}

Supply And Installation Testing Commissioning ( Itc ) Of Battery Bank And Buyback Of Existing Battery Bank, IOCL Gujarat Refinery-Gujarat

Indian Oil Corporation Limited has published Supply And Installation Testing Commissioning ( Itc ) Of Battery Bank And Buyback Of Existing Battery Bank. Submission Date for this Tender is 03-02-2021. Chemical Supply Tenders in IOCL Gujarat Refinery Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

26596295
Supply And Installation Testing Commissioning ( Itc ) Of Battery Bank And Buyback Of Existing Battery Bank
Tender
Indian
Gujarat
Iocl Gujarat Refinery
03-02-2021

Tender Details

Supply And Installation Testing Commissioning ( Itc ) Of Battery Bank And Buyback Of Existing Battery Bank , List Of Items , Battery Bank Technical Details Rating : 100 Ah , 110 V , 1 No . Kph-100P 1 Battery Bank : No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-1014-Bb-Bc-Crtl ( Sru-Cetp ) Specifications : 90Ah , 110V , Ni-Cd ( Sab-Nife ) , Kph-90P , 87 Cell Purpose : 110 V Dc For Battery Charger , Battery Bank Technical Details 1 Battery Bank : Rating : 75 Ah , 110 V , Kph-75P No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-1014-Bb-Bc-Inst ( Sru-Cetp ) Specifications : 60Ah , 110V , Ni-Cd ( Sab-Nife ) , Kph-60P , 87 Cell Purpose : 110 V Dc For Battery Charger , Battery Bank Technical Details 1 Battery Bank : Rating : 210 Ah , 110 V , Kpm-210P No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-0008-Bb-Bc ( Sru-Cetp ) Specifications : 210Ah , 110V , Ni-Cd ( Sab-Nife ) , Kpm-210P , 87 Cell Purpose : 110 V Dc For Battery Charger , Battery Bank Technical Details 1 Battery Bank : Rating : 150 Ah , 110 V , Kpl-150P : 1 No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-0010-Bb-Bc-Inst ( Sru-Cetp ) Specifications : 155Ah , 110V , Ni-Cd ( Sab-Nife ) , Kpl-155P , 85 Cell Purpose : 110 V Dc For Battery Charger , Battery Bank Technical Details 1 Battery Bank : Rating : 42 Ah , 120 V , Smf Type No . Of Cell : 10 Nos . Battery Bank : 120 Volts Nominal Cell Voltage : 12 Volts Battery Bank To Be Supplied As Per Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-Ts-Bb-Bc-Ss7b ( Township ) Specifications : 42Ah , 12V , Smf Type , 9 No . Smf Battery Purpose : 110 V Dc For Battery Charger , Battery Bank Technical Details 1 Battery Bank : Rating : 34 Ah , 360 V , Kph-34P No . Of Cell : 288 + 5 Nos . Spare Cells Battery Bank : 360 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-0008-Bb-Ups ( Sru-Cetp ) Specifications : 34Ah , 360V , Ni-Cd ( Amco ) , Kph-34P , 288 Cell , Battery Bank Technical Details 1 Battery Bank : Rating : 26 Ah , 120 V , Smf Type No . Of Cell : 10 Nos . Battery Bank : 120 Volts Nominal Cell Voltage : 12 Volts Battery Bank To Be Supplied As Per Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-Ts-Bb-Bc-Ss7d ( Township ) Specifications : 26Ah , 120V , Smf Type , 10 No . Smf Battery Purpose : 120 V Dc For Battery Charger , Battery Bank Technical Details Rating : 300 Ah , 110 V , Kpm-300P 2 Battery Bank : No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) 9030-0103-Bb-Bc-Dcemg ( Au3 ) Specifications : 300Ah , 110V , Pb-Acid , 55 Cell , Hbl Power System 2 ) 9030-0103-Bb-Bc ( Au3 ) Specifications : 300Ah , 110V , Pb-Acid , 55 Cell , Exide , Battery Bank Technical Details Rating : 190 Ah , 110 V , Kph-190P 1 Battery Bank : No . Of Cell : 87 + 5 Nos . Spare Cells Battery Bank : 110 Volts Nominal Cell Voltage : 1 . 2 Volts Battery Bank To Be Supplied As Per Above Specification And Specifications Attached As Annexure A Technical Specification For Stationary Nickel Cadmium Batteries Above Specification Along With Standard Accessories . Specification Of The Existing Battery Bank ( To Be Taken By Vendor Under Buy Back ) Location Of Battery Bank : 1 ) Au-I/Ii/Cru Instrument Supply Specifications : 170Ah , 110V , Ni-Cd , 87 Cell , Snps

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail