Provision Of New Electric Poles And Street/Security Lights At Various N Darken Places Under Age E/M-Ii Of Ge ( Utility-I ) , Visakhapatnam , Excavation In Trenches N . Exc 1 . 5 M Wide And Not Exc 1 . 5 M Depth And Getting Out In Soft / Loose Soil Complete All As Specified And Directed . , Returning And Filling In Of Excavated Material Any Type Including Spreading , Levelling , Watering And Well Ramming In Layers Not Exceeding 25 Cm Each Complete All As Specified And Directed . , Removal Of Surplus Excavated Material Of Any Type To A Distance Not Exceeding 50 M And Depositing Where Directed At A Level Not Exc . 1 . 5 M Bove The Starting Point Complete All As Specified And Directed . , Supply And Spreading Clean Dry Sand For Cable Cushioning In Trenches Complete All As Specified And As Directed . ( Note: Punned Thickness Only Shall Be Measured ) , Supply And Laying Sub Class B Bricks Of Old Size ( Approved Size Locally Available ) Laid Along Alignment Of Cable As Protection To Cable In Trenches Complete All As Specified And Directed By Engineer-In-Charge , M&L For Gi Pipe Light Grade 50 Mm Dia Laid Along Road Crossings / Plinth Protection With Suitable Fittings For Cable Protection Or Fixed To The Pole/ Wall Complete All As Specified And Directed By Engineer-In-Charge . Make : Surya Roshni Ltd / Tata / Jindal Steel / Prakash , Cutting The Tarmac / Hard Standings And Excavating In Trenches Across The Road For Laying Cable Including Making Good The Excavated Portion By Means Of Pcc 1:3:6 , Type C1 Matching With The Surroundings All As Directed . , Supplying , Laying , Testing And Commissioning Lt Xlpe Insulated , Armoured Heavy Duty Electric Frls Cable Of Following Sizes , 1100 Volts Grade With Stranded Aluminium Conductor Laid In Trenches / Passing Through Pipe / Duct/ Road Crossing /Fixed On Poles / Walls Complete All As Specified And Directed . Make: Havells / Gloster / Kei Industries Ltd / Polycab / Asian Cables / Finolex[Note: The Rate Quoted Shall Inclusive Of Termination At Ends With Suitable Aluminium Lugs Where Required] , ( A ) 25 Sqmm 4 Core , ( B ) 16 Sqmm 4 Core , Supply And Erection , Testing And Commissioning Of Hot Dip Galvanised Octagonal Pole Of 7 . 5 M Height , Top Dia 70 Mm Bottom Dia 135 Mm , Base Plate 225Mm X 225 Mm X 16 Mm , Foundation Bolt M20 X 700 - 04 Nos Complete With Single Arm Gi Bracket Of Suitable Size And Including Built In Connecter Control Box With Locking Arrangement Along With With 5/6 Amps Mcb - 01 No , 50 Amps Rated 3 Pole Connector- 01 Nos , Neutral Link Mounted And Din Rail Suitable Size For Mounting Mcb/Connector Etc Complete In The Box And Flexible 3 Core 1 . 5 Sqmm Copper Connecting Cable From Control Box To Fitting Complete All As Specified And Directed . ( Make: C&N / Utkarsh / Ge Or Equivalent ) . , Supply And Erection , Testing And Commissioning Of Hot Dip Galvanised Octagonal Pole Of 10 M Height , Top Dia 120 Mm Bottom Dia 300 Mm , Base Plate 450Mm X 450 Mm X 16 Mm , Foundation Bolt M24 X 750 - 04 Nos Complete With Gi Angle Bracket Of Size 50X50x6mm And Suitable Nuts , Bolts And Washers For Fixing Of 2/4 Nos 150 W Flood Light Fittings And Including Built In Connecter Control Box With Locking Arrangement Along With With 5/6 Amps Mcb - 01 No , 50 Amps Rated 3 Pole Connector- 01 Nos , Neutral Link Mounted And Din Rail Suitable Size For Mounting Mcb/Connector Etc Complete In The Box And 2 Runs Of Flexible 3 Core 1 . 5 Sqmm Copper Connecting Cable From Control Box To Fitting Complete All As Specified And Directed . ( Make: C&N / Utkarsh / Ge Or Equivalent ) . , Note For Sl Item No 9 . 00 & 10 . 00 :The Rate Quoted Shall Be Inclusive Of The Following: ( A ) The Required Rcc Foundation Shall Be Designed As Per Manufacturers Instructions Considering Safe Bearing Capacity Of Soil As 10 T/M2 Which Shall Be Got Approved By Ge Before Execution Of Work . . ( Ii ) Necessary Earth Work , Rcc M-20 Shallow Foundation , Reinforcement Steel As Per Design , Foundation Bolts Manufactured With Special Steel Along With Nuts , Washers , Anchor Plates & Templates Complete Set Etc . ( Iii ) Erection And Commissioning Of The Octagonal Pole With The Help Of Suitable T & P . , Supply & Fixing Led Street Light Fitting For Fixing On Hot Dip Galvanised Octagonal Pole Of 7 . 5/10 . 00 Mtr Height Comprising Of Epoxy Powder Coated Housing , Enclosed With Glass Cover In Frame ( With Total Lumen Output Not Less Than 10000 Lumens And Suitable Wattage Efficiency Not Less Than 95 Lumens/Watt ) With Ingress Protection Ip 65/66 And Spd Of Capacity 10 Kv Including Necessary Clamps Etc Complete And Testing On Completion All As Specified And As Directed . ( Make : Havells Model No . Endurapearlmagnumsl 120Wled757pasytotgastho Or Crompton Model Lstp-120-Cdl-M Or Its Equivalent In Philips/ Ge / Wipro ) , Supply And Fixing Timelite Distribution Boards ( Street Light Dbs ) Of Rating 65 Amp , 3 Pole/230V Digital Time Switch Complete All As Directed . Make: Indo Asian / Hpl / Havells , Supply & Fixing Led Flood Light Fitting 150 W On Hot Dip Galvanised Octagonal Pole Of 10 M Height , Top Dia 120 Mm Dia , Comprising Of Epoxy Powder Coated Housing , Enclosed With Glass Cover In Frame , Suitable Wattage For Efficiency Not Less Than 95 Lumens/Watt With Ingress Protection Ip 66 And Spd Of Capacity 10 Kv Etc Complete With Necessary Connection And Testing On Completion All As Specified And As Directed . ( Make: Cg Model No . Lfln-150-Cdl/60-M Or Havells Model No . Jetairisfls150wled757psymltg Or Its Equivalent In Philips/Ge/Wipro ) . , Supply & Fixing Led Flood Light Fittings 250 W Comprising Of Epoxy Powder Coated Housing , Enclosed With Glass Cover In Frame , Suitable Wattage For Efficiency Not Less Than 95 Lumens/Watt With Ingress Protection Ip 66 And Spd Of Capacity 10 Kv Etc Complete With Necessary Connection And Testing On Completion All As Specified And As Directed . ( Make: Cg Model No . Lsfo-250-Cdl/60M Or Its Equivalent In Havells/ Philips/ Ge/ Wipro ) . , Earthing Complete With Galvanised Steel Earthplate Of Size 60X60cmx6 . 3Mm Thick Electrode And 32X6mm Gi Strip As Earth Lead , Buried Directly In Ground ( Earth Pit Not Less Than 2 . 25M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1 . 5M Below Ground Level , Connected To 32X6mm Earth Strip By Means Of Nuts , Bolts , Check Nuts And Washers Of Gi All As Shown In Electrical Plate No . 3 Of Ssr Part-I , Connected To Earth Test Terminal Point All As Specified Or As Indicated Including Testing On Completion ( Rates Inclusive Of Neccessary Excavation In Any Type Of Soil , Earth Work , Pcc Pit , Ci Cover , Funnel With Watering Pipe , Suitable Size Of Light Grade Gi Protection Pipe For Earth Strip In Ground Etc . All As Required At Site For Complete Earthing ) .