}

Development Of New A Site Retail Outlet At Old Showuba Village And Patkai Bridge On Lhs Towards Increasing Chainage On Dimapur Bypass Connecting Nh29 With Nh-36 Dist Dimapur State Nagaland, DIMAPUR-Nagaland

Indian Oil Corporation Limited-IOCL has published Development Of New A Site Retail Outlet At Old Showuba Village And Patkai Bridge On Lhs Towards Increasing Chainage On Dimapur Bypass Connecting Nh29 With Nh-36 Dist Dimapur State Nagaland. Submission Date for this Tender is 27-01-2021. Land Development Tenders in DIMAPUR Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

26596466
Development Of New A Site Retail Outlet At Old Showuba Village And Patkai Bridge On Lhs Towards Increasing Chainage On Dimapur Bypass Connecting Nh29 With Nh-36 Dist Dimapur State Nagaland
National Competitive Bid
Indian
Nagaland
DIMAPUR
27-01-2021

Tender Details

Development Of New A Site Retail Outlet At Old Showuba Village And Patkai Bridge On Lhs Towards Increasing Chainage On Dimapur Bypass Connecting Nh29 With Nh-36 Dist Dimapur State Nagaland

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 1.32 Crore /-

BOQ Items

Name of Work: Development of New “A” Site Retail Outlet at Old Showuba Village and Patkai Bridge on LHS towards increasing Chainage on Dimapur Bypass connecting NH29 with NH-36 , Dist: Dimapur, State: Nagaland. GST applicable will bw payable extra.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Driveway BI01010001010000000000000515BI0100001112
2 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001113
3 3 i) All kinds of Soil BI01010001010000000000000515BI0100001114 14.4 M3
4 4 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001115
5 5 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001116 10.8 M3
6 6 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001117
7 7 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001118 540 KG
8 8 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001119
9 9 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001120 115.2 M2
10 10 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001121
11 11 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001122 6.48 M3
12 12 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001123
13 13 i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired BI01010001010000000000000515BI0100001124 214.5 M3
14 14 Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer BI01010001010000000000000515BI0100001125 1380 M3
15 15 Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. BI01010001010000000000000515BI0100001126 690 M2
16 16 Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) BI01010001010000000000000515BI0100001127
17 17 ii) M40 grade 80 mm thick reflective type Lacquered finish BI01010001010000000000000515BI0100001128 690 M2
18 18 Installation of MPDs BI01010001010000000000000515BI0100001129
19 19 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001130
20 20 i) All kinds of Soil BI01010001010000000000000515BI0100001131 7.2 M3
21 21 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001132
22 22 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001133 18.05 M3
23 23 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001134
24 24 iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001135 2 M3
25 25 ix) 1:4:8(1 Cement :4 Fine Sand : 8 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001136 2.73 M3
26 26 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001137
27 27 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001138 4.5 M2
28 28 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001139
29 29 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001140 12.85 M3
30 30 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001141
31 31 iii) Granite of any colour and shade having Area of slab upto 0.50 sqm BI01010001010000000000000515BI0100001142 28 M2
32 32 Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. BI01010001010000000000000515BI0100001143
33 33 ii) Granite work BI01010001010000000000000515BI0100001144 38 M
34 34 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001145 90 M
35 35 Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve BI01010001010000000000000515BI0100001146
36 36 iii) S/I Screwed type GM Ball Valve of 50 mm dia BI01010001010000000000000515BI0100001147 4 EA
37 37 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump BI01010001010000000000000515BI0100001148
38 38 i) 2 product - 4 nozzle MPPs/MPDs BI01010001010000000000000515BI0100001149 2 EA
39 39 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001150
40 40 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km BI01010001010000000000000515BI0100001151 1 LS
41 41 ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001152 660 KM
42 42 xii) MPD/MPP pumps upto 2 nos., 0-30 Km BI01010001010000000000000515BI0100001153 1 M3
43 43 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001154 660 KM
44 44 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge BI01010001010000000000000515BI0100001155 2 M3
45 45 CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings. BI01010001010000000000000515BI0100001156
46 46 iii) 500VA CVT BI01010001010000000000000515BI0100001157 3 M3
47 47 SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer of approved makes,(Range - 180 - 250 minimum) shall be provided for Individual dispensing pump as per IE Regulation and as per specification BI01010001010000000000000515BI0100001158
48 48 iv) 5KVA stabilizer BI01010001010000000000000515BI0100001159 3 M3
49 49 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001160 30 M
50 50 Construction of Canopy BI01010001010000000000000515BI0100001161
51 51 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001162
52 52 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001163 44.8 M3
53 53 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001164
54 54 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001165 1333 M3
55 55 Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 80 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001166 12 M3
56 56 Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil BI01010001010000000000000515BI0100001167 13.52 M3
57 57 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001168
58 58 i) All kinds of Soil BI01010001010000000000000515BI0100001169 72.08 M3
59 59 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001170
60 60 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001171 5.4 M3
61 61 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001172
62 62 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001173 5.104 M3
63 63 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001174
64 64 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001175 14.032 M3
65 65 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001176 8640 KG
66 66 Providing and fixing  Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. BI01010001010000000000000515BI0100001177
67 67 i) Profile Sheet for roofing BI01010001010000000000000515BI0100001178 192 M2
68 68 iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) BI01010001010000000000000515BI0100001179 56 M
69 69 Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) BI01010001010000000000000515BI0100001180 32 M
70 70 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001181
71 71 ii) 110 mm diameter BI01010001010000000000000515BI0100001182 32 M
72 72 Providing and fixing  150F/200F flush panel,(pre-coated steel) False Ceiling made of  Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of  thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. BI01010001010000000000000515BI0100001183 192 M2
73 73 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001184 700 M2
74 74 Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001185 6 EA
75 75 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001186
76 76 iv) 300 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001187 50 M
77 77 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : BI01010001010000000000000515BI0100001188
78 78 vi) 32mm dia x 1125mm long with 100 mm dia x 8 mm thick plate BI01010001010000000000000515BI0100001189 48 EA
79 79 Side Drain BI01010001010000000000000515BI0100001190
80 80 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including taking out and disposal of excavated earth within site and lift upto 1.5 m, disposed soil to be levelled and neatly dressed as directed by Engineer-in-charge. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600. BI01010001010000000000000515BI0100001191 128.25 M2
81 81 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001192
82 82 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001193 9.214 M3
83 83 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001194
84 84 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001195 27.945 M3
85 85 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001196
86 86 i) 12mm Cement plaster of mix 1:4 (1 cement: 4 coarse sand) BI01010001010000000000000515BI0100001197 448.2 M2
87 87 Providing Neat cement punning BI01010001010000000000000515BI0100001198 448.2 M2
88 88 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001199 54 M2
89 89 Buffer strip BI01010001010000000000000515BI0100001200
90 90 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001201 6.215 M2
91 91 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including taking out and disposal of excavated earth within site and lift upto 1.5 m, disposed soil to be levelled and neatly dressed as directed by Engineer-in-charge. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600. BI01010001010000000000000515BI0100001202 16 M2
92 92 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001203
93 93 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001204 1.52 M3
94 94 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001205
95 95 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001206 6.9 M3
96 96 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001207
97 97 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001208 45.2 M2
98 98 Providing Neat cement punning BI01010001010000000000000515BI0100001209 45.2 M2
99 99 Installation of tanks BI01010001010000000000000515BI0100001210
100 100 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001211
101 101 i) All kinds of Soil BI01010001010000000000000515BI0100001212 8.25 M3
102 102 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001213
103 103 ix) 1:4:8(1 Cement :4 Fine Sand : 8 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001214 3.384 M3
104 104 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001215
105 105 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001216 30.48 M2
106 106 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001217
107 107 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001218 7.29 M3
108 108 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001219
109 109 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001220 91.2 M2
110 110 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001221 65 M2
111 111 Providing Neat cement punning BI01010001010000000000000515BI0100001222 91.2 M2
112 112 Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. BI01010001010000000000000515BI0100001223 548 KG
113 113 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001224
114 114 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001225 4.209 M3
115 115 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001226
116 116 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001227 350 KG
117 117 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001228
118 118 iv) S/L Welded U/G HD MS Pipes of 40mm dia with fittings,doping BI01010001010000000000000515BI0100001229 12 M
119 119 Supply, fabrication, laying and testing of MS, BLACK, ERW, Welded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications BI01010001010000000000000515BI0100001230
120 120 iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting BI01010001010000000000000515BI0100001231 12 M
121 121 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001232
122 122 iii) 15/20 KL Tank with fittings : 0 - 30 Km BI01010001010000000000000515BI0100001233 2 LS
123 123 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km BI01010001010000000000000515BI0100001234 600 KM
124 124 Supplying and installation of the following threaded BI01010001010000000000000515BI0100001235
125 125 i) 80 mm dia Aluminium camlock coupling - Male only BI01010001010000000000000515BI0100001236 2 EA
126 126 Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. BI01010001010000000000000515BI0100001237 1 EA
127 127 Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. BI01010001010000000000000515BI0100001238
128 128 iii) Supply & installation of U type CS bend on vent pipe of 40 mm dia BI01010001010000000000000515BI0100001239 1 EA
129 129 Providing stainless steel wire mesh 32 SWG, 11 mesh per linear cm of of non corrosive metal in two layers on existing vent hoods ‘U’ type (on both ends) including brazing, etc. complete BI01010001010000000000000515BI0100001240
130 130 iii) 32SWG SS wire mesh both sides of existing U vent hood 40mm dia BI01010001010000000000000515BI0100001241 1 EA
131 131 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001242
132 132 ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping BI01010001010000000000000515BI0100001243 8 M
133 133 Installation of supplied 10 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 BI01010001010000000000000515BI0100001244
134 134 ii) In earth pit with RCC matt raft as per standard Drg. ENG/306 BI01010001010000000000000515BI0100001245 2 LS
135 135 Sales building and Toilet block BI01010001010000000000000515BI0100001246
136 136 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001247
137 137 i) All kinds of Soil BI01010001010000000000000515BI0100001248 70.72 M3
138 138 Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil BI01010001010000000000000515BI0100001249 55.397 M3
139 139 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001250
140 140 viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001251 7.294 M3
141 141 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001252
142 142 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001253 12.85 M3
143 143 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : BI01010001010000000000000515BI0100001254
144 144 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001255 13.308 M3
145 145 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001256
146 146 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001257 57.06 M2
147 147 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001258 47.88 M2
148 148 iv) Lintels, beams plinth beams,girders bressumers and cantilevers BI01010001010000000000000515BI0100001259 54.6 M2
149 149 v) Columns, Pillars, Piers, Abutments, Posts and Struts. BI01010001010000000000000515BI0100001260 37.44 M2
150 150 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001261
151 151 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001262 10.422 M3
152 152 iii) Brick work in Cement mortar 1:4 (1 cement: 4 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL BI01010001010000000000000515BI0100001263 11.72 M3
153 153 Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified BI01010001010000000000000515BI0100001264
154 154 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 BI01010001010000000000000515BI0100001265 18 M2
155 155 iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 BI01010001010000000000000515BI0100001266 3.39 M2
156 156 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. BI01010001010000000000000515BI0100001267 39.69 M2
157 157 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. BI01010001010000000000000515BI0100001268 9 M2
158 158 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001269
159 159 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001270 195.44 M2
160 160 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete BI01010001010000000000000515BI0100001271 230 M2
161 161 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001272 230 M2
162 162 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. BI01010001010000000000000515BI0100001273 21 M2
163 163 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001274 16.5 M2
164 164 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: BI01010001010000000000000515BI0100001275
165 165 i) W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001276 3 EA
166 166 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : BI01010001010000000000000515BI0100001277
167 167 ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap BI01010001010000000000000515BI0100001278 3 EA
168 168 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. - 15 mm nominal bore BI01010001010000000000000515BI0100001279 3 EA
169 169 Providing and fixing C.P. brass stop cock (concealed) of standard design & of approved make conforming to IS:8931 - 15 mm nominal bore. BI01010001010000000000000515BI0100001280 6 EA
170 170 Providing and fixing toilet paper holder : BI01010001010000000000000515BI0100001281
171 171 i) C.P. brass BI01010001010000000000000515BI0100001282 3 EA
172 172 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank BI01010001010000000000000515BI0100001283 1000 L
173 173 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall BI01010001010000000000000515BI0100001284
174 174 i) 15 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001285 30 M
175 175 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001286 30 M
176 176 iv) 32 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001287 12 M
177 177 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. BI01010001010000000000000515BI0100001288 3 EA
178 178 Painting top of roofs with residual type petroleum bitumen of grade VG10 of approved quality at 17kg per10sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil complete. BI01010001010000000000000515BI0100001289 47.88 M2
179 179 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I.cover with frame of 300 x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : BI01010001010000000000000515BI0100001290
180 180 v) 180x150 mm size P type with common burnt clay bricks of class Designation 7.5 BI01010001010000000000000515BI0100001291 3 EA
181 181 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001292
182 182 ii) 110 mm diameter BI01010001010000000000000515BI0100001293 6 M
183 183 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001294 1 EA
184 184 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001295 3 EA
185 185 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. BI01010001010000000000000515BI0100001296 4 EA
186 186 Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : BI01010001010000000000000515BI0100001297
187 187 i) 125 mm BI01010001010000000000000515BI0100001298 10 EA
188 188 Providing & fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : BI01010001010000000000000515BI0100001299
189 189 i) 200x10 mm BI01010001010000000000000515BI0100001300 4 EA
190 190 ii) 100x10 mm BI01010001010000000000000515BI0100001301 6 EA
191 191 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): BI01010001010000000000000515BI0100001302
192 192 i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) BI01010001010000000000000515BI0100001303 15 M2
193 193 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) BI01010001010000000000000515BI0100001304
194 194 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections BI01010001010000000000000515BI0100001305 120 KG
195 195 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001306
196 196 i) All kinds of Soil BI01010001010000000000000515BI0100001307 35 M3
197 197 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001308
198 198 x) 1:5:10(1 Cement :5 Coarse Sand : 10 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001309 5 M3
199 199 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001310
200 200 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001311 5 M3
201 201 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001312
202 202 i) 12mm Cement plaster of mix 1:4 (1 cement: 4 coarse sand) BI01010001010000000000000515BI0100001313 50 M2
203 203 Providing Neat cement punning BI01010001010000000000000515BI0100001314 50 M2
204 204 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001315
205 205 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001316 3.6 M3
206 206 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001317
207 207 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001318 324 KG
208 208 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001319
209 209 iii) 160 mm diameter PVC Rain water pipe BI01010001010000000000000515BI0100001320 5 M
210 210 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. BI01010001010000000000000515BI0100001321
211 211 vi) 50 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001322 4 M
212 212 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001323 30 KG
213 213 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: BI01010001010000000000000515BI0100001324
214 214 iii) Inside dimensions 600x 850 mm and 45 cm deep for pipeline with 3 or more inlets, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001325 2 EA
215 215 Electrification BI01010001010000000000000515BI0100001326
216 216 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. BI01010001010000000000000515BI0100001327
217 217 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. BI01010001010000000000000515BI0100001328 1 EA
218 218 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001329
219 219 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001330 30 M
220 220 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001331 40 M
221 221 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire BI01010001010000000000000515BI0100001332 30 M
222 222 Supply and fixing of following Electrical fittings /fixtures BI01010001010000000000000515BI0100001333
223 223 i) 5 Amp Piano type switch BI01010001010000000000000515BI0100001334 12 EA
224 224 iii) 5 Amp Piano type 3 pin socket BI01010001010000000000000515BI0100001335 6 EA
225 225 iv) 15Amp modular type switch BI01010001010000000000000515BI0100001336 4 EA
226 226 v) 15Amp modular type 6 pin socket BI01010001010000000000000515BI0100001337 4 EA
227 227 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001338
228 228 xii) Fan Regulator of stepped modular type BI01010001010000000000000515BI0100001339 3 EA
229 229 vi) 12 module frame BI01010001010000000000000515BI0100001340 1 EA
230 230 iv) 6 module frame BI01010001010000000000000515BI0100001341 4 EA
231 231 ii) 3 module frame BI01010001010000000000000515BI0100001342 6 EA
232 232 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001343
233 233 i) 50 x 10mm G.I. Strip BI01010001010000000000000515BI0100001344 90 M
234 234 iii) 50 x 6 mm G.I. Strip BI01010001010000000000000515BI0100001345 30 M
235 235 v) 25 x 3 mm GI strip BI01010001010000000000000515BI0100001346 50 M
236 236 vi) 8 S.W.G. G.I. Wire (bare) BI01010001010000000000000515BI0100001347 150 M
237 237 Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. BI01010001010000000000000515BI0100001348
238 238 i) for 2.5 sq.mm. cable entry size with 9 terminals BI01010001010000000000000515BI0100001349 6 EA
239 239 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001350
240 240 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001351 600 M
241 241 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001352 600 M
242 242 ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge BI01010001010000000000000515BI0100001353 3 EA
243 243 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: BI01010001010000000000000515BI0100001354
244 244 iii) 1200 mm sweep BI01010001010000000000000515BI0100001355 3 EA
245 245 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001356 6 EA
246 246 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001357 6 EA
247 247 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. BI01010001010000000000000515BI0100001358
248 248 i) For cables 2.5 to 4 sqmm XLPE / AYFY BI01010001010000000000000515BI0100001359 6 EA
249 249 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : BI01010001010000000000000515BI0100001360
250 250 iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) BI01010001010000000000000515BI0100001361 10 EA
251 251 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001362 10 EA
252 252 Hoarding BI01010001010000000000000515BI0100001363
253 253 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001364
254 254 i) All kinds of Soil BI01010001010000000000000515BI0100001365 10 M3
255 255 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. BI01010001010000000000000515BI0100001366
256 256 i) For cables 2.5 to 4 sqmm XLPE / AYFY BI01010001010000000000000515BI0100001367 4 EA
257 257 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001368
258 258 ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001369 3 M3
259 259 viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001370 2 M3
260 260 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001371 1595 KG
261 261 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001372 95 M2
262 262 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001373
263 263 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001374 90 M
264 264 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001375 90 M
265 265 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001376
266 266 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001377 5 EA
267 267 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001378 3 EA
268 268 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001379 5 EA
269 269 Digital Tyre Inflator BI01010001010000000000000515BI0100001380
270 270 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001381
271 271 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001382 1.5 M3
272 272 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001383
273 273 viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001384 1.5 M3
274 274 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001385
275 275 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001386 4 M2
276 276 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001387
277 277 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001388 1.5 M3
278 278 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001389 150 KG
279 279 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001390
280 280 i) All kinds of Soil BI01010001010000000000000515BI0100001391 5 M3
281 281 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) BI01010001010000000000000515BI0100001392 1 EA
282 282 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001393
283 283 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001394 80 M
284 284 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001395
285 285 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001396 4 EA
286 286 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. BI01010001010000000000000515BI0100001397
287 287 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001398 60 M
288 288 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001399
289 289 iii) Granite of any colour and shade having Area of slab upto 0.50 sqm BI01010001010000000000000515BI0100001400 3.5 M2
290 290 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001401 10 M2
291 291 Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins,rafters & trusses & including cutting to size & shape wherever required:- 1.00mm thick G.S. Sheet with zinc coating not less than 275gm/m² BI01010001010000000000000515BI0100001402 3 M2
292 292 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: BI01010001010000000000000515BI0100001403
293 293 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works BI01010001010000000000000515BI0100001404 1 EA
294 294 Monolith foundation BI01010001010000000000000515BI0100001405
295 295 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001406
296 296 i) All kinds of Soil BI01010001010000000000000515BI0100001407 11 M3
297 297 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001408
298 298 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001409 0.22 M3
299 299 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001410
300 300 iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001411 0.72 M3
301 301 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001412
302 302 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001413 5.56 M3
303 303 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001414
304 304 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001415 16.95 M2
305 305 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001416
306 306 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001417 262.48 KG
307 307 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001418
308 308 vii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:3 (1 cement : 3 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001419 1.423 M2
309 309 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001420
310 310 iii) Granite of any colour and shade having Area of slab upto 0.50 sqm BI01010001010000000000000515BI0100001421 4.03 M2
311 311 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : BI01010001010000000000000515BI0100001422
312 312 v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate BI01010001010000000000000515BI0100001423 12 EA
313 313 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001424
314 314 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001425 70 M
315 315 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001426
316 316 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001427 4 EA
317 317 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001428 25 M
318 318 Supplying and providing 100mm square hensel weather proof junction box for emblem pole/ light pole/yard light BI01010001010000000000000515BI0100001429 1 EA
319 319 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001430 2 EA
320 320 Culvert BI01010001010000000000000515BI0100001431
321 321 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001432
322 322 i) All kinds of Soil BI01010001010000000000000515BI0100001433 114 M3
323 323 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001434
324 324 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001435 5.88 M3
325 325 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001436
326 326 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001437 35.82 M3
327 327 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001438
328 328 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001439 4500 KG
329 329 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001440 4528 KG
330 330 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001441 33.6 M2
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail