 | 27.68 | sqm |
| 389 | 389 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. | BI01010001010000000000000515BI0100001473 | 139.9 | sqm |
| 390 | 390 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. | BI01010001010000000000000515BI0100001474 | 139.9 | sqm |
| 391 | 391 | Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete | BI01010001010000000000000515BI0100001475 | 120 | Kg |
| 392 | 392 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge | BI01010001010000000000000515BI0100001476 | 2 | each |
| 393 | 393 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. | BI01010001010000000000000515BI0100001477 | 69.3 | sqm |
| 394 | 394 | De-watering | BI01010001010000000000000515BI0100001478 | 100 | hphr |
| 395 | 395 | Sinking of 150mm dia tubewell through hand boring (water jet ) method (2nos) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge | BI01010001010000000000000515BI0100001479 | 2 | Each |
| 396 | 396 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge | BI01010001010000000000000515BI0100001480 | 2 | Each |
| 397 | 397 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres | BI01010001010000000000000515BI0100001481 | 240 | Mtr |
| 398 | 398 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres | BI01010001010000000000000515BI0100001482 | 240 | mtr |
| 399 | 399 | Reaming 150mm to 200mm dia from 0 to 360 metres | BI01010001010000000000000515BI0100001483 | 240 | mtr |
| 400 | 400 | Reaming 200 mm to 250mm dia from 0 to 360 metres | BI01010001010000000000000515BI0100001484 | 240 | mtr |
| 401 | 401 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres | BI01010001010000000000000515BI0100001485 | 2 | mtr |
| 402 | 402 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. | BI01010001010000000000000515BI0100001486 | 2 | Each |
| 403 | 403 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres | BI01010001010000000000000515BI0100001487 | 240 | Mtr |
| 404 | 404 | Cost of 150mm dia PVC ASTM pipe (sch-80) | BI01010001010000000000000515BI0100001488 | 241 | Mtr |
| 405 | 405 | Cost of 150mm dia PVC cutting slut | BI01010001010000000000000515BI0100001489 | 20 | Mtr |
| 406 | 406 | Cost of 150 mm dia C.I. cutter plug | BI01010001010000000000000515BI0100001490 | 2 | Nos |
| 407 | 407 | Cost of bentonite powder | BI01010001010000000000000515BI0100001491 | 40 | Qtl |
| 408 | 408 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge | BI01010001010000000000000515BI0100001492 | 5 | cum |
| 409 | 409 | Cost and Conveyance of Gravel | BI01010001010000000000000515BI0100001493 | 5 | Cum |
| 410 | 410 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge | BI01010001010000000000000515BI0100001494 | 5 | cum |
| 411 | 411 | Cost and Conveyance of sand | BI01010001010000000000000515BI0100001495 | 5 | cum |
| 412 | 412 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. | BI01010001010000000000000515BI0100001496 | 2 | Each |
| 413 | 413 | Cost of Cement | BI01010001010000000000000515BI0100001497 | 4 | Qtls |
| 414 | 414 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor | BI01010001010000000000000515BI0100001498 | 2 | Each |
| 415 | 415 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm | BI01010001010000000000000515BI0100001499 | 2 | Each |
| 416 | 416 | DOL Control panel | BI01010001010000000000000515BI0100001500 | 2 | Each |
| 417 | 417 | 40mm dia steel short piece | BI01010001010000000000000515BI0100001501 | 4 | Each |
| 418 | 418 | Well cap | BI01010001010000000000000515BI0100001502 | 4 | Each |
| 419 | 419 | 50mm size CI bracket | BI01010001010000000000000515BI0100001503 | 4 | Each |
| 420 | 420 | 2.50sqmm flat cable | BI01010001010000000000000515BI0100001504 | 180 | Mtr |
| 421 | 421 | 20mm dia rigid UPVC pipes | BI01010001010000000000000515BI0100001505 | 190 | Mtr |
| 422 | 422 | Steel rope with cover | BI01010001010000000000000515BI0100001506 | 70 | Mtr |
| 423 | 423 | 32mm dia HDPE pipe | BI01010001010000000000000515BI0100001507 | 60 | Mtr |
| 424 | 424 | Labour charges for lowering including transportation | BI01010001010000000000000515BI0100001508 | 2 | Each |
| 425 | 425 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001509 | 2 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail