Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project Supply Of Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project, As per Tender-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project Supply Of Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project. Submission Date for this Tender is 01-02-2021. Heat Detectors Tenders in As per Tender Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26566520
Corrigendum : Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project Supply Of Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project
Open Tender
Indian
Uttar Pradesh
As per Tender
01-02-2021

Tender Details

Supply Of Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project Supply Of Flame Proof Junction Boxes , Emergency Shutdown Switches And Manual Call Points For Kgpl Project , Supply , Flp / Wp Junction Box , Type C ( Nos . Of Terminals: 60 Nos . ; Bottom Entry: 1 No . - 1 1 / 4 & 1 No . - 1; Left Side Entry: 1 No . - 1 & 3 Nos . - 1 / 2; Right Side Entry: 2 No . - 1 & 2 Nos . - 1 / 2 ) Along With Flp Cable Glands & Flp Plugs For All The Cable Entries Of The Junction ( As Per Technical Specifications And Datasheets ) , Flp / Wp Junction Box , Type D ( Nos . Of Terminals: 24 Nos . ; Bottom Entry: 1 No . - 1; Left Side Entry: 3 Nos . - 1 / 2; Right Side Entry: 3 No . - 1 / 2 ) Along With Flp Cable Glands & Flp Plugs For All The Cable Entries Of The Junction ( As Per Technical Specifications And Datasheets ) , Flp / Wp Emergency Shut Down Push Button Switch ( With 2 Nos . Cable Entry Provision Of 1 / 2 Npt ) With Steel Hammer Chained With Main Unit . ( As Per Technical Specifications And Datasheets ) , Flame Proof And Wether Proof Junction Boxes Including Supply Of Ep / Wp Double Compression Cable Glands , Plugs For Unused Cable Entries Including Ep / Wp Certificates As Per Tender Specifications For Uv / Ir Flame Detectors , Ir Type Hydrocarbon Detectors & Is Heat Detectors In Hazardous Areas . ( As Per Technical Specifications And Datasheets ) , Manual Call Point ( Explosion Proof & Weather Proof ) For Hazardous Areas Along With All Mounting & Other Accessories ( As Per Technical Specifications And Datasheets )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Jan-2021 Corrigendum-1 Technical Bid 01-02-2021
2 21-Jan-2021 Corrigendum-2 Other 01-02-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Item: Flame proof Junction Boxes, Emergency Shutdown Switches & Manual Call Points
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply
2 1.01 FLP/WP Junction Box, Type C (Nos. of terminals: 60 nos.; Bottom entry: 1 No. - 1 1/4" & 1 No. - 1"; Left side entry: 1 No. - 1" & 3 Nos. - 1/2"; Right side entry: 2 No. - 1" & 2 Nos. - 1/2") along with FLP cable glands & FLP plugs for all the cable entries of the junction\n(as per Technical Specifications and Datasheets)\n BI01010001010000000000000515BI0100001113 600 EA
3 1.02 FLP/WP Junction Box, Type D (Nos. of terminals: 24 nos.; Bottom entry: 1 No. - 1"; Left side entry: 3 Nos. - 1/2"; Right side entry: 3 No. - 1/2") along with FLP cable glands & FLP plugs for all the cable entries of the junction\n(as per Technical Specifications and Datasheets)\n BI01010001010000000000000515BI0100001116 516 EA
4 1.03 FLP/WP Emergency Shut Down Push Button Switch (with 2 nos. cable entry provision of 1/2" NPT) with steel hammer chained with main unit.\n(as per Technical Specifications and Datasheets)\n BI01010001010000000000000515BI0100001119 163 EA
5 1.04 Flame proof and wether proof junction boxes including supply of EP/WP double compression cable glands, plugs for unused cable entries including EP/WP certificates as per tender specifications for UV/IR flame detectors, IR type hydrocarbon detectors & IS heat detectors in hazardous areas.\n(as per Technical Specifications and Datasheets)\n BI01010001010000000000000515BI0100001122 161 EA
6 1.05 Manual Call Point (Explosion Proof & Weather Proof) for hazardous areas along with all mounting & other accessories\n(as per Technical Specifications and Datasheets)\n BI01010001010000000000000515BI0100001125 88 EA
Disclaimer :