| 1 | 1.01 | DRILLING:- Drilling of bore hole of suitable diameter upto required depth by water jet system through any type of soil including hire and labour charges for boring pipes, scaffolding, other tools and plants etc. and taking out same all complete and other incidental works in this connection. The bore hole shouid have minimum 65 mm gap in between outside of the tube well pipe and bore . For lowering 100mm. dia PVC pipe | BI01010001010000000000000515BI0100001112 | 93 | mtr |
|---|
| 2 | 1.02 | For lowering 150mm. dia PVC pipe | BI01010001010000000000000515BI0100001113 | 60 | mtr |
|---|
| 3 | 2.01 | Labour charges for lowering of pipe, strainers, blank pipes etc. and fitting, fixing the same including cutting, threading where necessary complete including bucket washing and other incidental works in this connection. 100 mm dia UPVC Pipe with bottom cutter, Screen (Ribbed) pipes, blank pipe | BI01010001010000000000000515BI0100001114 | 90 | mtr |
|---|
| 4 | 2.02 | 150 mm dia UPVC Housing Pipe | BI01010001010000000000000515BI0100001115 | 60 | mtr |
|---|
| 5 | 3 | Supply of gravel for use as pack in the tube well of 2mm to 4mm size (As per IS:4097) and gravel treatment of tubewell including screening washing, cleaning etc. of the gravels at the site all complete as per direction of Engineer-in-Charge . | BI01010001010000000000000515BI0100001116 | 5 | Cum |
|---|
| 6 | 4.01 | Supplying, fitting and fixing including supplying of suitable jointing compound for fixing in position, threading, if necessary etc. all complete. 100 mm dia CI/Steel cutter piece upto 450 mm long with socket. | BI01010001010000000000000515BI0100001117 | 1 | each |
|---|
| 7 | 4.02 | 100 mm x 150 mm UPVC reducing socket . | BI01010001010000000000000515BI0100001118 | 1 | each |
|---|
| 8 | 4.03 | 150 mm dia GI threaded top cap fixed in position. | BI01010001010000000000000515BI0100001119 | 1 | each |
|---|
| 9 | 4.04 | 80 mm dia plug of approved make conforming to I.S. Specifications. | BI01010001010000000000000515BI0100001120 | 1 | each |
|---|
| 10 | 5 | Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete. | BI01010001010000000000000515BI0100001121 | 1 | each tube well |
|---|
| 11 | 6 | Making arrangement and showing verticality test including cost/hire charges of necessary tools and plants, scaffolding, labour etc. – all complete as per direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001122 | 1 | each tube well |
|---|
| 12 | 7 | Charges for mobilisation of drilling equipments, tools & plants etc and transportation of departmental materials from sub-divisional store to work site and returning excess departmental materials if any, to sub divisional store after completion of work . | BI01010001010000000000000515BI0100001123 | 1 | each tube well |
|---|
| 13 | 8 | Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive for all charges for equipments, labour, data aquisition and compilation of data sheets as per direction of the Engineer-in-Charge). | BI01010001010000000000000515BI0100001124 | 1 | each tube well |
|---|
| 14 | 9 | MATERIALS:- PVC pipes of nominal dia 100 mm , wall thickness 5.0 mm , conforming to IS : 12818/1997 (medium casing) . | BI01010001010000000000000515BI0100001125 | 78 | mtr |
|---|
| 15 | 10 | 150 mm nominal dia 7.5 mm wall thick PVC Casing (medium casing) pipes as per IS : 12818/1997. | BI01010001010000000000000515BI0100001126 | 60 | mtr |
|---|
| 16 | 11 | PVC Screen (Ribbed) Pipes of nominal dia 100 mm (O.D. 117 mm) , wall thickness 5.0 mm, conforming to IS : 12818/1997 . | BI01010001010000000000000515BI0100001127 | 12 | mtr |
|---|
| 17 | 12 | 3 Core 2.5 sqmm Flat Weather Proof Copper PVC insulated heavy cable as per IS Specification (Brimsin or of any other reputed brand as per direction of EIC) | BI01010001010000000000000515BI0100001128 | 60 | mtr |
|---|
| 18 | 13 | 80mm dia 6 mm thick heavy duty M S supporting clamp with 2 nos. 12 mm dia 65 mm long bolts, nuts, washer on each side for holding Column Pipe. | BI01010001010000000000000515BI0100001129 | 2 | Pair |
|---|
| 19 | 14 | Supplying 80 mm dia GI union with ISI mark. | BI01010001010000000000000515BI0100001130 | 1 | each |
|---|
| 20 | 15 | Supplying 80 mmx 50mm dia reducing TEE with ISI mark. | BI01010001010000000000000515BI0100001131 | 1 | each |
|---|
| 21 | 16 | Supplying 80 mm dia GI plain bend with ISI mark. | BI01010001010000000000000515BI0100001132 | 2 | each |
|---|
| 22 | 17 | Supplying fitting and fixing 40 mm dia PVC control valve as per approved make quality as direction by EIC. | BI01010001010000000000000515BI0100001133 | 1 | each |
|---|
| 23 | 18 | Supplying, fitting & fixing of M.S. plate of size 20 cm x 20 cm,thickness 6 mm, make of two halves (20cm x 10 cm), placed over Housing Pipe of LDTW to rest the supporting clamps, with semi circular hole of 90 mm dia. at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 25 mm dia. G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect. | BI01010001010000000000000515BI0100001134 | 1 | each set |
|---|
| 24 | 19 | Supply of lay flat hose of 75 mm nominal size polyster reinforced lay flat hose ( the hose should have wall thickness 1.3 mm workimg pressure 3.0 kg/sqm & brusting pressure 9 kg /sq m. The lay flat hose should have a standard length od 100 m roll. | BI01010001010000000000000515BI0100001135 | 100 | mtr |
|---|
| 25 | 20 | SOLAR:-Solar Module: Supply, transport, installation and commissioning of lSI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/ MonocrystaIIine/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/ 4.0 mm tempered glass, framed in anodized aluminium frame . The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances. Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. For 5 HP Off-grid Solar Water Pumping System with polycrystalline SPV modules. | BI01010001010000000000000515BI0100001136 | 5525 | Wp |
|---|
| 26 | 21 | Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply, transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 VVp SPV Module as per drawing and specification of MNRE. The steel structure is to be protected with minimum 80 micron galvanisation (hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. (Consider 6 Module structure; 3 sets; each set = 214.13 Kg.)\n | BI01010001010000000000000515BI0100001137 | 642.4 | Kg |
|---|
| 27 | 22 | Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing. For 6 module structure. | BI01010001010000000000000515BI0100001138 | 3 | each |
|---|
| 28 | 23 | Power conditioning unit with IP54 enclosure:\nSupply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard, safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol. It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission.For 5 HP capacity Pump-motor set. | BI01010001010000000000000515BI0100001139 | 1 | set |
|---|
| 29 | 24 | Cable and Accessories :\nSupplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. For 5 HP structure.\ni. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum)\nii. 6.0 Sq mm single core multi struds -5 Mtrs (Minimum)\niii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc. | BI01010001010000000000000515BI0100001140 | 3 | each |
|---|
| 30 | 25 | Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:\n (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.\n | BI01010001010000000000000515BI0100001141 | 3 | each set |
|---|
| 31 | 26 | a) Lighting System at Scheme: (with lighting Pole) :\nDawn to dusk light arrangement of 4 mts height with 75 mm x 50 mm G.I. pipe without lighting arm and with Solar Battery 12 V, 40 Ah (reputed brand- tubular type), Charge controller, 50 Wp solar panel, LED 11 watt 12 volt. Battery and Charge controller to be mounted on a kiosk box of thickness 14 swg, powder coated painted which is to be fitted at the bottom of the light post at man height. | BI01010001010000000000000515BI0100001142 | 1 | set |
|---|
| 32 | 27 | Lightning protection (Pole mounted): Lightning protection with 3\" X 1.5\" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works including Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure) | BI01010001010000000000000515BI0100001143 | 3 | set |
|---|
| 33 | 28 | Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.: (c) 5 HP ISI marked Pump-Motor set having discharge at required head as below: -ii) SubmersiblePump-motor set for lDTW lSImarked as per IS:8034 with discharge of 7.5 tps- 5.83 lps at 30 mts.- 40 mts. total head with cable, cover plate, Socket, Flanged Nipple, Rubber Insertion, Nuts& bolts and all otheraccessories including transportation of Bend, Column Pipes, cable, Sluice valve, lay flat hose pipe etc. from Deptt. Store to site within lOO km. | BI01010001010000000000000515BI0100001144 | 1 | set |
|---|
| 34 | 29 | Testing and commissioning of scheme after completion of all work | BI01010001010000000000000515BI0100001145 | 1 | Item |
|---|
| 35 | 30 | Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time (c) For 5HP both for Submersible & Surface pump. Note: Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ iii) Rs. 0.75 for 5 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e. at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited | BI01010001010000000000000515BI0100001146 | 5525 | Wp |
|---|
| 36 | 31 | CONSTRUCTION OF VAT:-Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. | BI01010001010000000000000515BI0100001147 | 0.62 | Cum |
|---|
| 37 | 32 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. | BI01010001010000000000000515BI0100001148 | 2.77 | m2 |
|---|
| 38 | 33 | Hire and labour charges for shuttering with 25 mm to 30 mm thick hard wood plank including fitting and fixing and striking out after completion of works. | BI01010001010000000000000515BI0100001149 | 1.33 | Sqm |
|---|
| 39 | 34 | Ordinary Cement Concrete (1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, as per relevent IS codes. With local hard blackstone varieti chips . | BI01010001010000000000000515BI0100001150 | 0.42 | Cum |
|---|
| 40 | 35 | Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction . Tor steel. | BI01010001010000000000000515BI0100001151 | 0.03 | MT |
|---|
| 41 | 36 | 65 mm thick1.2 m internal diameter R.C.C ring made with cement concrete 1:1.5:3 with stone chips and 0.80 % reinforcement (including the cost of shuttering and reinforcement ) cast at site fitted and fixed in position after proper curing true to plumb including jointing with cement motor 1: 2 complete as per direction. | BI01010001010000000000000515BI0100001152 | 2.1 | mtr |
|---|
| 42 | 37 | Supplying fitting and fixing 80 mm dia medium quality GI pipes as per IS specification with all necessary accssories, special viz. socket, bend, tee,flange etc. fitted with holder bats clamps, including cutting pipes , making threas, fitting fixing with necessary nuts & bolts, rubber insertions etc. complete in all respect including cost of all necessary fittings as required and as per drawing & specification and as per direction of EIC. | BI01010001010000000000000515BI0100001153 | 0.9 | mtr |
|---|
| 43 | 38 | Supplying fitting and fixing 75 mm dia PVC control valve as per approved make quality as direction by EIC. | BI01010001010000000000000515BI0100001154 | 3 | each |
|---|
| 44 | 39 | Colour washing with any shade with stainers, as required including cleaning and smoothening surface throughly.(ii) External surface (b) Two coats (ii) yellow/pink. | BI01010001010000000000000515BI0100001155 | 5.82 | Sqm |
|---|
| 45 | 40 | MAKING COLUMN PIPE:- Labour charges for loading of 80 mm dia GI Pipe into trucks, carts, boats etc. at lifting point and unloading the materials at the destination and stacking the same as per direction including carriage by head load upto a lead of 100 metres at each end.(To & Fro). | BI01010001010000000000000515BI0100001156 | 84 | mtr |
|---|
| 46 | 41 | Carriage of 80 mm dia GI Pipe over pucca road upto 5 km distance.(To & fro). | BI01010001010000000000000515BI0100001157 | 84 | mtr |
|---|
| 47 | 42 | Cutting out & threading 80 mm GI Pipe | BI01010001010000000000000515BI0100001158 | 28 | each |
|---|
| 48 | 43 | Labour charges for fitting & fixing of 80 mm dia GI Socket . | BI01010001010000000000000515BI0100001159 | 14 | each |
|---|
| 49 | 44 | Supply of 80 mm dia GI Socket with ISI Mark. | BI01010001010000000000000515BI0100001160 | 14 | each |
|---|
| 50 | 45 | G. S. T. @ 18% on only for Materials cost. SL NO.9 to 19 & 44 | BI01010001010000000000000515BI0100001161 | 102347 | eighteen percent |
|---|
| 51 | 46 | G. S. T. @ 12% on only for works cost.Sl. No. \n1 to 8 & 20 to 43 | BI01010001010000000000000515BI0100001162 | 510362 | twelve percent |
|---|
| 52 | 47 | Add Labour well fare Cess @1% . | BI01010001010000000000000515BI0100001163 | 692374 | one percent |
|---|