Supply Installation Testing Commissioning Of Fire Detection System . Construction . Of G Plus 1 Storied Gamma Knife Neurosurgery Building Within The Campus Of Ipgmer_Sskm Hospital Electrical Installation Work And Other Utility Services_Sitc Of Fire Det, Kolkata-West Bengal

Public Works Department-PWD has published Supply Installation Testing Commissioning Of Fire Detection System . Construction . Of G Plus 1 Storied Gamma Knife Neurosurgery Building Within The Campus Of Ipgmer_Sskm Hospital Electrical Installation Work And Other Utility Services_Sitc Of Fire Det. Submission Date for this Tender is 20-02-2021. Flame Detectors Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26818081
Supply Installation Testing Commissioning Of Fire Detection System . Construction . Of G Plus 1 Storied Gamma Knife Neurosurgery Building Within The Campus Of Ipgmer_Sskm Hospital Electrical Installation Work And Other Utility Services_Sitc Of Fire Det
Open Tender
Indian
West Bengal
Kolkata
20-02-2021

Tender Details

SUPPLY INSTALLATION TESTING COMMISSIONING Of Fire Detection System . ConstRUCTION . Of G Plus 1 Storied Gamma Knife Neurosurgery Building Within The Campus Of Ipgmer_Sskm Hospital Electrical Installation Work And Other Utility Services_Sitc Of Fire Detection System

Key Value

Document Fees
Refer document
EMD
INR 6078.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of (G+1) storied Gamma Knife Neurosurgery Building within the campus of IPGMER-SSKM Hospital, Electrical installation work and other utility services-SITC of Fire Detection System.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/GST ) Item1 34 Nos
2 2 Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor /Eaton/GST) Item2 3 Nos
3 3 Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/GST ) Item3 3 Nos
4 4 Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/GST ) Item4 3 Nos
5 5 Supply, Installation, Testing & Commissioning of Addressable transponder / Monitor Modules ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/GST) Item5 3 Nos
6 6 Supplying, installation, testing and commissioning of Addressable Relay Modules ( VDS / UL / FM / ULC approved ) for switching / integration of lift / AHU etc. complete as required. Item6 4 Nos
7 7 Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley /Eaton/GST ) Item7 20 Nos
8 8 Supply & Laying of 2 Core 1.5 sq. mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe(Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall. Item8 345 Mtrs
9 9 Supply, Installation, Testing & Commissioning of Power supply 230V AC to 24V DC with all other accessories (Make: Reputed) Item9 4 Nos
10 10 Supply, Installation, Testing & Commisioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL /ERTL / LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. Item10 1 No
11 11 The panel shall have in built rectifier, provision for external & internal printer (if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required. Item11
12 12 The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/GST ) Item12
13 13 NOTE : The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm & Signaling Code 5. Local Statutory Regulations. 6. Manufacturer Recommendation. 7. A single panel is to be installed for the whole installation. 8. The license software for programming FACP should be provided in separate storage media e.g. Pendrive, DVD etc along with source code. Item13
14 14 TESTS: 1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Item14
15 15 Terms and condition Item15
16 16 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Item16
17 17 Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.\n Item17
18 18 If any refurbished material is supplied and installed, penal action will be taken as per existing rules\n Item18
19 19 Defect liability period - 1 (One) year after completion of work Item19