Military Engineer Services-MES has published Provision Of Revenue Work For Renovation Of Officers Family Ward In Bldg No . T 52 At Mh Provn Of Tiling In Dsoi Bldg No . T 35 I And Ii At Temple Lane Provn Of Minor Works For Addn Altn Of Toilet And Bath Room Of Bldg No . T 14 3 And T 12A 1 2 3 A. Submission Date for this Tender is 08-02-2021. Building Repair Tenders in GE RAMGARH Jharkhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 25-Jan-2021 | OTHER | Other | 03-02-2021 |
2 | 27-Jan-2021 | DATE | Date | 08-02-2021 |
Name of Work : Provn of Revenue work for renovation of Officers Family ward in Bldg No. T-52 at MH, Provn of Tiling in DSOI Bldg No. T-35/I & II at Temple Lane, Provn of Minor works for Addn/Altn of Toilet and Bath Room of Bldg No. T-14/3 & T-12A/1,2,3 at MES MD area, Provn of Hard standing near Bldg No. P-530, Provn of Soakage well (Size 3.0m, dia 3.0 m depth) in Trg Area at 2 Camp SRC, Provn of RCC jali on boundary wall of Offrs Md Accn Bldg No. T-1, Temple Lane, Provn of 03x Urinal Pot alongwith water facilities at Bldg No. T-16, 20 Camp SRC, Addn/Altn of toilet and Bath room in Bldg No. T-2 at Stn HQ, Provn of 06x Geyser for Bldg No. T-1, T-2 & T-19 at 20 Camp SRC, and Rewiring in Sikh House Bldg No. P-2 at 20 Camp Golf Area SRC Ramgarh Cantt under GE Ramgarh. | |||||
---|---|---|---|---|---|
Sl. No. | Description of Items | Item Code / Make | Quantity/ Nos of Units | Units | |
1 | 1 | Roughening surface of old concrete floor by picking, sweeping washing down with water to remove dust etc., and brushing neat cement slurry with 3 Kg of cement per square metre, complete all as specified and as directed. (37+6) | 1 | 43 | SQM |
2 | 2 | Brushing neat cement slurry with 3 Kg of cement per square metre, complete all as specified and as directed. | 2 | 37 | SQM |
3 | 3 | M & L for 9-10 mm thick light colored vitrified ceramic tiles of size as in floor, n.exc 0.36 Sqm set and jointed in neat cement slurry and pointed in coloured cement to match over and including 20mm thick screed bed in cement mortar (1:4), complete all as specified and as directed. (26+69) | 3 | 95 | SQM |
4 | 4 | All as per item No. 3 here-in-before but in skirting including 10mm thick rendering in cement mortar (1:3) (4+7) | 4 | 11 | SQM |
5 | 5 | M & L joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular )area of each tile exe.0.11 sqm but n.exe.0.18 sqm, in floor including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed. (11+ 6) | 5 | 17 | SQM |
6 | 6 | M & L for cement concrete type B1, 1:2:4 (using 12.5 mm graded aggregate) in levelling courses, coping, window cill etc., complete all as specified and directed. (1+0.70+0.5+0.40) | 6 | 2.6 | CUM |
7 | 7 | Taking down cement plaster of any description and in any position including raking out joints, hacking for key scrubbing down with water etc and removing of debris from site, complete all as directed. (25+21) | 7 | 46 | SQM |
8 | 8 | M & L for glazed ceramic coloured tiles 300x250X 7/450x300x7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including rendering 10mm thick with cement mortar (1:3) on fair faces of brick work to received tiles in vertical, complete all as specified and directed. | 8 | 21 | SQM |
9 | 9 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) including cover fillet, complete all as specified and directed. | 9 | 26 | SQM |
10 | 10 | M & L for providing aluminium snap grid frame work for false ceiling with size 605x605 mm, using Main and cross tee of size 36.5mm x 25mm x 1.4mm, weighing 0.24 Kg/RM and 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM respectively. The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mm x 25 mm x 2 mm weighing 0.36 Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia mild steel wire/GI wire, J bolts, nuts and washers as per manufacturer's, complete all as specified and as directed. | 10 | 26 | SQM |
11 | 11 | M & L for 4mm thick non asbestos fibre designer cement building board fixed or laid/inserted to timber/GI/Aluminium framework with screws, complete all as specified and as directed. | 11 | 26 | SQM |
12 | 12 | M & L for preparation of old painted wooden based surfaces of any description not otherwise described over 10cm width or girth applying one coat synthetic enamel paint (ordinary tint), any colour, complete all as specified and directed by Engr-In-Charge . | 12 | 10 | SQM |
13 | 13 | Taking down chowkhats or frames with shutter (without taking of shutter from the frame) of any description n.exc 1.5 Sqm each, complete all as specified and directed by Engr-In-Charge . (1+1+6) | 13 | 8 | EACH |
14 | 14 | Taking down chowkhats or frames with shutter (without taking of shutter from the frame) of any description exc 1.5 Sqm and n.exc 4 Sqm each, complete all as specified and directed by Engr-In-Charge . | 14 | 2 | EACH |
15 | 15 | M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed. (1+5+3+3+2) | 15 | 14 | CUM |
16 | 16 | M & L for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and fair (without using extra or cement), complete all as specified and directed.(8+16) | 16 | 24 | SQM |
17 | 17 | M & L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. (4+40+80+16) | 17 | 140 | SQM |
18 | 18 | M & L for preparation of new plastered wall surfaces applying two coats of wall care putty to make the entire surface free from undulations, complete all as specified and directed. | 18 | 4 | SQM |
19 | 19 | M & L for completely removal of existing treatment of old wall and applying two coats of wall care putty on wall surface including preparation of surfaces to making the surface even and smooth to receive finishes, complete all as specified and as directed. | 19 | 120 | SQM |
20 | 20 | M & L for preparation of new wall putty finish surfaces, priming plastered and other surfaces and applying two coats of oil bound distermper over a coat of alkali resistant primer, complete all as specified and as directed. | 20 | 124 | SQM |
21 | 21 | M & L for solid PVC door frame of size 50mm x 47 mm made out of 5m plain colour PVC sheet reinforced with MS square tube, fixing in opening, complete all as specified and as directed. (4.7+4.5+27) | 21 | 36.2 | RM |
22 | 22 | M & L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rain on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement fixing with the frame at site as per manufacturerer's instructions, complete all as specified and directed. (1.2+1.3+8) | 22 | 10.5 | SQM |
23 | 23 | S & F Aluminium anodised handles 125 mm long of extruded section, complete all as specified and as directed. (2+2+16) | 23 | 20 | EACH |
24 | 24 | S & F Aluminium anodised barrel tower bolts 200 mm long of extruded section, complete all as specified and as directed. (2+2+16) | 24 | 20 | EACH |
25 | 25 | Taking up and down GI tubing including GI fittings complete from trench/wall/ceiling/floor suitable for 15mm dia pipe, including cleaning for refixing of the same, complete all as specified and as directed. (10+10) | 25 | 20 | RM |
26 | 26 | Taking up and down GI tubing including GI fittings complete from trench/wall/ceiling/floor suitable for 20mm dia pipe, including cleaning for refixing of the same, complete all as specified and as directed. | 26 | 5 | RM |
27 | 27 | S & F for GI tubing medium grade including all types of fittings of ISI marked laid in walls/ceiling/floor suitable for 15 mm bore, complete all as specified and as directed. (10+10+5) | 27 | 25 | RM |
28 | 28 | S & F for GI tubing medium grade including all types of fittings of ISI marked laid in walls/ceiling/floor suitable for 20 mm bore, complete all as specified and as directed. (5+5) | 28 | 10 | RM |
29 | 29 | S & F in repair 15mm dia bore bib tap, chromium plated, fancy type, long shank with crutch butterfly handle screwed down, screwed for iron pipe or for brass ferrule etc., complete all as specified and directed. (1+4) | 29 | 5 | EACH |
30 | 30 | S & F in repairs stop valve chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions of bore 15mm complete all as specified and directed and as directed. (4+4) | 30 | 8 | EACH |
31 | 31 | S & F in repairs Two way angle cock chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions of bore 15mm complete all as specified and directed and as directed. | 31 | 1 | EACH |
32 | 32 | S & F 15mm dia central hole hasin mixer with U shaped round catered spout with 450 mm long braided hoses (Hot & Cold), complete all as specified and as directed. | 32 | 1 | EACH |
33 | 33 | S & F 15mm dia Brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed. | 33 | 1 | EACH |
34 | 34 | S & F in repairs 15 mm dia concealed type stop valve fancy type chromium plated etc., complete all as specified and as directed. (1+2) | 34 | 3 | EACH |
35 | 35 | S & F in repair brass chromium plated shower rose 125 mm size fancy type with or without swivel joint fixed to iron pipe etc., complete all as specified and as directed. (1+20 | 35 | 3 | EACH |
36 | 36 | M & L 600x450 mm beveled edge looking mirror 5 mm thick selected quality glass mounted on 6 mm thick AC building board fixed to wall by wooden plug with chromium plated brass screw and cup washer fixed as in repair complete all as specified and directed. (1+1+1) | 36 | 3 | EACH |
37 | 37 | S & F in repairs for vitreous china wash down water closet, pedestal pattern white (excluding fixing bolt, flushing cistern and flush pipe) but including P or S trap connection to drain or outgoing pipe , complete all as specified and directed. | 37 | 1 | EACH |
38 | 38 | S & F in repair vitreous China wash hand basin, white, flat back, size 550X400mm including chain and plug, and porcelain stopper, cast iron brackets, waste pipe including cutting for and pinning in ends of brackets or erecting stand and making good disturbed surfaces in CM (1:3), complete all as specified and directed.Make:- Hindware/Parryware/Cera or of equivalent approved make. (1+1+2) | 38 | 4 | EACH |
39 | 39 | S & F in repair PVC connection 15 mm size with PTMT nuts of length 450, complete all as specified and as directed. (4+4+4) | 39 | 12 | EACH |
40 | 40 | S & F CP towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and as directed. (1+2) | 40 | 3 | EACH |
41 | 41 | S & F in repair flushing cistern low level, PVC 10 lit capacity syphon action type, valveless with inlet ball valve, float valve and handle including brackets fixed to wall and flush pipe, complete all as specified and as directed. (1+1) | 41 | 2 | EACH |
42 | 42 | S & F in repair, plastic water closet seat cover, closed pattern with flat bottom, and cover and mild steel chormium plated or aluminum hinging device for pedestal pattern Water Closet white colour, complete all as specified and as directed. | 42 | 1 | EACH |
43 | 43 | S & F vitreous China urinal, half stall type (back to corner wall type) including providing and fixing plug, bedding urinal against wall in cement mortar (1:2) securing urinal to plug with and including 60 mm brass long screw, pointing around urinal back in cement mortar, flush pipe, waste pipe, waste fittings, grating and union for discharge, complete all as specified and as directed.(1+3) | 43 | 4 | EACH |
44 | 44 | S & F in repair for 32 mm bore waste coupling of PTMT (half or full threaded) (min weight 45 gms), complete all as specified and as directed. | 44 | 2 | EACH |
45 | 45 | S & F in repair 32 mm bore low density polyethylene (LDPE) pipes of pressure rating 6 Kgf/sqm, complete all as specified and as directed. | 45 | 2 | EACH |
46 | 46 | M & L for 75mm dia PVC(SWR) floor trap, plain with steel grating including jointing with solvent cement, complete all as specified and as directed. (2+2+3+1) | 46 | 8 | EACH |
47 | 47 | M & L for PVC(SWR) pipes 75 mm bore single socketed in any length with rubber ring joint laid in trenches/floor, complete all as specified and as directed. (3+2+3+3) | 47 | 11 | RM |
48 | 48 | M & L for PVC(SWR) pipes 110 mm bore single socketed in any length with rubber ring joint laid in trenches/floor, complete all as specified and as directed. (3+1.5+2) | 48 | 6.5 | RM |
49 | 49 | S & F (SWR) 110 mm dia bends any radius with rubber ring joints, complete all as specified and directed. (1+1+2) | 49 | 4 | EACH |
50 | 50 | M & L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings ,steps,cills sunshades,shelves, lintel,etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed. (6+5) | 50 | 11 | RM |
51 | 51 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish of the premises complete all as specified and directed. (87+19) | 51 | 106 | SQM |
52 | 52 | M & L joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exe.0.06 sqm but n.exe.0.11 sqm, in floor including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed. (11+14) | 52 | 25 | EACH |
53 | 53 | Refixing of shutter of any description exc. 1 Sqm and n.exc 2 Sqm, in the same opening, complete all as specified and as directed. | 53 | 4 | EACH |
54 | 54 | M & L for glazed ceramic coloured tiles 300x200X 6 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including rendering 10mm thick with cement mortar (1:4) on fair faces of brick work to received tiles in vertical, complete all as specified and directed. | 54 | 21 | SQM |
55 | 55 | S & F 100 mm size butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and as directed. (3+24) | 55 | 27 | EACH |
56 | 56 | S & F 15 mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT' or 'COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed. (2+1) | 56 | 3 | EACH |
57 | 57 | S & F vitreous China squatting pan (Orissa pattern), of size 580x440 mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc., complete all as specified and as directed. | 57 | 1 | EACH |
58 | 58 | S & F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and as directed. | 58 | 2 | EACH |
59 | 59 | S & F (SWR) 75 mm dia bends any radius with rubber ring joints, complete all as specified and directed. (1+2) | 59 | 3 | EACH |
60 | 60 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and as directed. | 60 | 64 | SQM |
61 | 61 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc., or for shafts, well, cess pits, manholes, pier holes etc., n.exc 10Sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil, complete all as specified and as directed. (4+4) | 61 | 8 | CUM |
62 | 62 | Hardcore of broken bricks of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. | 62 | 6.4 | CUM |
63 | 63 | M & L for PCC (1:4:8) type D2 40mm graded stone aggregate as in foundation, sub base, filling and mass concrete etc., complete all as specified. (0.7+0.90+1) | 63 | 2.6 | CUM |
64 | 64 | M & L for 100mm thick PCC (1:4:8) type D2 40mm graded stone aggregate as in sub base of hardstanding, etc., complete all as specified. | 64 | 64 | SQM |
65 | 65 | M & L for 40 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in flooring, hardstanding finishing cement concrete surface even and smooth using extra cement in alternate panels of glass dividing strips, complete all as specified and as directed. Note: Glass dividing strips shall be measured and paid separately. | 65 | 46 | SQM |
66 | 66 | S & F Glass dividing strips, 3 mm thick and width of 38 mm, complete all as specified and as directed. | 66 | 54 | RM |
67 | 67 | Returning, filling in trenches including spreading, levelling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed. (1+6+1) | 67 | 8 | CUM |
68 | 68 | Removing excavated materials exc 250 m and n.exc 500m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed. (12+3) | 68 | 15 | CUM |
69 | 69 | M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4), complete all as specified and as directed. | 69 | 1.8 | CUM |
70 | 70 | M & L for brick work with sub class 'B' bricks straight or curved on plan of any radius in Half brick thick walls built in cement mortar (1:4), complete all as specified and directed. | 70 | 18 | SQM |
71 | 71 | M & L for plastering 10mm thick on fair faces of brickwork or concrete in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed. | 71 | 40 | SQM |
72 | 72 | M & L for sand filling of average thickness not less than 40 mm thick for laying of interlocking paver block etc., complete all as specified and as directed. | 72 | 0.5 | CUM |
73 | 73 | M & L in repairs 60 mm thick, M-35 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, complete all as specified and directed. | 73 | 13 | SQM |
74 | 74 | M & L for plain cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in roof kerbs of mud stops, rounded chamfered on edges, etc., complete all as specified and directed. | 74 | 0.25 | CUM |
75 | 75 | Surface dressing n.exc 15 cm deep and getting out in soft/loose soil, complete all as specified and as directed. | 75 | 12 | SQM |
76 | 76 | Excavating over area, n.exc 1.5m deep and getting out in soft/loose soil, complete all as specified and as directed. | 76 | 15.2 | CUM |
77 | 77 | Excavating over area, exc 1.5m deep but n.exc 3.0 m deep and getting out in soft/loose soil, complete all as specified and as directed. | 77 | 15.2 | CUM |
78 | 78 | Excavating over area, exc 3 m deep but n.exc 4.5 m deep and getting out in soft/loose soil, complete all as specified and as directed. | 78 | 3.6 | CUM |
79 | 79 | M & L for RCC (1:1.5:3) type A-1 using 20mm graded stone aggregate as in foundation, including rafts, footing, foundation beams, plinth beam, bases of columns etc., basement slabs, under reamed piles and mass concrete, complete all as specified and as directed. | 79 | 0.45 | CUM |
80 | 80 | M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in slab supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck clsbs and in shelves and the like, complete all as specified and as directed. | 80 | 1.3 | CUM |
81 | 81 | M & L for brick work with sub class 'B' bricks in one brick thick wall honey comb walling built in cement mortar 1:4, complete all as specified and directed. | 81 | 10 | SQM |
82 | 82 | M & L for brick work with sub class 'B' bricks in one and half brick thick wall honey comb walling built in cement mortar 1:4, complete all as specified and directed. | 82 | 6 | SQM |
83 | 83 | M & L for formwork to soffit of suspended slab such as roof slab, floor slabs, landings and similar work n.exc 200mm thick (horizontal or sloping), complete all as specified and as directed. | 83 | 5.5 | SQM |
84 | 84 | M & L for formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in wall horizontal or sloping or similar work, exc 10cm but n.exc 20 cm, complete all as specified and as directed. (37+168) | 84 | 205 | RM |
85 | 85 | Removing excavated materials n.exc 50 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed. | 85 | 28 | CUM |
86 | 86 | S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed. | 86 | 150 | KG |
87 | 87 | M & L, for Concrete bed to drain pipes including packing under and haunching against the sides of pipes concrete after they are laid in PCC 1:3:6 type C2 using 40mm graded stone aggregate including necessary shuttering and tested for 150mm dia of pipes complete all as specified and as directed . (17+26) | 87 | 43 | RM |
88 | 88 | S & F, PVC (SWR) pipes 150 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and as directed. (17+28) | 88 | 45 | RM |
89 | 89 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm dia pipe, complete all as specified and as directed. (2+1) | 89 | 3 | EACH |
90 | 90 | Loose filling with broken bricks aggregate of gauge 80 to 150 mm in soakage pits, soakage well, complete all as directed. | 90 | 5 | CUM |
91 | 91 | M & L for providing precast cement concrete louvres and jalies, 40 mm thick (measured solid), type B0, (1:2:4), using 12.5 mm graded aggregate) including all mouldings, complete all as specified and as directed. | 91 | 38 | SQM |
92 | 92 | M & L for RCC (1:1.5:3) type A-1 using 20mm graded stone aggregate as beams, coping, etc., and the like including weathering, slightly rounded or chamfered and throating, complete all as specified and as directed. | 92 | 3.8 | CUM |
93 | 93 | M & L for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra or cement), complete all as specified and directed. | 93 | 27 | SQM |
94 | 94 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumer, lintels, coping, cantilevers, shelves including supports, overhangs etc., also splays between floors and beams etc., complete all as specified and as directed. | 94 | 25 | SQM |
95 | 95 | S & F mild steel TMT bars 8mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed. (150+40) | 95 | 190 | KG |
96 | 96 | S & F mild steel TMT bars 5mm dia and over upto 10mm cut to length, bent to shape required including cranking bending with MS wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, complete all as specified. | 96 | 77 | KG |
97 | 97 | S & F precast reinforced cement concrete manhole cover, drain cover in RCC(1:1.5:3) type A1 using 20mm graded stone aggregate set in cement mortar(1:4), complete all as specified. | 97 | 0.5 | CUM |
98 | 98 | M & L for rendering 15mm thick in CM (1:4) finishing surface even and smooth without using extra cement, on brick work or concrete surfaces, complete all as specified and as directed. | 98 | 8 | SQM |
99 | 99 | M & L for 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed | 99 | 2 | SQM |
100 | 100 | M & L for non skid ceramic paver tiles of size 300x300x10 mm thick, coloured as in path etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed. | 100 | 2 | SQM |
101 | 101 | S & F in repairs stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions of bore 20mm complete all as specified and directed and as directed. | 101 | 4 | EACH |
102 | 102 | S & F vitreous China urinal partition white of size 310x700 mm, complete all as specified and as directed. | 102 | 2 | EACH |
103 | 103 | S & F Brass chromium plated towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and as directed. (1+2) | 103 | 1 | EACH |
104 | 104 | M & L for PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joint fixed to walls, complete all as specified and as directed. | 104 | 8 | RM |
105 | 105 | S & F PVC (SWR) 110mm bore junction double (double T), equal or unequal, complete all as specified and as directed. | 105 | 3 | EACH |
106 | 106 | S & F 110mm bore PVC(SWR) vent Cowl, complete all as specified and directed. | 106 | 3 | EACH |
107 | 107 | S & F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebates on the solid, rounded or chamfered put together with glue pinned at joints, complete all as specified and as directed. | 107 | 0.1 | CUM |
108 | 108 | S & F for hold fast, wall ties, hooks for hanging fans, plain angle cleats for securing purlings to wood trusses or rafters, knee piece inserts, two way and threee way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165, complete all as specified and directed. | 108 | 2 | KG |
109 | 109 | M & L for cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in bed blocks, fillings for holdfast etc., complete all as specified and as directed. | 109 | 0.1 | CUM |
110 | 110 | S & F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side either decorative face veneer both face with lipping/frame, complete all as per specified and directed. | 110 | 4 | SQM |
111 | 111 | S & F for small fittings of 2nd class hard wood such as brackets of any type, latch and hinge block shape door, window stops and the like including all necessary labours articles n. exc 200 Cu.cm each, complete all as specified and as directed. | 111 | 2 | EACH |
112 | 112 | S & F mild steel sliding door bolts 250mm long , plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and two on staple plate and fixed complete all as specified and directed by Engr-In-Charge . | 112 | 2 | EACH |
113 | 113 | M & L for preparation of new wooden based surfaces of any description not otherwise described over 10cm width or girth applying two coats synthetic enamel paint (ordinary tint), any colour over a coat of pink primer, complete all as specified and directed by Engr-In-Charge . | 113 | 9 | SQM |
114 | 114 | M & L for non skid coloured ceramic tiles of size 300x300x7 mm thick as in floors etc., over and including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry, and pointed in white or coloured cement to match, complete all as specified and as directed. | 114 | 5 | SQM |
115 | 115 | Taking down carefully any type of point wiring (light, fan, socket bell or power) complete with all fitting such as batten, switch, ceiling rose, pendant, regulator, socket and brackets switch fuse etc removing materials from site and making good disturbed surfaces of walls, floors etc to match the existing surface all as directed . | 115 | 13 | PER POINT |
116 | 116 | M & L for point wiring for one light/ fan point/call bell controlled by one switch with 1100 volt grade PVC insulated FRLS 1.5 Sq mm multi stranded copper conductor cable with continuous PVC FRLS earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed. | 116 | 10 | PER POINT |
117 | 117 | All as per item No 116 here-in-before, but 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete. | 117 | 1 | PER POINT |
118 | 118 | All as per item No 116 above but 1.5 Sq mm for 5 Amp switch socket combination on independent board with 1.5 Sq mm earth wire complete. | 118 | 1 | PER POINT |
119 | 119 | All as per item No 116 above but 2.5 Sq mm for 15 Amp switch socket combination on independent board with 2.5 Sq mm earth wire complete. | 119 | 1 | PER POINT |
120 | 120 | S & F socket outlet 3/5pin, 5 Amp flush type 230 volt, flush type universal, complete all as specified. | 120 | 1 | EACH |
121 | 121 | S & F socket combination 2 in 1, 5 pin 5 Amp flush type universal 230 volt, complete all as specified and as directed. | 121 | 1 | EACH |
122 | 122 | S & F switch socket combination 2 in 1, 6 pin 15 Amp flush type universal 230 volt, complete all as specified and as directed. | 122 | 1 | EACH |
123 | 123 | S & F switch piano type 15 Amp 230 volt one way flush type, universal, complete all as specified and as directed. | 123 | 11 | EACH |
124 | 124 | S & F in repair ceiling rose 3 terminal PVC/ Polycarbonate, isolated body, complete all as specified and as directed. | 124 | 7 | EACH |
125 | 125 | S & F LED tube light along with fixture, 18 Watts, complete all as specified and as directed. | 125 | 4 | EACH |
126 | 126 | S & F fan regulator, electronic type, 5 step, 230 volts, complete all as specified and as directed. | 126 | 3 | EACH |
127 | 127 | S & F angle holder complete all as specified and as directed. | 127 | 3 | EACH |
128 | 128 | S & F LED lamp 9 Watts, complete all as specified and as directed. | 128 | 3 | EACH |
129 | 129 | S & F in repair sheet metal enclosures for DBs single pole & neutral 8 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed. | 129 | 1 | EACH |
130 | 130 | S & F in repair MCB single pole 6 to 16 Amp 240 V, ‘B’ Series, 10 KA, complete all as specified and as directed. | 130 | 4 | EACH |
131 | 131 | S & F in repair MCB DP, 40A, 240V, ‘B’ Series, 10 KA complete all as specified and as directed. | 131 | 1 | EACH |
132 | 132 | S & F isolator 63 Amp FP, 240 V, 'B' Series, 10 kA, complete all as specified and as directed. | 132 | 1 | EACH |
133 | 133 | M & L, for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I, (2009), connected to earth dolly of main DB/main switch all as specified directed including construction of earth chamber with PCC (1:3:6) type C-1 using stone aggregate with pre cast RCC cover slab of size 54 cm x 54 cm x 5 cm thick (1:2:4) type B-1 using 20 mm graded aggregate reinforced with 8 mm dia deformed bars 150 mm spacing both ways and one No. handle with 10 mm dia MS rod for lifting out to required length bent to shape and size as directed, 20mm bore GI watering pipe (medium grade) and earth protected by GI pipe 15 mm bore (light grade) and earth wire mesh funnel charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose any type of soil and dismantling of the existing rusted/deteriorated one complete all as specified and directed. \nNote : Earth test result should not less than one ohm. | 133 | 1 | PER SET |
134 | 134 | M & L for sub main wiring with two single core 6.0 Sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable for earth wire drawn in and including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including taking down of existing conduit or battern, complete and making good disturbed surface wall, complete all as specified and as directed. | 134 | 5 | RM |
135 | 135 | S & F Water Heater Storage type, electric, capacity of 25 litres, BEE 5 Star rated, white colour, rated power 2 KW, complete all as directed. Make: Havells, Cat Part No. GHWAMGTWH025, or its equivalent as per lits of approved make. | 135 | 6 | EACH |
136 | 136 | M & L for point wiring for one socket point controlled by one switch with 1100 volts grade PVC insulated unsheathed 2.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 2.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in and including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia and sunken anodized pressed steel sheet boxes made out of not less than 1.0 mm thick sheet for housing/fixing switches etc, complete all as specified and as directed. | 136 | 6 | PER POINT |
137 | 137 | S & F in repair AC short circuit protection Cat No. DBOXx MCB Protected power unit along with SP 25 Amp. Make: Havells or its equivalent as per approved list. | 137 | 6 | EACH |
138 | 138 | M & L for PVC connections 15 mm size with PTMT nuts of length 300 mm, complete all as specified and as directed. | 138 | 12 | EACH |
139 | 139 | S & F 15mm GI tubes, medium grade, galvanised with all fittings (elbow, nut bolts, sockets etc.,) and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. | 139 | 24 | RM |
140 | 140 | S & F 15 mm stop valves, fancy type, chromium plated, with long shank, and cup headed (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed and as directed. | 140 | 6 | EACH |
141 | 141 | S & F 15mm dia bore bib tap, chromium plated, fancy type, chromium plated cast copper alloy with crutch butterfly handle screwed down, screwed for iron pipe or for brass ferrule etc., complete all as specified and directed. | 141 | 6 | EACH |
142 | 142 | Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, cross sectional area 4 Sq mm, 2 core, 1100 volts grade with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall including testing complete all as specified and directed. | 142 | 585 | RM |
143 | 143 | M & L for cable juction box GFS polycarbonate, weather proof, UV resistant rain water proof, halogen free glow wire test in accordance with IEC 60695-2-II 960 C flame retardant self extinguishing suitable for cable size upto 10 Sq mm IP 66, with terminal, complete all as specified and as directed. | 143 | 42 | EACH |
144 | 144 | M & L for street circuit wiring along with earth wire with the following size of FR PVC insulated copper conductor 2 x 2.5 Sq mm x 1 x 1.5 Sq mm earth wire single multistranded cable in surface/recessed in suitable size of PVC conduit including testing all as specified. | 144 | 80 | RM |
145 | 145 | S & F sheet metal enclosures for DBs single pole & neutral 4 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified and as directed. | 145 | 1 | EACH |
146 | 146 | S & F MCB single pole 6 to 32 Amp 240 V, ‘B’ Series, 10 KA, complete all as specified and as directed. | 146 | 2 | EACH |
147 | 147 | S & F MCB SPN, 20 to 40A 240V, ‘B’ Series, 10 KA complete all as specified and as directed. | 147 | 1 | EACH |
148 | 148 | M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. \nNote : Earth test result should not less than one ohm. | 148 | 1 | EACH |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail