Uttar Pradesh Projects Corporation Limited has published Construction Of Proposed Poultry Shed , Implement Shed ( Egg Production ) And Miscellaneous Civil Work For Krishi Vigyan Kendra At Distt-Mau. Submission Date for this Tender is 11-02-2021. Shed Construction Tenders in MAU Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work:CONSTRUCTION OF PROPOSED POULTRY SHED, IMPLEMENT SHED [EGG PRODUCTION] AND MISCELLANEOUS CIVIL WORK FOR KRISHI VIGYAN KENDRA AT DISTT-MAU [U.P.] | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | POULTRY SHED & NURSERY FOR CHICKS | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. | BI01010001010000000000000515BI0100001113 | 49.02 | CUM |
3 | 3 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | BI01010001010000000000000515BI0100001114 | 15.63 | CUM |
4 | 4 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. | BI01010001010000000000000515BI0100001115 | ||
5 | 5 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm | BI01010001010000000000000515BI0100001116 | ||
6 | 6 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. | BI01010001010000000000000515BI0100001117 | 68.717 | SQM |
7 | 7 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. | BI01010001010000000000000515BI0100001118 | 10.77 | CUM |
8 | 8 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate\n12.5mm nominal size) | BI01010001010000000000000515BI0100001119 | 6.82 | SQM |
9 | 9 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. | BI01010001010000000000000515BI0100001120 | 6.82 | SQM |
10 | 10 | Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) | BI01010001010000000000000515BI0100001121 | ||
11 | 11 | Ground Floor | BI01010001010000000000000515BI0100001122 | 26.48 | CUM |
12 | 12 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in FOOTING excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001123 | 6.37 | CUM |
13 | 13 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in BEAM excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001124 | 8.04 | CUM |
14 | 14 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in COLUMN excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001125 | 7.24 | CUM |
15 | 15 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in SLAB excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001126 | 8.87 | CUM |
16 | 16 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | BI01010001010000000000000515BI0100001127 | 34.37 | QTL. |
17 | 17 | 15 mm cement plaster on rough side of single or half brick wall of mix: (1 cement :4 coarse sand) | BI01010001010000000000000515BI0100001128 | 9.93 | SQM |
18 | 18 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand | BI01010001010000000000000515BI0100001129 | ||
19 | 19 | Ground Floor | BI01010001010000000000000515BI0100001130 | 116.98 | SQM |
20 | 20 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 fine sand. | BI01010001010000000000000515BI0100001131 | 96.28 | SQM |
21 | 21 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). | BI01010001010000000000000515BI0100001132 | 64.51 | SQM |
22 | 22 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001133 | 536.54 | KG |
23 | 23 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). | BI01010001010000000000000515BI0100001134 | 96.28 | SQM |
24 | 24 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For ceiling) | BI01010001010000000000000515BI0100001135 | 116.98 | SQM |
25 | 25 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001136 | 129.56 | Sqm |
26 | 26 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001137 | 834.31 | KG |
27 | 27 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the\ncost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. | BI01010001010000000000000515BI0100001138 | 77.484 | SQM |
28 | 28 | Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40\nsquare decimeter for chimney stacks, skylights etc. | BI01010001010000000000000515BI0100001139 | 7 | RM |
29 | 29 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with\nsuitable fixing accessories or self drilling fastener and EPDM washer etc. complete. | BI01010001010000000000000515BI0100001140 | 9.38 | RM |
30 | 30 | Providing and fixing of casing system Directed by Engineerin- charge. & plumbing C.P.V.C pipe distribution,nozel system required completion of work | BI01010001010000000000000515BI0100001141 | 603 | Nos |
31 | 31 | Internal electrical work | BI01010001010000000000000515BI0100001142 | ||
32 | 32 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. | BI01010001010000000000000515BI0100001143 | 9 | Each |
33 | 33 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. | BI01010001010000000000000515BI0100001144 | 6 | Each |
34 | 34 | Supply and wiring of submain with two number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 20 mm dia. heavy duty (2 mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. | BI01010001010000000000000515BI0100001145 | 25 | Metre |
35 | 35 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. | BI01010001010000000000000515BI0100001146 | ||
36 | 36 | 1 X 22 W CAT-AAA | BI01010001010000000000000515BI0100001147 | 9 | Each |
37 | 37 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. | BI01010001010000000000000515BI0100001148 | ||
38 | 38 | BEE 5 Star rated-1200mm sweep | BI01010001010000000000000515BI0100001149 | 6 | Each |
39 | 39 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve | BI01010001010000000000000515BI0100001150 | ||
40 | 40 | 6 - 32 amps.Cat. A | BI01010001010000000000000515BI0100001151 | 2 | Each |
41 | 41 | Supply and fixing of 6 Amp to 32 Amp DP MCB(10KA)C Curve | BI01010001010000000000000515BI0100001152 | ||
42 | 42 | 25 Amp. DP MCB(10KA) C Curve-Cat. A | BI01010001010000000000000515BI0100001153 | 1 | Each |
43 | 43 | Supply and fixing of flush/surface mounting distribution boards with additional metal door without MCB complete in all respects. | BI01010001010000000000000515BI0100001154 | ||
44 | 44 | 8 Way SPN Cat. B | BI01010001010000000000000515BI0100001155 | 1 | Each |
45 | 45 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. | BI01010001010000000000000515BI0100001156 | 8 | Each |
46 | 46 | Supply and fixing of single pole MCB blanking plate | BI01010001010000000000000515BI0100001157 | ||
47 | 47 | CAT A | BI01010001010000000000000515BI0100001158 | 4 | Each |
48 | 48 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. | BI01010001010000000000000515BI0100001159 | 6 | Each |
49 | 49 | Supply & fixing of cross clamp of required size fabricated from 50mm x 12mm M.S. flat complete with fan hook including painting etc. complete in all respects. | BI01010001010000000000000515BI0100001160 | 6 | Each |
50 | 50 | Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. | BI01010001010000000000000515BI0100001161 | 6 | Each |
51 | 51 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. \n6 sqmm 2 core | BI01010001010000000000000515BI0100001162 | 25 | Metre |
52 | 52 | NURSERY FOR CHICKS | BI01010001010000000000000515BI0100001163 | ||
53 | 53 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. | BI01010001010000000000000515BI0100001164 | 22.98 | CUM |
54 | 54 | Filling of carted earth. | BI01010001010000000000000515BI0100001165 | 10.57 | CUM |
55 | 55 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | BI01010001010000000000000515BI0100001166 | 14.23 | CUM |
56 | 56 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. | BI01010001010000000000000515BI0100001167 | ||
57 | 57 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm | BI01010001010000000000000515BI0100001168 | ||
58 | 58 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. | BI01010001010000000000000515BI0100001169 | 41.732 | SQM |
59 | 59 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. | BI01010001010000000000000515BI0100001170 | 9.64 | CUM |
60 | 60 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. | BI01010001010000000000000515BI0100001171 | 5.14 | SQM |
61 | 61 | Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) | BI01010001010000000000000515BI0100001172 | ||
62 | 62 | Ground Floor | BI01010001010000000000000515BI0100001173 | 6.31 | CUM |
63 | 63 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in FOOTING excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001174 | 0.94 | CUM |
64 | 64 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. | BI01010001010000000000000515BI0100001175 | 1.68 | CUM |
65 | 65 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in COLUMN excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001176 | 0.51 | CUM |
66 | 66 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | BI01010001010000000000000515BI0100001177 | 2.86 | QTL. |
67 | 67 | 15 mm cement plaster on rough side of single or half brick wall of mix: (1 cement :4 coarse sand) | BI01010001010000000000000515BI0100001178 | 7.48 | SQM |
68 | 68 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand | BI01010001010000000000000515BI0100001179 | ||
69 | 69 | Ground Floor | BI01010001010000000000000515BI0100001180 | 26.64 | SQM |
70 | 70 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 fine sand. | BI01010001010000000000000515BI0100001181 | 77.52 | SQM |
71 | 71 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). | BI01010001010000000000000515BI0100001182 | 36 | SQM |
72 | 72 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001183 | 557.28 | KG |
73 | 73 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). | BI01010001010000000000000515BI0100001184 | 77.52 | SQM |
74 | 74 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For ceiling) | BI01010001010000000000000515BI0100001185 | 26.64 | SQM |
75 | 75 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001186 | 39.85 | Sqm |
76 | 76 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001187 | 236.21 | KG |
77 | 77 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the\ncost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. | BI01010001010000000000000515BI0100001188 | 39.6 | SQM |
78 | 78 | Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40\nsquare decimeter for chimney stacks, skylights etc. | BI01010001010000000000000515BI0100001189 | 6 | RM |
79 | 79 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with\nsuitable fixing accessories or self drilling fastener and EPDM washer etc. complete. | BI01010001010000000000000515BI0100001190 | 6 | RM |
80 | 80 | electrical work | BI01010001010000000000000515BI0100001191 | ||
81 | 81 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash. | BI01010001010000000000000515BI0100001192 | 2 | each |
82 | 82 | Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001193 | 2 | each |
83 | 83 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001194 | 1 | each |
84 | 84 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable,with 5 amp flush type switch and 3 pin socket on existing board ,complete with 1.5 sq mm FRLSH PVC insulated multistrand copper conductor cable as earth wire.etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001195 | 1 | each |
85 | 85 | Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1 no. 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001196 | 4 | rmt |
86 | 86 | Supply & wiring of submains with 2 nos.6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with1 no. 4 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001197 | 10 | rmt |
87 | 87 | Supply and fixing of 40 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. | BI01010001010000000000000515BI0100001198 | 2 | each |
88 | 88 | Supply & fixing of Batton/Angle holder including making connection etc. as required. | BI01010001010000000000000515BI0100001199 | 2 | each |
89 | 89 | Supply and fixing of recess/surface/pendent mounting round 6 to 8 W LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001200 | 3 | each |
90 | 90 | Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube light Complete including tube etc on surface complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001201 | 2 | each |
91 | 91 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size | BI01010001010000000000000515BI0100001202 | ||
92 | 92 | size 10 sq mm x 2 core | BI01010001010000000000000515BI0100001203 | 5 | rmt |
93 | 93 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable | BI01010001010000000000000515BI0100001204 | ||
94 | 94 | size 10 sq mm x 2 core | BI01010001010000000000000515BI0100001205 | 4 | each |
95 | 95 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable | BI01010001010000000000000515BI0100001206 | ||
96 | 96 | size 10 sq mm | BI01010001010000000000000515BI0100001207 | 4 | each |
97 | 97 | Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A | BI01010001010000000000000515BI0100001208 | 1 | each |
98 | 98 | Supply and fixing of flush/surface mounting 8 ways SPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A | BI01010001010000000000000515BI0100001209 | 1 | each |
99 | 99 | Supply & Fixing of MCB blanking plate for DB. | BI01010001010000000000000515BI0100001210 | 1 | each |
100 | 100 | Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. | BI01010001010000000000000515BI0100001211 | 1 | each |
101 | 101 | Supply & Fixing of Moduler switch blanking plate for Moduler switch board. | BI01010001010000000000000515BI0100001212 | 2 | each |
102 | 102 | Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. | BI01010001010000000000000515BI0100001213 | ||
103 | 103 | 3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001214 | 2 | each |
104 | 104 | 6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001215 | 1 | each |
105 | 105 | Supply & Fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (light Duty) with blades,cover etc. complete as required | BI01010001010000000000000515BI0100001216 | 2 | each |
106 | 106 | Plumbing work | BI01010001010000000000000515BI0100001217 | ||
107 | 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. | BI01010001010000000000000515BI0100001218 | ||
108 | 108 | Concealed work including cutting chases and making good the walls etc. | BI01010001010000000000000515BI0100001219 | ||
109 | 109 | 15mm dia nominal outer dia pipes | BI01010001010000000000000515BI0100001220 | 8 | Metre |
110 | 110 | 20mm dia nominal outer dia pipes | BI01010001010000000000000515BI0100001221 | 4 | Metre |
111 | 111 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. | BI01010001010000000000000515BI0100001222 | ||
112 | 112 | a) 15mm nominal bore | BI01010001010000000000000515BI0100001223 | 2 | Each |
113 | 113 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 | BI01010001010000000000000515BI0100001224 | ||
114 | 114 | a) 15mm nominal bore | BI01010001010000000000000515BI0100001225 | 2 | Each |
115 | 115 | Providing and fixing gun metal gate valve with wheel of approved quality. | BI01010001010000000000000515BI0100001226 | ||
116 | 116 | 25mm dia nominal bore | BI01010001010000000000000515BI0100001227 | 1 | Each |
117 | 117 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete | BI01010001010000000000000515BI0100001228 | ||
118 | 118 | 25 mm nominal bore | BI01010001010000000000000515BI0100001229 | 1 | Each |
119 | 119 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | BI01010001010000000000000515BI0100001230 | 100 | Per Ltrs |
120 | 120 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design | BI01010001010000000000000515BI0100001231 | ||
121 | 121 | 150 x 100 mm. size P type | BI01010001010000000000000515BI0100001232 | ||
122 | 122 | With Sewer bricks conforming to IS : 4885 | BI01010001010000000000000515BI0100001233 | 1 | Each |
123 | 123 | IMPLEMENT SHED | BI01010001010000000000000515BI0100001234 | ||
124 | 124 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. | BI01010001010000000000000515BI0100001235 | 39.91 | CUM |
125 | 125 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | BI01010001010000000000000515BI0100001236 | 4.91 | CUM |
126 | 126 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. | BI01010001010000000000000515BI0100001237 | ||
127 | 127 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm | BI01010001010000000000000515BI0100001238 | ||
128 | 128 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. | BI01010001010000000000000515BI0100001239 | 89.781 | SQM |
129 | 129 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. | BI01010001010000000000000515BI0100001240 | 12.68 | CUM |
130 | 130 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. | BI01010001010000000000000515BI0100001241 | 6.75 | SQM |
131 | 131 | Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) | BI01010001010000000000000515BI0100001242 | ||
132 | 132 | Ground Floor | BI01010001010000000000000515BI0100001243 | 15.66 | CUM |
133 | 133 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in FOOTING excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001244 | 5.42 | CUM |
134 | 134 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in BEAM excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001245 | 5.98 | CUM |
135 | 135 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in COLUMN excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001246 | 2.93 | CUM |
136 | 136 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | BI01010001010000000000000515BI0100001247 | 17.07 | QTL. |
137 | 137 | 15 mm cement plaster on rough side of single or half brick wall of mix: (1 cement :4 coarse sand) | BI01010001010000000000000515BI0100001248 | 11.38 | SQM |
138 | 138 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand | BI01010001010000000000000515BI0100001249 | ||
139 | 139 | Ground Floor | BI01010001010000000000000515BI0100001250 | 85.64 | SQM |
140 | 140 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 fine sand. | BI01010001010000000000000515BI0100001251 | 148.26 | SQM |
141 | 141 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40mm thick floor). | BI01010001010000000000000515BI0100001252 | 71.47 | SQM |
142 | 142 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001253 | 582.87 | KG |
143 | 143 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). | BI01010001010000000000000515BI0100001254 | 148.26 | SQM |
144 | 144 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For ceiling) | BI01010001010000000000000515BI0100001255 | 85.64 | SQM |
145 | 145 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001256 | 166.72 | Sqm |
146 | 146 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001257 | 1057.9 | KG |
147 | 147 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8\nmm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel\nprimer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),\nexcluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001258 | 170.205 | SQM |
148 | 148 | electrical work | BI01010001010000000000000515BI0100001259 | ||
149 | 149 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. | BI01010001010000000000000515BI0100001260 | 12 | Each |
150 | 150 | Supply and wiring of submain with two number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 20 mm dia. heavy duty (2 mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. | BI01010001010000000000000515BI0100001261 | 25 | Metre |
151 | 151 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. | BI01010001010000000000000515BI0100001262 | ||
152 | 152 | 1 X 22 W CAT-AAA | BI01010001010000000000000515BI0100001263 | 12 | Each |
153 | 153 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve | BI01010001010000000000000515BI0100001264 | ||
154 | 154 | 6 - 32 amps.Cat. A | BI01010001010000000000000515BI0100001265 | 2 | Each |
155 | 155 | Supply and fixing of 6 Amp to 32 Amp DP MCB(10KA)C Curve | BI01010001010000000000000515BI0100001266 | ||
156 | 156 | 25 Amp. DP MCB(10KA) C Curve-Cat. A | BI01010001010000000000000515BI0100001267 | 1 | Each |
157 | 157 | Supply and fixing of flush/surface mounting distribution boards with additional metal door without MCB complete in all respects. | BI01010001010000000000000515BI0100001268 | ||
158 | 158 | 8 Way SPN Cat. B | BI01010001010000000000000515BI0100001269 | 1 | Each |
159 | 159 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. | BI01010001010000000000000515BI0100001270 | 8 | Each |
160 | 160 | Supply and fixing of single pole MCB blanking plate | BI01010001010000000000000515BI0100001271 | ||
161 | 161 | CAT A | BI01010001010000000000000515BI0100001272 | 4 | Each |
162 | 162 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. | BI01010001010000000000000515BI0100001273 | ||
163 | 163 | 6 sqmm 2 core | BI01010001010000000000000515BI0100001274 | 20 | Metre |
164 | 164 | TRAINING HALL STRENGTHENING | BI01010001010000000000000515BI0100001275 | ||
165 | 165 | Dismantling of Existing plaster including disposal of refuse as directed by the Engineer-in-charge with a distance of 60 metres (200 feet) | BI01010001010000000000000515BI0100001276 | 157.46 | CUM |
166 | 166 | Dismantling of Brick Coba work or stone work in lime or cement mortar including disposal of refuse as directed by the Engineer-in-charge with a distance of 60 metres (200 feet) | BI01010001010000000000000515BI0100001277 | 78.71 | CUM |
167 | 167 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound | BI01010001010000000000000515BI0100001278 | ||
168 | 168 | .conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above | BI01010001010000000000000515BI0100001279 | ||
169 | 169 | operations to be done in order and as directed and specified by the Engineerin- Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. | BI01010001010000000000000515BI0100001280 | 174.9 | SQM |
170 | 170 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand | BI01010001010000000000000515BI0100001281 | 157.46 | SQM |
171 | 171 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001282 | 92.34 | KG |
172 | 172 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For ceiling) | BI01010001010000000000000515BI0100001283 | 332.36 | SQM |
173 | 173 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. [STEEL SURFACE] | BI01010001010000000000000515BI0100001284 | 24.12 | Sqm |
174 | 174 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. [WOOD SURFACE] | BI01010001010000000000000515BI0100001285 | 6.12 | Sqm |
175 | 175 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. | BI01010001010000000000000515BI0100001286 | 174.9 | Sqm |
176 | 176 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes | BI01010001010000000000000515BI0100001287 | 19.08 | SQM |
177 | 177 | Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick | BI01010001010000000000000515BI0100001288 | 5.04 | SQM |
178 | 178 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. | BI01010001010000000000000515BI0100001289 | 2 | NOS. |
179 | 179 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a)300mm x 16mm . | BI01010001010000000000000515BI0100001290 | 2 | NOS |
180 | 180 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete | BI01010001010000000000000515BI0100001291 | ||
181 | 181 | (a) 250 mm x 10mm | BI01010001010000000000000515BI0100001292 | 4 | NOS |
182 | 182 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm | BI01010001010000000000000515BI0100001293 | 4 | NOS |
183 | 183 | Fixing of Door, windows/ventilators chaukhats in position. | BI01010001010000000000000515BI0100001294 | ||
184 | 184 | (a) Door chaukhats | BI01010001010000000000000515BI0100001295 | 5.04 | sqm |
185 | 185 | (b) Window chaukhats | BI01010001010000000000000515BI0100001296 | 2.25 | sqm |
186 | 186 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. | BI01010001010000000000000515BI0100001297 | ||
187 | 187 | a) 110mm diameter | BI01010001010000000000000515BI0100001298 | 20 | Metre |
188 | 188 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. | BI01010001010000000000000515BI0100001299 | ||
189 | 189 | a) 110mm | BI01010001010000000000000515BI0100001300 | 4 | Each |
190 | 190 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. | BI01010001010000000000000515BI0100001301 | ||
191 | 191 | a) 110mm | BI01010001010000000000000515BI0100001302 | 6 | Each |
192 | 192 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. | BI01010001010000000000000515BI0100001303 | 4 | Each |
193 | 193 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a | BI01010001010000000000000515BI0100001304 | ||
194 | 194 | Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001305 | 178.08 | sqm |
195 | 195 | electrical work | BI01010001010000000000000515BI0100001306 | ||
196 | 196 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash | BI01010001010000000000000515BI0100001307 | 12 | Each |
197 | 197 | Wiring point for fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash | BI01010001010000000000000515BI0100001308 | 8 | Each |
198 | 198 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & socket etc, complete in all respect including matching colour wash. | BI01010001010000000000000515BI0100001309 | 2 | Each |
199 | 199 | Supply & wiring of submains with two number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. | BI01010001010000000000000515BI0100001310 | 75 | Metre |
200 | 200 | Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. | BI01010001010000000000000515BI0100001311 | ||
201 | 201 | Cat. AAA | BI01010001010000000000000515BI0100001312 | 12 | Each |
202 | 202 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. | BI01010001010000000000000515BI0100001313 | ||
203 | 203 | BEE 5 Star rated-1200mm sweep | BI01010001010000000000000515BI0100001314 | 8 | Each |
204 | 204 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve | BI01010001010000000000000515BI0100001315 | ||
205 | 205 | 6 - 32 amps.Cat. A | BI01010001010000000000000515BI0100001316 | 5 | Each |
206 | 206 | Supply and fixing of 6 Amp to 32 Amp DP MCB(10KA)C Curve | BI01010001010000000000000515BI0100001317 | ||
207 | 207 | 32 Amp. DP MCB(10KA) C Curve-Cat. A | BI01010001010000000000000515BI0100001318 | 1 | Each |
208 | 208 | Supply and fixing of flush/surface mounting distribution boards with additional metal door without MCB complete in all respects. | BI01010001010000000000000515BI0100001319 | ||
209 | 209 | 12 Way SPN Cat. A | BI01010001010000000000000515BI0100001320 | 1 | Each |
210 | 210 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. | BI01010001010000000000000515BI0100001321 | 20 | Each |
211 | 211 | Supply and fixing of single pole MCB blanking plate | BI01010001010000000000000515BI0100001322 | ||
212 | 212 | CAT A | BI01010001010000000000000515BI0100001323 | 5 | Each |
213 | 213 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work. | BI01010001010000000000000515BI0100001324 | 3 | Each |
214 | 214 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. | BI01010001010000000000000515BI0100001325 | 8 | Each |
215 | 215 | Supply & fixing of cross clamp of required size fabricated from 50mm x 12mm M.S. flat complete with fan hook including painting etc. complete in all respects. | BI01010001010000000000000515BI0100001326 | 8 | Each |
216 | 216 | Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. | BI01010001010000000000000515BI0100001327 | 8 | Each |
217 | 217 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. | BI01010001010000000000000515BI0100001328 | ||
218 | 218 | 10 sqmm 2 core | BI01010001010000000000000515BI0100001329 | 15 | Metre |
219 | 219 | BOUNDARY WALL | BI01010001010000000000000515BI0100001330 | ||
220 | 220 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand)including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. | BI01010001010000000000000515BI0100001331 | 1019.25 | CUM |
221 | 221 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form-work,in foundation and floors. | BI01010001010000000000000515BI0100001332 | 118.62 | CUM |
222 | 222 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in BEAM and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-150. | BI01010001010000000000000515BI0100001333 | 83.473 | CUM |
223 | 223 | As in item 3 above but in R.C.C. columns in (Using 1:2:4 Mix concrete). | BI01010001010000000000000515BI0100001334 | 65.9 | CUM |
224 | 224 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in foundation | BI01010001010000000000000515BI0100001335 | 109.833 | CUM |
225 | 225 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work bending for proper shap as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured. | BI01010001010000000000000515BI0100001336 | 283.661 | QTL. |
226 | 226 | M-150 Brick work in Foundation in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls 115 mm thick. including supply of all material labour, Tools & Plants etc.required for proper completion of the work | BI01010001010000000000000515BI0100001337 | 241.633 | CUM |
227 | 227 | M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls 230 mm thick. including supply of all material labour, Tools & Plants etc.required for proper completion of the work | BI01010001010000000000000515BI0100001338 | 505.233 | CUM |
228 | 228 | 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1)1 cement:6 fine sand 1.25 F.M. | BI01010001010000000000000515BI0100001339 | 5838.74 | SQM |
229 | 229 | Finishing walls with water-proofing on cement paint of approved make such as super snowcem,durrocem,robiacem,guttucem supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white after thoroughly brushing the surface to powdered materials including curing and cost of all materials. | BI01010001010000000000000515BI0100001340 | 5838.74 | SQM |
230 | 230 | M.S. GATE | BI01010001010000000000000515BI0100001341 | ||
231 | 231 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand)including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. | BI01010001010000000000000515BI0100001342 | 8.26 | CUM |
232 | 232 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form-work,in foundation and floors. | BI01010001010000000000000515BI0100001343 | 0.46 | CUM |
233 | 233 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in BEAM and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-150. | BI01010001010000000000000515BI0100001344 | 2.67 | CUM |
234 | 234 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in SLAB excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001345 | 2.92 | CUM |
235 | 235 | As in item 4 above but in R.C.C. columns in (Using 1:2:4 Mix concrete). | BI01010001010000000000000515BI0100001346 | 1.75 | CUM |
236 | 236 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3 in foundation | BI01010001010000000000000515BI0100001347 | 1.56 | CUM |
237 | 237 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work bending for proper shap as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured. | BI01010001010000000000000515BI0100001348 | 9.749 | QTL. |
238 | 238 | M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls 115 mm thick. including supply of all material labour, Tools & Plants etc.required for proper completion of the work | BI01010001010000000000000515BI0100001349 | 3.41 | CUM |
239 | 239 | 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1)1 cement:6 fine sand 1.25 F.M. | BI01010001010000000000000515BI0100001350 | 55.68 | SQM |
240 | 240 | Finishing walls with water-proofing on cement paint of approved make such as super snowcem,durrocem,robiacem,guttucem supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white after thoroughly brushing the surface to powdered materials including curing and cost of all materials. | BI01010001010000000000000515BI0100001351 | 55.68 | SQM |
241 | 241 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001352 | 475.88 | KG |
242 | 242 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001353 | 10.58 | SQM |
243 | 243 | C.C. ROAD | BI01010001010000000000000515BI0100001354 | ||
244 | 244 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. | BI01010001010000000000000515BI0100001355 | 32.679 | CUM |
245 | 245 | Class M-150 brick work in 1:4 cement coarse sand (of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001356 | 30.064 | CUM |
246 | 246 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded brick aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors\nDwarf Wall | BI01010001010000000000000515BI0100001357 | 127.446 | CUM |
247 | 247 | C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in SLAB excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. | BI01010001010000000000000515BI0100001358 | 114.375 | CUM |
248 | 248 | Cost of Trimixing | BI01010001010000000000000515BI0100001359 | 762.5 | sqm. |
249 | 249 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. [DSR- 16.46.1*0.8222] | BI01010001010000000000000515BI0100001360 | 228.75 | RM |
250 | 250 | GST Extra as per applicable | BI01010001010000000000000515BI0100001361 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail