Military Engineer Services-MES has published Repair To Flooring , Roof , Trusses , Plastering , And Miscellaneous B/R Works At Afs Amla. Submission Date for this Tender is 14-01-2021. Shed Construction Tenders in GE AF Amla Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-01-2021 |
Name of Work: Repair to flooring, roof, trusses, plastering, and miscellaneous B/R works at AFS Amla. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling asbestos cement/ GI (corrugated, semi corrugated) sheets including ridges in roof covering complete all as directed. | 1157 | sqm. | |
2 | 2 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. | 160 | sqm. | |
3 | 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. | 12 | sqm. | |
4 | 4 | M&L for fixing only 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc., fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.\nNote: The rate quoted by contractor deemed to be inclusive of provision of L-type or J-type or cranked hook bolts. | 250 | sqm. | |
5 | 5 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc., fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. | 600 | sqm. | |
6 | 6 | M&L for 6mm thick asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J type or cranked hook bolts complete all as specified and directed. | 150 | Rm | |
7 | 7 | Dismantling timber scantling 40 sq. cm and over in section and in any position, unframed work all as specified and as directed. | 3.75 | Cu.m | |
8 | 8 | M&L for second class hard wood scantling, clean sawn and fixed all as specified and directed. | 3.75 | Cu.m | |
9 | 9 | M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and directed | 120 | sqm. | |
10 | 10 | Dismantling timber fillets, rails, posts, purlins, rafters etc unframed work under 40 sq. cm in section all as specified and as directed. | 300 | Rm | |
11 | 11 | M&L for second class harwood plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or bradsof size Exc13 & n. exc 25 sq.cm all as specified and directed. | 100 | Rm | |
12 | 12 | M&L for second class harwood plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or bradsof size Exc 3 & n. exc 6 sq.cm all as specified and directed. | 200 | Rm | |
13 | 13 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets all as directed. | 682 | sqm. | |
14 | 14 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified\n | 617 | sqm. | |
15 | 15 | M&L for 4mm thick, non-asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.\n | 617 | sqm. | |
16 | 16 | M&L for Fixing only 4 mm thick non- asbestos cement plain building boards, fixed/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. | 65 | sqm. | |
17 | 17 | Dismantling structural steel work, including doors, gates but excluding framed truss, etc., complete all as specified and directed. | 7.6 | Qtl | |
18 | 18 | S&F of expanded metal cut to length, bent to shape required and tying with and including fixing with galvanised steel staple to steel members, weight n.exc 4 kg/sqm, complete all as specified and directed. | 30 | Kg | |
19 | 19 | S&F Steel work in tubular trusses, purlins, rafter including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161 - 1979 grade St.-240 all as specified and directed. | 730 | Kg | |
20 | 20 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm width or girth, including necessary preparation of surfaces complete all as specified and directed. | 480 | sqm. | |
21 | 21 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) all as specified and as directed. | 98.1 | Cu.m | |
22 | 22 | M&L for 40mm thick plain cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as in sub base/floor finished even and smooth without using extra cement all as specified and directed. | 140 | sqm. | |
23 | 23 | M&L for 100mm thick Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floors, surface finished even and smooth without using extra cement including use and waste of form work to divide the area in panels complete all as specified and directed. | 340 | sqm. | |
24 | 24 | M&L for 150mm thick Plain Cement Concrete 1:1½ :3 type A-1 using 20mm graded stone aggregate as in floors, surface finished even and smooth without using extra cement including use and waste of form work to divide the area in panels complete all as specified and directed. | 280 | sqm. | |
25 | 25 | M&L for 75 mm thick Plain Cement Concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even and fair (without using extra cement) including use and waste of form work to divide the area in panels complete all as specified and directed. | 220 | sqm. | |
26 | 26 | M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm thick concrete slab complete all as specified and directed. | 18 | Ten Rm | |
27 | 27 | M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 150mm thick concrete slab complete all as specified and directed. | 18 | Ten Rm | |
28 | 28 | Taking down cement plaster on brick or stone works including taking out joints, hacking, of key and scrubbing down with water complete all as specified and directed. | 1000 | sqm. | |
29 | 29 | Demolition of Brickwork or stone/ boulder masonry, built-in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, etc., complete all as specified and directed. | 12 | Cu.m | |
30 | 30 | M&L for brick work with modular size fly ash bricks having minimum compressive strength of 75 kg/cm. sq, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed. | 12 | Cu.m | |
31 | 31 | M&L for rendering 15 mm thick Cement Mortar 1:6 over brick or concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed. | 600 | sqm. | |
32 | 32 | M&L for rendering in two coats of 10 mm thick in CM (1:6) and 5 mm thick in CM (1:4) mixed with integral water proofing compound in finishing coat, finished even and smooth without using extra cement complete all as specified and as directed. \nNote: Water proofing compound shall be measured and paid separately as supply only. | 450 | sqm. | |
33 | 33 | M&L for 5mm thick rendering as in ceiling on fair faces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed. | 100 | sqm. | |
34 | 34 | M&L for 10mm thick rendering as in ceiling on fair faces in cement mortar 1:3 mixed with integral water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed. | 50 | sqm. | |
35 | 35 | Supply only approved integral water proofing compound. | 25 | Kg | |
36 | 36 | M&L for preparing newly plastered surfaces of internal walls and applying two coats of oil emulsion distemper, white or tint over a coat of chalk whitening primer and filling of holes and depressions with wall putty including preparation of surfaces complete all as specified and directed. | 600 | sqm. | |
37 | 37 | M&L for preparing newly plastered surface of wall and applying two coats of cement based paint complete all as specified and directed. | 500 | sqm. | |
38 | 38 | M&L for preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed. | 100 | sqm. | |
39 | 39 | Taking down steel rolling shutters of size as mentioned below of any description and refixing the same after carrying out repairs, oiling and greasing including replacing spare parts such as like bearing, tension spring/gear operated lever, hood cove, weldings etc., complete all as directed for the following sizes. \nNote:- Supply of spare parts like bearing, tension spring/gear operated lever, hood cover, and shaft will be measured & paid separately as supply only under the relevant item of schedule ‘A.’ | |||
40 | 39.01 | Area of shutters not exceeding 7.20 Sqm | 10 | Each Job | |
41 | 39.02 | Area of shutters exceeding 7.20 sqm but not exceeding 15.00 sqm | 10 | Each Job | |
42 | 39.03 | Area of shutters exceeding 15.00 sqm but not exceeding 22.00 sqm | 10 | Each Job | |
43 | 40 | Supply only ball bearing heavy duty suitable for 40mm bore MS axle/ anchorage rod roller No-3206 or equivalent to suit proper functioning of rolling shutter. | 12 | Each | |
44 | 41 | Supply only wire spring of rolling shutter, 90mm dia and 450mm long, standard quality with MS wire not less than 8mm dia. | 10 | Each | |
45 | 42 | Supply only MS pulley 40mm dia of approved make suitable for existing rolling shutters at site. | 12 | Each | |
46 | 43 | Supply only lever gear box with crank handle and gear assembly 11 inch size all as specified and directed. | 2 | Each | |
47 | 44 | Supply only axle/ anchorage pipe 40mm dia MS black pipe heavy grade cut to size for full length (single peace) all as specified and as directed. | 30 | RM | |
48 | 45 | Supply only rolling hood cover 1.00 mm thick MS sheet bend to shape cut to length with a coat of zinc chrome primer | 36 | sqm. | |
49 | 46 | S&F in repairs 1.25mm thick Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle all as specified and directed. | 45 | sqm. | |
50 | 47 | S&F in repairs rolling shutter profile inter locking both section formed from cold rolled sheel stip 1.25mm thick single peace cut to length rebated with mild steel clips secured either ends minimum width of profile 75mm with and including applying a coat of red oxide zinc chrome priper complete all as specified and directed. | 150 | sqm. | |
51 | 48 | S&F in repairs MS wicket door of standard size and shape for the rolling shutter of approved quality with a coat of red oxide zinc chrome primer fabricated using MS sheet of 3.15mm thick with MS angle iron 40x40x6mm at the bottom including sliding bolts with the arrangement of locking by pad lock and handle both 02 Nos at each corner to be fitted both sides may be 20x6mm flat iron complete all as specified and directed.\nNote: For payment purpose area of a wicket door is only considered for measurement.\n | 6 | sqm. | |
52 | 49 | S&F in repairs mild steel guide channel of size 65mm depth, 25mm width and thickness not lesser than 3.15mm fixed with a mild steel plate including one coat of red oxide zinc chrome primer, providing PCC type B-1, 1:2:4 as in bed block and finishing the disturbed surface by using cement mortar 1:4 to match with the existing surface complete all as specified and directed. | 15 | RM | |
53 | 50 | S&F in repairs mild steel ‘T’ hinges of size not exceeding 450mm in length, width n. exc 60mm and thickness n. exc 6 mm as in steel gate of size exceeding 2 sqm but not exceeding 3 sqm per leaf complete including welding and necessary adjustment as required at the site all as specified and directed. | 60 | Each Job | |
54 | 51 | S&F in repairs mild steel ‘L’ type round hinges of diametre n. exc 16mm as in steel gate of size exceeding 2 sqm but not exceeding 3 sqm per leaf complete including replacement of wall supporting ring, welding and necessary adjustment as required at the site all as specified and directed. | 60 | Each Job | |
55 | 52 | S&F in repairs 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane including hacking out old sheet glass complete all specified and directed. | 18 | sqm. | |
56 | 53 | S&F in repairs 4mm thick, figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sq. m in each pane including hacking out old sheet glass complete all specified and directed. | 6 | sqm. | |
57 | 54 | S&F in repairs 12mm x 12mm size stainless steel wire mesh made using 0.71mm dia stainless steel wire, fixed with tinned tacks of stainless steel wire staples complete all as specified and directed. | 200 | sqm. | |
58 | 55 | M&L for preparation of old painted steel surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 780 | sqm. | |
59 | 56 | M&L for preparation of old painted wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 200 | sqm. | |
60 | 57 | M&L for washing, rubbing down and stopping of distempered and painted surfaces of old walls and applying one coat of oil bound distemper on wall surfaces complete all as specified and directed.\n | 300 | sqm. | |
61 | 58 | M&L for preparation of old surfaces on walls by brooming down and steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots etc, and applying one coat of white wash all as specified & as directed. | 300 | sqm. | |
62 | 59 | M&L for preparation of old surfaces on walls by brooming down and steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots etc, and applying two coat of white wash all as specified & as directed. | 100 | sqm. | |
63 | 60 | M&L for applying two coat of acrylic emulsion weather coat "Apex paint" over one coat of cement primer including cracks filled with exterior wall care putty wherever necessary after preparation to the existing exterior old painted plastered surface including cornices etc., after complete removal of existing treatment (i.e. white wash, colour wash, cement base paint, synthetic enamel paint etc. from wall surface) complete all as specified and directed. | 500 | sqm. | |
64 | 61 | Note:- (i) The amount against Schedule of Credit mentioned in tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contarct Sum for Acceptance. |