| 1 | 1 | Earthwork in surface excavation for levelling and lowering the ground manually (other than foundation of buldings, culverts, road drains and trenches of pipe lines and cables) and removing the excavated surface levelled and neatly dressed earth to be levelled inculding breaking of clods and neatly dressed as per specifications and completed as per Engineer directions. | 1 | 1.85 | Cum |
|---|
| 2 | 2 | Spreading and forming the excavated earth to required level, slope for an average thickness of 75mm. In all classes of soils inculding breaking clods and tamping manually alround the bulding and low laying areas complete as per specifications and Engineer directions. | 1.1 | 52.065 | Cum |
|---|
| 3 | 3 | Providing and laying in position Plan cement concrete of mix 1:3:6 with OPC @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.892cum and fine aggregates @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted,in foundation inculding cost of all materials, labour, HOM curing complete as per specifications and Engineer directions. | 1.2 | 9.63 | Cum |
|---|
| 4 | 4 | Providing and laying in position plain cement concrete of Mix M20 with OPC @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregtes @ 0.43cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted,in foundation, plinth and cills, inculding cost of all materials, labour, HOM curing complete as par specifications and complete as per Engineer directions. | 1.3 | 5.21 | Cum |
|---|
| 5 | 5 | Providing and laying in position reinforced cement concrete of Design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggrerates @0.69cum and fine aggregates @0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmes-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) inculding attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., inculding cost of all materials, labour, HOM curing, complete as per Specification and Engineer directions. | 1.4 | 6.63 | Cum |
|---|
| 6 | 6 | Providing T.M.T steel reinforcement for R.C.C work inculding straihtening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) cost of materials, labour, HOM complete as per Specifications. Specification and Engineer directions. | 1.5 | 0.27 | Tonne |
|---|
| 7 | 7 | Providing, fabricatin, assembling and fixing in position aluminium partitions using sections in combination of plai, single groove as per requiremwnts for the frames of overall size 101.6mm x 44.45 mm, 3.18 mm thick having section weight, plain sections 2.40 kg/3 single groove section 2.541 kg/m and double groove section 2.683 kg/m and bottom member 114.3 mmx 44.45 mm, 3.18 mm thick and 2.6.46 kg/m; aluminium louvers of size 77.6mmx 27.6 mm, 1.7mm. thick section weight 0.483 kg/m; bottom portion approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m c to c; sections are cut to the required lengths, joints miltered and corners grinded sub dividing frames tennoned and riveted to frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, raw plugs and teak wood gutties to RCC columns or masonrt on sides RCC lintels or beams attop and floor at bottom, including cutting, chistling and making good with cement mortor to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9 m from floor level; and 5.5 mm thick plain glass for middle portion viz., 0.9m to 2.13m and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm with thickness of 0.9 mm weight 0.124 g/m; aluminium sections pre treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non adherence of motars ar any other sticky materials; vertical menbers embedded in the flooring by making suitable size holes and fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materilas, fixtures, labour and HOM complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality and complete as per Engineer directions. | 1.6 | 58.695 | Sqm |
|---|
| 8 | 8 | Providing, fabricatin, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6 x 44.45 mm thickness 3.18 mm section weight 2.404 kg/m, door shutters vertical section 44.62 x 44.45 mm thickness 3.18 mm, section weight 1.505 kg/m, top section 47.62x 44.45 mm thickness, 3.00 mm, section weight 1.426 kg/m bottom section 114.3x 44.45 thickness 3.18 mm, section weight 2.646 kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11 mm thickness 0.9mm section weight 0.124 kg/m; aluminium sections cut to length metered corners grinded, the shutters pivoted opening arrangements with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accesories, such as aluminium handle for full width or length, tower bolts, locks, pivots; PVC or rubber gasket with 5.5 m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formatio, and coated with greasy ,aterials for non adherence of mortars or any other stick materials; assembled frame fitted with the corner angles, stripes and fitted with screws, rawl plugs or teakwood gutties to RCC columns or masonry on sides, beams and flooring in bottom including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. using aluminium section powdered coated to a miminum of 60-70 microns with exterior durable pure polyester grade powder of approved quality and complete as per Engineer directions. | 1.7 | 4.305 | Sqm |
|---|
| 9 | 9 | Providing and fixing in position 10mm thick plaster of parris (Gypsum anhydrous) for ceiling up to a height of 5 m above floor level over aluminium strips 25mm/6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to a metal frames including cost of materials, labour, curing complete as per specifications and Engineer directions. | 1.8 | 27.25 | Sqm |
|---|