Kerala State Electricity Board-KSEB has published Supply Installation Testing Commissioning And Technical Support Of Network Active And Passive Components And Ups Wiring. Submission Date for this Tender is 03-04-2021. Screws Tenders in For Destination Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Mar-2021 | date corrigendum 1 | Date | 23-03-2021 |
2 | 25-Mar-2021 | Date Extension | Date | 27-03-2021 |
3 | 29-Mar-2021 | Date Corrigendum 3 | Date | 31-03-2021 |
4 | 31-Mar-2021 | date 4 corrigendum | Date | 03-04-2021 |
Name of Work: Supply, Installation, Testing, Commissioning and Technical Support of Network Active & Passive Components and UPS wiring at Government Medical College Hospital, Kottayam | |||||
---|---|---|---|---|---|
Sl. No. | Item Description(All items as per the full compliance with the items in Annexure-4) | Item Code / Make | Quantity | Units | |
1 | 1 | Outdoor O. F. Cable 6 core SM | 1750 | Mtr | |
2 | 2 | 24 Port Fully loaded LIU Rack mountable | 3 | Nos | |
3 | 3 | 12 Port Fully loaded LIU Rack mountable | 5 | Nos | |
4 | 4 | 6 Port Fully loaded LIU Rack mountable | 6 | Nos | |
5 | 5 | LC to SC Patch cord. SM | 20 | Nos | |
6 | 6 | Cat6 4 Pair UTP Cable: 23 AWG | 8845 | Mtr | |
7 | 7 | Cat6 Information Outlet | 184 | Nos | |
8 | 8 | Face plate Singlex - Cat6 | 184 | Nos | |
9 | 9 | 3 x 3 Surface mount box for Cat6 Outlet | 184 | Nos | |
10 | 10 | Cat6 patch cord,3 mtr | 184 | Nos | |
11 | 11 | Cat6 patch cord, 1 mtr | 200 | Nos | |
12 | 12 | Cat6 patch panel 24 port Fully Loaded | 12 | Nos | |
13 | 13 | Cat6A 4 Pair UTP Cable | 1830 | Mtr | |
14 | 14 | Cat6A Information outlet | 27 | Nos | |
15 | 15 | Face plate Duplex.- Cat6 A | 27 | Nos | |
16 | 16 | 3 x 3 Surface mount box for Cat6A Outlet | 27 | Nos | |
17 | 17 | Cat6A patch cord,3 mtr | 27 | Nos | |
18 | 18 | Cat6A patch cord, 1 mtr | 27 | Nos | |
19 | 19 | Cat6A patch panel 24 port Fully Loaded | 2 | Nos | |
20 | 20 | 36U Floormount Rack with Accessories | 1 | Nos | |
21 | 21 | 27U Floormount Rack with Accessories | 1 | Nos | |
22 | 22 | 12U Wallmount Rack with Accessories | 2 | Nos | |
23 | 23 | 9U Wallmount Rack with Accessories | 3 | Nos | |
24 | 24 | 6U Wallmount Rack with Accessories | 4 | Nos | |
25 | 25 | Supply of 25mm ISI PVC Conduit with accessories - Ivory | 3000 | Mtrs | |
26 | 26 | Supply of L Type Clamp for fixing of DLP | 100 | Nos | |
27 | 27 | PVC Cable Management System with all accessories(DLP): 100x50 mm | 105 | Mtrs | |
28 | 28 | PVC Seperator for Cable Management System | 105 | Mtrs | |
29 | 29 | Supply of Perforated Cable tray 200 X 60 MM including all accessories | 300 | Mtrs | |
30 | 30 | Supply of 32 mm HDPE Pipe | 650 | Mtrs | |
31 | 31 | Supply of Cable Route Marker with Angle Iron Leg 2 ft with painting | 8 | Nos | |
32 | 32 | Branch Router with 2 WAN and 4 LAN | 1 | Nos | |
33 | 33 | 5 year 24X7 support pack for branch router | 1 | Nos | |
34 | 34 | Fully Managed 12 Port 10G SFP+Fiber Distribution Switch with all accessories | 2 | Nos | |
35 | 35 | 5 year 24X7 support pack for core distribution switch | 2 | Nos | |
36 | 36 | L2 Fully Managed 24 Port Network Switch with 4*10G SFP+ uplink | 2 | Nos | |
37 | 37 | 5 year 24X7 support pack for L2 Fully Managed 24 Port Network Switch | 2 | Nos | |
38 | 38 | Fully Managed 24 Port Network Switch with 4 SFP Uplink | 12 | Nos | |
39 | 39 | 5 year 24X7 support pack for Fully Managed 24 Port Network Switch | 12 | Nos | |
40 | 40 | 10G SFP Module | 4 | Nos | |
41 | 41 | 1G SFP Module | 12 | Nos | |
42 | 42 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4C X 50 Sq.mm, 415 V | 50 | Mtrs | |
43 | 43 | Supply of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 50 Sq.mm , 415 V | 8 | Nos. | |
44 | 44 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4 X 35 Sq.mm, 415 V | 100 | Mtrs | |
45 | 45 | Supply of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 35 Sq.mm , 415 V | 16 | Nos. | |
46 | 46 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm, 415 V | 1500 | Mtrs | |
47 | 47 | Supply of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V | 52 | Nos. | |
48 | 48 | Supply of 4 way double door MCCB VDB with 100A MCCB as incomer | 1 | Nos | |
49 | 49 | Supply of 4 way double door MCCB VDB with 63A MCCB as incomer | 1 | Nos | |
50 | 50 | Supply of 4 way double door MCCB VDB with 40A MCCB as incomer | 4 | Nos | |
51 | 51 | Tap of Box with 125A / 4 P MCCB for tapping input from Rising Main | 1 | Nos | |
52 | 52 | Supply of 16 way SP DB | 1 | Nos | |
53 | 53 | Supply of 12 way SP DB | 10 | Nos | |
54 | 54 | Supply of 8 way SP DB | 2 | Nos | |
55 | 55 | Supply of 2 Pole Isolator 40A | 13 | Nos | |
56 | 56 | Supply of 2 Pole ELCB 40A 100ma Leakage | 13 | Nos | |
57 | 57 | Supply of 3 Pole MCB 63A | 2 | Nos | |
58 | 58 | Supply of 3 Pole MCB 40A | 4 | Nos | |
59 | 59 | Supply of 3 Pole Enclosure | 6 | Nos | |
60 | 60 | Supply of 2 Pole MCB 40A | 3 | Nos | |
61 | 61 | Supply of 2 Pole Enclosure | 3 | Nos | |
62 | 62 | Supply of 1 Pole MCB 40A | 14 | Nos | |
63 | 63 | Supply of 1 Pole MCB 16A | 11 | Nos | |
64 | 64 | Supply of 1 Pole MCB 6A | 68 | Nos | |
65 | 65 | Supply of 35 sq mm Flexible Copper Cable | 50 | Mtrs | |
66 | 66 | Supply of Cable Termination for 35 Sq. MM PVC insulated Copper Cable | 10 | Nos. | |
67 | 67 | Supply of 10 sq mm Flexible Copper Cable | 30 | Mtrs | |
68 | 68 | Supply of Cable Termination for 10 Sq. MM PVC insulated Copper Cable | 8 | Nos. | |
69 | 69 | Supply of 6 sq mm Flexible Copper Cable | 30 | Mtrs | |
70 | 70 | Supply of Cable Termination for 6 Sq. MM PVC insulated Copper Cable | 6 | Nos. | |
71 | 71 | Supply of 2 nos of 4 sq mm and 1 nos of 2.5 sq mm PVC insulated Copper Wire | 500 | Mtrs | |
72 | 72 | Supply of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire | 5420 | Mtrs | |
73 | 73 | Supply of 2 X 10 SWG Bare Copper | 1500 | Mtrs | |
74 | 74 | Supply of 3 nos 6A socket controlled by 3 switch with Back box and Cover | 26 | Nos | |
75 | 75 | Supply of 2 nos 6A socket controlled by 2 switch with Back box and Cover | 137 | Nos | |
76 | 76 | Supply of 1 nos of 16A socket controlled by 1 switch with Back box and Cover | 11 | Nos | |
77 | 77 | Supply of 1 nos of 6A socket controlled by 1 switch with Back box and Cover | 33 | Nos | |
78 | 78 | Supply of 20 mm PVC Conduit with all accessories - Black | 2500 | Mtrs | |
79 | 79 | Supply of Exhaust Fan - 12" | 3 | Nos | |
80 | 80 | Supply of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 | 6 | Nos | |
81 | 81 | Supply of 25X 6 MM GI earthing strip inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. | 100 | Mtr | |
82 | 82 | Supply of 25 X 6 MM Cu Strip for Earth Bunch | 2 | Mtr | |
83 | 83 | Laying of OF Cable through PVC Conduit/ HDPE Pipe | 1750 | Mtrs | |
84 | 84 | Splicing of OFC | 144 | Nos | |
85 | 85 | Termination of LIU | 14 | Nos | |
86 | 86 | Laying of 4 Pair UTP Cable Cat6 | 8845 | Mtrs | |
87 | 87 | Laying of 4 Pair UTP Cable Cat6A | 1830 | Mtrs | |
88 | 88 | Fixing and termination of Information outlet with SMB- Cat6 | 184 | Nos | |
89 | 89 | Fixing and port termination of patch panel- Cat 6 | 12 | Nos | |
90 | 90 | Fixing and termination of Information outlet with SMB- Cat6A | 27 | Nos | |
91 | 91 | Fixing and port termination of patch panel- Cat 6A | 2 | Nos | |
92 | 92 | Fixing & Dressing of Floormount Rack | 2 | Nos | |
93 | 93 | Fixing & Dressing of wallmount Rack | 9 | Nos | |
94 | 94 | Laying of PVC Conduit | 3000 | Mtrs | |
95 | 95 | Fixing of PVC Cable Management System with all accessories (DLP): 100x50 mm | 105 | Mtrs | |
96 | 96 | Fixing of Perforated Cable tray 200X 60 MM including all accessories | 300 | Mtrs | |
97 | 97 | Digging, Laying of HDPE/Water Pipe in Hard Soil / Tar-Road / Concrete Excavation/Trenching, Baked-Brick- Layering, Refilling & Restoration/Resurfacing, upto 600mm depth.(For laying of UTP/OFC) | 650 | Mtrs | |
98 | 98 | Fixing of Cable Route Marker | 2 | Nos | |
99 | 99 | UTP Node testing using Fluke Meter | 127 | Nos | |
100 | 100 | Fibre Testing using OTDR Meter | 96 | Nos | |
101 | 101 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4C X 50 Sq.mm, 415 V | 50 | Mtrs | |
102 | 102 | Fixing of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 50 Sq.mm , 415 V | 8 | Nos. | |
103 | 103 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4 X 35 Sq.mm, 415 V | 100 | Mtrs | |
104 | 104 | Fixing of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 35 Sq.mm , 415 V | 16 | Nos. | |
105 | 105 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm, 415 V | 1500 | Mtrs | |
106 | 106 | Fixing of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V | 52 | Nos. | |
107 | 107 | Fixing of 4 way double door MCCB VDB with 100A MCCB as incomer | 1 | Nos | |
108 | 108 | Fixing of 4 way double door MCCB VDB with 63A MCCB as incomer | 1 | Nos | |
109 | 109 | Fixing of 4 way double door MCCB VDB with 40A MCCB as incomer | 4 | Nos | |
110 | 110 | Fixing of Tap of Box with 125A / 4 P MCCB for tapping input from Rising Main | 1 | Nos | |
111 | 111 | Fixing of 16 way SP DB | 1 | Nos | |
112 | 112 | Fixing of 12 way SP DB | 10 | Nos | |
113 | 113 | Fixing of 8 way SP DB | 2 | Nos | |
114 | 114 | Fixing of 2 Pole Isolator 40A | 13 | Nos | |
115 | 115 | Fixing of 2 Pole ELCB 40A 100ma Leakage | 13 | Nos | |
116 | 116 | Fixing of 3 Pole MCB 63A | 2 | Nos | |
117 | 117 | Fixing of 3 Pole MCB 40A | 4 | Nos | |
118 | 118 | Fixing of 3 Pole Enclosure | 6 | Nos | |
119 | 119 | Fixing of 2 Pole MCB 40A | 3 | Nos | |
120 | 120 | Fixing of 2 Pole Enclosure | 3 | Nos | |
121 | 121 | Fixing of 1 Pole MCB 40A | 14 | Nos | |
122 | 122 | Fixing of 1 Pole MCB 16A | 11 | Nos | |
123 | 123 | Fixing of 1 Pole MCB 6A | 68 | Nos | |
124 | 124 | Termination of 35 sq mm Flexible Copper Cable | 10 | Nos | |
125 | 125 | Termination of 10 sq mm Flexible Copper Cable | 8 | Nos | |
126 | 126 | Termination of 6 sq mm Flexible Copper Cable | 6 | Nos | |
127 | 127 | Laying of 2 nos of 4 sq mm and 1 nos of 2.5 sq mm PVC insulated Copper Wire | 500 | Mtrs | |
128 | 128 | Laying of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire | 5420 | Mtrs | |
129 | 129 | Laying of 2 X 10 SWG Bare Copper | 1500 | Mtrs | |
130 | 130 | Fixing of 3 nos 6A socket controlled by 3 switch with Back box and Cover | 26 | Mtrs | |
131 | 131 | Fixing of 2 nos 6A socket controlled by 2 switch with Back box and Cover | 137 | Mtrs | |
132 | 132 | Fixing of 1 nos of 16A socket controlled by 1 switch with Back box and Cover | 11 | Nos | |
133 | 133 | Fixing of 1 nos of 6A socket controlled by 1 switch with Back box and Cover | 33 | Nos | |
134 | 134 | Laying of 20 mm PVC Conduit accessories | 2500 | Nos | |
135 | 135 | Fixing of Exhaust Fan - 12" | 3 | Mtrs | |
136 | 136 | Fixing of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 | 5 | Nos | |
137 | 137 | Laying of 25X 6 MM GI earthing strip inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. | 100 | Mtrs | |
138 | 138 | Fixing 25 X 6 MM Cu Strip for Earth Bunch | 2 | Mtrs |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail