| 1 | 1 | M & L in repair for Sub main wiring with single core 2.5 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade drawn through steel conduit/ existing concealed /open PVC conduit / PVC Casing - caping, ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 1.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board to light / fan / any description and testing on completion etc incl re-fixing the conduit/ PVC casing caping, other accessories for the following runs all as specified and directed by Engineer-in-charge. | | 150 | RM |
|---|
| 2 | 2 | All as per item No 1.00 here in before but of 2 runs (2.5 Sqmm) | | 200 | RM |
|---|
| 3 | 3 | S & F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and directed by Engineer-in-Charge. \n | | 15 | Each |
|---|
| 4 | 4 | S & F in repairs 1x60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified and directed by Engineer-in-Charge. | | 30 | Each |
|---|
| 5 | 5 | M & L for in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc all as specified and directed by Engineer-in-Charge. | | 30 | Each |
|---|
| 6 | 6 | Supply and fix in repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole/high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. | | 18 | Each |
|---|
| 7 | 7 | Supply and fix in repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole/high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed by Engineer-in-Charge. | | 15 | Each |
|---|
| 8 | 8 | S & F in repairs wind LED wellglass luminaires 1 x 30 watts Energy saving, environment friendly & robust open type vertical LED luminaire with high power LED as light source all as specified and as directed. | | 12 | Each |
|---|
| 9 | 9 | Fixing only LED High bay luminaires of any make any type of capacity 80 W to 140 W in hangar upto height of 18 mtr including making necessary electric connection and removal of old unserviceable lights and depositing to MES yard comlete all as specified and directed by Engr-in-Charge. Note :- (a) Highbay lights will be supplied under Sch B items. | | 60 | Each |
|---|
| 10 | 10 | S & F in repairs LED High bay luminaires 1x195 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge. | | 14 | Each |
|---|
| 11 | 11 | S & F in repairs LED High bay luminaires 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge. | | 16 | Each |
|---|
| 12 | 12 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core type complete including conduits/casing caping etc, removing the materials/ debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish all as specified and directed by Engineer-in-Charge. | | 600 | RM |
|---|
| 13 | 13 | M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc all as specified and directed by Engr-in-charge.\n(Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) | | 150 | RM |
|---|
| 14 | 14 | All as per item No 13.00 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor. | | 200 | RM |
|---|
| 15 | 15 | All as per item No 13.00 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor. | | 50 | RM |
|---|
| 16 | 16 | All as per item No 13.00 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor. | | 60 | RM |
|---|
| 17 | 17 | All as per item No 13.00 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor. | | 60 | RM |
|---|
| 18 | 18 | All as per item No 13.00 here in before, but four run of single core 16 sqmm and two runs of 10 sqmm cables as earth continuity conductor. | | 80 | RM |
|---|
| 19 | 19 | S & F in repairs Switch Flameproof WP Rotary type with termination box in LM6,15A single pole 250V all as specified and directed by Engineer-in-Charge. | | 12 | Each |
|---|
| 20 | 20 | Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and directed by Engineer-in-Charge. | | 29 | Each |
|---|
| 21 | 21 | S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified. | | 14 | Each |
|---|
| 22 | 22 | All as per item No 21 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar triple pole. | | 4 | Each |
|---|
| 23 | 23 | S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and directed by Engr-in-charge. | | 4 | Each |
|---|
| 24 | 24 | All as per item No 23 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated busbar. | | 2 | Each |
|---|
| 25 | 25 | All as per item No 23 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar. | | 2 | Each |
|---|
| 26 | 26 | S&F in repairs MCB DB TPN, 8 way, (MCCB + 24 way O/G) double door, vertical type provision one MCCB of 100 amps breaking capacity 18 KA, 4 pole without MCB complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 27 | 27 | S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 28 | 28 | S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 15 | Each |
|---|
| 29 | 29 | S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 12 | Each |
|---|
| 30 | 30 | S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 10 | Each |
|---|
| 31 | 31 | S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 8 | Each |
|---|
| 32 | 32 | S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 25 | Each |
|---|
| 33 | 33 | S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge. | | 100 | Each |
|---|
| 34 | 34 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. \n | | 4 | Each |
|---|
| 35 | 35 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engr-in-charge. \n | | 3 | Each |
|---|
| 36 | 36 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engineer-in-Charge. \n | | 4 | Each |
|---|
| 37 | 37 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-charge. \n | | 2 | Each |
|---|
| 38 | 38 | Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's c complete all as specified and directed by Engr-in-charge. | | 3 | Each |
|---|
| 39 | 39 | Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's c complete all as specified and directed by Engineer-in-Charge. \n | | 2 | Each |
|---|
| 40 | 40 | Fixing only Energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lights and depositing to MES yard comlete all as specified and directed by Engr-in-Charge.\nNote :- (a) LED tube lights fittings will be supplied under Sch B items. | | 300 | Each |
|---|
| 41 | 41 | Fixing only recess mounting high lumen LED flat panel 2' x 2' 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable ans depositing to MES yard comlete all as specified and directed by Engineer-in-Charge.\nNote :- (a) LED tube lights fittings will be supplied under Sch B items. | | 80 | Each |
|---|
| 42 | 42 | Fixing only Energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr etc.and necessary fixing arrangement at any height and removing old unserviceable ans depositing to MES yard comlete all as specified and directed by Engineer-in-Charge.\nNote :- (a) LED tube lights fittings will be supplied under Sch B items. | | 30 | Each |
|---|
| 43 | 43 | Supply & fix recess mounting high lumen LED flat panel 1'x1' 18 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed by Engineer-in-Charge. | | 26 | Each |
|---|
| 44 | 44 | Supply & fix recess mounting high lumen LED flat panel 4' x 1' 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed by Engineer-in-Charge. | | 25 | Each |
|---|
| 45 | 45 | S&F in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic driver complete all as specified and directed by Engineer-in-charge.\n | | 30 | Each |
|---|
| 46 | 46 | S & F in repairs Fluorescent tube light fitting. 1x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-charge. | | 12 | Each |
|---|
| 47 | 47 | S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc complete all as specified and as directed. | | 200 | RM |
|---|
| 48 | 48 | S & F in repairs knob suitable for Rotary type Flamproof switch in LM6, 15A single pole 250V complete all as specified and as directed. | | 10 | Each |
|---|
| 49 | 49 | Supply and fix down rod made of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer. | | 40 | Each |
|---|
| 50 | 50 | M & L for Earthing complete with GI earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engineer-in-Charge including demolish existing earth pit taking out old materials complete all as specified and directed by Engineer-in-Charge. | | 5 | Each\n |
|---|
| 51 | 51 | M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR Part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 52 | 52 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. | | 2 | Each\n |
|---|
| 53 | 53 | S & F copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-Charge. | | 20 | RM |
|---|
| 54 | 54 | S & F in repairs Detectors Complying with and type certified to EN - 45 Addressable type Multi sencor with heat and smoke combination Photoelectric/Optical with base with self built intelligence as per IS: 11360 all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 55 | 55 | All as per item No 54.00 but of addressable type smoke detector Photoelectric/Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 56 | 56 | S & F in repairs ABC type fire extinguisher with delivery hose, mounting clamps, and standard accessories of capacity 9 kg capacity all as specified and directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 57 | 57 | All as per item No 56.00 here in before but of capacity 6.0 kg capacity. | | 6 | Each |
|---|
| 58 | 58 | Dismantling the existing electric chimney system of 5 HP blower motor capacity complete by disconnecting all incoming and outgoing elect connections carefully along with blower motor, hood, hood cover, ducts, etc. removing the carbon/dust/oil layer from the inside wall of complete inlet/outlet ducting and hood system thoroughly by using kerosene/high pressure water jet wash/suitable solvent and re-assembling the same after completion of repair/cleaning work incl the following works complete all as specified and directed by Engineer-in-Charge.\n(a) Alignment of whole system inlet and outlet blower assy with motor for smooth functioning incl greasing of blower and motor bearings.\n(b) Replacement of GI Sheet for 5 HP blower motor cover - 01 No\n(c) Replacement of new rubber gasket for GI inlet/outlet duct flanges with new GI nut bolt and washers of suitable size.\n | | 2 | Each Job |
|---|
| 59 | 58.01 | (d) Arrest the vibration of ducts by using suitable arrangements such as angle iron support, rubber pads, anchor bolts complete upto recommended level.\n(e) Painting of GI inlet/outlet ducts along with MS flanges and nut, bolts in the outer side by means of synthetic enamel paint two coat over a coat of red oxide primer. and paid separately under relevant item of this schedule)\n(f) Fabrication and fixing of strainer made out of MS wire 3 mm thick having 20 mm width of duct outlet opening size. | | | |
|---|
| 60 | 58.02 | (g) Connecting of elect cables to blower motor/suction motor\n(h) Cleaning of inlet and blower fan and painting with one coat of synthetic enamel paint by using spray gun.\n(j) Repairing the blower fins by denting , painting and trimming and making good.\n(k) Applying one coat synthetic enamel paint to Blower motor, suction fan with blade by spray after cleaning the outer surface area complete. \n(l) Other minor works such as grouting, supporting clamps, nut bolt and washers incl replacement of tarpaulin cloth of existing size to make the plants smooth functioning.. (Location : Hansa Vihar Galley, DSC mess, main galley, BSF galley and PO's galle)\n(Note : New spares like GI ducting, MS angle iron works, cables, motor winding and starter will be measured and paid separately under relevant item of this schedule) | | | |
|---|
| 61 | 59 | All as per item No 58.00 here in before but of Blower fan capacity 10 HP. (Loc : Ward Room area) | | 1 | Each Job |
|---|
| 62 | 60 | S & F in repairs incl fabrication of Air inlet/outlet duct made up of GI Sheet 1.0 mm thick with connecting/ supporting flange, rubber gasket, fixing clamps, nut, bolt and washers as per existing size and shape complete all as specified and directed by Engineer-in-Charge. | | 12 | Per Sqm |
|---|
| 63 | 61 | S & F in repairs ball bearing for blower shaft - 02 Nos & blower motor - 02 Nos suitable for 5 HP capacity blower motor Chimney all as directed. | | 2 | Set |
|---|
| 64 | 62 | S & F in repairs ball bearing for blower shaft - 02 Nos & blower motor - 02 Nos suitable for 10 HP capacity blower motor Chimney all as directed. | | 1 | Set |
|---|
| 65 | 63 | S & F in repairs canvas cloth suitable for Elect Chimney's Air inlet / outlet GI duct joints / extension incl replacement of old nut, bolt and washers complete all as specified and directed by Engineer-in-Charge. | | 4 | Sqm |
|---|
| 66 | 64 | S & F in repairs Air suction fan with blade 3-5 HP capacity Elect Chimney three phase with blade of existing capacity / rating / model and size and fixed in position complete all as specified and directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 67 | 65 | Disconnecting the motor from the blower assy of any make/model electric driven AC 3 phase, 415 Volts of 5 to 10 HP of any make/model from any Elect Chimney's transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing and re-installation at same position including commissioning and testing complete all as specified and directed by Engineer-in-Charge. (Minor spares such as repair / replacement of terminal box, terminals, fan blade shall be deemed to included in the quoted rates) | | 15 | Per HP |
|---|
| 68 | 66 | Disconnecting the Air suction fan of any make/model electric driven AC three phase, 415 Volts 3-5 HP of any make/model from any Elect Chimney's transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, replacement of fan blade, bearings, bushes complete and re-installation at same position complete all as specified and directed by Engineer-in-Charge. | | 2 | Each\njob |
|---|
| 69 | 67 | S & F in repairs fully automatic Star Delta moter starter ML 1.5 in sheet steel enclosure suitable for 3 phase 440 Volts with relay range 13-21 A incl necessary connections for Electric Chimney blower motor complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 70 | 68 | Supply and wrapping of LT insulation tape 12 mm width in 5 mtr roll complete all as specified and directed by Engineer-in-charge. \n | | 100 | Roll |
|---|
| 71 | 69 | S & F in repairs lead acid battery 12 Volt 90 AH for fire detection system complete all as specified and directed by Engr-in-charge. \n | | 2 | Each |
|---|
| 72 | 70 | S & F in repairs connecting and commissioning sealed maint free battery 12 volts 42 AH. | | 4 | Each |
|---|
| 73 | 71 | S & F in repairs connecting and commissioning sealed maint free battery 12 volts 7 AH. | | 5 | Each |
|---|
| 74 | 72 | Supply only electrical insulation rubber mating ISI marked and size 1m x 2m x 6mm thick complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 75 | 73 | S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge. | | 12 | Each |
|---|
| 76 | 74 | S & F Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified. | | 20 | Sqm |
|---|
| 77 | 75 | M & L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and directed by Engineer-in-Charge. | | 45 | Sqm |
|---|
| 78 | 76 | S & F in repairs capacitor of 2.5/3.15 mfd capacity for ceiling fan of any sweep complete all as specified and directed by Engineer-in-Charge. | | 300 | Each |
|---|
| 79 | 77 | Painting of ceiling fans complete, in situ with one coat of synthetic enamel paint by spray gun after cleaning all dust etc. complete all as specified and directed by Engineer-in-Charge. | | 600 | Each |
|---|
| 80 | 78 | Taking down carefully flameproof ceiling fans of size 1200 mm sweep at any height of any sweep /make / model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts, spring washers for blade / body etc and replacement of components/ accessories such as ball bearings, gun metal bushes, capacitor, canopy top& bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed by Engineer-in-Charge. | | 8 | Job |
|---|
| 81 | 78.01 | Note:- (i) Rewinding of fan motor, painting will be measured and paid separetly under relevant item of schedule. (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate | | | |
|---|
| 82 | 79 | All as per item No. 78.00 above,but flameproof exhaust fan of size upto 300 mm and 380 mm sweep complete all as specified and directed by Engineer-in-Charge. | | 5 | Job |
|---|
| 83 | 80 | Material and labour for rewinding of flameproof ceiling fan motor of size 1200 mm mm sweep of any make / model / type with new supper enamelled copper winding wire of similar gauge and number of turns as existing, including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 84 | 81 | All as per item No 80.00 here in before but of flameproof exhaust fan of size upto 300 mm and 380 mm sweep complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 85 | 82 | S&F in repair informatory sign boards/ display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and directed by Engineer-in-Charge.\nNote :- wright matters will be provided by departmaint as per requirment. | | 15 | Sqm |
|---|
| 86 | 83 | S&F in repair hylem sheet of 03 mm thick fixed on angle Iron/switch boad with screw nuts and bolts etc. complete all as specified and directed by Engineer-in-Charge. | | 10 | Sqm |
|---|
| 87 | 84 | S & F in repairs Surge protection devices type -2, 4 pole in sheet steel enclosure and testing and commissioning with screw. nuts and bolts etc. all as specified and directed by Engineer-in-Charge. \n | | 6 | Each |
|---|
| 88 | 85 | S & F in repairs Air termination, single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engineer-in-Charge. | | 12 | Each |
|---|
| 89 | 86 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8 mm dia 25mm long hex. Head screw complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 90 | 87 | Taking down Aluminum strip of size 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and refixing in the same location with new nuts and bolts, screws of suitable size and length and connected to air termination rod on op of the hangar complete all as specified and directed by Engineer-in-Charge. | | 130 | RM |
|---|
| 91 | 88 | S & F in repairs Copper strip 20x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground incl taking out old one complete all as specified and directed by Engineer-in-Charge. | | 120 | RM |
|---|