| 1 | 1 | Dismantling old plaster or, skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | | 67.21 | sqm |
|---|
| 2 | 2 | Brick work with well burnt chimney bricks in bulls patent trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plith level and up to floor two level i/c curing etc complete.Cement mortar 1:4 (1 cement : 4 sand) | | 3.52 | cum |
|---|
| 3 | 3 | Brick work with well burnt chimney bricks in bulls patent trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement mortar 1:4 (1 cement : 4 sand) | | 3.03 | cum |
|---|
| 4 | 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : With 20mm nominal size graded stone aggregate.\nM 15 – Grade concrete | | 1.26 | cum |
|---|
| 5 | 5 | Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls,return walls,walls (any thickness) including attached pilasters,\nbuttresses, plinth and string courses fillets etc. | | 1.14 | sqm |
|---|
| 6 | 6 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement : 3 sand) | | 127.02 | sqm |
|---|
| 7 | 7 | Providing and layin water proofing treatment on roofs of slabs by appliyng cement slurry mixed with water proofing cement compound consisting of applying : \na) After surface Preparation, first layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm \nb) laying second layer of fiber glass cloth when the first layer is still green. Overlaps of joints of fiber cloth should not be less then 10cm.\nc) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg /sqm mixed with water proofing cement compound @ of 0.670kg/sqm and sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hour followed by water curing for 48/ hour. The entire treatment will be taken upto 30cm on parapet wall and trucked into groove in parapet all around. | | 407.88 | sqm |
|---|
| 8 | 8 | Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand)prepared same day whem mortar is still green i.e. within 6hrs. including grouting the joints with white cement and matching pigments etc., complete. | | 53.76 | sqm |
|---|
| 9 | 9 | Providing and fixing 10mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding and joints fild with acid and / or alkali resisting cement as per is :4457 complete as per the direction of engineer-in-Charge.\n\nIn flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement : 4 sand)\n\nAcid and alkal;i resistant tiles | | 9.6 | sqm |
|---|
| 10 | 10 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :\n\nW.C. pan with ISI marked white solid plastic seat and lid | | 4 | each |
|---|
| 11 | 11 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required :\n\nSingle half stall urinal with 5 litre P.V.C. automatic flushing cistern.\n\n | | 4 | each |
|---|
| 12 | 12 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :\n\nWhite Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. | | 4 | each |
|---|
| 13 | 13 | Providing and fixing white vitreous china laboratry sink with C.I. brackets , C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required: \n\nSize 600*450*200mm | | 1 | each |
|---|
| 14 | 14 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :\n\nWater thinnable cement primer. | | 3745.81 | sqm |
|---|
| 15 | 15 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :\n\nOne or more coats on old work. | | 2351.57 | sqm |
|---|
| 16 | 16 | Finishing walls with Acrylic Smooth exterior paint of required shade :\n\nOld work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).\n | | 1394.24 | sqm |
|---|
| 17 | 17 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of such as duro board, century or equivelant make.\n\n35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. | | 14.91 | sqm |
|---|
| 18 | 18 | Painting with oil type wood presarvative of approved brand and manufacture. \n\nOld work (one or more coats) | | 113.22 | sqm |
|---|
| 19 | 19 | Finishing walls with Deluxe multi surface paint system for interiors and exteriors using primer as per manufactures specifications. \n\nPainting wood work with deluxe muli surface paint of requried shade. one or more coat applied @ 0.70 ltr./10sqm | | 143.04 | sqm |
|---|
| 20 | 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :\n\nOne or more coats on old work. | | 256.74 | sqm |
|---|
| 21 | 21 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:\nFloat glass panes of thickness 4 mm | | 47.42 | sqm |
|---|
| 22 | 22 | Renewal of old putty of glass panes (length) | | 563 | meter |
|---|
| 23 | 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\n\nInternal work - Exposed on wall\n20 mm nominal outer dia .Pipes. | | 60 | meter |
|---|
| 24 | 23.1 | 32 mm nominal outer dia .Pipes. | | 40 | meter |
|---|
| 25 | 24 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :\n\n32 mm nominal bore. | | 3 | each |
|---|
| 26 | 25 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | | 1000 | per litter |
|---|
| 27 | 26 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931\n\n15 mm nominal bore. | | 8 | each |
|---|
| 28 | 27 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.\n15 mm nominal bore | | 6 | each |
|---|
| 29 | 28 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931\n15 mm nominal bore | | 4 | each |
|---|
| 30 | 29 | Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour.\n\n15 mm nominal bore with 45 cm length. | | 4 | each |
|---|
| 31 | 30 | Providing and fixing CP jet assembly to including connection etc complete. | | 4 | each |
|---|
| 32 | 31 | Providing and laying vitrified tiles in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer in all colours and shade , laid with cement based high polymer modified quick set tile adhesive ( water based ) conforming to IS:15477, in averege 6mm thickness, including grouting of joints ( payment for grouting of joints to be made sprately) \n \n-size of tile 600*600*9-10mm | | 80.36 | sqm |
|---|
| 33 | 32 | Providing and laying vitrified tiles in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer in all colours and shade , in skirting, riser of staps laid with cement based high polymer modified quick set tile adhesive ( water based ) conforming to IS:15477, in averege 6mm thickness, including grouting of joints ( payment for grouting of joints to be made sprately) \n size of tile 600*600*9-10 mm | | 5.24 | sqm |
|---|
| 34 | 33 | Grouting the joints of flooring /skirting, risers of step of vitrified tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge.\nSize of Tile 600x600 mm | | 85.6 | sqm |
|---|
| 35 | 34 | Provinding and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, like birla white/J.K. white or equivalent over the plastered wall surface to preparing the surface even and smooth i/c all cost of material labor and scaffold etc. in all postion complete. | | 25 | sqm |
|---|
| 36 | 35 | Providing and fixing fly proof galvanized M.S. wire to windows and clewestory windows using wire gauge with average width of aperture 1.4 mm in both direction with wire of dia. 0.63 mm all complete. \n\nWith 2nd class teak wood beading 62*19 mm. | | 35.2 | sqm |
|---|
| 37 | 36.1 | Providing and fixing unplasticised rigid PVC soil and waste pipes conforming to IS : 13592 type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 Kg/sqcm.\n\n75 mm diameter ( minimum wall thickness 3.2 mm ) | | 12 | m |
|---|
| 38 | 36.2 | Providing and fixing unplasticised rigid PVC soil and waste pipes conforming to IS : 13592 type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 Kg/sqcm.\n\n110 mm diameter ( minimum wall thickness 3.2 mm ) | | 16 | m |
|---|
| 39 | 37.1 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticiesd rigid PVC soil and waste pipes conforming to IS : 13592 type A incliding jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. \n\nCoupler 75 mm | Bend 87.50 | 2 | each |
|---|
| 40 | 37.2 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticiesd rigid PVC soil and waste pipes conforming to IS : 13592 type A incliding jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. \n\n110 mm | | 2 | each |
|---|
| 41 | 38.1 | Single tee without door 75*75*75 mm | | 4 | each |
|---|
| 42 | 38.2 | Single tee without door 110*110*110 mm | | 4 | each |
|---|
| 43 | 39.1 | Bend 87.50 \n75 mm bend \n\n | | 15 | each |
|---|
| 44 | 39.2 | Bend 87.50\n110 mm bend | | 8 | each |
|---|
| 45 | 40 | Providing and fixing P.V.C. waste pipe for sink or wash basin incliding P.V.C. waste fitting complete. \nSemi rigid pipe \n40 mm Dia | | 12 | each |
|---|
| 46 | 41 | Providing and fixing uPVC trap of self cleaning design complet. Including cost of cutting and making good the wall and floors.\n\n100 mm inlet and 75 mm outlet | | 6 | each |
|---|
| 47 | 42 | providing and fixing stainless steel ( Grade 304) railing made of hollow tubes, channels, plates etc. including weding, grinding, buffing, polishing and making curvature ( wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bokts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoris such as nuts, bolts, fastenrs etc. ) | | 25 | kg |
|---|
| 48 | 43 | Centering and shuttering including strutting, propping etc. and removal of form for :\n\nShelves (Cast in situ) | | 45.9 | sqm |
|---|
| 49 | 44 | Reinforcement for R.C.C. work including straightening. Cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete. \n\nMild steel and medium tensile steel bars. | | 180.45 | kg |
|---|
| 50 | 45 | Reinforced cement concrete work (with 20 mm nomnial size graded stone aggregate) in beams. Supended floors. Roofs having slope of any degree landings. Balconies, shelves. Chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level and up to floor tow level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. | | 2.51 | cum. |
|---|
| 51 | 46 | GSTIN 12% | | 1 | Rupees |
|---|