| 1 | 1 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in-charge.\nThe glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments). | | 2.5 | sqm |
|---|
| 2 | 2 | Providing and Fixing Metal Fire door complete with frame factory made from ISO 9001:2015 certified Manufacturer As per NBC 2016 Part 4 for Fire & Life Safety . The door must have been manufactured with galvanised - GI sheet. All Fire doors must satisfy the requirement of latest NBC 2016 Part 4 for Fire & Life Safety guidelines for 120 minutes Fire Rating with minimum 20 minutes Insulation properties along with its Stability & Integrity for 120 minutes. The Prototype sample of the door must carry a prior test evidence as per IS 3614 part-2 /BS 476 Part 20 & 22 , The manufacturer must submit the copy of test evidence prior to start of production .The offered test certificate should either carries it's Validity & certificate must not be older than 5 years from CBRI / NABL Accreditated Lab i.e Spectre/ International Lab l.e Exova I TBW etc . | | | |
|---|
| 3 | 2.1 | Recommended fire door must also been certified by a third party evaluation program from approved International agency like IFC/ Intertek/ Certifire arrd must carry a lable on all doors . All doors with Frame should be finished with Powder coating not less than 30 micron In desired regular RAL Shades.Door frame shall be Single rebate profile of section 100 x 57 mm made out of 1.20 mm thick galvanised steel sheet with a factory pre- punched groove so as to accomodate Fire & smoke seal size 10x4mm. Frames should be butt jointed and field assembled with bolting system for proper strength. Frames should be provided with back plate for G.I. anchor fasteners for installation on a finished plastered wall opening. The Air gap between Wall and frame can be filled with fire retardant sealant (payable in extra item).Door leaf should be minimum 46mm thick fully flush double skin door. Door leaf must be manufactured from 0.8 mm thick galvanised steel sheet.The door should be provided with reinforcement pads to receiving appropriate Hardwares of Becker Fire Solutions or Equivalent make. The frame and Shutter shall be filled with proprietary infill material i.e. mineral wool Insulation having minimun density of 96 kg/cum) . For Double leaf doors; astragal has to be provided on meeting stile for both active and inactive leaf. Vision panels wherever required should be of 120 minutes fire rating and should be of non-wired type. ( All hardwares i.e G.I. Anchor Fasteners, fire tetardent sealant and FR Glass etc. shall be payable In Extra item.) | | 77 | sqm |
|---|
| 4 | 3 | Providing and fixing Becker fire solutiopn or eqv. make stainless steel Ball bearing hinges (heavy weight) with stainless steel screws etc. complete : | | | |
|---|
| 5 | 3.1 | 100x75x3.00 mm | | 148 | nos |
|---|
| 6 | 4 | Providing and fixing Fisher or eqv. make carbon steel galvanised ( minimum coating 5 micron) Anchor fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. | | 266 | nos |
|---|
| 7 | 5 | Providing and fixing becker fire solutions or eqv. make universal hydraulic door closer (having brand logo, embossed on the body, door weight upto 80 kg and door width upto 900 mm), with necessary accessories and screws etc. complete. | | 37 | Nos |
|---|
| 8 | 6 | Providing and fixing panic bar / latch (Triple point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of becker fire solution or eqv brand and manufacture to be approved by the Engineer- in- charge, all complete. | | 18 | Nos |
|---|
| 9 | 7 | Providing and fixing panic trim of becker fire solution or eqv brand and manufacture to be approved by the Engineer- in- charge, all complete | | 18 | Nos |
|---|
| 10 | 8 | Providing and fixing becker fire solutions make dead lock with necessary screws etc. complete : | | 1 | Nos |
|---|
| 11 | 9 | Providing and fixing bright /matt finished becker fire solutions or eqv. Make Stainless Steel handles of approved quality & make with necessary screws etc all complete. | | | |
|---|
| 12 | 9.1 | 300x19 mm | | 1 | Nos |
|---|
| 13 | 10 | Add Cost Index @15.85% on DSR items on Rs. 85147/- | item133 | 85147 | Cum |
|---|
| 14 | 11 | Less @9.50% on DSR items as per Delhi Govt. Circular as per Govt. Delhi circular No. F. 8(2) /2007 AC/Finance/01295543/1376-1499 dt. 14.05.2018 | item134 | 85147 | Cum |
|---|