Repair/Maintenance Of Ht Distribution Network , Transformer , Vcbs And Other Miscellaneous Items At Cda/Dad , Pao ( Or ) Aoc , Pao ( Or ) Eme Complex And Etc At Dgqa Complex Under Ge ( Utility ) Secunderabad, Secunderabad-Telangana

Military Engineer Services-MES has published Repair/Maintenance Of Ht Distribution Network , Transformer , Vcbs And Other Miscellaneous Items At Cda/Dad , Pao ( Or ) Aoc , Pao ( Or ) Eme Complex And Etc At Dgqa Complex Under Ge ( Utility ) Secunderabad. Submission Date for this Tender is 13-03-2021. Transformer Supply Tenders in Secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

27011058
Corrigendum : Repair/Maintenance Of Ht Distribution Network , Transformer , Vcbs And Other Miscellaneous Items At Cda/Dad , Pao ( Or ) Aoc , Pao ( Or ) Eme Complex And Etc At Dgqa Complex Under Ge ( Utility ) Secunderabad
Open Tender
Indian
Telangana
Secunderabad
13-03-2021

Tender Details

Repair/Maintenance Of Ht Distribution Network , Transformer , Vcbs And Other Miscellaneous Items At Cda/Dad , Pao ( Or ) Aoc , Pao ( Or ) Eme Complex And Etc At Dgqa Complex Under Ge ( Utility ) Secunderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Feb-2021 Corrigndum ot ohters Other 06-03-2021
2 06-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
INR 39 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF HT DISTRIBUTION NETWORK, TRANSFORMER, VCBs & OTHER MISCELLANEOUS ITEMS AT CDA/DAD, PAO (OR) AOC, PAO (OR) EME COMPLEX & ETC AT DGQA COMPLEX UNDER GE (UTILITY) SECUNDERABAD
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for disconnecting the electric supply and servicing of 11 KV AB switches upto 400 Amps by disconnecting, overhauling, greasing and reassembling same in its existing position, testing & commissioning complete all as specified and directed \nNote: supply of worn out spares shall be measured and paid seperately under relevant items BI01010001010000000000000515BI0100001140 22 Each Job
2 2 Supply only Male contact or Moving contact blade heavy duty and high conductive metal assembly brass/Gun metal suitable for 11 KV AB switch including taking down old u/s item complete all as specified and directed BI01010001010000000000000515BI0100001141 11 Each
3 3 Supply only Female contact or fixed contact heavy duty and high conductive metal assembly brass/Gun metal suitable for 11 KV AB switch including taking down old u/s item complete all as specified and directed BI01010001010000000000000515BI0100001142 11 Each
4 4 Disconnecting the electric supply, taking down the old u/s Disc insulator and Supply & Fixing Disc insulator single disc 11 KV grade porcelain vitreous brown or green 145mm high and 255 mm dia complete all as specified and directed BI01010001010000000000000515BI0100001143 12 Each Job
5 5 Disconnecting the electric supply, taking down the old u/s pin type insulator and Supply & Fixing pin type insulator 11 KV grade porcelain vitreous brown or green insulator including one galvanised iron washer and one nut 150mm high and 150 mm dia including taking out old unserviceable one ccomplete all as specified and directed BI01010001010000000000000515BI0100001144 14 Each Job
6 6 Disconnecting the electric supply and taking down the broken unserviceable post top inculator and S&F post top porcelain insulator vitrous brown with GI clamp nuts bolts etc suitable for 11000 Volts grade working pressure complete all as specified and directed BI01010001010000000000000515BI0100001145 14 Each Job
7 7 M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed BI01010001010000000000000515BI0100001146 10 Each
8 8 M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed BI01010001010000000000000515BI0100001147 8 Each
9 9 M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed BI01010001010000000000000515BI0100001148 2 Each
10 10 M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed BI01010001010000000000000515BI0100001149 2 Each
11 11 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as specified and directed BI01010001010000000000000515BI0100001150 223.2 CUM
12 12 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose/hard/dense soil complete all as specified and directed BI01010001010000000000000515BI0100001151 135.6 CUM
13 13 Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed BI01010001010000000000000515BI0100001152 87.6 CUM
14 14 Supply and spreading of dry river sand in trenches/ transformer yard/ two pole structure yard for cable protectioncomplete all as specified and directed\nNote:- Punned thickness only shall be measured for payment purpose. BI01010001010000000000000515BI0100001153 57.6 CUM
15 15 M&L for laying un-reinforced precast c oncrete cable cover, class HV , type 1 with size of 300 mm X180mm X 40mm complete all as specified and directed BI01010001010000000000000515BI0100001154 3556 Each
16 16 Supply and lay GI tubing 100 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed\n BI01010001010000000000000515BI0100001155 54 RM
17 17 M&L for boring of horizontally holes under the road below 1.0 mtr from the road/hard surface by trenches techonology using ultra sound technique and inclduing necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50m from the site of work including supply & laying HDPE pipe up to 150 mm dia suitable for 0.4 MPA work pressure complete all as specified and directed \nNOTE: Average width of the Road is 20 mtrs BI01010001010000000000000515BI0100001156 42 RM
18 18 Supply and lay GI tubing 80 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed\n BI01010001010000000000000515BI0100001157 32 RM
19 19 Supply, lay, connect test and commissioning of 3 core, 95 Sqmm, 11000 Volts grade(Earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct including taking out unserviceable burnt out cablecomplete all as specified and directed\n BI01010001010000000000000515BI0100001158 320 RM
20 20 Supply, lay, connect test and commissioning of 3 core, 120 Sqmm, 11000 Volts grade (Earthed)XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct including taking out unserviceable burnt out cable complete all as specified and directed\n BI01010001010000000000000515BI0100001159 300 RM
21 21 M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion, complete all as specified and directed \nNote:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade. BI01010001010000000000000515BI0100001160 10 Each Job
22 22 M&L for Supply,test,erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-55,11 mtrs HT poles complete all as directed by Engr-in-Charge. \nNote:-(i)Crane charges for erection shall be deemed to be including in quoted rate.\n(ii) Earth work,PCC,coping shall be measured and paid separately.\n(iii) The rates include staying the poles in atruely vertical position till the foundations are properly set.\n(iv)The rates include cast iron base plate,nuts,bolts,screws,painting of steel tubular poles,drilling of holes in steel tubular poles for fixing of clamps,hooks for continuous earth wire/strip. BI01010001010000000000000515BI0100001161 6 Each Job
23 23 Supply, test, install & commissioning of HT 11 KV outdoor type gang operated air break switch triple pole mechanically operated suitable for horizontal or vertical mounting(suitable for existing one) on insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps and connecting up with jumpers, testing and commissioning including dismantling/disconnecting & taking down the old unserviceable one complete all as specified and directed\n BI01010001010000000000000515BI0100001162 4 CUM
24 24 M&L stay assembly comprising of MS stay plate 6 mm thick and of size 300 x 300 mm and 20 mm dia MS stay rod, 2150 mm long including thimbles GI stay strand 7/3.15 mm dia of required length complete all as shown on electrical plate No.1 on page No.495 of MES SSR Part-I 2009 including necessary excavation PCC 1:3:6 Type C2 (using 40mm graded stone aggregate), loop insulator as specified in SSR and including taking down old unserviceable one complete all as specified and directed BI01010001010000000000000515BI0100001163 4 Each Job
25 25 M&L of cross arm i.e., bracing supporting clamps back plates, nuts, bolts and washers complete including one under coat and one finishing coat with synthetic enamel paint over a coat of red oxide primer & including taking down old unserviceable complete all as specified and directed BI01010001010000000000000515BI0100001164 10 Qtl
26 26 Supply and install lightening arrestor expulsion type complete with all fittings transmission class, discharge capacity 65 Kilo Amps suitable for 11 KV connecting testing & including taking down old unserviceable complete all as specified and directed BI01010001010000000000000515BI0100001165 4 Set of three
27 27 M&L ACSR jumper in HT/LT over head line as that of existing size including binding wire, nuts & bolts washerscomplete all as specified and directed BI01010001010000000000000515BI0100001166 20 Each Job
28 28 M&L of danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white, with letters, figures and convention skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and directed BI01010001010000000000000515BI0100001167 20 Each Job
29 29 M&L for Cradles, hexagonal/rectangular fabricated with galvanised steel 4mm dia & including taking down old unserviceable complete all as specified and directed BI01010001010000000000000515BI0100001168 0.5 Qtl
30 30 M&L for ACSR conductor, steel reinforced for LT / HT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed. BI01010001010000000000000515BI0100001169 2 Qtl
31 31 M &L for Disconnection of all Primary/Secondary connections of the defective transformer rating up to 200kVA out door / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and test, install & commissioning in its original existing position by making all neccessary connections complete all as specified and directed\nNote :- Crane and Transporting Charges including in the Job. BI01010001010000000000000515BI0100001170 4 Each Job
32 32 M &L for Disconnection of all Primary/Secondary connections of the defective transformer rating above 200 KVA and up to 500kVA out door / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and test,install &commissioning in its original existing position by making all neccessary connections complete all as specified and directed\nNote :- Crane and Transporting Charges including in the Job. BI01010001010000000000000515BI0100001171 4 Each Job
33 33 M &L for Opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body,remove the sludge from tank complete and segregation of HT/LT leg coil from transformer including job assembling of jointing the connections pf HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber of as per IS Specification of respective transformer capacity for remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket ( Bushing and tank) etc and welding if any leakage found in body or fins, making good dificient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint aftre cleaning inside transformer tanks and two coats of outside painting including writing KVA Capacity, repairs of body by means of welding, jointing if required complete for capacity up to 200 KVA with complete Testing and Commissioning complete all as specified and directed BI01010001010000000000000515BI0100001172 4 Each Job
34 34 M &L for Opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body,remove the sludge from tank complete and segregation of HT/LT leg coil from transformer including job assembling of jointing the connections pf HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber of as per IS Specification of respective transformer capacity for remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket ( Bushing and tank) etc and welding if any leakage found in body or fins, making good dificient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint aftre cleaning inside transformer tanks and two coats of outside painting including writing KVA Capacity, repairs of body by means of welding, jointing if required complete for capacity above 200KVA and up to 500 KVA with complete Testing and Commissioning complete all as specified and directed BI01010001010000000000000515BI0100001173 4 Each Job
35 35 M&L for Making Primery/Secondary coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per specification of old existing transformer including making of coil as required of various capacity of transformer complete all as specified and directed BI01010001010000000000000515BI0100001174 1150 KG
36 36 M &L for Reconditioning of over heated HT/ LT coil of transformer up to 400 KVA after removing all old insulation any type and re-insulation as required and remaking of LT coil complete all as specified and directed BI01010001010000000000000515BI0100001175 700 KG
37 37 M&L for Opening of the 11 KV / 0.433 KV Distribution transformer rating up to 500 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level,check leaked cork seal(if any), check the un sericeable insulators & LT/HT bush (if any) complete from the shell and making connections of LT/HT bush,insulators & cork seals to avoid leakage and refilling oil back to existing postion into the transformer complete testing & commissioning complete all as specified and directed\nNote: Spares shall be measured and paid separately under relevant items BI01010001010000000000000515BI0100001176 8 Each Job
38 38 Supply and fixing of HT bushing including metal parts and washer complete for any make of transformer mounted on plinth/pole and transformer rating up to 500 KVA capacity complete including taking down old u/s one complete all as specified and directed BI01010001010000000000000515BI0100001177 18 Each
39 39 Supply and fixing of LT rod / studs for any make of transformer rating up to 500kVA mounted on pole/plinth, made of brass with nut and washers, Insulator and fittings etc as per size and shape of original complete including taking down old u/s one complete all as specified and directed BI01010001010000000000000515BI0100001178 24 Each
40 40 Supply and fixing Gasket set (crok sheet) for any make of transformer rating upto 400 KVA for top of transformer or conservator tank after decanning the required level of oil including taking down old u/s one complete all as specified and directed BI01010001010000000000000515BI0100001179 8 Each Set
41 41 M&L for Replacement of air breather with filled silica gel suitable for any make of tranformer rating up to 500 KVA mounted on plinth/pole including taking out old u/s onecomplete all as specified and directed BI01010001010000000000000515BI0100001180 8 Each Job
42 42 Supply and filling of transformer oil in transformer plinth / pole mounted including including testing insulation and vescocity of oil complete all as specified and directed\n BI01010001010000000000000515BI0100001181 1700 LTR
43 43 M &L for Dehydration including filtration cleaning of transformer oil in transformer indoor/ outdoor type by centrifusion / machine having minimum capacity 1000 to 30000 ltrs/ hrs including testing insulation and vescocity of oil before and after dehydration complete all as specified and directed BI01010001010000000000000515BI0100001182 5000 LTR
44 44 M &L for Shifting of the any make of transformer rating up to 500 KVA mounted onplinth/pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commission complete all as specified and directed\nNote:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer. BI01010001010000000000000515BI0100001183 2 Each Job
45 45 Dismantling HT/LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as specified and directed BI01010001010000000000000515BI0100001184 2 Each Job
46 46 Inspection of defective 11kv HT cable(laid in UG/trench/tunnel/wall/surafce) to locate the fault using cable fault Locator machine(by surge genarators munted on Van) (fault either by Short/Moisture/earth fault or any type)complete all as specified and directed BI01010001010000000000000515BI0100001185 2 Each Job
47 47 M&L for cleaning/ painting the HT poles of OH lines and HT four pole/ two pole structures complete with crossarms any height and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/ rust carefully and applying two coats of synthetic aluminium paint including marking and colour washing of pole coping complete all as specified and directed and details as are under:- BI01010001010000000000000515BI0100001186
48 47.01 (a) Two poles with crossarms BI01010001010000000000000515BI0100001187 8 Each Job
49 47.02 (b) Four poles with crossarms BI01010001010000000000000515BI0100001188 4 Each Job
50 47.03 (b) Six poles with crossarms BI01010001010000000000000515BI0100001189 2 Each Job
51 47.04 (c) HT 11 mtr single pole BI01010001010000000000000515BI0100001190 30 Each Job
52 48 M&L for Spray painting of upto 500 KVA transformer pole mounted / plinth mounted at site and applying two coat of synthetic enameled Smoke grey paint after removing all dust & rust and paint shall confirm to IS 2032 including marking or transformer capacity with stencil letter with black or white paint and Font and Size of letter shall be directed by Engr-in-Charge, complete all as specified and directed BI01010001010000000000000515BI0100001191 14 Each Job
53 49 Supply & laying cement concrete in foundation (1:4:8) type D2 using 40 mm graded broken stone aggregate including form work complete all as specified and directed BI01010001010000000000000515BI0100001192 3 CUM
54 50 Supply and laying PCC (1:3:6) type C1, using 20mm graded aggregate for coping of PCC pole 11 mtrs long complete all as specified and directed BI01010001010000000000000515BI0100001193 2 CUM
55 51 Supply and laying PCC (1:2:4) type B2, using 40mm size graded stone aggregate for foundation of PCC pole 11 mtrs long complete all as specified and directed BI01010001010000000000000515BI0100001194 4 CUM
56 52 Cutting anxious green growth / vegitation growth for cleaning out the area around transformer installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removel of the same by surface excavation not exceeding 30 cm deep average 15 cm complete all as specified and directed BI01010001010000000000000515BI0100001195 3500 SQM
57 53 Maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pauring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works to the PCC chambers and RCC cover with cement mortar 1 : 4 complete all as specified and directed BI01010001010000000000000515BI0100001196 20 Each Job
58 54 Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. \n BI01010001010000000000000515BI0100001197 2000 RM
59 55 Dismantling and taking out existing DO fuse unit 3 pole 11 KV channel mounted complete including supply and fix for new D O fuse unit 3 pole 11 KV channel mounted complete all as specified and directed BI01010001010000000000000515BI0100001198 6 Set of three
60 56 Cutting and trimming trees branches any girth and any size touching to overhead lines and cleaning the distance 1.5 mtr length both side of OH line with in a span of 35 mtrs each disposing the same, clearing the site complete all as specified and directed BI01010001010000000000000515BI0100001199 140 SPAN
61 57 Taking out and Relaying of HT 11 KV cable of size 95 sq mm to 150 Sqmm 3 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs complete all as specified and directed\nNote: (a) Earth work , sand Cushioning, brick protection, Joints shall be measured and paid separately under Relevent Item \n (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item BI01010001010000000000000515BI0100001200 200 RM
62 58 Relaying of serviceable bricks / pcc cover of any size retrived during taking out of HT cable complete all as directed BI01010001010000000000000515BI0100001201 600 RM
63 59 M&L for providing platform for transform of size 3.0x3.0x1m high from GL including excavation in trenches not less than 1mtr, PCC1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 on brick / complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:4:8 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, chain link fencing 1.8 m high made out of 4 mm dia GI wire 150x100mm mesh MS work angle iron 50x50x6mm as fencing post in embedded in brick /PCC work at 2mtr interval each side as approved 1 No steel gate (3.5m clear) span as shown in drawing with locking arrangement made out of 15mm dia MS rod & 50x50x6 mm angle iron frame, painting with 2 coat alu paint over a coat of red oxide primer and 3 coats of white washing on cement work including 02 Nos ISMB 100mm chanel for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and directed BI01010001010000000000000515BI0100001202 2 Each Job
64 60 Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out HARD / DENSE soil complete all as specified and directed BI01010001010000000000000515BI0100001203 200 SQM
65 61 M&Lfor shingle filling in floors or pavings of Gauge 40 to 63 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a True Surface, complete all as specified and as directed. BI01010001010000000000000515BI0100001204 50 CUM
66 62 M&L for preparation of old painted surface removing of rust from any kinf of steel surface ,clamps etc for of any description and repainting by 1st quality Synthetic enamelled paint 1 coat over a coat of primer complete all as specified and directed BI01010001010000000000000515BI0100001205 100 SQM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail