| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil. | 2.6.1 | 1.23 | cum |
|---|
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.Ordinary rock | 2.7.1 | 1768.5 | cum |
|---|
| 3 | 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). | 4.1.10 | 25.89 | cum |
|---|
| 4 | 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 5.2.2 | 1.17 | cum |
|---|
| 5 | 5 | Centering and shuttering including strutting, propping etc. and removal of form for:\rColumns, Pillars, Piers, Abutments, Posts and Struts\n | 5.9.6 | 10.44 | sqm |
|---|
| 6 | 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. | 5.22.6 | 150 | Kg |
|---|
| 7 | 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | 6.4.2 | 1.85 | cum |
|---|
| 8 | 8 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Float glass panes 4 mm thick glass pane | 9.7.7.1 | 12.69 | sqm |
|---|
| 9 | 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | 10.25.2 | 345 | kg |
|---|
| 10 | 10 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. | 10.25.3 | 34.35 | cum |
|---|
| 11 | 11 | 20 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | 10.25.4 | 7.67 | sqm |
|---|
| 12 | 12 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 10.25.5 | 7.67 | sqm |
|---|
| 13 | 13 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) | 10.25.6 | 105.66 | sqm |
|---|
| 14 | 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work | 10.25.7 | 186.12 | sqm |
|---|
| 15 | 15 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification.One or more coats on old work | 10.25.8 | 1265.4 | sqm |
|---|
| 16 | 16 | Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface | 10.25.9 | 486.67 | sqm |
|---|
| 17 | 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads\nincluding all lifts involved. | 10.25.10 | 8.61 | cum |
|---|
| 18 | 18 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | 10.25.11 | 343.5 | sqm |
|---|
| 19 | 19 | Providing and fixing soil, waste and vent pipes :100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 | 10.25.12 | 8 | metre |
|---|
| 20 | 20 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work40 mm dia nominal bore | 10.25.13 | 50 | metre |
|---|
| 21 | 21 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter | 10.25.14 | 20 | metre |
|---|
| 22 | 22 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe | 10.25.15 | 20 | metre |
|---|
| 23 | 23 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 10.25.16 | 2 | each |
|---|
| 24 | 24 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 10.25.17 | 8 | each |
|---|
| 25 | 25 | Providing and fixing in position uPVC SWR grade special/ fitting of approved make including souitable jointing to ensure leak service and including cutting holes in wall roff and floors etc and making good to its original condition as per specification and satisfaction of the engineer-in-charge.min. 6kg/cm2 door bend 110 mm | 10.25.18 | 2 | each |
|---|
| 26 | 26 | Providing and fixing in position uPVC SWR grade special/ fitting of approved make including suitable jointing to ensure leak service and including cutting holes in wall roff and floors etc and making good to its original condition as per specification and satisfaction of the engineer-in-charge.min. 6kg/cm2 plain bend 110 mm | 10.25.19 | 2 | each |
|---|
| 27 | 27 | Providing and fixing PVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required (For soil & waste pipes ) Nothing extra will be paid for supports (Inside Toilets & Kitchen) 110 mm min 6kg/cm2 | 10.25.20 | 30 | Rmtr |
|---|
| 28 | 28 | Providing and fixing M.S. grills of required pattern in frames of Door etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. | 10.25.21 | 130 | Kg |
|---|