| Work Name : Development of Government Medical College Pariyaram- Kannur District | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | SUB STRUCTURE | |||
| 2 | 1.01 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 1559.44 | sqm | |
| 3 | 1.02 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 13325.9 | cum | |
| 4 | 1.03 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 667.966 | cum | |
| 5 | 1.04 | od129301/2020_2021 : cost for 1st 50 <br>addl. lead of 100 meters m or part thereof beyond1st 50 m up to 0.50<br>km | 11196.7 | cum | |
| 6 | 1.05 | od129302/2020_2021 : Supplying and filling in plinth with quarry dust under floors, including watering, ramming consolidating and dressing complete. | 550.609 | cum | |
| 7 | 1.06 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 361.649 | cum | |
| 8 | 1.07 | 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level | 2042.77 | cum | |
| 9 | 1.08 | 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). | 2042.77 | cum | |
| 10 | 1.09 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 1322.4 | sqm | |
| 11 | 1.1 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 134.448 | sqm | |
| 12 | 1.11 | 50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete | 30.028 | cum | |
| 13 | 1.12 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 349038 | kilogram | |
| 14 | 1.13 | 22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 168.176 | sqm | |
| 15 | 1.14 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 3500.14 | cum | |
| 16 | 2 | SUPER STRUCTURE | |||
| 17 | 2.01 | 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level | 3656.84 | cum | |
| 18 | 2.02 | 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). | 2820.58 | cum | |
| 19 | 2.03 | 5.34.3 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-40 grade concrete instead of M-25 grade BMC/RMC.(Note : Cementcontent considered in M-40 is @ 360 kg/cum). | 700.584 | cum | |
| 20 | 2.04 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 4537.19 | sqm | |
| 21 | 2.05 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 4056.8 | sqm | |
| 22 | 2.06 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 8691.11 | sqm | |
| 23 | 2.07 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 9310.99 | sqm | |
| 24 | 2.08 | 5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | 264.639 | sqm | |
| 25 | 2.09 | 5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | 8253.36 | sqm | |
| 26 | 2.1 | 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | 448309 | kg | |
| 27 | 2.11 | 50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. | 1532.29 | cum | |
| 28 | 2.12 | 50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete | 363.323 | cum | |
| 29 | 2.13 | 50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | 237.107 | cum | |
| 30 | 3 | CIVIL FINISHING WORK | |||
| 31 | 3.01 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 31824.2 | sqm | |
| 32 | 3.02 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | 11985.6 | sqm | |
| 33 | 3.03 | 13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. | 13963.3 | sqm | |
| 34 | 3.04 | 13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster | 3344.18 | sqm | |
| 35 | 3.05 | 13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 21972.8 | sqm | |
| 36 | 3.06 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 37594.4 | sqm | |
| 37 | 3.07 | 13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats | 36129.1 | sqm | |
| 38 | 3.08 | 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 6155.6 | sqm | |
| 39 | 3.09 | 22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for\nwaterproofing treatment to the RCC structures like retaining walls of the basement,\nwater tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels\n/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts\nintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts\nintegral crystalline slurry : 1 part water) for horizontal surfaces and applying the\nsame from negative (internal) side with the help of synthetic fiber brush. The material\nshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing\npermeability of concrete by more than 90% compared with control concrete as per\nDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline\nslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work\nshall be carried out all complete as per specification and the direction of the engineerin-\ncharge. The product performance shall carry guarantee for 10 years against any\nleakage.For vertical surface two coats @0.70 kg per sqm | 1089.19 | sqm | |
| 40 | 3.1 | 22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 3750.38 | sqm | |
| 41 | 3.11 | 4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) | 349.878 | cum | |
| 42 | 3.12 | YARD FINISHING | |||
| 43 | 3.13 | 16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | 279 | sqm | |
| 44 | 3.14 | 16.78.2 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBRValue-25 | 279 | cum | |
| 45 | 3.15 | 16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks\nin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,\nthickness & size/ shape, made by table vibratory method using PU mould, laid in\nrequired colour & pattern over 50mm thick compacted bed of sand, compacting and\nproper embedding/laying of inter locking paver blocks into the sand bedding layer\nthrough vibratory compaction by using plate vibrator, filling the joints with sand and\ncutting of paver blocks as per required size and pattern, finishing and sweeping\nextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. | 1860 | sqm | |
| 46 | 4 | Finishing work 1 | |||
| 47 | 4.01 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 993.415 | sqm | |
| 48 | 4.02 | 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc | 20543.3 | kg | |
| 49 | 4.03 | 11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement | 424.825 | sqm | |
| 50 | 4.04 | 11.41.3 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm | 7777.34 | sqm | |
| 51 | 4.05 | 11.46.3 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800 x 800 mm | 1555.46 | sqm | |
| 52 | 4.06 | od34678/2020_2021 : Providing and laying anti skid Ceramic floor tiles of size 400x400 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. | 464.551 | sqm | |
| 53 | 4.07 | 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | 1414.09 | sqm | |
| 54 | 4.08 | 11.48.1 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 500x500 mm | 1414.09 | sqm | |
| 55 | 4.09 | 8.13.1 : Providing and laying Polished Granite stone flooring in required design and\npatterns, in linear as well as curvilinear portions of the building all complete as\nper the architectural drawings with 18 mm thick stone slab over 20 mm (average)\nthick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with\ncement slurry and pointing with white cement slurry admixed with pigment of\nmatching shade including rubbing , curing and polishing etc. all complete as\nspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent. | 661.301 | sqm | |
| 56 | 4.1 | 8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work | 574.63 | metre | |
| 57 | 4.11 | od36412/2020_2021 : Providing and fixing textured wall tiles (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete | 424.379 | sqm | |
| 58 | 4.12 | 12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process. | 7414.78 | sqm | |
| 59 | 4.13 | 10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | 2584.56 | kg | |
| 60 | 4.14 | 25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml” | 564.766 | sqm | |
| 61 | 4.15 | od36829/2020_2021 : Providing frameless patch fitting toughened glass swing door for all dimension<br>,providing 12mm thick toughened glass including providing 1'dia brushed steel door handles by<br>providing appropriate holes in 12mm glass ,providing heavy duty floor spring and pivot including fixing<br>in position,including the cost of all patches, fixtures and fittings etc. complete to specification | 43.911 | sqm | |
| 62 | 4.16 | 21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | 6015.78 | kg | |
| 63 | 4.17 | 21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | 16546.8 | kg | |
| 64 | 4.18 | 21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness | 1095.97 | sqm | |
| 65 | 4.19 | 21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness | 300.171 | sqm | |
| 66 | 4.2 | od38346/2020_2021 : Providing and fixing Aluminium composite panel 4mm thick for aluminium doors with necessary screws, beedings etc complete | 148.448 | per sqm | |
| 67 | 4.21 | 9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm | 553.106 | metre | |
| 68 | 4.22 | 9.118.3 : Providing and fixing to existing door frames25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with and average wall thickness of 1 mm ( ± 0.3 mm). PVC foam end cap of size 23x10 mm area provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end -cap of the size 25 mm x 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer,s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. | 208.835 | sqm | |
| 69 | 4.23 | 10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover | 63.979 | sqm | |
| 70 | 4.24 | 10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured). | 63.979 | sqm | |
| 71 | 4.25 | 10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area | 63.979 | sqm | |
| 72 | 4.26 | 21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete | 188 | each | |
| 73 | 4.27 | 9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | 230 | no | |
| 74 | 4.28 | 14.34 : Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete | 230 | no | |
| 75 | 4.29 | 9.74.3 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm | 563 | no | |
| 76 | 4.3 | 21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium | 106 | no | |
| 77 | 4.31 | od38497/2020_2021 : Providing trellies work 15x15cm alumimnium tubular sections spaced at 1.5m vertical intervals fixed to the walls/columns/beams by providing necessary pre-fixed aluminium sections , providing 15x10cm sections fixed every 10cm horizontal intervals, ensuring proper fixing with vertical sections providing bracing and clamping the same for resistance to wind pressure etc. complete including all scaffolding tray, networking scaffolding and all necessary scaffolding for the smooth completion of the works inclusive of all material and labour transportation charges and all handling charges etc. complete as per specification. <br> | 135 | sqm | |
| 78 | 4.32 | od38467/2020_2021 : :Providing MS fabricated canopy 14m long and 8m wide using 150mmx75mmx1.4mm<br>section of approximate 120x90cm grids, providing 11.52mm thick toughened and laminated glass( 5mm clear<br>toughened glass +1.52 PVB +5mm clear toughened glass) fixed VHB on both sides, tapes, silicon etc.<br>including two priming coat of metal primer, insulation at site including welding joints, providing 4 nos steel<br>rod with tensioner, supports from column, beam at 45 degrees with minimum slope for water drainage ,<br>ensure proper fixing to beam/column etc. complete as per specification.<br> | 112.661 | per sqm | |
| 79 | 4.33 | 10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 6426 | kg | |
| 80 | 4.34 | od157735/2020_2021 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. | 476 | sqm | |
| 81 | 5 | Sump | |||
| 82 | 5.01 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 1042.02 | cum | |
| 83 | 5.02 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 273.92 | cum | |
| 84 | 5.03 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 437.731 | cum | |
| 85 | 5.04 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 49.449 | cum | |
| 86 | 5.05 | od257519/2020_2021 : Extra for additives and admixtures<br>Note: For concrete having Compressive strength below 25 MPa<br> | 49.449 | cum | |
| 87 | 5.06 | 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level | 270.205 | cum | |
| 88 | 5.07 | 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). | 167.308 | cum | |
| 89 | 5.08 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 745.458 | sqm | |
| 90 | 5.09 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 1045.81 | sqm | |
| 91 | 5.1 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 259.851 | sqm | |
| 92 | 5.11 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 28365.4 | kilogram | |
| 93 | 5.12 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | 796.638 | sqm | |
| 94 | 5.13 | 22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) | 796.638 | sqm | |
| 95 | 5.14 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 199.837 | cum | |
| 96 | 5.15 | od129297/2020_2021 : Supplying and fixing C.I cover with frame for manholes: 500mm dia C.I cover<br>(medium duty ) the weight of the cover to be no less than 58 kg | 14 | set | |
| 97 | 5.16 | 19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design | 60 | each | |
| 98 | 6 | SANITARY FIXTURES AND CP FITTINGS | |||
| 99 | 6.01 | 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid | 77 | each | |
| 100 | 6.02 | 17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps | 10 | each | |
| 101 | 6.03 | od259972/2020_2021 : Providing & Fixing of colour vitreous china counter top wash basin- installed on granite/ marble with CI / MS brackets, 32mm dia CP waste coupling with plug and chain, PVC / CPcold watersupply connecting pipe, one nos of 15mm dia CP angle stop cock for cold watersupply liness with wall flange etc as per IS specification make and approved by the consultant. The works shall include cutting in walls and making good the walls & floors. .(Granite / Marble counter will be installed by other agency) | 41 | each | |
| 102 | 6.04 | 17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap | 52 | each | |
| 103 | 6.05 | 17.16A : Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge | 77 | no | |
| 104 | 6.06 | 17.7.5 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap | 9 | each | |
| 105 | 6.07 | 17.7.9 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked | 3 | each | |
| 106 | 6.08 | 17.7.11 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI - 304 (18/8) Wash basin 530 x 345 mm with single 15mm C.P. brass pillar tap | 5 | each | |
| 107 | 6.09 | 17.22B : Providing and fixing CP Brass Single lever telephonic wall mixer of quality& make as approved by Engineer in charge.(a) 15 mm nominal dia | 22 | no | |
| 108 | 6.1 | od169729/2020_2021 : Providing and fixing CP Soap Dish Holder having concealed fittings arrangements. | 50 | each | |
| 109 | 6.11 | od169749/2020_2021 : Providing and fixing CP towel rail complete with brackets fixed to Wall with CP brass screws with concealed fitting arrangement of approved quality and colour<br>450 mm long towel rail . | 22 | each | |
| 110 | 6.12 | 17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm | 13 | each | |
| 111 | 6.13 | 17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm | 6 | each | |
| 112 | 6.14 | od169670/2020_2021 : Providing and fixing CP Waste Coupling for wash basin and sink, of approved quality and colour.<br>Waste coupling-full threaded 32mm size | 119 | each | |
| 113 | 6.15 | 17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge. | 26 | each | |
| 114 | 6.16 | 17.75 : Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. | 26 | each | |
| 115 | 6.17 | 18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore | 299 | each | |
| 116 | 6.18 | 17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.\nwaste fittings complete.Semi rigid pipe32 mm dia | 112 | each | |
| 117 | 6.19 | 17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | 103 | each | |
| 118 | 6.2 | od170095/2020_2021 : Providing and fixing PTMT Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge | 103 | each | |
| 119 | 6.21 | od170042/2020_2021 : Providing and fixing CP towel rail complete with brackets fixed to Wall with CP brass screws with concealed fitting arrangement of approved quality and colour<br>600 mm long towel rail . | 45 | each | |
| 120 | 6.22 | od170090/2020_2021 : Providing and fixing CP towel ring trapezoidal shape 215 mm long, 200 mm<br>wide with minimum distances of 37 mm from wall face with concealed fittings<br>arrangement of approved quality and colour. | 75 | each | |
| 121 | 6.23 | 18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore | 8 | each | |
| 122 | 6.24 | od304911/2019_2020 : Providing & fixing, testing and commissioning of approved make & coloured urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications. | 26 | each | |
| 123 | 6.25 | od304913/2019_2020 : Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet, Plastic Cistern , Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge. | 1 | each | |
| 124 | 6.26 | od266076/2020_2021 : Providing and fixing of approved make CP grab bar wall mounted 600mm long with CP flanges, fixed with SS screws complete for all patient Toilet. | 15 | each | |
| 125 | 6.27 | od266077/2020_2021 : Providing and fixing of approved make CP grab bar wall mounted 350mm long with CP flanges, fixed with SS screws complete for all patient Toilet. | 15 | each | |
| 126 | 6.28 | od304914/2019_2020 : Fixing of superior quality Rob hook with brackets and flange with concealed brass screws etc as per IS specification make and approved by the client / consultant, including cutting & making good the walls. | 103 | each | |
| 127 | 6.29 | od299805/2020_2021 : Providing & fixing, testing and commissioning of approved make CP shower unit with concealed part for concealed stop cock suitable for 20mm pipe line with inner head with out exposed parts with 230mm long bend pipe for overhead shower with CP wall flanges | 2 | each | |
| 128 | 6.3 | PART B : WATER SUPPLY (INTERNAL AND EXTERNAL ):CPVC,UPVC PIPES AND FITTNGS | |||
| 129 | 6.31 | 18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes | 410 | metre | |
| 130 | 6.32 | 18.9.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes | 410 | metre | |
| 131 | 6.33 | 18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes | 150 | metre | |
| 132 | 6.34 | 18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes | 18 | metre | |
| 133 | 6.35 | 18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes | 12 | metre | |
| 134 | 6.36 | od305218/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.Make:Supreme / Finolex<br> 20 mm nominal outer dia pipes | 250 | metre | |
| 135 | 6.37 | od305419/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.Make:Supreme / Finolex<br>25 mm diameter sch 40 | 200 | metre | |
| 136 | 6.38 | od305420/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.Make:Supreme / Finolex<br>32 mm dia sch 40<br> | 90 | metre | |
| 137 | 6.39 | od305427/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.Make:Supreme / Finolex<br>40 mm dia sch 40 | 40 | metre | |
| 138 | 6.4 | od305428/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.Make:Supreme / Finolex<br>65mm dia such 4o | 450 | metre | |
| 139 | 6.41 | od305429/2019_2020 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.<br>50 mm dia sch 40<br> | 211 | metre | |
| 140 | 6.42 | 18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore | 86 | no | |
| 141 | 6.43 | 18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore | 36 | each | |
| 142 | 6.44 | 18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore | 8 | each | |
| 143 | 6.45 | 18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore | 4 | each | |
| 144 | 6.46 | 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore | 15 | each | |
| 145 | 6.47 | 18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore | 6 | each | |
| 146 | 6.48 | 18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal | 1 | each | |
| 147 | 6.49 | 18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal | 4 | each | |
| 148 | 6.5 | 18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal | 2 | each | |
| 149 | 6.51 | 18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore | 190 | each | |
| 150 | 6.52 | 18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore | 2 | each | |
| 151 | 6.53 | od305468/2019_2020 : Providing, fixing, testing and commissioning of brass body nickel plated automatic air release valves with necessary GI Specials, thread, holdtight, brass spindle, NBR and elastomeric, stainless steel spring polypropylenic float at the top most points of water supply distribution ring main. 20 mm dia. | 35 | each | |
| 152 | 6.54 | od305505/2019_2020 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 40 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>100mm dia | 4 | each | |
| 153 | 6.55 | od305506/2019_2020 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 40 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>80mm diaq | 4 | each | |
| 154 | 6.56 | od305507/2019_2020 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 40 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>65mm dia | 4 | each | |
| 155 | 6.57 | od305508/2019_2020 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 40 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>50 mm dia | 6 | each | |
| 156 | 6.58 | od305544/2019_2020 : Supplying, and fixing of approved make at site GI Slotted Rail Brackets,hangers,c clamp supports with necessary drilling holes to suit the fitting of pipe clamps, deburring etc.,as per detailed drawing for supporting soil, waste & rain water pipes & water supply pipes in shafts and ceiling with suitable GI clamps,bolts,anchor bolts nuts & washers fixed on shaft walls/outer walls etc with 6mm / 8mm dia full threaded GI rod.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer. | 1431 | each | |
| 157 | 6.59 | od305545/2019_2020 : Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump.<br>25mm dia | 4 | each | |
| 158 | 6.6 | od266088/2020_2021 : Supply & Fixing of hot Water Pipe Insulation With Performed Closed Cell Nitrite Ruber Pipe Section insulation having density not less than 60 kg/cm2 and \"k\" value not more than 0.034 w/m deg. K @ 20 Deg c mean temperature jointing as per manufacture recommendations, 20mm dia insulation | 75 | metre | |
| 159 | 6.61 | od266089/2020_2021 : Supply & Fixing of hot Water Pipe Insulation With Performed Closed Cell Nitrite Ruber Pipe Section insulation having density not less than 60 kg/cm2 and \"k\" value not more than 0.034 w/m deg. K @ 20 Deg c mean temperature jointing as per manufacture recommendations, 50mm dia insulation | 280 | metre | |
| 160 | 7 | PVC SOIL,WASTE,VENT PIPES AND FITTINGS ( INTERNAL & EXTERNAL)\t\t | |||
| 161 | 7.01 | 50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 | 320 | metre | |
| 162 | 7.02 | 50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 | 275 | metre | |
| 163 | 7.03 | 50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 | 240 | metre | |
| 164 | 7.04 | 50.18.9.8.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 | 72 | metre | |
| 165 | 7.05 | 50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | 45 | metre | |
| 166 | 7.06 | 50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | 261 | metre | |
| 167 | 7.07 | 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | 36 | metre | |
| 168 | 7.08 | 50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 | 42 | metre | |
| 169 | 7.09 | 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 | 240 | metre | |
| 170 | 7.1 | od305724/2019_2020 : Providing and fixing of floor traps (4'') to toilet floors and making good the concrete floor as per direction of engineer in charge<br>110mm dia <br> | 130 | each | |
| 171 | 7.11 | 18.58.2.1 : Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating | 130 | each | |
| 172 | 7.12 | 19.4.1.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 16 | each | |
| 173 | 7.13 | 18.37.1 : Constructing masonry chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for water meter complete with C.I double flap surface box 400x200x200 mm ( inside ) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 | 14 | each | |
| 174 | 7.14 | 19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 20 | each | |
| 175 | 7.15 | 19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 | 7 | metre | |
| 176 | 7.16 | od305734/2019_2020 : Providing and fixing soil, waste and vent pipes: 110 mm dia, cowel | 32 | each | |
| 177 | 7.17 | od305736/2019_2020 : Providing and fixing soil, waste and vent pipes: 75 mm dia, cowel | 13 | each | |
| 178 | 7.18 | od305759/2019_2020 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>110 mm dia | 50 | each | |
| 179 | 7.19 | od305766/2019_2020 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>75 mm dia | 35 | each | |
| 180 | 7.2 | PVC RAIN WATER PIPES AND FITTINGS | |||
| 181 | 7.21 | 50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall | 48 | metre | |
| 182 | 7.22 | 50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall | 240 | metre | |
| 183 | 7.23 | 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | 30 | metre | |
| 184 | 7.24 | 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 | 190 | metre | |
| 185 | 7.25 | od259962/2020_2021 : Supply ,fixing ,testing and comissioning of PVC rain water khurra with C.I grating The quoted rate shall include necessary grouting the base of Khurras with aproved sealent complete. | 20 | each | |
| 186 | 7.26 | od305905/2019_2020 : Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials.<br>RCC slabs (For Wash Basin, EWC & Floor Trap) 150 mm thick<br>50mm dia | 25 | each | |
| 187 | 7.27 | od305906/2019_2020 : Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials.<br>RCC slabs (For Wash Basin, EWC & Floor Trap) 150 mm thick<br>63mm dia | 1 | each | |
| 188 | 7.28 | od305907/2019_2020 : Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials.<br>RCC slabs (For Wash Basin, EWC & Floor Trap) 150 mm thick<br> 75mm dia | 5 | each | |
| 189 | 7.29 | od305908/2019_2020 : Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials.<br>RCC slabs (For Wash Basin, EWC & Floor Trap) 150 mm thick<br>110mm dia <br> | 20 | each | |
| 190 | 8 | FIRE PUMPS, VALVES & ACCESSORIES | |||
| 191 | 8.01 | od304850/2019_2020 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :<br>Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze<br>impeller with stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered with anti vibration pads.. a) Electrical Driven Fire Pump <br>Flow - 2280 @85 m<br>Motor – Suitable HP/ 1500 RPM/ 3 Ph | 2 | each | |
| 192 | 8.02 | od304866/2019_2020 : Supplying, installation, testing and commissioning of electric driven pressurisation pump<br>suitable for automatic operation and consisting of following, complete in all respects, as<br>required : (Jockey Pump)<br>Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with<br>stainless steel shaft, mechanical seal conforming to IS : 1520.<br>Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3<br>phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot<br>mounted type with Class-'F' insulation, conforming to IS : 325.<br>M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads.<br>a) Electrical Driven Jockey Pump :<br>Flow - 180 lpm @ 85 m<br>Motor – Suitable HP/2900 RPM/ 3 Ph | 2 | each | |
| 193 | 8.03 | od304867/2019_2020 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump<br>suitable for automatic operation and consisting of following, complete in all respects, as<br>required : (Diesel Driven Pump)<br>Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with<br>stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.<br>M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads.a) Diesel Engine Driven Main Fire Pump<br>Flow - 2280 @85 m<br>Motor – Suitable HP/ 1500 RPM/ 3 P | 1 | each | |
| 194 | 8.04 | od304877/2019_2020 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 150 sq mm on wall, floor | 24 | metre | |
| 195 | 8.05 | od304878/2019_2020 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 25 sq mm on wall, floor | 24 | metre | |
| 196 | 8.06 | 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) | 24 | metre | |
| 197 | 8.07 | 7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | 24 | metre | |
| 198 | 8.08 | 9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 X 25 sq. mm (25mm) | 8 | set | |
| 199 | 8.09 | 9.1.15 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 X 150 sq. mm (50mm) | 8 | set | |
| 200 | 8.1 | od304919/2019_2020 : Supplying, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200 mm dia | 1 | each | |
| 201 | 8.11 | od304926/2019_2020 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 200 mm dia | 1 | each | |
| 202 | 8.12 | od304927/2019_2020 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.150 mm dia | 12 | each | |
| 203 | 8.13 | od305550/2019_2020 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.100 mm dia | 2 | each | |
| 204 | 8.14 | od305579/2019_2020 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. .80 mm dia<br> | 2 | each | |
| 205 | 8.15 | od305643/2019_2020 : Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2 200 mm dia | 1 | each | |
| 206 | 8.16 | od305649/2019_2020 : Supplying, installation, testing and commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm 150 mm dia<br> | 5 | each | |
| 207 | 8.17 | od305666/2019_2020 : Supplying, installation, testing and commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2 -100 mm dia<br> | 2 | each | |
| 208 | 8.18 | od305672/2019_2020 : Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2:-80 mm dia<br> | 2 | each | |
| 209 | 8.19 | od305678/2019_2020 : Supply,Installation, Testing and Commissioning of Air cushion tank (air-vessel) 250 mm dia. x 1.5 M high with dished top, made of minimum 6 mm thick M.S. pipe/plate complete with 25 mm dia. Brass Air Valve (Ball valve, pressure gauge type), 25 mm dia. Stop with brass stop cock, nipple, tees, elbow, pipe, drain valve and all accessories as required incl. fixing brackets. | 1 | each | |
| 210 | 8.2 | od312394/2019_2020 : Supply,Installation,Testing and Commissioning of Pressure switch bellow type of approved make. | 5 | each | |
| 211 | 8.21 | od312850/2019_2020 : Supply, Installation,Testing and Commissioning of Pressure gauge with 0 to 200PSI,25 mm dia. | 2 | each | |
| 212 | 8.22 | od305707/2019_2020 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings.-25 mm dia | 20 | each | |
| 213 | 8.23 | od305710/2019_2020 : Supplying, fixing, testing and commissioning of following NON - RETURN VALVE of C I body vulcanized NBR seal flanged end & PN16 pressure rating as specified -25 mm dia | 5 | each | |
| 214 | 8.24 | od128599/2020_2021 : Supply,Installation, testing & commissioning of installation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MSpipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150 MM Dia | 1 | each | |
| 215 | 8.25 | HYDRANT SYSTEM | |||
| 216 | 8.26 | od305714/2019_2020 : Supply,Installation, Testing and Commissioning of GM single headed Hydrant Valve 80mm inlet with single outlet fitted with 63mm instantaneous female coupling on the outlet complete with flange as required blank cap and chain. Conforming to IS:5290 and of ISI mark. for internal | 13 | each | |
| 217 | 8.27 | od305720/2019_2020 : Supply,Installation, Testing and Commissioning of GM single headed Hydrant Valve 80mm inlet with single outlet fitted with 63mm instantaneous female coupling on the outlet complete with flange as required blank cap and chain. Conforming to IS:5290 and of ISI mark. for external | 6 | each | |
| 218 | 8.28 | od305722/2019_2020 : Supply & Installation of GM short branch pipe conforming to IS: 903 of I S I mark with 63 mm dia instantaneous coupling on one end and nozzle spray or fog type. | 19 | each | |
| 219 | 8.29 | od305727/2019_2020 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses,and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside. | 19 | each | |
| 220 | 8.3 | od305728/2019_2020 : Supply, installation, testing and commissioning of 63mm dia 15 M long non percolating flexible and light weight synthetic fire fighting delivery hose with textile reinforcement, resistant to chemicals, acids, alkalis, abrasions, heat and ozone having 36Kg/cm 2 burst pressure including gunmetal make and instantaneous type coupling approved by fire authority, machine would with copper wire complete in all respects. | 38 | each | |
| 221 | 8.31 | od305731/2019_2020 : Supply,Installation, Testing and Commissioning of swing type Hose reel drum made of 16 gauge MS sheet to keep 19 mm dia 30 Mtrs long PVC lined rubber braded hose pipe with chrome plated nozzle on one end and all other necessary fixing materials | 13 | each | |
| 222 | 8.32 | od305735/2019_2020 : Supply, installation, testing and commissioning of 150mm dia Fire Brigade Inlet connection with 3 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type in a 16 swg Ms cabinet size 1000 x 300 x 400 . | 1 | each | |
| 223 | 8.33 | od305740/2019_2020 : Supply,Installation,Testing and Commissioning of Air Release Valve GM 20mm dia type of approved make. | 6 | each | |
| 224 | 8.34 | od305760/2019_2020 : Hydrant valve Chamber: Brick masonry chambers in cement mortar 1:5 (1 cement: 5 Coarse sand) on cement concrete foundations 150mm thick 1:4:8 mix (1 cement: 4 fine sand: 8 graded stone aggregate 40mm nominal size) 15mm thick cement plaster inside and outside finished with a floating coat of neat cement inside with cast iron surface box approved by local fire brigade including excavation, back filling complete. Valve chambers shall be of following sizes:<br>For depths up to 1mtr. 450mm X 450mm<br>For depths up to 1mtr. & beyond 1000mm X 1000mm | 1 | each | |
| 225 | 8.35 | HYDRANT PIPE | |||
| 226 | 8.36 | od305847/2019_2020 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.150 mm dia | 246 | metre | |
| 227 | 8.37 | od305848/2019_2020 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.80 mm dia | 12 | metre | |
| 228 | 8.38 | od313088/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata200 mm dia | 12 | metre | |
| 229 | 8.39 | od313198/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 80 mm dia | 12 | metre | |
| 230 | 8.4 | od313199/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 100 mm dia | 12 | metre | |
| 231 | 8.41 | od313200/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 150 mm dia | 335 | metre | |
| 232 | 8.42 | FIRE SPRINKLER SYSTEM | |||
| 233 | 8.43 | od313575/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 100 mm dia | 205 | metre | |
| 234 | 8.44 | od313576/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 80 mm dia | 200 | metre | |
| 235 | 8.45 | od313648/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 65 mm dia | 240 | metre | |
| 236 | 8.46 | od313649/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 50 mm dia | 215 | metre | |
| 237 | 8.47 | od313652/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 40 mm dia | 213 | metre | |
| 238 | 8.48 | od313653/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 32 mm dia | 121 | metre | |
| 239 | 8.49 | od313654/2019_2020 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 25 mm dia | 2075 | metre | |
| 240 | 8.5 | od305915/2019_2020 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 80 mm dia | 2 | each | |
| 241 | 8.51 | od305916/2019_2020 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 100 mm dia | 10 | each | |
| 242 | 8.52 | od128315/2020_2021 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 10, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.above 150 mm dia limit switches 50 mm dia<br> | 12 | each | |
| 243 | 8.53 | od305917/2019_2020 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 16, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.above 150 mm dia limit switches 80 mm dia | 2 | each | |
| 244 | 8.54 | od305918/2019_2020 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 16, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.above 150 mm dia limit switches 100 mm dia | 10 | each | |
| 245 | 8.55 | od305919/2019_2020 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas.Upright sprinkler type | 391 | each | |
| 246 | 8.56 | od305920/2019_2020 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 79 degree Celsius. K 80 for other areas. Pendant type sprinkler | 20 | each | |
| 247 | 8.57 | od305921/2019_2020 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas. Sidewall sprinkler type | 40 | each | |
| 248 | 8.58 | od305922/2019_2020 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas. Pendant type sprinkler | 680 | each | |
| 249 | 8.59 | od305933/2019_2020 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200mm <br> | 195 | each | |
| 250 | 8.6 | od305934/2019_2020 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm <br> | 195 | each | |
| 251 | 8.61 | od258316/2020_2021 : Supplying, installation, testing & commissioning of sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and<br>DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass. | 13 | each | |
| 252 | 8.62 | FIRE ALARMS (ADDRESSABLE) SYSTEM | |||
| 253 | 8.63 | od305970/2019_2020 : Supply,Installation,Testing and Commissioning of Intelligent Addressable Heat Detector with base.The detector shall be suitable for both rate of rise and fixed temperature. | 14 | each | |
| 254 | 8.64 | od306008/2019_2020 : Supply, installation, testing and commissioning of Hooter at different locations complete with all fixing accessories, etc. under false ceiling, roof, wall, etc, with a time delay of max 30sec, interconnecting loop cable complete as required. | 14 | each | |
| 255 | 8.65 | od306009/2019_2020 : Supply, Installation,Testing and Commissioning of analog addressable type Manual pull station at indicated locations with necessary termination as per acceptable specifications and full ready for operation. | 14 | each | |
| 256 | 8.66 | od306014/2019_2020 : Supply, installation, testing and commissioning of Analogue Addressable type Optical Smoke Detector (photoelectric type) complete with all accessories like base. base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. (below false ceilng). UL 286 (7th edition approved) and FM approved. | 503 | each | |
| 257 | 8.67 | od306017/2019_2020 : Supply,Installation,Testing & Commissioning of Analogue Addressable Response indicator including all accessories compatible with all the fire detectors required for complete installation. | 185 | each | |
| 258 | 8.68 | od306020/2019_2020 : Supply,Installation,Testing and Commissioning of Short Circuit Isolator Module for isolating the affected segment of the circuit, allowing the remaining devices to continue operation. | 30 | each | |
| 259 | 8.69 | od306021/2019_2020 : Supply, Installation,Testing and Commissioning of addressable control module for hooters,for AHU & stairs pressurization Fan, Access control integration etc. at different locations complete with all fixing accessories. | 42 | each | |
| 260 | 8.7 | od306096/2019_2020 : Supply,Installation,Testing and Commissioning of Intelligent Addressable monitor modules for Sprinkler Flow Switch, Fire doors, magnetic contacts & WLD monitoring complete as required as per specifications | 17 | each | |
| 261 | 8.71 | od308324/2019_2020 : Supply, laying, testing and commisioning and making terminations for 2 Core x 1.5 Sq.mm cable, Armoured Screened FRLS Twin Twisted PVC Insulated copper cable along with all accessories required for complete installation, making terminations etc where required | 4098 | metre | |
| 262 | 8.72 | FIRE EXTINGUISHERS | |||
| 263 | 8.73 | od306480/2019_2020 : Supply and fixing of 4.5 Kg CO2 (Wheel) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 18 | each | |
| 264 | 8.74 | od306481/2019_2020 : Supply and fixing of 2Kg CO2 (Wheel) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 1 | each | |
| 265 | 8.75 | od306501/2019_2020 : Supply and fixing of 2 Kg Fire Extinguisher Clean Agent HFC 236 FA, Stored Pressure Type, Pressure Gauge, Ozone Depletion Potential Zero, Gross Weight 3.7 Kg, Empty Weight 1.7 Kg, Can Height 344MM, Diameter 108 MM, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2 Meters IS 15683 | 9 | each | |
| 266 | 8.76 | od306549/2019_2020 : Supply and fixing of 2kg class K (wet chemical) Type Fire Extinguisher storred pressure , Design, construction and testing as per IS 15683 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 2 | each | |
| 267 | 8.77 | od306550/2019_2020 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 4 nos of fire buckes, or , duly painted over a coat of primer. | 2 | each | |
| 268 | 8.78 | od307938/2019_2020 : Supply and fixing of 2Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 59 | each | |
| 269 | 8.79 | od307939/2019_2020 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 15 | each | |
| 270 | 8.8 | od307940/2019_2020 : Supply and fixing of 9Kg Mechanical foam Type Fire Extinguisher storred pressure, Design, construction and testing as per IS 15683 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 1 | each | |
| 271 | 8.81 | Two Way Talk Back & Public Address system | |||
| 272 | 8.82 | od308085/2019_2020 : Supply,installation,testing&commisioning of automatic 16 ZONE master control console to connect 16 nos of PA Talk back unit microprocessbased complete with floor to floor announcing and talkback facilities with the following features and made functional:(a)Feather type keypads to select the zones. (b)Moulded plastic attractive enclosure. (c)Back light Liquid Crystal Display (LCD) (d) User friendly interactive display.(e)Announcement selector PTTSwitch. (f)Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire Control Room. | 1 | each | |
| 273 | 8.83 | od299800/2020_2021 : Supply, Installation, Testing & Commissioning of Analogue Addressable Fire<br>Alarm Panel with 4 loop expandable upto 8 loop including battery backup. The<br>panel shall be microprocessor based with its own micro controller, memory,<br>communication module and fire device loop.Each Loop capable of connecting 99<br>detectors and 99 modules 99 devices. The panel shall have 2x12v/12 Ah SMF<br>Battery (or more), Keypad operation, L C D unit to indicate Fire / Fault Signal of<br>individual unit, complete in all respects. operation of speakers. The Panel shall<br>have :Loop connected devices include detectors, call-points, loop isolators,<br>Hooter. Panel shall work in degrade mode in case of CPU failure. Panel should be UL 864 and FM approved | 1 | each | |
| 274 | 8.84 | od308106/2019_2020 : Controller Unit Goose neck type microphone and with the following features: (i) Built in Power supply.( ii) Zone Selector switching Circuit (iii) Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional .Panel to be installed in the Fire Control Room. | 1 | each | |
| 275 | 8.85 | od308113/2019_2020 : Supply,installation,testing and commisioning of Public Address speaker with talk back facility 6 Watts with LMT and call switch, made out of powder coated CRC A sheet ,wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting. | 14 | each | |
| 276 | 8.86 | od308312/2019_2020 : Supply,Installation,Testing and Commissioning of 4 core x 1 sq.mm copper wires PVC sheathed with ISI mark. | 2100 | metre | |
| 277 | 8.87 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 700 | metre | |
| 278 | 8.88 | Signages | |||
| 279 | 8.89 | od307057/2019_2020 : Providing and installation in position self glowing "FIREEXIT" / "EXIT" signboard swith directional arrow markings of made of luminescent safety ,rigid sheet in green colour,photoluminescent type Samples has to be approved by the Architect before procuring the same. | 72 | each | |
| 280 | 8.9 | od307058/2019_2020 : Providing and installation in position self glowing Signage with printed FIRE EXTINGUISHER /FIREHYDRANT /FIREFIGHTING EQUIPMENTST OREDINSIDE, of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts. | 24 | each | |
| 281 | 8.91 | od307059/2019_2020 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Signage with printed IN CASE OF FIRE DO NOT USE LIFT,USE THE STAIRS,of 1.25 cm height letters in red with white background. The board shall be fixed at the height of 2 mts. from finished floor near lifts. | 17 | each | |
| 282 | 8.92 | od307320/2019_2020 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building. | 2 | each | |
| 283 | 8.93 | od307321/2019_2020 : Supply and installation of in position the signages "FIREORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinylepainted foamboard of 3'x4'. Samples has to approved by the Architect before procuring the same.A) ALERT THE SECURITY BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY, AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE FIRE EXTINGUISHER OR WATER FROM NEAREST HOSE REEL. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION ,LAY FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. F) TRY TO COVER YOUR FACE WITH A WET TOWEL TO AVOID BREATHING SMOKE OR OTHER TOXIC FUMES. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANYONE OF THE FOLLOWING PHONE NUMBERS:101 /………………….( Local fire station number) C) REFER EVACUATION PLAN.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF CASUALTIES, CALL AMBULANCE (Local numbers:) PHONE : ----------------------- | 1 | each | |
| 284 | 8.94 | od307322/2019_2020 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Floor indentification signages (ie,GROUNDFLOOR,FIRSTFLOOR,…etc.) at each stair enclosure on every floor,indicating the floor number in words,lettering size shall be7.5cm with contrasting colour from background. | 28 | each | |
| 285 | 8.95 | od307698/2019_2020 : Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional.<br> | 17 | each | |
| 286 | 8.96 | od307699/2019_2020 : Supply and installation in position self glowing Signage with printed IN CASE OF FIRE BREAK GLASS, of 1.25cm height letters in red with white background.The size of the board shall be 10x15 cm and shall be fixed at the height of 2 mts. from finished floor near the Manual Call Points. | 14 | each | |
| 287 | 8.97 | Fire shaft doors | |||
| 288 | 8.98 | od308227/2019_2020 : Providing and fixing of Sheet metal duct door for the fire duct size 1500 X900mm ,fabricated from 16SWG GI CR Sheet & 18SWG shutter, sheets fully powder coated as per standard colour requirements of the Client with door handle, hinges and locking arrangements. | 13 | each | |
| 289 | 9 | Elevator | |||
| 290 | 9.01 | od317090/2019_2020 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift; with machine room;serving 6 stops / 6 openings rise 21.5 m; 2.2m x 3m depth hoistway required. 1.6m depth pit, 4.3m overhead, 1.3m x 2.4m x 2.4m car size, stainless steel hairline finish 20mm recesss for flooring type car enclosure, Centre opening doors in SS hairline, 1.2m x 2.2m entrance size, Automatic with ACVVVF system door opening, Electronic door detector for door protection,One no. car operating panel provided with micro action buttons (Positioned at right side of front return panels), Direction and position indicator with LCD display. Fireman service, Alarm button, Overload warning , Intercommunication system, Attender operation, voice synthesizer, Emergency Fireman operation, Automatic rescue device, Independent operation, All fixture face plates in stainless steel hairline finish | 5 | no | |
| 291 | 10 | RO PLANT | |||
| 292 | 10.01 | od316671/2019_2020 : Supply, testing & commissioning of 1000 LPH R.O plant, with all accessories like Pressure Gauge, pressure switch for Low & High flow, Flow Indicators, conductivity meters, SS Pressure tubes to house Membranes, High pressure Pump, Water Panel- SS Panel to house Pressure Gauge & Rota Meters Electrical Control Panel, Water Panel, Micron Filter & Antiscalents dosing pum,Auto Flushing Unit, Electrical Control Panel with contactor for pumps, power on & trip indicators etc on EX Kerala basis. Commissioning charges included. The cost shall include all required Piping in Sch 40 UPVC ASTM, Valving with compatible materials and necessary measurements for pressure and flow. | 2 | set | |
| 293 | 10.02 | od316673/2019_2020 : Supply,Installation,Testing and Commissioning of SS304 Collection tank of 5000 Liters having 1.5 mm Shell Thickness, with all necessary piping interconnections as required. | 2 | set | |
| 294 | 10.03 | od316675/2019_2020 : Supply,Installation,Testing and Commissioning of Pyrogen Filters of 0.1-0.3 mm poresizeatinlet & outlet of the high pressure pump with all necessary piping interconnections as required. | 2 | set | |
| 295 | 10.04 | od316676/2019_2020 : Supply, Installation, Testing and Commissioning of Recirculation pump for the feeding water to dialysis unit and CSSD etc. including all required suction and delivery piping & valving, pressure guages etc completeMoC of the pump shall be Stainless steel, Configuration 1W+1S.<br>Flow rate = 2000 Litres/Hr<br>Head: 30 m<br>br>Power :1 HP | 1 | set | |
| 296 | 10.05 | od316677/2019_2020 : Supply, Installation, Testing and Commissioning of UV System for elimination of bacterial contamination, the MoC of the pipes shall be SS and the UV will have Min: 40 w power with all necessary piping interconnections as required. | 1 | set | |
| 297 | 11 | BIOGAS PLANT | |||
| 298 | 11.01 | od309002/2019_2020 : Supply, installation, testing and commissioning of 30 cum bio gas plant with a waste treatment capacity of<br>250 kg/day. The rate shall be inclusive of all safety devices and accessories required for complete<br>installation as required.<br> | 1 | no | |
| 299 | 12 | STP CIVIL WORK | |||
| 300 | 12.01 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 960.246 | cum | |
| 301 | 12.02 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 749.969 | cum | |
| 302 | 12.03 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 19.143 | cum | |
| 303 | 12.04 | 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level | 175.93 | cum | |
| 304 | 12.05 | 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). | 175.93 | cum | |
| 305 | 12.06 | od258175/2020_2021 : Providing circular concrete rings | 18 | no | |
| 306 | 12.07 | od258177/2020_2021 : Providing fillings in Soak pit<br> | 2 | no | |
| 307 | 12.08 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 42.055 | sqm | |
| 308 | 12.09 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 907.685 | sqm | |
| 309 | 12.1 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 233.511 | sqm | |
| 310 | 12.11 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 20347 | kilogram | |
| 311 | 12.12 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | 1116.96 | sqm | |
| 312 | 12.13 | 22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) | 1296.96 | sqm | |
| 313 | 12.14 | 13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster | 209.28 | sqm | |
| 314 | 12.15 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 210.986 | cum | |
| 315 | 12.16 | 190KLD STP(MBBR)MECHANISM PART | |||
| 316 | 12.17 | od313982/2019_2020 : Supply, Installation, Testing & Commissioning of Coarse Screen for sewage-MoC: SS 304, Angle of Inclination – 45 deg, Frame in 1” Square Pipe and Bars made of 10 mm Square Pipe with 12 mm Spacing with suitable facility to remove trapped materials. | 1 | each | |
| 317 | 12.18 | od314355/2019_2020 : Supply, Installation, Testing & Commissioning of Coarse Screen for sewage-MoC: SS 304, Angle of Inclination – 45 deg, Frame in 1” Square Pipe and Bars made of 10 mm Square Pipe with 12 mm Spacing with suitable facility to remove trapped materials. | 1 | no | |
| 318 | 12.19 | od314401/2019_2020 : Supply, Installation, Testing & Commissioning of Raw Sewage & Sullage transfer pump-Submersible Sewage Transfer & Sullage Transfer Pumps (cutter pump), Continuous Duty, Minimum Discharge of 200 LPM, or above, with 10 m Head, three phase with Power: 2.0 HP,in a configuration of 1 Working & 1 Standby, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete | 2 | set | |
| 319 | 12.2 | od314407/2019_2020 : Supply, Installation, Testing & Commissioning of Aeration Grid with Coarse Bubble DiffusersDisc or Tube Type Coarse Bubble Diffusers with Design Flow rate of 10 m3/hr with EPDM membrane construction, 24 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required in Collection tanks, Equalization tank, Chemical precipitation tank etc. | 20 | set | |
| 320 | 12.21 | od314434/2019_2020 : Supply, Installation, Testing & Commissioning of Aeration Grid with Fine Bubble Diffusers in MBBR tank.Disc or Tube Type Fine Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 16 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required for achieving uniform aeration. | 8 | set | |
| 321 | 12.22 | od314450/2019_2020 : Supply, Providing in Position, Testing & Commissioning of tube settler media in secondary settling tank.<br>Minimum Specific (1.1mm thick PVC of unequal hexagonal chevron shape)<br><br> | 2 | cum | |
| 322 | 12.23 | od314472/2019_2020 : Supply, Installation, Testing &Commissioning of Twin Lobe Blower with Motor.Continuous Duty, Operating Discharge of 300 m3/hr or above, with differential Pressure of 4 m WC, With three phase Motors with Power: 10 HP, pulley fixed on a frame with Inlet / Outlet Silencers and Header Piping as required in MSEP, in a configuration of 1 Working & 1 Standby, also with Outlet Pressure monitoring, Pressure Relief Valves, Check Valves, Hand Valves & all required accessories etc. Complete. | 14 | set | |
| 323 | 12.24 | od314480/2019_2020 : Supply, Providing in Position, Testing & Commissioning of Aerobic Bio media for MBBR TankMinimum Specific Surface Area of 500 m2/m3, Voidage - 95%, MoC: Virgin PE (Preferably Imported), Type - Cylindrical,Size: 25mm X 12mm | 6 | cum | |
| 324 | 12.25 | od314560/2019_2020 : Supply, Providing in Position, Testing & Commissioning of Aerobic Bio media for MBBR TankMinimum Specific Surface Area of 500 m2/m3, Voidage - 95%, MoC: Virgin PE (Preferably Imported), Type - Cylindrical,Size: 25mm X 12mm | 2 | cum | |
| 325 | 12.26 | od314562/2019_2020 : Supply, Installation, Testing & Commissioning of Electronic metering pumps.Diaphragm Type Electronic Dosing Pump, MoC: PP, Foot Valve, Suction/Discharge LDPE Tubing, Strokes: Manually Regulated, Pressure: 0.0-3.5 kg/cm2, PE Storage Tank - 100 L and all accessories complete. | 1 | set | |
| 326 | 12.27 | od314618/2019_2020 : Supply, Installation, Testing & Commissioning of Sludge Transfer Pump & Sludge re-circulation pump.Non Clog Self Priming Type with back pull out design, MoC: CI, Packing - Non asbestos PTFE gland, Capacity 10 m3/Hr, Head - 10 m, Power- 1.0 HP, in a configuration of 1 Working each with No Standby | 2 | set | |
| 327 | 12.28 | od314628/2019_2020 : Supply, Installation, Testing & Commissioning of Filter Feed Pumps.MoC: Cast Iron, Duty: Continuous, Packing: Mechanical Seal, with a Flow Rate of min 300 LPM or above at a Head >25 m In a configuration of 1 Working & 1 Standby, Power- 5 HP, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete | 1 | set | |
| 328 | 12.29 | od314694/2019_2020 : Supply, Installation, Testing & Commissioning of Pressure Sand Filter.Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Sand & Pebbles, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete | 1 | set | |
| 329 | 12.3 | od314698/2019_2020 : Supply, Installation, Testing & Commissioning of Activated Carbon Filter.Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Activated Carbon – IV 900, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete | 1 | set | |
| 330 | 12.31 | od314700/2019_2020 : Supply, Installation, Testing & Commissioning of Electrical control panel: Manual operation.All Switch gear- MCB, OLR, Single Phase Preventer, H/L Protection, Volt meter, Push Button, Indication Lamp ,TOD energy meter, flow meter etc of approved Make for Level based On-off Control Valves provided with float switch etc. | 1 | set | |
| 331 | 12.32 | od314710/2019_2020 : Supply, Installation, Testing & Commissioning of Electrical Cables considering a plant room with in 5 m nearby STP.Cables of approved make 4Core 10 mm2, Aluminium Armored Cable, 2.5 mm2- Flexible Cu Cable, 1.5 mm2-Cu CableFlexible | 1 | set | |
| 332 | 12.33 | od314782/2019_2020 : Supply, Installation, Testing & Commissioning of plumbing interconnections considering a plant room with in 5 m nearby STP.Airline Header: GI/MS, Air line after header UPVC-ASTM, Pressurized Water & Wastewater lines - UPVC-ASTM, Overflow Conduits / Gravity Lines – PVC 10 kg/cm2, Ball Valves - UPVC, Gate & Globe Valves – Brass,Slotted Chanel & Rod – GI | 1 | set | |
| 333 | 12.34 | od128615/2020_2021 : Supplying and fixing C.I cover with frame for manholes: 500mm dia C.I cover<br>(medium duty ) the weight of the cover to be no less than 58 kg | 22 | set | |
| 334 | 12.35 | Plant room Details | |||
| 335 | 12.36 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 17.27 | cum | |
| 336 | 12.37 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 5.36 | cum | |
| 337 | 12.38 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | 7.074 | cum | |
| 338 | 12.39 | 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level | 8.599 | cum | |
| 339 | 12.4 | 5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). | 8.599 | cum | |
| 340 | 12.41 | 50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | 7.44 | cum | |
| 341 | 12.42 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 199.98 | sqm | |
| 342 | 12.43 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 202.761 | sqm | |
| 343 | 12.44 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 83.169 | kilogram | |
| 344 | 12.45 | 9.57.3 : Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete.75x47x1.70 mm | 3 | no | |
| 345 | 12.46 | 9.63.3 : Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:150x10 mm | 2 | no | |
| 346 | 12.47 | 9.64 : Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete. | 1 | no | |
| 347 | 12.48 | 9.66.3 : Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:75 mm | 2 | no | |
| 348 | 12.49 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 4.2 | sqm | |
| 349 | 13 | WATER TREATMENT PLANT | |||
| 350 | 13.01 | od315404/2019_2020 : Supplying, installing, testing and commissioning approved make Filter Feed pump for feeding water to the Filtration Plant including all required suction and delivery piping & valving, pressure guages etc complete. MoC of the pump shall be CI, Configuration 1W+1S.<br>Flow rate = 15000 Litres/Hr<br>Head: 30 m<br>Make : Wilo / Grundfos / Equivalent<br>Power :5 HP (VTC) | 1 | set | |
| 351 | 13.02 | od315405/2019_2020 : Supplying, installing, testing and commissioning approved make Raw Water Iron Removal filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of underbed & multi -grade filter media to suit the requirement etc. complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>Make : Pentair/Aquanomics/Advanced Composites | 1 | set | |
| 352 | 13.03 | od315406/2019_2020 : Supplying, installing, testing and commissioning approved make Raw Water Pressure sand filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of under bed & multi -grade filter media to suit the requirement etc. complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>Make : Pentair/Aquanomics/Advanced Composites | 1 | set | |
| 353 | 13.04 | od315420/2019_2020 : Supplying, installing, testing and commissioning approved make Raw Water Activated carbon filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of underbed & multi -grade filter media to suit the requirement etc complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>Media: Activated Carbon: 1100 IV<br>Make : Pentair/Aquanomics/Advanced Composites | 1 | set | |
| 354 | 13.05 | od315429/2019_2020 : Supplying, installing, testing and commissioning approved make Electronic dosing system for dosing Chlorine into the Treated water with pre - set dosage based on the quantity of water. The Dosing system shall consist of Electronic dosing Pump with positive displacement type with adjustable stroke length and frequency. The quoted rate shall also include FRP/HDPE chemical solution tank, necessary electricals etc., complete to make the operation automatic.<br>Capacity - 6 to 12 LPH<br>Maximum head: 4 Bar<br>Power : VTC<br>MoC of wet parts: PP<br>Chemical Tank Capacity: 50 L | 1 | set | |
| 355 | 13.06 | od315433/2019_2020 : Supplying, installing, testing and commissioning Electrical Control Panel Suitable for Auto/Manual operation. The panel shall have Switch gear, MCB, OLR, Single Phase Preventer, H/L Protection, Push Button, Indication Lamp etc. of approved make. | 1 | set | |
| 356 | 13.07 | od315473/2019_2020 : Supplying, installing, testing and commissioning approved make Treated Water Transfer Pump including all required suction and delivery piping & valving, pressure guages etc complete. MoC of the pump shall be CI, Configuration 1W+1S<br>Flow rate = 15000 Litres/Hr<br>Head: 25 m<br>Make : Wilo / Grundfos / Equivalent<br>Power :3 HP | 1 | set | |
| 357 | 13.08 | od316570/2019_2020 : Providing PCC foundations for plant room | 8 | cum | |
| 358 | 13.09 | od316571/2019_2020 : Providing Solid Block masonry with precast solid blocks with a mix of 1:6 | 10 | cum | |
| 359 | 13.1 | od316572/2019_2020 : Providing Plastering works | 144 | cum | |
| 360 | 13.11 | od316578/2019_2020 : Providing and fixing structural roofing using precoated galvanized iron profile sheet, 5-7 microns Epoxy coating,including fixing complete. The frames of the roof shall be GI Pipes | 80 | sqm | |
| 361 | 13.12 | od316579/2019_2020 : Providing Grill lof required patern and with window frames using MS flat/Square bars. The cost shall be inclusive of Eproxy anti corrosive paint | 15 | sqm | |
| 362 | 13.13 | od316581/2019_2020 : Finishing of PCC floor with self level epoxy coating | 45 | sqm | |
| 363 | 14 | OPERATION THEATRE | |||
| 364 | 14.01 | od312363/2019_2020 : "Providing supply and installation of storage unit - ( 1700 x 900 x 350 ) made of 1.5 mm thick SS Sheet with sterile surface coating ,complete with all accessories.<br>"<br> | 4 | no | |
| 365 | 14.02 | od312364/2019_2020 : Double dome surgical light unit incorporating the latest Led technology only for homogenous and shadow less operating light field with single coour LEDs with life time of ≥ 48000hrs<br> | 4 | no | |
| 366 | 14.03 | od312366/2019_2020 : Providing, fixing, supply and installation of dirty hatch box made out of SS 304 for dispoasl of dirty linen /waste.Each Hatch will be equipped with two doors and the door will be operated electronically .The Hatch will be designed in such a way that only one door will be opened at one time.The UV light wiil be so installed that it is kept on while both the doors are closed ,this UV light has to be automatically turned off in case of opening of either of the doors. There shall be indicators on both sides of the OT so that door open/close status can be monitored from both ends.<br> | 4 | no | |
| 367 | 14.04 | od312367/2019_2020 : 2 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish having front acess panel with following features : --Hands free Operation with Infrared sensor - Thermostatic Mixing Valve control located behind the access panel & maintaining constant water temperature -User defined settings of 1 to 3 min -Provided with infrared sensor & thermostatic control. <br> | 4 | no | |
| 368 | 14.05 | od312368/2019_2020 : Single Arm Pendant ( Anaesthesia) - Indigenous with 1000 mm long arm with Horizontal movements having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 5/15 Amp, and gas outlets. <br> | 4 | no | |
| 369 | 14.06 | od312369/2019_2020 : Providing, fixing , Supply & Installation of Single Arm Pendant ( Surgeon) - Indigenous with 1000 mm long arm with Horizontal movements having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 5/15 Amp, and gas outlets. <br> | 4 | no | |
| 370 | 14.07 | od312370/2019_2020 : Providing, Fixing, Supply and Installation of Operating Writing List Board of size ( 948mm x 648mm )<br> | 4 | no | |
| 371 | 14.08 | od312371/2019_2020 : Providing, Fixing, Supply and Installation of seamless Lead mat static conductive flooring system , 2 mm thick ,with perfectly curved flash covings,all joints welded as per the colour and pattern approved by hospital.<br> | 180 | no | |
| 372 | 14.09 | od312372/2019_2020 : Providing, Fixing, Supply and Installation and Commissioning of Pressure Relief Dampers with Backside Grills (SS ) - Indigenous having multi 304 graded stainless steel blades for maintaining the positive pressure inside the operation theatre <br> | 4 | no | |
| 373 | 14.1 | od312373/2019_2020 : Providing, Fixing, Supply, Installation, testing and Commissioning of Surgeon Control Panel ( Touch Screen ) - Indigenous .Membrane type Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall alongwith Distribution Board comprising of the following : -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Control <br> | 4 | no | |
| 374 | 14.11 | od312374/2019_2020 : Providing, Fixing, Supply & installation of UV LIGHTS | 12 | no | |
| 375 | 14.12 | od312376/2019_2020 : Supply , installation, Testing and Commissioning of Complete Plenum System with Hepafilters-IndigenousAir Supply (1900 mm X 1900 mm) ceiling for air distribution system complete with 6 Nos. HEPA Filters ( efficiency 99.97% down to 0.3 microns ) complete.For Distribution of supply/ return air flow as follow. a) 30% of return air exhausted through blower near the AHU. b). 30% Fresh air will be mixed in mixing chamber.c). 70% cooling air will be circulating from AHU. <br> | 4 | no | |
| 376 | 14.13 | od312377/2019_2020 : Providing, Fixing, Supply, Installation, and Commissioning of Hermetically Sealing Sliding Doors ( Automatic ) , having high pressure laminate on both sides that could withstand high abrasion , vision panels (300x300mm) , for smooth sliding .The door moves on nylon wheels within an single piece aluminium extruded track. Size is (1500 x 2100 ) <br> | 4 | no | |
| 377 | 14.14 | od312526/2019_2020 : Providing, Fixing, Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen (948mm x 648mm) designed to provide a high level of control luminance without flicker. (Dimming Range 3-100%) <br> | 4 | no | |
| 378 | 14.15 | od312527/2019_2020 : "Providing, Fixing, Supply & installation of Prefabricated Modular Opearting Room using PUFF PANEL with Anti Bacterial & Anti Fungal Paint 304 grade stainless steel panel sandwitch has been injected under high pressure, with a minium density of 40kg/m3. & Antifungal paint ,wall glaze or equivalent to a minimum dry film thickness of 300 microns having overlap floor covering ,ceiling system and door frames by 25mm to provide a continous sealed surface ( for wall & ceiling )<br>"<br> | 375 | sqm | |
| 379 | 15 | CCTV SYSTEM | |||
| 380 | 15.01 | od306265/2019_2020 : Supply, Installation,testing and commissioning of 3.6 mm fixed lens ,2MP , IR Dome camera 1.0 lux, 120 db WDR POE and vandal proof with all connectors and necessary accessories for mounting in True/false ceiling | 12 | no | |
| 381 | 15.02 | od306266/2019_2020 : Supply, Installation,testing and commissioning of Varifocal Dome Camera with 2 MP 0lx, built-in IR LED,120DB WDR , 2.8-12 mm POE,Vandal proof with all connectors and necessary accessories for mounting on true/false ceiling <br> | 31 | no | |
| 382 | 15.03 | od306182/2019_2020 : Supply, Installation,testing and commissioning of Indoor Varifocal Bullet Camera with 2 MP , built-in IR LED, , 2.8-12 mm POE , IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling<br> | 6 | no | |
| 383 | 15.04 | od306183/2019_2020 : Supply, Installation,testing and commissioning of Outdoor type Varifocal Bullet Camera with 2 MP 0lx, built-in IR LED,DWDR , 2.8-12 mm POE ,IP 67 ,Vandal proof with all connectors and necessary mounting accessories for external areas. <br> | 12 | no | |
| 384 | 15.05 | od306185/2019_2020 : Supply, installation, testing and commissioning of 32 Channel Network Video Recorder Supports 32 channels 1080p resolution video recording at real time, NVR ONVIF , Recording resolution of Max 5MP, Minimum of 200Mbps of recording, should support dual video output,H265+, H.265,H.264, MJPEG Compression.video playback / relay at real time. <br> | 2 | no | |
| 385 | 15.06 | od306187/2019_2020 : Supply, installation, testing and commissioning of HDD for cameras recording at 1080p @ 10fps for 30 days 24 hours - 6 TB | 4 | no | |
| 386 | 15.07 | od306267/2019_2020 : Supply, installation, testing and commissioning of workstation with Intel I7 or above, 8 GB ram and 2 TB HDD. <br> | 1 | no | |
| 387 | 15.08 | od306268/2019_2020 : Supply, Installation, Testing and Commissioning of LED Monitor 40" with all required accessories<br> | 2 | no | |
| 388 | 15.09 | PA SYSTEM | |||
| 389 | 15.1 | od306269/2019_2020 : Supply & Installation of Wall mount 6/9/12W Speaker for PA system<br> | 34 | no | |
| 390 | 15.11 | od306270/2019_2020 : Supply & Installation of ceiling mount 6W Speaker for PA system<br> | 80 | no | |
| 391 | 15.12 | od306271/2019_2020 : Supplying, installing, testing and commissioning Audio booster Amplifier 240 Watts RMS, complete with Speaker wires and RGB connectors for Integrated Music & PA system<br> | 1 | no | |
| 392 | 15.13 | od306272/2019_2020 : Supplying, installing, testing and commissioning Audio booster Amplifier 480 Watts RMS, complete with Speaker wires and RGB connectors for Integrated Music & PA system<br> | 2 | no | |
| 393 | 15.14 | od306273/2019_2020 : Supply & Installation of Master Controler for managing and controlling upto 6 zone should be able to integrated with FAS.<br> | 1 | no | |
| 394 | 15.15 | od306274/2019_2020 : Supply & Installation of 6 zone call station with mic<br> | 1 | no | |
| 395 | 15.16 | od306275/2019_2020 : Supply, installation, testing & commissioning of Audio player with DVD/USB/FM connectivity option for playing music<br> | 1 | no | |
| 396 | 15.17 | od306276/2019_2020 : Supply & Wiring of Speaker system using 2core of 1.5sqmm PVC insulated copper FRLS unarmoured cable<br> | 2160 | metre | |
| 397 | 15.18 | od127313/2020_2021 : Supply & installation of computer | 51 | no | |
| 398 | 15.19 | od127314/2020_2021 : Supply & installation of printer cum scanner | 28 | no | |
| 399 | 15.2 | od127315/2020_2021 : Supply & installation of 32 inch LED TV | 8 | no | |
| 400 | 15.21 | ACCESS CONTROL SYSTEM | |||
| 401 | 15.22 | od306277/2019_2020 : Supply, Installation, Testing and Commissioning of Two Reader Controller with the necessary Power Supply Unit<br> | 9 | no | |
| 402 | 15.23 | od306278/2019_2020 : Supply, Installation, Testing and Commissioning of Card reader siutable for IP connectivity with integrated to main access system.<br> | 13 | no | |
| 403 | 15.24 | od306279/2019_2020 : Supply, Installation, Testing and Commissioning of Biometric reader with inbuilt proximity reader for Time and attendance, in /out time recording siutable for IP connectivity<br> | 2 | no | |
| 404 | 15.25 | od306280/2019_2020 : Supply, Installation, Testing and Commissioning of Proximity Cards <br> | 500 | no | |
| 405 | 15.26 | od306281/2019_2020 : Supply, Installation, Testing and Commissioning of Exit push button<br> | 13 | no | |
| 406 | 15.27 | od306282/2019_2020 : Supply, Installation, Testing and Commissioning of Single Leaf Electro Magentic Lock with Magnetic Contact<br> | 10 | no | |
| 407 | 15.28 | od306283/2019_2020 : Supply, Installation, Testing and Commissioning of Double Leaf Electro Magentic Lock with Magnetic Contact<br> | 3 | no | |
| 408 | 15.29 | od306284/2019_2020 : Supply, Installation, Testing and Commissioning of licensed security management software with Time Attendance and Access including programming of access cards. <br> | 1 | no | |
| 409 | 15.3 | od306285/2019_2020 : Supply, installation, testing and commissioning of workstation with Intel I7 or above, 8 GB ram and 2 TB HDD. Same system will be used for Access control<br> | 1 | no | |
| 410 | 15.31 | od306286/2019_2020 : Supply and Surface laying of 4 CoreX 0.75 Sq.mm unarmoured FRLS PVC Insulated Cable - for controller to Electromagnetic lock<br> | 175 | metre | |
| 411 | 15.32 | od306287/2019_2020 : Supply and Surface laying of 8 CoreX 0.75 Sq.mm unarmoured FRLS PVC Insulated Cable - Reader to Controller <br> | 175 | metre | |
| 412 | 15.33 | od306288/2019_2020 : Supply and Surface laying of 2 CoreX 1.0 Sq.mm unarmoured shielded FRLS PVC Insulated Cable - controller to exit switch<br> | 175 | metre | |
| 413 | 15.34 | PASSIVE | |||
| 414 | 15.35 | 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable | 5707 | metre | |
| 415 | 15.36 | od306416/2019_2020 : Supply, Installation, Testing and Commissioning of 24 Port Cat6 Patch Panel with all accaessories loaded <br> | 11 | no | |
| 416 | 15.37 | od306417/2019_2020 : Supply, fixing, testing and commissioning of Cable Manager<br> | 13 | no | |
| 417 | 15.38 | od306419/2019_2020 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter as required for complete installation.<br> | 79 | no | |
| 418 | 15.39 | od306421/2019_2020 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter as required for complete installation.<br> | 149 | no | |
| 419 | 15.4 | od306428/2019_2020 : Supply, fixing, testing and commissioning of CAT6 Information Outlets for Data with faceplate, Keystone Jack etc. as required for complete installation.<br> | 93 | no | |
| 420 | 15.41 | od306429/2019_2020 : Supply, fixing, testing and commissioning of Keystone jack for data outlets (for Camera & Wifi Access points) as required installation.<br> | 69 | no | |
| 421 | 15.42 | od306431/2019_2020 : 19", 9U 500 MM wide x 550 MM Depth Wall Mount Networking Rack with Front Glass Door, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Horizontal PDU 6X5Amps - 1 No, Cooling Fan - 2 Nos, Hardware Screws and all other required accessories<br> | 4 | no | |
| 422 | 15.43 | od306438/2019_2020 : 19", 22U 600 M M Wide X 800 M M Depth Floor M ount Networking Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, M ounting Hardware Screwsand all other required accessories<br> | 1 | no | |
| 423 | 15.44 | od306444/2019_2020 : 19", 42U 800 MM Wide X 1000 MM Depth Floor Mount Server Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, M ounting Hardware Screwsand all other required accessories<br> | 1 | no | |
| 424 | 15.45 | SWITCHES | |||
| 425 | 15.46 | od306457/2019_2020 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T Network switch with 24 port PoE 1G copper uplink and all related termination accessories as per vendor specific System requirement. 24 Port PoE Switch <br> | 6 | no | |
| 426 | 15.47 | od307648/2019_2020 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T Manegable L3 Core Switch with 10G fibre uplink 24x 1G copper ports and all related termination accessories as per vendor specific System requirement. 24 Port Switch <br> | 1 | no | |
| 427 | 15.48 | od306461/2019_2020 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T network Switch with 1G copper uplink 24x 1G ports and all related termination accessories as per vendor specific System requirement. 24 Port Switch <br> | 5 | no | |
| 428 | 15.49 | EPBAX | |||
| 429 | 15.5 | od306463/2019_2020 : "Supply, Installation, Testing and Commissioning of ""PBX with 70 Analog extensions expandable up to 120 ports (Extensions/Trunks) , 5 Digital IP Extensions and 2 SIP Licensewith maximum of 20 concurrent calls Network Interface: 1×10/100M LAN port 1 PRI interface, RAM: DDR3 1GB, Power Consumption: 12V/0.8A, 9.6W Maximum, Failover Function (optional), Web Interface, Call Dashboard, DISA, IVR, Call Hunt, 19'' rack mountable etc. Features:Room monitoring from outside<br>Warning Message during night mode<br>Remote Inspection, with auto-emergency call<br>Sensor Connectivity with auto-emergency call and warning message sending<br>Built-In Auto Answer<br>(Standby mode) during night mode<br>Voice Mail Integration<br>Paging Announcement<br>Programmable Function Keys""<br>"<br> | 1 | no | |
| 430 | 15.51 | od306465/2019_2020 : Supply, installation, testing and commissioning of single line Digital master console phone with 5 navigation keys with necessary connection as required for complete installation.<br> | 1 | no | |
| 431 | 15.52 | od306494/2019_2020 : Supply, installation, testing and commissioning of Digital phone with necessary connection as required for complete installation as directed by the engineer in charge.<br> | 3 | no | |
| 432 | 15.53 | od306503/2019_2020 : Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge.<br> | 74 | no | |
| 433 | 15.54 | od306505/2019_2020 : Supply and fixing 150 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br> | 1 | no | |
| 434 | 15.55 | od306514/2019_2020 : Supply and fixing 20 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br> | 4 | no | |
| 435 | 15.56 | od306516/2019_2020 : Supply and fixing 10 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br> | 1 | no | |
| 436 | 15.57 | od306544/2019_2020 : Supply and laying 20 pair telephone cable<br> | 50 | metre | |
| 437 | 15.58 | od306551/2019_2020 : Supply and laying 10 pair telephone cable<br> | 15 | metre | |
| 438 | 15.59 | 1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair | 2930 | metre | |
| 439 | 15.6 | od306750/2019_2020 : Supply and installation of modular type telephone socket outlet mounted in seperate PVC box including supply of modular PVC mounting box, telephone socket covering with modular coverplate giving connection etc as required. <br> | 74 | no | |
| 440 | 15.61 | WIFI | |||
| 441 | 15.62 | od306791/2019_2020 : Supply, Installation, Testing and Commissioning of Wifi Access Point with Dual Band 8011.ABGN/AC 1200 Mbps Speed<br> | 8 | no | |
| 442 | 15.63 | od306798/2019_2020 : Supply, Installation, Testing and Commissioning of Wifi Controller with licence for minimum 25 Wifi Access points to manage the bandwidth, privilege, password etc<br> | 1 | no | |
| 443 | 15.64 | PROJECTOR | |||
| 444 | 15.65 | od307055/2019_2020 : Supply, Installation, Testing & Commissioning of 3300 Lumen Short through Projector WXGA with HDMI, VGA out,USB connectivity<br> | 2 | no | |
| 445 | 15.66 | od307073/2019_2020 : Supply, Installation, Testing & Commissioning of 120" diagonal, Wall mountable, Projection screen<br> | 2 | no | |
| 446 | 15.67 | od307080/2019_2020 : Supply, Installation, Testing & Commissioning of High Performance dual speaker system with audio booster amplifier for Projector<br> | 2 | no | |
| 447 | 15.68 | od307083/2019_2020 : Supply, Installation of HDMI cable - 15 metr<br> | 2 | no | |
| 448 | 15.69 | od307084/2019_2020 : Supply, Installation of VGA cable - 15 Meter<br> | 2 | no | |
| 449 | 15.7 | od307087/2019_2020 : Supply, Installation of USB cable - 15 Meter<br> | 2 | no | |
| 450 | 15.71 | MISCELLANEOUS | |||
| 451 | 15.72 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 1500 | metre | |
| 452 | 15.73 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 2100 | metre | |
| 453 | 15.74 | od307445/2019_2020 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br><br>150 mm width X 50 mm depth X 1.6 mm thickness<br> | 180 | metre | |
| 454 | 15.75 | od307643/2019_2020 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br>100 mm width X 50 mm depth X 1.6 mm thickness<br> | 250 | metre | |
| 455 | 15.76 | od307527/2019_2020 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br>50 mm width X 50 mm depth X 1.6 mm thickness | 400 | metre | |
| 456 | 15.77 | od307635/2019_2020 : Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. <br> | 150 | metre | |
| 457 | 16 | INCINERATOR | |||
| 458 | 16.01 | od314949/2019_2020 : 1067 X 1067 X 1219 ( mm) Combustion chamber<br>Double Chamber as per the notification of PCB. 1067 X 1067 X 610 ( mm) Ash Chamber. Air pollution control devices - Emergency stack, scrubber and moisture seperator. Inside lined with Alumina Standard firebrick (50%) with an insulation of cold face insulation brick & powder <br>and final structure made by 4mm 304grade SS Sheets. Air inlets will be provided for no fuel burning of plant. Chimney : Made of corrosion free Carbon Steel chimney of dia. 210 mm with 6mm thickness and <br>20 meter height.. On that first 10 meter will be cone portion. Cone bottom dia will be 24 inch & <br>top dia will be 9 inch. <br> Grill : 20 mm Mild Steel<br> Doors : 6 mm thickness Stainless steel molded with fire concrete and heat resisting 'insulate 11'.<br>Diesel Burner : Monobloc Fully automatic burner<br> | 1 | no | |
| 459 | 17 | High Side Items | |||
| 460 | 17.01 | od129451/2020_2021 : Supply ,Installation and testing and commissioning of Water Cooled Screw Chillers complete with compressor,evaporator and condenser, microprocessor based graphic control panel, I" deflection spring isolators/neoprin rubber pads,VFD starter ,cooler insulation, victaulic couplings and flow swith, with refrigerant of R134a/R407c, conforming to the specifications and in accordance with the requirements of the schedule of Equipment, suitable to meet the design intent. The chiller shall be supplied fully assembled and tested, BMS compactability with MODBUS factory insulation of cold sufaces with nitrile rubber insulation DP Switches, anty freeze thermostats with grooved end pipe connectios, refrigerant and oil with necessary support and accessories. The chillers shall meet the specified IKW / TR , at full load and part loads, relavant documents to be submitted in the tender to substantiate the preformances. The Hvac contractor to include for relevant isolator and cabling between isolator and the chiller panel. Water cooled screw chiller 135 TR Capacity (1 Working + 1 Stand by) | 2 | no | |
| 461 | 17.02 | od129476/2020_2021 : Supply ,Installation and testing and commissioning of Cooling Towers: forced draft/induced draft counterflow type cooling tower of the specified make and capacity, fixed speed fans, with basin, for 135 TR capacity,inline with the specifications with necessary support and accessories. Special care in the selections is mandatory to ensure you shall provide the chiller with the design condenser entry temperatures, ensure that the noise levels are within acceptable limits.135 TR Capacity Cooling Tower ( 1 Working + 1 Standby ) | 2 | no | |
| 462 | 17.03 | od129758/2020_2021 : Supply ,Installation and testing and commissioning of Condenser water Pumpset-Variable speed end suction back pullout type pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule.all electrical cabling from the VFD panel to the relevant pumps with suitable isoaltors, including VFD's to be priced under this scope with necessary support and accessories. The Electrical contractor shall provide and terminate the cabling from their Main panel to the pump VFD cum control panelCondenser Water Pumps Flowrate : 540 USGPM Head : 35m MOC: CI Pump Housing & Bronze Impeller ( 1 Working + 1 Standby ) | 2 | no | |
| 463 | 17.04 | od129759/2020_2021 : Supply ,Installation and testing and commissioning of Secondary CHW Pumpset- Variable speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule.. electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary supports and accessories. The Electrical contractor shall provide and terminate the cabling from their Main panel to the pump control panel Secondary Chilled Water Pumps Flowrate : 324 USGPM Head : 30 m MOC: CI Pump Housing & Bronze Impeller ( 1 Working + 1 Standby ) | 2 | no | |
| 464 | 17.05 | od129760/2020_2021 : Supply ,Installation and testing and commissioning of Primary CHW Pumpset- Constant speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule.. electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary support and accessories. The Electrical contractor shall provide and terminate the cabling from their Main panel to the pump control panel\nPrimary Chilled Water Pumps Flowrate : 324 USGPM Head : 15m MOC: CI Pump Housing & Bronze Impeller ( 1 Working + 1 Standby ) | 2 | no | |
| 465 | 17.06 | 16.3.7 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of Nominal size - 125mm dia. (50mm thick expanded polysterene) | 198 | metre | |
| 466 | 17.07 | 16.3.8 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene) | 24 | metre | |
| 467 | 17.08 | 16.3.9 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dia. (50mm thick expanded polysterene) | 162 | metre | |
| 468 | 17.09 | 16.3.10 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia.(50mm thick expanded polysterene) | 96 | metre | |
| 469 | 17.1 | 16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene) | 150 | metre | |
| 470 | 17.11 | 16.3.12 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick expanded polysterene) | 156 | metre | |
| 471 | 17.12 | 16.3.13 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 32mm dia. (50mm thick expanded polysterene) | 168 | metre | |
| 472 | 17.13 | 16.3.14 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>\nNote:- The pipes of sizes 150 mm & below shall be M.S.'C\" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick expanded polysterene) | 266 | metre | |
| 473 | 17.14 | od129762/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.<br>20 mm dia. (50 mm thick insulation) | 42 | RM | |
| 474 | 17.15 | 16.7.1.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .Butterfly valve (Manual) 125 mm | 14 | each | |
| 475 | 17.16 | 16.7.1.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .BUTTERFLY VALVE (MANUAL) 100 mm | 2 | each | |
| 476 | 17.17 | 16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .BUTTERFLY VALVE (MANUAL) 80 mm | 6 | each | |
| 477 | 17.18 | 16.7.1.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .BUTTERFLY VALVE (MANUAL) 50mm | 6 | each | |
| 478 | 17.19 | 16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .Butterfly valve (Manual) 40 mm | 18 | each | |
| 479 | 17.2 | od129764/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot water circulation as specified, 15 mm dia. | 210 | no | |
| 480 | 17.21 | od129765/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot water circulation as specified,20 mm dia. | 10 | no | |
| 481 | 17.22 | od129766/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot eater circulation as specified, 25 mm dia. | 34 | no | |
| 482 | 17.23 | od129767/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot water circulation as specified, 32 mm dia. | 12 | no | |
| 483 | 17.24 | 16.7.3.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 125 mm dia | 4 | each | |
| 484 | 17.25 | 16.7.2.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility of 125 mm dia | 2 | each | |
| 485 | 17.26 | 16.7.2.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 100 mm dia | 1 | each | |
| 486 | 17.27 | 16.7.2.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 80 mm dia | 3 | each | |
| 487 | 17.28 | od129768/2020_2021 : Supplying, fixing, testing and commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.32 mm dia | 1 | no | |
| 488 | 17.29 | 16.11.4.6 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1650mm dia. | 3 | each | |
| 489 | 17.3 | 16.11.4.7 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1640mm dia. | 9 | each | |
| 490 | 17.31 | 16.11.4.8 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1632mm dia. | 5 | each | |
| 491 | 17.32 | 16.11.4.9 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1625mm dia. | 17 | each | |
| 492 | 17.33 | 16.11.4.10 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1620mm dia. | 5 | each | |
| 493 | 17.34 | 16.7.4.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 125 mm dia | 4 | each | |
| 494 | 17.35 | 16.7.4.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of Ductile of 50 mm dia | 3 | each | |
| 495 | 17.36 | 16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 40 mm dia | 9 | each | |
| 496 | 17.37 | od129873/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.20 mm Dia | 5 | no | |
| 497 | 17.38 | od129874/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.25 mm Dia | 17 | no | |
| 498 | 17.39 | od129875/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.32 mm Dia | 5 | no | |
| 499 | 17.4 | od129878/2020_2021 : Supplying, fixing, testing and commissioning of RUBBER BELLOW Insulation as shown and as specified in the specifications and drawings with all necessary Support, 125 mm dia. | 12 | no | |
| 500 | 17.41 | od129879/2020_2021 : Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with insulation, CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required with necessary support and accessories, 125 mm dia. | 2 | no | |
| 501 | 17.42 | 16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required | 100 | each | |
| 502 | 17.43 | 16.9 : Providing & fixing in position the mercury in glass industrial type thermometers. | 85 | each | |
| 503 | 17.44 | od129906/2020_2021 : Supplying, fixing, testing and commissioning of flow switch on pipes of suitable dia Rmtras shown and as specified in the specifications and drawings | 2 | no | |
| 504 | 17.45 | od129907/2020_2021 : Supplying, fixing, testing and commissioning Automatic Air release vents with valve on pipes of suitable diaRmtrs as shown and as specified in the specifications and drawings. | 55 | no | |
| 505 | 17.46 | 16.10.1.4 : Condenser water pipesSupplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted / buried in ground excavation and refilling etc. as per specification and as required complete in all respect.\nNote : The pipes size 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7 mm thick MS sheet for pipes of 400 mm dia and aboveCondenser water piping of nominal size - 150 mm dia | 210 | metre | |
| 506 | 17.47 | 16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia | 12 | each | |
| 507 | 17.48 | od129935/2020_2021 : Supplying, fixing, testing and commissioning of RUBBER BELLOW Insulation as shown and as specified in the specifications and drawings with all necessary Support,150 mm dia. | 8 | no | |
| 508 | 17.49 | od129936/2020_2021 : Supplying, fixing, testing and commissioning of Y-STRAINER Insulation as shown and as specified in the specifications and drawings with all necessary Support.150 mm dia. | 2 | no | |
| 509 | 17.5 | od129937/2020_2021 : Supplying, fixing, testing and commissioning of BALANCING VALvE Insulation as shown and as specified in the specifications and drawings with all necessary Support.150 mm dia. | 2 | no | |
| 510 | 17.51 | 16.11.2.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Non- Return Valve with dual plate of C I body S S plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.Non- Return Valve of 150 mm dia | 2 | each | |
| 511 | 17.52 | 16.11.3.5 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.150mm dia. | 2 | each | |
| 512 | 17.53 | od129971/2020_2021 : Supply installation testing and commissioning of Automatic type Chemical dosing system, for chilled water piping and cooling tower piping system as per specification and drawing. | 1 | no | |
| 513 | 17.54 | od129972/2020_2021 : Supply Instalaltion testing and commissioning of Chilled water pressurisation unit system comprising of Closed Expansion Tank with Membrane of suitable capacity-500 litres, Safety Valve-PN 10, Centrifugal Air Separator with valves & accessories, Pumping systems with automatic controls, control panel, pressure transmittors, inter connecting piping and wiring to meet the requirements of the building system volume. The HVAC contractors to evaluate and verify the building system volume and appropriately select the system to meet the deisgn intent. | 1 | no | |
| 514 | 17.55 | od129973/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories.20mm Dia | 300 | metre | |
| 515 | 17.56 | od129974/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories,25mm Dia | 200 | metre | |
| 516 | 17.57 | od129975/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories,32mm Dia. | 100 | metre | |
| 517 | 17.58 | Low Side items | |||
| 518 | 17.59 | 16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006\nGSS 0.63mm thickness\n | 1370 | sqm | |
| 519 | 17.6 | 16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006\nGSS 0.80mm thickness | 30 | sqm | |
| 520 | 17.61 | od129970/2020_2021 : Supply & Installation testing and commissioning of Aluminum duct work in Operation theatres of following Gauges asappropiate with all accessories, supports, jointing materials, flanges complete all inline with theDW 144 or SMACNA and in line with the specifications, drawings etc, 22 Gauge | 425 | sqm | |
| 521 | 17.62 | 16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper | 30 | sqm | |
| 522 | 17.63 | 16.15 : Suppluying and Fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | 10 | sqm | |
| 523 | 17.64 | 16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core. | 20 | sqm | |
| 524 | 17.65 | 16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core. | 20 | sqm | |
| 525 | 17.66 | od129943/2020_2021 : Acoustic Insulation using nitrile rubber, open cell foam, fibre free, minimum density of 140 kg/cu.m should have microban, as per ASTM G-21, ASTM E-2180, thermal conductivity not exceeding 0.047 W/m.K at 20 C, conform to class 1 rating for flame spread in accordance to BS 476 part 7, to thickness of minimum of 10mm all inline with the specificatoin and to meet the design noise criteria.Acoustic liner | 171 | sqm | |
| 526 | 17.67 | od129944/2020_2021 : Ductwork Insulation- Supplying, fixing testing commissioning of Closed cell elastomeric nitrile rubber insulation of specific thickness on existing duct after applying suitable adhesive for Nitrile rubber,The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape inline with the specifications, drawings as follows with necessary support and accessories.Under deck insulation.(Thickness-25 mm) | 115 | sqm | |
| 527 | 17.68 | od129945/2020_2021 : Ductwork Insulation- Supplying, fixing testing commissioning of Closed cell elastomeric nitrile rubber insulation of specific thickness on existing duct after applying suitable adhesive for Nitrile rubber,The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape inline with the specifications, drawings as follows with necessary support and accessories.Fresh and exhaust ductwork complete running in Air-Conditioned space.(Thickness-19 mm) | 65 | sqm | |
| 528 | 17.69 | od129946/2020_2021 : Ductwork Insulation- Supplying, fixing testing commissioning of Closed cell elastomeric nitrile rubber insulation of specific thickness on existing duct after applying suitable adhesive for Nitrile rubber,The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape inline with the specifications, drawings as follows with necessary support and accessories.Supply and Return ductwork complete running in Air-Conditioned space (Thickness-13 mm) | 965 | sqm | |
| 529 | 17.7 | od129949/2020_2021 : Supply installation testing and commissioning of Strip Heater 1.5KW x 4Nos with humidistat, senseor, cabling , all necessary support and accessories | 8 | no | |
| 530 | 17.71 | od129950/2020_2021 : Supply, installation, testing and commissioning of Unidirectional Laminar flow plenum for the OT's with HEPA filters .• Plenum Construction : 1 mm Aluminium construction having Aluminium Square tube skeleton structure• Perforated diffuser: 1 mm Stainless Steel (SS-304) Inline Round Perfoaration : 5mm ø,12 mm Pitch• Note: Plenum will be shipped in one single plenum at the site.• Filter fitment : Filter face seating on a self-leveling Poly Urethene compound formed on the Plenum structure. • Thermal insulation : 19 mm thick Class "O" Nitrile insulation with aluminium foil lamination on exterior side.• Duct connecting collar : No. of Duct connecting Collars -Based on user requirements Maximum Height : 225 mm • Volume control dampers : Aluminium Aerofoil Volume Control Damper Operable from the OT side without distrubing filter installation.•UP stream ports : Provision of Up stream ports for Testing & Measurement.• Provision for OT light pendent : Will be Provided. Chute opening Size-520 x 520 mm• Suspension brackets : SS "L" angle brackets for ceiling suspension of the Plenum.•Terminal Air Filter : HEPA filter as per description below• Mini Pleat HEPA Filters, Flange typeCasing : Anodised Aluminium extruded profile - Flange typeMedia : Micro Glass Fibre of "Lydall, France" makePack Depth: 50 mmSealant : PU SealantGasket : 3mm thick XLPEFace Guard : Powder coated, Aluminium flattened expanded metal on both sides of the filtration media pack.Particle size efficiency : ≥ 99.99% @ 0.3 microns .Maximum operating temperature : 50º CEquivalent to : H14 of EN1822-1 TYPE 'D' of TEST - RP - CC - 001.5• Plenum Size: 2350 (L) x 1740 (W) x 455 (H) mm (Excluding Thermal Insulation) • Perforated Diffuser size : 2440 (L) x 1830 (W) mm• Filter Nominal Sizes : 1) 4' x 2' - 4 Nos. 2) 3' x 2' - 2 Nos.HEPA Filter testing standards : IEST : RP : CC : 034,<br>2440 x 1830 x 450mm . | 4 | no | |
| 531 | 17.72 | Equipment | |||
| 532 | 17.73 | od129537/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan, coil piping connections, condensate drain connections, mixing box with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, AHU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty. The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415 +/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.HVAC contractor to check the ahu room sizes during the AHU selections/sizing, and shall strictly follow the AHU room sizing, as no changes whatsoever shall be acceptable.The ahu shall be mounted on custom buillt steel plat forms with provided with walk ways guide rails etc. Units shall be installed as shown in the drawings and Sound Attenuators as applicable to meet the design noise criteria as specified for the capacities as under.7.4 TR, 3990 CFM | 1 | no | |
| 533 | 17.74 | od129960/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)6.8 TR, 3789 CFM, | 1 | no | |
| 534 | 17.75 | od129539/2020_2021 : Supply ,Installation and testing and commissioning of Horizontal Floor mounted Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan, coil piping connections, condensate drain connections, mixing box with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, AHU, PICV as shown in the drawings and specifications. The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415 +/-10% volts and required lengths of wiring as per site requirement to be included. Electrical panel with VFD to be provided to suitable for the machine capacty.The electrical power wiring from the Isolator to the units shall be included.HVAC contractor to check the ahu room sizes during the AHU selections/sizing, and shall strictly follow the AHU room sizing, as no changes whatsoever shall be acceptable.The ahu shall be mounted on custom buillt steel plat forms with provided with walk ways guide rails etc. Units shall be installed as shown in the drawings and Sound Attenuators as applicable to meet the design noise criteria as specified for the capacities as under.8.0 TR, 4157 CFM | 1 | no | |
| 535 | 17.76 | od129540/2020_2021 : Supply ,Installation and testing and commissioning of Horizontal Floor mounted Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan, coil piping connections, condensate drain connections, mixing box with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, AHU, PICV as shown in the drawings and specifications. The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415 +/-10% volts and required lengths of wiring as per site requirement to be included. Electrical panel with VFD to be provided to suitable for the machine capacty.The electrical power wiring from the Isolator to the units shall be included.HVAC contractor to check the ahu room sizes during the AHU selections/sizing, and shall strictly follow the AHU room sizing, as no changes whatsoever shall be acceptable.The ahu shall be mounted on custom buillt steel plat forms with provided with walk ways guide rails etc. Units shall be installed as shown in the drawings and Sound Attenuators as applicable to meet the design noise criteria as specified for the capacities as under.7.0 TR, 3865 CFM | 2 | no | |
| 536 | 17.77 | od129550/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)11.3 TR, 2694 CFM | 2 | no | |
| 537 | 17.78 | od129551/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)5.2 TR, 1568 CFM | 1 | no | |
| 538 | 17.79 | od129552/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)4.1 TR, 1252 CFM | 1 | no | |
| 539 | 17.8 | od129553/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.6 TR, 877 CFM | 1 | no | |
| 540 | 17.81 | od129554/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)3.0 TR, 981 CFM | 1 | no | |
| 541 | 17.82 | od129555/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)3.6 TR, 1497 CFM | 1 | no | |
| 542 | 17.83 | od129556/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.4 TR, 849 CFM | 1 | no | |
| 543 | 17.84 | od129557/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.6 TR, 905 CFM | 1 | no | |
| 544 | 17.85 | od129558/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.6 TR, 1110 CFM | 1 | no | |
| 545 | 17.86 | od129559/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.2 TR, 791 CFM | 1 | no | |
| 546 | 17.87 | od129560/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.2 TR, 980 CFM | 1 | no | |
| 547 | 17.88 | od129561/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)3.0 TR, 1305 CFM | 1 | no | |
| 548 | 17.89 | od129562/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)2.4 TR, 1092 CFM | 1 | no | |
| 549 | 17.9 | od129563/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)6.7 TR, 4734 CFM | 1 | no | |
| 550 | 17.91 | od129564/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)9.5 TR, 2661 CFM | 1 | no | |
| 551 | 17.92 | od129565/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)11 TR, 3907 CFM | 1 | no | |
| 552 | 17.93 | od129566/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)8.2 TR, 2488 CFM | 1 | no | |
| 553 | 17.94 | od129567/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)4.4 TR, 2326 CFM | 1 | no | |
| 554 | 17.95 | od129568/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)6.8 TR, 3282 CFM | 1 | no | |
| 555 | 17.96 | od129569/2020_2021 : Supply ,Installation and testing and commissioning of Ceiling Suspended horizontal low height, low noise type Air Handling Units (complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, CSU, PICV as shown in the drawings and specifications. Electrical panel with VFD to be provided to suitable for the machine capacty.The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-)3.6 TR,1145 CFM | 1 | no | |
| 556 | 17.97 | od129635/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-2.9 TR, 971 CFM | 1 | no | |
| 557 | 17.98 | od129636/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-3.1 TR, 980 CFM | 1 | no | |
| 558 | 17.99 | od129637/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.4 TR, 620 CFM | 1 | no | |
| 559 | 18 | od129638/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.8 TR, 718 CFM | 1 | no | |
| 560 | 18.01 | od129639/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.8 TR, 694 CFM | 1 | no | |
| 561 | 18.02 | od129640/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-2.5 TR, 1129 CFM | 1 | no | |
| 562 | 18.03 | od129959/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.5 TR, 594 CFM | 1 | no | |
| 563 | 18.04 | od129642/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:1.6 TR, 626 CFM | 1 | no | |
| 564 | 18.05 | od129643/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.6 TR, 622 CFM | 1 | no | |
| 565 | 18.06 | od129644/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-1.2 TR, 518 CFM | 1 | no | |
| 566 | 18.07 | od129645/2020_2021 : Supply , installation testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with damper( as applicable)s, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications.electrical panel to be suppilied The duties of equipments listed below and accessories shall be as per equipment schedule. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring as per site requirement to be included. Units shall be installed as shown in the drawing,(STATIC-70 MM TO 100 MM Pascal) capacities as under:-2.0 TR, 850 CFM | 1 | no | |
| 567 | 18.08 | od129646/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:940 CFM | 1 | no | |
| 568 | 18.09 | od129647/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:810 CFM | 1 | no | |
| 569 | 18.1 | od129648/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:800 CFM | 1 | no | |
| 570 | 18.11 | od129649/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:630 CFM | 1 | no | |
| 571 | 18.12 | od129650/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:600 CFM | 3 | no | |
| 572 | 18.13 | od129651/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:545 CFM | 1 | no | |
| 573 | 18.14 | od129652/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:450 CFM | 4 | no | |
| 574 | 18.15 | od129653/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:435 CFM | 1 | no | |
| 575 | 18.16 | od129654/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:430 CFM | 1 | no | |
| 576 | 18.17 | od129655/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:400 CFM | 4 | no | |
| 577 | 18.18 | od129656/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:380 CFM | 1 | no | |
| 578 | 18.19 | od129657/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:350 CFM | 4 | no | |
| 579 | 18.2 | od129658/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:330 CFM | 1 | no | |
| 580 | 18.21 | od129659/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:300 CFM | 2 | no | |
| 581 | 18.22 | od129660/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2800 CFM | 1 | no | |
| 582 | 18.23 | od129661/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:275 CFM | 1 | no | |
| 583 | 18.24 | od129662/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:250 CFM | 1 | no | |
| 584 | 18.25 | od129663/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:200 CFM | 8 | no | |
| 585 | 18.26 | od129664/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1800 CFM | 1 | no | |
| 586 | 18.27 | od129665/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:180 CFM | 4 | no | |
| 587 | 18.28 | od129958/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1575 CFM | 1 | no | |
| 588 | 18.29 | od129666/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1282 CFM | 1 | no | |
| 589 | 18.3 | od129667/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1250 CFM | 1 | no | |
| 590 | 18.31 | od129668/2020_2021 : Supply ,Installation testing & commissioning of Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1040 CFM | 1 | no | |
| 591 | 18.32 | od129961/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:575 CFM | 1 | no | |
| 592 | 18.33 | od129962/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:1282 CFM | 1 | no | |
| 593 | 18.34 | od129963/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:2427 CFM | 1 | no | |
| 594 | 18.35 | od129964/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:1333 CFM | 1 | no | |
| 595 | 18.36 | od129965/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:646 CFM | 1 | no | |
| 596 | 18.37 | od129977/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:1147 CFM | 1 | no | |
| 597 | 18.38 | od129967/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:435 CFM | 1 | no | |
| 598 | 18.39 | od129968/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:1376 CFM | 1 | no | |
| 599 | 18.4 | od129969/2020_2021 : Supply installation testing and commissioning of Inline Centrifugalfresh air Fans shall be with direct driven centrifugal fan with starter panel and cabling, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out A. as specified and as indicated in the equipment schedules and drawings for the following:304 CFM | 1 | no | |
| 600 | 18.41 | od129976/2020_2021 : Supply installation testing and commissioning of wall mounted propeller fan with necessary support and accessories | 25 | no | |
| 601 | 19 | oxygen supply sysyem | |||
| 602 | 19.01 | od306184/2019_2020 : Supply, Installation, Testing and commissioning of Duplex Mediacl grade Oxygen Generator system with all required accessories to ensure Medical grade oxygen and as per HTM 02-01 standard including electrical control panel including starter and necessary connections etc. The ogygen generator shall be class 2 certified medical devise. The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to the European Pharmacopoeia as per the tech spec. Each generator should have minimum oxygen delivery of 1550 LPM . Third party certification to be produced for medical grade oxygen quality and design output flow value verification. | 1 | no | |
| 603 | 19.02 | od306191/2019_2020 : Supply, Installation, Testing and commissioning of fullyautomatic Oxygen Control Panel with minimum flow rate of 1520 LPM | 1 | no | |
| 604 | 19.03 | od306258/2019_2020 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 20 cylinders with all accessories etc.<br> | 1 | no | |
| 605 | 19.04 | od306188/2019_2020 : Supply, Installation, Testing and commissioning of Emergency Cylinder Manifold 2 bank x 4 cylinders with emergency Oxygen high flow regulator with gauges and safety valves with all accessories etc. | 1 | no | |
| 606 | 19.05 | Nitrous Oxide Supply system | |||
| 607 | 19.06 | od306192/2019_2020 : Supply, Installation, Testing and commissioning of Semi automatic N2O Control Panel with minimum flow rate of 105 LPM | 1 | no | |
| 608 | 19.07 | od306193/2019_2020 : Supply, Installation, Testing and commissioning of N2O Manifold - 2 banks x 4 cylinders with all accessories etc. | 1 | no | |
| 609 | 19.08 | od306194/2019_2020 : Supply, Installation, Testing and commissioning of Emergency N2O Cylinder Manifold -1 bank x 2cylinders with emergency N2O high flow regulator with gauges and safety valves with all accessories etc. | 1 | no | |
| 610 | 19.09 | Carbon dioxide Supply System | |||
| 611 | 19.1 | od306195/2019_2020 : Supply, Installation, Testing and commissioning of Semi automatic CO2 Control Panel with minimum flow rate of 80LPMN | 1 | no | |
| 612 | 19.11 | od306196/2019_2020 : Supply, Installation, Testing and commissioning of CO2 Manifold - 2 banks x 2 cylinders with all accessories etc. | 1 | no | |
| 613 | 19.12 | Nitrogen Supply System | |||
| 614 | 19.13 | od306197/2019_2020 : Supply, Installation, Testing and commissioning of Semi automatic Nitrogen Control Panel with minimum flow rate of 80LPM | 1 | no | |
| 615 | 19.14 | od306198/2019_2020 : Supply, Installation, Testing and commissioning of Nitrogen Manifold - 2 banks x 2 cylinders with all accessories etc.<br> | 1 | no | |
| 616 | 19.15 | Compressed Air Plant | |||
| 617 | 19.16 | od306199/2019_2020 : Supply, Installation, Testing and commissioning of Duplex Mediacl grade compressed Air System must have 2 nos reciprocating oil free medical grade screw compressor in compact super sound absorbing tower design complete with all required cooling, control and monitoring facilities for operations in system with 2 compressors, a control panel, 1 air receivers 1500 L., 2 Dryer and double filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station, electrical control panel including starter and necessary connections etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to the European Pharmacopoeia as per the tech spec.. Each compressor should have minimum FAD of 1930 LPM (68CFM). Third party certification to be produced for medical grade air quality and compressor FAD capacity verification.<br> | 1 | no | |
| 618 | 19.17 | Vacuum Plant | |||
| 619 | 19.18 | od306200/2019_2020 : Supply, Installation, Testing and commissioning of Medical grade Triplex Vacuum System must have 3 rotary vane type vacuum pumps directly driven by motor, a control panel, 2 set of vacuum receivers 2000 Ltr., secretion Traps and bacteria filters, electrical control panel including starter and necessary connections etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99. each vacuum pump should have FAA 4215 LPM at 450mmHg, Third party certification to be produced for medical grade vaccum quality and pump design flow capacity verification.<br> | 1 | no | |
| 620 | 19.19 | WAGD System | |||
| 621 | 19.2 | od306201/2019_2020 : Supply, Installation, Testing and commissioning of pendant operated WAGD SYSTEM (meeting ISO 7396-2/HTM02-01)<br> | 4 | no | |
| 622 | 19.21 | Area control unit (Area alarm + Area valves) | |||
| 623 | 19.22 | od306202/2019_2020 : Supply, Installation, Testing and commissioning of Area Control Unit for 1 Gases (O2) and 1 Vac (DN 20)<br> | 1 | no | |
| 624 | 19.23 | od306203/2019_2020 : Supply, Installation, Testing and commissioning of Area Control Unit for 2 Gases (O2, Air) and 1 Vac (DN 20)<br> | 9 | no | |
| 625 | 19.24 | od306204/2019_2020 : Supply, Installation, Testing and commissioning of Area Control Unit for 3 Gases (O2, Air4,N2O) and 1 Vac (DN 20)<br> | 1 | no | |
| 626 | 19.25 | od306205/2019_2020 : Supply, Installation, Testing and commissioning of Area Control Unit for 6 Gases (O2, Air4, Air 7,N2O, CO2, N) and 1 Vac <br> | 4 | no | |
| 627 | 19.26 | Isolation valves | |||
| 628 | 19.27 | od306206/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 15 - 15x1<br> | 9 | no | |
| 629 | 19.28 | od306207/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 20 - 22x1<br> | 11 | no | |
| 630 | 19.29 | od306208/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 25 - 28x1,5<br> | 5 | no | |
| 631 | 19.3 | od306209/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 32 - 35x1,5<br> | 2 | no | |
| 632 | 19.31 | od306210/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 40 - 42x1,5<br> | 2 | no | |
| 633 | 19.32 | od306211/2019_2020 : Supply, Installation, Testing and commissioning of Ball Valve, DN 42 - 54x1,5<br> | 1 | no | |
| 634 | 19.33 | Terminal units Wall mounted - BS standard | |||
| 635 | 19.34 | od306217/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit O2<br> | 248 | no | |
| 636 | 19.35 | od306218/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit N2O<br> | 5 | no | |
| 637 | 19.36 | od306219/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit Air 400<br> | 116 | no | |
| 638 | 19.37 | od306220/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit Air 700<br> | 5 | no | |
| 639 | 19.38 | od306221/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit Vac<br> | 247 | no | |
| 640 | 19.39 | od306222/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit N<br> | 4 | no | |
| 641 | 19.4 | od306223/2019_2020 : Supply, Installation, Testing and commissioning of Terminal Unit CO2<br> | 4 | no | |
| 642 | 19.41 | od306224/2019_2020 : Supply, Installation of Probes<br> | 550 | no | |
| 643 | 19.42 | Bed head panels | |||
| 644 | 19.43 | od306225/2019_2020 : Supply, Installation, Testing and commissioning of Horizontal Bed Head Panels of 3 feet long with provision for 3 nos electrical (power & data) & min 3 nos Gas outlets - as per technical specification for Post operative beds<br> | 2 | no | |
| 645 | 19.44 | od306226/2019_2020 : Supply, Installation, Testing and commissioning of Horizontal Bed Head Panels of 4 feet long with provision for 3 nos electrical (power & data) & min 5 nos Gas outlets - as per technical specification for ICU beds<br> | 3 | no | |
| 646 | 19.45 | od306243/2019_2020 : Supply, Installation, Testing and commissioning of Continous Bed head panel with provision for fixing Medical gas outlets, power sockets, nurse cal points etc. as per the design requrement.<br> | 250 | metre | |
| 647 | 19.46 | Pendants | |||
| 648 | 19.47 | od306244/2019_2020 : Supply, installation, testing and commissioning of Anaesthesia Pendant - Single Arm with all required accessories<br> | 4 | no | |
| 649 | 19.48 | od306245/2019_2020 : Supply, installation, testing and commissioning of Surgeon's Pendant - Single Arm with all required accessories<br> | 3 | no | |
| 650 | 19.49 | Medical Equipments | |||
| 651 | 19.5 | od306228/2019_2020 : Supply, installation, testing and commissioning of Oxygen Flow meter with humidifier bottle. Matching probe / adaptor shall be provided at one end suitable for Oxygen Gas Outlets and other end for flow meter.<br> | 100 | no | |
| 652 | 19.51 | od306229/2019_2020 : Supply, installation, testing and commissioning of Ward Suction Unit with 1200 ml suction jar as per specifications. Matching proble / adaptor shall be provided at one end suitable for vacuum gas outlets and other end for Vacuum Hose.<br> | 100 | no | |
| 653 | 19.52 | od306230/2019_2020 : Supply, installation, testing and commissioning of Theatre Suction Unit with 3200 ml jars as per specifications. Matching probe / adaptor shall be provided at one end suitable for Vacuum Gas outlets and other end for Vacuum Hose including trolley.<br> | 4 | no | |
| 654 | 19.53 | Master plant alarm | |||
| 655 | 19.54 | od306231/2019_2020 : Supply, installation, testing and commissioning of Master plant alarm<br> | 1 | no | |
| 656 | 19.55 | Copper Piping As per EN13348 standards. | |||
| 657 | 19.56 | od306246/2019_2020 : Supply, installation, testing and commissioning of 12mm dia copper piping<br> | 108 | metre | |
| 658 | 19.57 | od306247/2019_2020 : Supply, installation, testing and commissioning of 15mm dia copper piping<br> | 1877 | metre | |
| 659 | 19.58 | od306248/2019_2020 : Supply, installation, testing and commissioning of 22mm dia copper piping<br> | 1259 | metre | |
| 660 | 19.59 | od306249/2019_2020 : Supply, installation, testing and commissioning of 28mm dia copper piping | 230 | metre | |
| 661 | 19.6 | od306250/2019_2020 : Supply, installation, testing and commissioning of 35mm dia copper piping<br> | 68 | metre | |
| 662 | 19.61 | od306251/2019_2020 : Supply, installation, testing and commissioning of 42mm dia copper piping<br> | 41 | metre | |
| 663 | 19.62 | od306255/2019_2020 : Supply, installation, testing and commissioning of 54mm dia copper piping<br> | 19 | metre | |
| 664 | 20 | Electrical items | |||
| 665 | 20.01 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C | 911 | point | |
| 666 | 20.02 | 1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 824 | point | |
| 667 | 20.03 | 1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 5 | point | |
| 668 | 20.04 | 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 8189 | metre | |
| 669 | 20.05 | 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 6761 | metre | |
| 670 | 20.06 | 1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 4025 | metre | |
| 671 | 20.07 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 1922 | metre | |
| 672 | 20.08 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 1565 | metre | |
| 673 | 20.09 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 881 | metre | |
| 674 | 20.1 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 550 | metre | |
| 675 | 20.11 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 285 | metre | |
| 676 | 20.12 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 180 | metre | |
| 677 | 20.13 | 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 221 | each | |
| 678 | 20.14 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 375 | each | |
| 679 | 20.15 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 769 | each | |
| 680 | 20.16 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 477 | each | |
| 681 | 20.17 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | 769 | each | |
| 682 | 20.18 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 477 | each | |
| 683 | 20.19 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | 24 | each | |
| 684 | 20.2 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 27 | each | |
| 685 | 20.21 | 1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) | 5 | each | |
| 686 | 20.22 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | 123 | each | |
| 687 | 20.23 | 1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module | 1 | each | |
| 688 | 20.24 | 1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module | 10 | each | |
| 689 | 20.25 | 1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module | 132 | each | |
| 690 | 20.26 | 1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module | 204 | each | |
| 691 | 20.27 | 1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module | 214 | each | |
| 692 | 20.28 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). | 592 | each | |
| 693 | 20.29 | 1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 316 | each | |
| 694 | 20.3 | 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. | 421 | each | |
| 695 | 20.31 | 1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required. | 5 | each | |
| 696 | 20.32 | 1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. | 1 | each | |
| 697 | 20.33 | 1.39 : Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor / wall, or side of the table / door etc. as required. | 5 | metre | |
| 698 | 20.34 | 1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required. | 110 | metre | |
| 699 | 20.35 | 1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 1418 | each | |
| 700 | 20.36 | 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door | 1 | each | |
| 701 | 20.37 | 1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required. | 221 | no | |
| 702 | 20.38 | 1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | 221 | each | |
| 703 | 20.39 | 1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required. | 1639 | each | |
| 704 | 20.4 | 1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep | 2 | each | |
| 705 | 20.41 | 1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes | 2 | each | |
| 706 | 20.42 | 1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. lCD | 1 | each | |
| 707 | 20.43 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | 1 | each | |
| 708 | 20.44 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 1056 | each | |
| 709 | 20.45 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | 46 | each | |
| 710 | 20.46 | 2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 205 | each | |
| 711 | 20.47 | 2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 5 | each | |
| 712 | 20.48 | 2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps \"C\" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 1 | each | |
| 713 | 20.49 | 2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | 11 | each | |
| 714 | 20.5 | 2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | 2 | each | |
| 715 | 20.51 | 2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. | 18 | each | |
| 716 | 20.52 | 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required | 5 | set | |
| 717 | 20.53 | 5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 1 | set | |
| 718 | 20.54 | 5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 1 | metre | |
| 719 | 20.55 | 5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. | 1 | metre | |
| 720 | 20.56 | 5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. | 2 | metre | |
| 721 | 20.57 | 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mm | 768 | metre | |
| 722 | 20.58 | 7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm | 10 | metre | |
| 723 | 20.59 | 7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm | 10 | metre | |
| 724 | 20.6 | 7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm | 10 | metre | |
| 725 | 20.61 | 7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm | 10 | metre | |
| 726 | 20.62 | 7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing masonry open duct as required.Upto 35 sq. mm | 270 | metre | |
| 727 | 20.63 | 7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm | 160 | metre | |
| 728 | 20.64 | 7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm | 160 | metre | |
| 729 | 20.65 | 7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm | 120 | metre | |
| 730 | 20.66 | 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) | 959 | metre | |
| 731 | 20.67 | 7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 12 | metre | |
| 732 | 20.68 | 7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | 1 | metre | |
| 733 | 20.69 | 7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) | 36 | metre | |
| 734 | 20.7 | 7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) | 3834 | metre | |
| 735 | 20.71 | 7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 622 | metre | |
| 736 | 20.72 | 7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | 189 | metre | |
| 737 | 20.73 | 7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) | 2108 | metre | |
| 738 | 20.74 | 7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required. | 30 | no | |
| 739 | 20.75 | 8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm | 2 | metre | |
| 740 | 20.76 | 8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm | 20 | metre | |
| 741 | 20.77 | 8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of\nfollowing size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm | 160 | metre | |
| 742 | 20.78 | 9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.2 X 10 sq. mm (19mm) | 4 | set | |
| 743 | 20.79 | 9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 X 16 sq. mm (25mm) | 10 | set | |
| 744 | 20.8 | 9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 35 sq. mm (32mm) | 14 | set | |
| 745 | 20.81 | 9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2 X 50 sq. mm (35mm) | 14 | set | |
| 746 | 20.82 | 9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 70 sq. mm (38mm) | 2 | set | |
| 747 | 20.83 | 9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 95 sq. mm (45mm) | 4 | set | |
| 748 | 20.84 | 9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2 X 120 sq. mm (45mm) | 10 | set | |
| 749 | 20.85 | 9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2 X 150 sq. mm (50mm) | 2 | set | |
| 750 | 20.86 | 9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 185 sq. mm (57mm) | 4 | set | |
| 751 | 20.87 | 9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 240 sq. mm (62mm) | 12 | set | |
| 752 | 20.88 | 9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 300 sq. mm (70mm) | 16 | set | |
| 753 | 20.89 | 9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 400 sq. mm (82mm) | 38 | set | |
| 754 | 20.9 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) | 28 | set | |
| 755 | 20.91 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm) | 38 | set | |
| 756 | 20.92 | 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 25 sq. mm (28mm) | 2 | set | |
| 757 | 20.93 | 10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm | 4 | each | |
| 758 | 20.94 | 15.2 : Supplying, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection .) having high preformance, regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. | 57 | no | |
| 759 | 20.95 | 11.6.2 : Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation\n(during casting) for cable entry including bending the pipe to the required shape complete as required.40 mm dia | 14 | metre | |
| 760 | 20.96 | 9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 35 sq. mm (32mm) | 2 | set | |
| 761 | 20.97 | 9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 X 10 sq. mm (22mm) | 18 | set | |
| 762 | 20.98 | 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 7 | each | |
| 763 | 20.99 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 5 | each | |
| 764 | 21 | od310364/2019_2020 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.<br>120 mm dia (OD-120 mm & ID-103 mm nominal) | 10 | metre | |
| 765 | 21.01 | od310365/2019_2020 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.<br>63 mm dia (OD-63 mm & ID-51 mm nominal) | 450 | metre | |
| 766 | 21.02 | 9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.2 X 6 sq. mm (19mm) | 22 | set | |
| 767 | 21.03 | 1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. | 385 | metre | |
| 768 | 21.04 | 1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet | 11 | each | |
| 769 | 21.05 | od299996/2020_2021 : SECOND FLOOR & THIRD FLOOR PANEL LEFT WING<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and component as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage - 230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>400A 36kA FP Microprocessor Based MCCB - 1 no.<br>400A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>200A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>160A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>125A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>100A 25kA TP Thermal Magnetic Based MCCB - 3 nos | 1 | each | |
| 770 | 21.06 | od299997/2020_2021 : GROUND FLOOR PANEL RIGHT WING<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger noticeboard, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>400A 36kA FP Microprocessor Based MCCB - 1 no.<br>400A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Surge Protection Device Class B & Class C/ Class 1 & Class<br>2 and fuse for protection of the same - 1 set<br>Outgoings<br>250A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>160A 25kA TP Thermal Magnetic Based MCCB - 2 nos.<br>125A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br> | 1 | each | |
| 771 | 21.07 | od299998/2020_2021 : UPS IN PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern<br>fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos.<br>earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This<br>panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level<br><1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for<br>complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>500A, 36kA FP Microprocessor based MCCB with adjustable settings - 1<br>No.<br>500A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>RYB phase indicating LED<br>lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>250A 36kA TP Thermal Magnetic Based MCCB - 3 nos<br>RYB phase indicating LED lamps with control fuses and switches - 3 set. | 1 | each | |
| 772 | 21.08 | od299999/2020_2021 : UPS OUT PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern<br>fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos.<br>earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This<br>panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level<br><1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for<br>complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>250A 36kA FP Thermal Magnetic Based MCCB - 3 nos<br>500A 433V,<br>36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meter with<br>accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral<br>current. Phase angle, THD etc. - 3 No <br>RYB phase indicating LED lamps with control fuses and switches - 3 set.<br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>500A, 36kA FP Microprocessor based MCCB with<br>adjustable settings - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set | 1 | each | |
| 773 | 21.09 | od300000/2020_2021 : UPS MAIN PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern<br>fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos.<br>earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This<br>panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec)<br>for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>500A, 36kA FP Microprocessor based MCCB with adjustable settings - 1 No.<br>500A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>200A 25kA TP Thermal Magnetic Based MCCB - 2 nos<br>125A 25kA TP Thermal Magnetic Based MCCB - 3 nos.<br>100A 25kA TP Thermal Magnetic Based MCCB - 3 nos | 1 | each | |
| 774 | 21.1 | od300001/2020_2021 : GROUND FLOOR PANEL LEFT WING<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min<br>25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are<br>galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice<br>board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time<100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>400A 36kA FP Microprocessor Based MCCB - 1 no.<br>400A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat<br>shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Surge Protection Device Class B & Class C/ Class 1 & Class<br>2 and fuse for protection of the same - 1 set<br>Outgoings<br>200A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>160A 25kA TP Thermal Magnetic Based MCCB - 3 nos.<br>125A 25kA TP Thermal Magnetic Based MCCB - 1 no. | 1 | each | |
| 775 | 21.11 | od300002/2020_2021 : FIRST FLOOR PANEL LEFT WING<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply systemhaving provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning<br>process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates.<br>Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This<br>panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level<br><1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for<br>complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>630A 36kA FP Microprocessor Based MCCB - 1 no.<br>630A 433V, 36kA<br>best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses<br>and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh,<br>Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same -<br>1 set<br>Outgoings<br>320A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>160A 25kA TP Thermal Magnetic Based MCCB - 3 nos<br>125A 25kA TP Thermal Magnetic Based MCCB - 1 no. | 1 | each | |
| 776 | 21.12 | od300003/2020_2021 : Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>4 way Seven Segment DB | 4 | each | |
| 777 | 21.13 | od300004/2020_2021 : Supplying ceiling fan of 1200mm sweep, including the down rod of standard length (upto 30 cm.) including all accesories as required for complete installation | 221 | each | |
| 778 | 21.14 | od300005/2020_2021 : TOD METER<br>Supply, Installation, testing & commissioning of 3 phase 4 way 110V (L-L), 5A, class:<br>0.2, TOD meter with RS485 port, of Electricity board approved make, in existing enclosures of HT Panel<br>including all necessary accessories for fixing and connection complete as required getting tested and<br>approved from statutory authorities, providing connection/inter-connections as required for complete<br>installation and as instructed by engineer in charge/consultant. | 1 | each | |
| 779 | 21.15 | od300287/2020_2021 : 12 WAY UPS SMDB SECOND & THIRD FLOOR LEFT WING<br>Supply, erection, testing and commissioning of floor mounting type, double door 3 phase 12 way SMDB. IP43 ingress protection and quality with cable end boxs, meter module, add on module for adding surge arrestor including busbar, neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. SMDB shall comply with latest IEC 61439-2 standard with full safety reliability test certificates (Dekra and Asta certified). All MCCBs used shall be 100% Ics rated. Short-time withstand current for SMDB should be 36kA for 1s. SMDB shall be supplied with following accesories-<br>250A rated SMDB - 12 way with all accessories - 1 no.<br>Meter extension Box - 1 set<br>1- phase Ammeter - 3 nos<br>Voltmeter with voltage selector switch- 1 no<br>RYB indication lamps - 1 set<br>Side cabling box - 2 nos.<br>Bottom cabling box with provision for adding Surge arrestor alongwith fuses - 1 no <br>Mounting base - 1 no.<br>Corner box - 4 nos<br>Incomer - 200A FP 25kA thermal magnetic releaseMCCB -1No.<br>Outgoings<br>63A 16kA TP MCCB, with thermal magnetic release - 4 nos. <br>32A 16kA TP MCCB, with thermal magnetic release - 8 nos. | 1 | each | |
| 780 | 21.16 | od300288/2020_2021 : 12 WAY UPS SMDB GROUND & FIRST FLOOR LEFT WING<br>Supply, erection, testing and commissioning of floor mounting type, double door 3 phase 12 way SMDB. IP43 ingress protection and quality with cable end boxs, meter module, add on module for adding surge arrestor including busbar, neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. SMDB shall comply with latest IEC 61439-2 standard with full safety reliability test certificates (Dekra and Asta certified). All MCCBs used shall be 100% Ics rated. Short-time withstand current for SMDB should be 36kA for 1s. SMDB shall be supplied with following accesories-<br>250A rated SMDB - 12 way with all accessories - 1 no.<br>Meter extension Box - 1 set<br>1- phase Ammeter - 3 nos<br>Voltmeter with voltage selector switch- 1 no<br>RYB indication lamps - 1 set<br>Side cabling box - 2 nos.<br>Bottom cabling box with provision for adding Surge arrestor alongwith fuses - 1 no <br>Mounting base - 1 no.<br>Corner box - 4 nos<br>Incomer - 200A FP 25kA thermal magnetic release MCCB -1No.<br>Outgoings<br>63A 16kA TP MCCB, with thermal magnetic release - 3 nos. <br>32A 16kA TP MCCB, with thermal magnetic release - 9 nos. | 1 | each | |
| 781 | 21.17 | od300289/2020_2021 : MAIN PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof,floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non<br>load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt commonremote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer - <br>EB Incomer 1 & 2 - 1600A 50kA FP EDO Microprocessor based ACB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing strip, REF protection relay with primary trip. - 2 Nos.<br>DG Incomer 1 & 2 - 1000A 50 kA FP ACB EDO Microprocessor based - 2 Nos. <br>2000A,FP,50kA.Microprocessor based Buscoupler- 1 no<br>2000A 433V, 50kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 4 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 4 Nos <br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 2 set<br>Outgoings<br>1250A 50 kA FP ACB EDO Microprocessor based - 1 Nos. <br>800A 50 kA FP ACB EDO Microprocessor based - 1 Nos. <br>630A 36kA TP Microprocessor Based MCCB - 7 nos.<br>500A 36kA TP Microprocessor Based MCCB - 4 nos.<br>500A TPN Isolator - 1 no | 1 | each | |
| 782 | 21.18 | od300290/2020_2021 : DG SYNCHRONISATION PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required forcomplete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>DG Incomer 1 & 2 - 1000A 50 kA TP ACB EDO Microprocessor based with overload and E/F release and stand by low set earth fault relay using CT in neutral earthing strip - 2 Nos. <br>200A Neutral Contactor - 2 nos.<br>2000A,FP,50kA.Microprocessor based Buscoupler- 1 no<br>2000A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Supply, erection, testing & commisioning of PLC for synchronising of 2 nos DG set with PLC(Seimens make) and Synchronization Relay Deif - 2 nos, SMPS - 1 no ,AUX contactor or Relay -1no,Relay Module-2nos ,DIN Rail-6nos,Selector Switch-2Nos,Push Buttons,Terminals,Indication lamp,Legs,End plate,Stopper,1.5Feule-,Screws,Neutral links,2.5Sqmm wire interconnections,1.5Sqmm wire interconnections, cable ties,Tie mount,Cable tie 150 as required and all other accesories and componets as required for complete installation and as instructed by engineer in charge/consultant.<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 2 Nos <br>Reverse Power Relay - 2 nos.<br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 2 set<br>Outgoings<br>1000A 50 kA FP ACB EDO Microprocessor based - 2 Nos. <br>800A 50 kA FP ACB EDO Microprocessor based - 2 Nos. | 1 | each | |
| 783 | 21.19 | od300291/2020_2021 : COMMON SERVICE PANEL<br>Supplying, installation, testing & commissioning of cubical type, dustand vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350μ sec) for each Line to Neutral & 100 KA(10/350μ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer -<br>630A 36kA FP Microprocessor Based MCCB - 1 no.<br>200A 36kA FPthermal magnetic based MCCB - 1 no. (For solar incomer)<br>630A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Surge Protection Device Class B & Class C/ Class 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>320A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>250A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>200A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>160A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>125A 25kA TP Thermal Magnetic Based MCCB - 2 nos.<br>100A 25kA TP Thermal Magnetic Based MCCB - 4 no | 1 | each | |
| 784 | 21.2 | od300292/2020_2021 : PLUMBING PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include pluggable type surge arrester Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters to connect between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, . Lightning Impulse Current - 12.5 kA (10/350μ sec) for Line to Neutral & 25 kA(10/350μ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20μ sec) for Line to Neutral & 40 kA(8/20μ sec) for Neutral to Earth. Voltage protection level <1.5KV (L to N) & 1.5KV (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Incomer -<br>200A FP Isolator - 1 no.<br>200A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Outgoings<br>63A TP MCB D curve- 1 no.<br>32A TP MCB D curve - 13 nos.<br>Supply, Installation, erection, testing and commissioning <br> | 1 | each | |
| 785 | 21.21 | od300293/2020_2021 : STREET LIGHTING PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zincplated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of<br>Panels :- Rittal (Assembled by Rittal Authorised Panel Integrator).<br>Incomer <br>40A FP Isolator - 1No.<br>40A 433V, 16kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>40A FP Contactor - 1 no.<br>Astronomical time switch for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay - 1 nos.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>25A TP MCB - 3 nos.<br>25A DP MCB - 1 no.<br> | 1 | each | |
| 786 | 21.22 | od300294/2020_2021 : MEDICAL GAS PANEL<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80- 120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include pluggable type surge arrester Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters to connect between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, . Lightning Impulse Current - 12.5 kA (10/350μ sec) for Line to Neutral & 25kA(10/350μ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20μ sec) for Line to Neutral & 40 kA(8/20μ sec) for Neutral to Earth. Voltage protection level <1.5KV (L to N) & 1.5KV (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Incomer -<br>315A FP Isolator - 1 no.<br>315A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multi function digital LED meter with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, kW, frequency, kVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, THD etc. - 1 No <br>Outgoings<br>160A 25kA TP Thermal Magnetic Based MCCB - 1 no.<br>63A 25kA TP Thermal Magnetic Based MCCB - 7 nos.<br> | 1 | each | |
| 787 | 21.23 | od300460/2020_2021 : Supply of LED bulkhead luminaire that fits seamlessly in a variety of applicatications, consuming a power of 6 W , lumen output greater than 700 lumens with a system efficacy > 110 lm/W. The luminaire shall housing shall be made of High Pressure diecast aluminum with a UV stablised polycarbonate diffuser, IP 66 and IK 09 protection. The luminaire shall have a power factor > 0.9 and shall have 50,000 burning hours as per L70 criteria. The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted. <br>(Make : Philips WT202W LED6S CW PSU S1 PC or equivalent) | 49 | each | |
| 788 | 21.24 | MISCELLANEOUS CIVIL ITEMS | |||
| 789 | 21.25 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 600 | kg | |
| 790 | 21.26 | 10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. | 221 | each | |
| 791 | 21.27 | 10.18 : Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing . | 221 | each | |
| 792 | 21.28 | 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 0.1 | cum | |
| 793 | 21.29 | MCB, SWITCHGEARS & DBs | |||
| 794 | 21.3 | od305471/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) <br>8 way (4 + 24), Double door | 3 | each | |
| 795 | 21.31 | od305488/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>12 way (4 + 36), Double door | 4 | each | |
| 796 | 21.32 | HT PART, DG SET & ALLIED WORKS | |||
| 797 | 21.33 | od305559/2019_2020 : HT PANEL BOARD (TRAUMA BLOCK)<br>Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number 630A VCB as incomer and three numbers of 630A VCB as outgoings as per the specification details below. Panel shall be factory fitted type with type testing certificates as per IEC 62271 Part 100(for VCB) & Part 200(for enclosure). Panel shall be supplied with minimum two years warranty against manufacturing / maintenance defects/ damages by manufacturer. No excemption in any components will be accepted for warranty exemptions. All CTs & PTs shall be type tested as per standards and certificates shall be produced before supply of the panel test shall include but not limited to polarity test, high voltage power-frequency one minute withstand test, induced over voltage test, partial discharge measurement, accuracy test, intertum insultation test, dimension check, ratio and phase angle error test etc. Insulation resistance test and fuctional testes of panel and VCB shall be produced. Fuctuional tests shall include but not be limited to mechanical operation test for opening and closing under no load condition, master trip relay and auxilary relays, over current and earth fault relay test, breaker rack IN and Rack OUT , MFM, voltmeter, ammeter and all other meters programmed and checked, motor charging etc. Panel shall include all relays and tripping mechanisms and accesories as required as per KSEI standards. Panel shall have cable entry on top side for both incoming and outgoing cables. HT panel board shall be manufactured with provision for installingTOD meter in incomer side as per schematic layout with necessary CTs and all accesories as required.<br>Incoming:<br>1nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection & metering(Class0.2 S) .<br>Out goings :<br>3 nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class<br>Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL :0.2 must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures andpowder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. <br>The panel shall include auxillary DC power supply unit, 24V, with required Ah capacity battery power pack including all accesories required for complete backup of all indicators, mechanisam and operating system in the panel with stationary type, high discharge perfomance,Valve Regulated Lead Acid (VRLA) sealed maintenance free battery, battery charger including all other accessories like battery rack, interconnecting cables etc as required The power pack and accesories shall be placed in the panel itself. | 1 | each | |
| 798 | 21.34 | od310474/2019_2020 : 650kVA DIESEL GENERATOR<br>Supply, installation, testing and commissioning of radiator cooled 3 phase, 415V±0.1%, 0.8pf 50hz. prime rated 3B DG set of the rating 650 kVA comprising of diesel engine, alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG's. The battery charger shall be included by the same manufacturer of auxillary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge perfomance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required. The Generator set shall have a integral type acoustic enclosure as per latest CPCB II norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with EURO-II specifications. <br>"The generator set shall be supplied in accordance but not limited with the following codes and standards - ISO 8528, ISO 3046, ISO 9001, BIS, CIEG, NEMA MG-1, State electricity board regulation, BSI, state pollution control board, central pollution control board, Indian electricity rules 1956, CPWD, IEC, IEE standards, Engine conform to BS 5514/IS: 10000 and the ISO 8528, Alternator in accordance with IS: 4722/BS: 2613/IEC-34(Part-1), NEMA MG1, IEEE, ANSI, Specification for AC Generators driven by Reciprocating Engine: IS 13364(1-2)/1992, • Performance class of the DG SET Shall be CLASS G3 as per ISO8528 PART-1. <br>"<br>The DG sets performance class shall be suitable to power highly non - linear loads and subsequent certification has to be submitted. The supplier shall warrant the equipment to be free from defects in material and workmanship for 24 months from the date of commisioning. The Engine shall suitable to drive alternator of base load application 24/7 operation. Engine/generator sets shall meet performance class of ISO8528 Part-1 & IEEE emergency power requirement to start and be on line within 10 seconds of onset of failure.<br>"Diesel Engine of required bhp, stationary type and four stroke with Inline cylinder arrangement shall be complete with integral air intake through suitable air filters and exhaust system, speed regulation system, fuel injection system, lube oil system, cooling water system, silencers, self-contained piping, instruments, mounted on anti-vibration mounts, turbo charged, multi- cylinder, 4-stroke, with continous power output at 1,500 r.p.m battery started .The engine shall have 10% overload capacity for one hour in every 12 hours of operation as per ISO. Fuel system shall comprise of fuel pump, fuel injectors, fuel filter, fuel hoses, lube oil pump, lube oil priming pump, lube oil filter, bypass filter etc. The DG set shall be supplied with 990L fuel tank within the canopy itself. In addition to this 2 nos 990L capacity day tanks shall be provided in a closed enclosure. The capacity of the fuel tank supplied has to be capable for 8 Hrs continuous operations @ 80% load. Supply shall include • Fuel tank pipe from diesel engine to day tank and return, Refueling and drainage plugs, welding sleeves and fixing material.<br>"<br>Following protection/warning shall be provided but not limited to with the DG set, Engine over Speed Shutdown, Low Lube Oil Pressure Warning /Shutdown, High Coolant Temperature Warning / Shutdown, Low Coolant Level Warning / Shutdown, Low Coolant Temperature Warning, Low And High Battery Voltage Warning, Weak Battery Warning, Dead Battery Shutdown, Over Crank Shutdown, Fail To Crank Shutdown<br>The governor shall be Electronic type confirming complete with Display unit and shall be a self-contained unit capable of monitoring speed.The engine/generator sets shall be provided with electronic governors suitable for unattended automatic paralleling and load sharing. The steady state frequency regulation shall less than be +/_ 0.25 percent.They shall be capable of sharing load within 5 percent when paralleled with similarly equipped engines. The engine speed shall be so maintained that frequency variation at constant load including no load shall remain within band of 0.5% of rated frequency<br>Each engine shall be provided with residential type silencers so as to limit the sound level from the DG set. The engine and direct coupled alternators shall be rigidly secured to common rigid base frames fabricated from MS sections. The DG set shall be placed on concrete block with anti-vibration mountings. The engine air intake shall be fitted with dry type air cleaner with vacuum indicator facilitating change of air filter. Filter for fuel and lubricating oil systems shall be of replaceable paper element type. There shall be no moving part requiring lubrication by hand prior to the starting of the engine or while in operation. It shall be so designed that when the engine starts after a long shut down lubrication failure does not occur. Necessary priming pump for the lub oil circuit shall be installed to keep bearings primed. Speed control shall be so arranged that 12-13% increase over normal rated speed shall cut off fuel supply, thus stopping the engine. The DG sets shall be complete with all equipments, indications and controls required for fully reliable and safe operation of the DG sets whether specifically stated in these specifications or not. It is essential that the operation of all protection equipments be completely reliable in all respects.<br>"The DG Set shall be supplied with micro-processor based generator monitoring, metering & protection feature with display viz Analogue & Digital AC output metering, Battery monitoring system to sense and warn against a weak battery condition.,Digital alarm & status message display, Overload, Overcurrent, Over voltage, Under voltage, Over frequency, Under frequency, Reverse Power Relay, Restricted Earth Fault<br>"<br>Synchronous alternator of suitable capacity to generate as stated above output at alternator terminal at 415 V, 50 Hz, 3 Phase, 4 Wire, 0.8 pf (lag) 1500 RPM and in accordance with BS:2613 / IS:4722/IEC-34(Part-I) shall be of totally enclosed or screen protected dip proof and self-air-cooled type driven by the Diesel Engine. Generator shall be supplied along with its excitation system. All routine test as per IS/BS codes shall be conducted on alternator. The engine and alternator supplied shall be duly tested and supported by the test certificates of the respective manufacturer. Also to submit type test certificates for DG Set.<br>Generator set with inclusive of fly wheel, flexible coupling, air cleaner, corrosion resistor, fan with guard, fuel pump, turbocharged exhaust manifold, SS exhaust flexible connections, fuel filter, lube oil filter and by-pass, electrical starting system with starter, 24V battery with regulator, instrument panel, rpm indicator, residential silencer, heavy duty air cleaner, lube oil/coolant heater with thermostatic switch, space heater for alternator, audio/visual annunciation for faults. With microprocessor based controller. Silencer shall be suitably optimized to reduce noise.<br>Controller shall be equiped with auto, manual, start, stop, fault reset and lamp test/panel lamp switches with alpha-numeric displays and push buttons, indications for genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode, stop etc with sync check. For alternator - line to neutral and line to line volts indication, current, frequency, kW, kVAr, power factor kVA and for engine following indications - DC voltage, engine speed, lube oil pressure, coolant temperature, coolant low level, with start/stop attempts, runnings hours, kW hours, load profile, fault history, datta logging etc and all data shall be recoreded. Generator shall be suitable for synchronisation with other DG sets and all components required for this shall be included in the scope of work. For 650 kVA DG:- Floor mounted dust and vermin proof, outdoor type standard controlpanel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number Microprocessor based ACB EDO rating of 1000A, 4pole, 50 kA breaking capacity, thermal over load, voltage controlled O/C relay, over voltage, under voltage, negative sequence relay, voltmeter with selector switch, 3 ammeters of 0-1000A range, frequency meter, kW, pf, electronic energy meter with CTs and indicating lamps with fuse and switch control etc. as complete with necessary control wiring interconnections etc. <br>(Energy meter& CTs shall be tested and certificate shall be obtained from electrical inspectorate lab) Following sanction may be obtained by the contractor,<br>(i) Sanctions from Municipality/ Corporation<br>(ii) Sanction from Pollution control Board<br>(ii) Sanction from electrical inspectorate<br>Outdoor acoustic enclosure for the DG set. The sound level shall be brought down to 70DB+/-5 with at a distance of 1m (as per CPCB norms the sound level shall be 75dB at a distance of 1m from the silencer at the top of the enclosure).Accoustic enclosure shall be provided as per manufacturer standards confirmining to CPWD standards mentioned.Acoustic insulation material shall be mineral wool/ resin bounded fibre glass Doors shall be openable on either side. Exhaust fan of sufficient capacity tube lights etc. shall be provided inside the enclosure. Sufficient fresh air intake and hot air outlet with splitters to be arranged so that the temperature inside should not increase to 5 degree above ambient temperature. (The enclosure shall bare certificate from the generator manufacturer conforming the CPCB II norms and serial numbers of the test certificate). Exhaust pipe inside the enclosure upto and including silencer shall be enclosed with Al cladding over thermal insulation. including first filling of oil and lube for commissioning of the DG set. The stanadrad control panel and its enclosure shall be of the same make as specified for all MV panels in the tender. Push button for emergency OFF shall be placed outside in seperate enclosure, painted in red covered by glass. The DG set shall be with necessary communication module for integrating with IBMS using Modbus/BackNet protocol <br>Supply, Installation, testing and commisioning<br> | 1 | each | |
| 799 | 21.35 | od305619/2019_2020 : Laying of following 11 kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in separate existing cable tray/ on surface using factory made clamps and the spacing between clamps will not exceed 60 cm.<br>Above 120 sq. mm and up to 400 sq. mm | 20 | metre | |
| 800 | 21.36 | od305620/2019_2020 : HT CABLE SUPPLY & LAYING<br>Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. <br>3cx300sq.mm XLPE Cable | 202 | metre | |
| 801 | 21.37 | od305621/2019_2020 : 1000kVA 11kV/433V Cast Resin (Dry type) Laser Scribed K4 rated Transformer<br>Supply, installation, testing & commissioning of 1000kVA 11kV/433V indoor cast resin dry type laser scribed core transformer (copper double wound) with OLTC having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping +5% to -15% in steps of 1.25% changeable by OLTC, AVR & RTCC, including separate winding temperature indicator for each phase and core in the Transformer. Transformer should have cable end box on HV side suitable for 3Cx300 sq.mm XLPE cable and suitable end box on LV side for connecting 1600A Al BBT, with all accessories, complete as required as per State electricity board, ECBC, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/85 with latest amendment etc complete. Transformer shall be CPRI tested and test reports to be furnished as per IS 11171/85(Reaffirmed 2016). Transformer and all accesories included shall be supplied with minimum two years warranty against manufacturing /defects/ damages. No excemption in any components will be accepted for warranty exemptions. Insulation class of transformer shall be class H with maximum winding temperature and hot spot temperature as per IS. Tolerances, voltage regulation and all losses, impedance and other parameter values shall be as per IS tolerance and test certificates of the same to be provided. Cable entry & bus bar outgoing for transformer shall be top entry. Colling shall be ANAF. Transformer shall be rated K-4 (k factor for harmonics effect heating reduction design class). Harmonics mitigating suppresors shall also be considered in the transformer. K-factor of the transformer shall be inscribed in the nameplate of the transformer. Impulse voltage withstand at HV side and power frequency withstand voltage at HV side and LV side shall be as per standards and test certificates for the same shall be furnished. Transformer enclosure shall be powder coated after 7 tank treatment. All routine tests as per standards to be provided before dispatch of the transformers alongwith which load testing shall be conducted for minimum 4 hours. All test results should be found satisfactory by the Client representative before dispatch. Push button for emergency OFF shall be placed outside in seperate enclosure, painted in red covered by glass.<br> | 1 | each | |
| 802 | 21.38 | od305661/2019_2020 : EXHAUST PIPES<br>Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>250mm dia | 15 | metre | |
| 803 | 21.39 | od305671/2019_2020 : EXHAUST PIPES<br>Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>300mm dia | 10 | metre | |
| 804 | 21.4 | od305744/2019_2020 : Supply & providing thermal insulation for silencer with inner glass wool and providing aluminium cladding for 650 kVA DG set exhaust pipe length as per standards. | 1 | set | |
| 805 | 21.41 | od305748/2019_2020 : Supplying and fixing vertical 2 inch GI Pipe 4-6 mtr height and truss work using 3inch X 1.5Inch size pipe also fixing the purling over the truss work( Size of Purlin- 1.5Inch X 0.75 Inch ) and covered with 0.35mm traffod sheet including two coat of paint over two layer of metal Primer | 100 | sqm | |
| 806 | 21.42 | od317450/2019_2020 : Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.<br> | 25 | metre | |
| 807 | 21.43 | CABLES AND END TERMINATION | |||
| 808 | 21.44 | od305746/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx400sq.mm Al Cable | 1494 | metre | |
| 809 | 21.45 | od305751/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx150sq.mm Al Cable | 78 | metre | |
| 810 | 21.46 | od305752/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx185sq.mm Al Cable | 84 | metre | |
| 811 | 21.47 | od305753/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx240sq.mm Al Cable | 360 | metre | |
| 812 | 21.48 | od305754/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx300sq.mm Al Cable | 420 | metre | |
| 813 | 21.49 | od305757/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx95sq.mm Al Cable | 360 | metre | |
| 814 | 21.5 | od305758/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx120sq.mm Al Cable | 174 | metre | |
| 815 | 21.51 | od305770/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx35sq.mm Al Cable | 24 | metre | |
| 816 | 21.52 | od310636/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx35sq.mm Al Cable | 618 | metre | |
| 817 | 21.53 | od310523/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx16sq.mm Al Cable | 60 | metre | |
| 818 | 21.54 | od310525/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx70sq.mm Al Cable | 96 | metre | |
| 819 | 21.55 | od305787/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx10sq.mm Al Cable | 978 | metre | |
| 820 | 21.56 | od305789/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx16sq.mm Al Cable | 755 | metre | |
| 821 | 21.57 | od305790/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx25sq.mm Al Cable | 1 | metre | |
| 822 | 21.58 | od305792/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx50sq.mm Al Cable | 348 | metre | |
| 823 | 21.59 | od305805/2019_2020 : Supply of the following size Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire or galvanised steel strip), extruded PVC Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988<br>12x2.5sq.mm Cu Control Cable | 204 | metre | |
| 824 | 21.6 | od305806/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx10sq.mm Al Cable | 108 | metre | |
| 825 | 21.61 | od305807/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx4sq.mm Al Cable | 307 | metre | |
| 826 | 21.62 | od309149/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx6sq.mm Al Cable | 2382 | metre | |
| 827 | 21.63 | od309150/2019_2020 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx10sq.mm Al Cable | 368 | metre | |
| 828 | 21.64 | od305818/2019_2020 : Supply and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1Cx95sq.mm Copper Flexible Cable | 180 | metre | |
| 829 | 21.65 | od305819/2019_2020 : Supply of the following size Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire or galvanised steel strip), extruded PVC Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988<br>2x2.5sq.mm Cu Control Cable | 264 | metre | |
| 830 | 21.66 | od306336/2019_2020 : Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>12Cx2.5 sq.mm Cu Control Cable | 2 | each | |
| 831 | 21.67 | od308770/2019_2020 : Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>2Cx2.5 sq.mm Cu Control Cable | 24 | each | |
| 832 | 21.68 | od308771/2019_2020 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>95sq.mm | 60 | each | |
| 833 | 21.69 | od308772/2019_2020 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx4sq.mm Al Cable | 20 | each | |
| 834 | 21.7 | od308773/2019_2020 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx6sq.mm Al Cable | 96 | each | |
| 835 | 21.71 | od129217/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2x6sq.mm Al Cable | 120 | metre | |
| 836 | 21.72 | od129218/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3x6sq.mm Al Cable | 120 | metre | |
| 837 | 21.73 | od129219/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx185sq.mm Cu Cable | 24 | metre | |
| 838 | 21.74 | LIGHT AND FAN FIXTURES | |||
| 839 | 21.75 | od306337/2019_2020 : Supply of heavy duty exhaust fan of 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, TurboForce SP or equivalent) | 1 | each | |
| 840 | 21.76 | od310367/2019_2020 : Supply & installation of wall fan of 450 mm sweep Havells Airboll Hi-speed or equivalent) including all accessories as required for complete installation. | 29 | each | |
| 841 | 21.77 | od306338/2019_2020 : Supply of exhaust fan of 250mm sweep in the existing opening, as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, Ventil Air DX White or equivalent) | 1 | each | |
| 842 | 21.78 | od306340/2019_2020 : GI aesthetically good looking tubular pole 3m height, hot dip galvanised for mounting of Post top luminiare applied with primer and paint | 2 | each | |
| 843 | 21.79 | od306341/2019_2020 : Supply ,installation, testing and commissioning of LED Post Top with a system lumen output of ≥ 2300 lumens .The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI > 70. The luminaire shall meet IP65 with THD < 20% and PF > 0.9. The luminaire shall have closed diffused optics with polycarbonate diffuser board. The total power consumption should not exceed 27W (including driver). The luminaire shall be made up of aluminium die cast housing with polycarboate cover. Luminaire should be with minimum system efficacy of ≥ 85Lumen/Watt. Luminaire should withstand THD less than 10% and should have power factor > 0.90. Driver efficiency should be 85% . Luminaire should comply with all the required IEC standards and should operate in a voltage range of 220-240 volts AC. The luminaire shall be dark grey in color. The LEDs used shall be of high power LEDs. The driver shall be potted type. The luminaire shall be BIS tested and approved / registered mentioning 'R' number and test certificates of LM79 and LM80 reports shall be submitted, including all accesories as required for complete installation. (Make : Philips BGP161 LED23WW PSU or equivalent) | 4 | each | |
| 844 | 21.8 | od306342/2019_2020 : Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include two arms for fixing including two numbers LED street light luminaire power consumption 60 W , luminaire output of 6800 lumens with luminaire efficacy > 120 lm/W. The luminaire shall have a finless design and shall have pressure diecast housing and polycorbonate cover with high impact resistance confirming IP65 and IK07. The luminaire shall have an integrated optics to provide uniform light distribution on the street. The luminaire shall have a wide operating voltage in the range of 100 - 270 V, power factor >0.95, CCT 5700 K, CRI >70, internal surge protection 4 kV. The luminaire shall have 50,000 burning hours as per L70B50 criteria. The luminaire shall have high voltage cut off and auto restart option and 440 V stress voltage protection. The luminaire shall have Class -1 Electrical safety and be BIS tested and approved and test certificates of LM79 and LM80 reports shall be submitted (Make Light fixture : Philips BRP062 LED 68 CW SLC S1 or equivalent) including all accesories required for complete installation. (Make Pole - Bajaj / Lighting Technologies /Valmount ) | 12 | each | |
| 845 | 21.81 | od306343/2019_2020 : Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include one arm for fixing including LED street light luminaire power consumption 60 W , luminaire output of 6800 lumens with luminaire efficacy > 120 lm/W. The luminaire shall have a finless design and shall have pressure diecast housing and polycorbonate cover with high impact resistance confirming IP65 and IK07. The luminaire shall have an integrated optics to provide uniform light distribution on the street. The luminaire shall have a wide operating voltage in the range of 100 - 270 V, power factor >0.95, CCT 5700 K, CRI >70, internal surge protection 4 kV. The luminaire shall have 50,000 burning hours as per L70B50 criteria. The luminaire shall have high voltage cut off and auto restart option and 440 V stress voltage protection. The luminaire shall have Class -1 Electrical safety and be BIS tested and approved and test certificates of LM79 and LM80 reports shall be submitted (Make Light fixture : Philips BRP062 LED 68 CW SLC S1 or equivalent) including all accesories required for complete installation. (Make Pole - Bajaj / Lighting Technologies /Valmount ) | 3 | each | |
| 846 | 21.82 | od306345/2019_2020 : Supply of 28W LED 2x2 indoor luminaire suitable for surface mount application, pressure die cast aluminium alloy housing with corrosion resistance powder coating using nono technology. Injection moulded UV stabilized diffuser of optimum light transmission, high lumen package with frame for gypsum ceiling if required and all accesories as required for complete installation (Make - Lighting Technologies - Sparkle Ultra Surface 28W 5700K or equivalent) | 78 | each | |
| 847 | 21.83 | od306346/2019_2020 : Supply of 30W LED 2x2 indoor luminaire suitable for recess mount application, CRCA housing with corrosion resistance powder coating using nono technology. UV stabilized diffuser of optimum light transmission, high lumen package with frame for gypsum ceiling if required and all accesories as required for complete installation (Make - Lighting Technologies - Fulllit CR 30W 5700K or equivalent) | 262 | each | |
| 848 | 21.84 | od310368/2019_2020 : Supply of 18W indoor luminaire suitable for surface mount application, pressure die cast aluminium alloy housing with corrosion resistance powder coating using nono technology. Injection moulded UV stabilized diffuser of optimum light transmission and all accesories as required for complete installation (Make - Lighting Technologies - Lunar Max 18W 5700K or equivalent) | 44 | each | |
| 849 | 21.85 | od306348/2019_2020 : Supply of LED Recess mounted luminaire (2x2), with a nominal system lumen output of 3600 lumens and a minimum system efficacy of 125 lm/W. The luminaire wattage shall not exceed 29 W. The luminaire should have a color temperature of 6500K and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. The luminaire must be flicker free with ripple content less than 5 %. The luminaire housing should be made of powder coated metallic CRCA with high efficiency opal diffuser. The luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The luminaire must have a life class of 50,000 burning hours as per L70B50 criteria, 4 kV surge protection. The luminaire shall be EMI/ EMC compliant.The luminaire and driver shall be BIS aprroved test certificates of LM79 and LM80 reports shall be submitted | 261 | each | |
| 850 | 21.86 | od306349/2019_2020 : Supply of LED Recess mounted glare free luminaire (2x2) with a nominal system lumen output of 3600 lumens and a minimum system efficacy of 110 lm/W. The luminaire wattage shall not exceed 34 W. The luminaire should have a color temperature of 6500K and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. The luminaire must be flicker free with ripple content less than 5 %. The luminaire housing should be made of powder coated metallic CRCA with high efficiency prismatic diffuser so that the UGR should be less than 19. The luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The luminaire must have a life class of 50,000 burning hours as per L70B50 criteria, 4 kV surge protection. The luminaire shall be EMI/ EMC compliant.The luminaire and driver shall be BIS and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips RC380B LED36S-6500 G5 L60W60 PSU OD SG or equivalent) | 149 | each | |
| 851 | 21.87 | od306350/2019_2020 : Supply of LED recess mounted bottom opening clean room fixture with a power consumption of 36 W and system efficacy greater than 90 lm/W. The CRI should be >80 , CCT-6500, SDCM <5 and pf >0.9 . The luminaire housing must be made of white poweder coated CRCA steel with clear acrylic diffuser. The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips CR652B LED33S CR CW PSU or equivalent) | 42 | each | |
| 852 | 21.88 | od306351/2019_2020 : Supply of 4 feet surface mounted battern type luminaire with a power consumption not more than 34 W, luminaire lumen output of 4000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted<br>(Make: Philips BN308 LED40S 6500 L120 PSU WH or equivalent ) | 23 | each | |
| 853 | 21.89 | od306352/2019_2020 : Supply of 4 feet surface mounted battern type luminaire with a power consumption not more than 17 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports from NABL accredited labs.(Make: Philips BN308 LED20S 6500 L120 PSU WH or equivalent) | 161 | each | |
| 854 | 21.9 | od306353/2019_2020 : Supply of recess mounted LED downlighter with a circular form factor with a power consumption of 18 W and a system level lumen output of 2000 lumens and a system level luminous efficacy >110 lm /W. The luminaire shall have a pressure die cast aluminium housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor >0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted | 94 | each | |
| 855 | 21.91 | od306354/2019_2020 : Supply of recess mounted LED downlighter with a circular form factor with a power consumption of 13.5 W and a system level lumen output of 1500 lumens and a system level luminous efficacy >110 lm /W. The luminaire shall have a pressure die cast aluminium housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor >0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted(Make: Philips DN296B LED15S 6500 PSU or equivalent) | 180 | each | |
| 856 | 21.92 | od306355/2019_2020 : Supply of LED round designer downlighter with a nominal system lumen output of 1600 lumens and a minimum system efficacy >100 lm/W. The luminaire shall have a rated system lifetime of 30,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. The luminaire housing should made of plastic with a polycarbonate reflector and a high quality diffuser. The total power consumption should not exceed 15W (including driver).(Make : Philips Sleek surface SM251C LED16S PSU or equivalent) | 45 | each | |
| 857 | 21.93 | od129239/2020_2021 : Supply, fixing, testing and commissioning of 0.5 M arm having dia max 43mm for fixing exterior light fixture of approved make (Model No: Bajaj BOP - 1030 or equivalent) designed to withstand the maximum wind speed as per IS 875. The arms shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The arms shall be capable for fixing one number Supply of 25 W LED street light luminaire with system efficacy greater than 120 lm/W and system lumen output greater than 2800 lumens, CRI >70 , CCT-5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis Min 25W 5700K LED pole mounted fixture or equivalent) including all accesories required for complete installation as instructed by engineer in charge/consultant. <br> | 14 | each | |
| 858 | 21.94 | FLEXIBLE PVC CONDUIT | |||
| 859 | 21.95 | od306436/2019_2020 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>25mm dia | 155 | metre | |
| 860 | 21.96 | od306437/2019_2020 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>20mm dia | 974 | metre | |
| 861 | 21.97 | RCBO | |||
| 862 | 21.98 | od306450/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>63A 100 mA DP RCBO | 15 | each | |
| 863 | 21.99 | od306451/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>40A 100 mA DP RCBO | 21 | each | |
| 864 | 22 | od306452/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>32A 100 mA DP RCBO | 31 | each | |
| 865 | 22.01 | od306453/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>32A 30 mA DP RCBO | 51 | each | |
| 866 | 22.02 | od306454/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>25A 30mA DP RCBO | 1 | each | |
| 867 | 22.03 | od307031/2019_2020 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>63A 100mA FP RCBO | 7 | each | |
| 868 | 22.04 | WIRING FOR STAIRCASE LIGHT POINT | |||
| 869 | 22.05 | od310889/2019_2020 : Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)<br>One light point controlled by one way switch | 3 | point | |
| 870 | 22.06 | od310890/2019_2020 : Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)<br>Loop wiring for Light point | 26 | point | |
| 871 | 22.07 | ISOLATOR WITH ENCLOSURE | |||
| 872 | 22.08 | od306956/2019_2020 : Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>63A FP Isolator with enclosure | 5 | each | |
| 873 | 22.09 | od306957/2019_2020 : Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>160A FP Isolator with enclosure | 1 | each | |
| 874 | 22.1 | od306958/2019_2020 : Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>200A FP Isolator with enclosure | 3 | each | |
| 875 | 22.11 | od306959/2019_2020 : Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>315A FP Isolator with enclosure | 1 | each | |
| 876 | 22.12 | od307136/2019_2020 : Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A FP Isolator with enclosure | 45 | each | |
| 877 | 22.13 | POP UP BOX | |||
| 878 | 22.14 | od311017/2019_2020 : Supply, Fixing, testing and commisisoning of 4 module Matt black finish pop up box with slim design for perfect integration into furniture equipped with one number 6A socket and one number CAT 6 data socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. | 1 | each | |
| 879 | 22.15 | od311018/2019_2020 : Supply, Fixing, testing and commisisoning of 8(2x4) module Matt black finish pop up box with slim design for perfect integration into furniture equipped with 2 number 6A socket and 1 number CAT 6 data socket & provision for fixing and including one number AV/HDMI socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. | 1 | each | |
| 880 | 22.16 | INDUSTRIAL SOCKET | |||
| 881 | 22.17 | od307224/2019_2020 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.<br>32A 5P+E | 1 | each | |
| 882 | 22.18 | od307225/2019_2020 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.<br>32A 2P+E | 1 | each | |
| 883 | 22.19 | od307226/2019_2020 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.<br>20A 2P+E | 43 | each | |
| 884 | 22.2 | CHANGE OVER SWITCH | |||
| 885 | 22.21 | od311321/2019_2020 : Supply, installation, testing and commisioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation.<br>32/40A, 415V, FP COS | 3 | each | |
| 886 | 22.22 | MODULAR SWITCH AND SOCKET | |||
| 887 | 22.23 | od309109/2019_2020 : MODULAR SWITCH & SOCKET<br>Supply and fixing of modular 25A power switch with indication placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation. | 1 | each | |
| 888 | 22.24 | od309110/2019_2020 : MODULAR SWITCH & SOCKET<br>Supply and fixing of modular 25A power socket placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation. | 1 | each | |
| 889 | 22.25 | GI BOX | |||
| 890 | 22.26 | od307795/2019_2020 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>8 Module | 214 | each | |
| 891 | 22.27 | od307796/2019_2020 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>6 Module | 183 | each | |
| 892 | 22.28 | od307797/2019_2020 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>4 Module | 76 | each | |
| 893 | 22.29 | od307798/2019_2020 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>3 Module | 5 | each | |
| 894 | 22.3 | od307799/2019_2020 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>1/2 Module | 5 | each | |
| 895 | 22.31 | PVC RECESS BOX | |||
| 896 | 22.32 | od307983/2019_2020 : Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge<br>6 Module | 21 | each | |
| 897 | 22.33 | od307984/2019_2020 : Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge<br>4 Module | 5 | each | |
| 898 | 22.34 | od307985/2019_2020 : Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge<br>3 Module | 10 | each | |
| 899 | 22.35 | od308009/2019_2020 : Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge<br>4 module | 56 | each | |
| 900 | 22.36 | od308010/2019_2020 : Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge<br>3 module | 5 | each | |
| 901 | 22.37 | od308011/2019_2020 : Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge<br>1/2 module | 5 | each | |
| 902 | 22.38 | MCCB | |||
| 903 | 22.39 | od308097/2019_2020 : Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>125 Amp 16kA FP MCCB with Thermal-Magnetic Release | 6 | each | |
| 904 | 22.4 | od308271/2019_2020 : Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>100 Amp 16kA FP MCCB with Thermal-Magnetic Release | 3 | each | |
| 905 | 22.41 | ISOLATOR FOR DB | |||
| 906 | 22.42 | od308146/2019_2020 : Supply, fixing, testing and commisioning of following rating and pole Isolator in existing Seven Segment Distribution Board, tier DBs and Vertical distribution board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>32A FP Isolator | 26 | each | |
| 907 | 22.43 | TPN SEVEN SEGMENT DB | |||
| 908 | 22.44 | od308153/2019_2020 : Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>12 way Seven Segment DB | 10 | each | |
| 909 | 22.45 | od308154/2019_2020 : Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>8 way Seven Segment DB | 5 | each | |
| 910 | 22.46 | od308155/2019_2020 : Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>6 way Seven Segment DB | 14 | each | |
| 911 | 22.47 | FLEXI/ROW PPI DB | |||
| 912 | 22.48 | od308304/2019_2020 : Supplying,fixing, testing and commisioning following way, vertical type three pole and neutral, sheet steel, MCB flexi row distribution board, conforming to IEC 61439-1&3, IS 8623-1, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). DB shall be IP 43 rated double door with IK 09 protection fabricated with CRCA sheet steel, RAL 9003, powder coated with neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, cable ties, blanking plates and circuit identification labels with provision for mounting modular devices as per requirement (But without MCB/RCCB/ Isolator). Incomer shall be 14 modules with provision for adding direct multifunction meter for EMS integration and surge arrestors. (DBs for OT & ICU)<br>4 Row 56 Module | 8 | each | |
| 913 | 22.49 | TPN VDB | |||
| 914 | 22.5 | od308311/2019_2020 : Supply, installation, testing and commisioning of vertical TPN DB conforming to IS 8623-1 &, IEC 61439-1 & 3, double door made of CRCA sheet steel, RAL 9003,powder coated enclosure, with insulated vertical phase bus-bars, neutral bars with shrouds, earth bars,sticking saddles, cement spill protector, color coded interconnecting wire set including all interconnections, with provision for MCCB as incomer and MCB's as outgoings,IP 43, IK09, including all connections, making good all damages made during installation as instructed by engineer in charge/consultant.<br>6 way VDB | 2 | each | |
| 915 | 22.51 | MCB | |||
| 916 | 22.52 | od308338/2019_2020 : Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant.<br>63A TP MCB | 5 | each | |
| 917 | 22.53 | od308339/2019_2020 : Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant.<br>40A TP MCB | 7 | each | |
| 918 | 22.54 | SURGE ARRESTER FOR SMDB | |||
| 919 | 22.55 | od308348/2019_2020 : Supply, installation testing & commisisoning of pluggable type surge arrester to be fixed in the existing bottom module of loadbank, DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 260KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV withstand for 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25kA/50 kA . Back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <100 nano sec . and all accesories as required for complete installation of the same, including all connections using Cu flexible cable between arrestor and incomer etc complete as required. (Cabling distance between arrestor and incomer shall be kept to minimum as per manufacturer standard)<br>Supply & Installation<br> | 3 | each | |
| 920 | 22.56 | SURGE ARRESTOR FOR DBs & VDBs | |||
| 921 | 22.57 | od308352/2019_2020 : SURGE ARRESTOR FOR DBs & VDBs<br>Supply, installation testing & commisisoning of pluggable type surge arrester in existing Vertical DB/Seven segment DB / Tier DB in additional DIN bar alongwith the same Din Rail (4+0) Surge Protection Device Class C/ Type 2 Tested as per IEC 61643 Part 11:2016 . Total Max Discharge current 200 KA (8/20µ sec), Voltage protection level <1.5 kV . The Surge Protection Devices should have TOV safefail for 120 Min : 442 V . Protective Elements are MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25kA/50 kA Back up fuse required more than 200AgG/gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec including all accesories as required for complete installation<br>Supply & Labour<br> | 52 | each | |
| 922 | 22.58 | TERMINATION BOXES | |||
| 923 | 22.59 | od308353/2019_2020 : TERMINATION BOXES<br>Supply, installation, testing and commisioning of self extinguishing, weatherproof cabinets suitaible tfor outdoor application (IP 65, IK 09) with reversible door and cabinet with terminals for looping of cables and rail for fixing modular isolator along with 25A DP isolator including all connections and interconnections as required for outdoor application as instructed by engineer in charge. | 2 | each | |
| 924 | 22.6 | HORIZONTAL DRILLING | |||
| 925 | 22.61 | od308360/2019_2020 : HORIZONTAL DRILLING<br>Drilling, boring and rimming including labour charges for horizontal drilling across existing road for laying of HDPE pipe excluding pipe | 20 | metre | |
| 926 | 22.62 | CABLE MANAGEMENT SYSTEM | |||
| 927 | 22.63 | od308361/2019_2020 : Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. <br>32 x 12.5mm CMS | 50 | metre | |
| 928 | 22.64 | THREE PHASE DIRECT MULTIFUNCTION METER | |||
| 929 | 22.65 | od299797/2020_2021 : THREE PHASE DIRECT MULTIFUNCTION METER<br>Supply, installation, testing and commisioning of<br>Multifunction Meter DIN Rail Mounted with Three Phase Direct Input up to 125A, Cl 1.0 Accuracy, with<br>LCD Display, able to measure Parameters Voltage, Current, Active Power & Active Energy and able to<br>communicate via RS485 Modbus Protocol to connect with Energy Management / Building Management<br>System including all accesories as required to be installed in tier DBs, enclosures etc as required.. | 8 | each | |
| 930 | 22.66 | UPS | |||
| 931 | 22.67 | od308700/2019_2020 : 3 x 160 kVA UPS in PRS Mode<br>Supply, installation, and commissioning of 3x 160 kVA UPS Three phase in and out swith PRS configuration UPS. with indoor (IP20) with surge protection system with SMF battery of reputed approved make exide/quanta/panasonic), Input pf >0.99, input THDi <3 % without use of any external filters, isolation transformers at output, double conversion technology with input voltage range 208-477 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, SNMP card for network monitoring, Compatibility etc. It shall be 100% generator compatible, with Efficiency upto 96% and output power factor minimum .9, Eco mode Efficiency upto 99% and including all accessories etc as required.The system shall comply to EN 62040-1, IEC 61000-4, IEC 62040-2 and relevant IS & statutory standards. The acoustic noise at 1m of the system should be <73dB. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter. warranty minimum 2 years to be provided by manufacturer for UPS and batteries. UPS shall be with parallel redundancy feature with expansion upto 6 units with emergency power off availiable local and remote with an event log of 3000 records minimum. All The UPS shall be with BMS card/module for integrating with IBMS using Modbus/BackNet protocol <br>"160kVA UPS with Isolation Transformer in output - 3Nos, Battery Circuit Breaker-3Nos, SNMP for Remote Monitoring -3Nos<br>Battery -12V sealed maintenance free batteries (SMF VRLA) with required number of batteries of required Ah as per manufacturer for providing 30 Minutes Back up for each UPS and it shall be connected in single string with Battery Accessories like battery rack, interconnecting cables, battery isolators etc."<br> | 1 | each | |
| 932 | 22.68 | LIGHTNING & EARTHING PROTECTION | |||
| 933 | 22.69 | od308817/2019_2020 : Providing coil/spring earthing using 2 runs of 8SWG, GI wire for street light pole etc. GI wire buried to a minimum depth of 1.5m, with excavation, refilling and connecting GI wire to pole using bolt and nut complete including all accessories required. | 19 | each | |
| 934 | 22.7 | od308818/2019_2020 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>25x3mm Cu strips tinned at the point of contact | 50 | metre | |
| 935 | 22.71 | od308819/2019_2020 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.<br>Copper wire No.8 SWG | 750 | metre | |
| 936 | 22.72 | od308820/2019_2020 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.<br>Copper wire No.10 SWG | 2720 | metre | |
| 937 | 22.73 | od308821/2019_2020 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.<br>25x3mm Cu strips tinned at the point of contact | 2603 | metre | |
| 938 | 22.74 | od308822/2019_2020 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.<br>50x6mm Cu strips tinned at the point of contact | 100 | metre | |
| 939 | 22.75 | od308823/2019_2020 : Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances. The mineral compound is required to have minimum 30 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 320mmx 320mmx 190mm with a weight bearing capacity of 50KN. Govt approved Indian labs test certificate required. | 2 | set | |
| 940 | 22.76 | od308824/2019_2020 : Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Single bolt joints are not permitted. Govt approved Indian labs test certificate required. | 65 | each | |
| 941 | 22.77 | od308825/2019_2020 : Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.<br>Terrace Conductor Fibre Reinforce Concrete Holder @ every 1 meters | 48 | metre | |
| 942 | 22.78 | od308826/2019_2020 : Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.<br>Down Conductor Holder made of whether resistant plastic @ every 0.8 meters | 18 | metre | |
| 943 | 22.79 | od308827/2019_2020 : Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.<br>Parapet Holder made of whether resistant plastic @ every 0.4 meters | 408 | metre | |
| 944 | 22.8 | od308828/2019_2020 : Providing and fixing Fully Solid Vertical Air terminals as per IS/IEC -62305 part-3 For air terminal 16mm rod tapered to 10 mm aluminium rod meter rod:Meets the requirement (IS/IEC 62305), Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal.System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. Stainless Steel Wall Clamp/16 KG stone of 365 mm diameter, high level of stability. No of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked.Govt approved Indian labs test certificate required.<br>4 meter air terminal with necessary mounting accessories | 6 | set | |
| 945 | 22.81 | od308829/2019_2020 : Providing and fixing Fully Solid Vertical Air terminals as per IS/IEC -62305 part-3 For air terminal 16mm rod tapered to 10 mm aluminium rod meter rod:Meets the requirement (IS/IEC 62305), Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal.System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. Stainless Steel Wall Clamp/16 KG stone of 365 mm diameter, high level of stability. No of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked.Govt approved Indian labs test certificate required.<br>2 meter air terminal with necessary mounting accessories | 3 | set | |
| 946 | 22.82 | od308830/2019_2020 : Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 80x150 for Neutral Earthing of Transformer, DG application. Minimum 5 connections to structural steel Required. Earth stud with connecting accessories inside the concrete - ( Earth stud + 1 no of Mild Steel multi purpose bonding clamp - Double plate clamp + 8 nos of Diagonal clamp + 5 nos of connecting point + Green cover ). Govt approved Indian labs test certificate required. | 6 | each | |
| 947 | 22.83 | od308831/2019_2020 : Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 70x100 for Body Earthing of Panel, Transformer, DG application. Minimum 3 connections to structural steel Required. This has to connected to heavy duty Stainless steel bonding rail to take multiple connection. Earth stud with connecting accessories inside the concrete - ( Earth stud + 1 no of multi purpose bonding clamp - Double plate clamp + 4 nos of Diagonal clamp + 3 nos of connecting point + Green cover). Govt approved Indian labs test certificate required. | 13 | each | |
| 948 | 22.84 | od308832/2019_2020 : Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 70x70 for General Earthing application. This has to be connected to equipotential bonding rail to take multiple connection, including equipotential rail. Earth stud with connecting accessories inside the concrete - ( Earth stud +Mild Steel multi purpose bonding clamp - Double plate clamp + connecting point + Green cover). Govt approved Indian labs test certificate required. <br> | 38 | each | |
| 949 | 22.85 | od308833/2019_2020 : Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 40x40 for Lightning Protection application. Earth stud with connecting accessories inside the concrete - ( Earth stud +Mild Steel multi purpose bonding clamp - Double plate clamp + connecting point + Green cover). Govt approved Indian labs test certificate required. | 32 | each | |
| 950 | 22.86 | od308834/2019_2020 : Installation of Exothermic Weld Joints for 18mm round copper bonded steel conductor having 100 microns or 40x6mm pure solid tape copper conductor as per IS/IEC 62305. Govt approved Indian labs test certificate required. <br> | 29 | each | |
| 951 | 22.87 | od308835/2019_2020 : Providing and laying copper bonded steel solid tape conductor 18mm having 250Sq mm cross sectional area . copper coated steel, high corrosion resistant (if pure copper conductor 40x6 solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. Needs to be installed in high fault level areas to form MAT inside structure. Govt approved Indian labs test certificate required. | 245 | metre | |
| 952 | 22.88 | od308836/2019_2020 : Providing & fixing of Stainless Steel Straight Connectors for straight Joints if required. Govt approved Indian labs test certificate required. | 196 | each | |
| 953 | 22.89 | od308837/2019_2020 : Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns or 25x3mm pure solid tape copper conductor as per IS/IEC 62305. Govt approved Indian labs test certificate required. | 120 | each | |
| 954 | 22.9 | od308838/2019_2020 : STRUCTURAL EARTHING & LIGHTNING PROTECTION<br>Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3 mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required. <br>For Ring Earthing needs to be installed 0.5 meter from earth. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm.<br> | 300 | metre | |
| 955 | 22.91 | od308839/2019_2020 : STRUCTURAL EARTHING & LIGHTNING PROTECTION<br>Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3 mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required. <br>Vertical Riser Outside Structure | 72 | metre | |
| 956 | 22.92 | od308840/2019_2020 : STRUCTURAL EARTHING & LIGHTNING PROTECTION<br>Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3 mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required. <br>Inside Structure for the formation of MAT & Vertical Riser Inside Structure this has to be installed with bonding clamp @ every 3 meters tested as per IS/IEC 62305.Interconnecting round conductor and reinforcement inside the concrete for structural earthing system. | 1564 | metre | |
| 957 | 22.93 | RISING MAINS, BBT & TAP OFF BOXES | |||
| 958 | 22.94 | od308952/2019_2020 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation, compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation.. Each raising main should be with 2 Tap-off points in each floor. It should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.<br>800A Al TPN IP54 Rising Mains | 28 | metre | |
| 959 | 22.95 | od308953/2019_2020 : Supply, installation testing & commisioning of following rating and breaking capacity electricaly drawn out type ACB in enclosure TS profile based. Enclosure shall be wall mountable and shall be as per specification provided for MV panels. The adaptor box with ACB shall be fabricated for connecting rising mains of rating corresponding ACB rating with complete accesories including RYB indication, all interconnections providing cable entry in bottom for 4R of 400sqmm A2XFY cable complete with all accesories and as instructed by engineer in charge <br>1250A 4P 50kA EDO ACB in enclosure | 1 | each | |
| 960 | 22.96 | od308954/2019_2020 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>125A 36kA FP MCCB in Plug in box | 2 | each | |
| 961 | 22.97 | od308956/2019_2020 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>400A 36kA FP MCCB in Plug in box | 3 | each | |
| 962 | 22.98 | od308957/2019_2020 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>630A 36kA FP MCCB in Tap off box | 1 | each | |
| 963 | 22.99 | od308958/2019_2020 : RISING MAINS, BBT & TAP OFF BOXES<br>Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation, compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation.. Each raising main should be with 2 Tap-off points in each floor. It should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.<br>1250A Al TPN IP54 Rising Mains | 20 | metre | |
| 964 | 23 | od311915/2019_2020 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral) bus trunking on wall / ceiling / structure, with high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows, adaptor boxes for termination in panels . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip (Cu strip shall go inside LT panels and end termination boxes) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including all type of bends, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Bus bar connection between transformers and panel, DG synch panel & Main panel is considered in this item)<br>1600A Al TPN IP54 Feeder busduct | 10 | metre | |
| 965 | 23.01 | LT PANELS | |||
| 966 | 23.02 | od309016/2019_2020 : 300 kVAr APFC PANEL <br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters , 3 nos between Line and Neutral and one number arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-35 KA (10/350µ sec) for each Line to Neutral & 100 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.5 KV ( L to N) & <1.5 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Automatic power factor control panel of rating 300 kVAr with 7% harmonic block reactor with tuned capacitors using capacitor swtiching. By using Microprocessor based relay operated controller with minimum 12 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching.630A 36kA 4P MCCB with high rupturing capacity and in built overload and short circuit releases as per specifications as incomer, , housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes in steps of 14 (40 kVAR x3)+ (25kVAR x6)+(10kVAR x3) required rating of capacitor shall be directly connected to the main bus for no load compensation. The capacitors shall be with U.L listed pressure sesitive interrupter, inside hermctically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage <50Vwithin one min of de-energisation.. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control. <br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Metering : R Y B Indication with control fuse -1Set, Automanual selector switch- 1No , Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge/consultant. (Make : Sprague, Inel or equivalent)<br>Supply, Installation, erection, testing and commissioning <br> | 1 | each | |
| 967 | 23.03 | od309023/2019_2020 : FIRE LIFT PANEL <br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by Rittal Authorised Panel Integrator).<br>Incomer -<br>100A TPN Isolator - 2 Nos.<br>100A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Outgoings<br>63A 100mA FP RCBO - 2 nos.<br>25A 30mA DP RCBO - 1 no.<br>6A SP MCB - 4 nos.<br>Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Supply, Installation, erection, testing and commissioning <br> | 1 | each | |
| 968 | 23.04 | od309024/2019_2020 : FIRE PANEL <br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, symmetrical, stable profile frame based construction. LT panel board of suitable size for 415V, 3 phases, 4 Wire 50 Hz AC supply system having provisions of cable end termination chambers and fabricated in compartmentalized design. Panel should have a fully corner welded construction with more than 15 fold profile with min 25mm din pitch pattern fabricated by any reputed make. All load bearing members like partial doors should be from 2mm DD grade CRCA with 2mm GI mounting plate. All the internal partitions should be galvanised sheets of 1.6mm. All painted non load bearing members like full height side cover, full height bolted covers should be 1.5mm. All raw sheets should be cleaned thoroughly from all directions by a conveyorized cleaning process to avoid salt sedimentation at corners. After pre cleaning, all the flat sheets should undergo Electrophoretic dip coating and powder coating with RAL 7035 or RAL 7032.The thickness should be 80-120microns. All doors should have a poly urethane form gasketing for higher IP protection with 2 Nos. earth stud, cable alleys, removable gland plates. Modular, easily extendable TS profiled Enclosure systems with Horizontal and / or vertical bus bar and cable compartment, with standard gland plates. Cubicle Separation plate, cross members and equipment mounting plates are galvanized Iron (GI). Partial doors, covers are with PU foamed gaskets integrated to ensure high degree (IP54) of ingress protection. Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by any Authorised Panel Builders of above make).<br>This panel should include DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 260KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV withstand for 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25kA/50 kA . Back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <100 nano sec .Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomer<br>500A TPN Isolator - 1 No.<br>500A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Instruments<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B&C/ Type 1&2 and fuse for protection of the same - 1 set<br>Outgoings<br>250A TP ISOLATOR for 75HP pump along with starter w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms - 2 nos.<br>63A TP ISOLATOR for 15HP pump along with starter w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms - 2 nos.<br>100A TPN ISOLATOR - 1 no.(for Fire Lift)<br>Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Supply, Installation, erection, testing and commissioning <br> | 1 | each | |
| 969 | 23.05 | od309027/2019_2020 : LIFT PANEL 1 & 2<br>Supplying, installation, testing & commissioning of cubical type, dust and vermin proof, floor mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Make of Panels :- Rittal (Assembled by Rittal Authorised Panel Integrator).<br>Incomer -<br>100A TPN Isolator - 1 No.<br>100A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>63A 100mA FP RCBO - 3 nos.<br>25A 30mA DP RCBO - 1 no.<br>6A SP MCB - 8 nos.<br>Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Supply, Installation, erection, testing and commissioning <br> | 2 | each | |
| 970 | 23.06 | SUB MAIN DISTRIBUTION BOARDS(SMDB) / LOADBANKS | |||
| 971 | 23.07 | od299798/2020_2021 : 4 WAY SMDB SECOND & THIRD FLOOR RIGHT WING<br>Supply, erection, testing and<br>commissioning of floor mounting type, double door 3 phase 4 way SMDB. IP43 ingress protection and<br>quality with cable end boxs, meter module, add on module for adding surge arrestor including busbar,<br>neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as<br>shown in the schematic drawing, Providing all connections and interconnections as required and<br>providing all assecories as required for complete installation as instructed by engineer in<br>charge/consultant. SMDB shall comply with latest IEC 61439-2 standard with full safety reliability test<br>certificates (Dekra and Asta certified). All MCCBs used shall be 100% Ics rated. Short-time withstand<br>current for SMDB should be 36kA for 1s. SMDB shall be supplied with following accesories-<br>250A<br>rated SMDB - 4 way with all accessories - 1 no.<br>Meter extension Box - 1 set<br>1- phase Ammeter -<br>3 nos<br>Voltmeter with voltage selector switch- 1 no<br>RYB indication lamps - 1 set<br>Side cabling<br>box - 2 nos.<br>Bottom cabling box with provision for adding Surge arrestor alongwith fuses - 1 no<br><br>Mounting base - 1 no.<br>Corner box - 4 nos<br>Incomer - 200A FP 25kA thermal magnetic release<br>MCCB -1No.<br>Outgoings<br>125A 16kA TP MCCB, with thermal magnetic release - 1 no. <br>100A<br>16kA TP MCCB, with thermal magnetic release - 1 no. <br>32A 16kA TP MCCB, with thermal magnetic<br>release - 2 nos. | 1 | each | |
| 972 | 23.08 | SAFETY EQUIPMENTS | |||
| 973 | 23.09 | od309131/2019_2020 : Supply & fixing of Class A Electrical rubber mat, used for high voltage 11kV , 2 Mtr x 1 Mtr size 3 mm thick, as per IS. 15652 - 2006. with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required | 14 | sqm | |
| 974 | 23.1 | od309132/2019_2020 : Supply of 1 pair 11 KV rubber hand gloves of approved make. | 1 | set | |
| 975 | 23.11 | od309133/2019_2020 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer. | 1 | each | |
| 976 | 23.12 | od309134/2019_2020 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc. | 4.5 | sqm | |
| 977 | 23.13 | od309135/2019_2020 : Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work. | 1 | each | |
| 978 | 23.14 | od309136/2019_2020 : Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision. | 1 | each | |
| 979 | 23.15 | od309137/2019_2020 : Supply and providing First Aid Box. | 1 | each | |
| 980 | 23.16 | od309138/2019_2020 : Supply & fixing of Class A Electrical rubber mat, used for up to 3.3 kV, Dielectric Strength of 33 kV , 2 Mtr x 1 Mtr size 2 mm thick, as per IS. 15652 - 2006 in front of various type MV panels. as per IS:15652 - 2006 with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required | 30 | sqm | |
| 981 | 23.17 | od309139/2019_2020 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. | 10 | each | |
| 982 | 23.18 | CABLE TRAY | |||
| 983 | 23.19 | od311150/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>400mm width x 60mm Height | 331 | metre | |
| 984 | 23.2 | od311151/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>300mm width x 60mm Height | 23 | metre | |
| 985 | 23.21 | od311152/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>200mm width x 60mm Height | 42 | metre | |
| 986 | 23.22 | od311153/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>150mm width x 60mm Height | 193 | metre | |
| 987 | 23.23 | od311154/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>100mm width x 60mm Height | 648 | metre | |
| 988 | 23.24 | od311155/2019_2020 : Supply and fixing of Perforated Cable tray with suitable wire supports and brackets and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for changing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana)<br>500mm width x 60mm Height | 149 | metre | |
| 989 | 23.25 | LIASIONING WORKS | |||
| 990 | 23.26 | PLUMBING ITEMS | |||
| 991 | 23.27 | od128894/2020_2021 : Providing and fixing of automatic sensing high jet speed hand dryer both hot and hot<br>air of approved quality conforming to IS standards.make Dolphy abs plastic | 4 | each | |
| 992 | 23.28 | od128895/2020_2021 : Supply, instalation,testing and commissioning of approved make of vertical /<br>horizontal type Electric water heater suitable for pressure rating up to 4 Kg / Sqcm with heating element with<br>thermostat, pressure relief valve, non - return valve with CP copper connecting pipes with wall flanges etc.,<br>complete with all inlets, outlets, valves and all other accessories etc., complete. Toilet Geyser.3KG | 22 | each | |
| 993 | 23.29 | od128962/2020_2021 : Providing & fixing, testing and commissioning of approved make centrifugal<br>monoblock pumps for Raw water Filter feed water inside the Pump room. The quoted rate shall include<br>Automatic control panel with level switches, starters, dry run preventer, O/L relays, necessary wiring up to<br>the pumps and control panel, the pumps shall run 415V, 50Hz electric supply, complete. 1 working + 1 standby<br>7500 LPH @ 30 mtr head | 1 | each | |
| 994 | 23.3 | od128963/2020_2021 : Providing & fixing, testing and commissioning of SS centrifugal Waste water Transfer<br>Pump(grinder pump), for pumping waste water/ Kitchen waste/ sewage waste from collection pit to Sewage<br>treatment plant, with including solenoid valves, level switches, control wires etc. (1Working pump+standby)<br>with suitable HP Capacity:200lpm@25mtr head | 2 | each | |
| 995 | 23.31 | od128964/2020_2021 : Supply,Installation, testing and commission, of Twin booster pump with GI manifold,<br>for pumping water from overhead tank to domestic uses, with including solenoid valves, level switches,<br>control wires etc. Pump is of VFD type.The price shall inclusive of all connected electrical work. Capacity<br>1LPS. at 25 Mtrs. head, each, Electric motor driven, (HP as per selection of pump), 1 working, 1 assisted, 3<br>Phase, 415V, AC Supply Pump Classification: Twin Booster System,Total system flow: 2 LPS,Each pump<br>flow capacity: 1 LPS,Total Head: 25 M,Total no of pump: 2 Nos.,No of working pumps: 2 Nos,Pressure tank<br>capacity: 50 LTR | 1 | each | |
| 996 | 23.32 | od128965/2020_2021 : Providing & Fixing, testing and commission, of open well submersible Type Water Transfer Pump, for pumping water from Underground treated water tank to overhead domestic water tank, underground STP treated tank to OH flush water tank with including level switches, control wires ,startor etc. The price shall inclusive of all connected electrical work.Capacity 350 lpm at 50Mtrs. head, each, Electric motor driven, (HP as per selection of pump), 1 working +1 standby, three phase, 415V, AC Supply UG tank to OH domestic tank | 2 | each | |
| 997 | 23.33 | od128978/2020_2021 : Water level controller<br>Providing & Fixing, testing and commissioning of Automatic Three phase water level controllers with level sensors for submersible pump shall have the following<br>features <br>Switch off the motor when the water level in tank reaches a preset level below the over flow<br>pipe.<br>Switch ON the motor if the water level in tank goes down below a preset value near.<br>Switch off<br>the motor in the event of dry running.<br>Manual bypass mode. | 4 | each | |
| 998 | 23.34 | od150753/2020_2021 : Supply,Installation, testing and commission, of wall mounted/ table top 10 litre water purifier with grade ABS water tank having input water source filtering capabilty of TDS upto 2000ppm.The unit includes RO membarne,filters etc. | 9 | each | |
| 999 | 23.35 | ISOLATOR FOR CHILLER | |||
| 1000 | 23.36 | od129377/2020_2021 : ISOLATOR FOR CHILLER<br>"Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface with terminal shrouds on both sides and phase barriers included<br>Conforms to IEC 60947-3, IS/IEC 60947-3e complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation."<br>500A FP Isolator with enclosure | 2 | set |