Supply Of Cardiology Implants At Rims , Ranchi-1 HARDWARE REQUIREMENT FOR CORONARY ANGIOPLASTY, PERMANENT PACEMAKER AND BALLOON MITRAL VALVOTOMY 2 CORONARY DIAGNOSTIC CATHETER FOR ENGAGEMENT OF SELECTIVE CORONARY OSTIUM FROM FEMORAL ROUTE 3 CORONARY DIAGNOSTIC CATHETER FOR ENGAGEMENT OF SELECTIVE CORONARY OSTIUM FROM RADIAL ROUTE 4 CORONARY GUIDING CATHETER 5 014 CORNONARY GUIDEWIRES 6 DRUG ELUTING STENTS 7 035 PTFE CORONARY CATHETER GUIDEWIRE J TIP 145 TO 170 CM 8 PRESSURE MONITORING LINE 9 HIGH PRESSURE LINE 10 PTCA KIT WITH Y CONNECTOR, TUOHY BORST VALVE AND 25 CM EXTENSION 11 INDEFLATOR FOR CORONARY ANGIOPLASY 12 CORONARY BALLOON CATHETER 13 UNFRACTIONATED HEPARIN 14 TEMPORARY PACING WIRE 6FR 15 VVIR PERMANENT IMPLANTABLE PACEMAKER 16 DOUBLE LUMEN BALLOON DILATATION CATHETER OF VARIOUS SIZES FOR PERCUTANEOUS TRANSMITRAL MITRAL COMMISUROTOMY WITH ALL ACCESSORIES (ROUND WIRE, SEPTAL DILATOR, J-WIRE FOR PTMC BALLOON, FEMORAL SVENOUS SHEATH) 17 8 FR MULLINS SHEATH FOR TRANS-SEPTAL ACCESS 18 032 PTFE J TIPPED WIRE 19 TRANSEPTAL PUNCTURE NEEDLE 70 CM LONG, CURVED TIP, 18 GAUGE WITH A DISTAL TAPER TO 21 GAUGE, PREFERABLY BROCKENBROUGH NEEDLE. 20 PIGTAIL CARDIAC CATHETERISATION CATHETER 6 FR 21 VASCULAR SHEATH FOR RADIAL ARTERY CANNULATION 22 VASCULAR SHEATH FOR FEMORAL ARTERY CANNULATION 23 HARDWARE REQUIREMENT FOR CORONARY ANGIOPLASTY 24 CORONARY DIAGNOSTIC CATHETER FOR ENGAGEMENT OF SELECTIVE CORONARY OSTIUM FROM FEMORAL ROUTEn• JUDKINS LEFT, JUDKINS RIGHT SIMILAR CURVES FROM OTHER MANUFACTURERSn• GUIDE CATHETERS TO BE PROVIDED IN 6FR SIZEn• VARIOUS CURVES LIKE 3, 3.5, 4 TO BE PROVIDED FOR THE CATHETERS WHEREVER APPLICABLEn 25 CORONARY DIAGNOSTIC CATHETER FOR ENGAGEMENT OF SELECTIVE CORONARY OSTIUM FROM RADIAL ROUTEn• TIGER CATHETER SIMILAR CURVES FROM OTHER MANUFACTURERSn• GUIDE CATHETERS TO BE PROVIDED IN 5FR SIZEn 26 CORONARY GUIDING CATHETER FOR ENGAGEMENT OF SELECTIVE CORONARY OSTIUM n• JUDKINS LEFT, JUDKINS RIGHT, EXTRA BACK UP GUIDE FOR LEFT, AMPLATZ GUIDE FOR LEFT, AMPLATZ GUIDE FOR RIGHT OR SIMILAR CURVES FROM OTHER MANUFACTURERSn• GUIDE CATHETERS TO BE PROVIDED IN 6FR AND 7FR SIZESn• VARIOUS CURVES LIKE 3, 3.5, 4 TO BE PROVIDED FOR THE CATHETERS WHEREVER APPLICABLEn 27 014 CORNONARY GUIDEWIRES OF STANDARD LENGTH 175 TO 190 CM : FOLLOWING TYPES OF PTCA WIRES TO BE PROVIDEDn• GUIDE WIRES WITH TIP LOAD < 1 GRAMn• GUIDE WIRES WITH TIP LOAD 1 TO 3 GRAMSn• GUIDE WIRES WITH TIP LOAD > 6 GRAMSn• GUIDE WIRES WITH HYDROPHILIC COATINGn 28 DRUG ELUTING STENTS OF VARIOUS DIAMETERS ( 2.5 MM, 2.75 MM, 3.0 MM, 3.5 MM, 3.5 MM, 4 MM) AND VARIOUS LENGTHS (12MM TO 40MM, AS PROVIDED MY MANUFACTURER) WITH THE FOLLOWING SPECIFICATIONSn• 014 PTCA GUDEWIRE COMPATIBLEn• MONORAIL DESIGNn• EVEROLIMUS, SIROLIMUS OR ZOTAROLIMUS ELUTINGn• STRUT THICKNESS < 100 UMn• CoCr OR PtCr BASED STRUT DESIGNn 29 035 PTFE CORONARY CATHETER GUIDEWIRE J TIP 145 TO 170 CM 30 PRESSURE MONITORING LINE 200 CM MALE TO FEMALE 31 HIGH PRESSURE LINE MALE TO FEMALE 120 CM WITH BRAIDED TUBING WITH MAXIMUM PRESSURE DELIVERY OF 1200 Psi 32 PTCA KIT WITH Y CONNECTOR, TUOHY BORST VALVE AND 25 CM EXTENSION CONTAINING TORQUER FOR PTCA WIRE AND PTCA WIRE INSETION TOOL 33 INDEFLATOR FOR CORONARY ANGIOPLASY WITH MAXIMUM PRESSURE CAPACITY OF 30 ATM. 34 CORONARY BALLOON CATHETER FOR CORONARY ANGIOPLASTY WITH FOLLOWING SPECIFICATIONSn• 014 PTCA WIRE COMPATIBLEn• MONORAIL DESIGNn• 140 CM LENGTH OR MORE WITH MAXIMUM PROFILE <2.5 FRn• COMPLIANT BALLOONS WITH DIAMETER 1.25MM, 1.5MM, 2MM, 2.5MM. 2.75MM.n• NON COMPLIANT BALLOONS WITH DIAMETER 2.5MM, 2.75MM, 3MM, 3.5MM,4MMn• VARIOUS LENGTHS FOR BOTH COMPLIANT (10MM, 12MM, 15MM) AND NON-COMPLIANT (8MM, 10MM, 12MM, 15MM) BALLOONS TO BE PROVIDED.n 35 UNFRACTIONATED HEPARIN 1000IU/ml 5 ml BOTTLE 36 VASCULAR SHEATH FOR RADIAL ARTERY CANNULATION – 5 Fr, 6 Fr 37 VASCULAR SHEATH FOR FEMORAL ARTERY CANNULATION – 6 Fr, 7 Fr, 8 Fr 38 HARDWARE REQUIREMENT FOR PACEMAKER IMPLANTATION 39 TEMPORARY PACING WIRE 6FR 40 VVIR PERMANENT IMPLANTABLE PACEMAKERn• US FDA approved pacemaker with lead & accessories.n• All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto capture/output management facilities.n• Must have Ventricular Capture Management.n• Monitor the integrity of lead and switch polarity in case of issuen• 1.5 Tesla MRI Compatiblen• The Size of lead should be 7F or less.n• The Lead must be steroid eluting and should be both bipolar and unipolar configuration.n• Must have both active and passive fixation endocardial leads available.n• Must have rate response which allows rate profile optimization.n• Company must provide at least one programmer exclusively to the department of cardiology RIMS Ranchi.n• Company must provide its trained technical person for each implantation and for follow up programming whenever required.n• Company must quote only the latest model of devices commercially available.n 41 HARDWARE REQUIREMENT FOR BALLOON MITRAL VALVOTOMAY (PTMC) 42 DOUBLE LUMEN BALLOON DILATATION CATHETER OF VARIOUS SIZES FOR PERCUTANEOUS TRANSMITRAL MITRAL COMMISUROTOMY WITH ALL ACCESSORIES (ROUND WIRE, SEPTAL DILATOR, J-WIRE FOR PTMC BALLOON, FEMORAL SVENOUS SHEATH) 43 8 FR MULLINS SHEATH FOR TRANS-SEPTAL ACCESS 44 032 PTFE J TIPPED WIRE 45 TRANSEPTAL PUNCTURE NEEDLE 70 CM LONG, CURVED TIP, 18 GAUGE WITH A DISTAL TAPER TO 21 GAUGE, PREFERABLY BROCKENBROUGH NEEDLE. 46 PIGTAIL CARDIAC CATHETERISATION CATHETER 6 FR 47 PRESSURE MONITORING LINE 200 CM MALE TO FEMALE 48 UNFRACTIONATED HEPARIN 1000IU/ml 5 ml BOTTLE