Special Repair To Bldg No T-565 , Provision Of Corrugated Sheet In Replacement Of Existing Asbestos Sheet And Provn Of Solar Water Heating System In Certain Bldgs Under Ge ( Fw ) Kolkata, Fort William Kolkata-West Bengal

Military Engineer Services-MES has published Special Repair To Bldg No T-565 , Provision Of Corrugated Sheet In Replacement Of Existing Asbestos Sheet And Provn Of Solar Water Heating System In Certain Bldgs Under Ge ( Fw ) Kolkata. Submission Date for this Tender is 25-03-2021. Building Repair Tenders in Fort William Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27217115
Special Repair To Bldg No T-565 , Provision Of Corrugated Sheet In Replacement Of Existing Asbestos Sheet And Provn Of Solar Water Heating System In Certain Bldgs Under Ge ( Fw ) Kolkata
Open Tender
Indian
West Bengal
Fort William Kolkata
25-03-2021

Tender Details

Special Repair To Bldg No T-565 , Provision Of Corrugated Sheet In Replacement Of Existing Asbestos Sheet And Provn Of Solar Water Heating System In Certain Bldgs Under Ge ( Fw ) Kolkata

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR TO BLDG NO T-565, PROVN OF CORRUGATED SHEET IN REPLACEMENT OF EXISTING ASBESTOS SHEET AND PROVN OF SOLAR WATER HEATING SYSTEM IN CERTAIN BLDGS UNDER GE (FW) KOLKATA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I (B/R WORKS)
2 1.01 Dismantling of wall and ceiling board, of any thickness including cover fillets complete all as specified and directed. 95 SQM
3 1.02 S&F 6 mm thick asbestos cement plain building boards, fixed to timber/steel framework in ceiling with screws complete all as specified and directed. 95 SQM
4 1.03 M&L for asbestos cement building board cover strips, 50 mm X 5 mm, with bevelled edges over joints including all mitres etc, fixed with screws complete all as specified and directed. 400 RM
5 1.04 Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed. 300 Sqm
6 1.05 Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed. 170 Sqm
7 1.06 Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as a specified and as directed 1672 Sqm
8 1.07 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 7 QUINTAL
9 1.08 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, steel window or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed. 8 Sqm
10 1.09 Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. 3 Cum
11 1.1 M&L joint free non skid ceramic 7 to 8 mm thick coloured tiles, joint free, (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment as in floor, laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. 150 Sqm
12 1.11 -ditto- but as in skirting, fixed over 10mm thick screed bed in cement mortar 1:4. 10 Sqm
13 1.12 M&L glazed coloured ceramic tiles in vertical surface 300 X 450 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed. 10 SQM
14 1.13 S&F 4 mm thick sheet glass, ordinary quality, in squares not exceeding 0.5 sqm in each pane complete all as specified and directed. 8 SQM
15 1.14 S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 12 SQM
16 1.15 -ditto- but including taking down of existing wire cloth 10 SQM
17 1.16 M&L for pre-polished Chequered cement concrete tiles (coloured) of size 400 mm X 400 mm X 25mm thick , set, jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed . 140 SQM
18 1.17 M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed. 150 SQM
19 1.18 M&L for preparation of surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on new plastered surfaces complete all as specified and directed. 250 SQM
20 1.19 M&L for preparation of old decorated surfaces and applying one coat of cement base paint complete all as specified and directed. 600 SQM
21 1.2 M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new untreated steel surfaces exc 10 cm width or girth including preparation of surfaces complete all as specified and as directed. 45 SQM
22 1.21 M & L for applying one coat of synthetic enamel paint ed oxide primer on old decorated steel surfaces exc 10 cm width or girth including preparation of surfaces complete all as specified and as directed. 70 SQM
23 1.22 M&L for preparation of new untreated wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 50 SQM
24 1.23 M&L for preparation of old decorated wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 100 SQM
25 1.24 M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed. 0.01 PER 100 NOS
26 1.25 -ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each 0.01 PER 100 NOS
27 1.26 S&F Bands, straps, supports or stays for rainwater, ventilating, pipes, including bolts, if required hooks(stays ) heavy for large gates hook and pintle hinges large hasps and staples, chains hand made sliding bolts, clamps, hold fasts, plain angle cleats for securing purlins to wood trusses or rafters knee piece inserts two way and three way straps plate washers and similar small articles conforming to fe-290 Gde E-165 complete all as specified and directed. 2 Kg
28 1.27 Materials and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cills, copings, kneelers, apex stones, bed plates etc incl formwork complete all as specified and as directed. 1.02 CUM
29 1.28 Supply & fixing 100mm mild steel butt hinges (medium weight) cold rolled complete all as specified and directed. 12 Each
30 1.29 Supply & fixing 75 mm mild steel butt hinges (medium weight) cold rolled complete all as specified and directed. 12 Each
31 1.3 Supply & fixing 150 mm size aluminium anodised barrel tower bolts of extruded section (ISI marked) complete all as specified and directed. 4 Each
32 1.31 Supply & fixing 200 mm size aluminium anodised barrel tower bolts of extruded section (ISI marked) complete all as specified and directed. 4 Each
33 1.32 Supply & fixing extruded aluminium alloy handle fabricated type anodised 100 mm size (ISI marked) complete all as specified and directed. 16 Each
34 1.33 Supply & fixing extruded aluminium alloy handle fabricated type anodised 150 mm size (ISI marked) complete all as specified and directed. 16 Each
35 1.34 S&F 300 mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips or sheets cast of extruded section and fixing bolts and sliding bolts of extruded section ISI marked complete all as specified and directed. 4 Each
36 1.35 Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4 sqm each and removing from the site complete all as specified and directed. 4 Each
37 1.36 Taking down shutter only and re-fixing in same opening after planing, chiselling the shutters of any description exc 1 sq. m but n exc 2 sq. m each complete all as specified and directed. 4 PER LEAF
38 1.37 Supply and fixing 2nd class hard wood plain solid straight chowkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. 0.22 Cum
39 1.38 Supply and fixing 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 8 SQM
40 1.39 Supply and fixing in repair mild steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, with glazing bars, dovetailed or welded complete all as specified and as directed. 12 SQM
41 1.4 M&L for complete removal of existing treatment and applying two Coat of acrylic distemper over and including a layer of 1 mm thick wall putty complete all as specified and as directed. 200 SQM
42 1.41 M&L Preparing old decorated surfaces of Wall and applying one coat of acrylic distemper complete all as specified and as directed. 1000 SQM
43 1.42 M&L Preparing old decorated surfaces of ceiling and applying one coat of acrylic distemper complete all as specified and as directed. 300 SQM
44 1.43 M&L Preparing new surfaces of ceiling board and applying two Coat of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed. 95 SQM
45 1.44 M&L Preparing new plastered surfaces of Wall and applying two Coat of acrylic distemper over one coat of alkali resistant primer complete all as specified and as directed. 150 SQM
46 1.45 M&L 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in sub base of floor complete all as specified and directed. 140 SQM
47 1.46 M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed. 180 KG
48 1.47 M&L for Mild steel, plain, 1.25 mm thick black sheet in wall cladding, steel gates, platform for water tank and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. 85 SQM
49 1.48 S&F Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. \n(Make : Ess Ess, Cat No: C-209 / JAQUAR, Cat No: CON-107KN/ PARRYWARE, Cat No: G1405A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9208 /HINDWARE, Cat No: F330041) 15 Each
50 1.49 M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed. \n 150 SQM
51 1.5 M&L for structural steel work Fe 410-W (Gde-E-250) quality-A in roof trusses (framed), trussed, purlins, crane gantries, rials and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by the Engineer-in-Charge 678 KG
52 1.51 M&L for Rolled mild steel in plates(plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment Gde Fe 410W complete . 22 KG
53 1.52 S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed. 1620 SQM
54 1.53 All as per Item No. 1.52 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof. 102 SQM
55 1.54 S&F rotational moulded polyethylene water storage tanks Water Tank, double layered, ISI marked of capacity 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete, all as specified and directed. 3 EACH
56 1.55 S&F Ball valves 20 mm bore, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms), complete all as specified and directed. \n[MAKE : PRAYAG, Cat No. 152 / POLYTUF, Cat No. 1012(b) or equivalent model in SHAKTI / JEXON] 3 EACH
57 1.56 Supply, laying and testing of 32 mm outer dia, 3- layer PP-R Polypropylene random copolymer) pipes SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed by Engr-in-Charge. 120 RM
58 1.57 Supply, laying and testing of 20 mm outer dia, 3- layer PP-R Polypropylene random copolymer) pipes SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed by Engr-in-Charge. 125 RM
59 1.58 Supply and fixing PPR Gate valve with brass insert and brass working parts suitable for 32 mm OD PPR pipe complete all as specified and directed. 6 EACH
60 1.59 Supply and fixing PPR Gate valve with brass insert and brass working parts suitable for 20 mm OD PPR pipe complete all as specified and directed. 6 EACH
61 1.6 M&L cutting existing steel tubing 25-32 mm bore pipe for addition/alteration and screwing existing steel tubings for addition alteration (each cut measured) complete all as specified and directed. 6 EACH
62 1.61 Screwing existing steel tubing 25-32 mm bore for alterations or additions (or lengthening screw on pipe to form connecton) including insertion of new fittings as required complete all as specified and directed. 3 EACH
63 2 SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION)
64 2.01 Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed. 103 POINT
65 2.02 Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site. 4 EACH
66 2.03 Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.\n(NOTES: - \n(i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same.\n(ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)\n\n 55 POINT
67 2.04 All as per item No. 06 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box). 10 POINT
68 2.05 All as per item No. 06 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box). 30 POINT
69 2.06 All as per item No. 06 above but using 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLSH PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box). 8 POINT
70 2.07 S&F Switch piano, flush type, 5/6 Amps, single pole one way complete all as specified and directed 65 EACH
71 2.08 S&F socket outlet, flush type, 5 pin, 5/6 Amps, complete all as specified and directed 10 EACH
72 2.09 S&F switch socket combination outlet, flush type, 3/5 pins, 5/6 Amps complete all as specified and directed 30 EACH
73 2.1 S&F switch socket combination outlet, flush type 6 in 1, 3 pin, 10/20 Amps with indicator lamp 8 EACH
74 2.11 S&F Ceiling rose, surface type, 3 terminals, 240 Volts complete all as specified and directed 50 EACH
75 2.12 S&F stepped type electronic fan regulator, 5 speed control, 230/240 Volts complete all as specified and directed 10 EACH
76 2.13 S&F lamp holder with back plate, PVC/ Polycarbonate body, suitable for batten/pendant fittings or to be mounted on walls complete all as specified and directed 5 EACH
77 2.14 S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size all as specified and directed. complying with the following specifications:- \n(a) minimum efficacy 110 lumen/watt\n(b) CRI not less than 80, \n(c) THD < 20%\n(d) having in built short circuit and surge protection\n(e) colour temperature not less than 5700 degree K\n(f) life not less than 25000 hours of operation\n(NOTE: List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work) 30 EACH
78 2.15 Taking down ceiling fan 1200 mm to 1400 mm sweep of any make sealing cable ends, dismantling blades, applying one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc, hanging the ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge. \n 10 Each
79 2.16 Taking down exhaust fan 200 mm to 450 mm sweep of any make sealing cable ends, dismantling blades, applying one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc, refixing the same in original position including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge. \n 10 EACH
80 2.17 Supply and fixing TPN DB, IP 43 protection, double door, 415 volts, 4 way (8+12) complete all as specified and directed.\n(MAKE : LEGRAND, Cat No: 5076 70 / L&T, Cat No. DBTPN004DD / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4) 1 Each
81 2.18 Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed.\n(MAKE : LEGRAND, Cat No: 5076 11 /L&T, Cat No. DBSPN008DD / ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08) 2 Each
82 2.19 S&F MCB, 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.\n 1 EACH
83 2.2 S&F SPN DB, IP 43 protection, double door, 240 volts, 4 way complete all as specified and directed.\n(MAKE : LEGRAND, Cat No: 5076 10 / L&T, Cat No. DBSPN004DD / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04) 1 EACH
84 2.21 S&F MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.\n 6 EACH
85 2.22 S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.\n 26 EACH
86 2.23 S&F SPN DB, IP 30 protection, 240 volts, 2 way complete all as specified and directed.\n(MAKE : LEGRAND, Cat No: 507791 / L&T, Cat No. DBENC002SD / C&S, CSDBMCBEDP / ABB, Cat No: SEN2P) 3 EACH
87 2.24 S&F in repair sub main wiring with 2 runs of single core FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl PVC conduit of suitable size complete all as specified and directed.\n(NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)\n 100 RM
88 2.25 S&F sub main wiring with 2 runs of single core FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl PVC casing capping of suitable size complete all as specified and directed.\n(NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)\n 110 RM
89 2.26 Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed. 1 EACH JOB
90 2.27 S&F in repair Bracket/Arm suitable for street light fittings, made out of 32 mm bore (light grade) GI pipe length not exceeding 1.20 metre long, fixed with 02 sets of flat iron clamp of size 32mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge. 3 EACH JOB
91 2.28 Supply and fix in repairs LED Street Light fitting 25W, in pressure die cast aluminium housing with Polycarbonate PMMA lens and toughened glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:-.\n(a) minimum efficacy 110 lumen/watt\n(b) CRI not less than 70, \n(c) THD < 30%\n(c) having in built short circuit and surge protection upto 5 kV\n(d) colour temperature not less than 5700 degree K\n(e) life not less than 50000 hours of operation\n(f) Weather protection grade: IP66\n(NOTE: \n(1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work..\n(2) Wire for electric connection shall be measured and paid separately) 3 EACH
92 2.29 S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 2.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs complete all as specified and as directed by the Engr-in-Charge. 15 RM
93 2.3 Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip armoured heavy duty electric power cable 1100 Volts grade with stranded aluminium conductor cable, of size 4 core 10 sqmm, laid in trench or fixed to wall/passing through pipe/pole complete all as specified and directed.\n 55 RM
94 3 SCHEDULE 'A' PART-III (SOLAR WATER HEATER)
95 3.01 Supply, installation, testing and comissioning of Solar Hot Water System (Flat Plate Collector) of 200 LPD capacity based on indirect transfer of heat including stainless steel back up hot water tank, tank stand, back up PVC cold water tank of capacity 200 litres including electrical backup of 2 KW complete all as specified and directed.\n(MAKE : VENUS, Cat No. 200SFENPR / RACOLD, Model : OMEGA MAX8 or equivalent model in V GUARD / TATA BP SOLAR / SOLAR EXPERTS )\n(NOTE : Cold water tank, cold water piping and hot water piping shall be measured and paid seperately) 3 EACH JOB
96 3.02 Material and labour for hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 40 RM
97 3.03 Material and labour for hot water pipe duly insulated with glass wool and aluminium cladding 25 mm bore complete all as specified and directed. 20 RM