Repair Replacement Of Lt Panels Overhead Lines And Its Connected Items At Odf Kb Line And Mall Raod Etc Under Ge East Agra, AGRA CANTT-Uttar Pradesh

Military Engineer Services-MES has published Repair Replacement Of Lt Panels Overhead Lines And Its Connected Items At Odf Kb Line And Mall Raod Etc Under Ge East Agra. Submission Date for this Tender is 14-06-2021. Bolts Tenders in AGRA CANTT Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27082875
Corrigendum : Repair Replacement Of Lt Panels Overhead Lines And Its Connected Items At Odf Kb Line And Mall Raod Etc Under Ge East Agra
Open Tender
Indian
Uttar Pradesh
AGRA CANTT
14-06-2021

Tender Details

Repair Replacement Of Lt Panels Overhead Lines And Its Connected Items At Odf Kb Line And Mall Raod Etc Under Ge East Agra-1 Disconnecting / Taking Out Of Existing Old Unserviceable Under Ground Cable Any Description, Any Size And In Any Position Complete All As Directed. 2 Disconnecting / Taking Out Of Existing Old Unserviceable Lt Panels Any Description, Any Size And In Any Position Complete All As Directed. 3 Material And Labour Pcc 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregate Complete All As Specified And Diredcted For Foundation Of Taxi Light / Flood Light Fittngs / Feeder Pillar Box Etc. 4 Excavation In Trenches In Soft / Loose Soil N. Exc 1.5 Mtr Wide And Not Exc. 1.5 Meter Deep And Getting Out Including Forming Bottom Surface For Laying Of Cable Complete All As Specified And Directed. 5 Returning Filling Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exc 25 Cm Thick Complete All As Specified. 6 Removing Surplus Soil To A Distance N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Above The Starting Point All As Specified. 7 Supplying And Laying Sand Cushioning For Cable Protection In Trenches / Filling In Ducts At Sub Stations Complete All As Specified And Directed. 8 Supplying And Laying Bricks Old Size Sub Class ‘B’ Laid Flat Across The Cable With Length Of Whole Brick For Protection Of Cable Complete All As Specified And Directed. 9 Supply And Laying Connecting And Testing Xlpe Insulated Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Aluminium Conductor 1100V Grade Cross Sectional Area 95 Sq Mm 3.5 Core Complete All As Specified And Directed. Make Havells / Gloaster / Polycab 10 All As Per Above But 70 Sq Mm 3.5Core Complete 11 All As Per Above But 50 Sq Mm 4 Core Complete 12 All As Per Above But 25 Sq Mm 4 Core Complete 13 All As Per Above But 16 Sq Mm 2 Core Complete 14 M&L For Drilling Suitable Dia Horizontal Bore Holes Including Insertion / Laying Of 80Mm Bore Hdpe Pipe Of Any Description Below / Under Existing Road Surfaces / Floors At A Level Not Less Than 0.60 Mtr Etc With Using Mechanical / Or Manual Devices As Required At Site Including Making Good The Disturbed Surfaces To Match With The Existing After Laying Pipes Complete All As Specified And Directed By Engineer-In-Charge. Nnote : ( I ) Cost Of Equipment Tools And Plant Material ( Horizontal Boring Rig Machine ) Required For Boring Shall Be Arranged By Contractor At No Extra Cost To The Govt. 15 M & L For Gi Pipe Light Grade 50 Mm Dia With All Fitting Laid In Bore Holes / Trenches / Drain / Culvert Or Fixed Along With Pole / Wall Including 02 Nos Fi Clamps Of 25X3 Mm Including Nut, Bolts Etc. Complete All As Directed. Make Tata / Jindal / Prakash 16 M&L For Earthing Complete With Galvanized Earth Plate Electrode 600 X 600 X6mm Thick Burned Directly In Ground ( Earth Pit Not Less Than 2.5 M Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.75 M Below Normal Ground Level Connected To And Including Galvanized Steel Strip Of Size 32 X 6 Mm As Earth Lead Earth Plate To Bldg Test Point Including 40Mm Gi Light Grade Pipe For Earth Protection From Earth Point To Earth Plate Surrounded By 150Mm Thick Alternate Layers Of Charcoal Dust Mix All With 35% Common Salt, 20Mm Bore Medium Grade Gi Pipe For Watering Pcc Pit Type 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate, With Rcc 550Mm Thick Cover In 1:2:4 Type B-1 Reinforced With 8Mm Dia Ctd Bars @8Mm E / C Both Way. Gi Check Nut, Funnel With Wire Mesh Necessary Excavation And Earth Work In Any Type Of Soil All As Specified And Shown In Electrical Plate No 3 Of Mes Ssr Part I 2009. 17 Supply And Fix Cable Jointing Kit Suitable For 1100 Volts Grade Lt Cable For Outdoor Termination Heat Cold Type Joint Complete With Jointing Material And Accessories Suitable For 3.5 / 4 Core Xlpe Armoured Aluminium Conductor Cable Of Size 25 To50 Sqmm. Make : 3M / M-Seal / Denson / Reychem 18 Supply And Fix Cable Jointing Kit Suitable For 1100 Volts Grade Lt Cable For Outdoor Termination Cold Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3.5 / 4 Core Xlpe Armoured Aluminium Conductor Cable Of Size 70 To 95 Sqmm. Make : 3M / M-Seal / Denson / Reychem 19 Supply, Installation, Testing And Commissioning Of Outdoor Type Lt Main Feeder Pillar ( Ip-55 ) Powder Coated With Structural Siemens Grey Ral 7032 Shall Be Factory Fabricated Cubicle Panel Board As Per Is / Iec 61439-1 & 2 ( Cpri Approved ) Rated For Short Circuit Rating Of 50 Ka, Front And Back Operable And Lockable By Keys From Both Sides Having Louvers And Air Vent, Gasket An Totally Vermin Proof Made Out Of 3.15 Mm Thick Crca Sheet Duly Compartmentalized For Incoming And Outgoing Copper Bus Bar Duly Insulated With Colour Coded Heat Shrinkable Sleeves And Mounted On Dmc / Epoxy Insulators ( Size Not Less Than 50Mmx50mm Conical Type At A Maximum Interval Of 500Mm ) Of Not Less Than 1.5 Times The Rating Of Main Incommer. The Incommer And All Outgoing Shall Have Extention Link Of Capacity 1.5 Times The Rating Of Individual Feeder. If The Size Of Incoming / Outgoing Cable Is More Than 120 Sqmm, Then The Extention Link Shall Not Be Less Than 300 Mm Long, All Links Shall Be Insulated With Colour Coded Heat Shrinkable Sleeves And Supported Arms Dmc / Epoxy Insulators Having Provision For Termination Of Incommer And Outgoing Cables. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel Of Suitable Size, Duly Coated With Zinc Metal Coating. A Detachable Pre Drilled Gland Plate Of Thickness 3.15Mm Thick, Cold Zink Metal Coated Shall Be Provided With At The Bottom For Entry For Armoured Cable With Adequate Size Of Gland. Manufacturer Name Plate With Feeder Details And Danger Plate Shall Be Provided At Suitable Visible Place. 3 Mcb Sp For Protection Of Metering Shall Be Provided.Note:- Cost Fo Taking Down Existing Cable Connection From Existing Unsv Lt Panel, Making New Termination Using New Lugs / Thimble, Necessary Execvation For Takible Ng Out Loop Etc Is Deemed To Be Included In Above Rate N ( Ii ) All Mccb Shall Have Ics=Icu=100%, Thermal Megnatic Release, 4 Pole, Adjustable Type Make L & T, Abb, Legrand For Gwalior Road Capt Qtr, Cod Offrs Mess And Old Kb Line Nincoming:- N ( A ) Mccb , 4Pole , 400 Amp , 50Hz, 415 Volts 36 Ka, With Microprocessor Release Icu=36Ka & Ics=100% Icu With Adjustable Over Load Setting ( Minimum 80% To 100% ) Qty - 01 No. N ( B ) Busbar Minimum 1.5 Times Of Incomer :- 4 Nos ( Three For Phase And One For Neutral ) Made Of Copper Of Capacity Minimum 1.5 Times Of Incomer Noutgoing:- N ( A ) Mccb Capacity 200 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 02 Nos. N ( B ) Mccb Capacity 100Amp, 4 Pole, 415V, 50 C / S 25 Ka - 02 Nos. N ( C ) Mccb Capacity 63 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 01 Nos. Nmetering:- N ( A ) One No Digital Type Multi Function To Show 0-500 V Voltmeter With Selector Switch 0-800A Ammeter With Selector Switch, Kwh Meter And Set Of Cast Resin Cts 800 / 5A. N ( B ) Indicator Lamp Led Based With Lamp Holder - 03 Nos. N ( C ) Pcc Work For Grouting Of Feeder Pillar Box Complete 20 Supply, Installation, Testing And Commissioning Of Outdoor Type Lt Main Feeder Pillar ( Ip-55 ) Powder Coated With Structural Siemens Grey Ral 7032 Shall Be Factory Fabricated Cubicle Panel Board As Per Is / Iec 61439-1 & 2 ( Cpri Approved ) Rated For Short Circuit Rating Of 50 Ka, Front And Back Operable And Lockable By Keys From Both Sides Having Louvers And Air Vent, Gasket An Totally Vermin Proof Made Out Of 3.15 Mm Thick Crca Sheet Duly Compartmentalized For Incoming And Outgoing Copper Bus Bar Duly Insulated With Colour Coded Heat Shrinkable Sleeves And Mounted On Dmc / Epoxy Insulators ( Size Not Less Than 50Mmx50mm Conical Type At A Maximum Interval Of 500Mm ) Of Not Less Than 1.5 Times The Rating Of Main Incommer. The Incommer And All Outgoing Shall Have Extention Link Of Capacity 1.5 Times The Rating Of Individual Feeder. If The Size Of Incoming / Outgoing Cable Is More Than 120 Sqmm, Then The Extention Link Shall Not Be Less Than 300 Mm Long, All Links Shall Be Insulated With Colour Coded Heat Shrinkable Sleeves And Supported Arms Dmc / Epoxy Insulators Having Provision For Termination Of Incommer And Outgoing Cables. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel Of Suitable Size, Duly Coated With Zinc Metal Coating. A Detachable Pre Drilled Gland Plate Of Thickness 3.15Mm Thick, Cold Zink Metal Coated Shall Be Provided With At The Bottom For Entry For Armoured Cable With Adequate Size Of Gland. Manufacturer Name Plate With Feeder Details And Danger Plate Shall Be Provided At Suitable Visible Place. 3 Mcb Sp For Protection Of Metering Shall Be Provided. N Note:- Cost Fo Taking Down Existing Cable Connection From Existing Unsv Lt Panel, Making New Termination Using New Lugs / Thimble, Necessary Execvation For Takible Ng Out Loop Etc Is Deemed To Be Included In Above Rate N ( Ii ) All Mccb Shall Have Ics=Icu=100%, Thermal Megnatic Release, 4 Pole, Adjustable Type Make L & T, Abb, Legrand For 32 A Mall Road N ( A ) Mccb , 4Pole , 250 Amp , 50Hz, 415 Volts 36 Ka, With Microprocessor Release Icu=36Ka & Ics=100% Icu With Adjustable Over Load Setting ( Minimum 80% To 100% ) Qty - 01 No. N ( B ) Busbar Minimum 1.5 Times Of Incomer :- 4 Nos ( Three For Phase And One For Neutral ) Made Of Copper Of Capacity Minimum 1.5 Times Of Incomer Noutgoing:- N ( A ) Mccb Capacity 100 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 03 Nos. N ( B ) Mccb Capacity 63 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 02 Nos. N ( C ) Mcb Capacity 40Amp, 2 Pole, 10 Ka - 02 Nos. Nmetering :- N ( A ) One No Digital Type Multi Function To Show 0-500 V Voltmeter With Selector Switch 0-800A Ammeter With Selector Switch, Kwh Meter And Set Of Cast Resin Cts 800 / 5A. N ( B ) Indicator Lamp Led Based With Lamp Holder - 03 Nos. N ( C ) Pcc Work For Grouting Of Feeder Pillar Box Complete 21 Supply, Installation, Testing And Commissioning Of Outdoor Type Lt Main Feeder Pillar ( Ip-55 ) Powder Coated With Structural Siemens Grey Ral 7032 Shall Be Factory Fabricated Cubicle Panel Board As Per Is / Iec 61439-1 & 2 ( Cpri Approved ) Rated For Short Circuit Rating Of 50 Ka, Front And Back Operable And Lockable By Keys From Both Sides Having Louvers And Air Vent, Gasket An Totally Vermin Proof Made Out Of 3.15 Mm Thick Crca Sheet Duly Compartmentalized For Incoming And Outgoing Copper Bus Bar Duly Insulated With Colour Coded Heat Shrinkable Sleeves And Mounted On Dmc / Epoxy Insulators ( Size Not Less Than 50Mmx50mm Conical Type At A Maximum Interval Of 500Mm ) Of Not Less Than 1.5 Times The Rating Of Main Incommer. The Incommer And All Outgoing Shall Have Extention Link Of Capacity 1.5 Times The Rating Of Individual Feeder. If The Size Of Incoming / Outgoing Cable Is More Than 120 Sqmm, Then The Extention Link Shall Not Be Less Than 300 Mm Long, All Links Shall Be Insulated With Colour Coded Heat Shrinkable Sleeves And Supported Arms Dmc / Epoxy Insulators Having Provision For Termination Of Incommer And Outgoing Cables. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel Of Suitable Size, Duly Coated With Zinc Metal Coating. A Detachable Pre Drilled Gland Plate Of Thickness 3.15Mm Thick, Cold Zink Metal Coated Shall Be Provided With At The Bottom For Entry For Armoured Cable With Adequate Size Of Gland. Manufacturer Name Plate With Feeder Details And Danger Plate Shall Be Provided At Suitable Visible Place. 3 Mcb Sp For Protection Of Metering Shall Be Provided. N Note:- Cost Fo Taking Down Existing Cable Connection From Existing Unsv Lt Panel, Making New Termination Using New Lugs / Thimble, Necessary Execvation For Takible Ng Out Loop Etc Is Deemed To Be Included In Above Rate N ( Ii ) All Mccb Shall Have Ics=Icu=100%, Thermal Megnatic Release, 4 Pole, Adjustable Type Make L & T, Abb, Legrand For Fmc Near Water Supply Installation N ( A ) Mccb , 4Pole , 200 Amp , 50Hz, 415 Volts 36 Ka, With Microprocessor Release Icu=36Ka & Ics=100% Icu With Adjustable Over Load Setting ( Minimum 80% To 100% ) Qty - 01 No. N ( B ) Busbar Minimum 1.5 Times Of Incomer :- 4 Nos ( Three For Phase And One For Neutral ) Made Of Copper Of Capacity Minimum 1.5 Times Of Incomer Noutgoing:- N ( A ) Mccb Capacity 100 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 03 Nos. N ( B ) Mcb Capacity 40Amp, 2 Pole, 10 Ka - 01 Nos. Nmetering :- N ( A ) One No Digital Type Multi Function To Show 0-500 V Voltmeter With Selector Switch 0-800A Ammeter With Selector Switch, Kwh Meter And Set Of Cast Resin Cts 800 / 5A. N ( B ) Indicator Lamp Led Based With Lamp Holder - 03 Nos. N ( C ) Pcc Work For Grouting Of Feeder Pillar Box Complete 22 Supply, Installation, Testing And Commissioning Of Outdoor Type Lt Main Feeder Pillar ( Ip-55 ) Powder Coated With Structural Siemens Grey Ral 7032 Shall Be Factory Fabricated Cubicle Panel Board As Per Is / Iec 61439-1 & 2 ( Cpri Approved ) Rated For Short Circuit Rating Of 50 Ka, Front And Back Operable And Lockable By Keys From Both Sides Having Louvers And Air Vent, Gasket An Totally Vermin Proof Made Out Of 3.15 Mm Thick Crca Sheet Duly Compartmentalized For Incoming And Outgoing Copper Bus Bar Duly Insulated With Colour Coded Heat Shrinkable Sleeves And Mounted On Dmc / Epoxy Insulators ( Size Not Less Than 50Mmx50mm Conical Type At A Maximum Interval Of 500Mm ) Of Not Less Than 1.5 Times The Rating Of Main Incommer. The Incommer And All Outgoing Shall Have Extention Link Of Capacity 1.5 Times The Rating Of Individual Feeder. If The Size Of Incoming / Outgoing Cable Is More Than 120 Sqmm, Then The Extention Link Shall Not Be Less Than 300 Mm Long, All Links Shall Be Insulated With Colour Coded Heat Shrinkable Sleeves And Supported Arms Dmc / Epoxy Insulators Having Provision For Termination Of Incommer And Outgoing Cables. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel. All Control Wires Shall Be Not Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied, Ferruled For Proper Identification And Crimpled With Adequate Size Of Lugs, The Cubicle Will Have A Bottom Support Of Channel Of Suitable Size, Duly Coated With Zinc Metal Coating. A Detachable Pre Drilled Gland Plate Of Thickness 3.15Mm Thick, Cold Zink Metal Coated Shall Be Provided With At The Bottom For Entry For Armoured Cable With Adequate Size Of Gland. Manufacturer Name Plate With Feeder Details And Danger Plate Shall Be Provided At Suitable Visible Place. 3 Mcb Sp For Protection Of Metering Shall Be Provided. Nnote:- Cost Fo Taking Down Existing Cable Connection From Existing Unsv Lt Panel, Making New Termination Using New Lugs / Thimble, Necessary Execvation For Takible Ng Out Loop Etc Is Deemed To Be Included In Above Rate N ( Ii ) All Mccb Shall Have Ics=Icu=100%, Thermal Megnatic Release, 4 Pole, Adjustable Type Make L & T, Abb, Legrand For Map Kb Line And Odf Old Nincoming:- N ( A ) Mccb , 4Pole , 630 Amp , 50Hz, 415 Volts 36 Ka, With Microprocessor Release Icu=36Ka & Ics=100% Icu With Adjustable Over Load Setting ( Minimum 80% To 100% ) Qty - 01 No. N ( B ) Busbar Minimum 1.5 Times Of Incomer :- 4 Nos ( Three For Phase And One For Neutral ) Made Of Copper Of Capacity Minimum 1.5 Times Of Incomer Noutgoing:- N ( A ) Mccb Capacity 160 Amp, 4 Pole, 415V, 50 C / S 25 Ka - 06 Nos. N ( B ) Mccb Capacity 40Amp, 4 Pole, 415V, 50 C / S 25 Ka - 01 Nos. N ( C ) Mcb Capacity 40Amp, 2 Pole, 10 Ka - 01 Nos. Nmetering:- N ( A ) One No Digital Type Multi Function To Show 0-500 V Voltmeter With Selector Switch 0-800A Ammeter With Selector Switch, Kwh Meter And Set Of Cast Resin Cts 800 / 5A. N ( B ) Indicator Lamp Led Based With Lamp Holder - 03 Nos. N ( C ) Pcc Work For Grouting Of Feeder Pillar Box Complete 23 Supplying And Fixing In Repair Mccb, 630 Amps, 4 Pole, 415 Volts, Ac Supply, Having Breaking Capacity Icu =Ics = 100% , 50 Ka Microprocessor Withtharmal Magnetic Release Complete All As Directed. Make Cat No 422075 Of Legrand Or Equivalent To Schiider / L & T 24 Supplying And Fixing In Repair Mccb, 400 Amps, 4 Pole, 415 Volts, Ac Supply, Having Breaking Capacity Icu =Ics = 100% , 36 Ka Microprocessor Withtharmal Magnetic Release Complete All As Directed. Make Cat No 422063 Of Legrand Or Equivalent To Schiider / L & T 25 Supplying And Fixing In Repair Mccb, 250 Amps, 4 Pole, 415 Volts, Ac Supply, Having Breaking Capacity Icu =Ics = 100% , 25 Ka Withtharmal Magnetic Release Complete All As Directed. Make Cat No 420219 Of Legrand Or Equivalent To Schiider / L & T 26 Supplying And Fixing In Repair Mccb, 200 Amps, 4 Pole, 415 Volts, Ac Supply, Having Breaking Capacity Icu =Ics = 100% , 25 Ka Withtharmal Magnetic Release Complete All As Directed. Make Cat No 420218 Of Legrand Or Equivalent To Schiider / L & T 27 Supplying And Fixing In Repair Mccb, 100 Amps, 4 Pole, 415 Volts, Ac Supply, Having Breaking Capacity Icu =Ics = 100% , 25 Ka Withtharmal Magnetic Release Complete All As Directed. Make Cat No 420055 Of Legrand Or Equivalent To Schiider / L & T 28 Surface Dressing In Soft / Loose Soil Not Exceeding 15 Cm Deep And Removing Excavated Material N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Complete All As Specified And Directed. 29 Trimming / Cutting / Chopping Of Tree Branches All Around Lt / Ht Over Conductor Upto Two Meter And Removing Excavated Material N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Complete All As Specified And Directed. 30 Releasing Tension Of Existing Oh Line, Of Acsr / Copper Conductor Or Gi Earth Wire Of Any Size / Type On Existing Oh Line Restretching Properly And Fixing On Existing Insulators On Oh Cross Arms Of Poles Including Disconnection Service Connection Street Light Fitting Etc And Reconnecting The Same After Restretching Complete All As Specified And Directed ( Each Conductor Will Be Measured Seperately ) 31 M&L / Fix In Repair For Fabrication Work For Guarding, Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding Bending Cold Or Hot, Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Including One Primer Coat Of Red Oxide And Two Coats Of Aluminium Paint, Complete All As Specified.Make Tata / Jindal / Sail 32 Supplying, Fixing, Stringing In Replacement Of Aluminum Conductor Steel Reinforced ( Acsr ) Including Binding Wire For Binding To Aluminum Conductor Properly On Insulators At Least 50Mm On Existing / New Pole Over Head Lines, Jumpring, Connection And Jointing And Testing Complete All As Specified And Directed. 33 S&F In Replacement On Pole Factory Made, Dust Proof, Vermin Proof , Out Door Type Polycarbonate Boxs Incl Mcb Spn 6 Amps, , Spn Bus Bar, Insulator, Gi Nut, Bolts And Washers And Aluminum Lugs Etc With And Including Fi Clamp Made Out Of 30 Mmx 3 Mm , Nut And Bolts Complete All As Specified And Directed. Make : Sintax / Hensal 34 S&F In Replacement Ms Busbar Chamber Factory Made Of Of 200 Amps 4 Way Including Electric Connection , Etc With And Including Fi Clamp Made Out Of 50 Mmx 3 Mm , Nut And Bolts Complete All As Specified And Directed. Make Havells Cat Pt No Ihbc020004 Or Equivalant To Legrand / Schieder

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Mar-2021 CHANGE IN DESCRIPTION Other 13-03-2021
2 13-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-03-2021
3 26-Mar-2021 CHANGE IN DATE Date 31-03-2021
4 07-Apr-2021 DATE CHANGE Date 27-04-2021
5 04-May-2021 DATE Date 10-05-2021
6 17-May-2021 CHANGE IN DESCRIPTION Date 25-05-2021
7 01-Jun-2021 DATE_CHANGE Date 14-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 58740.0 /-
Tender Value
INR 29.37 Lakhs /-