| 1 | 1 | Civil and Structure | item1 | | |
|---|
| 2 | 2 | supplying,installation and fixing of corrugated G.S. sheet roofing including vertical / curved\nsurface fixed with polymer coated J or L hooks, bolts and nuts 8 mm\ndiameter with bitumen and G.I. limpet washers or with G.I. limpet\nwashers filled with white lead and including a coat of approved steel\nprimer and two coats of approved paint on overlapping of sheets\ncomplete (upto any pitch in horizontal/ vertical or curved surfaces)\nexcluding the cost of purlins, rafters and trusses and including cutting\nto size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m2. with labour,tools and techniques. | item2 | 1 | sqmtr |
|---|
| 3 | 3 | Providing flashing of 40 cm over all width in plain, G.S. sheet fixed\nwith polymer coated J, or L hooks, bolts and nuts, G.I. limpet and\nbitumen washer complete, bent to shape and fixed in wall with\ncement mortar 1:3 (1cement : 3 coarse sand)\n1.00mm thick sheet | item3 | 1 | mtr |
|---|
| 4 | 4 | Demolishing cement concrete/R.C.C. work manually/ by mechanical means\nincluding disposal of material within 50 metres lead as per direction of\nEngineer-in-charge. | item4 | 1 | cum |
|---|
| 5 | 5 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. | item5 | 1 | sqm |
|---|
| 6 | 6 | Providing and fixing Steel Rebarring in coloums and beams as directed by enginner in charge. | | | |
|---|
| 7 | 7 | 10 mm | item7 | 1 | Nos. |
|---|
| 8 | 8 | 12 mm | item8 | 1 | Nos. |
|---|
| 9 | 9 | 16 mm | item9 | 1 | Nos. |
|---|
| 10 | 10 | 20 mm | item10 | 1 | Nos. |
|---|
| 11 | 11 | 25 mm | item11 | 1 | Nos. |
|---|
| 12 | 12 | Carriage of earth (Soil) - with lead of 6 km with man and machinery. | item12 | 1 | cum |
|---|
| 13 | 13 | Providing and fixing in position bitumen impregnated fiberboard confirming to IS: 1838 in\nexpansion joints including the cost of primer sealing compound. 25mm thick | item13 | 1 | sqmtr |
|---|
| 14 | 14 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as\nper design to match the colour / shade of wall treatment.Aluminum fluted strips 2 mm thick | item14 | 1 | mtr |
|---|
| 15 | 15 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). | item15 | 1 | sqm |
|---|
| 16 | 16 | Providing & fixing ball bearing for rolling shutters. | item16 | 1 | each |
|---|
| 17 | 17 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. | | | |
|---|
| 18 | 18 | Exceeding 16.80 Sqm in the area. | item18 | 1 | sqm |
|---|
| 19 | 19 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge. (area of grill to be measured). | item19 | 1 | sqm |
|---|
| 20 | 20 | Foundation Bolts 20mm (600 mmin length) | item20 | 1 | Nos |
|---|
| 21 | 21 | Foundation Bolts 20mm (1200-1500 mm in length) | item21 | 1 | Nos |
|---|
| 22 | 22 | SANITARY FIXTURES & C.P.FITTINGS | | | |
|---|
| 23 | 23 | Providing and fixing BRASS ball valve with cenemnt solvant complete in all respect. | | | |
|---|
| 24 | 24 | 32 mm dia. nominal bore | item24 | 1 | EACH |
|---|
| 25 | 25 | Providing and fixing M.S. structural work fabricated from standard sections, (MS\nrounds, angles, channels etc.) including cutting to size, drilling, welding, including cost\nof fasteners, clamps in RCC structural members as directed, including two or more\ncoats of synthetic paint over one coat of primer after surface preparation including\ncutting and making good walls. | item25 | 1 | kg |
|---|
| 26 | 26 | Providing, laying and jointing light duty non-pressure NP2 class S/S R.C.C pipes with\ncollars jointing with stiff mixture of cement mortar in the proportion of 1:2 (1 cement\n: 2 fine sand) including curing, testing of joints etc. complete in all respects.350 mm dia | item26 | 1 | mtr |
|---|
| 27 | 27 | Providing & fixing of uPVC SWR pipes (Type-A) conforming to IS 13592 along with all\nrequired fittings like tees, bends, crosses with or without access doors jointed with\napproved solvent cement fixed to walls with clamps complete including angle\nsupports, brick work (slab/beam/wall) and making good the floors and walls with\ncement mortar where required complete of outer diameter.(Rain water & Vent\nPipes)160mm outer dia. | item27 | 1 | mtr |
|---|
| 28 | 28 | Fire Hydrent and sprinkler system | | | |
|---|
| 29 | 29 | Supplying, fixing, testing commissioning of butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. | | | |
|---|
| 30 | 30 | 65 mm dia | item30 | 1 | Each |
|---|
| 31 | 31 | Angle valve 15 mm | item31 | 1 | Each |
|---|
| 32 | 32 | Shifting and installation,testing,commssioning ,repair of Hitachi make 16.5 Tr. Split air conditioning both indoor and outdoor unit as per OEM guidelines.( the outdoor unit is lying on first floor is to be shifted to 2nd/3rd floor. The contractor should check the outdoor/indoor unit and quote the rates for proper functioning as lump sum price per machine.) | item32 | 1 | each |
|---|
| 33 | 33 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge. (area of grill to be measured). | item33 | 1 | sqm |
|---|
| 34 | 34 | Electrical | | | |
|---|
| 35 | 35 | SITC of 11KV, 630 A, 25 kA / 1 Sec, SF6 / VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio ( 15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/v3) , Fuses , IP42 Protection, 4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection ( High oil temperature , Buchholz protection ,high winding temperature), power pack 2 x 12 V,etc complete in all respect Ready To Use.(RTU/RMU). as per detailed specification enclosed seprately. | item35 | 1 | Each |
|---|
| 36 | 36 | supply, installation, testing and commissioning of the following Air Insulated type bus duct suitable for following amps rating (50 KA for 1 Sec) bus duct of Copper bus bars including necessary supports, fabricated out of 1.6 mm thick CRCA sheet steel, painted with RAL 7035 Paint Shade including 2 nos. of 30x5 mm Cu earthing conductor throughout the lengh of the bus duct. ( Phase sequence shall be matched ), Outdoor bus duct should have canopy arangment on top , bimetal strip to be porovided at connection points of Cu & Aluminium bus. | | | |
|---|
| 37 | 37 | 1600 amps TPN Air Insulated bus ducts ( from TRF to MLTP) | item37 | 1 | RM |
|---|
| 38 | 38 | End Termination Trf End | item38 | 1 | No. |
|---|
| 39 | 39 | End Termination Panel End suitable for Aluminium Bus Bar connection of panel | item39 | 1 | No. |
|---|
| 40 | 40 | Supply and fixing of supply / return linear air grilles made out from extruded aluminum, powder coated as required. | item40 | 1 | Sq.m |
|---|
| 41 | 41 | Supply and fixing of 2 way / 3 way Supply air\ndiffusers of extruded aluminum with dampers,\npowder coated as specified and complete with Flush,\n20mm flanges with PVC gasket, removable core type,\nsquare, rectangular as required. | item41 | 1 | Sqm. |
|---|
| 42 | 42 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required. | | | |
|---|
| 43 | 43 | 12.7 mm | item43 | 1 | mtr |
|---|
| 44 | 44 | 15.88 mm | item44 | 1 | mtr |
|---|
| 45 | 45 | 19.05 mm | item45 | 1 | mtr |
|---|
| 46 | 46 | 22.2mm | item46 | 1 | mtr |
|---|
| 47 | 47 | S & F of Hard rigid PVC (20/25mm) drain piping with\n6mm thick nitrile rubber insulation. . | item47 | 1 | Mtr |
|---|
| 48 | 48 | Making hole in stone masonary/ RCC with core cutter\nfor accomodating refrigerant pipe/ drain pipe for\nsplit/ cassattee/ ductable AC \n50mm to 150mm | item48 | 1 | MTR |
|---|
| 49 | 49 | Supply,installation,testing& commissiong of 1 no. Digital Meter, 96x96 mm with RS 485 Port, CL 1.0 with 3 no. CT, 630/5A,CL 1.0,15 VA. 3no. MCB,6 Amp SP,10 KA, C-curve with all necessary wiring to be installed in exsisting feeders of main LT Panel. | item49 | 1 | no |
|---|
| 50 | 50 | supplying and charging of fresh refrigerant and testing of performance of 16.5 Tr. Hitachi Make split air conditiong equipment as per OEM specification. | item50 | 1 | kg |
|---|