Construction Of Odisha State Beverages Corporation Ltd . ( Osbc ) Godown And Ancillary Building In I/E , Chhatrapur , Ganjam, Chhatrapur-Odisha

Orissa Industrial Infrastructure Development Corporation-IDCO has published Construction Of Odisha State Beverages Corporation Ltd . ( Osbc ) Godown And Ancillary Building In I/E , Chhatrapur , Ganjam. Submission Date for this Tender is 21-12-2020. Building Work Tenders in Chhatrapur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

26182188
Construction Of Odisha State Beverages Corporation Ltd . ( Osbc ) Godown And Ancillary Building In I/E , Chhatrapur , Ganjam
National Competitive Bid
Indian
Odisha
Chhatrapur
21-12-2020

Tender Details

Construction Of Odisha State Beverages Corporation Ltd . ( Osbc ) Godown And Ancillary Building In I/E , Chhatrapur , Ganjam

Key Value

Document Fees
INR 11800 /-
EMD
INR 1108000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of Odisha State Beverages Corporation Ltd. (OSBC)Godown & ancillary Building in I/E, Chhatrapur, Ganjam
Sl. No. Item Description Item Code / Make Quantity Units
1 1 CIVIL WORK. BI01010001010000000000000515BI0100001112
2 2 Earth work in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001113 3463.61 Cum
3 3 Earth work in excavation of foundation trenches in Stoney earth & Gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto required depth and depositing the excavated materials away from the work site with all lead and lift, including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001114 89.44 Cum
4 4 Earth work in excavation of foundation trenches in Hard rock (Granite) removed by chiseling including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift, including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete in all respect excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001115 89.44 Cum
5 5 Clearing grass and removal of rubbish up to adistance of 50 metres outside the periphery of the area complete in all respect excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001116
6 5.01 Land devlopment area BI01010001010000000000000515BI0100001117 11837.5 Sqm
7 6 Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete in all respect excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001118 2320.62 Cum
8 7 Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties of all Materials, cost of all Labour,Sundries, T&P required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. (Measurement will be taken on finished compacted section only.) BI01010001010000000000000515BI0100001119 42419.6 Cum
9 8 Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as  preconstructional anti- termite  treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation,  top surface of  plinth   filling, junction of walls and floors along with external  perimeter of the  building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. complete in all respect as per specification as directed by the Engineer -in -charge. BI01010001010000000000000515BI0100001120 3382.71 sqmt
10 8.01 a) Treatment to soil below raft: Before laying the rubble soling and pcc the compacted and leveled soil shall be treated at 5 litre / sq.m. BI01010001010000000000000515BI0100001121
11 8.02 b)Treatment to soil along the retaining wall:The soil coming in contact with the retaining wall shall be treated at 5 litre per sq. m. The treatment shall follow the backfilling as backfilling is done in stages of 30 cms but not to exceed a depth of 1metre. Rodding may be carried out to facilitate the treatment. BI01010001010000000000000515BI0100001122
12 8.03 c)Treatment to soil along the external perimeter of the building:The soil around the external perimeter of the building up to a depth of 30 cm shall be treated at 2.25 litres per linear metre. Rodding may be carried out to facilitate this treatment. BI01010001010000000000000515BI0100001123
13 8.04 d) Treatment of soil surrounding pipes, wastes and conduits:When pipes, wastes and conduits enter the soil inside the area of the foundation, the soil surrounding the point of entry must be loosened around each such pipe, waste or conduit for a distance of 15 cm and upto a depth of 7.5cm and loosened soil shall be treated with chemical emulsion. BI01010001010000000000000515BI0100001124
14 8.05 e)Spraying equipment:A pressure pump shall be used to carry out spraying operations to facilitate proper distribution of chemical in the soil. BI01010001010000000000000515BI0100001125
15 8.06 Note: All the Anti-termite treatment shall be executed through a recognised agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of 10( Ten ) years from the certified date of completion for the satisfactory performance of the entire Anti-termite treatment system. The Defect Liability Period of the Anti-termite treatment is Ten years.The contractor has to furnish bank guarantee amounting to Rs. 3,00,000/- which will be released after 10(Ten) years from the date of completion of the whole work. In case,the contactor fails to furnish the B.G.,equal amont i.e. Rs. 3,00,000/- will be kept withheld from the Security Deposit till the end of the Defect Liability Period. BI01010001010000000000000515BI0100001126
16 9 Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001127 756.72 Cum
17 10 Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001128 293.95 Cum
18 11 Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate 12mm nominal size) as levelling course in foundation and plinth etc. including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001129 40.74 Cum
19 12 Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001130 269.42 Cum
20 13 Fly Ash. brick masonry of size 23 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in foundation & plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect as per specification excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001131 430.48 Cum
21 14 Fly Ash. brick masonry of size 23 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect as per specification excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001132
22 14.01 Ground Floor BI01010001010000000000000515BI0100001133 950.93 Cum
23 14.02 First Floor BI01010001010000000000000515BI0100001134 50 Cum
24 14.03 Second Floor BI01010001010000000000000515BI0100001135 31.11 Cum
25 15 Half Brick work with Fly ash Bricks in superstructure having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1 cement: 4 sand) including watering and curing for the required period, imersing the bricks in warer before 6 hours of use, including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect as per specification excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001136
26 15.01 Ground Floor BI01010001010000000000000515BI0100001137 15.49 cum
27 15.02 First Floor BI01010001010000000000000515BI0100001138 25.98 cum
28 16 Laterite stone masonry in cement mortar of mix (1:6) with cement ,screened & washed sharp river sand for mortar use in Foundation & Plinth including splays cutting ,circular moulding and similar such types of works with all necessary projections, champering , corbelling, watering & curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect as per specification excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001139
29 16.01 Compound wall & gate BI01010001010000000000000515BI0100001140 1131.32 cum
30 17 Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works( i.e footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, Lofts, Railings etc. ) as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001141
31 17.01 Ground Floor BI01010001010000000000000515BI0100001142
32 17.02 Footing & pedestal BI01010001010000000000000515BI0100001143 351.22 Cum
33 17.03 Column up to plinth level BI01010001010000000000000515BI0100001144 223.84 Cum
34 17.04 Tie Beam BI01010001010000000000000515BI0100001145 38.62 Cum
35 17.05 Plinth Beam BI01010001010000000000000515BI0100001146 334.38 Cum
36 17.06 Column above pl lvl BI01010001010000000000000515BI0100001147 124.21 Cum
37 17.07 Lintel BI01010001010000000000000515BI0100001148 40.18 Cum
38 17.08 Roof beam BI01010001010000000000000515BI0100001149 139.29 Cum
39 17.09 Roof slab BI01010001010000000000000515BI0100001150 69.29 Cum
40 17.1 Stair case BI01010001010000000000000515BI0100001151 1.66 Cum
41 17.11 chajja BI01010001010000000000000515BI0100001152 12.69 sqm
42 17.12 First Floor BI01010001010000000000000515BI0100001153
43 17.13 Lintel BI01010001010000000000000515BI0100001154 2.36 Cum
44 17.14 Column in S.S BI01010001010000000000000515BI0100001155 11.04 Cum
45 17.15 Roof beam BI01010001010000000000000515BI0100001156 20.94 Cum
46 17.16 Roof slab BI01010001010000000000000515BI0100001157 27.05 Cum
47 17.17 Stair case BI01010001010000000000000515BI0100001158 1.66 Cum
48 17.18 chajja BI01010001010000000000000515BI0100001159 12.69 sqm
49 17.19 Second Floor BI01010001010000000000000515BI0100001160
50 17.2 Lintel BI01010001010000000000000515BI0100001161 0.26 CUM
51 17.21 Column in S.S BI01010001010000000000000515BI0100001162 2.23 cum
52 17.22 Roof beam BI01010001010000000000000515BI0100001163 2.47 cum
53 17.23 Roof slab BI01010001010000000000000515BI0100001164 4.14 cum
54 17.24 Stair case BI01010001010000000000000515BI0100001165 1.66 cum
55 18 Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-20 Grade in all type of Concrete works( i.e footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, Lofts, Railings etc. ) as per approved designs and drawings having a minimum compressive strength ( in work test) 20 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001166
56 18.01 Drainage BI01010001010000000000000515BI0100001167
57 18.02 Drain Bottom raft BI01010001010000000000000515BI0100001168 67.3 Cum
58 18.03 Drain wall BI01010001010000000000000515BI0100001169 80.7 Cum
59 18.04 slab BI01010001010000000000000515BI0100001170 56.5 Cum
60 18.05 Internal Road BI01010001010000000000000515BI0100001171
61 18.06 plain cement concrete M20 as levelling course in kerb stone. BI01010001010000000000000515BI0100001172 64.96 Cum
62 19 Providing & fixing Thermo mechanically treated bars (Fe-500 ) Reinforcement bars of approved make for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyance of reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour, loading, unloading, labour cess, T&P, etc. required for the work complete for the work in all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) BI01010001010000000000000515BI0100001173
63 19.01 Ground Floor BI01010001010000000000000515BI0100001174 2686.96 Qntl
64 19.02 First Floor BI01010001010000000000000515BI0100001175 113.59 Qntl
65 19.03 Second Floor BI01010001010000000000000515BI0100001176 18.77 Qntl
66 20 16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete in all respect as per specification excluding GST as directed by the Engineer- in -charge. BI01010001010000000000000515BI0100001177
67 20.01 Ground Floor BI01010001010000000000000515BI0100001178 5862.01 Sqm
68 20.02 First Floor BI01010001010000000000000515BI0100001179 216.82 Sqm
69 20.03 Second Floor BI01010001010000000000000515BI0100001180 108.06 Sqm
70 21 12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete in all respectas per specification excluding GST as directed by the Engineer- in- charge. BI01010001010000000000000515BI0100001181
71 21.01 Ground Floor BI01010001010000000000000515BI0100001182 4781.8 Sqm
72 21.02 First Floor BI01010001010000000000000515BI0100001183 565.77 Sqm
73 21.03 Second Floor BI01010001010000000000000515BI0100001184 90.31 Sqm
74 22 6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respectas per specification excluding GST as directed by the Engineer- in- charge BI01010001010000000000000515BI0100001185
75 22.01 Ground Floor BI01010001010000000000000515BI0100001186 721.77 Sqm
76 22.02 First Floor BI01010001010000000000000515BI0100001187 216.54 Sqm
77 22.03 Second Floor BI01010001010000000000000515BI0100001188 33.18 Sqm
78 23 12mm cement plaster on external RCC/brick surfaces in cement mortar 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement punningincluding cost, conveyance, loading, unloading, royalties ,stacking of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respectas per specification excluding GST as directed by the Engineer- in- charge BI01010001010000000000000515BI0100001189
79 23.01 Drainage BI01010001010000000000000515BI0100001190 795.3 Sqm
80 24 Providing and fixing factory made WPC (Wood Polymer Composite) door and window frames made of virgin PVC,generally structured with solid extrusion section of density not less than 950kg/cum having size 127mmx63.25mm an overall dimension below (tolerance +/- 1mm), corners of door and window frames are to be jointed with stainless steel screws, and fixed in position with hold fast lugs or dash fasteners of 8mm dia and 25mm length including cost of hold fast lugs / fasteners cost, conveyance, labour charges etc. as per the direction of Engineer-in-Charge. (Excluding GST). BI01010001010000000000000515BI0100001191
81 24.01 Ground Floor BI01010001010000000000000515BI0100001192 89.52 Rmt
82 24.02 First Floor BI01010001010000000000000515BI0100001193 26 Rmt
83 24.03 Second Floor BI01010001010000000000000515BI0100001194 10.4 Rmt
84 25 Supplying, fitting and fixing of 32mm thick factory made (both side 1 mm thick lamination) ) flush door shutters with as per IS- 2202/92 with solid core block board from seasoned and treated 2nd class hard wood , Battern, bonded with phenol formal dehide synthetic resign pressed over suitable adhesive including providing stainless steel hinges, locking arrengement and other fittings & fixtures required for the work complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001195
85 25.01 Ground Floor BI01010001010000000000000515BI0100001196 39.68 Sqm
86 25.02 First Floor BI01010001010000000000000515BI0100001197 11.38 Sqm
87 25.03 Second Floor BI01010001010000000000000515BI0100001198 4.55 Sqm
88 26 Factory made FRP( Altematly called GRP) door frame of size 75mm x 100mm fabricated using E - glass chopped strand mat (CSM) U.V stabilised inopathalic Gel coat and impregnated with inopathalic resin The thickness of the GRP skins shall not be less then 2.0 mm . The door frame consists of four segments which are provided with plug in socket arrrangement in-situ-in mould. The segments are plugged in and are joined together by means of srew. The GRP frame shall be provided with wooden reinforcement on six locations for high srew holding capacity for fixing metalic hold fast and shall be consolidated by filling with medium density foam / plaster of paris with fibre reinforcement , six number of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the finish of door frame shall conform to RV-TIFAC composites Design centre's standards and specifications . The finish of door frame will be plain colour white /Ivory/Beige/Light grey / Golden brown / Mahogany/ Teak wood /sand stone Champagne/Pastel blue or any other colour using high quality pigment complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001199
89 26.01 Ground Floor BI01010001010000000000000515BI0100001200 50.61 Rmt
90 26.02 First Floor BI01010001010000000000000515BI0100001201 30.49 Rmt
91 27 Factory made GIRID FRP or called GRP sandwich composite door shutter of 32mm thick laminated with two GRP skin with good grain finish fabricated using UV stabilised isoppthalic gel coat and one layer of 450 gsm E-glass chopped strand mat (CSM) impregnated with ortopathilic resin The thickness of the skins shall not be less than 1.50mm . Expanded polysryne ( EPS) structural foam panel of 29 mm tickness and a density of 20kg/cu.mts shall be used as core material wooden reinforcements made of sesasoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinforcements for fitting the metal fittings such as lower bolts ,aldrops, handles etc. shall be provided . A structural adhesive compatible with (EPS)foam shall be used for bending the core material. the sal wood reinforcements and the skin The material and process for manufactuing te door shutter shall conform to RV -TIFAC components design centre's standards and specification and the door shutters tested in conformation to IS 4020-1998. The Finish of door shutter will be plain colour . etc. complete in all respect excluding GST as per specification and direction of the Engineer in charge. BI01010001010000000000000515BI0100001202
92 27.01 Ground Floor BI01010001010000000000000515BI0100001203 16.91 Sqm
93 27.02 First Floor BI01010001010000000000000515BI0100001204 10.41 Sqm
94 28 Providing & fixing of side hung door of approved make to be fabricated from roll formed sections made of pre -painted steel (base steel as per IS-513 of 0.60 mm thick "D" qualiyu, galvanised as per IS-277 with zinc of 120 gm/sqm)with total coated thickness of 0.55 mm slide guide section should be made of o.5 mm stainless steel of 430 grade with paint specification being with primer of 5-7 microns thick & finished paint with polyster paint(Black/Pearlwhite/Chocolate brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns & sections for external frame bottom & top should be of 79x45 mm external frame sides should be of 69x24 mm, guide for top & bottom should be of 69x26 mm ( stainless steel). section for shutter should be of 26x30 mm, sash bar should be of 23x57 mm .Accessories/gaskets are to be used as per the manufacturer's supply & specifiction like gasket will be made of EPDM . All corner brackets for internal & external are to be made of glass filled nylon. The sections are to be cut to length, joined & assembled by means of corner bracket &frames are fixed to the concrete/ masonry walls by means of self expanding screws &board to be of 9mm pre-laminated / 6mm glass etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001205
95 28.01 Ground Floor BI01010001010000000000000515BI0100001206 32.02 Sqm
96 28.02 First Floor BI01010001010000000000000515BI0100001207 2.28 Sqm
97 29 Providing and laying Industrial Vitrified floor tiles 300x300 mm of 10mm thick of approved make confirming to I.S.15622 or equivalent laid on 20mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST as per specification as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) BI01010001010000000000000515BI0100001208 2507.52 Sqm
98 30 Supplying, fitting & fixing of Industrial Vertified tiles in dadoes, skirting and risers having thickness of 8mm to 10mm conforming to IS 13756 of 300mmx300mm of approved quality in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the Industrial vitrified tile if required watering and curing for 21 days,including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) BI01010001010000000000000515BI0100001209 132.06 Sqm
99 31 Providing ,Fitting and Fixing minimum 8 m.m to 10m.m thick Vitrified Tile in flooring using Vitrified Tile of approved quality, colour and size(600 m.m x 600 m.m coloured printed series homogeneous) in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work ,Watering,Curing for required days including cleaning the flooring space manually etc. complete in all respect excluding GST as directed by the Engineer-in-charge. Note - Sample of tiles shall be approved before procurement and use.) BI01010001010000000000000515BI0100001210
100 31.01 Ground Floor BI01010001010000000000000515BI0100001211 643.37 Sqm
101 31.02 First Floor BI01010001010000000000000515BI0100001212 247.58 Sqm
102 31.03 Second Floor BI01010001010000000000000515BI0100001213 19.98 Sqm
103 32 Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring in toilets using special plain / printed series anti-skid ceramic floor tile of premium grade (having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm or 400 mm x 400 mm ) confirming to I.S 13755 of approved quility and shade on 20mm thick ded of cement morter of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the anti-skid ceramic floor tiles with neat white cement slurry, mixed with required (tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the anti-skid ceramic floor tiles if required including cost, conveyance, loading, unloading, stacking, royalties of all material, cost of all labour , sundries, T&P required for the work , watering,complete in all respect as per specification excluding GST aas per specification as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) BI01010001010000000000000515BI0100001214
104 32.01 Ground Floor BI01010001010000000000000515BI0100001215 44.23 Sqm
105 32.02 First Floor BI01010001010000000000000515BI0100001216 24.72 Sqm
106 33 Providing & Fixing tiles of size 20 x 30cm glazed ceramic wall tiles of premium grade of approved quality and shade having thickness 8mm to 10mm confirming to IS 13755 in dados skirting and risers of steps on 12mm thick cement plaster (1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc including filling the joints with neat white cement slurry mixed with pigments to match the shade of the tiles including cost, conveyance,loading,unloading,stacking, royalities of all materials, cost of all labour,T&P, sundries, watering and curing for the required period for the work complete in all respect excluding GST as per specification as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) BI01010001010000000000000515BI0100001217
107 33.01 Ground Floor BI01010001010000000000000515BI0100001218 177.23 Sqm
108 33.02 First Floor BI01010001010000000000000515BI0100001219 94.8 Sqm
109 34 Supplying, fitting and fixing M.S Rolling Shutter on Entrance Verandah of approved design to be fixed in RCC columns / Brick works shall be made of MS angles and MS square bars and MS plates of required sizes with necessary welded clamps fixed in position to proper plumb including a coat of primer of approved quality metallic primer, making holes in walls or RCC Columns and grouting clamps with c.c(1:2:4) with 12mm size black hard crusher broken granite chips, making good to damages of walls/ RCC columns including cost of all materials , transportation, all labour, sundries, T&P etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge.( Weight to be measured before fixing) BI01010001010000000000000515BI0100001220 208.18 sqmt
110 35 Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge. ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) BI01010001010000000000000515BI0100001221
111 35.01 Ground Floor BI01010001010000000000000515BI0100001222 5141.48 Kg.
112 35.02 First Floor BI01010001010000000000000515BI0100001223 344.5 Kg.
113 35.03 Second Floor BI01010001010000000000000515BI0100001224 146.25 Kg.
114 36 Supplying, fitting and fixing Aluminium frame with glass louver's on window including cost, conveyance, loading, unloading of all materials, cost of all labour, T&P etc. complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001225 27.05 Sqm
115 37 Supplying Fitting, fixing up fully glazed aluminium framed window (sliding type) made up aluminium section 9778 as window frame, section 4095, 4096 and 9777, 3994 as shutter frame with 5mm black glass as panel fitted with rubber beading including locking arrangement including all fittings including cost, conveyance, loading, unloading of all materials, cost of all labour, T&P etc. complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001226
116 37.01 Ground Floor BI01010001010000000000000515BI0100001227 71.21 Sqm
117 37.02 First Floor BI01010001010000000000000515BI0100001228 32.05 Sqm
118 37.03 Second Floor BI01010001010000000000000515BI0100001229 5.44 Sqm
119 38 Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001230
120 38.01 Ground Floor BI01010001010000000000000515BI0100001231 11365.6 Sqm
121 38.02 First Floor BI01010001010000000000000515BI0100001232 999.13 Sqm
122 38.03 Second Floor BI01010001010000000000000515BI0100001233 231.55 Sqm
123 39 Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat paint of approved shade and quality of approved design after cleaning by watering & removing the dirts etc. to the surface to be painted in all floor & at all heights including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001234
124 39.01 Ground Floor BI01010001010000000000000515BI0100001235 5782.48 Sqm
125 39.02 First Floor BI01010001010000000000000515BI0100001236 216.82 Sqm
126 39.03 Second Floor BI01010001010000000000000515BI0100001237 108.06 Sqm
127 40 Providing and applying white cement based putty of average thickness 1 mm of approved make and finished smooth and even surface to receive painting including cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001238
128 40.01 Ground Floor BI01010001010000000000000515BI0100001239 7811.4 Sqm
129 40.02 First Floor BI01010001010000000000000515BI0100001240 782.32 Sqm
130 40.03 Second Floor BI01010001010000000000000515BI0100001241 123.49 Sqm
131 41 Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion paint of approved brand, shade and manufacture including on existing putty surface, existing one coat of cement primer, two coats of acrylic emulsion paint to give an even shade on walls and ceiling, including providing necessary scaffolding, cleaning the surface with water to remove all coating dust etc. including cost of all materials, labour, T&P, etc. complete as per specification. complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001242
132 41.01 Ground Floor BI01010001010000000000000515BI0100001243 6494.94 Sqm
133 41.02 First Floor BI01010001010000000000000515BI0100001244 782.32 Sqm
134 41.03 Second Floor BI01010001010000000000000515BI0100001245 123.49 Sqm
135 42 Providing and painting two coats with synthetic enamel paint on Iron work over a coat of Red Oxide Primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect excluding GST as per specification as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001246
136 42.01 Ground Floor BI01010001010000000000000515BI0100001247 2773.75 Sqm
137 42.02 First Floor BI01010001010000000000000515BI0100001248 70.44 Sqm
138 42.03 Second Floor BI01010001010000000000000515BI0100001249 11.96 Sqm
139 43 Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade including cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001250 931.96 Sqm
140 44 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses/girders etc.,( as per drawing) including cutting,fabricating, hoisting, fixing in position , applying two coat of enmel paint over a coat of priming of approved steel primer and of approved make, including welding and bolting with special shaped washers etc. including cost, coveyance, erection ,loading and unloading of all materials, cost of all labour, sundries, T&P, etc. required for the work complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001251 81695.2 Kg.
141 45 Providing fitting and fixing of Aluminium sheets( High Crest profil) for roofing works at all heights using 1.00mm(Weight=3.88 Kg/m2) aluminium Sheets of approved make confirmming to HS 7606 including cutting , bending , and placing in position making holes all fabrications and errections and Fixing with purlins by self driven Cyclone washer & screw as per specification of manufacturer ensuring water proof and Fixing wind ties, Cost and conveyance of all materials labours ,T&P, Safety Belts & Safety Nylon Nets for workers are to be provided for protection from accidental falling during working at heights & other misc expenditures. etc. required for the work and complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001252 3290.32 Sqm
142 46 Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials , cost of all labour, T&P etc. required for the complete in all respect excluding GST as per specification as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001253
143 46.01 Ground Floor BI01010001010000000000000515BI0100001254 67.99 Kg.
144 46.02 First Floor BI01010001010000000000000515BI0100001255 67.99 Kg.
145 46.03 Second Floor BI01010001010000000000000515BI0100001256 67.99 Kg.
146 47 Providing and fixing of 16 mm thick mineral fibre false ceiling tiles of approved make at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings etc. complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001257 195.17 Sqm
147 48 Providing suspended of gypsum false ceiling approved make which includes G.I perimeter channels of size 0.55mm thick (having one flange of 20 mm and another flange of 30 mm and a web of 27mm) along with perimeter of ceiing, screw fixed to brick wall / partition with the help of nylo sleeves and screws at 610mm centres. Then suspending G.I intermidiate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at 1220 mm centre with ceiling angle of width 25mm X 10mm X 0.55mm thick fixed to soffit with G.I cleat and steel expantion fastness. Ceiling section of .55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 105mm are then fixed to the intermidiate channel with the help of connecting clip and in direction perpendicular to the intermidiate channel at 457mm centres. 12.5 mm tappered edge Gyp. Board ( conformining to IS 2095-1982) is then screw fixed to ceiling section with 25 mm drywall screws at 230 mm centres. screw fixing is done mechanically either with screw driver drilling machine with suitable attachment.etc.complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001258 97.58 Sqm
148 49 Loosening levelling & compacting original ground suppourting embankment to facilitate a placement of 1st layer of embankment up to a depth of 150mm mixed with water at OMC & then and then compacted by rolling as per Clause 300.20 for embankment construction as per Clause No- 305.3.4 of MoRTH specifiction etc.complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001259 917.34 Cum
149 50 Providing & laying granular sub base with close graded Grading-III materials as per table 4000-01. Spreading in uniform layers with mortar grader on prepared surface mixing by mix in place method with rotavator at OMC & compacting with VRR to achieve desired density as per Clause 401 of MORT& H specification of road & bridge work etc. complete in all respect excluding GST as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001260 1527.73 Cum
150 51 Supplying and laying of factory made hydraulically pressed and mechanically compacted pre-cast interlocking PAVER blocks of M-35grade, 80mm thick over 50mm thick compacted bed of sand,compacting and proper laying of paver blocks in to the sand bedding layer through vibrator compaction by using plate vibrator,filling the joints with sand and finishing the surface including cutting of blocks at the edges with all labour and materials cost etc.work complete in all respect(excluding GST) as per specification as directed Engineer-in-charge. BI01010001010000000000000515BI0100001261 7536.25 Sqm
151 52 ELECTRICAL PORTION BI01010001010000000000000515BI0100001262
152 53 Internal Wiring Items) BI01010001010000000000000515BI0100001263
153 54 wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC rigid conduit with 6Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size, MS box with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. BI01010001010000000000000515BI0100001264
154 54.01 Single light controlled by one 6A switch or first point GROUP-A BI01010001010000000000000515BI0100001265 74 Nos
155 54.02 Single light controlled by one 6A switch or first point GROUP-B BI01010001010000000000000515BI0100001266 94 Nos
156 54.03 Single light controlled by one 6A switch or first point GROUP-C BI01010001010000000000000515BI0100001267 79 Nos
157 55 subsequent point of group controlWiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. BI01010001010000000000000515BI0100001268 178 Nos
158 56 6A Plug on the same board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved BI01010001010000000000000515BI0100001269 67 Nos
159 57 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) cover,modular board & other required accessories of ISI marked as approved BI01010001010000000000000515BI0100001270 115 Nos
160 58 2x6A Plug on the separate board For computer/UPS/other power point or TV point & other use for Data center/go down area with complete fitting by 02 nos of 6A switch & socket(modular type) cover,modular board & other required accessories of ISI marked as approved BI01010001010000000000000515BI0100001271 21 Nos
161 59 Supplying and fixing 15/16A modular socket with 15/16A Switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001272 58 Nos
162 60 Wiring for circuits and submain with following number & sizes of FRLSH PVC insulated 1100 volt grade multistranded copper conductor wire run inside nonmetallic PVC rigid conduit recessed in ceiling/ column/ walls of building including supply of all materials such as wires, conduit, junction box & pull box / duly clamped to wall /ceiling or cable tray as suitable etc complete with making good the damages caused as required and as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001273
163 60.01 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001274 294 Mtr
164 60.02 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001275 770 Mtr
165 60.03 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001276 525 Mtr
166 60.04 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 6 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001277 261 Mtr
167 60.05 2 nos single core 10 sq. mm copper wire for phase and neutral and 01 nos of single core 6 sq. mm copper wire for earth continuity conductor. BI01010001010000000000000515BI0100001278 8 Mtr
168 60.06 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001279 25 Mtr
169 60.07 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001280 196 Mtr
170 60.08 4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor. BI01010001010000000000000515BI0100001281 20 Mtr
171 61 Supply, delivery, installation & testing of AC boards consisting of 1 No 20-A DP Modular switch with indicator and 1 No 16A Moular socket in indivisual Modular G.I Box making good the damages caused complete as required and as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001282 10 Nos
172 62 Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens make BI01010001010000000000000515BI0100001283 35 Nos
173 63 Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens make BI01010001010000000000000515BI0100001284 8 Nos
174 64 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. MAKE Polycab/ AKG/precission BI01010001010000000000000515BI0100001285
175 64.01 20 MM BI01010001010000000000000515BI0100001286 100 Mtr
176 64.02 25 MM BI01010001010000000000000515BI0100001287 120 Mtr
177 65 Supply and fixing modular type indicator on the existing switch box/cover of Anchor make. BI01010001010000000000000515BI0100001288 28 Nos
178 66 Supplying and installation of AC starter Modular type,L&T make or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including moudlar cover. BI01010001010000000000000515BI0100001289 35 Nos
179 67 Light fitting & Fixture BI01010001010000000000000515BI0100001290
180 68 Supplying, installation, of FRP AIR roofing turbo ventilator SYSTEM with fan of heavy duty with louvers (Branded make make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing roof top , including fixing & conntection. BI01010001010000000000000515BI0100001291 28 Nos.
181 69 Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (Havells make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection. BI01010001010000000000000515BI0100001292 14 Nos.
182 70 Supply delivery, installation, testing & commissioning of 450 mm (18") size Heavy Duty Exhaust Fan, 1400 RPM similar to Havells or equivalent complete etc.as required..(For both in and out air exhaust system) BI01010001010000000000000515BI0100001293 28 Nos.
183 71 Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan of Havells Pacer Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) BI01010001010000000000000515BI0100001294 43 Nos.
184 72 Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of Havells Pacer Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) BI01010001010000000000000515BI0100001295 33 Nos.
185 73 Supplying and fixing of 40 W LED Optima ,WIPRO LL24-541-XXX-65-XX , WIPRO make or equivalent and any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required. BI01010001010000000000000515BI0100001296 14 Nos.
186 74 Supplying and fixing of 60 W LED High bay Light of PAC Make Model no. HB11-LHB60 or equivalent and any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required. BI01010001010000000000000515BI0100001297 49 Nos.
187 75 Supplying and fixing of 18 Watt LED round Surface Fittings CAT No. LD80-171-XXX-60-SM , WIPRO make or equivalent and any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required. BI01010001010000000000000515BI0100001298 22 Nos.
188 76 Supplying and fixing of 18 Watt LED round Recessed Fittings CAT No. LD80-171-XXX-60-XX****** , WIPRO make or equivalent and any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required. BI01010001010000000000000515BI0100001299 40 Nos.
189 77 Supplying and fixing of 20 Watt LED Tube light Fittings CAT No. CAT No. LL20-281-XXX-65AL1** , WIPRO make or equivalent and any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required. BI01010001010000000000000515BI0100001300 262 Nos.
190 78 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 2x10 cm . BI01010001010000000000000515BI0100001301 62 Nos.
191 79 Branch Distribution Boards BI01010001010000000000000515BI0100001302
192 80 Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar make, or any other equivallent A catagories reputed make ISI marked as approved BI01010001010000000000000515BI0100001303
193 80.01 6 way, Double Door TPN DB (FOR LIGHT,POWER) BI01010001010000000000000515BI0100001304 5 Nos
194 80.02 4 way, Double Door TPN DB (FOR POWER) BI01010001010000000000000515BI0100001305 7 Nos
195 80.03 12 way, Double Door SPN DB (FOR LIGHT ) BI01010001010000000000000515BI0100001306 14 Nos
196 81 Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Legrand/L&T/Siemens make or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections. BI01010001010000000000000515BI0100001307 398 Nos
197 82 Supplying and fixing 63 Amps rating, 4P, 415 volts, ISOLATOR any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required. BI01010001010000000000000515BI0100001308 1 Nos
198 83 Supplying and fixing 40 Amps rating, 4P, 415 volts, MCB ISOLATOR any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required. BI01010001010000000000000515BI0100001309 9 Nos
199 84 Supplying and fixing 25Amps DP 240 volts, RCCB,30mA any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections. BI01010001010000000000000515BI0100001310 12 Nos
200 85 Supplying and fixing 40Amps DP 240 volts, RCCB,30mA make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections. BI01010001010000000000000515BI0100001311 2 Nos
201 86 Supplying and fixing 40 4P Amps RCCB 415 volts, RCCB,30mA make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections. BI01010001010000000000000515BI0100001312 2 Nos
202 87 Earthing BI01010001010000000000000515BI0100001313
203 88 Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required. BI01010001010000000000000515BI0100001314 4 Nos
204 89 Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 4.5 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001315 8 Nos
205 90 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required. BI01010001010000000000000515BI0100001316 175 Mtr
206 91 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. BI01010001010000000000000515BI0100001317 100 Mtr
207 92 Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required. BI01010001010000000000000515BI0100001318 55 Mtr
208 93 Distribution Boards BI01010001010000000000000515BI0100001319
209 94 Supply, delivery, installation, testing & commissioning of L.T. indoor floor /wall mounted type distribution boards made out of 2mm thick CR sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged door and compartmental arrangement for each equipment & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001320
210 94.01 MDB- GODOWN BI01010001010000000000000515BI0100001321
211 94.02 Incomer:1 250A 4P MCCB(36 KA) with adjustable thermal setting+NL BI01010001010000000000000515BI0100001322
212 94.03 1 no. 100A 4P onload change over switch BI01010001010000000000000515BI0100001323
213 94.04 Bus bar: 4 nos. 250A Busbar duly sleeved BI01010001010000000000000515BI0100001324
214 94.05 Outgoing: 2 Nos 125A 3P MCCB with adjustable thermal setting BI01010001010000000000000515BI0100001325
215 94.06 9 Nos 40A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001326
216 94.07 2 Nos 32A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001327
217 94.08 9 Nos 32A 2P MCB 'C' (1okA) BI01010001010000000000000515BI0100001328
218 94.09 04 nos 40kA SP SPD with 32A SP MCB. BI01010001010000000000000515BI0100001329
219 94.1 Instruments: 2 set.LED type phase indicating lamps with control fuses BI01010001010000000000000515BI0100001330
220 94.11 1 no.250/5A CT operated Digital ammeter BI01010001010000000000000515BI0100001331
221 94.12 2nos.0-500V Digital voltmeter BI01010001010000000000000515BI0100001332
222 94.13 Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. BI01010001010000000000000515BI0100001333 1 Set
223 94.14 MDB- OFFICE BI01010001010000000000000515BI0100001334
224 94.15 Incomer:1 125A 4P MCCB(36 KA) with adjustable thermal setting+NL BI01010001010000000000000515BI0100001335
225 94.16 1 no. 63A 4P onload change over switch BI01010001010000000000000515BI0100001336
226 94.17 Bus bar: 4 nos. 150A Busbar duly sleeved BI01010001010000000000000515BI0100001337
227 94.18 3 Nos 63A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001338
228 94.19 2 Nos 40A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001339
229 94.2 3 Nos 32A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001340
230 94.21 2 Nos 40A 2P MCB 'C' (10kA) BI01010001010000000000000515BI0100001341
231 94.22 6 Nos 6-32A SP MCB 'C' (10kA) BI01010001010000000000000515BI0100001342
232 94.23 04 nos 40kA SP SPD with 32A SP MCB. BI01010001010000000000000515BI0100001343
233 94.24 Instruments: 2 set.LED type phase indicating lamps with control fuses BI01010001010000000000000515BI0100001344
234 94.25 1 no.125/5A CT operated Digital ammeter BI01010001010000000000000515BI0100001345
235 94.26 2nos.0-500V Digital voltmeter BI01010001010000000000000515BI0100001346
236 94.27 Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. BI01010001010000000000000515BI0100001347 1 Set
237 94.28 MDB- CANTEEN BI01010001010000000000000515BI0100001348
238 94.29 Incomer:1 125A 4P MCCB(36 KA) with adjustable thermal setting+NL BI01010001010000000000000515BI0100001349
239 94.3 1 no. 63A 4P onload change over switch BI01010001010000000000000515BI0100001350
240 94.31 Bus bar: 4 nos. 150A Busbar duly sleeved BI01010001010000000000000515BI0100001351
241 94.32 1 No 63A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001352
242 94.33 2 Nos 40A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001353
243 94.34 4 Nos 32A 4P MCB.'C' (10kA) BI01010001010000000000000515BI0100001354
244 94.35 5 Nos 32A 2P MCB 'C' (10kA) BI01010001010000000000000515BI0100001355
245 94.36 6 Nos 6-32A SP MCB 'C' (10kA) BI01010001010000000000000515BI0100001356
246 94.37 04 nos 40kA SP SPD with 32A SP MCB. BI01010001010000000000000515BI0100001357
247 94.38 Instruments: 2 set.LED type phase indicating lamps with control fuses BI01010001010000000000000515BI0100001358
248 94.39 1 no.125/5A CT operated Digital ammeter BI01010001010000000000000515BI0100001359
249 94.4 2nos.0-500V Digital voltmeter BI01010001010000000000000515BI0100001360
250 94.41 Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. BI01010001010000000000000515BI0100001361 1 Set
251 94.42 DB- UPS BI01010001010000000000000515BI0100001362
252 94.43 Incomer:1 No. 40A DP MCB.'C' (10kA) BI01010001010000000000000515BI0100001363
253 94.44 Bus bar: Busbar duly sleeved BI01010001010000000000000515BI0100001364
254 94.45 Outgoing: 4 Nos 25A 2P MCB 'C' (10kA) BI01010001010000000000000515BI0100001365
255 94.46 Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. BI01010001010000000000000515BI0100001366 2 Set
256 95 Cable and HDPE Pipe BI01010001010000000000000515BI0100001367
257 96 Supplying, laying & testing of following size of PVC insulated XLPE shethed / strip armoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001368
258 96.01 3core x 1.5 sq mm copper unarmoured cable. BI01010001010000000000000515BI0100001369 320 Mtr.
259 96.02 4 core x 16 sq mm Aluminium armoured Cable. BI01010001010000000000000515BI0100001370 70 Mtr.
260 96.03 Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable. BI01010001010000000000000515BI0100001371
261 96.04 4 core x 16 sq mm Aluminium armoured Cable. BI01010001010000000000000515BI0100001372 2 Nos
262 97 Providing and laying of fallowing dia HDPE pipe (medium class) in ground complete with HDPE fitting incl. trenching(75 mm depth)and refilling. BI01010001010000000000000515BI0100001373
263 97.01 110 mm Dia, PN-6, PE-80, HDPE pipe BI01010001010000000000000515BI0100001374 40 mtrs
264 97.02 63 mm Dia, PN-6, PE-80, HDPE pipe BI01010001010000000000000515BI0100001375 80 mtrs
265 98 Supply of materials, Fixing of G.I perforated cable tray along with hanging arrangements & supports fabrication complete. For following sizes. BI01010001010000000000000515BI0100001376
266 98.01 100x50x50x1.6mm thick. BI01010001010000000000000515BI0100001377 320 Mtr
267 98.02 300x50x50x1.6 mm thick. BI01010001010000000000000515BI0100001378 40 Mtr
268 99 5 KVA UPS SYSTEM BI01010001010000000000000515BI0100001379
269 100 Supply ,installation ,testing & commissioning of 5KVA single phase ON LINE UPS system with 12V 42AH SMF Battery ,IGBT based inverter system,protection for fault by OL,UV,EF,GF,OC of (AVO make or equivalent) including supply of rack inverter stand with sufficient backup upto 60 minutes with all required accessories to complete the job including all connection. BI01010001010000000000000515BI0100001380 2 Set
270 101 TV, Data Networking, Telephone and CCTV BI01010001010000000000000515BI0100001381
271 102 Supplying and laying of co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. BI01010001010000000000000515BI0100001382 40 Mtr
272 103 Supply of Material and installation of TV socket outlet. make Legrand Mylinc model or equivalent. BI01010001010000000000000515BI0100001383 1 Nos
273 104 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001384 1800 Mtr.
274 105 Supply & Installation of 24 port Cat 6 19" Patch Panel loaded with Jack. Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001385 4 Each
275 106 Supply, Installation Cat6 Information outlet for Data. Loaded shutter. RJ45 Information outlet, Face Plate and PVC Back Box Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001386
276 106.01 a) Dual BI01010001010000000000000515BI0100001387 25 Each
277 107 Supply, Installation, testing and commissioning of CAT6 Patch Cord , Minimum length of 1m, and maximum length of 5m. Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001388
278 107.01 a) 1Mtr. BI01010001010000000000000515BI0100001389 50 Each
279 107.02 b) 2Mtr. BI01010001010000000000000515BI0100001390 25 Each
280 108 Supply & Laying of 6 Core 9/125um Single Mode Optical Fiber Outdoor Cable Armored in the existing surface/ recessed Steel/ PVC conduit as required. Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001391 100 Mtr.
281 109 Supply & Installation of 6 Port Rack Mount SC SM LIU loaded with all required accessories (Adapter, Splice Tray, Pigtail, Etc..) Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001392 2 Each
282 110 Supply & Installation of SM Duplex Fiber Optics Patch cord 3 Mtrs. Make: D-Link / Molex / Tyco BI01010001010000000000000515BI0100001393 4 Each
283 111 Supply and Installation of following rack with standard accessories like PDU, Fan, Cable Manager etc as required. Make: D-Link / TATA /APW BI01010001010000000000000515BI0100001394
284 111.01 a) 15U Wall mounted BI01010001010000000000000515BI0100001395 2 Each
285 112 Supply and Installation of 24 Ports 10/100/1000Mbps + 4 10G Ports L2 Managed Switch etc as required. Make: D-Link / CISCO / Juniper BI01010001010000000000000515BI0100001396 2 Each
286 113 Supply and Installation of 24-Port 10/100/1000Mbps + 2-Port Combo 1000BASE-T/SFP PoE 370Watt Surveillance Switch etc as required. Make: D-Link / CISCO / Juniper BI01010001010000000000000515BI0100001397 2 Each
287 114 Supply and Installation of 1-Port Single Mode Transceiver SFP Module etc as required. Make: D-Link / CISCO / Juniper BI01010001010000000000000515BI0100001398 4 Each
288 115 Supply and Installation of 2MP IR Dome Camera (2.8mm Lens), 1/2.8” SONY - CMOS, 2MP, 0Lux with IR LED ON, Horizontal Field of View: 113 degrees, IR Range of up to 30 meters, Video Analytics: Trip Wire, Intrusion Detection and Motion Detection, H.265/H.264/MJPEG Video Compression, PoE Support, NAS Storage, SD Card(512GB) Support, Quad Stream Support, True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB, IK10, IP66, BIS, CE, FCC and RoHS Make- Matrix / Samsung / Panasonic BI01010001010000000000000515BI0100001399 10 Each
289 116 Supply and Installation of 2MP IR Bullet Camera (2.8mm Lens), 1/2.8” SONY - CMOS \n2MP, 0Lux with IR LED ON, Horizontal Field of View: 113 degrees, IR Range of up to 30 meters Video Analytics: Trip Wire, Intrusion Detection and Motion Detection\nH.265/H.264/MJPEG Video Compression, PoE Support, NAS Storage, SD Card(512GB), Quad Stream Support, True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB, IP66, BIS, CE, FCC and RoHS Make- Matrix / Samsung / Panasonic BI01010001010000000000000515BI0100001400 12 Each
290 117 Supply and Installation of 32 Channel NVR with 4K Support and 2HDD Slot, 32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O, 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 & CIF Recording Resolution, 5x 4K, 16x 3MP, 24x 1080p, 54x 720p, 64x D1 Local Decoding, 2 SATA HDD Support (10TB Capacity per Slot, Hard Disk Not Included), Save Storage Space with Adaptive Recording & Camera-wise Recording Retention, SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application 512Mbps Throughput - 256 Uplink, 256 Downlink, ONVIF Make- Matrix / Samsung / Panasonic BI01010001010000000000000515BI0100001401 1 Each
291 118 Supply and Installation of 6 TB Hard Drive for NVR as required.Make: WD / Seagate / Hitachi BI01010001010000000000000515BI0100001402 1 Each
292 119 Supply and Installation of 32” HD LED display, HDMI inbuilt etc complete as required Make- LG / Samsung / Sony BI01010001010000000000000515BI0100001403 1 Each
293 120 Supply and Installation of 4/2/20 Digital EPABX System including PPM Module and Expandable upto 48 ports. Make-Matrix / NEC / Panasonic BI01010001010000000000000515BI0100001404 1 Each
294 121 Supply and Installation of Digital Handset Make-Matrix / NEC / Panasonic BI01010001010000000000000515BI0100001405 2 Each
295 122 Supply and Installation of Non-CLI Telephone Make-Beetel / BPL / Panasonic BI01010001010000000000000515BI0100001406 15 Each
296 123 Supply and Installation of 50Pair DP Box BI01010001010000000000000515BI0100001407 3 Each
297 124 Supplying and drawing of 10Pair .5mm PIJF Armored Telephone Copper Cable in the existing surface/ recessed Steel/ PVC conduit as required. Make- Finolex / Polycab / RR BI01010001010000000000000515BI0100001408 100 Mtr.
298 125 Supplying and drawing of Cat5 UTP Copper Cable in the existing surface/ recessed Steel/ PVC conduit as required. Make- D-Link / Molex / Tyco BI01010001010000000000000515BI0100001409 450 Mtr.
299 126 Air-Conditioning System BI01010001010000000000000515BI0100001410
300 127 Supply of 2.0TR Split type Air-Conditioner (3 star) complete including copper piping & inter-connection between indoor unit to outdoor unit,copper pipe with insulation, supply of sundry materials, making connection from suitable point outlet, making good the damages cause complete as required and as per direction of Engineer-in-Charge BI01010001010000000000000515BI0100001411
301 127.01 2.0TR Split A.C. (3 Star rated), equivalent to Model No. RMC324HBD of Hitachi make or equivalent. BI01010001010000000000000515BI0100001412 30 Nos
302 127.02 Installation of above Split type Air-Conditioner BI01010001010000000000000515BI0100001413 30 Nos
303 128 Supply & laying of refrigerant copper piping including cutting of wall / floors with cement plastering of the same with insulation for split type A.C. BI01010001010000000000000515BI0100001414 160 Mtr
304 129 Supply & laying of flexible drainage pipe of 20mm with clamping for split type A.C. BI01010001010000000000000515BI0100001415 150 Mtr
305 130 Supply & laying of PVC drainage pipe of 25mm size with clamping for split type A.C. BI01010001010000000000000515BI0100001416 200 Mtr
306 131 Wall hanging type voltage stabilizer 5 KVA ( 130V-280V) BI01010001010000000000000515BI0100001417 30 Nos
307 132 Supply and installation of Outdoor factory fabricated stand for AC outdoor unit. BI01010001010000000000000515BI0100001418 30 Nos
308 133 PH PORTION BI01010001010000000000000515BI0100001419
309 134 Internal PH work BI01010001010000000000000515BI0100001420
310 135 Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes SDR-11 as per IS-15778/2007 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation scaffolding etc. excluding GST as per specification and direction of Engineer-in-charge. Make:ASTRAL / ASHRIVAD / AJAY / SUPREME BI01010001010000000000000515BI0100001421
311 135.01 20mm dia BI01010001010000000000000515BI0100001422 75 Mtr.
312 135.02 25mm dia BI01010001010000000000000515BI0100001423 75 Mtr.
313 135.03 32mm dia BI01010001010000000000000515BI0100001424 60 Mtr.
314 135.04 40mm dia BI01010001010000000000000515BI0100001425 40 Mtr.
315 135.05 50mm dia BI01010001010000000000000515BI0100001426 40 Mtr.
316 136 Providing all materials, labour, T&P for laying/ fixing of following dia CPVC pipes Sch-80 as per ASTM-F-441 including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation, scaffolding etc. as per specification excluding GST and direction of Engineer-in-charge. Make:ASTRAL / ASHRIVAD / AJAYA / SUPREME. BI01010001010000000000000515BI0100001427
317 136.01 75mm dia BI01010001010000000000000515BI0100001428 200 Mtr.
318 137 Providing all materials, labour, T&P for laying/ fixing of following dia uPVC solvent welded pipes Sch-80 as per ASTM-D-1785 including fixing of required size uPVC Schedule-80 fittings as per ASTM D-2467 like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation, scaffolding etc. as per specification excluding GST and direction of Engineer-in-charge. Make:ASTRAL / ASHRIVAD / AJAYA / SUPREME. BI01010001010000000000000515BI0100001429
319 137.01 40mm dia BI01010001010000000000000515BI0100001430 24 Mtr.
320 137.02 50mm dia BI01010001010000000000000515BI0100001431 47 Mtr.
321 137.03 80mm dia BI01010001010000000000000515BI0100001432 152 Mtr.
322 138 Providing all materials, labour, T&P for laying/fixing of following dia uPVC pipes as per IS-4985 with ISI mark of 6 kgf/Sq cm (Class-IV) including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation, scaffolding etc. as per specification excluding GST and direction of Engineer-in-charge. (Make: Astral / Hari Plast / Hari Udyog (P Ltd.) / Oriplast Ltd / Duro Pipes Pvt Ltd / Neel Plast) BI01010001010000000000000515BI0100001433
323 138.01 50mm dia BI01010001010000000000000515BI0100001434 86 Mtr.
324 139 Providing all materials, labour, T&P for fitting & fixing of following CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI mark as per ASTM D-2846 in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of transportation scaffolding etc. all complete as per specification excluding GST and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAY / SUPREME BI01010001010000000000000515BI0100001435
325 139.01 25mm dia CPVC ball valve BI01010001010000000000000515BI0100001436 15 Nos
326 139.02 32mm dia CPVC ball valve BI01010001010000000000000515BI0100001437 20 Nos
327 139.03 50mm dia CPVC ball valve BI01010001010000000000000515BI0100001438 10 Nos
328 139.04 80 mm dia CPVC ball valve BI01010001010000000000000515BI0100001439 10 Nos
329 140 Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of all materials, curing, conveyance of all materials etc. all complete excluding GST as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001440 1109 Mtr.
330 141 Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, duties etc. all complete as per specification excluding GST & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001441
331 141.01 For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall BI01010001010000000000000515BI0100001442 360 Nos.
332 141.02 For 75mm to 150mm dia pipe to pass in 250mm thick wall BI01010001010000000000000515BI0100001443 336 Nos.
333 142 Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete excluding GST as per the direction of the Engineer-in-charge. BI01010001010000000000000515BI0100001444 118 Nos.
334 143 Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china water closet (European pattern) 'P' or 'S' type of approved make as per IS-2556 with ISI mark in all floor including supply of sutaible PVC wall plug and Brass screws etc. all complete including cost of PVC seat cover (solid) with hinges & rubber buffers including testing etc. all complete with all cost, and conveyance as per specification all complete excluding GST as per direction of Engineer-in-charge. Make :( Hindware 20011 ) BI01010001010000000000000515BI0100001445
335 143.01 European Water closet With Cistern . BI01010001010000000000000515BI0100001446 14 Nos.
336 144 Supply all materials and labour for fitting and fixing of following size white glazed vitreous china wash hand basin with half pedestal of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete etc. including transportation etc. all complete excluding GST as per direction of EIC. Make: Hindware (10100) BI01010001010000000000000515BI0100001447
337 144.01 Wash Hand Basin with Standard Pedestal of size (550x400 mm) . BI01010001010000000000000515BI0100001448 14 Set
338 145 Supply all materials and labour for fitting and fixing of following size stainless steel kitchen sink of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete etc. including transportation etc. all complete excluding GST as per direction of EIC. Make: parryware C855371 BI01010001010000000000000515BI0100001449
339 145.01 KITCHEN SINK ( 450x400x225)mm. BI01010001010000000000000515BI0100001450 6 Set
340 146 Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china flat back, lipped front urinal basin confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from water supply pipe with transportation etc. all complete as per specification excluding GST & direction of the Engineer-in-charge. Make: Hindware (60002) BI01010001010000000000000515BI0100001451
341 146.01 610 x 410 x 380 mm size flat back large standing urinal. BI01010001010000000000000515BI0100001452 5 Set
342 147 Providing all materials, labour, T&P for fixing of following sizes of bevelled edge mirror of 5mm thick mounted on 6mm thick AC back sheet & CP cup screw with PVC wall plugs in all floor including cost, conveyance, all materials complete as per specification excluding GST and direction of E.I.C. Make-(Parryware C862899) BI01010001010000000000000515BI0100001453
343 147.01 600mm x 450mm size. BI01010001010000000000000515BI0100001454 5 Nos.
344 148 Providing all materials, labour,T&P ,fittings and fixing of different water supply (CP on Brass) fitting (Quarter Turn or as specified) as per IS specification & approved make in all floor of following sizes and specification with leak proof threaded joints with thread seal tape or any other method as required and directed including transportation etc., testing and rectification of defects after testing complete excluding GST as per direction of Engineer-in-charge. Make:JAQUAR / PARRYWARE / HINDWARE. \n BI01010001010000000000000515BI0100001455
345 148.01 15mm dia Two-Way Bibcock with wall flange. BI01010001010000000000000515BI0100001456 14 Nos.
346 148.02 15mm dia Angle Stop cock with wall flange . BI01010001010000000000000515BI0100001457 14 Nos.
347 148.03 C.P. Soap Dish Holder. BI01010001010000000000000515BI0100001458 28 Nos.
348 148.04 Health Faucet ABS SS braided hose 1.00m with CP hook. BI01010001010000000000000515BI0100001459 14 Nos.
349 148.05 32mm dia C.P.waste (Half Threaded) BI01010001010000000000000515BI0100001460 14 Nos.
350 148.06 32mm dia C.P. Dome Waste (Full Threaded) BI01010001010000000000000515BI0100001461 14 Nos.
351 148.07 15mmx50mm C.P. Extension piece BI01010001010000000000000515BI0100001462 18 Nos.
352 148.08 15mm CP Spreader BI01010001010000000000000515BI0100001463 5 Nos.
353 148.09 CP Grating. BI01010001010000000000000515BI0100001464 25 Nos.
354 148.1 CP Toilet Paper Holder. BI01010001010000000000000515BI0100001465 14 Nos.
355 148.11 Towel Ring. BI01010001010000000000000515BI0100001466 28 Nos.
356 148.12 Double Coat Hook. BI01010001010000000000000515BI0100001467 14 Nos.
357 148.13 600 mm long Gass shelf with Glass. BI01010001010000000000000515BI0100001468 14 Nos.
358 148.14 600 mm long Towel Rail. BI01010001010000000000000515BI0100001469 14 Nos.
359 148.15 sink cock BI01010001010000000000000515BI0100001470 6 Nos.
360 148.16 Long Body Bib-Cock. BI01010001010000000000000515BI0100001471 14 Nos.
361 148.17 Urinal Auto flush cock BI01010001010000000000000515BI0100001472 5 Nos.
362 149 Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification excluding GST & direction of the Engineer-in-charge. \nMake: ASTRAL/ASHIRVAD/AJAY/ SUPREME. BI01010001010000000000000515BI0100001473
363 149.01 110mm dia pipe BI01010001010000000000000515BI0100001474 500 Mtr.
364 150 Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Co-moulded Ring type) fittings of approved make confirming to IS-14735 with ISI marked in all floor with transportation & requisite testing as per specification excluding GST & direction of EIC.\nMake: ASTRAL/ASHIRVAD/AJAY/ SUPREME. BI01010001010000000000000515BI0100001475
365 150.01 110mm x110mm P-Trap BI01010001010000000000000515BI0100001476 35 Nos.
366 150.02 110mmx87.5º Plane bend BI01010001010000000000000515BI0100001477 40 Nos.
367 150.03 110mmx87.5º door bend BI01010001010000000000000515BI0100001478 20 Nos.
368 150.04 110mmx45º Plane Bend BI01010001010000000000000515BI0100001479 85 Nos.
369 150.05 110mm dia Single Tee BI01010001010000000000000515BI0100001480 62 Nos.
370 150.06 110mm Single Tee with Door BI01010001010000000000000515BI0100001481 25 Nos.
371 150.07 110mm dia single 'Y' with door BI01010001010000000000000515BI0100001482 32 Nos.
372 150.08 110mm WC connector/Bend with lip ring BI01010001010000000000000515BI0100001483 18 Nos.
373 150.09 110mm dia Vent cowl BI01010001010000000000000515BI0100001484 11 Nos.
374 150.1 PVC Clamp Suitable for 110mm dia pipe BI01010001010000000000000515BI0100001485 110 Nos.
375 150.11 110mm Socket plug BI01010001010000000000000515BI0100001486 42 Nos.
376 150.12 110mm single Y without door BI01010001010000000000000515BI0100001487 54 Nos.
377 150.13 110mm Double Y with door BI01010001010000000000000515BI0100001488 60 Nos.
378 150.14 110mm Pushfit Coupler BI01010001010000000000000515BI0100001489 35 Nos.
379 150.15 110mm Deam Seal BI01010001010000000000000515BI0100001490 150 Nos.
380 151 Providing all materials, labour, T&P for fitting and fixing of following size of 12mm thick toughened glass for urinal partition of approved make in all floor with edge moulding & polishing with chromium plated brass screws, G/W brackets 90° (Double Sided Back Plate) of DORMA make including cost of transportation etc. all complete excluding GST as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001491
381 151.01 Toughened glass partition of Size-1200mm ht. x 600mm width for Urinal Partition . (Make:DORMA/EQUIVALENT) BI01010001010000000000000515BI0100001492 5 Nos.
382 152 Providing, Fitting,fixing including ,testing & Commissioning of following capacity polyethylene moulded water storage cylindrical tank including cutting holes of required size & shape & Providing, fitting and fixing of CPVC Water tank connector/Adaptor with jam nut etc. for filling, delivery, overflow & wash out arrangements,including hoisting upto required height above the ground level & placing the tank of required position including construction of RCC pedestal upto 600mm ht. from the terrace with RCC (M-25) base slab,beam of approved design & 125mm thick brick masonary wall upto 2/3 ht. of tank (all round) in CM 1:4,12mm CP 1:4 over Brick work etc all complete as per Specification excluding GST & direction of EIC. (Make:Sintex) BI01010001010000000000000515BI0100001493
383 152.01 2000 Litres Capacity for drinking Polyethylene moulded water storage tank with lid & locking arrangement as per IS-12701/1996 with ISI mark. BI01010001010000000000000515BI0100001494 4 Nos.
384 152.02 5000 Litres Capacity for Fire Fighting Polyethylene moulded water storage tank with lid & locking arrangement as per IS-12701/1996 with ISI mark. BI01010001010000000000000515BI0100001495 2 Nos.
385 153 Supply, installation,testing & commisioning of water cooler with built in RO water purifier with chiller in all floor of following capacity including fixing the same on the floor with necessary water connection & waste arrengments with all labour, T&P etc.all complete as per the specification excluding GST & direction of EIC. (AG Green Pure chill 80ss) BI01010001010000000000000515BI0100001496
386 153.01 Chilling Capacity upto 25 ltr/hr & Purification capacity 20 ltr. BI01010001010000000000000515BI0100001497 2 Set
387 154 Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size flyash Brick having crushing strength not less than 75kg/sqcm in CM 1:6 over a bed of 100mm thick C.C. (1:1.5:3) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:6 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of 110mm square PVC Gully Trap with grating and pre-cast factory made (SFRC) cover with frame of opening size 260mmx260mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size,earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50mt lead as per specification, design & drawing including cost of curing and royality, cost, conveyance etc. all complete as per specification excluding GST& direction of EIC. BI01010001010000000000000515BI0100001498
388 154.01 300mm x 300mm x upto 450mm deep gully trap. BI01010001010000000000000515BI0100001499 6 Nos.
389 155 Providing all materials, labour T&P for construction of inspection chamber with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:4:8 with 40mm size hard granite crusher broken metal of 150mm thick, 12mm thick cement plaster 1:6 both in outer & inner surface of the wall & bottom, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed. RCC M-20 with 20mm & down size H.G crusher broken chips having minimum cube strength 200Kg/Sqcm at 28 days confirming to IS-453/76 & IS-3370 for roof slab of 125mm average thick with form work as per the requied size including cost for MS reinforcement as per approved design & drawing & fixing of Pre-cast factory made manhole cover with frame (SFRC medium duty) for opening of 500mm including cost of all materials, labour, T&P etc. complete as per specification excluding GST & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001500
390 155.01 Inner size 750mm x 750mm x 750mm depth BI01010001010000000000000515BI0100001501 10 Nos.
391 156 Providing all labour, T&P and machinaries for drilling hole by Core Cutting up to 200 mm thick RCC Wall by horizontal/vertical drilling method through mechanical means for taking PVC pipes up to 160mm dia in all floors and making good the damages with cement concrete 1:1/2:3 with required water proofing & finished smooth to original shape.The cost inclusive of hire & running charges of machinaries, to & fro charges with all consumables, scaffolding etc. required for the work etc. all complete excluding GST as per specification & direction of EIC. BI01010001010000000000000515BI0100001502 264 Each
392 157 External Water Supply & SI work BI01010001010000000000000515BI0100001503
393 158 External Laying of Sewerage Gravity System BI01010001010000000000000515BI0100001504
394 159 Supply all materials,labour & T& P for construction of swerage kitchen waste pipe line trench including collection of waste water by laying of PCC (1:3:6) . all complete as per technical specification excluding GST & direction of EIC. BI01010001010000000000000515BI0100001505 60 Mtr.
395 160 Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification excluding GST & direction of the Engineer-in-charge. \nMake: ASTRAL/ASHIRVAD/AJAY/ SUPREME. BI01010001010000000000000515BI0100001506
396 160.01 110mm dia pipe BI01010001010000000000000515BI0100001507 250 Mtr.
397 161 Providing all material,labour,T2p required for construction of RCC M25 MH Chamber of following sizes having cube strength 250 kg/cm2 at 28 days conforming of IS code-456/2 or 2163370 at all location using H.G stone aggregate C.B of 20 mm down size including machine mixing,lifting,hosting,conveying placing in position ,mechanical consideration using dewatering (if required) .The MH thickness of RCC slab,all side wall,roof slab not less than 150 mm ,150 mm to 125 mm average .The cost shall be including of rigid ,leveling,plumbed centering shutering to required slope aligment size for all kinds of RCC work with steel /ply centering material all complete as per technical specification excluding GST & direction of EIC. BI01010001010000000000000515BI0100001508
398 161.01 Manhole chamber of Inner size 800mmx900mmx 900mm depth. BI01010001010000000000000515BI0100001509 14 Nos.
399 161.02 Extra for every additional depth of 0.10mtr. or part there of manhole size 800mmx900mm from 900mm depth upto 1500mm depth. BI01010001010000000000000515BI0100001510 1.5 Mtr.
400 162 Supplying all material, labour, T&P and construction following size septic tank with 2 years cleaning interval as per the approved drawing & specification with 500mm, 375mm & 250mm thick 1st class F.B. brick in C.M.(1:6), over a bed of 100mm thick P.C.C.(1:4:8) , 150mm thick PCC (1:2:4) & 40mm thick (Avg.) A.S flooring inside wall plastering with 12mm thick C.P. in C.M. (1:4) including neat cement punning, outside wall plastering with 16mm thick CP in C.M.(1:4), RCC slab of 125 mm thick (Avg.) with M-20 concrete using 20mm down graded chips with necessary reinforcement, centering and shuttering including two nos of SFRC manhole cover with frame of approved quality with inlet & outlet chamber of size 750x750x450mm ,one partition wall & two baffle walls, supply, fitting and fixing of necessary specials & fittings Tee, vent pipe, PVC foot rest including excavation of earth, in all kind of soil including bailing out water and shoring, shuttering etc. as necessary and back filling the sides of tank including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing, etc. required for the work complete in all respect as per specification excluding GST as directed by the Engineer- in -charge. BI01010001010000000000000515BI0100001511
401 162.01 100user Septic tank of size ( 5.7 M X 2.1 M x 1.7 M with free bord 1.30 M) BI01010001010000000000000515BI0100001512 2 Job
402 163 Supplying all materials, labour, T&P and constructing soak way pit of the following size with dry F.A brick work from buttom to invert level of inlet pipe (500 mm thick wall for 0.7 Mtr. depth & 375 mm thick wall for 0.8 Mtr. depth) and F.A brick work of 250 mm thick in CM (1:4) using F.A brick having crushing strength not less than 75 Kg/ Sqcm for the remaining height (not less than 0.5 Mtr.), 12 mm thick cement plaster (1:4) both inside & outside of top brick work, RCC 125 mm thick (avg.) cover slab in C.C. (1:1:5:3) using 12 mm size h.g. chips, fitting with factory made SFRC manhole cover ( medium duty) of size 500 mm dia, including earth work in excavation in hard soil, filling inside of the pit with 40 mm size h.g. metals upto invert level, surrounding the outside angular space with 40 mm size h.g. metal for 150 mm thick back filling the remaining portion inluding top 0.5 Mtr. with excavated selected earth, leveling the surface around the chamber with the disposal of surplus earth if any, to a distance of 50 Mtr. as per the specification, design & drawing etc. all complete as per specification excluding GST & direction of the Engineer-in-charge. BI01010001010000000000000515BI0100001513
403 163.01 1.5 Mtr. dia x 3.0 Mtr. deep soak way pit. BI01010001010000000000000515BI0100001514 2 NOS
404 164 Sinking of 200mm x 150mm Dia Production Well BI01010001010000000000000515BI0100001515
405 165 Conducting reconnaissance survey, integrated Hydrological & Geophysical (Electrical Ressistivity method) survey and selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling production wells in selected area. BI01010001010000000000000515BI0100001516 1 Job
406 166 Labour for drilling a perfectly vertical bore hole for a specified dia for a specified depth below G.L through consolidated and un-consolidated rocks with down the hole hammer drilling rig or combination drilling rig (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of EIC including use of own rigs with its accessories, T&P & consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/ PVC casing pipes, if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the Tube Well). AG Green Pure chill 80SS BI01010001010000000000000515BI0100001517
407 166.01 Labour for drilling of 200mm dia & 150mm dia bore from '0' mtr. to '100' mtr. BI01010001010000000000000515BI0100001518 100 Mtr.
408 167 Providing & lowering the following size PVC pipes (ASTM) with or without slotted pipes as per the necessity from 1.00m above ground level up to required depth and fitting and fixing up in perfectly vertical position, including cutting, threading pipe and slotted pipe and supplying and fixing all jointing materials, T&P etc. complete and keeping the top of the casing pipe threaded including plugging the tube well to prevent entry of foreign materials from above. The cost inclusive of pipes, fittings, labour, consumables, POL, consumables with hire & running charges of machinaries etc. as per specification excluding GST & direction of EIC. BI01010001010000000000000515BI0100001519
409 167.01 Lowering of 200mm (8'') dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 upto required depth. BI01010001010000000000000515BI0100001520 60 Mtr.
410 167.02 Cost of 200mm (8'') dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 BI01010001010000000000000515BI0100001521 60 Mtr.
411 168 Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment , labour, all consumables, running & hire charges of machinaries etc. all complete excluding GST & direction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001522 1 Job
412 169 Supplying all materials, labour & tools and plant and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3mtrs below ground level to plug the bore hole including cost of cement all complete as per specification excluding GST & direction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001523 10 Mtr.
413 170 Providing all materials required for construction of brick masonry chamber for encasing the production well with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 150mm thick on base & 100mm thick on top of the chamber, encasing the annular area of casing pipe with cement concrete 1:2:4 of minimum size 450mmx450mmx1200mm height including form work, filling the inside cavity with sand, C.C. 1:2:4 on top of the chamber of 50mm thick, 12mm thick cement plaster 1:4 on outer wall & top surface, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed with smooth finishing. The height of chamber should be 450mm from G.L. The cost inclusive of all materials, labour, T&P etc. complete as per specification excluding GST & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001524
414 170.01 Outer size 1400mm x 1400mm x 1200mm ht. chambers BI01010001010000000000000515BI0100001525 2 Nos.
415 171 Design, Construction,Testing and Commissioning of RCC UGR of 40 KL for drinking and 50KL for fire with provision for filling, delivery, overflow and washout piping arrangement including provision for suction chamber inside the UGR of minimum size- below the floor level of UGR etc including Construction of clear water pump house of inner size (2.25x5.00x3.00)mtr . all complete as per technical specification excluding GST & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001526 1 Job
416 172 Supply, installation, testing and commisioning of automatic star delta control panel suitable for 5 HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the sump with suitable cable etc complete excluding GST & direction of Engineer-in-charge. (Excluding power supply). BI01010001010000000000000515BI0100001527 1 SET
417 173 Supply, Installation, testing & commissioning of 3-phase, 50Hz Submersible pump set of required head & discharge including HDPE delivery pipes of 10 Kgf/cm2 of material grade P.E.-80, Suitable size of three core flat cable with Bore bunched copper conductor insulated sheathed with PVC for Submersible Motor with voltage grade up to 1100 Volt confirming to IS-694/1990 of required length, control panel & required accessories suitable for 200x150mm size Production Well etc. complete in all respect excluding GST as per direction of Engineer-in-charge. (Excluding power supply). BI01010001010000000000000515BI0100001528 1 SET
418 174 Supply, installation, testing & commissioning of Centrifugal Pump set (split casing). The capacity of each pump, Total Head-25.00m, Discharge-7.00 lps with 3-phase 50Hz, TEFC induction motor coupled with a common base with electrical control panel suitable for the pump set, including construction of concrete foundation, suction & delivery piping arrangements, fixing of required sizes & nos.of C.I. valves (pressure ratting PN-1.0) like Sluice valves (rising spindle), Butterfly valves, NR valves & flanged end foot valve with strainer etc. all complete as per the specification & direction of EIC. (2 (Two) set i.e. 1 (One) working & 1 (One) standby)etc. complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001529 1 JOB
419 174.01 Construction of Rain water harvesting System. BI01010001010000000000000515BI0100001530
420 175 Supply all materials,labour & T& P for construction of Rain Water Recharge Pits including collection of rain water by laying of SWR Type-A pipes, collection chamber from different source both from roof & inside the Premises etc. all complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001531
421 175.01 Inner size 1.2 mtr x 2.00 mtr depth of 200 mm Bore 50 mtr BI01010001010000000000000515BI0100001532 2 No.
422 176 Construction of Rain water pipe line System. BI01010001010000000000000515BI0100001533
423 176.01 Supply all materials,labour & T& P for construction rain water pipe line trench including collection of rain water from roof by laying of PCC (1:3:6) . all complete in all respect excluding GST as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001534
424 176.02 Inner size 350 mm & depth of 300 mm BI01010001010000000000000515BI0100001535 133 Mtr.