Name of Work: PROVISION OF POL STORE AT SITE-III BAKNAUR UNDER GE (AF) AMBALA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Surface excavation not exceeding 30cm deep and averaging 15cm deep in soft / loose soil and getting out including taking out roots, shrubs, etc. complete all as specified and as directed | 165 | Sqm | |
2 | 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed | 70 | Cum | |
3 | 3 | Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed | 60 | Each | |
4 | 4 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed | 48 | Cum | |
5 | 5 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed | 47 | Cum | |
6 | 6 | M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed | 10 | Cum | |
7 | 7 | M&L for fine dry river sand filling in under floors, foundations, etc. complete all as specified and as directed\nNote: Only punned thickness of sand shall be considered for measurement purposes | 8 | Cum | |
8 | 8 | M&L for forming embankments including raising earth raising from base, spreading in layers not exceeding 30cm thick, watering, ramming / rolling and finishing to required size, shape, etc. height not exceeding 1.5m from from base complete all as specified and as directed | 10 | Cum | |
9 | 9 | M&L for treating the backfill in contact with foundation @7.5litres of emulsion per square metre of vertical surface (area of the sub-structure in contact with backfill to be measured) complete all as specified and as directed | 30 | Sqm | |
10 | 10 | M&L for treating the top surface of filled earth @5litres of emulsion per square metre of surface complete all as specified and as directed | 45 | Sqm | |
11 | 11 | M&L for treating the soil under plinth protection @5litres of emulsion per square metre of surface area complete all as specified and as directed | 22 | Sqm | |
12 | 12 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade-‘B’ complete all as specified and as directed | 5 | 10Rm | |
13 | 13 | M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation filling, mass concrete, etc. complete all as specified and as directed | 3 | Cum | |
14 | 14 | M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in filling of post holes, mass concrete, etc. complete all as specified and as directed | 13 | Cum | |
15 | 15 | M&L for 75mm thick plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in sub-bases, etc. complete all as specified and as directed | 65 | Sqm | |
16 | 16 | M&L for 100mm thick plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in sub-bases, etc. complete all as specified and as directed | 165 | Sqm | |
17 | 17 | M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in plinth protection, etc. laid in bays including filling of construction joints with sealing compound grade-A complete all as specified and as directed | 50 | Sqm | |
18 | 18 | M&L for 100mm thick plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in flooring, sub-bses, etc. finished even and fair complete all as specified and as directed | 50 | Sqm | |
19 | 19 | M&L for 100mm thick plain cement concrete 1:2:4 (type B-2) using 40mm graded stone aggregate as in flooring, sub-bses, etc. finished even and fair complete all as specified and as directed | 165 | Sqm | |
20 | 20 | M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregates as in coping, padding, kerbs, bed blocks, locking of interlocking tiles, for hold fasts, etc. including necessary formwork complete all as specified and as directed | 1.3 | Cum | |
21 | 21 | M&L for RCC design mix, M-25 as in beams, cantilevers, lintels beams, roof beams, fins, fascia, louvers, parapets, railing, shelves, walls, etc. and similar works over 1.5m span complete all as specified and as directed | 5 | Cum | |
22 | 22 | M&L for RCC design mix, M-25 as in roof / floor slabs supported on walls, etc. and similar works over 1.5m span complete all as specified and as directed | 8 | Cum | |
23 | 23 | M&L for RCC design mix, M-25 as in columns, pillars, etc. and similar works complete all as specified and as directed | 3 | Cum | |
24 | 24 | M&L for RCC design mix, M-25 as in foundations, footings, plinth beams, etc. and similar works complete all as specified and as directed | 8 | Cum | |
25 | 25 | M&L for RCC design mix, M-25 as in chajjas, cantilevers, etc. and similar works complete all as specified and as directed | 0.25 | Cum | |
26 | 26 | Notes for item Nos. 21 to 25: Reinforcement and formwork will be measured and paid separately in respective items herein\n | |||
27 | 27 | M&L for formwork to sides and soffits of slabs, beams, chajjas, lintels, shelves, chullah hoods, etc. and similar works, including edges, for fair finished surfaces of concrete complete all as specified and as directed | 50 | Sqm | |
28 | 28 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar works, vertical or to batter for rough finished surfaces complete all as specified and as directed | 30 | Sqm | |
29 | 29 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces complete all as specified and as directed | 25 | Sqm | |
30 | 30 | M&L fo formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces complete all as specified and as directed | 50 | Sqm | |
31 | 31 | M&L for mild steel TMT bars grade Fe-500D, 10mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed | 2300 | Kg | |
32 | 32 | M&L for mild steel TMT bars grade Fe-500D, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed | 1000 | Kg | |
33 | 33 | --ditto-- al as per item No. 31 hereinabove but 5mm to 10mm dia and over upto and including 10mm dia as in stirrups, spacers, binders, etc. complete all as specified and as directed | 564 | Kg | |
34 | 34 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed | 100 | Kg | |
35 | 35 | M&L for framed works conforming to Fe 410-W (grade E-250) quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed | 610 | Kg | |
36 | 36 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 10mm complete all as specified and as directed | 15 | Kg | |
37 | 37 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in supports to chain link fencing complete all as specified and as directed | 277 | Kg | |
38 | 38 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in supports to chain link fencing complete all as specified and as directed | 1080 | Kg | |
39 | 39 | M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed | 32.7 | Cum | |
40 | 40 | M&L ffor rendering 15mm thick (average thickness) plaster, in cement mortar (1:3) on roof surfaces, flashings, junctions of parapet, mixed with integral water proofing compound finished even and smooth without using extra cement as in walls complete all as specified and as directed | 50 | Sqm | |
41 | 41 | M&L for rendering 15mm thick plaster, in cement mortar (1:4) on fair faces of brick masonry / concrete surfaces, finished even and smooth without using extra cement as in walls complete all as specified and as directed | 100 | Sqm | |
42 | 42 | M&L for rendering 10mm thick, in cement mortar (1:6) on fair faces of brick masonry / concrete surfaces, finished even and smooth without using extra cement as in walls complete all as specified and as directed | 72 | Sqm | |
43 | 43 | M&L for rendering 5mm thick, in cement mortar (1:3) on fair faces of brick masonry / concrete surfaces, finished even and smooth without using extra cement as in ceilings complete all as specified and as directed | 60 | Sqm | |
44 | 44 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white / colour wash on walls, etc. complete all as specified and as directed | 35 | Sqm | |
45 | 45 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white / colour wash on walls, etc. complete all as specified and as directed | 30 | Sqm | |
46 | 46 | M&L preparation of new plastered / unplastered wall surfaces of any description and applying two coats of cement based paints (tint as approved by the GE) as per manufacturer's instructions oner a coat of chalk whitning including all necessary staging, scaffolding, etc. complete all as specified and as directed | 40 | Sqm | |
47 | 47 | M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed | 75 | Sqm | |
48 | 48 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directed\nNote: Weght of chain link fencing shall be assessed through a BOO ordered by the AO | 660 | Kg | |
49 | 49 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provisioning of binding wire complete all as specified and as directed | 300 | Sqm | |
50 | 50 | M&L for laying pre-polished 80mm thick rubber moulded, double glossy, coloured, designer, interlocking tiles made of M-40 design mix concrete of approved design and shape with the crushing strength not less than 400kg/sqcm laid over and including 25mm thick (compacted thickness) sand bed (rate shall be included) complete all as specified and as directed | 165 | Sqm | |
51 | 51 | M&L for applying evenly a tack coat of in dustrial bitumen 85/25 @1.2kg/sqm including cleaning surfaces complete all as specified and as directed | 50 | Each | |
52 | 52 | M&L for Atactic Poly Propaneylene (APP) modified bituminous membrane, weight not less than 4.0kg/sqm, reinforced with non-woven polyester fibre @160gm/sqm by torch method as per manufacturer's instructions complete all as specified and as directed \nSpecifications for membrane:\n(i) Softening point 150oC minimum\n(ii) Cold flexibility (-)2oC minimum\n(iii) Single centre core non-woven polyester reinforcement of not less than 160gm/sqm\n(iv) Tensile strength of 650N/sqcm and 450N/sqcm in longitudinal and transverse directions respectively\n(v) Minimum elongation of >20% in both directions\n(vi) Dimensional stability of 1% maximum\n(vii) Water tightness / impermiable at 2kgf/sqcm\n(viii) Water absorption of not more than 1% on mass within 24hrs\n(ix) Overlaps of minimum 100mm on longitudinal direction and 150mm along transverse direction shall be maintained while laying \n | 50 | Sqm | |
53 | 53 | Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 2 core 16sqmm, 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed\nNote: Excavation and earthwork will be measured and paid separately under respective item herein | 150 | Rm | |
54 | 54 | M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed\nNote: Only punned thickness of sand shall be considered for measurement purposes | 10 | Cum | |
55 | 55 | Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed | 1 | 1000Nos. | |
56 | 56 | Supplying, fixing / laying steel water tubing, 50mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed | 15 | Rm | |
57 | 57 | Supplying, fixing / laying steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed | 6 | Rm | |
58 | 58 | M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories surface on walls, ceilings, etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for one light / fan point complete all as specified and as directed | 3 | Each | |
59 | 59 | S&F flame proof rotary type switch with termination box in aluminium alloy LM6 FLP 16A 250V with wire guard complete all as specified and as directed | 3 | Each | |
60 | 60 | S&F flame proof, heavy duty, metalic body with metalic blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 457mm sweep, 1440RPM, CFM 4000 with lauvers, suitable for gas / vapour group IIA & IIB and zone 1&S, IP- 65 protection class, in epoxy powder coated aluminium alloy and MS frame, with FPP/WP3/4'' ET brass in plated DC type cable gland and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including making hole on wall grouting bolts nuts washers, etc. complete all as speceified and as directed | 1 | Each | |
61 | 61 | S&F in position flame proof FLP/WP2x18W LED tube light fitting, 230V, 50Hz AC in aluminium housing, suitable for gas / vapour group IIA & IIB and zone 1&S, IP- 65 protection class, with FPP/WP3/4'' ET brass in plated DC type cable gland with 18W tube rod and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan complete all as speceified and as directed | 2 | Each | |
62 | 62 | S&F in position 75W, 230V, 50Hz LED street light fitting duly housed in pressure die cast aluminium housing, comprising of individual optical lens, electronic driver with THD<10%, efficiency>85% and PF more than 0.9 conforming to IP-65 protection class, rendering colour index of 75 with cool daylight output, internally pre-wired including connecting up with twin core twisted flexible copper conductor cable from FRP box complete all as specified and as directed | 7 | Each | |
63 | 63 | S&F MCB SPN, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed | 1 | Each | |
64 | 64 | S&F MCB SP, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed | 2 | Each | |
65 | 65 | S&F sheet metal enclosures for MCB distribution board 230V, SPN, 4 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed | 1 | Each | |
66 | 66 | S&F in repairs copper strip of size 20x3.0mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed | 70 | Rm | |
67 | 67 | M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and as directed | 1 | Each | |
68 | 68 | S&F air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed | 6 | Each | |
69 | 69 | M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI wire of size 4sqmm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specification complete all as specified and as directed | 1 | Each | |
70 | 70 | M&L for earthing using copper earthing strip with galvanised steel earth plate electode 600x600x3.15mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3.0mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed | 2 | Each | |
71 | 71 | Notes for serial item Nos. 69 & 70: \n(i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included\n(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item \n(iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge |