Maintenance Of Electrical Installation And Fans , Compound Light , Rmo Pump Set , Sub-Stations , Dg Sets , Fire Fighting System Installed In Various Police Station , Police Residential Complex Under Sub-Division M-4513 , Pwd Dhc , Nd/C , Delhi , New Delhi.-Delhi

Public Works Department-PWD has published Maintenance Of Electrical Installation And Fans , Compound Light , Rmo Pump Set , Sub-Stations , Dg Sets , Fire Fighting System Installed In Various Police Station , Police Residential Complex Under Sub-Division M-4513 , Pwd Dhc , Nd/C , Delhi . Submission Date for this Tender is 16-01-2021. Fire Fighting Consumable Tenders in New Delhi. Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26497245
Corrigendum : Maintenance Of Electrical Installation And Fans , Compound Light , Rmo Pump Set , Sub-Stations , Dg Sets , Fire Fighting System Installed In Various Police Station , Police Residential Complex Under Sub-Division M-4513 , Pwd Dhc , Nd/C , Delhi
Open Tender
Indian
Delhi
New Delhi.
16-01-2021

Tender Details

Maintenance Of Electrical Installation And Fans , Compound Light , Rmo Pump Set , Sub-Stations , Dg Sets , Fire Fighting System Installed In Various Police Station , Police Residential Complex Under Sub-Division M-4513 , Pwd Dhc , Nd / C , Delhi Replacement Of Fire Fighting Pipeline And Various Other Accessories For Fire Fighting System

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jan-2021 Amendment in List of Make in NIT and date extended Date 16-01-2021

Key Value

Document Fees
Refer document
EMD
INR 23940.0 /-
Tender Value
INR 11.97 Lakhs /-

BOQ Items

Name of Work: MOEI and Fans, Compound Light & RMO Pump set, Sub-Stations, DG sets, Fire Fighting system installed in various police Station & Police Residential complex under Sub-Division M-4513, PWD DHC&ND/C, Delhi. (SH:- Replacement of Fire Fighting pipeline and various other accessories for fire fighting System).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required \n(1) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.\n(2) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.\n(3) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts.\n(4) Suitable cement concrete foundation duly plastered with anti vibration pads. \nA) 1620 LPM at 56 meters Head\n 1 Nos.
2 2 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirrel cage induction motor TEFC type\nsuitable for operation on 415 volts, 3 phase, 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc as required alongwith Suitable cement concrete foundation duly plastered and with anti vibration pads. \na) 300 LPM at 56 meters Head\n 1 Nos.
3 3 Fabrication, supplying, Installation, testing & commissioning of Electrical control panel of cubical type construction, floor mounted type, fabricated out of 2mm thickness CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved colour and shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete, as per CPWD general specifications, as amended upto date with following in coming and Outgoings, suitable for operation on 415Volts, 3 phase, 50Hz, A.C. Supply with enclosure protection class IP 42 as required :\n\nINCOMING\na) 250Ampers, 50kA breaking capacity, 4 Pole MCCB, (Icu = 100% Ics)\nb) Digital Voltmeter 0-500Volts with selector switch c) Digital Ammeter (0-250 Ampers) with selector switch & CTs etc. \nd) LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps.\ne) Set of Copper Bus Bar of 300Ampers\n\nOUTGOING \n(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)\nMain Fire Pump\na) 125 Ampers, 50kA breaking capacity TPN MCCB, (Icu = 100% Ics) with fully automatic Star/Delta starter suitable for 60 HP capacity pump set with overload protection.\nb) Current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, \nc) selector switch for local/remote, auto/manual/OFF operation.\n\n
4 3.01 Jockey Pump\na) 63 Ampers, 50kA breaking capacity TPN MCCB, (Icu = 100% Ics) with suitable HP fully automatic Star/Delta starter with overload protection.\nb) Current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation.\nc) Selector switch for local/remote, auto/manual/OFF operation\n\nDIESEL ENGINE CONTROL\nControl for diesel engine comprising –\na) Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required.\nb) push buttons, start/stop in manual mode Indicating lamp for high/ Low Lubricate Oil pressure, High Water Temperature and Engine on indication Battery charger suitable for 12Volts /24 Volts DC with boost and trickle selector switch,\nc) 0-30 Volts DC volt meter and 0- 20 Ampers DC Ammeter alongwith all standard relays and accessories for automatic operation of diesel engine System Controller.\n\n 1 Nos.
5 4 Supplying and fixing of single headed internal/ external hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm diameter with cast iron wheel (duly ISI marked) conforming to IS 5290 (Type -Ampers) with blank Gunmetal/Stainless Steel cap and chain as required \na) Single headed Stainless steel\n 5 Nos.
6 5 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat (duly ISI marked) complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- \n\na) 80mm diameter 2 Nos.
7 5.01 b) 100mm diameter 1 Nos.
8 5.02 c) 150mm diameter 1 Nos.
9 6 Supplying and fixing of 63 mm diameter, 15 meter long RRL hose pipe with 63 mm diameter male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required \na) Stainless Steel (Grade 304)\n 8 Nos.
10 7 Supplying and fixing of first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. \na) 20 mm nominal internal diameter water hose thermoplastic (Textile reinforced) type -2, as per IS: 12585 20 mm nominal internal diameter gun metal globe valve & nozzle.\nb) Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm diameter stop gun metal valve & M.S. Pipe and socket.\n a) 30 meters\n 8 Nos.
11 8 Supplying & fixing of 63 mm diameter gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : \na) Stainless Steel (Grade 304)\n 8 Nos.
12 9 Supplying installation testing commissioning of MonoBlock motor pump set of 15 HP Capacity with Stainless Steel impellers, Stainless Steel shaft ,mechanical seal electrically driven by 3 phase, 415 Volts, 50 Hz, A.C. supply ,capable of delivering 500-1480 Liters per minute at a head 24-54 Meters complete with fitting ,connections complete as required. 2 Nos.
13 10 Supplying, installation, testing & commissioning of smoke detector with built in LED and mounting base complete with all connections etc as required. 30 Nos.
14 11 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermostat) type with mounting base complete with all connection etc as required. 50 Nos.
15 12 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc as required. 20 Nos.
16 13 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier including line matching transformer etc. complete as\nrequired.\n 20 Nos.
17 14 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities, as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. \na) 6 Zones 9 Nos.
18 14.01 b) 10 Zones 5 Nos.
19 15 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.\n 500 Meters
20 16 Less Credit for following dismantled material under buy back arrangement including dismantling etc. complete as required.\n\na) Main fire Pump 1 Nos.
21 16.01 b) Jockey Pump/ water supply pump set 2 Nos.
22 16.02 c) Fire hydrants/Hose Reel Drums 15 Nos.
23 16.03 d) Fire Fighting Panel 1 Nos.
24 16.04 e) 10/6 zone panels 14 Nos.
25 16.05 f) detector/sounder/MCP 120 Nos.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail