Assam State Housing Board has published Establishment Of Cultural Research Centre-Construction Of Guest House And Establishment Of Cultural Research Centre-Construction Of Guest House AndBoundary Wall Of Mayamara Ajoli Aai ( Ba-Bhaga Than ) Sanskritik Kendra AtMajuli . . Submission Date for this Tender is 15-12-2020. Building Work Tenders in Majuli Assam. Bidders can get complete Tender details and download the document.
Name of Work: Establishment of Cultural Research Centre-Construction of Guest House and Boundary Wall of Mayamara Ajoli Aai (Ba-Bhaga Than) Sanskritik Kendra at Majuli. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | GROUND FLOOR AREA = 518.69 SQ.MT. | Item 1 | ||
2 | 2 | Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. | Item 2 | ||
3 | 3 | I) Upto a depth of 2m below the existing ground level . | Item 3 | ||
4 | 4 | a) In ordinary soil | Item 4 | 158.4 | CU.M. |
5 | 5 | Earth/Sand filling in plinth in layers not more than 150 mm thk. including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensati -on, Forest Roalty, Sales Tax and other duties and taxes as may be necessary | Item 5 | ||
6 | 6 | I) With silt (Predominantly non plastic ) by truck carriage including loading and unloading . | Item 6 | 427.92 | CU.M. |
7 | 7 | Plain Cement Concrete works. | Item 7 | ||
8 | 8 | Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, steps, walls, brick work etc. as directed and specifoed including dewatering if necessary and curing complete (shuttering where necessary shall be be measured and paid separately) | Item 8 | ||
9 | 9 | a) In Prop. 1 cement : 3 Sand : 6 Coarse agg. by volume | Item 9 | 5.9 | CU.M. |
10 | 10 | Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) | Item 10 | ||
11 | 11 | (I) Using mixture machine | Item 11 | ||
12 | 12 | (A ) In sub-structure upto plinth level. | Item 12 | ||
13 | 13 | I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level. | Item 13 | ||
14 | 14 | N) Without using admixture, plasticiser | Item 14 | ||
15 | 15 | b) M 20 grade concrete or Prop 1:1.5:3 | Item 15 | 66.82 | CU.M. |
16 | 16 | B ) In super structure from plinth level up to 1st floor level.. | Item 16 | ||
17 | 17 | ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing. | Item 17 | ||
18 | 18 | N) Without using admixture, plasticiser | Item 18 | ||
19 | 19 | b) M 20 grade concrete or Prop 1:1.5:3 | Item 19 | 44.37 | CU.M. |
20 | 20 | iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. | Item 20 | ||
21 | 21 | N) Without using admixture, plasticiser | Item 21 | ||
22 | 22 | b) M 15 grade concrete or Prop 1:2:4 (Qty LS) | Item 22 | 2.45 | CU.M. |
23 | 23 | Providing and laying 25 mm thick damp proof course with cement concrete in prop. 1:1.5:4 with graded stone aggregate of 10mm down nominal size including providing approved damp proff mixture in prop. as recomended by the manufacturer including curing etc. complete as directed. | Item 23 | 24 | SQ.M. |
24 | 24 | BRICK WORK | Item 24 | ||
25 | 25 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panels after preparing the surface as directed including all labour and materials and if necessary dewatering complete . | Item 25 | ||
26 | 26 | a) Brick on flat soling | Item 26 | 751.31 | SQ.M. |
27 | 27 | Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level. | Item 27 | ||
28 | 28 | (I) In Sub-structure upto plinth level including dewatering if necessary | Item 28 | ||
29 | 29 | b) In proportion 1:4 | Item 29 | 32.57 | CU.M. |
30 | 30 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Item 30 | ||
31 | 31 | (A) 112 mm thick brick wall | Item 31 | ||
32 | 32 | a) In cement morter in proportion 1:4( 1 cement :4 sand) | Item 32 | 141.57 | SQ.M. |
33 | 33 | SHUTTERING AND FORM WORK | Item 33 | ||
34 | 34 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in | Item 34 | ||
35 | 35 | Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc. | Item 35 | ||
36 | 36 | a) Using 38 mm thick plank | Item 36 | 74.48 | SQ.M. |
37 | 37 | Sides of tie beams, plinth beams, grade beams etc.at or below ground level | Item 37 | ||
38 | 38 | (a)) Using 38 mm thick plank | Item 38 | 436.8 | SQ.M. |
39 | 39 | Columns, pillars ,posts & strut | Item 39 | ||
40 | 40 | (b) Circular or curved in plan (Using 38mm thick plank) | Item 40 | ||
41 | 41 | I) Using 38 mm thick plank | Item 41 | 162.9 | SQ.M. |
42 | 42 | Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties | Item 42 | ||
43 | 43 | a) For depth not exceeding 1.0M | Item 43 | ||
44 | 44 | I) Using 38 mm thick plank | Item 44 | 219.9 | SQ.M. |
45 | 45 | iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. | Item 45 | ||
46 | 46 | a) Floors etc. upto 200 mm in thickness | Item 46 | ||
47 | 47 | I) Using 38 mm thick plank | Item 47 | 61.88 | SQ.M. |
48 | 48 | Vertical ties, fins, sun breaker, louvers, band, dropwalls etc. | Item 48 | ||
49 | 49 | I) Using 38 mm thick plank | Item 49 | 5.5 | SQ.M. |
50 | 50 | Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level. | Item 50 | ||
51 | 51 | a) Thickness not exceeding 200mm | Item 51 | 3.56 | SQ.M. |
52 | 52 | PLASETRING AND POINTING | Item 52 | ||
53 | 53 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Item 53 | ||
54 | 54 | A) On rough side | Item 54 | ||
55 | 55 | b) In cement mortar 1:4 | Item 55 | 242.88 | SQ.M. |
56 | 56 | B) On fair side | Item 56 | ||
57 | 57 | b) In cement mortar 1:4 | Item 57 | 154.53 | SQ.M. |
58 | 58 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Item 58 | ||
59 | 59 | b) In cement mortar 1:4 | Item 59 | 448.24 | SQ.M. |
60 | 60 | Extra for plastering on ceiling and soffits of stair up to 1st floor level including curing complete as directed. | Item 60 | ||
61 | 61 | I) Ground floor | Item 61 | 285.34 | SQ.M. |
62 | 62 | 15 mm thick plain cement mortar bands in cement morter 1:4 in width including curing complete as directed. | Item 62 | ||
63 | 63 | A) Up to 300 mm width | Item 63 | ||
64 | 64 | a) Flush Band | Item 64 | 6.41 | SQ.M. |
65 | 65 | b) Sunk Band | Item 65 | 6.41 | SQ.M. |
66 | 66 | FLOORING : | Item 66 | ||
67 | 67 | 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. | Item 67 | 518.69 | SQ.M. |
68 | 68 | Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. | Item 68 | ||
69 | 69 | b) 20 mm thick . | Item 69 | 88.35 | SQ.M. |
70 | 70 | Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). | Item 70 | ||
71 | 71 | Executive range\nSomany/ Orient/Nitco/Asian Make | Item 71 | ||
72 | 72 | Of size 600mmx600mm and above | Item 72 | 518.69 | SQ.M. |
73 | 73 | Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). | Item 73 | 16.2 | SQ.M. |
74 | 74 | Providing 18 mm thick Granite slab on vertical face of pedestal laid over 10 mm (1 cement :3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade. | Item 74 | 8.1 | SQ.M. |
75 | 75 | Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. | Item 75 | ||
76 | 76 | Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). | Item 76 | ||
77 | 77 | 9.5mm thick | Item 77 | 615.6 | SQ.M. |
78 | 78 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Item 78 | ||
79 | 79 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Item 79 | ||
80 | 80 | (ii)Super Ductile (SD) TMT reinforcement bars | Item 80 | 130.93 | QNTL |
81 | 81 | Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws. | Item 81 | ||
82 | 82 | a) Ornamental Grill | Item 82 | ||
83 | 83 | c) Fixed to brickwork/ P.C.C/R.C.C. | Item 83 | 2513.7 | Kg |
84 | 84 | Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. | Item 84 | ||
85 | 85 | a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997 | Item 85 | 64.41 | qntl |
86 | 86 | Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) | Item 86 | ||
87 | 87 | TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement | Item 87 | ||
88 | 88 | (iv) 0.60 mm thick | Item 88 | 846.15 | SQ.M. |
89 | 89 | Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete.\nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement | Item 89 | ||
90 | 90 | (iv) 0.60 mm thick | Item 90 | 62.4 | R.M. |
91 | 91 | Painting | Item 91 | ||
92 | 92 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. | Item 92 | ||
93 | 93 | a) With ready mixed red lead red oxide primer | Item 93 | 362.93 | SQ.M. |
94 | 94 | Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter . | Item 94 | ||
95 | 95 | (I) Surfaces over 100 mm in width or girth | Item 95 | ||
96 | 96 | b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac) | Item 96 | 362.93 | SQ.M. |
97 | 97 | Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. | Item 97 | 1461.25 | SQ.M. |
98 | 98 | c) Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. | Item 98 | 1461.25 | SQ.M. |
99 | 99 | (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | Item 99 | 1461.25 | SQ.M. |
100 | 100 | a) Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth. | Item 100 | 237.69 | SQ.M. |
101 | 101 | Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats) | Item 101 | 237.69 | SQ.M. |
102 | 102 | MISCELLANEOUS | Item 102 | ||
103 | 103 | Pre construction antitermite treatment at the bottom of foundation of foundation pits and walls on either side up to a height of 300m.m. from bottom of the excavation made for column ,plinth beam, wall trenches etc. by applying the emulsion @ 5 litres per sq.mt. Of the surface area before starting construction work( supplying of necesary tools and accessories by the contractor) as per the direction of the Department complete. | Item 103 | ||
104 | 104 | a)with aquous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water ,I,e, 1% solution. | Item 104 | 518.69 | SQ.M. |
105 | 105 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | Item 105 | 58.9 | SQ.M. |
106 | 106 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. | Item 106 | ||
107 | 107 | ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. | Item 107 | 22 | RM |
108 | 108 | HARDWARE FITTINGS | Item 108 | ||
109 | 109 | Supplying, fitting and fixing alluminum fittings of approved make reasonably smooth, free from sharp edges, flows and other defacts with counter sunk holes for screws including necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish). | Item 109 | ||
110 | 110 | a) Sliding door bolts | Item 110 | ||
111 | 111 | I) 300 X 16 mm | Item 111 | 14 | Each |
112 | 112 | b) Tower bolt | Item 112 | ||
113 | 113 | I) 300 X 12 mm | Item 113 | 7 | Each |
114 | 114 | ii) 250 X 12 mm | Item 114 | 7 | Each |
115 | 115 | c) Door handle | Item 115 | ||
116 | 116 | I) 150 mm | Item 116 | 7 | Each |
117 | 117 | I) 100 mm | Item 117 | 7 | Each |
118 | 118 | e) Butt hinge v ) 100 mm x75mmx 4mm | Item 118 | 21 | Pair |
119 | 119 | INTERNAL ELECTRIFICATION WORKS | Item 119 | ||
120 | 120 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete | Item 120 | ||
121 | 121 | b)Medium point upto 6.00mtr length | Item 121 | 20 | Per point |
122 | 122 | c)Long point upto 10.00mtr length | Item 122 | 25 | Per point |
123 | 123 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. | Item 123 | ||
124 | 124 | b)Medium point upto 6.00mtr length | Item 124 | 6 | Per point |
125 | 125 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\n | Item 125 | ||
126 | 126 | Extra long point up to 25.00 metre. Length. | Item 126 | 6 | per point |
127 | 127 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. | Item 127 | ||
128 | 128 | With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 128 | 95 | per mtr |
129 | 129 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 129 | 85 | per mtr |
130 | 130 | With 2 x 16 sq. mm. + earth continuity with 1x10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 130 | 35.9 | per mtr |
131 | 131 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. | Item 131 | ||
132 | 132 | 12 way SPN double door | Item 132 | 2 | EACH |
133 | 133 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. | Item 133 | ||
134 | 134 | 6 way TPN (4+18) double door | Item 134 | 2 | EACH |
135 | 135 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | Item 135 | ||
136 | 136 | B Series\n(Schneider MG, legrand, Hager make) | Item 136 | ||
137 | 137 | 6 to 32A | Item 137 | 25 | EACH |
138 | 138 | Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | Item 138 | ||
139 | 139 | B Series\n(Schneider MG, legrand, Hager make) | Item 139 | ||
140 | 140 | 63A | Item 140 | 4 | EACH |
141 | 141 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | Item 141 | ||
142 | 142 | C Series (ABB, Schneider MG, legrand, Hager make) | Item 142 | ||
143 | 143 | 100A | Item 143 | 1 | EACH |
144 | 144 | MCCB with Thermal & Magnetic Release | Item 144 | ||
145 | 145 | Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. | Item 145 | ||
146 | 146 | 25 KA 415V 50 Hz 3P MCCB \n(Schneider, legrand, Siemens make) | Item 146 | ||
147 | 147 | 16A | Item 147 | 1 | EACH |
148 | 148 | 63A | Item 148 | 1 | EACH |
149 | 149 | Supplying including fitting and fixing of high speed AC Ceiling fan complete with all accessories like , down rod, canopy etc.of following sweeps with making necessary connection etc.as reqd complete and directed by the deptt.(Without regulator) | Item 149 | ||
150 | 150 | a) 1400mm sweep | Item 150 | 40 | each |
151 | 151 | Installation ,testing and commissioning of ceiling fan including the regulator, down rod of standard size(up to 300mm length) and connection etc complete as specified and directed by the department. | Item 151 | 40 | each |
152 | 152 | Supplying fitting and fixing of single wall brackets model 37712 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. Without lamp. | Item 152 | 5 | each |
153 | 153 | Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. | Item 153 | ||
154 | 154 | Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. | Item 154 | 40 | each |
155 | 155 | WVF 53414 SGW 4 x 14 W FTL T5) Recess mounted indirect- direct luminaries with High Efficiency Translucence (HET) Technology suitable for FTL T5) Lamps. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ JAQUAR make). | Item 155 | 3 | each |
156 | 156 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . | Item 156 | ||
157 | 157 | 185.00 Sq.mm 4 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) | Item 157 | 6 | mtr |
158 | 158 | Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | Item 158 | 1 | each |
159 | 159 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | Item 159 | 1 | each |
160 | 160 | Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | Item 160 | 6 | mtr |
161 | 161 | Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | Item 161 | 18 | mtr |
162 | 162 | Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. | Item 162 | 26 | per mtr |
163 | 163 | Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. | Item 163 | 2 | Each |
164 | 164 | Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt. | Item 164 | 20 | Each |
165 | 165 | Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. | Item 165 | ||
166 | 166 | 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no | Item 166 | ||
167 | 167 | 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. | Item 167 | ||
168 | 168 | 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set | Item 168 | ||
169 | 169 | 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. | Item 169 | ||
170 | 170 | 5. Surface mounting timer switch - 1 No. | Item 170 | ||
171 | 171 | 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos | Item 171 | ||
172 | 172 | 7. 0-40 Amp electro-mechanical counter display 3 Phase 4 wire electronic hybrid energy meter | Item 172 | 1 | Each |
173 | 173 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. | Item 173 | ||
174 | 174 | 1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) . | Item 174 | 1 | Each |
175 | 175 | SANITARY WORKS | Item 175 | ||
176 | 176 | Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately | Item 176 | ||
177 | 177 | (vi) Single Bowl (160 x 180) Flat Edge - Glossy (Cat.No.C8538) | Item 177 | 2 | Each |
178 | 178 | Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. | Item 178 | ||
179 | 179 | (A) Parryware Make | Item 179 | ||
180 | 180 | (ii) Wall Soap tray (Cat. No.C9951) | Item 180 | 2 | Each |
181 | 181 | Providing, fitting and fixing CP towel ring complete as directed and specified. | Item 181 | ||
182 | 182 | (a) Sona make | Item 182 | ||
183 | 183 | (i) Towel ring round( Cat No. TR 06051) | Item 183 | 2 | Each |
184 | 184 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. | Item 184 | ||
185 | 185 | a) In exposed surfaces or in trenches. | Item 185 | ||
186 | 186 | (ii) 110mm dia | Item 186 | 22 | R.M. |
187 | 187 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. | Item 187 | ||
188 | 188 | a) In exposed surfaces or in trenches | Item 188 | ||
189 | 189 | ii) 110 mm dia. | Item 189 | 4 | Each |
190 | 190 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. | Item 190 | ||
191 | 191 | a) In exposed surfaces or in trenches | Item 191 | ||
192 | 192 | ii) 110 mm dia. | Item 192 | 2 | Each |
193 | 193 | Providing fitting and fixing 100 mm dia PVC Cowel with ISI make complete as directed and specified. | Item 193 | 4 | Each |
194 | 194 | Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. | Item 194 | ||
195 | 195 | b) 110 mm dia | Item 195 | 2 | Each |
196 | 196 | WATER SUPPLY WORKS | Item 196 | ||
197 | 197 | Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. | Item 197 | ||
198 | 198 | (A) Exposed or in trenches | Item 198 | ||
199 | 199 | SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) | Item 199 | ||
200 | 200 | Exposed or in trenches | Item 200 | ||
201 | 201 | b) 40 mm dia | Item 201 | 15 | RM |
202 | 202 | (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. | Item 202 | ||
203 | 203 | SUPREME/ PRINCE / SFMC / FUSION BAND or other equvalent approved brand (High presure pipe Sch-40) | Item 203 | ||
204 | 204 | d) 25 mm dia | Item 204 | 6 | RM |
205 | 205 | f)15 mm dia | Item 205 | 17 | RM |
206 | 206 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) | Item 206 | ||
207 | 207 | II) Jaquar make | Item 207 | ||
208 | 208 | a) Continental/ Clarion | Item 208 | ||
209 | 209 | I) Standard | Item 209 | 4 | Each |
210 | 210 | Supplying fitting and fixing Chrome plated (C.P.) stop -cock of approved brand and size as mentioned below as directed and specified ( G.I. & C.P. pipes will be measured and paid separately) | Item 210 | ||
211 | 211 | I) Jaquar | Item 211 | ||
212 | 212 | (a) Continental /Clarion | Item 212 | ||
213 | 213 | (ii) 15 mm dia Male /Female ( Long thred) | Item 213 | 2 | Each |
214 | 214 | Supplying and fitting fixing C.P. pillar cock of 15 mm dia of approved brand as specified and directed. | Item 214 | ||
215 | 215 | ii) Jaquar make | Item 215 | ||
216 | 216 | (b)Long neck with areator | Item 216 | 2 | Each |
217 | 217 | Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed | Item 217 | ||
218 | 218 | b) 40 mm dia | Item 218 | 1 | Each |
219 | 219 | Labour for sinking tube well with 40 mm ( internal) dia G.I. Pipes up to strata, having potable water including fitting and fixing strainer , hand pump and other accessories as directed complete as in any soil | Item 219 | 21 | R.M |
220 | 220 | Supplying, fitting and fixing suction pipes ( plain/ bevel ended) , conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casting pipes complete as directed | Item 220 | ||
221 | 221 | ( I) G.I. Pipe | Item 221 | ||
222 | 222 | (a) TATA/SAIL (medium)( sockets should be welded to the pipes) | Item 222 | ||
223 | 223 | iii) 40 mm diameter | Item 223 | 21 | R.M |
224 | 224 | Supplying fitting and fixing brass Tez filter 2.00 meter long. | Item 224 | 2 | Each |
225 | 225 | Supplying fitting and fixing check valve ( non return valve ) including threads to pipes | Item 225 | ||
226 | 226 | c) 40 mm dia | Item 226 | 1 | Each |
227 | 227 | Supplying, fitting and fixing Maya Hand pump No 6 for 40 mm dia tube well with all accessories complete as directed | Item 227 | 1 | Each |
228 | 228 | Flushing , clearing, washing and watering of the tube well | Item 228 | 1 | Job |
229 | 229 | Supplying fitting and placing plastic cylindrical vertical closed top ( PCVC) tank of Sintex/ Polycon/ Patton make over the stagging with manhole cover with locking arrangement and cleaning arrangement including providing pads of sizes as required for inlet and outlet piped complete as directed with labour charge | Item 229 | ||
230 | 230 | ( I) 1000 litre capacity | Item 230 | ||
231 | 231 | (a) Sintex make | Item 231 | 1 | Each |
232 | 232 | Add 20% for works in Majuli Sub Division of Total Civil Works(Civil+Electrical+Water Supply) | Item 232 | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy