| 1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | item1 | 524.94 | Cum |
|---|
| 2 | 2 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | item2 | 1014.28 | Sqm |
|---|
| 3 | 3 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volume | item3 | 26.24 | cum |
|---|
| 4 | 4 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement bars | item4 | 240 | Qtl |
|---|
| 5 | 5 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plank | item5 | 233.28 | Sqm |
|---|
| 6 | 6 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nSides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plank | item6 | 275.52 | Sqm |
|---|
| 7 | 7 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut\n(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face.\n(ii) Using 25mm thick plank | item7 | 408.24 | Sqm |
|---|
| 8 | 8 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nSides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M.\n(ii) Using 25mm thick plank | item8 | 354.23 | Sqm |
|---|
| 9 | 9 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFlat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness.\n(ii) Using 25mm thick plank | item9 | 277.65 | Sqm |
|---|
| 10 | 10 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | item10 | 150.67 | cum |
|---|
| 11 | 11 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(B) In super structure from plinth level up to 1st floor level. \n(I) Using Mixer Machine\nii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | item11 | 165.55 | cum |
|---|
| 12 | 12 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4. | item12 | 104.36 | Cum |
|---|
| 13 | 13 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | item13 | 59.82 | sqm |
|---|
| 14 | 14 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | item14 | 480.6 | Cum |
|---|
| 15 | 15 | Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(b) Other than Guwahati city | item15 | 2025 | Cum |
|---|
| 16 | 16 | Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | item16 | 534 | Sqm |
|---|
| 17 | 17 | Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).\n(b) 1.60mm thick sheet\n(i) Size 90mm x 60mm (Single rebate) | item17 | 75.6 | M |
|---|
| 18 | 18 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | item18 | 749.5 | Sqm |
|---|
| 19 | 19 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\nb) In cement mortar 1:4\n | item19 | 1407.6 | Sqm |
|---|
| 20 | 20 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side b) In cement mortar 1:4 | item20 | 1407.6 | Sqm |
|---|
| 21 | 21 | 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. | item21 | 534 | Sq.m |
|---|
| 22 | 22 | Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(a)2 Track sliding window\n(i)6mm clear glass | item22 | 73.82 | Sqm |
|---|
| 23 | 23 | Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) \nB) With 1st class local wood \n(Gamari/Hollock/Bonsum ) (i) 40 mm thick. | item23 | 35.28 | Sq.m. |
|---|
| 24 | 24 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nI . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C. | item24 | 1292 | Kg |
|---|
| 25 | 25 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\na) Sliding door bolts\ni) 300mm x 16mm | item25 | 14 | Each |
|---|
| 26 | 26 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\nb) Tower bolts\nii) 250mm x 10mm | item26 | 28 | Each |
|---|
| 27 | 27 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\nc) Door handles iii) 150mm | item27 | 28 | Each |
|---|
| 28 | 28 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\nv) Door stopper with rubber stopper | item28 | 14 | Each |
|---|
| 29 | 29 | Chequered Terrazo tiles of 22 mm thickness with marble chips of sizes up to 6 mm fixed on wall with 10 mm thick bed of cement plaster in proportion 1:3 (1 cement : 3 coarse sand) jointed with neat white cement slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete with tiles of any approved shade/shades. \n(a) Using white cement | item29 | 90 | Sq.m |
|---|
| 30 | 30 | Providing and fixing stainless Steel (Grade 304) railing made of Hollow tubes, channels,plates etc. including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge. (For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered) | item30 | 227 | kg |
|---|
| 31 | 31 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick | item31 | 2815.2 | Sqm |
|---|
| 32 | 32 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | item32 | 1407.6 | Sqm |
|---|
| 33 | 33 | Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | item33 | 1407.6 | Sqm |
|---|
| 34 | 34 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer. | item34 | 73.82 | Sqm |
|---|
| 35 | 35 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | item35 | 73.82 | Sqm |
|---|
| 36 | 36 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white). | item36 | 70.56 | Sqm |
|---|
| 37 | 37 | Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | item37 | 70.56 | Sqm |
|---|
| 38 | 38 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | item38 | 99.6 | Sqm |
|---|
| 39 | 39 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\nii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. | item39 | 127.24 | Rm |
|---|
| 40 | 40 | Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt.\n Short point up to 3.00 metre. length. | item40 | 30 | Each |
|---|
| 41 | 41 | Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt.\n Medium point up to 6.00 metre. Length. | item41 | 28 | Each |
|---|
| 42 | 42 | Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt.\nLong point up to 10.00 metre. Length. | item42 | 33 | Each |
|---|
| 43 | 43 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system. | item43 | 250 | Metre. |
|---|
| 44 | 44 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.\nWith 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system. | item44 | 80 | Metre. |
|---|
| 45 | 45 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.\nWith 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system. | item45 | 60 | Metre. |
|---|
| 46 | 46 | Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin of the socket as required on the switch board in flat ISI marked casing 'n' capping system, when fitted on same board of light and fan. | item46 | 16 | Each |
|---|
| 47 | 47 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete.\nMedium point up to 6.00 metre. Length.\n | item47 | 9 | Each |
|---|
| 48 | 48 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete.\nLong point up to 10.00 metre. Length. | item48 | 6 | Each |
|---|
| 49 | 49 | Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp | item49 | 24 | Each |
|---|
| 50 | 50 | Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. | item50 | 24 | Each |
|---|
| 51 | 51 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make) 8 way SPN double door | item51 | 2 | Each |
|---|
| 52 | 52 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series\n(Schneider MG, legrand, Hager make) 6 to 32A | item52 | 12 | Each |
|---|
| 53 | 53 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n63A | item53 | 2 | Each |
|---|
| 54 | 54 | Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | item54 | 2 | Each |
|---|
| 55 | 55 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | item55 | 2 | Each |
|---|
| 56 | 56 | Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | item56 | 20 | Metre. |
|---|
| 57 | 57 | Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].\n Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make) | item57 | 38 | Each |
|---|
| 58 | 58 | Supplying fitting and fixing of celing fan regulator including connections etc. complete as required\nElectronic Type | item58 | 38 | Each |
|---|
| 59 | 59 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\n Power Flow 225 mm sweep (ORIENT make) | item59 | 4 | Each |
|---|
| 60 | 60 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | item60 | 25 | Each |
|---|
| 61 | 61 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | item61 | 60 | Metre |
|---|