Overhauling And Maintenance Of 220Kv And 33Kv Switchyard And Transmission Line Of Cpp-Smelter , Intake Pump House And Ash Pond, CPP, NALCO, ANGUL-Odisha

National Aluminium Company Limited has published Overhauling And Maintenance Of 220Kv And 33Kv Switchyard And Transmission Line Of Cpp-Smelter , Intake Pump House And Ash Pond. Submission Date for this Tender is 31-12-2020. Electrical Products Tenders in CPP, NALCO, ANGUL Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

26124003
Corrigendum : Overhauling And Maintenance Of 220Kv And 33Kv Switchyard And Transmission Line Of Cpp-Smelter , Intake Pump House And Ash Pond
Tender
Indian
Odisha
Cpp, Nalco, Angul
31-12-2020

Tender Details

Overhauling And Maintenance Of 220Kv And 33Kv Switchyard And Transmission Line Of Cpp-Smelter , Intake Pump House And Ash Pond , 1A ) 220Kv Isolator Maintenance As Per Scope Of Work , 1B ) 220Kv Breaker Maintenance As Per Scope Of Work , 1C ( I ) Tightening Of Lightning Spike Stru , As Per Scope Of Work , 1C ( Ii ) Tightning Of Structure 22 . 5Mtr Ht , As Per Scope Of Work , 1C ( Iii ) Tightning Of Structure 17 . 5Mtr Ht , As Per Scope Of Work , 1C ( Iv ) Tightning Of Structure 13 . 0Mtr Ht , As Per Scope Of Work , 1C ( V ) Tightning Of Structure Beam10 , 13 , 17 , As Per Scope Of Work , 1C ( Vi ) Tightening Of Isolator Structure7 . , As Per Scope Of Work , 1C ( Vii ) Tightening Of Ct Structure7 . 1Mtr As Per Scope Of Work , 1C ( Viii ) Tightning Of Bus Support Insulat , As Per Scope Of Work , 1C ( Ix ) Tightening Of Pt , Cvt , La , Bkr Struct , As Per Scope Of Work , 1C ( X ) Tightening Of La Structure 10Mtr Ht , As Per Scope Of Work , 1D ( I ) Tightness Checking Of Dbl Ten Clmp , As Per Scope Of Work , 1D ( Ii ) Tightness Checking Of Sin Ten Clmp , As Per Scope Of Work , 1D ( Iii ) Tightness Checking Of Dbl Susp Cl , As Per Scope Of Work , 1D ( Iv ) Tightness Checking Of Sing Susp Cl , As Per Scope Of Work , 1D ( V ) Tightness Checking Of Pg Clmp , As Per Scope Of Work , 1D ( Vi ) Tightness Checking Of Ear Wire Ten , As Per Scope Of Work , 1D ( Vii ) Tightness Checking Of Bus Drpr Cl , As Per Scope Of Work , 1D ( Viii ) Tightness Checking Of Bus Drpr C , As Per Scope Of Work , 1D ( Ix ) Tightness Checking Of Bkr Clamp , As Per Scope Of Work , 1D ( X ) Tightness Checking Of Ct , Pt , Cvt , La , As Per Scope Of Work , 1D ( Xi ) Tightness Checking Of Wave Trap Cl , As Per Scope Of Work , 1D ( Xii ) Tightness Checking Of Spacer Clmp , As Per Scope Of Work , 1D ( Xiii ) Tightness Checking Of Bus Sup Cl , As Per Scope Of Work , 1D ( Xiv ) Tightness Checking Of Al Tube St , As Per Scope Of Work , 1D ( Xv ) 220Kv 3Ph Shorting & Normalisation , As Per Scope Of Work , 2 ( I ) Alignment Of 220Kv Isolator , As Per Scope Of Work , 2 ( Ii ) Replacement Of 220Kv Isol Polycon , As Per Scope Of Work , 2 ( Iii ) Replacement Of 70-80 Od Al Bus , As Per Scope Of Work , 2 ( Iv ) Replacement Of Equip Clmp Ct , Pt , La , As Per Scope Of Work , 2 ( V ) Replacement Of Tension Clamp , As Per Scope Of Work , 2 ( Vi ) Replacement Of Suspension Clamp , As Per Scope Of Work , 2 ( Vii ) Stringing & Restringing Of Moose C , As Per Scope Of Work , 2 ( Viii ) Replacement Of 220Kv Pg Clamp , As Per Scope Of Work , 2 ( Ix ) Replacement Of Gi Nuts & Bolts , As Per Scope Of Work , 2 ( X ) Replacement Of Wave Trap , As Per Scope Of Work , 2 ( Xi ) Installation Of Gi Strips 50X6mm Or , As Per Scope Of Work , 2 ( Xii ) Installation Of Gi Strips Above 50 , As Per Scope Of Work , 2 ( Xiii ) Repairing Of Gi Strips 50X6mm Or , As Per Scope Of Work , 2 ( Xiv ) Painting Of Pnl With Enml Paint , As Per Scope Of Work , 2 ( Xv ) Refilling Of Sf-6 Gas , As Per Scope Of Work , 2 ( Xvi ) Dcrm Testing Of 220Kv Bkr , As Per Scope Of Work , 2 ( Xvii ) Tan-Delta Testing Of 220Kv Ct , Bus , As Per Scope Of Work , 2 ( Xviii ) Crm & Timing Meas Of 220Kv Bkr , As Per Scope Of Work , 2 ( Xix ) O/H Of 220Kv Breaker , As Per Scope Of Work , 2 ( Xx ) O/H Of Abb Breaker Ventile , As Per Scope Of Work , 2 ( Xxi ) Replacement Of Abb Bkr Ventile , As Per Scope Of Work , 2 ( Xxii ) O/H Of Abb Breaker Actuator , As Per Scope Of Work , 2 ( Xxiii ) O/H Of 220Kv Iso Mech G . Box , As Per Scope Of Work , 2 ( Xxiv ) Thermography Of Swrd Clamp & Conn , As Per Scope Of Work , 2 ( Xxv ) Earth Resistans Meas Of Earth Pit , As Per Scope Of Work , 2 ( Xxvi ) Healthiness Checking Of La , As Per Scope Of Work , 2 ( Xxvii ) Stringing/Restringing Of Shld Wi , As Per Scope Of Work , 2 ( Xxviii ) String/Restringing Of Earth Wir , As Per Scope Of Work , 3 ( I ) Maint . Of 220Kv Tension Tower , As Per Scope Of Work , 3 ( Ii ) Maint . Of 220Kv Normal Tower , As Per Scope Of Work , 4 ( I ) Replacement Of 220Kv Tens Insulator , As Per Scope Of Work , 4 ( Ii ) Replacement Of 220Kv Susp Insulator , As Per Scope Of Work , 4 ( Iii ) Replacement Of 220Kv Tr Rod . , As Per Scope Of Work , 4 ( Iv ) Replacement Of 220Kv Tension Clamp , As Per Scope Of Work , 4 ( V ) Replacement Of 220Kv Susp Clamp , As Per Scope Of Work , 5 ( I ) Painting Of Single Pole Incl Supply , As Per Scope Of Work , 5 ( Ii ) Painting Of Single Pole Excl Supply , As Per Scope Of Work , 5 ( Iii ) Painting Of Dp Including Supply , As Per Scope Of Work , 5 ( Iv ) Painting Of Dp Excluding Supply , As Per Scope Of Work , 5 ( V ) Painting Of Four Pole Exc Supply , As Per Scope Of Work , 5 ( Vi ) Maint . Of Singl Pole With Cut Point , As Per Scope Of Work , 5 ( Vii ) Maint Of Singl Pole Without Cut Po , As Per Scope Of Work , 5 ( Viii ) Maint Of 33Kv Dp Structure , As Per Scope Of Work , 5 ( Ix ) Maint Of Tower In Ash Pond Line , As Per Scope Of Work , 6 ( I ) Replacement Of 33Kv Disc Insulator , As Per Scope Of Work , 6 ( Ii ) Replacement Of 33Kv Pin Insulator , As Per Scope Of Work , 6 ( Iii ) Stringing Of O/H Line With Racoon , As Per Scope Of Work , 6 ( Iv ) 33Kv Mid Span Jointing Of Racoon , As Per Scope Of Work , 6 ( V ) Erection Of 200X100mm Rs Joist Pole , As Per Scope Of Work , 6 ( Vi ) Erection Of Dp For 33Kv Line , As Per Scope Of Work , 6 ( Vii ) Dismantling Of 200X100mm Rs Joist , As Per Scope Of Work , 6 ( Viii ) Installation Of Stay Incl Supply , As Per Scope Of Work , 6 ( Ix ) Repairing Of Stay Incl Replacement , As Per Scope Of Work , 6 ( X ) Dismantling Of Existing Stay Set , As Per Scope Of Work , 6 ( Xi ) Stringing/Restringing Of Guard Wire , As Per Scope Of Work , 6 ( Xii ) Installation & Commis Of Earth Pit , As Per Scope Of Work , 6 ( Xiii ) Repairing Of Pipe Earthing , As Per Scope Of Work , 6 ( Xiv ) Erection Of Coil Earthing , As Per Scope Of Work , 6 ( Xv ) Repairing Of Coil Earthing , As Per Scope Of Work , 6 ( Xvi ) Fabrication Of Ms Angl/Chnl/Flat , As Per Scope Of Work , 7 ( I ) Replacement Of V/Straight C Arm At C , As Per Scope Of Work , 7 ( Ii ) Replacement Of V/Straight C Arm St , As Per Scope Of Work , 7 ( Iii ) Replacement Of Top Chnl At C Point , As Per Scope Of Work , 7 ( Iv ) Replacement Of Top Chnl St R Point , As Per Scope Of Work , 7 ( V ) Replacement Of Cross Arm In Dp , As Per Scope Of Work , 7 ( Vi ) Dismantling & Restringing With Raco , As Per Scope Of Work , 8 ) Maint . Of 33Kv Swrd At Cpp/Iph/Ap , As Per Scope Of Work , 9 ( I ) Replacement Of 33Kv Post Insulator , As Per Scope Of Work , 9 ( Ii ) Replacement Of 33Kv Isol M Contact , As Per Scope Of Work , 9 ( Iii ) Replacement Of 33Kv Isol F Contact , As Per Scope Of Work , 9 ( Iv ) Alignment Of 33Kv Isolator , As Per Scope Of Work , 9 ( V ) Replacement Of 33Kv Disc Insulator , As Per Scope Of Work , 9 ( Vi ) Replacement Of 33Kv Pin Insulator , As Per Scope Of Work , 9 ( Vii ) Replacement Of 33Kv St Insl Hardwa , As Per Scope Of Work , 9 ( Viii ) Dismantling Of Dog/Racoon Conduct , As Per Scope Of Work , 9 ( Ix ) Replacement Of 33Kv Clamp/Connector , As Per Scope Of Work , 9 ( X ) Replacement Of Ct/Pt/La Jn Box , As Per Scope Of Work , 9 ( Xi ) Replacement Of Surge Counter , As Per Scope Of Work , 9 ( Xii ) Replacement Of 33Kv Drop Out Fuse , As Per Scope Of Work , 10 ) Maint . Of 6 . 6Kv Vcb At Cpp & Iph , As Per Scope Of Work , 11 ) Maint . Of 6 . 6Kv Board ( Section Wise ) , As Per Scope Of Work , 12 ( A ) Maint Of 6 . 6Kv Cap Bank , As Per Scope Of Work , 12 ( B1 ) Replacement Of Capacitor Unit , As Per Scope Of Work , 12 ( B2 ) Replacement Of 6 . 6 Kv La , As Per Scope Of Work , 12 ( B3 ) Replacement Of 6 . 6Kv Neutral Ct , As Per Scope Of Work , 12 ( B4 ) Replacement Of 6 . 6Kv Clamp/Connect , As Per Scope Of Work , 12 ( B5 ) Replacement Of 6 . 6Kv Isolator , As Per Scope Of Work , 12 ( B6 ) Alignment Of 6 . 6Kv Isolator , As Per Scope Of Work , 12 ( B7 ) Replacement Of 6 . 6 Kv Pt , As Per Scope Of Work , 12 ( B8 ) Replacement O

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-12-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document