Military Engineer Services-MES has published Special Repairs To Bldg No T-118 , T-217 And T-282 Of Fd Hosp , Provn Of Fuel Injection Eqpt Room Of Fd Wksp Coy ( Eme ) And Provn Of Certain Revenue Works At Along Mil Stn Under Ge 872 Ews ( 8837/E8 ) Special Repairs To Bldg No T-118 , T-217 And T. Submission Date for this Tender is 01-02-2021. Building Repair Tenders in ALONG Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Jan-2021 | CorrigendumNo1 | Date | 25-01-2021 |
2 | 25-Jan-2021 | CorrigendumNo1 | Other | 25-01-2021 |
3 | 25-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-02-2021 |
NAME OF WORK : SPECIAL REPAIRS TO BLDG NO. T-118, T-217 & T-282 OF FD HOSP, PROVN OF FUEL INJECTION EQPT ROOM OF FD WKSP COY (EME) & PROVN OF CERTAIN REVENUE WORKS AT ALONG MIL STN UNDER GE 872 EWS | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | UNITS | |
1 | 1 | B/R SERVICES/WORKS | BI01010001010000000000000515BI0100001113 | ||
2 | 1.001 | Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 1.56 | CUBIC METRE |
3 | 1.002 | Dismantling Timber Scantling 40 Sq Cm and Over in Section in Unframed Work, complete all as specified and as directed. | BI01010001010000000000000515BI0100001115 | 0.16 | CUBIC METRE |
4 | 1.003 | Dismantling Timber Fillets, Rails, Posts, Rafters, Purlins, etc. Under 40 Sq Cm in Section in Unframed Work, complete all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 60 | RUNNING METRE |
5 | 1.004 | Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) not exc. 1.50 Square Metre Each, complete all as specified and as directed. | BI01010001010000000000000515BI0100001117 | 2 | EACH |
6 | 1.005 | Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed. | BI01010001010000000000000515BI0100001118 | 8 | EACH |
7 | 1.006 | Dismantling Plain or Corrugated Steel Sheeting of any gauge and thickness, Segregating the Serviceable Steel Sheeting, stacking properly at Sites and keep in Safe Custody for re-use, complete all as specified and as directed. | BI01010001010000000000000515BI0100001119 | 189 | SQUARE METRE |
8 | 1.007 | Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/ Slabs/ Blankets of any descriptions including Cover Fillets, complete all as specified and as as directed. | BI01010001010000000000000515BI0100001120 | 90 | SQUARE METRE |
9 | 1.008 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. | BI01010001010000000000000515BI0100001121 | 37 | SQUARE METRE |
10 | 1.009 | Hacking out Broken Glass of any description from Wooden or Metal Frames, or Stone, Concrete or Brick surrounds of any thickness or size; Hacking out Old Putty or Removing Beads, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001122 | 4 | SQUARE METRE |
11 | 1.01 | Surface Dressing not exc. 15 Cm Deep and getting out in Soft/Loose soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001123 | 72 | SQUARE METRE |
12 | 1.011 | Surface Excavation not exc. 30 Cm Deep and averaging 15 Cm Deep and getting out in Soft/Loose soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001124 | 12 | SQUARE METRE |
13 | 1.012 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for Foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001125 | 22 | CUBIC METRE |
14 | 1.013 | Returning, Filling in including Spreading, Levelling, Watering and Well Ramming in layers not exc. 25 Cm, in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001126 | 9.9 | CUBIC METRE |
15 | 1.014 | Removing Excavated Materials (Soils) to a distance not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed. | BI01010001010000000000000515BI0100001127 | 22.9 | CUBIC METRE |
16 | 1.015 | Removing Excavated Materials (Soils) to a distance exc. 100.00 Metre but not exc. 250.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed. | BI01010001010000000000000515BI0100001128 | 1.8 | CUBIC METRE |
17 | 1.016 | M&L Sand Filling under Floors or in Foundations including Watering and Consolidation in layers not exc. 150mm thick, complete all as specified and as directed. | BI01010001010000000000000515BI0100001129 | 10.8 | CUBIC METRE |
18 | 1.017 | M&L Sand Gravel (as approved) Filling under Floors or in Foundations including Watering and Consolidation in layers not exc. 15 Cm thick, complete all as specified and as directed. | BI01010001010000000000000515BI0100001130 | 4.5 | CUBIC METRE |
19 | 1.018 | M&L Hardcore broken Stone or Boulders, gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and well rammed to a True surface, complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 14.4 | CUBIC METRE |
20 | 1.019 | M&L Treating the Bottom and Sides of Excavation at the Rate of 5.0 Litre of Emulsion Per Square Metre of Surface Area, complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 34 | SQUARE METRE |
21 | 1.02 | M&L Treating the Top Surface of Filled Earth at the Rate of 5.0 Litre of Emulsion Per Square Metre of Surface Area, complete all as specified and as directed. | BI01010001010000000000000515BI0100001133 | 32 | SQUARE METRE |
22 | 1.021 | M&L Treating the Soil under Plinth Protection at the Rate of 5.0 Litre of Emulsion Per Square Metre of Surface Area, complete all as specified and as directed. | BI01010001010000000000000515BI0100001134 | 11 | SQUARE METRE |
23 | 1.022 | M&L Treating at Points of Contact of Wood Work by Chemical Emulsion (in Oil or Kerosene based Solution) @ 0.5 Litre Per Hole by drilling 6.0mm dia Holes at a downward Angle of 45° at 150mm Centre to Centre and Sealing the same, complete all as specified and as directed. | BI01010001010000000000000515BI0100001135 | 31.2 | RUNNING METRE |
24 | 1.023 | M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including necessary Formwork as ordered, complete all as specified and as directed. | BI01010001010000000000000515BI0100001136 | 2 | CUBIC METRE |
25 | 1.024 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 60 Cm in heights, Coping, Kneelers, Apex Stone Bed Plate, Kerbs, Water Trough, etc., weathering, slightly champhered angles and throating including Use and Waste of Formwork, complete all as specified and as directed. | BI01010001010000000000000515BI0100001137 | 1.96 | CUBIC METRE |
26 | 1.025 | M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Roof Beams, Lintel Bands, Cantilevers, Bressumers, Lintels over 1.50 Metre Span, etc., complete all as specified and as directed.\nNOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items. | BI01010001010000000000000515BI0100001138 | 0.2 | CUBIC METRE |
27 | 1.026 | M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Chajja, etc., complete all as specified and as directed.\nNOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items. | BI01010001010000000000000515BI0100001139 | 0.2 | CUBIC METRE |
28 | 1.027 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Girders, Beam Haunchings, Bress-summers, Lintels, Cantilevers, Shelves including Supports, Overhangs, etc. also splays between Floors and Beams, etc, Rough Finished Surfaces of Concrete Flat, complete all as specified and as directed. | BI01010001010000000000000515BI0100001140 | 2.5 | SQUARE METRE |
29 | 1.028 | M&L Formwork to Chullah Hoods, Chajjas, Trough and and Similar Items including Edges (Horizontal or Sloping) Rough Finished Surface of Concrete Flat, complete all as specified and as directed. | BI01010001010000000000000515BI0100001141 | 1.6 | SQUARE METRE |
30 | 1.029 | M&L Formwork to Edges of Concrete Flats, Treads, Breaks in Floors, Window Cills, Concrete Railings, Openings in Concrete Walls, Floor and Roofs not exc. 20 Cm Wide and Sides of RCC/ PCC Bands in Walls, Horizontal or Sloping and Similar Work, exc. 10 Cm but not exc. 20 Cm Wide, Rough Finished Surface of Concrete Flat, complete all as specified and as directed. | BI01010001010000000000000515BI0100001142 | 5.5 | RUNNING METRE |
31 | 1.03 | M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks in Cement Concrete 1:3:6 (20mm graded stone aggregate), exc. 10 Cm in Width and setting in Cement Mortar 1:6, complete all as specified and as directed. | BI01010001010000000000000515BI0100001143 | 24.58 | CUBIC METRE |
32 | 1.031 | M&L Cement Concrete 1:2:4 (12.5mm graded stone aggregate) 40mm thick in Damp Proof Courses to Horizontal or Vertical Surfaces including Use & Waste of Formwork and Applying evenly a coat of Blown type Bitumen @ 1.50 KG/SQM and blinding with Clean Dry Sand @ 0.05 CUM/SQM, complete all as specified and as directed. | BI01010001010000000000000515BI0100001144 | 4 | SQUARE METRE |
33 | 1.032 | M&L Second Class Hardwood (well seasoned) Plain Fillets, Cleanswan, Square, Rectangular or Triangular in Section, exc. 13 Sq Cm but not exc, 25 Sq Cm (50x50mm as Studs), fixed with Nails, complete all as specified and as directed. | BI01010001010000000000000515BI0100001145 | 50 | RUNNING METRE |
34 | 1.033 | M&L Second Class Hardwood (well seasoned), Plain Fillets, Cleanswan, Square, Rectangular or Triangular in Section, exc. 6.0 Sq Cm but not exc, 13 Sq Cm (25x25mm as Forking Piece), fixed with Screws, complete all as specified and as directed. | BI01010001010000000000000515BI0100001146 | 10 | RUNNING METRE |
35 | 1.034 | M&L Second Class Hardwood (well seasoned), Plain Fillets, Wrought, Square in Section, exc. 3.0 Sq Cm but not exc, 6.0 Sq Cm (Cover Fillets 40x12mm in Section), fixed with Nails, complete all as specified and as directed. | BI01010001010000000000000515BI0100001147 | 120 | RUNNING METRE |
36 | 1.035 | M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed. | BI01010001010000000000000515BI0100001148 | 0.23 | CUBIC METRE |
37 | 1.036 | M&L Second Class Hardwood (well seasoned) Panelled Shutter 35mm thick (any number Panels) Plain, Framed with Lock Rails, having Panels of 12mm thick Veneered Particle Board medium density, Wood Particle Board with Commercial Face Veneers and fitted to Chowkat, complete all as specified and as directed. | BI01010001010000000000000515BI0100001149 | 10.53 | SQUARE METRE |
38 | 1.037 | M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, Divided into Squares, with plain, chamfered or rounded, mitred and rebated Sash Bars to receive Gauge/Glass, any numbers, sizes of Members of Shutter as specified in SSR Part-I, Section 8, Clause 8.24(b) and fitted to Chowkat, complete all as specified and as directed. | BI01010001010000000000000515BI0100001150 | 10.53 | SQUARE METRE |
39 | 1.038 | M&L Second Class Hardwood (well seasoned) Small Fittings such as Brackets of any type, Latch and Hinge Blocks, Shaped Door and Window Stops and the like, including all necessary Labours; Articles not exc. 200 Cu Cm Each, complete all as specified and as directed.\nNOTE : Butt Hinge will be Measured and Paid under appropriate Item as 'supply only'. | BI01010001010000000000000515BI0100001151 | 6 | EACH |
40 | 1.039 | M&L Anodised Aluminium Powder Coated (Thickness of Powder Coating not less than 50 micron) Frame for Doors, Windows, Ventilators with One or More Rebates including Joining Cleat for fixing, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001152 | 16 | KILO-GRAM |
41 | 1.04 | M&L Anodised Aluminium Powder Coated (Thickness of Powder Coating not less than 50 micron) Door Shutters, Aluminium Section weighing not less than 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber/ Neoprene Packing, Handles (as approved) - 2 No. in Each Door, Stainless Steel Hinges of size as ordered, anodised Aluminium Snap Beading, Screws, etc, complete all as specified and as directed. | BI01010001010000000000000515BI0100001153 | 5.84 | SQUARE METRE |
42 | 1.041 | M&L Anodised Aluminium Powder Coated (Thickness of Powder Coating not less than 50 micron) Window and Ventilator Shutters, fixed type without Sash Bar, Aluminium Section weighing 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber/ Neoprene Packing, anodised Aluminium Snap Beading, Screws, etc, complete all as specified and as directed. | BI01010001010000000000000515BI0100001154 | 8.28 | SQUARE METRE |
43 | 1.042 | S&F Aluminium anodised Barrel Tower Bolt 150mm long (as approved), Extruded Section, complete all as specified and as directed. | BI01010001010000000000000515BI0100001155 | 6 | EACH |
44 | 1.043 | S&F Aluminium anodised Barrel Tower Bolt 200mm long (as approved), Extruded Section, complete all as specified and as directed. | BI01010001010000000000000515BI0100001156 | 12 | EACH |
45 | 1.044 | S&F Aluminium alloy, anodised, Sliding Door Bolt 300mm long with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed. | BI01010001010000000000000515BI0100001157 | 6 | EACH |
46 | 1.045 | Supply only Stainless Steel Butt Hinge 50mm in size (as approved), complete all as specified and as directed. | BI01010001010000000000000515BI0100001158 | 2 | EACH |
47 | 1.046 | S&F Stainless Steel Butt Hinge 75mm in size (as approved), complete all as specified and as directed. | BI01010001010000000000000515BI0100001159 | 12 | EACH |
48 | 1.047 | S&F Stainless Steel Butt Hinge 100mm in size (as approved), complete all as specified and as directed. | BI01010001010000000000000515BI0100001160 | 24 | EACH |
49 | 1.048 | S&F Aluminium Handle 125mm (as approved), Cast type, anodised, complete all as specified and as directed. | BI01010001010000000000000515BI0100001161 | 12 | EACH |
50 | 1.049 | S&F Aluminium Handle 150mm (as approved), Cast type, anodised, complete all as specified and as directed. | BI01010001010000000000000515BI0100001162 | 12 | EACH |
51 | 1.05 | S&F Mild Steel Ordinary Rat Tail 300mm, Rod pattern Springs including Roller and Roller Plate, complete all as specified and as directed. | BI01010001010000000000000515BI0100001163 | 6 | EACH |
52 | 1.051 | S&F Brass Mortice Lock, Vertical type of size 100mm, 4 Levers, complete all as specified and as directed. | BI01010001010000000000000515BI0100001164 | 3 | EACH |
53 | 1.052 | S&F Floor Door Stopper (as approved) having Overall Length of Cover Plate 150mm of Aluminium Alloy Body and Tongue, anodised, with Hard Drawn Steel Spring, fixed in Floor, complete all as specified and as directed. | BI01010001010000000000000515BI0100001165 | 9 | EACH |
54 | 1.053 | S&F Door Closer Aluminium alloy (Extruded Section) Body, Hydraulically Regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in Width and of Weight between 61.00 to 80.00 KG, complete all as specified and as directed. | BI01010001010000000000000515BI0100001166 | 3 | EACH |
55 | 1.054 | S&F Decorative Curtain Rod 20mm Outer dia of Mild Steel Conduit including Decorative Side Dooms, Brackets, Stops, etc. as required to hold the Curtain Rod and having minimum 8 No. Curtain Rings in Per RM of Length, complete all as specified and as directed. | BI01010001010000000000000515BI0100001167 | 10 | RUNNING METRE |
56 | 1.055 | M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed. | BI01010001010000000000000515BI0100001168 | 5.04 | SQUARE METRE |
57 | 1.056 | M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples and Fixed-in-repairs, complete all as specified and as directed. | BI01010001010000000000000515BI0100001169 | 9.9 | SQUARE METRE |
58 | 1.057 | S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed. | BI01010001010000000000000515BI0100001170 | 6 | SQUARE METRE |
59 | 1.058 | S&F Sheet Glass 5.5mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed. | BI01010001010000000000000515BI0100001171 | 7.57 | SQUARE METRE |
60 | 1.059 | S&F Solar Control Film 25 Micron Reflective Type Sticked to Glass Panes of any size and thickness as per Instructions of Manufacturers, complete all as specified and as directed. | BI01010001010000000000000515BI0100001172 | 7.19 | SQUARE METRE |
61 | 1.06 | S&F PVC White Vertical Venetian Blind (as approved) and fixing on Window with nessary Fixing Arrangements as per Instructions of Manufacturers, complete all as specified and as directed. | BI01010001010000000000000515BI0100001173 | 1.44 | SQUARE METRE |
62 | 1.061 | M&L TMT Bars 10mm dia and Over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. | BI01010001010000000000000515BI0100001174 | 19 | KILO-GRAM |
63 | 1.062 | M&L TMT Bars 8.0mm dia in Stirrups, Spacers and Binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. | BI01010001010000000000000515BI0100001175 | 16 | KILO-GRAM |
64 | 1.063 | M&L Rolled Mild Steel in Plate Girder or Single Stanchions, built up of One Beam or Channel Section with Flange Plates, Caps, Bases. Splices, Angle Brackets, Cleats and Other Connections, conforming to Gde Fe-410-W (Gde E-250) Quality 'B', complete all as specified and as directed. | BI01010001010000000000000515BI0100001176 | 300 | KILO-GRAM |
65 | 1.064 | M&L Mild Steel Work (Square/ Rectangular Hollow Section) in Tublar Trusses including Special Shaped Washers, etc. complete using ERW or Induction Butt welded Tubes, confirming to IS:1161-1979, Grade St-240, complete all as specified and as directed. | BI01010001010000000000000515BI0100001177 | 550 | KILO-GRAM |
66 | 1.065 | M&L Mild Steel Framed Work such as Grills, Gratings, etc, with Ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walkways, Railings, Frame Work of Water Tanks and Similar Works, conforming to Fe-290, Gde E-165, complete all as specified and as directed. | BI01010001010000000000000515BI0100001178 | 138.6 | KILO-GRAM |
67 | 1.066 | M&L Mild Steel Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes including Bolts, Hooks (Stay) for large Gates; Hook and Pintle Hinges: large Hasps and Staples; Hand Made Sliding Bolts; Clamps; Holdfasts; Wall Ties and similar small Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed. | BI01010001010000000000000515BI0100001179 | 7.6 | KILO-GRAM |
68 | 1.067 | S&F Corrugated Mild Steel Sheeting 0.63mm thick Galvanised @ 275 Gram Per Sqm, with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001180 | 30 | SQUARE METRE |
69 | 1.068 | M&L Refixing Corrugated or Plain Mild Steel Sheeting 0.63mm thick (Serviceable Steel Sheets obtained from Item No. 1.006 here-in-before) with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001181 | 50 | SQUARE METRE |
70 | 1.069 | S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed. | BI01010001010000000000000515BI0100001182 | 153 | SQUARE METRE |
71 | 1.07 | S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/ Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed. | BI01010001010000000000000515BI0100001183 | 11.1 | SQUARE METRE |
72 | 1.071 | S&F Aluminium Snap Grid Frame Work of size 605x605mm in False Ceiling as per Specifications and shown in Drawings with and including Hangers 4.0mm dia GI (upto 1500mm in Length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed., complete all as specified and as directed. | BI01010001010000000000000515BI0100001184 | 79.76 | SQUARE METRE |
73 | 1.072 | S&F Prelaminated Particle Board/ Tiles 9.0mm thick and 60x60 Cm in size, Interior grade, Prelaminated One Side with Decorative Choice Lamination and Other Side Balancing White Lamination, inserted on Snap Grid Frame Work and fixing with Clips or Staples/Screws, complete all as specified and as directed. | BI01010001010000000000000515BI0100001185 | 25.76 | SQUARE METRE |
74 | 1.073 | S&F Perforated Particle Board/ Tiles 12mm thick and 60x60 Cm in size for Insulation and Accoustic purposes, inserted on Snap Grid Frame Work and fixing with Clips or Staples/Screws, complete all as specified and as directed. | BI01010001010000000000000515BI0100001186 | 54 | SQUARE METRE |
75 | 1.074 | S&F HSPC Non-Asbestos Fibre Cement Building Boards 4.0mm thick, fixed to Timber Frame Work with Screws, complete all as specified and as directed. | BI01010001010000000000000515BI0100001187 | 90 | SQUARE METRE |
76 | 1.075 | M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) 75mm thick in Sub-base to Flooring, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001188 | 30 | SQUARE METRE |
77 | 1.076 | M&L Cement Concrete 1:2:4 (12.5mm graded stone aggregate) 25mm thick as Sub-base/ Base Course for laying of Tiles, etc., finished Concrete Surfaces Fair and Even, complete all as specified and as directed. | BI01010001010000000000000515BI0100001189 | 30 | SQUARE METRE |
78 | 1.077 | M&L Roughening Surfaces of Old Concrete Floor by Picking, Sweeping Clean and Washing down with Water to remove Dust, etc., and Brushing with Neat Cement Slurry @ 3.0 KG/SQM on Cleaned Concrete Surfaces, complete all as specified and as directed. | BI01010001010000000000000515BI0100001190 | 148.5 | SQUARE METRE |
79 | 1.078 | M&L Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Square/ Rectan- gular), Area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm (1st quality) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate | BI01010001010000000000000515BI0100001191 | 135 | SQUARE METRE |
80 | 1.079 | M&L Vitrified Ceramic Light Shade Tiles 10mm thick (Square/ Rectangular), Polished, Area of Each Tile not exc. 0.36 Sqm (1st quality) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate. | BI01010001010000000000000515BI0100001192 | 30 | SQUARE METRE |
81 | 1.08 | M&L Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Square/Rectan-gular), Area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm (1st quality) in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate. | BI01010001010000000000000515BI0100001193 | 13.5 | SQUARE METRE |
82 | 1.081 | M&L Vitrified Ceramic Light Shade Tiles 10mm thick (Square/ Rectangular), Polished, Area of Each Tile not exc. 0.36 Sqm (1st quality) in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate | BI01010001010000000000000515BI0100001194 | 1.94 | SQUARE METRE |
83 | 1.082 | M&L Glazed Ceramic Coloured Tiles 300x200x6.0mm-7.0mm thick (1st quality) in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate. | BI01010001010000000000000515BI0100001195 | 37 | SQUARE METRE |
84 | 1.083 | M&L Cement Concrete 1:3:6 (20mm graded stone aggregate) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed. | BI01010001010000000000000515BI0100001196 | 11 | SQUARE METRE |
85 | 1.084 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 50mm thick in Sub-base, finished Concrete Surfaces Fair and Even, complete all as specified and as directed. | BI01010001010000000000000515BI0100001197 | 72 | SQUARE METRE |
86 | 1.085 | M&L Chequered Cement Concrete Tiles 200x200x22mm to 25mm thick with Grey Cement and Pigments, Set, Jointed and Pointed in Neat Cement Slurry in Floors. laid over and including Screed or Screed Bed 20mm thick in Cement Mortar 1:6, complete all as specified and as directed.\nNOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate | BI01010001010000000000000515BI0100001198 | 72 | SQUARE METRE |
87 | 1.086 | M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Sub-base to Hardstanding, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001199 | 12 | SQUARE METRE |
88 | 1.087 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 50mm thick in Hardstanding, etc., finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. | BI01010001010000000000000515BI0100001200 | 12 | SQUARE METRE |
89 | 1.088 | M&L Forming Contraction (Dummy Joint) 25mm Deep x 10mm Wide and filled with Sealing Compound Grade 'A', complete all as specified and as directed. | BI01010001010000000000000515BI0100001201 | 1.4 | TEN RUNNING METRE |
90 | 1.089 | M&L Rendering 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. | BI01010001010000000000000515BI0100001202 | 70 | SQUARE METRE |
91 | 1.09 | M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. | BI01010001010000000000000515BI0100001203 | 1.5 | SQUARE METRE |
92 | 1.091 | M&L Rendering 15mm thick on Brick/PCC Blocks, consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:6 and Float/ Top layer 5.0mm thick in Cement Mortar 1:4 including mixeing WPC to Float/ Top layer, finished Fair and Even, complete all as specified and as directed. \nNOTE : Water Proofing Compound (WPC) will be Measured and Paid saperately under appropriate Item. | BI01010001010000000000000515BI0100001204 | 77 | SQUARE METRE |
93 | 1.092 | Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed. | BI01010001010000000000000515BI0100001205 | 3.87 | KILO-GRAM |
94 | 1.093 | M&L Preparing New Plastered Surfaces on Concrete Work of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. | BI01010001010000000000000515BI0100001206 | 1.5 | SQUARE METRE |
95 | 1.094 | M&L Preparing New Non-Asbestos Fibre Cement Building Boards Surfaces on Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. | BI01010001010000000000000515BI0100001207 | 90 | SQUARE METRE |
96 | 1.095 | M&L Preparing Old Treated Surfaces of any description on Ceiling and applying One Coat of White Wash, complete all as specified and as directed. | BI01010001010000000000000515BI0100001208 | 90 | SQUARE METRE |
97 | 1.096 | M&L Applying a Layer of Wall Care Putty 3.0mm thick on Plastered Surfaces of Walls including Cutting and Rubbing down to obtain a Even and Smooth Surface, complete all as specified and as directed. | BI01010001010000000000000515BI0100001209 | 60 | SQUARE METRE |
98 | 1.097 | M&L Preparing New Plastered Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion (as approved Tint) over a Coat of Chalk Whitening (Priming Coat), complete all as specified and as directed. | BI01010001010000000000000515BI0100001210 | 70 | SQUARE METRE |
99 | 1.098 | M&L Preparing Old Treated Plastered Surfaces of Walls by Complete Removal of existing Surface Treatment and applying Two Coats of Distemper Oil Emulsion (as approved Tint) over a Coat of Chalk Whitening (Priming Coat), complete all as specified and as directed. | BI01010001010000000000000515BI0100001211 | 160 | SQUARE METRE |
100 | 1.099 | M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint (as approved Tint) over a coat of Alkali Resistant Priming Paint, complete all as specified and as directed. | BI01010001010000000000000515BI0100001212 | 77 | SQUARE METRE |
101 | 1.1 | M&L Preparing Old Treated Plastered Surfaces of Walls by Complete Removal of existing Surface Treatment and applying Two Coats of Cement Based Paint (as approved Tint) over a coat of Alkali Resistant Priming Paint, complete all as specified and as directed. | BI01010001010000000000000515BI0100001213 | 35 | SQUARE METRE |
102 | 1.101 | M&L Preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Pink Primer, complete all as specified and as directed. | BI01010001010000000000000515BI0100001214 | 39 | SQUARE METRE |
103 | 1.102 | M&L Preparing Old Painted Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying One Coat of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint), complete all as specified and as directed. | BI01010001010000000000000515BI0100001215 | 150 | SQUARE METRE |
104 | 1.103 | M&L Preparing New Wooden Surfaces of any description, not exc. 10 Cm in Width or Girth when unconnected with other Painting or when Painted in different Tint and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Pink Primer, complete all as specified and as directed. | BI01010001010000000000000515BI0100001216 | 12 | TEN RUNNING METRE |
105 | 1.104 | M&L Preparing Steel and Iron Surfaces of any descriptions, over exc. 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed. | BI01010001010000000000000515BI0100001217 | 20.48 | SQUARE METRE |
106 | 1.105 | M&L Preparing Old Treated Steel and Iron Surfaces of any descriptions, over exc. 10 Cm in Width or Girth and applying One Coat of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint), complete all as specified and as directed. | BI01010001010000000000000515BI0100001218 | 110 | SQUARE METRE |
107 | 1.106 | M&L Preparing New Steel and Iron Surfaces of any description, not exc. 10 Cm in Width or Girth when unconnected with other Painting or when Painted in different Tint and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed. | BI01010001010000000000000515BI0100001219 | 10 | TEN RUNNING METRE |
108 | 1.107 | M&L Preparing New or Previously Treated Surface of Wood and Wood based Materials of any description and girth and treated with Two Coats of Creosote Oil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001220 | 10 | SQUARE METRE |
109 | 1.108 | M&L Preparing previously Untreated Surfaces of Wood and Wood Based Materials, of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Backs of Chowkats, etc. Area tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed. | BI01010001010000000000000515BI0100001221 | 0.06 | HUNDRED NUMBER |
110 | 1.109 | M&L Preparing previously Untreated Surfaces of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Holdfast or similar Small Items, Area tarred not exc. 0.10 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed. | BI01010001010000000000000515BI0100001222 | 0.3 | HUNDRED NUMBER |
111 | 2 | E/M SERVICES/WORKS | BI01010001010000000000000515BI0100001223 | ||
112 | 2.001 | M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc., Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 and Providing Surface Treatment (White washing, Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed. | BI01010001010000000000000515BI0100001224 | 105 | PER POINT |
113 | 2.002 | M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 and Providing Surface Treatment (White washing, Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed. | BI01010001010000000000000515BI0100001225 | 50 | RUNNING METRE |
114 | 2.003 | M&L Taking down/out Unserviceable MCB, Isolator, etc. of any description from in any Position, complete all as specified and as directed. | BI01010001010000000000000515BI0100001226 | 25 | EACH |
115 | 2.004 | M&L Taking down/out Unserviceable Distribution Board of any description from in any Position including Making Good disturbed Surfaces of Walls, etc. in Cement Mortar 1:3 and Providing Surface Treatment (White washing, Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed. | BI01010001010000000000000515BI0100001227 | 3 | EACH |
116 | 2.005 | M&L Taking down/out Unserviceable Earthing of any description from in any Position including Making Good disturbed Surfaces of Walls, etc. (if any) in Cement Mortar 1:3 and Providing Surface Treatment (White washing, Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed. | BI01010001010000000000000515BI0100001228 | 3 | EACH SET |
117 | 2.006 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed. | BI01010001010000000000000515BI0100001229 | 78 | PER POINT |
118 | 2.007 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed. | BI01010001010000000000000515BI0100001230 | 13 | PER POINT |
119 | 2.008 | &L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed. | BI01010001010000000000000515BI0100001231 | 20 | PER POINT |
120 | 2.009 | &L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed. | BI01010001010000000000000515BI0100001232 | 7 | PER POINT |
121 | 2.01 | M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 16 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed. | BI01010001010000000000000515BI0100001233 | 6 | PER POINT |
122 | 2.011 | M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed.\nNOTE :-\n(a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be include in the Quoted Unit Rate and the same will be Mesured as ONE UNIT.\n(b) Sub-main Wiring will be measured PVC Casing Capping only. Wires required for looping, etc. as ordered will deem to be include in the Quoted UNIT RATE. | BI01010001010000000000000515BI0100001234 | 40 | RUNNING METRE |
123 | 2.012 | M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed.\nNOTE :-\n(a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be include in the Quoted Unit Rate and the same will be Mesured as ONE UNIT.\n(b) Sub-main Wiring will be measured PVC Casing Capping only. Wires required for looping, etc. as ordered will deem to be include in the Quoted UNIT RATE. | BI01010001010000000000000515BI0100001235 | 35 | RUNNING METRE |
124 | 2.013 | S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed | BI01010001010000000000000515BI0100001236 | 20 | RUNNING METRE |
125 | 2.014 | S&F Rigid Non-metallic PVC Conduit 25mm Outer dia (ISI Marked) exclusive of Boxes (Junction/ Terminal) but inclusive all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends, Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001237 | 40 | RUNNING METRE |
126 | 2.015 | S&F Rigid Non-metallic PVC Concealed Conduit 25mm Outer dia (ISI Marked) inclusive of all Junction Boxes, Bends, Tees, Elbows, Reducers, Bell Mouth Tube Ends, etc. with all Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001238 | 20 | RUNNING METRE |
127 | 2.016 | S&F PVC Rectangular Block of size 350x300x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block (if ordered), complete all as specified and as directed. | BI01010001010000000000000515BI0100001239 | 2 | EACH |
128 | 2.017 | S&F Switch Piano 6 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001240 | 111 | EACH |
129 | 2.018 | S&F Switch Piano 16 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001241 | 2 | EACH |
130 | 2.019 | S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001242 | 2 | EACH |
131 | 2.02 | S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001243 | 31 | EACH |
132 | 2.021 | S&F Socket Outlet 16 Amp, 3 Pin, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001244 | 1 | EACH |
133 | 2.022 | S&F Switch Socket Combination 6 Amp, 3/5 Pin & 16 Amp 3/5 Pin, Flush type, Multi-plug, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001245 | 11 | EACH |
134 | 2.023 | S&F Switch Socket Combination 6/16 Amp, 2-in-1 (3 Pin & 3 Pin), multi-purpose, 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001246 | 1 | EACH |
135 | 2.024 | S&F Lamp/ Batten/ Angle Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001247 | 8 | EACH |
136 | 2.025 | S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001248 | 124 | EACH |
137 | 2.026 | S&F LED Tube Light Fitting 1x20 Watt, Aluminum Extrution Housing with Light Source 20 Watt, having Integrated Electronic Driver, Pre-wired, connecting up with and including suitable Length and size Twisted Flexible Copper Conductor Cable, 3 Core, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS (as approved by GE). | BI01010001010000000000000515BI0100001249 | 6 | EACH |
138 | 2.027 | S&F LED Tube Light Fitting 1x20 Watt with LED Tube 20 Watt, Pre-wired, fixing on and including 2 No. PVC Box, connecting up with and including suitable Length and size Twisted Flexible Copper Conductor Cable, 3 Core, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. UMILINEBS20WLED840SPCWH or equivalent Model/ Cat No. in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE). | BI01010001010000000000000515BI0100001250 | 34 | EACH |
139 | 2.028 | S&F LED Tube Light Fitting 1x20 Watt with LED Light source 20 Watt, Attractive, Wall/ Ceiling mounted type, Polycarbonate Body and White Reflector suitable for Mirror Fitting with Electronic Driver, Connector Blocks, etc., connecting up with and including suitable Length and size Twisted Flexible Copper Conductor Cable, 3 Core, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS (as approved by GE). | BI01010001010000000000000515BI0100001251 | 6 | EACH |
140 | 2.029 | S&F Panel Square 2'x2' LED Light Fitting 30 Watt of size 595x595x70mm with high brightness SMD LEDs as Light Source with Driver 28 Watt, Environmental Friendly, New generation, Aesthetically designed, Ultra modern, Recess mount-ing suitable for Ceiling mounted, complete with all Accessories, Pre-wired, connecting up with and including suitable Length and size Twisted Flexible Copper Conductor Cable, 3 Core, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS (as approved by GE). | BI01010001010000000000000515BI0100001252 | 6 | EACH |
141 | 2.03 | M&L Taking down Ceiling Fan, Exhaust Fan, etc. of any Make, Size after disconnecting and Keep in Safe Custody for Re-hanging/ Re-fixing after Repaired, complete all as specified and as directed. | BI01010001010000000000000515BI0100001253 | 13 | EACH |
142 | 2.031 | M&L Lowering down Ceiling Fan 1200mm Sweep after disconnecting, Transpor -ting from Site of Work to nearest Workshop, Taking out burnt Winding by opening Casing of the Fan, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (not less than 350 Gram) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. | BI01010001010000000000000515BI0100001254 | 2 | EACH JOB |
143 | 2.032 | M&L Preparing Old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamel Paint (as approved) with Spray Painting Machine and Stencil Writing MES No. (not exc. 30mm in Height) with Black Paint, complete all as specified and as directed. | BI01010001010000000000000515BI0100001255 | 13 | EACH JOB |
144 | 2.033 | M&L Mild Steel Flat Iron 40x3mm as Fan Hook, cut to length, bent to Shape, drilling holes as required, etc. for hold GI Pipe hanging Fan, conforming to Fe-290 Gde-E-165 including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as as directed. | BI01010001010000000000000515BI0100001256 | 8 | EACH JOB |
145 | 2.034 | Supply & Hanging Ceiling Fan 1200mm Sweep, 75 Watt, 50 Hz, 220/230 Volt AC, Double Ball Bearing system and High Speed Performance, long lasting Paint Finish, connecting with and including suitable size Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed. | BI01010001010000000000000515BI0100001257 | 4 | EACH |
146 | 2.035 | M&L Hanging/Fixing only Ceiling Fan, Exhaust Fan (Serviceable Celiling Fan obtained from Item No. 2.030 here-in-before after necessary repairing) and connecting with and including suitable size Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed. | BI01010001010000000000000515BI0100001258 | 13 | EACH |
147 | 2.036 | S&F Ceiling Fan Regulator, Dimmer Switch type, 230 Volt AC, Rotary Stepped Electronic, 120/280 Volt including necessary Connection and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001259 | 17 | EACH |
148 | 2.037 | Supply & Installation Hi Wall Split Unit Air Conditioner 1.5 TR complete with Indoor & Outdoor Unit with Cordless remote Control Unit and Inbuilt Air Ionizer and Plasma Filter for better Indoor Air quality with 5 Star rating and EER 3.2/4.7 suitable for operation on 230 Volt AC, 50 Hz, Single Phase and Electrically connecting up, complete all as specified and as directed.\nMAKE : CARRIER/ DAIKIN/ HITACHI/ LG (as approved by GE) | BI01010001010000000000000515BI0100001260 | 1 | EACH |
149 | 2.038 | S&F Copper Tubing, Pair of 2 Pipes for Suction & Discharge, Suction Pipe ½” dia and Discharge Pipe ¼” dia, both are 0.8mm Wall thickness with Complete Separate Insulation 9.0mm thick including cutting chasess on Walls and Making Good Distrubed Surfaces in Cement Mortar 1:3 and Surfaces Treatment to match the existing Surfaces/ Adjoining area, complete all as specified and as directed. | BI01010001010000000000000515BI0100001261 | 6 | RUNNING METRE |
150 | 2.039 | Supply & Installation Voltage Stabiliser 3.0 KVA for Automatic Operation, Single Phase, Naturally Air Cooled Indoor type and designed for Input variation between 170 Volt to 250 Volt with Output Voltage stabilized at 230 Volt with accuracy of ± 2.5% and Electrically connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001262 | 1 | EACH |
151 | 2.04 | S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 20 Amp, 240 Volt and connecting up, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. DHDPUSN020/DHDPUDPO20 or equivalent Model in Make : LEGRAND/ L&T/ SCHNEIDER (as approved by GE) | BI01010001010000000000000515BI0100001263 | 1 | EACH |
152 | 2.041 | S&F MCB Single Pole 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001264 | 28 | EACH |
153 | 2.042 | S&F MCB Single Pole & Neutral 40 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up, complete all as specified and as directed. | BI01010001010000000000000515BI0100001265 | 3 | EACH |
154 | 2.043 | S&F MCB Isolator, Double Pole 63 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB Isolator, complete all as specified and as directed. | BI01010001010000000000000515BI0100001266 | 1 | EACH |
155 | 2.044 | S&F MCB Distribution Board Sheet Metal Enclosure SPN, 8-way, 240 Volt, Single Door with Steel Phosphotised Powder painted, with 200 Amp rated Neutral Bars & Earth Bar and connecting up, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. DHDPSHOSRW08 or equivalent Model/ Cat No. in Make : LEGRAND/ L&T/ SCHNEIDER (as approved by GE) | BI01010001010000000000000515BI0100001267 | 3 | EACH |
156 | 2.045 | S&F MCB Distribution Board Sheet Metal Enclosure SPN, 12-way, 240 Volt, Double Door with Steel Phosphotised Powder painted, with 200 Amp rated Neutral Bars & Earth Bar and connecting up, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. DHDPSHOSRW12 or equivalent Model/ Cat No. in Make : LEGRAND/ L&T/ SCHNEIDER (as approved by GE) | BI01010001010000000000000515BI0100001268 | 1 | EACH |
157 | 2.046 | Supply & Laying or Passing through Pipe 1100 Volt grade heavy duty, Cross-sectional area 10 Sqmm, 2 Core, Flat or Circular Cable with PVC insulated Aluminium Conductor served with an inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed in Service Connection suspended by insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire including Taking down unserviceable Service Connection Wires, complete all as specified and as directed. | BI01010001010000000000000515BI0100001269 | 20 | RUNNING METRE |
158 | 2.047 | Supply & Laying or Passing through Pipe 1100 Volt grade heavy duty, Cross-sectional area 16 Sqmm, 2 Core, Flat or Circular Cable with PVC insulated Aluminium Conductor served with an inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed in Service Connection suspended by insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed. | BI01010001010000000000000515BI0100001270 | 42 | RUNNING METRE |
159 | 2.048 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing, complete all as specified and as directed. | BI01010001010000000000000515BI0100001271 | 4 | EACH SET |
160 | 2.049 | Excavating in Trenches, not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Taking out/ up and/or laying of Water Pipe Line, Cable Line, etc., Forming Surfaces to required Foundation/ Gradient and getting out as in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001272 | 12.5 | CUBIC METRE |
161 | 2.05 | Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps with Surplus Soil along the Route of the Water Pipe Line, Cable Line, etc., in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001273 | 12.5 | CUBIC METRE |
162 | 2.051 | Supply & Laying LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998, Cross-sectional Area 6.0 Sqmm, 2 Core, laid in Trenches, Ducts, Pipes or on Poles, etc, complete all as specified and as directed\nNOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001274 | 40 | RUNNING METRE |
163 | 2.052 | Supply & Laying LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998, Cross-sectional Area 10 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc, complete all as specified and as directed\nNOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001275 | 60 | RUNNING METRE |
164 | 2.053 | Supply & Laying HDPE Double Wall Corrugated (DWC) High Density Polythene Pipes of Outer Dia 40mm & Inner Dia 32mm, having corrugation on the Outer Wall and Plain surface on the Inner Wall, conforming to IS:14930 (Part I & II), cut to length as per Site Requirements for protection of UG Cable/ in PCC including Cutting Floors, etc. and Making Good the Same with Original Specification to match the Existing Adjoining Surfaces, etc., complete all as specified and as directed. \nNOTE : Quoted Unit Rate is inclussive of all Accessories for fixing of DWC Pipe with Walls, Roofs, Cable Tray, etc. | BI01010001010000000000000515BI0100001276 | 50 | RUNNING METRE |
165 | 2.054 | M&L Factory made Outdoor type Panel, made out of CRCA Sheet 16 SWG, Powder coated having Front Opening Shutter with proper Locking Arrangements, Totally Enclosed and mounted on Mild Steel Angle Iron Frame 40x40x5.0mm (4 No.) not less than 500mm height from Ground Level duly painted with Two Coats of Black Enamel Paint over a coat of Red Oxide Zinc Chrome Primer and grouting in Cement Concrete 1:2:4 (20mm graded stone aggregate) including necessary Earthwork, providng Electric Connections and Testing, complete all as specified and as directed and Comprising with the following :-\n(a) Copper Bus-bars 100 Amp rating, 4 Strip 450mm long - 01 Set \n(b) MCCB 40 Amp, 3 Pole, 10 kA, 415 Volt - 01 No. \n(c) MCB 40 Amp, SPN, 10 kA, 230 Volt - 03 No. | BI01010001010000000000000515BI0100001277 | 1 | EACH JOB |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy