| 1 | 1 | Construction of first floor | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.001 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | BI01010001010000000000000515BI0100001114 | 0.6 | cum |
|---|
| 3 | 1.002 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001115 | 0.6 | cum |
|---|
| 4 | 1.003 | 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | BI01010001010000000000000515BI0100001116 | 1113.91 | kg |
|---|
| 5 | 1.004 | 15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | BI01010001010000000000000515BI0100001117 | 0.504 | cum |
|---|
| 6 | 1.005 | 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001118 | 0.42 | cum |
|---|
| 7 | 1.006 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | BI01010001010000000000000515BI0100001119 | 5.965 | sqm |
|---|
| 8 | 1.007 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001120 | 37.8 | kilogram |
|---|
| 9 | 1.008 | od957055/2020_2021 : Laterite masonry with neatly dressed laterite stone of size 35x20x20 cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including cost of materials labour charges etc. | BI01010001010000000000000515BI0100001121 | 27.24 | cum |
|---|
| 10 | 1.009 | od1018183/2020_2021 : Providing trafford Alu Zinc sheet roofing including vertical/curved surface fixed with self drilling/self tapping screws with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.40 mm thick Alu Zinc sheet trafford | BI01010001010000000000000515BI0100001122 | 139.2 | sqm |
|---|
| 11 | 1.01 | od1092650/2020_2021 : Providing ridges or hips of width 60 cm over all width plain Alu-Zinc sheet fixed with self drilling/self tapping screws, G.I. limpet and bitumen washers, etc. complete. | BI01010001010000000000000515BI0100001123 | 5.2 | metre |
|---|
| 12 | 1.011 | od1020041/2020_2021 : providing and fixing200mm split pipe over flat iron brackets 20x5mm size | BI01010001010000000000000515BI0100001124 | 10.4 | metre |
|---|
| 13 | 1.012 | 50.18.9.17.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall | BI01010001010000000000000515BI0100001125 | 12.4 | metre |
|---|
| 14 | 1.013 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001126 | 264.6 | sqm |
|---|
| 15 | 1.014 | 50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | BI01010001010000000000000515BI0100001127 | 0.045 | cum |
|---|
| 16 | 1.015 | 50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001128 | 1.83 | sqm |
|---|
| 17 | 1.016 | 50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | BI01010001010000000000000515BI0100001129 | 1.007 | sqm |
|---|
| 18 | 1.017 | 9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001130 | 4 | each |
|---|
| 19 | 1.018 | 9.66.1 : Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:125 mm | BI01010001010000000000000515BI0100001131 | 2 | no |
|---|
| 20 | 1.019 | 9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm | BI01010001010000000000000515BI0100001132 | 2 | no |
|---|
| 21 | 1.02 | 50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop | BI01010001010000000000000515BI0100001133 | 1 | no |
|---|
| 22 | 1.021 | 21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001134 | 27.2 | kg |
|---|
| 23 | 1.022 | 21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001135 | 9.462 | kg |
|---|
| 24 | 1.023 | 21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness | BI01010001010000000000000515BI0100001136 | 9.543 | sqm |
|---|