Supplying And Installation Of 200 Kva Transformer And Panel Board At Processing Plant Kanchanwadi, TOWN HALL AURANGABAD-Maharashtra

Aurangabad Municipal Corporation has published Supplying And Installation Of 200 Kva Transformer And Panel Board At Processing Plant Kanchanwadi. Submission Date for this Tender is 18-12-2020. Screws Tenders in TOWN HALL AURANGABAD Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26174905
Supplying And Installation Of 200 Kva Transformer And Panel Board At Processing Plant Kanchanwadi
Open Tender
Indian
Maharashtra
TOWN HALL AURANGABAD
18-12-2020

Tender Details

Supplying And Installation Of 200 Kva Transformer And Panel Board At Processing Plant Kanchanwadi , Supplying And Recting Aluminium Strip Of Required Sizes Used For Earthing On Wall And/Or Any Other Purpose With Necessary Aluminium Clamps Fixed On Wall With Insulating And Non-Corrosive Bond In An Approved Manner With Required Joints . As Per Specification No . Ea-Ep Dsr No . 9-2-6 , Providing Earthing With Galvanized Iron Earth Plate Size 60X60x0 . 6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C . I . Cover Complete With All Materials , Testing & Recording The Results As Per Specification No . Ea-Ep Dsr No . 9-1-3 , Supplying And Recting Armoured Cable 4 Core 185 Sq . Mm Aluminium Conductor With Continous 12 . 97 Sq . Mm ( 8 Swg ) G . I . Earth Wire Complete Erected With Glands And Lungs On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No . Cb-Lt/Al Dsr No . 7-1-37 , Supplying , Installing , Testing And Commissioning 3 Phase 11/0 . 433 Kv , 50 Hz . 200 Kva , Oil Immersed And Naturally Cooled Outdoor Type , Copper Wound Transformer , Delta / Star Connected Additional Neutral Brought Out On Load Side , Temperature Rise Should Not Exceed 40Oc By Thermo Meter Ub Iuk And 45Oc By The Resistance In Winding At Full Load Rating With Hv Tapping ( With Off Load Tap Changer ) Off Load+5 To -10 In Steps Of 2 . 5% With Standard Accessories Complete With Test Certificate With Losses Below 1860 Watts At 50 % Load 5300 Watts At 100 % Loads As Per Is :1180 - 2014 Energy Efficiency Level Inspector As Per Specification No . Ss-Tr Dsr No . 10-1-5 , Supply And Erecting Gi Earth Wire Of High Purity Of Different Sizes Used For Earthing Or Any Other Purpose On Wall With Necessary Gi Clamps Fixed On Wall / Cable / Conduit With Screws In An Approved Manner . Dsr No . 9-2-5 , Making M-20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq . M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template Duly Plastered As Per Design Complete ( For 20 M Raising Lowering High Mast ) Dsr No . 16-3-14 , Providing Earthing With Copper Earth Size 60X60x0 . 315 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C . I . Cover With Minimum 25 Kg Carbon Based Environment Freindly Back Fill Ground Enhancing Compound Complete With All Materials , Testing And Recording The Results As Per Specification No . Ese-La Dsr No . 9-1-6 , Making Cement Concrete Foundation ( A ) Excavation =1 . 07X1 . 52X1 . 52=2 . 472 M3 X 247 . 45 = 611 . 69 /- Ssr 21 . 12/2019-20 ( B ) Concreting = 1 . 07X1 . 52X1 . 52 = 2 . 47 M3 X 6493 . 22 = 16038/- Ssr 25 . 13/2019-20 ( C ) Rcc Colum = 1 . 52 X 1 . 52 X 1 . 52 = 3 . 51 M3 X 12310 . 30 = 43209/- Ssr 25 . 33/2019-20 , Supplying And Erecting Led Flood Light Fitting Of 200W , Including Lamp With Pf > 0 . 95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification No . Fg-Odf/Fls-2 Dsr No . 2-5-18 , Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Dsr No . 5-2-15 , Making Trench Of Suitable Width And Depth In Hard Murum / Tar Road For Laying Provided Lt Cable Of 16 Sq . Mm And Above And Covered With Half Round Hume Pipe Complete As Per Specification No . Cw-Exn-Ctr Dsr No . 16-1-3 , Supplying , Erecting & Terminating Xlpe Armoured Cable 3 1/2 Core 10 Sq . Mm Aluminium Conductor With Continous 12 . 97 Sq . Mm ( 8 Swg ) Gi Earth Wire Complete Erected With Glands & Lugs On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No . Cb-Lt/Al Dsr No . 7-1-28 , Supplying And Erecting 16M ( Clear Height ) High Mast ( Top-150 Mm , Bottom - 410 Mm ) With Lowering And Raising Motorized Un Lantern Carriage Assembly Suitable For Max 12 Nos . Luminaries And Its Contol Gear Box , Lightning Final Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification No . Oh-Pl/Hm ( Excluding Luminaries Dsr No . 8-3-3 , Supplying & Erecting Street Light Control Panel In Powder Coated Dsr No . 5-2-17 , Supplying And Erecting D . P Structure For 11/0 . 415 Kv , Transformer With R . S . J . Poler 2 Nos Of Size 100 Mm X 116 Mm X 11M Long With Suitable Distribution Box Of C . R . C . A . Sheet 16 Swg With 4 Pole Mccb 300 Amps As Incomer & 6 Nos . 100 Amps Kitkat / Mccb For Outgoing Circuits . Transformer Dp Structure Includes Th A . B . Switch 200 Amps . D . O . Fuse Set And La Set 2 Nos Top Channel Of Size 100Mm X 50Mm For Erection Of A . B . Switch & 2 Nos Base Channerl Of Size 100Mm X 50 Mm For Erecting Transformer . Channel Of Size 75X40 Mm For Erecting D . O . Fuse Set La Ab Switch Handle Etc . Angles Of Size 50X50x6mm For Erecting Distribution Box , Transformer Belt Etc . As Per Drawing ( Min 124 Kg . Iron Work ) With Necessary Clamps , Nut Bolts , Vee Cross Arm , Top Clip , Insulator Etc . Complete With Caution Borad & Barbed Wire . Dp Structure Shall Be Erected In Cc Foudnation Complete . Dsr No . 8-4-26 , 12% Gst

Key Value

Document Fees
INR 600 /-
EMD
INR 18000.0 /-
Tender Value
INR 18.08 Lakhs /-

BOQ Items

Name of Work : Supplying and Installation of 200 KVA transformer and panel board at processing plant Kanchanwadi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supplying and recting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond in an approved manner with required joints. As per specification No.EA-EP DSR No.9-2-6 1 1 Kg
2 2 Providing earthing with galvanized iron earth plate size 60x60x0.6 cm with funnel with a wire mesh for watering and brick masonry block C.I. Cover complete with all materials, testing & recording the results as per specification No.EA-EP DSR No.9-1-3 2 10 Each
3 3 Supplying and recting armoured cable 4 core 185 sq.mm aluminium conductor with continous 12.97 sq.mm (8 SWG) G.I. Earth wire complete erected with glands and lungs on wall / trusses / pole or laid in provided trench / pipe as per specification No.CB-LT/AL DSR No.7-1-37 3 250 Mtr
4 4 Supplying, installing, testing and commissioning 3 phase 11/0.433 kV,50 Hz.200 KVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta / star connected additional neutral brought out on load side, temperature rise should not exceed 40oC by thermo meter ub iuk and 45oC by the resistance in winding at full load rating with HV tapping (with off load tap changer) off load+5 to -10 in steps of 2.5% with standard accessories complete with test certificate with losses below 1860 watts at 50 % load 5300 watts at 100 % loads as per IS :1180 - 2014 energy efficiency level inspector as per specification No.SS-TR DSR No.10-1-5 4 1 Each
5 5 Supply and erecting GI earth wire of high purity of different sizes used for earthing or any other purpose on wall with necessary GI clamps fixed on wall / cable / conduit with screws in an approved manner. DSR No.9-2-5 5 25 Kg
6 6 Making M-20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 20 m raising lowering high mast) DSR No.16-3-14 6 1 Each
7 7 Providing earthing with copper earth size 60x60x0.315 cm with funnel with a wire mesh for watering and brick masonry block C.I. Cover with minimum 25 kg carbon based environment freindly back fill ground enhancing compound complete with all materials, testing and recording the results as per specification No.ESE-LA DSR No.9-1-6 7 1 Each
8 8 Making cement concrete foundation (a) excavation =1.07x1.52x1.52=2.472 M3 x 247.45 = 611.69 /- SSR 21.12/2019-20 (b) Concreting = 1.07x1.52x1.52 = 2.47 M3 x 6493.22 = 16038/- SSR 25.13/2019-20 (c) RCC colum = 1.52 x 1.52 x 1.52 = 3.51 M3 x 12310.30 = 43209/- SSR 25.33/2019-20 8 1 Job
9 9 Supplying and erecting LED flood light fitting of 200W, including lamp with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No.FG-ODF/FLS-2 DSR No.2-5-18 9 6 Each
10 10 Supplying and erecting mini feeder pillar triple pole with 300A DSR No.5-2-15 10 2 Each
11 11 Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq.mm and above and covered with half round hume pipe complete as per specification No.CW-EXN-CTR DSR No.16-1-3 11 225 Mtr
12 12 Supplying, erecting & terminating XLPE armoured cable 3 1/2 core 10 sq.mm aluminium conductor with continous 12.97 sq.mm (8 SWG) GI earth wire complete erected with glands & lugs on wall / trusses / pole or laid in provided trench / pipe as per specification No.CB-LT/AL DSR No.7-1-28 12 112 Mtr
13 13 Supplying and erecting 16m (clear height) high mast (Top-150 mm, bottom - 410 mm) with lowering and raising motorized un lantern carriage assembly suitable for max 12 nos. Luminaries and its contol gear box, lightning final arrangement for fixing aviation light and foundation bolts on provided foundation as per specification No.OH-PL/HM (excluding luminaries DSR No.8-3-3 13 1 Each
14 14 Supplying & erecting street light control panel in powder coated DSR No.5-2-17 14 1 Each
15 15 Supplying and erecting D.P structure for 11/0.415 kV, transformer with R.S.J. Poler 2 nos of size 100 mm x 116 mm x 11m long with suitable distribution box of C.R.C.A. Sheet 16 SWG with 4 pole MCCB 300 amps as incomer & 6 nos. 100 amps kitkat / MCCB for outgoing circuits. Transformer DP structure includes th A.B. switch 200 Amps. D.o. fuse set and LA set 2 nos top channel of size 100mm x 50mm for erection of A.B. switch & 2 nos base channerl of size 100mm x 50 mm for erecting transformer. channel of size 75x40 mm for erecting D.O. fuse set LA AB switch handle etc. Angles of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min 124 Kg. iron work) with necessary clamps, nut bolts, vee cross arm, top clip, insulator etc. complete with caution borad & barbed wire. DP structure shall be erected in CC foudnation complete. DSR NO.8-4-26 15 1 Each
16 16 12% GST 16 1.61461e+06 Each