Orissa Industrial Infrastructure Development Corporation-IDCO has published Construction Of Canteen Smart Class Room And Environmental Sustainability Plan At Gce Keonjhar. Submission Date for this Tender is 04-02-2021. Building Work Tenders in Keonjhar Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Jan-2021 | Corrigendum | Technical Bid | 04-02-2021 |
Name of Work:Construction of Canteen, Smart Class Rooms and Environmental Sustainability Plan at GCE, Keonjhar. (The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 2 | PART- I | |||
2 | 3 | Consrtruction of Canteen | |||
3 | 4 | CIVIL WORK | |||
4 | 5 | CIVIL & STRUCTURE | BI01010001010000000000000515BI0100001113 | ||
5 | 6 | a)Earth work in excavation in all kinds of soil (Ordinary, hard soil & stoney earth soil ) for foundation trenches within 50m. Initial lead and 1.5m initial lift including rough dressing and beaking clods to maximum 5 cm to 7 cm and laying in layers not exceeding 0.3 m in depth and as per specification approved by the department.= 256.45cum b) Covered drain= 85.73 Cum c)Plinth Protection= 34.29 Cum Total= 256.45cum+85.73cum + 34.29cum= 376.47cum) | BI01010001010000000000000515BI0100001114 | 376.47 | Cum |
6 | 7 | Extra lift of 1.5m or part there of over the initial lift of 1.5m in all kinds earth work ( 1st extra lift of 1.5mt (upto 3m) | BI01010001010000000000000515BI0100001115 | 46.6 | Cum |
7 | 8 | Cutting in disintegrated rock in foundation not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge | BI01010001010000000000000515BI0100001116 | 427.42 | Cum |
8 | 9 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001117 | 85.49 | Cum |
9 | 10 | Disposal of excess earth by mechanical means / manually including cost of loading, unloading, transporting & spreading to a level surface complete in all respects including cost of all labour, tools & plant etc. to complete the work | |||
10 | 11 | Upto 5 KM | BI01010001010000000000000515BI0100001118 | 341.93 | Cum |
11 | 12 | a)Supplying, filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalties of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only).= 744.07cum b) Covered drain= 17.15cum c) Plinth Protection= 12.86cum Total= 744.07cum+17.15cum+12.86cum=774.08cum) | |||
12 | 13 | GROUND FLOOR | BI01010001010000000000000515BI0100001119 | 774.08 | Cum |
13 | 14 | a)Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect.= 34.47cum b) Plinth Protection= 12.86cum Total= 34.47cum + 12.86cum = 47.33cum) | BI01010001010000000000000515BI0100001120 | 47.33 | Cum |
14 | 15 | a)Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect.= 145cum b) Covered drain= 17.15cum Total= 145cum + 17.15cum = 162.15cum) | BI01010001010000000000000515BI0100001121 | 162.15 | Cum |
15 | 16 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. | |||
16 | 17 | GROUND FLOOR | |||
17 | 18 | Foundation & bases of column | BI01010001010000000000000515BI0100001122 | 64.36 | Cum |
18 | 19 | Plinth Beam | BI01010001010000000000000515BI0100001123 | 49.53 | Cum |
19 | 20 | Pedestal & Columns | BI01010001010000000000000515BI0100001124 | 47.12 | Cum |
20 | 21 | Roof Beam | BI01010001010000000000000515BI0100001125 | 51.08 | Cum |
21 | 22 | Lintel | BI01010001010000000000000515BI0100001127 | 5.37 | Cum |
22 | 23 | Chajja | BI01010001010000000000000515BI0100001128 | 27.23 | Cum |
23 | 24 | a)R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas upt 4.3m height = 55.67cum b) Covered drain= 11.43cum Total= 55.67cum + 11.43cum = 67.10cum) | BI01010001010000000000000515BI0100001129 | 67.1 | Cum |
24 | 25 | Double stage centering and shuttering for roof slabs, Balconies and projections above 3.60m and upto 7.20m heights | |||
25 | 26 | GROUND FLOOR | BI01010001010000000000000515BI0100001130 | 54.18 | Sqm |
26 | 27 | a)Reinforcement for RCC work including straightening, cutting, bending, placing in position HYSD and binding all complete. lifting and placing in position as per design complete including cost of bars , binding wires , including cost of all materials, labour, conveyance, loading and unloading,, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights)-Thermo Mechanically Treated bars= 337.93Qntl b) Covered drain= 10.06 Qntl Total= 337.93 Qntl + 10.06 Qntl= 347.99 Qntl) | BI01010001010000000000000515BI0100001131 | ||
27 | 28 | GROUND FLOOR | BI01010001010000000000000515BI0100001132 | 347.99 | Qntl |
28 | 29 | a)Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge. (GF)=119.90cum b) Covered drain (G.F.)= 34.29cum c) Plinth Protection (GF)= 34.29cum Total= 119.90cum+34.29cum+34.29cum= 188.48cum) | BI01010001010000000000000515BI0100001134 | ||
29 | 30 | Foundation & Plinth | BI01010001010000000000000515BI0100001135 | 94.71 | Cum |
30 | 31 | Superstructure | |||
31 | 32 | GROUND FLOOR | BI01010001010000000000000515BI0100001136 | 188.48 | Cum |
32 | 33 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar(1:4) ( 1 cement: 4 sand) including watering and curing for the required period, imersing the bricks in vat before 6 hours of use, including cost of all material, labour, conveyance, loading and unloading, royalties, scaffolding, watering, curing, sundries, tools plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001137 | ||
33 | 34 | Superstructure | |||
34 | 35 | GROUND FLOOR | BI01010001010000000000000515BI0100001138 | 1.79 | Cum |
35 | 36 | Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Inside) | |||
36 | 37 | GROUND FLOOR | BI01010001010000000000000515BI0100001139 | 717.99 | Sqm |
37 | 38 | a)Providing 12 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Outside)= 858.72sqm b) Covered drain= 312.42Sqm c) Plinth protection= 171.45Sqm Total= 858.72sqm+312.42sqm+171.45sqm= 1342.59sqm) | |||
38 | 39 | GROUND FLOOR | BI01010001010000000000000515BI0100001140 | 1342.59 | Sqm |
39 | 40 | Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. | |||
40 | 41 | GROUND FLOOR | BI01010001010000000000000515BI0100001141 | 188.6 | Sqm |
41 | 42 | Fixing Kota tiles in floors treads or steps and landing on 25mm thick cement mortar (1:1) (1cement : 1 course and) and filling joints with of approved quality including cost, conveyance, taxes, cost of all labour etc. complete. | |||
42 | 43 | GROUND FLOOR | BI01010001010000000000000515BI0100001142 | 129.42 | Sqm |
43 | 44 | Providing Kota stone 16mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. | |||
44 | 45 | GROUND FLOOR | BI01010001010000000000000515BI0100001143 | 25.58 | Sqm |
45 | 46 | Providing vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm / 600mm x 300mm Colour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. | |||
46 | 47 | GROUND FLOOR | BI01010001010000000000000515BI0100001144 | 228.46 | Sqm |
47 | 48 | Providing vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm or 600mmx300mmColour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. | |||
48 | 49 | GROUND FLOOR | BI01010001010000000000000515BI0100001145 | 11.2 | Sqm |
49 | 50 | Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. | |||
50 | 51 | GROUND FLOOR | BI01010001010000000000000515BI0100001146 | 42.6 | Sqm |
51 | 52 | Providing Granite stone prepolished 10mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. | |||
52 | 53 | GROUND FLOOR | BI01010001010000000000000515BI0100001147 | 3.5 | Sqm |
53 | 54 | Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. | |||
54 | 55 | GROUND FLOOR | BI01010001010000000000000515BI0100001148 | 153.07 | Sqm |
55 | 56 | Providing & Fixing tiles 30cm x 30cm special plain / printed series ceramic floor tiles (Base price of the tile not less than Rs. 35 / sqft) having thickness 7mm to 8mm confirming to IS 13755 of approved make of Somany / Kajaria/ equivalent make in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing. work complete in all respect as per specification and direction of Engineer-in-charge.(in toilet floor area) | |||
56 | 57 | GROUND FLOOR | BI01010001010000000000000515BI0100001149 | 6.66 | Sqm |
57 | 58 | Providing & Fixing tiles of 30cm x 45 cm / 30 x 60cm / special plain/ printed series ceramic wall tiles of premium grade (Base price of the tile not less than Rs. 35 / sqft) having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make of Somany / Kajaria / Johnson or equivalent in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. (in toilet walls) | |||
58 | 59 | GROUND FLOOR | BI01010001010000000000000515BI0100001150 | 32.46 | Sqm |
59 | 60 | Providing and fixing factory made WPC (Wood Polymer Composite) door and window frames made of WPC extruded section of density 0.60 gmm/cc having size 127mmx63.25mm an overall dimension below (tolerance +/- 1mm), corners of door and window frames are to be jointed with stainless steel screws and fixed in position with hold fast lugs or dash fasteners of 8mm dia and 150mm length including cost of hold fast lugs/ fasteners cost, conveyance, labour charges etc as per the direction of Engineer-in-Charge. (Excluding GST). | |||
60 | 61 | GROUND FLOOR | BI01010001010000000000000515BI0100001151 | 140.11 | RMT |
61 | 62 | Providing and fixing of 32mm thick WPC Door Shutter(Solid) with minimum density of 0.6 gm/cc with teak edge leaping to the periphery of the shutter with pilishing as per detailed drawing with including, all hardwares & fixtures, SS tower bolt(150mm),Door stopper,SS aldrop(250mm),SS handle(200mm length),ss handle (150mm length) & SS Butt hinges -125mm x 65mm x2.12mm .including cost, conveyance, loading, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge | BI01010001010000000000000515BI0100001152 | ||
62 | 63 | GROUND FLOOR | BI01010001010000000000000515BI0100001153 | 68.14 | Sqm |
63 | 64 | Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) | |||
64 | 65 | GROUND FLOOR | BI01010001010000000000000515BI0100001154 | 41.8 | Kg |
65 | 66 | Finishing wall surface of walls with wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T&P etc. complete the work as per the direction of engineer incharge. | |||
66 | 67 | GROUND FLOOR | BI01010001010000000000000515BI0100001155 | 906.59 | Sqm |
67 | 68 | Providing Wall painting with Oil bound distemper paint two and more coats to get an even shade including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge. | |||
68 | 69 | GROUND FLOOR | BI01010001010000000000000515BI0100001156 | 906.59 | Sqm |
69 | 70 | Providing Wall painting with cement primer(oil bound )one coat to the internal wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge. | |||
70 | 71 | GROUND FLOOR | BI01010001010000000000000515BI0100001157 | 906.59 | Sqm |
71 | 72 | Painting to external surface of building with two coats of weather seal coat of approved shade and quality of approved design after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. | |||
72 | 73 | GROUND FLOOR | 429.36 | Sqm | |
73 | 74 | Providing Wall painting with cement primer(water bound) one coat to the external wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects. | |||
74 | 75 | GROUND FLOOR | 429.36 | Sqm | |
75 | 76 | Providing and painting two coats with synthetic enamel paint of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. | |||
76 | 77 | GROUND FLOOR | 91.87 | Sqm | |
77 | 78 | Providing approved primer of one coat to the Iron work including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects. | |||
78 | 79 | GROUND FLOOR | 91.87 | Sqm | |
79 | 80 | Supplying , fitting and Fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel square pipe bracing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification , buffing, polishing etc. with cost, conveyance, ,es of all materials, labour, T&P, etc. required for the complete in all respects. | |||
80 | 81 | GROUND FLOOR | 7.32 | RMT | |
81 | 82 | Waterproofing to the roof slab\n(a) Surface preparation : \nCleaning the surface thoroughly by chipping the roof slabs using breakers, wire brush, mechanical grinder for making it free from all loose particles, dust etc. then total cleaning through air blower followed by water jetting and allowing the surface to dry.\n(b) Application :\nSupply and application of Nano Technology OrganoSilane based Zycosil + @ 1:20 (one part Zycosil + and 20 parts of clean water) to the saturation level on the entire flat surface and upto 300mm (1ft.) to the parapet walls and then allowing for drying 24 hrs., test the surface for hydrophobicity. Then application of 100% acrylic co-polymer Zycoprime+, cement and fine sand (100 mesh) mixed at a consistency of paste form and filling drainage pipes gaps. Then application of one coat of Zycoat mix of Zycoprime + and grey cement @ 1:1.5 ratio ( 1 part Zycoprime + and 1.5 part cement). 2ndcpat of Zycoat mix to be applied after the drying of first coat in the same procedure followed by sprinkling of sieved sand on the top of the slurry. Then allow it to dry followed by proper curing with water for at least two days.\n(c) Coving :\nCoving has to be done with Zycomix (a mortar prepared with Zycoprime+, cement and sand in the ratio of 1:5:15 and water as per workability to obtain a uniform paste). Finally cure with water to the entire treated roof and parapet wall for three days. | 548.54 | Sqm | |
82 | 83 | Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of 6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, ,es of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. | |||
83 | 84 | FIRST FLOOR AND HEADROOM | 548.54 | Sqm | |
84 | 85 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment) | 901.89 | Sqm | |
85 | 86 | Supply and installing uPVC- Sliding windows/ doors made out of lead free green profiles of ENCRAFT/ FINESTA/ KOMMERLING/ Equivalent make with a GREENLINE mark having two tracks and two sashes (Shutters) with frame dimension of 58mmx49mm and sash dimension of 61mmx47mmx37mm for windows and sash dimension of 75mmx61mmx37mm or 85mmx71mmx37mm for doors with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm to 2mm. The sash will be fitted with 5/6mm clear glass (float/toughened). The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extursion facility in India and the windows to be assembled and installed by an authorised fabrication partner. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside/ Outside of Dowcorning/ GE or quivalent. | |||
86 | 87 | GROUND FLOOR | 91.87 | Sqm | |
87 | 88 | Supplying & Fixing of Mild steel tubular Pipe made out of ERW tubes, grade YST 210 conforming to ISS NO. 1161/79 ( 3rd revision) duly painted with red oxide primer as per the architectural requirement for application . positioning with necessary accessories with scaffolding complete in all respects as per direction of Engineer-in-charge. . | 2168.67 | Kg | |
88 | 89 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdor floors such as footpath, courtyard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge | 1.22 | Sqm | |
89 | 90 | Supplying and laying of hydraulically pressed and mechanically compacted pre cast interlocking COBBLE STONE pavers of M-30 grade ,60MM thick (200x200)mm size of required colour and coral shaped over 50mm thick compacted bed of sand,compacting and proper laying of paver blocks in to the sand bedding layer through vibrator compaction by using plate vibrator,filling the joints with sand and finishing the surface including cutting of blocks at the edges with all labour and materials cost etc.work complete as per direction of Engineer-in-charge. | 146.53 | Sqm | |
90 | 91 | COVERED DRAIN | |||
91 | 92 | Providing neat cement punning over plastered/ concrete surface including watering and curing complete with cost, coveyance, loading and unloading, royalties of all materials and cost of all labour, T&P and scaffolding required for the work etc. as directed by the Engineer in charge. | 312.42 | Sqm | |
92 | 93 | PLINTH PROTECTION | |||
93 | 94 | Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour, cess and T&P etc. required for the work complete. | 8.58 | Sqm | |
94 | 95 | PH WORK | |||
95 | 96 | Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) with CISTERN etc all complete as per specification and direction of the Engineer in charge.JAQUAR ESSCO MAKE CAT- ECS-WHT-551PNPP183LZ | 2 | EACH | |
96 | 97 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge | 2 | EACH | |
97 | 98 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge | |||
98 | 99 | 550x400mm Wash hand basin with Porcelain pedestal(Parryware/Hindwar/Somany/Orient bell) | 10 | EACH | |
99 | 100 | Providing, Supplying & Fixing of Single Towel Rail, Stainless Steel of Jaquar (Cat No.- ACN- CHR-1111SM) Size- 600 mm long with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 4 | EACH | |
100 | 101 | Providing, Supplying & Fixing of Towel Ring Square of Jaquar (Cat No. - ACN- CHR-1121N) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 10 | EACH | |
101 | 102 | Providing, Supplying & Fixing of SOAP DISH of Jaquar (Cat No. - ACN-CHR-1131N) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 14 | EACH | |
102 | 103 | Providing, Supplying & Fixing of Hand Shower (Health Faucet) with 8mm dia, 1.2m long flexible tube and wall hook of Jaquar (Cat No.- ALD-CHR-573)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 2 | EACH | |
103 | 104 | Providing, Supplying & Fixing of 2 way Bib cock with wall flange of Jaquar (15mm dia cp two way bib cock(Jaquar )CON-CHR-041KN) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 2 | EACH | |
104 | 105 | Fixing of Bib cock (with straight line model) with wall flange polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. (15 mm dia CP Bib cock (Jaquar)CON-CHR-037KN.) | 10 | EACH | |
105 | 106 | Providing, Supplying & Fixing of Angular stop cock with Wall Flange of Jaquar (15mm dia CP angle stop cock(Jaquar)CON-CHR-059KN)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 25 | EACH | |
106 | 107 | Providing, Supplying & Fixing of Shower Arm 20mm Dia & 450mm Long Round Shape with 90º Bend for wall Mounted Showers with Flange with Maze Overhead Shower 240mm Round Shape single flow (Body & Face Plate Stainless Steel with chrome finish) with rubit cleaning system of Jaquar (Cat No.- SHA-CHR-479L450 and OHS-CHR-1623)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 2 | EACH | |
107 | 108 | Providing, Supplying & Fixing of Double hook of Jaquar (Cat No.- ANC-CHR-1161N)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | 2 | EACH | |
108 | 109 | Providing, Supplying & Fixing of all materials, labour, T&P and fixing mirror of 600 x 450mm size (Atul/ Twin bird/Charlie/ eqv )glass mounted on 4mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge.as per PHD S/R Rate | 10 | EACH | |
109 | 110 | Providing & Fixing of with 125mm stainless steel grating with/ without hole for waste pipe in floors / at any location cost includes all materials, labour, tools,plant etc. complete in all respects. | 22 | EACH | |
110 | 111 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes (type-A / ring fit type ) with all PVC fittings of ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and laying in trenches including all pipe fittings, jointing materials, tools plant, labour & all material, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. | |||
111 | 112 | 160mm dia PVC (SWR) pipe class "A" ( with wall thickness of 3.2mm to 3.8mm) | 50 | MTR | |
112 | 113 | 110 mm dia PVC (SWR) pipe Class ‘A’ (with wall thick of 2.20 mm to 2.70 mm) | 25 | MTR | |
113 | 114 | 75 mm dia PVC (SWR) pipe Class ‘A’ (with wall thick of 1.8 mm to 2.20 mm ) | 25 | MTR | |
114 | 115 | Providing all materials, labour and T&P for fixing of Upvc SWR fittings | |||
115 | 116 | 110mm coupler | 10 | No. | |
116 | 117 | 110mm x 75mm reducer | 10 | No. | |
117 | 118 | Fixing ferrule confirming to IS:2692-1978 OF 25mm dia | 8 | No. | |
118 | 119 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for 160mm pvc pipes of the following internal diameter including curing complete as per specification | 50 | MTR | |
119 | 120 | Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size flyash Brick having crushing strength not less than 75kg/ sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of PVC Gully Trap and pre-cast factory made (SFRC) cover with frame of opening size 260mmx260mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size, earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50mt lead as per specification, design & drawing including cost of curing and all royalty, cost, conveyance etc. but Excluding GST all complete as per specification & direction of EIC.\nInner size 300mmx300mmx450mm depth Gully Trap chamber | 15 | each | |
120 | 121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. | |||
121 | 122 | GROUND FLOOR | |||
122 | 123 | 15 mm nominal outer dia Pipes | 30 | MTR | |
123 | 124 | 20 mm nominal outer dia Pipes | 30 | MTR | |
124 | 125 | 25 mm nominal outer dia Pipes | 15 | MTR | |
125 | 126 | 32 mm nominal outer dia Pipes | 15 | MTR | |
126 | 127 | 40 mm nominal outer dia Pipes | 40 | MTR | |
127 | 128 | 50 mm nominal outer dia Pipes | 60 | MTR | |
128 | 129 | Cutting grooves in pucca floors and walls for taking GI/PVC /CPVC pipes including making good the damages caused with cost of all material,labour, scafolding, tools, plant, royalty etc. complete in all respects. | 35 | MTR | |
129 | 130 | Providing all materials required for construction of manhole chamber with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 200mm thick, 12mm thick cement plaster 1:3 both in outer & inner surface of the wall & bottom, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed. RCC M-25 with 20mm & down size H.G crusher broken chips having minimum cube strength 200Kg/Sqcm at 28 days confirming to IS-453/76 & IS-3370 for roof slab of 150mm average thick with form work as per the requied size including cost for MS reinforcement as per approved design & drawing & fixing of Pre-cast factory made manhole cover with frame ( medium duty) for opening of 560mm including cost of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge. | |||
130 | 131 | Manhole chamber of Inner size 900mmx800mmx 450mm depth. | 3 | EACH | |
131 | 132 | Providing and placing on terrace (at all floor levels) 2000 litre polythelene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlets outlet and overflow pipe along with roof top pedestral including all fittings complete in all respects.make-sintex | 2 | EACH | |
132 | 133 | Providing and fixing 25mm dia CPVC ball valve of approved make and quality with all materials, labour, tools, plant, scafolding , making good the damages caused, complete in all respects | 5 | EACH | |
133 | 134 | Providing and fixing 40mm dia CPVC BALL valve of approved make and quality with all materials, labour, tools, plant, scafolding , making good the damages caused, complete in all respects | 5 | EACH | |
134 | 135 | Supplying all materials,labours,T&P and cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI /CPVC /PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. | 20 | EACH | |
135 | 136 | ELECTRICAL WORK | |||
136 | 137 | Internal Wiring Items | |||
137 | 138 | wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC rigid conduit with 6Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size, MS box with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. | |||
138 | 139 | Single light controlled by one 6A switch or first point GROUP-A | 5 | Nos | |
139 | 140 | Single light controlled by one 6A switch or first point GROUP-B | 10 | Nos | |
140 | 141 | Single light controlled by one 6A switch or first point GROUP-C | 41 | Nos | |
141 | 142 | subsequent point of group controlWiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. | 22 | Nos | |
142 | 143 | 6A Plug on the same board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved | 10 | Nos | |
143 | 144 | 2x6A Plug on the separate board For computer/UPS/other power point or TV point & other use for Data center/go down area with complete fitting by 02 nos of 6A switch & socket(modular type) cover,modular board & other required accessories of ISI marked as approved | 5 | Nos | |
144 | 145 | Supplying and fixing 15/16A modular socket with 15/16A Switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | 8 | Nos | |
145 | 146 | Wiring for circuits and submain with following number & sizes of FRLSH PVC insulated 1100 volt grade multistranded copper conductor wire run inside nonmetallic PVC rigid conduit recessed in ceiling/ column/ walls of building including supply of all materials such as wires, conduit, junction box & pull box / duly clamped to wall /ceiling or cable tray as suitable etc complete with making good the damages caused as required and as per direction of Engineer-in-charge. | |||
146 | 147 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. | 200 | Mtr | |
147 | 148 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor. | 150 | Mtr | |
148 | 149 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor. | 100 | Mtr | |
149 | 150 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 6 sq. mm copper wire for earth continuty conductor. | 150 | Mtr | |
150 | 151 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor. | 70 | Mtr | |
151 | 152 | Supply, delivery, installation & testing of AC boards consisting of 1 No 20-A DP Modular switch with indicator and 1 No 16A Moular socket in indivisual Modular G.I Box making good the damages caused complete as required and as per direction of Engineer-in-charge. | 10 | Mtr | |
152 | 153 | Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle telephone socket outlet. | 2 | Mtr | |
153 | 154 | Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle tv socket outlet. | 4 | Mtr | |
154 | 155 | Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Four Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. | 80 | Mtr | |
155 | 156 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. | 100 | Mtr | |
156 | 157 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||
157 | 158 | 20 MM | 10 | Mtr | |
158 | 159 | 25 MM | 12 | Mtr | |
159 | 160 | Light fitting & fixtures | |||
160 | 161 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (Havells make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection. | 5 | Nos | |
161 | 162 | Supply delivery, installation, testing & commissioning of 450 mm (18") size Heavy Duty Exhaust Fan, 1400 RPM similar to Havells or equivalent complete etc.as required..(For both in and out air exhaust system) | 2 | Nos | |
162 | 163 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of Havells Pacer Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) | 35 | Nos | |
163 | 164 | Supply of Surface mounted indoor type 40 WATT LED TUBE with High quality aluminium Extruded with decorative caps housing , 6500 CCT diffuser and Lamp Similar to Jaquar Cat No. LGLZ01X40xC | 35 | Nos | |
164 | 165 | Supply delivery, installation, testing & commissioning of following types 45 W LED premises LIGHT 6000 CCT fixtures similar to Jaquar cat no-.LSRT01S045XC | 8 | Nos | |
165 | 166 | Supply delivery, installation, testing & commissioning of following types16 WATT LED BOLLARD LIGHT Frosted pc diffuser inbuilt LED Simillar to JAQUAR :LBLD03R108XW | 10 | Nos | |
166 | 167 | Supply delivery, installation, testing & commissioning of following types 9 WATT LED BULB | 4 | Nos | |
167 | 168 | Supply delivery, installation, testing & commissioning of 2X 3 WATT Die cast aluminium housing ,tempered glass diffuser IP54 (UP-DOWN ) LEEDZ LIGHT Jaquar Make: LWWL01S203XW | 4 | Nos | |
168 | 169 | Branch Distribution Boards | |||
169 | 170 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar make, or any other equivalent A catagories reputed make ISI marked as approved | |||
170 | 171 | 12 way, Double Door SPN DB (FOR LIGHT ) | 2 | Nos | |
171 | 172 | 4 way, Double Door TPN DB (FOR POWER) | 2 | Nos | |
172 | 173 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of any other reputed make ISI marked as approved in the existing MCB DB complete with connections. | 40 | Nos | |
173 | 174 | Supply and fixing 25 Amps DP 240 volts, RCCB,30mA any other reputed make ISI marked as approved in the existing MCB DB complete with connections. | 2 | Nos | |
174 | 175 | Supply and fixing 40 4P Amps MCI 415 volts,any other reputed make ISI marked as approved in the existing MCB DB complete with connections. | 2 | Nos | |
175 | 176 | Earthing | |||
176 | 177 | Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 4.5 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. | 2 | Nos | |
177 | 178 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. | 20 | Mtr | |
178 | 179 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. | 20 | Mtr | |
179 | 180 | Distribution Boards | |||
180 | 181 | Supply, delivery, installation, testing & commissioning of L.T. indoor floor /wall mounted type distribution boards made out of 2mm thick CR sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged door and compartmental arrangement for each equipment & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. | |||
181 | 182 | MDB-FLOOR DB | |||
182 | 183 | Incomer:2 nos. 63-80A 4P MCCB(36 KA) with adjustable thermal setting+NL | |||
183 | 184 | Bus bar: 4 nos. 100A Busbar duly sleeved | |||
184 | 185 | 1 no. 63A 4P onload change over switch | |||
185 | 186 | 3 Nos 40A 4P MCB.'C' (10kA) | |||
186 | 187 | 4 No 32A DP MCB.'C' (10kA) | |||
187 | 188 | 6 Nos 6-32A SP MCB.'C' (10kA) | |||
188 | 189 | Instruments: 2 set.LED type phase indicating lamps with control fuses | |||
189 | 190 | 1nos.VAF + PF Digital Meter | |||
190 | 191 | Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. | 1 | Set | |
191 | 192 | Cable | |||
192 | 193 | Supplying, laying & testing of following size of PVC insulated XLPE shethed / strip armoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. | |||
193 | 194 | 3.5 core x 35 sq mm Aluminium armoured Cable. | 60 | Mtr | |
194 | 195 | 3 core x 2.5 sq mm copper armoured Cable. | 100 | Mtr | |
195 | 196 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable. | |||
196 | 197 | 3.5 core x 35 sq mm Aluminium armoured Cable. | 2 | Nos | |
197 | 198 | PART-II | |||
198 | 199 | Construction of SMART CLASS ROOMS | |||
199 | 200 | Civil portion of work | |||
200 | 201 | INTERIOR WORK. | |||
201 | 202 | Providing suspended of gypsum false ceiling approved make which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20 mm and another flange of 30 mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylo sleeves and screws at 610mm centres. Then suspending G.I intermidiate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at 1220 mm centre with ceiling angle of with 25mm X 10mm X 0.55mm thick to soffit with G.I cleat and steel expantion fastness. Ceiling section of 0.55mm thickness having knuled web of 51.5mm and two flanges of 26mm each with lips of 105mm are then fixed to the intermidiate channel with the help of connectiong clip and in direction perpendicular to the intermidiate channel at 457mm centres. 12.5mm tappered edge Gyp. Board (Conformining to IS 2095-1982) is then screw fixed to ceiling section with 25mm drywall screwsat 230mm centres. Screw fixing is done mechanically either with screw driver drilling machine with suitable attachment etc. complete in all respect exculding GST as directed by Engineer-in-charge. | 422.8 | Sqm | |
202 | 203 | Providing and Fixing of Armstrong/Gyprex / Eqv suspended ceiling system with Fine fissured microlook tiles in modules size of 600 x 600 x 15mm laid on armstrong silhouette reveal profile grid system with 15mm white flange incorporating a 3 mm or 6mm central recesss.Silhouette mail runner & cross tee ti have mitred ends and birdsmuth notches to provide mitered cruciform junction. | 85.82 | Cum | |
203 | 204 | Finishing surface of walls with cement based wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour, T&P etc. complete. | |||
204 | 205 | GROUND FLOOR | 908.32 | Sqm | |
205 | 206 | FIRST FLOOR | 681.24 | Sqm | |
206 | 207 | Providing Wall painting with cement primer(oil bound )one coat to the internal wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge. | |||
207 | 208 | GROUND FLOOR | 857.56 | Sqm | |
208 | 209 | FIRST FLOOR | 500.07 | Sqm | |
209 | 210 | Providing Wall painting with Oil bound distemper paint two and more coats to get an even shade including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge. | |||
210 | 211 | GROUND FLOOR | 857.56 | Sqm | |
211 | 212 | FIRST FLOOR | 500.07 | Sqm | |
212 | 213 | Providing & applying two or more coats of Best quality Acrylic Emulsion Paint of approved brand, shade and manufacture to give an even shade on walls and ceiling, including providing necessary scaffolding, cleaning the surface with water to remove all coating dust etc. including cost of all materials, labour, T&P, , taxes etc. complete as per specification. complete in all respect. | 422.8 | Sqm | |
213 | 214 | Providing & fixing wall & column panelling by fixing 19mm BWR grade ply confirming to IS-303 fixed with wall by secondary hard wood ( 50x50mm ) forming a grid of 600 x 600mm & screws . Then fixing laminate 1.00mm thick of approved make & shade as per detailed working drawing cost includes all material, labour, tax, lead, T&P etc. complete in all respects as per the direction of Architect/Engineer in charge.\n(Ply /Block board Make -Greenmax panel /Century/green)\n(Laminate Make -Royal touch / Green /marino) | 193.34 | Sqm | |
214 | 215 | Providing anf fixing POP cornice of 100mm wide of approved design, including necessary fixing, jointing anf finishing without any crack including cost of labour, cost of materials with staging/ scaffolding etc complete in all respect (without GST) as per specification and as per direction of Engineer-in-charge. | 347.76 | RMT | |
215 | 216 | Providing and fixing factory made WPC (Wood Polymer Composite) door and window frames made of WPC extruded section of density 0.60 gmm/cc having size 127mmx63.25mm an overall dimension below (tolerance +/- 1mm), corners of door and window frames are to be jointed with stainless steel screws and fixed in position with hold fast lugs or dash fasteners of 8mm dia and 150mm length including cost of hold fast lugs/ fasteners cost, conveyance, labour charges etc as per the direction of Engineer-in-Charge. (Excluding GST). | 6.1 | RMT | |
216 | 217 | Providing and fixing of 32mm thick WPC Door Shutter(Solid) with minimum density 0.6gm/cc with teak edge leaping to the periphery of the shutter with pilishing as per detailed drawing with including, all hardwares & fixtures, SS tower bolt(150mm),Door stopper,SS aldrop(250mm),SS handle(200mm length),ss handle (150mm length) & SS Butt hinges -125mm x 65mm x2.12mm .including cost, conveyance, loading, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge | |||
217 | 218 | GROUND FLOOR and FIRST FLOOR | 7.8 | Sqm | |
218 | 219 | Supply and installing uPVC- Sliding windows/ doors made out of lead free green profiles of ENCRAFT/ FINESTA/ KOMMERLING/ Equivalent make with a GREENLINE mark having two tracks and two sashes (Shutters) with frame dimension of 58mmx49mm and sash dimension of 61mmx47mmx37mm for windows and sash dimension of 75mmx61mmx37mm or 85mmx71mmx37mm for doors with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm to 2mm. The sash will be fitted with 5/6mm clear glass (float/toughened). The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extursion facility in India and the windows to be assembled and installed by an authorised fabrication partner. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside/ Outside of Dowcorning/ GE or quivalent. | |||
219 | 220 | GROUND FLOOR | 2.23 | Sqm | |
220 | 221 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. | |||
221 | 222 | GROUND FLOOR- Lintel | 0.69 | Cum | |
222 | 223 | Reinforcement for RCC work including straightening, cutting, bending, placing in position HYSD and binding all complete. lifting and placing in position as per design complete including cost of bars , binding wires , including cost of all materials, labour, conveyance, loading and unloading,, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights)-Thermo Mechanically Treated bars | |||
223 | 224 | GROUND FLOOR | 0.73 | Qntl | |
224 | 225 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge. | |||
225 | 226 | GROUND FLOOR | 8.83 | Cum | |
226 | 227 | Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Inside) | |||
227 | 228 | GROUND FLOOR | 75.34 | Sqm | |
228 | 229 | DISMENTAL WORK | |||
229 | 230 | Dismantling brick or stone masonry in lime or cement mortar above 3m. Height including stacking the useful materials for reuse and removing the debris within 50m. Lead | |||
230 | 231 | GROUND FLOOR | 11.37 | Cum | |
231 | 232 | Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead | |||
232 | 233 | GROUND FLOOR | 95.4 | Sqm | |
233 | 234 | Dismantling and removing R.C.C columns, beams, slab, staircase, landing, lintels including stacking the useful materials for reuse and removing the debris within 50m lead | |||
234 | 235 | GROUND FLOOR | 0.69 | Cum | |
235 | 236 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead | |||
236 | 237 | GROUND FLOOR | 10.03 | Sqm | |
237 | 238 | Furnitures | |||
238 | 239 | Providing and fixing Student Desk (Five Seater) - Made out of Angle iron frame 40 x 40 x 3/2.5mm. Min. thick, duly tig welded. The Metal body is to be powder coated with a thickness of 40 Micron, The Top should be of 25 mm PLPB confirming to IS 12823 - 1990, Table Dimension - 3750 X 550 X 750 mm ht ( Five Seater). The Modesty of the Table will be of 17/18 mm PLPB, the top and modesty should be Steam resistance, Crack resistance, Stain resistance, The top loading Capacity will be of 150 - 175 kgs, there should be levellers for adjustment below the legs, The manufacturer should have the following Certificates ISO 9001: 2015, 14001:2004, 45001:2018 & BIFMA E3 with Green Guard (make-Decor-X) complete in all respect as per specification and direction of Architect-in-charge and Engineer-in-charge | 91 | Each | |
239 | 240 | Visitor Chair-Cantiliver Chair Size (Back-H-470xW-460,Seat-D-460x470)mm & Min. Height-430mm. Multipurpose fixed cantiliver chair & armrest with pading & metal base. A 14 mm thick, BWR grade plywood (IS:303) is used to make the seat and back. Deep cushioned back and seat confirm to body contours for proper aligment, posture and all day comfort. . Color-Black. | 455 | Each | |
240 | 241 | INTERNAL ELECTRICAL WORK | |||
241 | 242 | a)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 42 | Nos | |
242 | 243 | b) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. | 49 | Nos | |
243 | 244 | c)Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 7 | Nos | |
244 | 245 | d)Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 7 | Nos | |
245 | 246 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. | |||
246 | 247 | 1/2 Module (75mmX75mm)(separate board ,telephone,tv) | 14 | Nos | |
247 | 248 | 4 Module (125mmX75mm) | 7 | Nos | |
248 | 249 | 6 Module (200mmX75mm) (for computer only) | 14 | Nos | |
249 | 250 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Make-Anchor/Panasonic/Legrand/Siemens/INDOASIAN) | |||
250 | 251 | 5/6 amps switch (for computer) | 28 | Nos | |
251 | 252 | 3 pin 5/6 amp socket outlet(for computer) | 28 | Nos | |
252 | 253 | telephone socket outlet | 7 | Nos | |
253 | 254 | television socket outlet | 7 | Nos | |
254 | 255 | .Supply of all required materials and fixing of 15-20 Amp DOL starter mounted on modular box with 15Amp socket for A/C complete with all respect as per the instruction of Engineer-in-Charge/Bank (Make-Anchor/Panasonic/Legrand/Siemens/L&T) | 42 | Nos | |
255 | 256 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 10 | Nos | |
256 | 257 | Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Twin Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. | 140 | Mtr | |
257 | 258 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. | 140 | Mtr | |
258 | 259 | Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid PVC Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on surface along with other accessories and 18 SWG GI Fish Wire complete for Telephone / TV / Computer / Circuit or Sub main wiring as required & as per Direction of Engineer-In-Charge. | |||
259 | 260 | 20 mm dia. | 40 | Mtr | |
260 | 261 | 25 mm dia. | 50 | Mtr | |
261 | 262 | Wiring for Circuits and Submain with following number & sizes of PVC insulated 1100 Volt Grade Multistranded Copper Conductor FRLS Wire run inside 2 mm thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc. complete with making good the damages caused as required and as per Direction of Engineer-In-Charge. Make.Havells/Anchor/Panasonic/KBL | |||
262 | 263 | 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD | 350 | Mtr | |
263 | 264 | 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 4 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD. | 250 | Mtr | |
264 | 265 | 2 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 6 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD. | 200 | Mtr | |
265 | 266 | UPS BACK UP POWER SUPPLY | |||
266 | 267 | Supply, instllation, testing and commissioning of 5KVA Online UPS with unity out put per factor 95% overal effecency suitable to work 0-50digree centegrate ambient temprature including SMF back of 60minutes, complete with all other accessories as required & as per Direction of Engineer-In-Charge . MAKE: Emerson/APC/Numeric | 2 | Nos | |
267 | 268 | DISTRUBUTION BOARD | |||
268 | 269 | Supplying and fixing following way, single pole and neutral,\nsheet steel, MCB distribution board, 240 V, on surface/ recess,\ncomplete with tinned copper bus bar, neutral bus bar, earth\nbar, din bar, interconnections, powder painted including\nearthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door | 2 | Nos | |
269 | 270 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
270 | 271 | Single pole | 20 | Nos | |
271 | 272 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 5 | Nos | |
272 | 273 | Supplying and fixing following rating, double pole, (single phase\nand neutral), 240 V, residual current circuit breaker (RCCB),\nhaving a sensitivity current 300 mA in the existing MCB DB\ncomplete with connections, testing and commissioning etc. as\nrequired. | |||
273 | 274 | 40 amp 2pole RCCB | 2 | Nos | |
274 | 275 | UPS PANEL | |||
275 | 276 | UPS PANEL with 63 A DP MCB (10KA) as Incomer , Outgoings- 32 A 2 P MCB (10KA)-3 Nos with E.C Bus Bars. | 1 | set | |
276 | 277 | FITTINGS & FIXTURES: | |||
277 | 278 | Supply,Installation and testing of following types of LED Tube Fixtures Directly on Wall / Ceiling/ Structure of Building with all accessories such as Electronics Ballast, Lamps, Stove Enameled Box, Perplex Sheet Cover etc. complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge. Make- JAQUAR,Philips,panasonic,HALONIX | |||
278 | 279 | Supply of Recess mounted 42 watt indoor type Square LED 2'' x2'' Luminaire with LED Lamp Similar to HALONIX Cat No. HLFPR22-05-42-CW-R | 28 | Nos | |
279 | 280 | Supply of Recess mounted 24 watt indoor type LED Backlite round down lighter made of spun with high efficent LED & Glare free opal diffuser IP20 Similar to HALONIX Cat No. HLDLR -R27S-24-CW-R | 63 | Nos | |
280 | 281 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 91 | Nos | |
281 | 282 | SMART CLASSROOM | |||
282 | 283 | SITC OF IFPD- 75 Inches: Resolution 4 K (3840x2160) Brightness 500 nits MAKE & MODEL: Globus IFPD-E75 | 7 | Nos | |
283 | 284 | SITC OF Electronic Lectern/Digital Podium: Display Size: 19 Inch., Type of Display: Interactive panel, Resolution: 1920 x 1080 Full HD with Intel Core i3, 4 GB RAM, 1 TB HDD & Windows 10 SL , Manual Tilt, No RFID, 100 W Amplifier with 2X50 watt speakers, controller, Gooseneck microphone, colar microphone, wireless handle microphone for students and required acessories etc. \nMAKE & MODEL:Globus GEL-22N | 7 | Nos | |
284 | 285 | SITC OF Visual Presenter: Resolution: SXGA,Video Frame Rate (fps):30 MAKE & MODEL:Globus GVP-301 | 7 | Nos | |
285 | 286 | SITC OF 2MP IR Dome Camera (2.8mm Lens) 1/2.8” SONY - CMOS (Exmor Technology - STARVIS Series), 2MP, 0Lux with IR LED ON Horizontal Field of View: 113 degrees, IR Range of up to 30 meters, Video Analytics: Trip Wire, Intrusion Detection and Motion Detection, H.265/H.264/MJPEG Video Compression, PoE Support, NAS Storage, SD Card(512GB), Quad Stream Support, True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB, IK10, IP66, BIS, CE, FCC and RoHS MAKE & MODEL:Matrix- MIDR20FL28CWS | 14 | Nos | |
286 | 287 | SITC OF 32 Channel NVR with 4K Support and 2HDD Slot\n•32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O\n•12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 & CIF Recording Resolution\n•2 SATA HDD Support (10TB Capacity per Slot, Hard Disk Not Included)\n•512Mbps Throughput - 256 Uplink, 256 Downlink\n•ONVIF and Major Camera Brands Support MAKE & MODEL:Matrix - NVR3202X | 1 | Nos | |
287 | 288 | SITC of 6 TB Hard Drive for NVR MAKE & MODEL:Seagate | 1 | Nos | |
288 | 289 | SITC of 43" HD LED Display with minimum 2HDMI Port MAKE & MODEL:LG-43UT640S | 1 | Nos | |
289 | 290 | DATA (LAN wifi Networking) | |||
290 | 291 | Supplying and drawing of UTP 4 pair CAT 6LAN Cable on existing conduit MAKE:D-Link | 2000 | set | |
291 | 292 | SITC OF 24*Ports 10/100/1000Mbps PoE + 4 Ports 10G SFP+ Smart Managed Switch (370Watt, Surge 6KV) MAKE:D-Link - DGS-1250-28XMP | 1 | Nos | |
292 | 293 | SITC OF 24 Ports 10/100/1000Mbps + 4 10G Ports Layer-2 Managed Switch MAKE:D-Link - DGS-1510-28X | 1 | Nos | |
293 | 294 | SITC OF CAT6 UTP Copper Patch Panel-24 Port Loaded MAKE:D-Link | 2 | Nos | |
294 | 295 | SITC OF Controler based Wireless AC1300 Wave 2 Dual-Band PoE Access Point MAKE:D-Link - DAP-2610 | 7 | Nos | |
295 | 296 | SITC OF Wireless Controler Software and required PC MAKE:HP/DELL | 1 | Nos | |
296 | 297 | SITC OF CAT6 Dual Information Outlet with Backbox (SMB)MAKE:D-Link | 7 | Nos | |
297 | 298 | SITC OF CAT6 Single Information Outlet with Backbox (SMB)MAKE:D-Link | 7 | Nos | |
298 | 299 | SITC OF CAT6 UTP Copper Patch Cord Length-1Mtr MAKE:D-Link | 48 | Nos | |
299 | 300 | SITC OF CAT6 UTP Copper Patch Cord Length-2Mtr MAKE:D-Link | 21 | Nos | |
300 | 301 | SITC of 15U Wall Mount Rack with Accessories (FAN, PDU, Cable Manager & Screw Packet)MAKE:D-Link | 1 | Nos | |
301 | 302 | PART-III | |||
302 | 303 | Construction of Environmental Sustainability Plan | |||
303 | 304 | COVERED RCC DRAIN | |||
304 | 305 | a)Earth work in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge.= 432 cum b) Site Development, Land Scaping & Pathways= 820 cum c) Pond Landscaping= 44.87 cum x 6 (6 units) d) Organic Bio Waste Converter Shed= 29.35 cum (Total= 432 cum +820 cum +(44.87 cum x 6)+29.35 cum= 1550.57 cum) | 1550.57 | Cum | |
305 | 306 | a)Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties of all Materials, cost of all Labour,Sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge. (Measurement will be taken on finished compacted section only.) = 432 cum b) Site Development= 24 cum c) Pond Land Scaping= 21.62 cum x 6 (6 units) d) Organic Bio Waste Converter= 64.39 cum (Total= 72 cum + 24 cum +(21.62 cum x 6) +64.39 cum)=290.11 cum | 290.11 | Cum | |
306 | 307 | Providing and laying Plain Cement Concrete of M-10 (1:3:6) Grade in foundation and floors using 40 mm size crusher broken H.G Stone Metal and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete in layers not exceeeding 15cm thick in each layer to the required level, ramming, watering & curing etc complete including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge.= 72 cum b) Site development= 18 cum c) Organic Bio Waste Converter= 16.18 cum (Total= 72 cum +18 cum +16.18 cum= 106.18 cum) | 106.18 | Cum | |
307 | 308 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all kinds of R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary ncluding cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge. | |||
308 | 309 | R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas upt 4.3m height | 48 | Cum | |
309 | 310 | R.C.C wall | 108 | Cum | |
310 | 311 | RCC base | 54 | Cum | |
311 | 312 | Providing & fixing Thermo mechanically treated bars (Fe-500 D) Reinforcement bars of approved make for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyance of reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour, loading, unloading, labour cess, T&P, etc. required for the work complete for the work in all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) = 215 Qntl b) Pond Land scaping= 6.44 Qntl x 6 (6 units) c) Organic Bio Waste Converter= 9.34 Qntl Total= 215 Qntl + (6.44 Qntl x 6) + 9.34 Qntl= 262.98 Qntl) | 262.98 | Qntl | |
312 | 313 | Providing neat cement punning over plastered/ concrete surface including watering and curing complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge. | 1080 | Sqm | |
313 | 314 | Providing 6 mm. thick cement plaster to all RCC surface including closed deep chipping including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. | 1080 | Sqm | |
314 | 315 | Supplying and laying of factory made hydraulically pressed and mechanically compacted pre-cast interlocking UNI PAVER blocks of M-30 grade, 60mm thick over 50mm thick compacted bed of sand,compacting and proper laying of paver blocks in to the sand bedding layer through vibrator compaction by using plate vibrator,filling the joints with sand and finishing the surface including cutting of blocks at the edges with all labour and materials cost etc.work complete as per direction of Engineer-in-charge.= 780 sqm b) Site Development= 240 Sqm c) Pond Land Scaping= 32.50sqm x 6 (6 units) (Total= 480 sqm + 32.50sqm x 6+ 240 sqm= 915 sqm) | 915 | Sqm | |
315 | 316 | SITE DEVELOPMENT,LAND SCAPING & PATHWAYS (HARDSCAPE, SOFTSCAPES, GRASS PRAVERS) | |||
316 | 317 | Earth work in excavation of foundation in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depostiting the soil within initial lead of 50m including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. | 380 | Cum | |
317 | 318 | Providing & laying precast ,precured Cement Concrete [1: 1.5 :3 ] kerb stone [400 x300x150mm] with graded stone aggregates & fixing in position & pattern as shown in drawing with cement mortar of [1cement: 3 coarse sand] including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required including necessary excavation & filling side treanches etc. including cost of all materials, labour, lead, T&P etc. complete in all respects as per the direction of Engineer/ Architect-in-charge. | 400 | Rmt | |
318 | 319 | Supplying and laying of factory made hydraulically pressed and mechanically compacted pre-cast interlocking UNI PAVER blocks of M-30 grade, 60mm thick over 50mm thick compacted bed of sand,compacting and proper laying of paver blocks in to the sand bedding layer through vibrator compaction by using plate vibrator,filling the joints with sand and finishing the surface including cutting of blocks at the edges with all labour and materials cost etc.work complete as per direction of Engineer-in-charge. | 240 | Sqm | |
319 | 320 | Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge.= 240 nos. b) Pond Lanscaping= 32.50 nos. (Total= 240nos. + 32.50nos. = 272.50) | 272.5 | Nos | |
320 | 321 | Grassing with carpet grass(zoysia japonica) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed. In rows 5 cm. apart in either direction as per direction of Engineer-in-Charge. | 4500 | Sqm | |
321 | 322 | Excavation of pit measuring 2'6"x2'6"x2'6", removing the excavated soil to a suitable distance & refilling with mixture of good garden soil and decomposed cow dung manure in 1:4 for plantation as per the direction of Engineer-in-Charge. | 100 | Each | |
322 | 323 | Supplying of ornamental plants as per choice of the client, planting, applying fertilisers , pesticides, fungicides, weeding,watering as required for survival of the plant at least for 30 days complete as per specification and direction of Engineer-in-Charge. | 100 | Each | |
323 | 324 | Hedging with MURRAYA EXOTICA ,DURANTA, VARIAGATE etc. plants at the interval of 0.20mts including digging of treanch of size [0.45x 0.45 mt] & filling it with good garden soil & decomposed cowdung manure [1:1] after mixing properly. | 100 | Each | |
324 | 325 | POND LANDSCAPING | |||
325 | 326 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete in all respect excluding GST as directed by the Engineer- in- charge. (29.91cum x 6= 179.46cum for 6 units) | 179.46 | Cum | |
326 | 327 | Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with all labour, cess and T&P required for the work etc. complete in all respect. (9.92cum x 6= 59.52 cum for 6 units) | 59.52 | Cum | |
327 | 328 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1 cement: 6 sand), with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect excluding GST as directed by the Engineer-in-charge. | |||
328 | 329 | Foundation & Plinth b) Pond Landscaping= 8.49cum x 6 = 50.94cum for 6 units c) for Organic Bio Wate Converter= 13.29 cum | 64.23 | Cum | |
329 | 330 | Superstructure= 2.63 cum x 6 = 15.78 cum for 6 units | 15.78 | Cum | |
330 | 331 | 16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. excluding GST as directed by the Engineer- in -charge.(in side wall) (41.50cum x 6 = 249 cum for 6 units) | 249 | Sqm | |
331 | 332 | Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge. (100 sqm x 6 = 600 sqm for 6 units) | 600 | Sqm | |
332 | 333 | ORGANIC BIO WASTE CONVERTER SHED | |||
333 | 334 | CIVIL & STRUCTURE | |||
334 | 335 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. but excluding GST as required for the work complete as directed by the Engineer-in-charge | 19.57 | Cum | |
335 | 336 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete in all respect excluding GST as directed by the Engineer- in- charge. | 4.9 | Cum | |
336 | 337 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works( i.e footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, RCC Wall, Railings etc. ) of approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge. | |||
337 | 338 | Foundation & bases of column= 4.20cum b) for Pond Land Scaping= 21.60cum x 6 (for 6 units Total= 4.20cum + (21.60x6)cum= 133.80cum | |||
338 | 339 | GROUND FLOOR | 133.8 | Cum | |
339 | 340 | Plinth Beam | |||
340 | 341 | GROUND FLOOR | 2.35 | Cum | |
341 | 342 | Pedestal & Columns | |||
342 | 343 | GROUND FLOOR | 1.8 | Cum | |
343 | 344 | RCC wall (only for Pond Landscaping= 2.70cum 6 (for 6 units) | 16.2 | Cum | |
344 | 345 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment) | 82 | Sqm | |
345 | 346 | Providing Plinth Protection of 1 m Width with side drain of 300 mm all around the plinth area of the proposed building with an under layer of 75m.m thick Plain Cement Concrete of proportion (1:4:8) using 40mm size hard crusher broken black granite stone metal compacted over a consolidated rigid ground and top of 50 m.m thick Cement Concrete of proportion (1:2:4) with 12mm size hard crusher broken black granite stone chips laid to proper slope and gradient and top to be finished smooth with 12mm thick cement plaster in C.M(1:4) and protected the edges with Fly ash brick massonary walls ( using the Fly ash Bricks of crushing strength not less than 75Kg/Sqcm) (half brick masonry 125mm deep) in Cement Mortar (1:6) including excavation of required earth , cost , conveyance, loading, unloading, stacking,royalities & taxes of all Materials, cost all Labour,Sundries, T&P, watering, curing etc complete in all respect excluding GST as directed by the Engineer-in-charge. (Payment will be made on the finished item of composite works only,no separate payment will be made for any indivisual part portion of item of work).\n(Outside plinth area of Indoor hall ,Hostels,Staff quarter & Admin building etc.)\n | 67 | Sqm | |
346 | 347 | N.B: The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed. | BI01010001010000000000000515BI0100001158 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail