Upgradation Of Ek Nayanar Memorial Government Iti Kayyur On Par Upgradation Of Ek Nayanar Memoria LGovernment Iti Kayyur On Par With InternationalStandards, Kayyur, Kasaragode-Kerala

Kerala Academy for Skills Excellence-KASE has published Upgradation Of Ek Nayanar Memorial Government Iti Kayyur On Par Upgradation Of Ek Nayanar Memoria LGovernment Iti Kayyur On Par With InternationalStandards. Submission Date for this Tender is 08-03-2021. Building Work Tenders in Kayyur, Kasaragode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

27147295
Upgradation Of Ek Nayanar Memorial Government Iti Kayyur On Par Upgradation Of Ek Nayanar Memoria LGovernment Iti Kayyur On Par With InternationalStandards
Open Tender
Indian
Kerala
Kayyur, Kasaragode
08-03-2021

Tender Details

Upgradation Of Ek Nayanar Memorial Government Iti Kayyur On Par Upgradation Of Ek Nayanar Memoria LGovernment Iti Kayyur On Par With InternationalStandards

Key Value

Document Fees
INR 7500 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Work Name : UP GRADATION OF EK NAYANAR MEMORIAL ITI KAYYUR ON PAR WITH INTERNATIONAL STANDARDS.PHASE 1-REV 3
Sl. No. Item Description Item Code / Make Quantity Units
1 1 COVERED COURTS CUM AUDITORIUM CIVIL WORKS 1
2 1.01 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 2 217.704 cum
3 1.02 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil 3 25.617 cum
4 1.03 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 4 119.41 cum
5 1.04 4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 5 69.207 sqm
6 1.05 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 6 445.505 cum
7 1.06 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 7 87.375 cum
8 1.07 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 8 101.924 sqm
9 1.08 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 9 128.667 cum
10 1.09 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 10 216.042 cum
11 1.1 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 11 216.358 sqm
12 1.11 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 12 412.787 sqm
13 1.12 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 13 474.497 sqm
14 1.13 5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 14 282.8 metre
15 1.14 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 15 8350.88 kilogram
16 1.15 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 16 20443 kg
17 1.16 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 17 12.253 cum
18 1.17 od304922/2019_2020 : Providing and laying autoclaved aerated cement blocks masonry with 200 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). 18 167.398 cum
19 1.18 50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 19 2.041 cum
20 1.19 50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete 20 2.824 cum
21 1.2 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 21 1274.51 sqm
22 1.21 13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand) 22 1221.12 sqm
23 1.22 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 23 519.733 sqm
24 1.23 22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for\nwaterproofing treatment to the RCC structures like retaining walls of the basement,\nwater tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels\n/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts\nintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts\nintegral crystalline slurry : 1 part water) for horizontal surfaces and applying the\nsame from negative (internal) side with the help of synthetic fiber brush. The material\nshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing\npermeability of concrete by more than 90% compared with control concrete as per\nDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline\nslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work\nshall be carried out all complete as per specification and the direction of the engineerin-\ncharge. The product performance shall carry guarantee for 10 years against any\nleakage.For vertical surface two coats @0.70 kg per sqm 24 153.36 sqm
25 1.24 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 25 200.228 sqm
26 1.25 11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. 26 22.2 sqm
27 1.26 od14860/2019_2020 : Providing and fixing Mapple wood court for indoor sports using 21 mm thk seasoned mapple wood 57 to 83mm wide and in random length in tongue and groove shapes, 70mmx45mm hard wood runner treated with anti-termite solution and fixed on the bottom side with 19 mm thick air cushioned pads, stapled through the two wings at 330mm x 330mm. Colour - Teak wood. All works covered by this specification shall be carried by an experienced contractor having sufficient experience in this type of work, Only skilled and experienced persons shall be employed for this purpose. 27 450.5 sqm
28 1.27 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 28 116.761 sqm
29 1.28 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 29 1740.86 sqm
30 1.29 13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats 30 1740.86 sqm
31 1.3 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 31 1274.51 sqm
32 1.31 13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works 32 49 sqm
33 1.32 13.84.2 : Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 33 49 sqm
34 1.33 9.147.5 : Providing and fixing factory made uPVC white colour casement/casement cum\nfixed glazed windows comprising of uPVC multi-chambered frame, sash and\nmullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2\nmm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of\nappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction\nhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8\nmm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut\nand fusion welded at all corners, mullion (if required) shall be also fusion welded\nincluding drilling of holes for fixing hardware's and drainage of water etc. After\nfixing frame the gap between frame and adjacent finished wall shall be filled with\nweather proof silicon sealant over backer rod of required size and of approved\nquality, all complete as per approved drawing & direction of Engineer-in-Charge.\n(Single / double glass panes and silicon sealant shall be paid separately)<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm)made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead ofappropriate dimension. (Area of window above 1.50 sqm). 34 48 sqm
35 1.34 9.147B.1 : 543\nSUB HEAD : 9 - WOOD & PVC WORK\n9.147B\nProviding and fixing factory made uPVC white colour fixed glazed windows/\nventilators comprising of uPVC multi-chambered frame and mullion (where ever\nrequired) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized\nmild steel section made from roll forming process of required length (shape &\nsize according to uPVC profile), , uPVC extruded glazing beads of appropriate\ndimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished\nwall, plastic packers, plastic caps and necessary stainless steel screws etc.\nProfile of frame shall be mitred cut and fusion welded at all corners, mullion (if\nrequired) shall be also fusion welded including drilling of holes for fixing\nhardware's and drainage of water etc. After fixing frame the gap between frame\nand adjacent finished wall shall be filled with weather proof silicon sealant over\nbacker rod of required size and of approved quality, all complete as per approved\ndrawing & direction of Engineer-in-Charge. (Single / double glass panes and\nsilicon sealant shall be paid separately).<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.) 35 1 sqm
36 1.35 21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 36 49 sqm
37 1.36 50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. 37 210.836 sqm
38 1.37 od14866/2019_2020 : Providing and fixing MS galvalume coated corrugated sheets roofing system (Proflex or approved equivalent) curved to shape, using required thickness of corrugated MS sheets as per design of the vendor (Proflex or approved equivalent); fixed directly to the RCC gutter at ends using necessary holdfasts etc. and without any structural members supporting the sheets in between the span, all in perfect line, level &amp; plumb. The rate shall include all the laps &amp; wastages etc. complete. Only net laid area shall be measured for payment. Ridges, flashings etc. shall not be paid for separately. All the curving shall be done carefully at the site and the sheets lifted and placed by crane. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise.&lt;br&gt; 38 627.624 sqm
39 1.38 od15276/2019_2020 : Supply and installation of High performance Industrial Roof-Vents(600 mm Dia. self driven roof ventilator) made of aluminum alloy Air Vent, designed to meet AS-2428.1.1993 to wind speed of 200Km/hr and to the entry of wind driven rain at a range of 2.5 L/sec. Under cyclone condition. Roof vents to be fixed on standing seam profile with engineering detail to be designed to make total system as leak proof and to the satisfaction of engineers in-charge. 39 7 each
40 1.39 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 40 833 kg
41 1.4 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 41 843.342 kg
42 1.41 21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 42 9.6 sqm
43 1.42 od268231/2019_2020 : Supply and fixing ready made galvanized wooden texture Powder coating/Heat transfer/Fluorocarbon laminate painted steel doors with steel jamb,SS hinges &amp; door sill ,sheet thickness of 1to 1.4mm, Cylindrical lock, high security locking systems (Multi lock models having 11 locking points, and can be operated with a single key), honeycomb paper Infilling material, five years warranty on all the hardware and locking system as per satisfaction of site Engineer in charge.The above rate included all fixing and fittings like security locks, hinges, hardware items etc.( Cuirass/I-leaf/GM or approved equivalent.) 43 17.28 sqm of door area
44 1.43 od268232/2019_2020 : Supply and fix fully finished Pre Hung Door:-Both side Veneered (Sapeli/ Beech /RC Walnut/RC Teak etc) vertical grains Flush door with matching Veneer Wrapped Engineered wood Jamb (Frame) with front side Architraves and other side Tackers, all with specialised Lacquer Polish. Door of 35 mm thick with 4 side PVC Lipping / Lock Hole Boring (using mortise lock) / Hinge Rebate cutting (4 Nos.) /Extruded Sauerland core / Honey comb core filling. as per drawing and agreed schedule of rates inclusive of all applicable taxes to the satisfaction of site Engineer in charge.The above rate included all fixing and fiting lock, hinges,hardware items etc. ( Jacsons or approved equivalent) 44 8.4 sqm
45 1.44 od268233/2019_2020 : Supply and fix fully finished Pre Hung Door:- Both side HP Laminate vertical grain pattern Flush door with matching PVC wrapped WPC Jamb with front side Architrave other side tackers. Door of 35mm thick with 4 side edges painted / Lock Hole Boring (Using mortise lock)/ Hinge Rebate Cutting (4 Nos) ,Jamb width 100 mm. Latch with Lever handles without Keys SS finish - 1 No, Hinges 4&quot; x 3&quot; x 3mm SS finish - 4 Nos .Tower Bolt 6&quot; SS Finish - 1 No.(Jacsons or Approved equivalent) 45 20.581 sqm of door area
46 1.45 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 46 6 each
47 1.46 17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern 47 4 each
48 1.47 17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 48 4 each
49 1.48 17.8 : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 49 4 each
50 1.49 17.70.1 : Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 50 4 each
51 1.5 17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms 51 6 each
52 1.51 18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore 52 12 each
53 1.52 50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 53 12 no
54 1.53 50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 54 6 no
55 1.54 18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 55 6 each
56 1.55 18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 56 12 each
57 1.56 od288217/2019_2020 : Supply &amp; Fixing stainless steel square cockroach proof traps with Gratings MAT finish. Unloading materials supplied at site and storing it in safe place provided in the site. (Make:CHILLY/ ACO/SGS ) 57 14 each
58 1.57 od288218/2019_2020 : Providing and fixing 75mm dia Cleanout with Spigot, with SS 304 Square Frame &amp; Round Frame with Flat Round Cover with Rubber Seal &amp; SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.(Make:CHILLY/ ACO/SGS ) 58 1 each
59 1.58 od288219/2019_2020 : Providing and fixing 100mm dia Cleanout with Spigot, with SS 304 Square Frame &amp; Round Frame with Flat Round Cover with Rubber Seal &amp; SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.(Make:CHILLY/ ACO/SGS ) 59 3 each
60 1.59 50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 60 61 metre
61 1.6 50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 61 14 metre
62 1.61 50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 62 17.26 metre
63 1.62 50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2 63 6.1 metre
64 1.63 50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 64 5.3 metre
65 1.64 50.18.8.6.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2 65 5.78 metre
66 1.65 50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 66 9 metre
67 1.66 50.18.9.6.2 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 67 4.7 metre
68 1.67 50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 68 9.2 metre
69 1.68 50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 69 6.15 metre
70 1.69 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 70 132.7 metre
71 1.7 od14775/2019_2020 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge 160 mm dia 6 Kgf/cm2 - External work- Exposed on wall 71 263.4 metre
72 1.71 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 72 26.88 metre
73 1.72 od14662/2019_2020 : Extra over for Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round underground PVC pipes. 73 27.705 cum
74 1.73 19.4.3.2 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith sewer bricks conforming to IS: 4885 74 2 each
75 2 MRAC WORKSHOP CIVIL WORKS 75
76 2.01 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 76 95.14 cum
77 2.02 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil 77 5.95 cum
78 2.03 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 78 28.751 cum
79 2.04 4.1.4 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) 79 5.309 cum
80 2.05 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 80 78.875 cum
81 2.06 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 81 68.172 cum
82 2.07 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 33.602 sqm
83 2.08 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 83 10.65 sqm
84 2.09 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 84 210.262 sqm
85 2.1 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 85 13.361 sqm
86 2.11 5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 86 36.92 metre
87 2.12 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 87 28.264 cum
88 2.13 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 88 3666.16 kilogram
89 2.14 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 89 4454.11 kg
90 2.15 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 90 93.627 cum
91 2.16 od304925/2019_2020 : Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 91 3.262 cum
92 2.17 od304922/2019_2020 : Providing and laying autoclaved aerated cement blocks masonry with 200 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). 92 39.88 cum
93 2.18 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 93 10.044 cum
94 2.19 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 94 3.582 cum
95 2.2 13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand) 95 316.053 sqm
96 2.21 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 96 263.075 sqm
97 2.22 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 97 34.222 sqm
98 2.23 od288243/2019_2020 : Mat polished finish on concrete surface by flooring the process &quot;DENSIFIED FLOOR&quot; Vid. as Grinding the concrete floor using Coarse, Medium diamond grinding tools for removing the latency and minor level difference and opening up the pores in concrete, Densification of the floor using hybrid densifier, Densifier reacts with the UN-hydrated lime present in concrete and makes the concrete surface dense and hard.It offers many benefitssuch as reduced dusting, higher gloss readings, increased abrasion resistance, and a longer lifespan of the concrete floor. For this to achieve, the concrete floor is allowed to be saturated with densifier, sealing with external grade sealer is applied on the floor after polishing to protect the floor from the effects of weather and to make the floor water repellent and stain resistant, burnishing the floor using a floor burnisher to bring about more shine and remove excess sealer from the floor etc in compliance to ASTM C-779 - Standard test method for abrasion resistance on horizontal floor surfaces. This item shall be executed only by the agency which has all required manufacturing machinery and necessary expertise. 98 140.16 sqm
99 2.24 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 99 28.315 sqm
100 2.25 11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. 100 7.16 sqm
101 2.26 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 101 22.051 sqm
102 2.27 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 102 613.35 sqm
103 2.28 13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats 103 350.275 sqm
104 2.29 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 104 263.075 sqm
105 2.3 13.84.2 : Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 105 46.572 sqm
106 2.31 od268305/2019_2020 : Supply and install externally 1st quality 600x300x8mm brick pattern design colour ceramic tile wall cladding, tile shall be laid and fixed to pre- plastered walls in patterns, style and forms of grouting and jointing as directed by engineer using approved tile adhesive materials and pointed with approved tile joint filler matching the colour of tiles. 106 2.136 sqm
107 2.32 od268306/2019_2020 : Supply and install externally 1st quality 600x300x8mm ceramic tile walls cladding of cement ash or similar different colours, tile shall be laid and fixed to pre plastered walls in patterns, style and forms of grouting and jointing as directed by engineer using approved tile adhesive materials and pointed with approved tile joint filler matching the colour of tiles. 107 12.15 sqm
108 2.33 od268308/2019_2020 : Supply Cor-Ten A grade 3mm thick warm rolled perforated cassettes (ASTM A606) fixed to plastered wall spacing in the hidden plastic suspension mounts with stainless steel class 108 6.984 sqm
109 2.34 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 109 368.64 kg
110 2.35 9.147.5 : Providing and fixing factory made uPVC white colour casement/casement cum\nfixed glazed windows comprising of uPVC multi-chambered frame, sash and\nmullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2\nmm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of\nappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction\nhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8\nmm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut\nand fusion welded at all corners, mullion (if required) shall be also fusion welded\nincluding drilling of holes for fixing hardware's and drainage of water etc. After\nfixing frame the gap between frame and adjacent finished wall shall be filled with\nweather proof silicon sealant over backer rod of required size and of approved\nquality, all complete as per approved drawing & direction of Engineer-in-Charge.\n(Single / double glass panes and silicon sealant shall be paid separately)<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm)made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead ofappropriate dimension. (Area of window above 1.50 sqm). 110 22.5 sqm
111 2.36 9.147B.1 : 543\nSUB HEAD : 9 - WOOD & PVC WORK\n9.147B\nProviding and fixing factory made uPVC white colour fixed glazed windows/\nventilators comprising of uPVC multi-chambered frame and mullion (where ever\nrequired) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized\nmild steel section made from roll forming process of required length (shape &\nsize according to uPVC profile), , uPVC extruded glazing beads of appropriate\ndimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished\nwall, plastic packers, plastic caps and necessary stainless steel screws etc.\nProfile of frame shall be mitred cut and fusion welded at all corners, mullion (if\nrequired) shall be also fusion welded including drilling of holes for fixing\nhardware's and drainage of water etc. After fixing frame the gap between frame\nand adjacent finished wall shall be filled with weather proof silicon sealant over\nbacker rod of required size and of approved quality, all complete as per approved\ndrawing & direction of Engineer-in-Charge. (Single / double glass panes and\nsilicon sealant shall be paid separately).<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.) 111 0.6 sqm
112 2.37 21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 112 23.1 sqm
113 2.38 od268232/2019_2020 : Supply and fix fully finished Pre Hung Door:-Both side Veneered (Sapeli/ Beech /RC Walnut/RC Teak etc) vertical grains Flush door with matching Veneer Wrapped Engineered wood Jamb (Frame) with front side Architraves and other side Tackers, all with specialised Lacquer Polish. Door of 35 mm thick with 4 side PVC Lipping / Lock Hole Boring (using mortise lock) / Hinge Rebate cutting (4 Nos.) /Extruded Sauerland core / Honey comb core filling. as per drawing and agreed schedule of rates inclusive of all applicable taxes to the satisfaction of site Engineer in charge.The above rate included all fixing and fiting lock, hinges,hardware items etc. ( Jacsons or approved equivalent) 113 4.2 sqm
114 2.39 od268233/2019_2020 : Supply and fix fully finished Pre Hung Door:- Both side HP Laminate vertical grain pattern Flush door with matching PVC wrapped WPC Jamb with front side Architrave other side tackers. Door of 35mm thick with 4 side edges painted / Lock Hole Boring (Using mortise lock)/ Hinge Rebate Cutting (4 Nos) ,Jamb width 100 mm. Latch with Lever handles without Keys SS finish - 1 No, Hinges 4&quot; x 3&quot; x 3mm SS finish - 4 Nos .Tower Bolt 6&quot; SS Finish - 1 No.(Jacsons or Approved equivalent) 114 3.361 sqm of door area
115 2.4 10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover 115 11.52 sqm
116 2.41 10.7 : Providing and fixing ball bearing for rolling shutters. 116 2 no
117 2.42 10.3 : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer . 117 7.2 sqm
118 2.43 od268110/2019_2020 : Providing &amp; fixing Poly carbonate multi wall plain sheet 10 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. 118 7.2 sqm
119 2.44 od268326/2019_2020 : Providing and fixing MS galvalume coated corrugated sheets roofing system (Proflex) curved to shape, using required thickness of corrugated MS sheets as per design of the vendor (Proflex or approved equivalent); fixed directly to the RCC gutter at ends using necessary holdfasts etc. and without any structural members supporting the sheets in between the span, all in perfect line, level &amp; plumb. The rate shall include all the laps &amp; wastages etc. complete. Only net laid area shall be measured for payment. Ridges, flashings etc. shall not be paid for separately. All the curving shall be done carefully at the site and the sheets lifted and placed by crane.This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 119 175.8 sqm
120 2.45 od15276/2019_2020 : Supply and installation of High performance Industrial Roof-Vents(600 mm Dia. self driven roof ventilator) made of aluminum alloy Air Vent, designed to meet AS-2428.1.1993 to wind speed of 200Km/hr and to the entry of wind driven rain at a range of 2.5 L/sec. Under cyclone condition. Roof vents to be fixed on standing seam profile with engineering detail to be designed to make total system as leak proof and to the satisfaction of engineers in-charge. 120 4 each
121 2.46 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 121 2 each
122 2.47 17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern 122 1 each
123 2.48 17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 123 2 each
124 2.49 17.8 : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 124 2 each
125 2.5 17.70.1 : Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 125 2 each
126 2.51 17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms 126 2 each
127 2.52 50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 127 2 no
128 2.53 50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 128 2 no
129 2.54 od288217/2019_2020 : Supply &amp; Fixing stainless steel square cockroach proof traps with Gratings MAT finish. Unloading materials supplied at site and storing it in safe place provided in the site. (Make:CHILLY/ ACO/SGS ) 129 4 each
130 2.55 18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore 130 2 each
131 2.56 18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 131 4 each
132 2.57 50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 132 7.13 metre
133 2.58 50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 133 3.02 metre
134 2.59 50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 134 1.2 metre
135 2.6 50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2 135 3 metre
136 2.61 50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 136 1 metre
137 2.62 50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 137 3.5 metre
138 2.63 50.18.9.6.2 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 138 2.34 metre
139 2.64 50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 139 5 metre
140 2.65 50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 140 4.46 metre
141 2.66 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 141 12.15 metre
142 2.67 od14775/2019_2020 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge 160 mm dia 6 Kgf/cm2 - External work- Exposed on wall 142 67.4 metre
143 2.68 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 143 12.8 metre
144 2.69 od14662/2019_2020 : Extra over for Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round underground PVC pipes. 144 2.097 cum
145 2.7 19.4.3.2 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith sewer bricks conforming to IS: 4885 145 1 each
146 3 FRONT GATE AND SMALL GATE CIVIL WORKS 146
147 3.01 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 147 33.922 cum
148 3.02 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 148 18.365 cum
149 3.03 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 149 3.454 cum
150 3.04 4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 150 6.824 sqm
151 3.05 4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 151 21.6 sqm
152 3.06 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 152 3 sqm
153 3.07 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 153 14.04 sqm
154 3.08 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 154 11.3 sqm
155 3.09 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 155 12.75 sqm
156 3.1 5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 156 20.2 metre
157 3.11 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 157 28.125 kilogram
158 3.12 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 158 610.374 kg
159 3.13 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 159 0.563 cum
160 3.14 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 160 4.327 cum
161 3.15 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 161 14.619 cum
162 3.16 50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 162 40.417 cum
163 3.17 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 163 277.635 sqm
164 3.18 13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand) 164 25.95 sqm
165 3.19 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 165 5.44 sqm
166 3.2 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 166 5.44 sqm
167 3.21 od268305/2019_2020 : Supply and install externally 1st quality 600x300x8mm brick pattern design colour ceramic tile wall cladding, tile shall be laid and fixed to pre- plastered walls in patterns, style and forms of grouting and jointing as directed by engineer using approved tile adhesive materials and pointed with approved tile joint filler matching the colour of tiles. 167 19.576 sqm
168 3.22 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 168 286.209 sqm
169 3.23 13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats 169 286.209 sqm
170 3.24 13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . 170 63.6 sqm
171 3.25 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 171 38.4 kg
172 3.26 9.147.5 : Providing and fixing factory made uPVC white colour casement/casement cum\nfixed glazed windows comprising of uPVC multi-chambered frame, sash and\nmullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2\nmm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of\nappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction\nhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8\nmm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut\nand fusion welded at all corners, mullion (if required) shall be also fusion welded\nincluding drilling of holes for fixing hardware's and drainage of water etc. After\nfixing frame the gap between frame and adjacent finished wall shall be filled with\nweather proof silicon sealant over backer rod of required size and of approved\nquality, all complete as per approved drawing & direction of Engineer-in-Charge.\n(Single / double glass panes and silicon sealant shall be paid separately)<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm)made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead ofappropriate dimension. (Area of window above 1.50 sqm). 172 2.4 sqm
173 3.27 21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 173 2.4 sqm
174 3.28 od268233/2019_2020 : Supply and fix fully finished Pre Hung Door:- Both side HP Laminate vertical grain pattern Flush door with matching PVC wrapped WPC Jamb with front side Architrave other side tackers. Door of 35mm thick with 4 side edges painted / Lock Hole Boring (Using mortise lock)/ Hinge Rebate Cutting (4 Nos) ,Jamb width 100 mm. Latch with Lever handles without Keys SS finish - 1 No, Hinges 4&quot; x 3&quot; x 3mm SS finish - 4 Nos .Tower Bolt 6&quot; SS Finish - 1 No.(Jacsons or Approved equivalent) 174 3.781 sqm of door area
175 3.29 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 175 1377 kg
176 3.3 od309860/2019_2020 : Supply and install 100mmx100mmx14g thick 6.00 m long Galvanized square hollow section member (AS 1163-2009 Grade min C350L0 AS/NZS 4792 Galvanised coatings on ferrous hollow sections) fixed vertically and anchored to RC parapet and base up stand, will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer in-charge for approval before execution). 176 46.2 metre
177 3.31 25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including:a) Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to makeit watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium compositepanel cladding in pan shape in metalic colour of approved shades made out of4mm thick aluminium composite panel material consisting of 3mm thick FR grademineral core sandwiched between two Alumini um sheets (each0.5mm thick). Thealuminium composite panel cladding sheet shall be coil coated, with Kynar500based PVDF / Lumiflon based fluoropolymer resin coating of approved colourand shade on face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backerrods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanisedwith serrations and serrated washers to arrest the wind load movement, fasteners,SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators toprevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost ofall mock ups at site, cost of all samples of the individual components for testing inan approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face ofthe curtain wall with Aluminum Composite Panel Cladding (including width ofgroove) shall be measured in sqm. up to two decimal places. 177 52.3 sqm
178 4 COMPOUND WALL 178
179 4.01 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 179 24.948 cum
180 4.02 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 180 3.565 cum
181 4.03 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 181 7.128 cum
182 4.04 5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size) 182 0.177 cum
183 4.05 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 183 24.641 kg
184 4.06 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 184 14.256 cum
185 4.07 4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 185 23.76 sqm
186 4.08 50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 186 10.231 cum
187 4.09 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 187 121.225 sqm
188 4.1 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 188 121.225 sqm
189 4.11 13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats 189 121.225 sqm
190 4.12 10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 190 431.266 kg
191 4.13 13.84.2 : Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 191 20.936 sqm
192 4.14 od268305/2019_2020 : Supply and install externally 1st quality 600x300x8mm brick pattern design colour ceramic tile wall cladding, tile shall be laid and fixed to pre- plastered walls in patterns, style and forms of grouting and jointing as directed by engineer using approved tile adhesive materials and pointed with approved tile joint filler matching the colour of tiles. 192 11.88 sqm
193 5 INTERNAL ROADS AND PARKING 193
194 5.01 16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 194 1591 sqm
195 5.02 16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge. 195 318.2 cum
196 5.03 51.16.PC.1pb : Primer Coat - Bitumen Emulsion (SS-1) - Using Packed Bitumen Rates <br>\nProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (low porosity). 196 1591 sqm
197 5.04 od14724/2019_2020 : 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately): With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR ITEM NO.16.33.1) 197 2596 sqm
198 5.05 51.16.31.1.2 : Tack Coat - RS Bitumen Emulsion - On bituminous surface @ 0.25 kg /sqm <br> Providing and applying tack coat using bitumen emulsion conforming to IS : 8887, using emulsion pressure distributor including preparing the surface & cleaning with mechanical broom. <br> 1. With Rapid Setting Bitumen Emulsion <br> 2. On bituminous surface @ 0.25 kg /sqm 198 1987 sqm
199 5.06 od14731/2019_2020 : Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG -10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete.(DSR ITEM NO 16.40) 199 1987 sqm
200 6 FOOT PATH, SURFACE DRAINS AND KERBS ETC. 200
201 6.01 od14644/2019_2020 : Providing and laying average 100 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate mixed with sand Zone V, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 201 151.34 sqm
202 6.02 16.42 : Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete 202 15.135 cum
203 6.03 16.45 : Providing and fixing in position pre- moulded joint filler in expansion joints. 203 10215 per cm depth per cm width per meter length
204 6.04 16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) 204 25.718 cum
205 6.05 od14682/2019_2020 : two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 205 68.581 sqm
206 6.06 16.90 : Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 206 272 sqm
207 6.07 od268327/2019_2020 : Construct foundation for lighting pole using M30 concrete of overall size 65x65x160 cm and 4 nos M20x75cm long anchor bolt set in concrete using 4mm thick anchor plate as per the drawing and specification. 207 10 each
208 6.08 od14696/2019_2020 : Construct RC drain using 1:1.5:3 mix wall and base 10cm thick of average inside dimensions 40cm wide x 60cm deep covered with 10cm (1:1.5:3) mix precast RC slab etc as per drawing and specification 208 214 metre
209 7 EXTERNAL WATER SUPPLY 209
210 7.01 50.18.9.5.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 210 27.5 metre
211 7.02 50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 211 181.4 metre
212 7.03 50.18.9.16.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall 212 32 metre
213 7.04 od14711/2019_2020 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling &amp; testing of joints complete as per direction of Engineer in Charge. 63 mm dia 10Kgf/cm2 213 14 metre
214 7.05 od14713/2019_2020 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 10 Kgf/cm2 - External work - Exposed on wall 214 17.7 metre
215 7.06 od14662/2019_2020 : Extra over for Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round underground PVC pipes. 215 8.55 cum
216 7.07 od275595/2019_2020 : Supply, install and testing approved make forged brass ball valves full bore and thread conforming to IS 1703with all necessary fittings &amp; accessories ie, unions, connectors,adapters, PTFE tape etc.complete as directed and specified, 32mm full bore. 216 1 each
217 7.08 od275596/2019_2020 : Supply, install and testing approved make forged brass ball valves full bore and thread conforming to IS 1703with all necessary fittings &amp; accessories ie, unions, connectors,adapters, PTFE tape etc.complete as directed and specified, 40mm full bore.&lt;br&gt; 217 5 each
218 7.09 18.32.1 : Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 \n(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 218 4 each
219 7.1 18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal 219 1 each
220 7.11 od17116/2019_2020 : Supply installation testing and commissioning of water treatment plant 2000 LPH capacity with Pressure Sand filter,Activated Carbon filter, Float switches 2 nos,Filter feed pump (2000 lph,20-25 m head),chemical dosing pump((0-10) lph with all accessories complete as per the direction of engineer in charge 220 1 each
221 8 EXTERNAL SEWERAGE AND RAIN WATER DRAINAGE 221
222 8.01 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 222 23.86 metre
223 8.02 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 223 274.8 metre
224 8.03 od14662/2019_2020 : Extra over for Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round underground PVC pipes. 224 21.997 cum
225 8.04 19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 225 29 each
226 8.05 19.7.2.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 226 4 each
227 8.06 19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 227 4.35 metre
228 8.07 19.8.2.1 : Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 228 0.6 metre
229 8.08 51.19.ST4 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br>\n4. 35 to 50 flush capacity 229 3 each
230 8.09 19.33 : Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. 230 2 each
231 8.1 od17127/2019_2020 : Supply all material and construct RCC rain water filtration tank cum collection tank of overall size 7.6x2.40x2.45m using 1:1.5:3 concrete mix etc. all complete as per the drawing and specification. 231 1 each
232 8.11 od17130/2019_2020 : Supplying and installing ready made Pre cast RCC Water tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (5000 L Capacity ) 232 8 each
233 9 ARCHITECTURAL UP GRADATION 233
234 9.01 14.53.1 : Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work 234 2500 sqm
235 9.02 14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work 235 206 sqm
236 9.03 14.46 : Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 236 2400 sqm
237 10 PLAY GROUND 237
238 10.01 2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 238 9775 sqm
239 10.02 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 239 6 cum
240 10.03 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 240 32 cum
241 10.04 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 241 320.001 sqm
242 10.05 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 242 2512 kilogram
243 10.06 50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. 243 2932.5 cum
244 11 SIGNAGE AND BOARD 244
245 11.01 od275653/2019_2020 : Providing and fixing of Advance Direction / Way finding / Reassurance Sign board of size 1000 mm x 1500 mm made out of Type-XI encapsulated lens type retro reflective sheeting wide. Base Sheeting shall be of White Color type IV class B retro reflective sheeting fixed over 2 mm thick Aluminium Composite Material sheet with area exceeding 0.9 sqm fixed over back support frame of M.S.Angle 35 x 35 x 5 mm all round mounted on two 50 mm dia MS Pipe with clear height of not less than 2.1 m from the ground level to the bottom of the board as per approved drawings.&lt;br&gt;The sign post should be painted with one coat of red oxide paint and two coats of 1 st quality synthetic enamel paint Black &amp; white colour with bands of 30 cm height. The sign post shall be firmly fixed in to the ground by means of properly designed foundation with M15 grade concrete size 450mm x 450mmx 600 mm, including cost,conveyance of all materials, equipment,machinery and labour with all leads and lift,loading charges necessary for satisfactory completion of the work as directed by Engineer in-Charge. 245 2 each
246 11.02 od275654/2019_2020 : Supply and fixing sticker type signage at site (on door or similar locations) in proper line &amp; level. The signage letters shall be made with premium quality vinyl sheet of approved colour, pasted on &ldquo;3M&rdquo;make self-adhesive film of approved colour, including supply of all material labour etc. required for proper completion of work. Before making the signage text &amp; font of letters in best fit size will be set in computer so as to give aesthetic look as per sample available with ITD 246 7980 sqcm
247 11.03 od275655/2019_2020 : Supply and fixing bilingual signage in English. The signage letters will be made with premium quality vinyl sheet of approved colour, pasted on 3mm thick aluminium composite panel backing. The signage will be either fixed on the wall with the screws &amp; double tape or hanged from the false ceiling with the help of hooks &amp; chains complete work. 247 12399.2 sqcm
248 11.04 od275656/2019_2020 : Supply &amp; fixing 5 mm thick aluminum compressed Panel (ACP) sheet in the required size for building name signage. The sheet will be cut into size as per the size of signage to be fixed in position (Stone fa&ccedil;ade, grit wash, gypsum board etc.) with screws &amp; tape including s/o all material labour T&amp;P etc. required for proper completion of work. 248 21000 sqcm
249 11.05 od275657/2019_2020 : Supply &amp; fixing stainless steel (SS) letters made with SS-304 grade 20 gauge sheet as per the approved size &amp; shade including fixing on ACP sheet in required height line &amp; level including s/o all T&amp;P etc. required for proper completion of work. Before making the letters the font &amp; size will be got approved from ITD. 249 19950 sqcm
250 11.06 od275658/2019_2020 : Supply and fixing symbol signage such as No. Smoking, No Spitting, Drinking Water etc. signage of standard sizes as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws &amp; double tape or hanged from the false ceiling with the help of chain &amp; screws etc. complete work. 250 3192 sqcm
251 11.07 od275659/2019_2020 : Printing of floor plans on approx. A2 size poster sheet with indelible ink framing the same in 3mm thick acrylic sheet and 1&rdquo; studs complete. The floor plans will be fixed on the wall with the help of screws and double tape etc. to give neat &amp; finished look 251 5 each
252 12 COVERED COURTS CUM AUDITORIUM ELECTRICAL WORKS 252
253 12.01 od260426/2019_2020 : Supply, Installation, Testing and commissioning of 6 KVA UPS with 1 hourbattery back up complete with all accessories as required 253 1 set
254 12.02 od260443/2019_2020 : Supply of 10 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 254 30 metre
255 12.03 od260448/2019_2020 : Supply of 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 255 3 metre
256 12.04 od260451/2019_2020 : Supply of 25 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 256 86 metre
257 12.05 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) 257 2 set
258 12.06 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 25 sq. mm (28mm) 258 2 set
259 12.07 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm) 259 2 set
260 12.08 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mm 260 81 metre
261 12.09 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 261 31 metre
262 12.1 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 262 250 metre
263 12.11 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm 263 31 metre
264 12.12 2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door 264 1 each
265 12.13 90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 265 1 each
266 12.14 90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 266 1 each
267 12.15 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 267 36 each
268 12.16 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 268 4 each
269 12.17 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 269 1 each
270 12.18 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 270 1 each
271 12.19 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 271 2 each
272 12.2 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 272 1 each
273 12.21 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 273 1 each
274 12.22 od268273/2019_2020 : Supply &amp; Fixing of 25/32 A DP MCB isolator 274 1 each
275 12.23 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 275 280 metre
276 12.24 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 276 220 metre
277 12.25 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 277 15 each
278 12.26 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 278 8 each
279 12.27 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 279 15 each
280 12.28 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 280 8 each
281 12.29 1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 281 1 each
282 12.3 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 282 28 each
283 12.31 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 283 11 each
284 12.32 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 284 6 each
285 12.33 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C 285 68 point
286 12.34 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 286 51 point
287 12.35 od260505/2019_2020 : Supply and laying of one number of 10 SWG Copper wire on wall/ surface/ recessed conduit etc. 287 30 metre
288 12.36 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required 288 2 set
289 12.37 od260416/2019_2020 : Supplying and laying 10 SWG Cu wire at 0.50 metre below ground level for conductor earth&lt;br&gt;electrode, including connection/ termination with GI thimble etc. as required. 289 40 metre
290 12.38 od260472/2019_2020 : Supply, installation , testing and commissioning of Wall fan of 300mm sweep dia on wall, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the Wall fan.&lt;br&gt;300mm sweep wall fan working on 230 V A/C 290 1 each
291 12.39 od260502/2019_2020 : Supply, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.&lt;br&gt;300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C 291 2 each
292 12.4 90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 292 28 each
293 12.41 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 293 24 each
294 12.42 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. 294 24 each
295 12.43 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 295 140 metre
296 12.44 od261417/2019_2020 : Supply, Installation, Testing and commissioning Of distribution box for CCTV 6Ux600Wx600D With Front Glass Door,Side Openable Panels with Lock &amp; Key,4Way 5A PDU,1U Cable Manager,Cooling Fan,H/W Kit10 296 1 no
297 12.45 od261212/2019_2020 : &nbsp;SITC Of 350W RMS MIXER AMPLIFIER, 3 MIC, 2 AUX, 100V/70V AND 4OHMS , BALANCED MIC,FREQUENCY RESPONSE (50 HZ-16000HZ),S/N RATIO-MIC1,2,3,4:66DB;AUX 1:80 DB,THD-LESS THAN 1% AT 1 KHZ,1/3 RATED POWER, MUTING FUNCTION-MIC 1 OVERRIDES OTHER INPUT SIGNALS WITH 0-30 DB ATTENUATION,CONTROLS-INDIVIDUAL GAIN CONTROLS, POWER SWITCH;BASS: 10DB AT 100HZ,TREBLE: 10DB AT10000HZ. 297 1 each
298 12.46 od261213/2019_2020 : Supply, Installation, Testing and commissioning of XLR cables and connectors 298 6 each
299 12.47 od261214/2019_2020 : Supply &amp; laying of twin twisted 2x1.5 sqmm Cu flexible wire 1.1 kv grade PVC insulated through PVC conduit. 299 110 metre
300 12.48 od261215/2019_2020 : Supply, installation, testing and commissioning of indoor IR IP dome camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity, with IR n 480 TV lines. 300 4 each
301 12.49 od261216/2019_2020 : Supply, installation, testing and commissioning of Outdoor IR IP bullet camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity,with IR 480TV lines. 301 1 each
302 12.5 od261705/2019_2020 : Supply and laying of Cat6 outdoor cable including necessary connectors&lt;br&gt; 302 50 metre
303 12.51 od261605/2019_2020 : Supply, installation, testing and commissioning of 24&quot; Monitor for CCTV 303 1 no
304 12.52 od261606/2019_2020 : SITC Of NVR 8 Channel for CCTV 304 1 no
305 12.53 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. 305 2 each
306 12.54 od260393/2019_2020 : Supply, installation, testing and commissioning of LAN socket. 306 4 no
307 12.55 od260518/2019_2020 : Supply, installation, testing and commissioning of 16W wall mount speaker 86db/W 307 7 no
308 12.56 od260498/2019_2020 : Supply, installation, testing and commissioning of 5W LED wall light working on 230V, 50 Hz AC, including giving connections as required. 308 22 each
309 12.57 od260520/2019_2020 : SITC of Rust Resistant and Weather-Proof Bulk head light fixture with 9W LED lamp, IP 65 protection complete with all other accessories as required. 309 4 no
310 12.58 od261703/2019_2020 : SITC of D-Link (DIR-878) AC1900 MU-MIMO 1900Mbps Wi-Fi Router (Without Modem) 310 1 each
311 12.59 od260521/2019_2020 : SITC of 50W high bay light working on 230V 50Hz AC supply for indoor purpose complete with all other accessories as required 311 40 each
312 13 COVERED COURTS CUM AUDITORIUM FIRE FIGHTING WORKS 312
313 13.01 od262941/2019_2020 : (Kayyur) 7.7: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required :&lt;br&gt;100mm dia pipe 313 12 per metre
314 13.02 od262942/2019_2020 : (Kayyur) 11.5 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with&lt;br&gt;bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets&lt;br&gt;conforming to IS 13095 of following sizes as required :100mm dia 314 5 each
315 13.03 od262943/2019_2020 : (Kayyur )9.2: Supplying and fixing single headed internal hydrant valve with instantaneous&lt;br&gt;Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming&lt;br&gt;to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 315 1 each
316 13.04 od261901/2019_2020 : Supply, installing, testing and commissioning of Fire Extinguisher dry chemical&lt;br&gt;powder type ISI mark, 5 kg capacity with initial charger and&lt;br&gt;installation&lt;br&gt;brackets.Make - Safex / Warrior / Intime 316 6 each
317 13.05 od263978/2019_2020 : (Kayyur) 16.2: Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female&lt;br&gt;couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) (Sythetic fibre circular woven jackated rubber lined fire hose delivery having 38Kg. Per Cm. Sq. burst pressure,&lt;br&gt;28Kg. Per Cm. proof pressure, 14Kg. Per Cm. working&lt;br&gt;pressure as per IS:636 (ISI Marked) Type A in 15 Meters&lt;br&gt;length, 63mm dia duly copper via bounded two coupling&lt;br&gt;pair of male female parts any duly intantanous type,&lt;br&gt;63mm size as per IS:903 (ISI Marked)) 317 1 each
318 13.06 od260392/2019_2020 : Providing 63mm (2&frac12; )&quot; dia 15 m long canvas hose pipe complete with stainless steel male &amp; female coupling stainless steel wire wound with the pipe The pipe shall confirm to IS. 4927. Make: ISI Approved. 318 1 each
319 13.07 od260400/2019_2020 : M.S Hose Cabinet : - Providing &amp; fixing M.S Hose cabinet door with powdercoating of postal red color (of size minimum 1200mm wide, 2100mm height) madeof M.S sheet 14 G with glass front door and locking arrangement to accommodate2-hoses, one branch pipe and to accommodate F.A. hose reel in addition forinternal hydrant complete as per direction of Engineer incharge 319 1 each
320 13.08 od260406/2019_2020 : Providing and fixing 63 mm dia standard stainless steel short Branch Pipe female instantaneous inlet, male threaded outlet, complete with hexagonal base nozzle as per IS 903 with 20 mm nozzle complete with fixing clamps. Make: Essel/Priyanka/Newage 320 1 each
321 13.09 od260415/2019_2020 : Providing and fixing Fire Man axe as required with Test Certificate of 20,000 volts.Make : - ISI Approved.&lt;br&gt;&lt;br&gt;&lt;br&gt; 321 1 each
322 13.1 od260418/2019_2020 : ESCAPE ROUTE SIGNS :- Supply &amp; installing in position self glowing &quot; EXIT &quot; sign board to guide the occupants towards the exits of size 100mm x 300 mm made of luminescent safely, rigid sheet in green colour, photo luminescent rigid sheet with two each hanging chains &amp; necessarry supports to hang it on&lt;br&gt;ceiling. 322 5 each
323 13.11 od260423/2019_2020 : FIRE EXIT :- Supply &amp; installing in position self glowing &quot; FIRE EXIT &quot; sign board of size 100mm x 300 mm made of luminescent safely, rigid sheet in green colour, photo luminescent rigid sheet with two each hanging chains &amp; necessarry supports to hang it on ceiling. 323 2 each
324 14 MRAC WORKSHOP ELECTRICAL WORKS 324
325 14.01 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 325 18 metre
326 14.02 1.20.3 : Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess\nincluding painting in case of surface conduit, or cutting the wall and making good the same in\ncase of recessed conduit as required.32 mm 326 18 metre
327 14.03 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mm 327 45 metre
328 14.04 90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 328 1 each
329 14.05 90.11.1.21 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 329 1 each
330 14.06 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door 330 1 each
331 14.07 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 331 1 each
332 14.08 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 332 1 each
333 14.09 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 333 26 each
334 14.1 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 334 1 each
335 14.11 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 335 4 each
336 14.12 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 336 1 each
337 14.13 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 337 1 each
338 14.14 2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 338 2 each
339 14.15 2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 339 2 each
340 14.16 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C 340 20 point
341 14.17 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 341 4 point
342 14.18 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 342 210 metre
343 14.19 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 343 95 metre
344 14.2 1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire 344 40 metre
345 14.21 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 345 15 each
346 14.22 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 346 6 each
347 14.23 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 347 15 each
348 14.24 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 348 6 each
349 14.25 1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push 349 1 each
350 14.26 od268273/2019_2020 : Supply &amp; Fixing of 25/32 A DP MCB isolator 350 1 each
351 14.27 od268274/2019_2020 : Supplying and fixing 40A rating, 240/415 volts, &quot;C&quot; curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.&nbsp;&lt;br&gt;Triple pole 351 1 each
352 14.28 1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 352 1 each
353 14.29 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 353 2 each
354 14.3 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 354 15 each
355 14.31 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 355 3 each
356 14.32 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 356 2 each
357 14.33 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. 357 2 each
358 14.34 90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 358 9 each
359 14.35 od260500/2019_2020 : Supply, installation , testing and commissioning of Wall fan of 400mm sweep dia on wall, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the Wall fan.&lt;br&gt;400mm sweep wall fan working on 230 V A/C 359 6 each
360 14.36 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 360 3 each
361 14.37 od260502/2019_2020 : Supply, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.&lt;br&gt;300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C 361 2 each
362 14.38 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. 362 2 each
363 14.39 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required 363 2 set
364 14.4 od260505/2019_2020 : Supply and laying of one number of 10 SWG Copper wire on wall/ surface/ recessed conduit etc. 364 8 metre
365 14.41 od260416/2019_2020 : Supplying and laying 10 SWG Cu wire at 0.50 metre below ground level for conductor earth&lt;br&gt;electrode, including connection/ termination with GI thimble etc. as required. 365 18 metre
366 14.42 od261895/2019_2020 : Supply of 10 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 366 8 metre
367 14.43 od260451/2019_2020 : Supply of 25 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 367 50 metre
368 14.44 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) 368 2 set
369 14.45 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 25 sq. mm (28mm) 369 2 set
370 14.46 od260528/2019_2020 : Supply, installation, testing and commissioning of 40W LED low bay light for indoor working on 230V 50Hz AC complete with all other accessories as required. 370 6 each
371 14.47 od268298/2019_2020 : SITC of 6KVA UPS with 12V 42Ah battery for 1 hour back-up complete with all&lt;br&gt;accessories as required. 371 1 each
372 15 MRAC WORKSHOP FIRE FIGHTING WORKS 372
373 15.01 od260381/2019_2020 : Supply, installing, testing and commissioning of Fire Extinguisher Carbondi oxide type ISI mark, 2 kg capacity with initial charger and installation brackets.Make:- ISI Approved. 373 2 each
374 15.02 od263388/2019_2020 : (Kayyur) Below Ground Piping :- Providing, fixing, welding joints and testing of 100 mm Dia. heavy class MS ERW Black pipes as per relevant IS 1239/3589 with special accessories tees, elbows, flanged joints, rubber insertion, nuts, bolts, washers or welded joint with flange joints on bends, including fixing the pipe with suitable flat iron strip clamps/brackets structural members dash fastener,civil breakage,making good the same etc. painting with a primer coat and two coats of postal red enamel etc. complete as required. (for wet riser system)&lt;br&gt; 374 137 per metre
375 15.03 od263389/2019_2020 : (Kayyur)4.1P: Supplying, installation, testing and commissioning of electric driven terrace pump suitable&lt;br&gt;for automatic operation and consisting of following, complete in all respects, as required:&lt;br&gt;(Terrace Pump)&lt;br&gt;Horizontal type, multistage, centrifugal, split casing pump of cast iron body &amp; bronze&lt;br&gt;impeller with stainless steel shaft, mechanical confirming to IS : 1520&lt;br&gt;Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3&lt;br&gt;phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted&lt;br&gt;type with Class-&apos;F&apos; insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as&lt;br&gt;required.&lt;br&gt;Suitable cement concrete foundation duly plastered and with anti vibration pads. 900lpm @ 35 m head 375 1 each
376 15.04 od262941/2019_2020 : (Kayyur) 7.7: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required :&lt;br&gt;100mm dia pipe 376 12 per metre
377 15.05 od263390/2019_2020 : (Kayyur(14.5) Providing, installation, testing and commissioning of non-return valve of following sizes&lt;br&gt;confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia 377 2 each
378 15.06 od263391/2019_2020 : (Kayyur ) 19.1 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male&lt;br&gt;instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe&lt;br&gt;connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe&lt;br&gt; 378 1 each
379 15.07 od263392/2019_2020 : (Kayyur) Providing &amp; fixing 25mm Air release valve as per IS:14845 ISI Marked 379 1 each
380 15.08 od263393/2019_2020 : (Kayyur) 22 : Providing &amp; fixing of pressure switch in M.S. pipe line including connection etc. as required. 380 1 each
381 15.09 od261901/2019_2020 : Supply, installing, testing and commissioning of Fire Extinguisher dry chemical&lt;br&gt;powder type ISI mark, 5 kg capacity with initial charger and&lt;br&gt;installation&lt;br&gt;brackets.Make - Safex / Warrior / Intime 381 2 each
382 15.1 90.14.28.2 : S & F Motor starters of the following ratings 382 1 each
383 15.11 od260428/2019_2020 : Providing &amp; fixing pressure gauges of not less than 100mm dia dial of pressure range 0-10 kg/cmsq complete with shut off valve duly calibrated before installation.Make:- ISI Approved.&lt;br&gt; 383 1 each
384 15.12 od260446/2019_2020 : 3 core cable,2.5sq mm,copper. Make:- ISI approved 384 30 metre
385 16 FRONT GATE AND SMALL GATE M AND E WORKS 385
386 16.01 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 386 12 each
387 16.02 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 387 1 each
388 16.03 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 388 1 each
389 16.04 90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 389 1 each
390 16.05 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C 390 28 point
391 16.06 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 391 4 each
392 16.07 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 392 4 each
393 16.08 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 393 2 each
394 16.09 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 394 6 point
395 16.1 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 395 100 metre
396 16.11 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 396 20 metre
397 16.12 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 397 12 metre
398 16.13 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 398 2 each
399 16.14 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 399 2 each
400 16.15 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 400 2 each
401 16.16 7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm 401 9 metre
402 16.17 7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing masonry open duct as required.Upto 35 sq. mm 402 35 metre
403 16.18 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mm 403 70 metre
404 16.19 14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with\nRCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia 404 9 metre
405 16.2 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 405 25 metre
406 16.21 od260472/2019_2020 : Supply, installation , testing and commissioning of Wall fan of 300mm sweep dia on wall, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the Wall fan.&lt;br&gt;300mm sweep wall fan working on 230 V A/C 406 2 each
407 16.22 od260481/2019_2020 : Supply and laying of one number of 10 SWG Copper wire in the existing trench along with power cables. 407 30 metre
408 16.23 od260484/2019_2020 : Supply of 1.5 sqmm 3 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part If for XLPE 408 20 metre
409 16.24 od261895/2019_2020 : Supply of 10 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 409 80 metre
410 16.25 od261901/2019_2020 : Supply, installing, testing and commissioning of Fire Extinguisher dry chemical&lt;br&gt;powder type ISI mark, 5 kg capacity with initial charger and&lt;br&gt;installation&lt;br&gt;brackets.Make - Safex / Warrior / Intime 410 2 each
411 16.26 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) 411 2 set
412 16.27 od261924/2019_2020 : Supply &amp; Installation of Draw Boxes with termination 412 7 each
413 16.28 od261925/2019_2020 : SITC of 3W LED Recessed Spot light pre wired, working on 230V, 50Hz AC, complete with all other accessories as required. 413 4 no
414 16.29 od261926/2019_2020 : SITC of 20/25W LED Surface mounting down light, working on 230V, 50Hz AC, complete with all other accessories as required. 414 2 no
415 16.3 od261927/2019_2020 : SITC of weather proof pillar light fittings with 9W LED lamp, IP65 for outdoor purpose pre wired and complete with all other accessories as required. 415 12 no
416 16.31 od261928/2019_2020 : Supply, installation, testing and commissioning of LED 3W Spike light, IP65 with all other accessories as required. 416 4 no
417 16.32 90.6.5.19 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 417 28 metre
418 16.33 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 418 13 metre
419 16.34 od260498/2019_2020 : Supply, installation, testing and commissioning of 5W LED wall light working on 230V, 50 Hz AC, including giving connections as required. 419 2 each
420 16.35 od261960/2019_2020 : Supply of 4 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 420 35 metre
421 17 EXTERNAL LIGHTING 421
422 17.01 7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm 422 16 metre
423 17.02 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mm 423 250 metre
424 17.03 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 424 80 metre
425 17.04 14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with\nRCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia 425 16 metre
426 17.05 od260416/2019_2020 : Supplying and laying 10 SWG Cu wire at 0.50 metre below ground level for conductor earth&lt;br&gt;electrode, including connection/ termination with GI thimble etc. as required. 426 25 metre
427 17.06 od260449/2019_2020 : Supply of 4 sqmm 3 core PVC/ XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 427 240 metre
428 17.07 od261821/2019_2020 : Supply of 16 sqmm 3 core PVC/ XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 428 90 metre
429 17.08 9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 X 16 sq. mm (25mm) 429 2 set
430 17.09 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required 430 2 set
431 17.1 od260457/2019_2020 : SITC of 5 metre Hot dipped galvanised Octogonal pole in single section with 70mm top diameter, 130mm bottom diameter, 3mm sheet thickness, base plate dimensions of 200 x 200x 12 mm with 1.0 M long single arm bracket with 36W LED street light complete with all other accessories as required. 431 4 each
432 17.11 od260460/2019_2020 : SITC of 6 metre Hot dipped galvanised Octogonal pole in single section with 70mm top diameter, 130mm bottom diameter, 3mm sheet thickness, base plate dimensions of 200 x 200x 12 mm with 1.0 M long single arm bracket with 45W LED street light complete with all other accessories as required. 432 6 each
433 17.12 od260463/2019_2020 : SITC Of feeder pillar complete with the following accessories. Incomer: 40A, DP&lt;br&gt;Isolator. 40A, DP, RCCB, 100mA. Timer control with contactor. Auto/ Manual&lt;br&gt;switch. Outgoing: 10A, SP MCB - 4 Nos. 433 1 each
434 17.13 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 434 70 metre
435 17.14 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 435 80 metre
436 18 EXTERNAL FIRE PROTECTION SYSTEM 436
437 18.01 od260392/2019_2020 : Providing 63mm (2&frac12; )&quot; dia 15 m long canvas hose pipe complete with stainless steel male &amp; female coupling stainless steel wire wound with the pipe The pipe shall confirm to IS. 4927. Make: ISI Approved. 437 6 each
438 18.02 od264260/2019_2020 : Kayyur 11.6 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with&lt;br&gt;bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets&lt;br&gt;conforming to IS 13095 of following sizes as required : 150mm dia 438 2 each
439 18.03 od264261/2019_2020 : (Kayyur) 7.6: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required : 80mm dia 439 12 per metre
440 18.04 od264262/2019_2020 : (Kayyur) 14.4 : Providing, installation, testing and commissioning of non-return valve of following sizes&lt;br&gt;confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80mm dia 440 1 each
441 18.05 od264263/2019_2020 : (Kayyur) 7.8: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required : 150mm dia 441 12 metre
442 18.06 od264264/2019_2020 : (Kayyur) 7.1: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required: 25mm dia 442 6 metre
443 18.07 od264265/2019_2020 : (Kayyur) 2.9: Supplying, installation, testing and commissioning of diesel engine driven main fire pump&lt;br&gt;suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS&lt;br&gt;standard complete with auto starting mechanism, 12 /24 volts electric starting equipment,&lt;br&gt;diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm&lt;br&gt;thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,&lt;br&gt;instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.&lt;br&gt;M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 443 1 each
444 18.08 od264266/2019_2020 : (Kayyur) 1.9: Supplying, installation, testing and commissioning of&lt;br&gt;Electric driven Main Fire Pump suitable for automatic&lt;br&gt;operation and consisting of following, complete in all&lt;br&gt;respects, as required :&lt;br&gt;(a) Horizontal type, multistage, centrifugal, split casing&lt;br&gt;pump of cast iron body &amp; bronze impeller with stainless&lt;br&gt;steel shaft, mechanical seal conforming to IS 1520.&lt;br&gt;(b) Suitable HP Squirrel cage induction motor, TEFC,&lt;br&gt;synchronous speed 1500 RPM, suitable for operation&lt;br&gt;on 415 volts, 3 phase 50 Hz, AC supply with IP 55&lt;br&gt;protection for enclosure, horizontal foot mounted type&lt;br&gt;with Class-&apos;F&apos; insulation, conforming to IS-325.&lt;br&gt;(c) M.S. fabricated Common base plate, coupling, coupling&lt;br&gt;guard, foundation bolts etc. as required.&lt;br&gt;(d) Suitable cement concrete foundation duly plastered &lt;br&gt;1620 lpm at 56 m Head 444 1 each
445 18.09 od269363/2019_2020 : Fire Pump Panel: SITC of Fire Pump Panel : Supply, installation , testing and commissioning of totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction M.V. panel board free standing fabricated with14swg and 16swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing&lt;br&gt;switchgear etc. (all feeder unit Would be compartmentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, (bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having current density of 2A / sqmm of suitable capacity &amp; size with lugs from busbar to&lt;br&gt;switchgears / MCCB / MCB or where ever required, control wiring with 1 sqmm FRLS cable, ON/OFF, RYB phase indicators, two earthing terminal busbar of size 25 x 5 mm copper with nut &amp; bolts at outside of the panel, rating and name plates for all incoming &amp; outgoings etc. comprising with the followings as per the KEI standard. Switch gears &ndash; ABB/ Equivalent, Contactors &ndash; ABB, L&amp;T/Equivalent.&lt;br&gt;Incomer: 160A TPN Isolator - 1 no, Outgoing: 100A&lt;br&gt;TPN Isolator - 1 no. &amp; 25 3P MCB-1 No. 445 1 each
446 18.1 od263388/2019_2020 : (Kayyur) Below Ground Piping :- Providing, fixing, welding joints and testing of 100 mm Dia. heavy class MS ERW Black pipes as per relevant IS 1239/3589 with special accessories tees, elbows, flanged joints, rubber insertion, nuts, bolts, washers or welded joint with flange joints on bends, including fixing the pipe with suitable flat iron strip clamps/brackets structural members dash fastener,civil breakage,making good the same etc. painting with a primer coat and two coats of postal red enamel etc. complete as required. (for wet riser system)&lt;br&gt; 446 155 per metre
447 18.11 od264439/2019_2020 : Kayyur 3.1: Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)&lt;br&gt;Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with&lt;br&gt;stainless steel shaft, mechanical seal conforming to IS : 1520.&lt;br&gt;Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3&lt;br&gt;phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot&lt;br&gt;mounted type with Class-&apos;F&apos; insulation, conforming to IS : 325.&lt;br&gt;M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. &lt;br&gt;180 lpm at 88 m Head 447 1 each
448 18.12 od264461/2019_2020 : Kayyur 19.2: Supplying and fixing of fire brigade connection of cast iron body with gun metal male&lt;br&gt;instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe&lt;br&gt;connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe 448 1 each
449 18.13 od262941/2019_2020 : (Kayyur) 7.7: Providing, laying, testing &amp; commissioning of &apos;C&apos; class heavy duty MS pipe conforming to IS&lt;br&gt;3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets&lt;br&gt;etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with&lt;br&gt;two or more coats of synthetic enamel paint of required shade complete as required :&lt;br&gt;100mm dia pipe 449 18 per metre
450 18.14 od263390/2019_2020 : (Kayyur(14.5) Providing, installation, testing and commissioning of non-return valve of following sizes&lt;br&gt;confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia 450 2 each
451 18.15 od263392/2019_2020 : (Kayyur) Providing &amp; fixing 25mm Air release valve as per IS:14845 ISI Marked 451 1 each
452 18.16 od263393/2019_2020 : (Kayyur) 22 : Providing &amp; fixing of pressure switch in M.S. pipe line including connection etc. as required. 452 3 each
453 18.17 od262942/2019_2020 : (Kayyur) 11.5 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with&lt;br&gt;bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets&lt;br&gt;conforming to IS 13095 of following sizes as required :100mm dia 453 5 each
454 18.18 od264618/2019_2020 : Kayyur 11.4: Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with&lt;br&gt;bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets&lt;br&gt;conforming to IS 13095 of following sizes as required&lt;br&gt;80mm 454 2 each
455 18.19 od264485/2019_2020 : Kayyur 10.2: Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required:&lt;br&gt;Single headed Stainless steel 455 6 each
456 18.2 od260434/2019_2020 : Below Ground Piping :- Providing, fixing, welding joints and testing of 150 mm Dia. heavy class MS ERW Black pipes as per relevant IS 1239/3589 with special accessories tees, elbows, flanged joints, rubber insertion, nuts, bolts, washers or welded joint with flange joints on bends, including fixing the pipe with suitable flat iron strip clamps/brackets structural members dash fastener,civil breakage,making good the same etc. painting with a primer coat and two coats of postal red enamel etc. complete as required. (for wet riser system) 456 286 metre
457 18.21 od260445/2019_2020 : Below Ground Piping :- Providing, fixing, welding joints and testing of 80 mm Dia. heavy class MS ERW black pipes as per relevant IS 1239/3589 with special accessories tees, elbows, flanged joints, rubber insertion, nuts, bolts, washers or welded joint with flange joints on bends, including fixing the pipe with suitable flat iron strip clamps/brackets structural members dash fastener,civil breakage,making good the same etc. painting with a primer coat and two coats of postal red enamel etc. complete as required. (for wet riser system) 457 8 metre
458 18.22 od260428/2019_2020 : Providing &amp; fixing pressure gauges of not less than 100mm dia dial of pressure range 0-10 kg/cmsq complete with shut off valve duly calibrated before installation.Make:- ISI Approved.&lt;br&gt; 458 3 each
459 18.23 od260400/2019_2020 : M.S Hose Cabinet : - Providing &amp; fixing M.S Hose cabinet door with powdercoating of postal red color (of size minimum 1200mm wide, 2100mm height) madeof M.S sheet 14 G with glass front door and locking arrangement to accommodate2-hoses, one branch pipe and to accommodate F.A. hose reel in addition forinternal hydrant complete as per direction of Engineer incharge 459 6 each
460 18.24 od260406/2019_2020 : Providing and fixing 63 mm dia standard stainless steel short Branch Pipe female instantaneous inlet, male threaded outlet, complete with hexagonal base nozzle as per IS 903 with 20 mm nozzle complete with fixing clamps. Make: Essel/Priyanka/Newage 460 6 each
461 18.25 od260485/2019_2020 : Providing and fixing Testing arrangement in the pump house comprising one no. 50mm dia. GM ball valve and 10RM of 50mm dia MS pipe (C Class) confirming to IS 1239.&lt;br&gt;Make :- ISI Approved. 461 1 each
462 19 EXISTING SMART CLASSROOM ELV &amp; ELECTRICAL WORKS 462
463 19.01 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 463 13 each
464 19.02 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 464 320 metre
465 19.03 od261267/2019_2020 : Supply, installation, testing and commissioning of Bio Metric Finger Print scan attendance system with LCD/LED display &amp; keypad &amp; TCPIP LAN, USB Connectivity along with Attendance monitoring &amp; report software (Web based Terminal)&lt;br&gt; 465 13 each
466 19.04 od261268/2019_2020 : Supply, Installation, Testing and commissioning of 6W Wall mount speakers with perforated metal grille with line matching transformer suitable for 4 ohm impedance 200 mm dia LBD 0606/10 466 13 each
467 19.05 od261214/2019_2020 : Supply &amp; laying of twin twisted 2x1.5 sqmm Cu flexible wire 1.1 kv grade PVC insulated through PVC conduit. 467 120 metre
468 19.06 od261215/2019_2020 : Supply, installation, testing and commissioning of indoor IR IP dome camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity, with IR n 480 TV lines. 468 26 each
469 19.07 od261270/2019_2020 : Supply, installation, testing, and commissioning of LT Projector and roof mount for LT projector complete with all accessories as required. 469 13 set
470 19.08 od261271/2019_2020 : Supply, installation, testing and commissioning of Promethean Board AB2T78 complete with all other accessories. Active inspire software will be complimentary with Promethean board. 470 13 no
471 19.09 od261484/2019_2020 : Supply, installation, testing and commissioning of LAN socket. 471 13 each
472 19.1 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 472 24 each
473 19.11 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 473 1 each
474 19.12 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 474 1 each
475 19.13 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 475 320 metre
476 19.14 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 476 250 metre
477 19.15 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 477 26 each
478 19.16 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 478 13 each
479 19.17 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 479 26 each
480 19.18 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 480 13 each
481 19.19 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 481 13 each
482 19.2 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 482 13 each
483 19.21 90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 483 1 each
484 19.22 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm) 484 2 set
485 19.23 od260448/2019_2020 : Supply of 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE 485 30 metre
486 20 THE ELV SYSTEM 486
487 20.01 od261417/2019_2020 : Supply, Installation, Testing and commissioning Of distribution box for CCTV 6Ux600Wx600D With Front Glass Door,Side Openable Panels with Lock &amp; Key,4Way 5A PDU,1U Cable Manager,Cooling Fan,H/W Kit10 487 5 no
488 20.02 od261212/2019_2020 : &nbsp;SITC Of 350W RMS MIXER AMPLIFIER, 3 MIC, 2 AUX, 100V/70V AND 4OHMS , BALANCED MIC,FREQUENCY RESPONSE (50 HZ-16000HZ),S/N RATIO-MIC1,2,3,4:66DB;AUX 1:80 DB,THD-LESS THAN 1% AT 1 KHZ,1/3 RATED POWER, MUTING FUNCTION-MIC 1 OVERRIDES OTHER INPUT SIGNALS WITH 0-30 DB ATTENUATION,CONTROLS-INDIVIDUAL GAIN CONTROLS, POWER SWITCH;BASS: 10DB AT 100HZ,TREBLE: 10DB AT10000HZ. 488 1 each
489 20.03 od262010/2019_2020 : Supply, Installation, Testing and commissioning of Distribution box for PA distribution made out of 16 SWG CRCA sheet with lockable door arrangement having connectors (10 NOS) suitable for 1.5sqmm wire with facity for cable termination of 4cx10 sqmm ALAR. Required at each floor for PA wire termination. 489 1 each
490 20.04 od262045/2019_2020 : Supply Installation testing and Commissioning of 10/100/1000 Mbps 24 Port Network Switch to provide networks and internet on class room etc 490 1 each
491 20.05 od261267/2019_2020 : Supply, installation, testing and commissioning of Bio Metric Finger Print scan attendance system with LCD/LED display &amp; keypad &amp; TCPIP LAN, USB Connectivity along with Attendance monitoring &amp; report software (Web based Terminal)&lt;br&gt; 491 1 each
492 20.06 od261705/2019_2020 : Supply and laying of Cat6 outdoor cable including necessary connectors&lt;br&gt; 492 990 metre
493 20.07 od261268/2019_2020 : Supply, Installation, Testing and commissioning of 6W Wall mount speakers with perforated metal grille with line matching transformer suitable for 4 ohm impedance 200 mm dia LBD 0606/10 493 3 each
494 20.08 od262046/2019_2020 : Supply, installation, testing and commissioning of 24 Port 10/100/1000 Mbps PoE Switch. 494 1 each
495 20.09 od261213/2019_2020 : Supply, Installation, Testing and commissioning of XLR cables and connectors 495 6 each
496 20.1 od261214/2019_2020 : Supply &amp; laying of twin twisted 2x1.5 sqmm Cu flexible wire 1.1 kv grade PVC insulated through PVC conduit. 496 180 metre
497 20.11 od261215/2019_2020 : Supply, installation, testing and commissioning of indoor IR IP dome camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity, with IR n 480 TV lines. 497 4 each
498 20.12 od261216/2019_2020 : Supply, installation, testing and commissioning of Outdoor IR IP bullet camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity,with IR 480TV lines. 498 9 each
499 20.13 od262047/2019_2020 : Network Video Recorder:&lt;br&gt;Providing &amp; fixing Network Video Recorde 32-channel 720P or 24-channel 1080P high definition network video input and storage Support simultaneous HDMI and VGA output, resolution up to 1920&times;1080P/60Hz Supports 256Mbps bandwidth throughput handling, Supports 4-channe, 1080P video real-time decoding and synchronous playback Supports 8 SATA hard disk with capacity up to 4TB. 499 1 each
500 20.14 od262048/2019_2020 : Supply, installation, testing and commissioning of 32&quot; Flat Screen VGA Color Monitor.&lt;br&gt; 500 1 each
501 20.15 od262049/2019_2020 : Supply, Installation, testing and commissioning of Cat6 24 Port un loaded Patch Panel. 501 1 each
502 20.16 od262071/2019_2020 : Supply, installation, testing and commissioning of Cat6 I/O for Patch Panel Shuttered. 502 24 each
503 20.17 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 503 150 metre