Low Voltage Current Transformer Having Ct Ratio 200/5, Applicable Standard-Gujarat

Western Railway-WR has published Low Voltage Current Transformer Having Ct Ratio 200/5, Applicable Standard. Submission Date for this Tender is 17-12-2020. Chemical Supply Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

26191407
Low Voltage Current Transformer Having Ct Ratio 200/5, Applicable Standard
Open Tender
Indian
Gujarat
17-12-2020

Tender Details

Supply Of , Low Voltage Current Transformer Having Ct Ratio 200/5, Applicable Standard: - Iec 61869-1&2 / Iec- 60044 -1, Bs 3938, Is 2705 -1,2&3. Case: - Unfilled Polycarbonate, Flame Retardant Grades Classified Ul94v-0. Connection: - Two Connection On Each Side- M4 Screws With Self Lifting Clamp Strap Assembly For Rishxmer Series And 1 Connection On Each Side M4 Screws With Self Lifting Clamp Strap For Rish Ctseries. Insulation Class-E (120%B0c Max) System Voltage: - 720V Maximum, Test Voltage: - 4 Kv, 50 Hz For 1 Min Operating Frequency: - 50Hz / 60 Hz, Rated Primary Rating: - 200 A, Rated Secondary Output: - 5A Standard (1Aon Request), Rated Burden: - 1.5 Va, Class Of Accuracy: - 0.5 For Accurate Measuring Of Kwh. Make- Rishbh, L&T, Siemens 1 For General Measurement 3 For Indicating Instruments # Ambient Temperature: - -25%B0c To +40%B0c # Storage Temperature: - -50%B0c%U2026+80%B0c # Thermal Short Circuit Current (Ith):- 60Xin For Bus Bar Type Ct. # Dynamic Short Circuit Current (Idyn):- 2.5Xith # Instrument Security Factor (Fs): - 2.5, 5, 10

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

0 1 2 3 4 5 6 7 8 9
0 S.No. PL Code\r(Group) Item Type\rGST(Y/N) Stock /\rNonStock Ordering Consider For\rEval Approving\rAgency Inspection\rAgency Currency\rAllowed Estimated\rRate
1 1 4202N01 Goods (Y) Non Stock --- Yes CONSIGNEE INR
2 Description :Low Voltage Current Transformer having CT Ratio 200/5, Applicable standard: - IEC 61869-1&2 / IEC- 60044 -1, BS 3938, IS 2705 -1,2&3.\rCase: - Unfilled polycarbonate, flame retardant grades classified UL94V-0. Connection: - Two connection on each side- M4 screws with self lifting clamp strap\rassembly for RishXmer series and 1 connection on each side M4 screws with self lifting clamp strap for Rish CTseries. Insulation class-E (120%B0C max)\rSystem voltage: - 720V maximum, Test voltage: - 4 KV, 50 Hz for 1 min Operating frequency: - 50Hz / 60 Hz, Rated primary rating: - 200 A, Rated secondary\routput: - 5A standard (1Aon request), Rated burden: - 1.5 VA, Class of accuracy: - 0.5 for accurate measuring of kWh. Make- RISHBH, L&T, SIEMENS 1 for\rgeneral measurement 3 for indicating instruments # Ambient temperature: - -25%B0C to +40%B0C # Storage temperature: - -50%B0C%u2026+80%B0C #\rThermal short circuit current (Ith):- 60xIn for Bus Bar type CT. # Dynamic short circuit current (Idyn):- 2.5xIth # Instrument security factor (FS): - 2.5, 5, 10
3 Consignee Sr.Section Engineer EL/POWER Sabarmati. Gujarat 4.00 Numbers